Hybrid VRF Install Materials Hybrid Install Materials

Total Page:16

File Type:pdf, Size:1020Kb

Hybrid VRF Install Materials Hybrid Install Materials STÖRNCH Hybrid VRF Install Materials Hybrid Install Materials Hybrid Install Hybrid VRF www.greenmillac.com 01206 864 467 2 STÖRNCH Hybrid VRF STÖRNCH Hybrid VRF 3 Hybrid Contents Hybrid Introducing How does Hybrid VRF work? 4–5 STÖRNCH Hybrid MLC Barrier Pipe system 6 Hybrid MLC Barrier Pipe Press Fit system 7–12 STÖRNCH Hybrid VRF Hybrid RTM system 13–17 Hybrid Copper Press Fit system 18–21 Today’s buildings face stringent legislation, which means the utilisation of traditional HVAC technologies isn’t always Hybrid Components & Water supply 22–27 Hybrid VRF Hybrid VRF possible, or in fact the best solution. With regulations only getting stricter, manufacturers are being forced to Hybrid Tool - One Tool: Three systems 28–29 innovate. Against this backdrop, Mitsubishi have developed the Hybrid VRF system. ZoomLock Braze Free Press Fit system 30–35 STÖRNCH At Greenmill we place great store in innovation, consistently bringing new and unique products to market, which made the Hybrid system a perfect fit for us. We have been close to its introduction to the industry from the start, and are now able to offer extensive project support and advice on the various options. We stock an extensive range of Hybrid install materials, available for next day nationwide delivery to site, and also offer FREE onsite support visits. Partner with Greenmill for expert advice, resources and support for all your Hybrid installation project requirements. Smart-order online at: www.greenmillac.com 4 STÖRNCH Hybrid STÖRNCH Hybrid 5 Hybrid Hybrid How does Hybrid Branch Controller(HBC) Hybrid VRF work? At the heart of Hybrid VRF Put simply, Hybrid VRF is a 2-pipe heat recovery VRF with water between A STÖRNCH the Hybrid Branch Controller (HBC) and indoor units. You can install and B design it as VRF whilst enjoying the features of a Chiller system. Hybrid Providing a complete modern solution for office buildings, C Hybrid hotels, medical centres, schools, high rise buildings, A B shopping centres and other commercial premises. A. Plate Heat Exchangers This is the point where refrigerant circuit Connection to slave HBC STÖRNCH With water at the indoor units, Hybrid VRF provides comfortable transfers its energy to the sealed water system. and stable air temperature control with no refrigerant in There are two sets of plate heat exchangers, both Water flow / return to indoor units occupied spaces, meaning simple compliance to placed at opposite ends in the HBC box. 8 or 16 port options available BS EN378 and removing the need for Both sets provide hot water in heating mode or cold water in cooling mode. leak detection. HYBRID VRF During mixed mode, one set provides hot water while the System example other provides cold water to its respective flow header. Refrigerant pipes to outdoor unit, expansion tank (field supplied) and Central controllers B. Pumps water filling loop (field supplied). Each set of plate heat exchangers has a DC inverter driven water pump. VRF heat recovery This circulates the close loop water system outdoor unit between the HBC and indoor units. Water to indoor unit YLM air or The discharge flow rate from the pump is Refrigerant Heating Cooling water sourced controlled by the valve block. (22-56kW) Water piping providing C. Valve Block A C A B B 2 refrigerant pipes simultaneous heating A valve block is connected between each flow and return port of the HBC. and cooling Water to indoor unit This valve block has two features: firstly is has the HBC overview Refrigerant choice of selecting between the two flow headers (mixed mode) Hybrid Branch and secondly it controls the flow of the water sent Controller (HBC) to the indoor unit, defining the capacity. 8 or 16 ports Indoor Units Up to 50 indoor units ZoomLock and Hybrid Systems VRF heat recovery (1.7-5.0kW) outdoor unit HYBRID VRF Remote controllers ZoomLock is recommended for the jointing of the high pressure refrigeration copper from the VRF YLM air or key features & benefits water sourced unit to the Hybrid Branch Controller Box. From the (22-56kW) HBC to the units we are recommending jointing the Flexible application options No refrigerant in occupied spaces plumbing pipework using either the copper press or 2 refrigerant pipes plastic press system. Meets future requirements Manageable phased installation Fully packaged solution Simplified 2-pipe design & installation Hybrid Branch Controller (HBC) 8 or 16 ports Smart-order online at: www.greenmillac.com 6 STÖRNCH Hybrid Barrier Pipe STÖRNCH Hybrid Barrier Press Fit System 7 Hybrid Hybrid STÖRNCH HYBRID STÖRNCH Barrier Pipe Barrier Pipe Press System STÖRNCH Hybrid Barrier Press Fit System Hybrid Barrier Press Hybrid Barrier Pipe STÖRNCH PEX Outer Layer Adhesive Layer Aluminium Layer Combining the benefits of both plastic and metal Product benefits are obtained that cannot pipes, the STÖRNCH barrier pipe is a composite be surpassed: Adhesive Layer pipe comprised of 5 layers. It has an aluminium pipe at its core, with an inner and outer layer of high Simply bend by hand temperature resistant polyethylene. PEX Inner Layer Cut to length All layers are permanently bonded together by Bevelling means of an intermediate adhesive layer. A special welding technique guarantee’s maximum safety... Join together Press – done! The patented system means joints can be made literally in seconds, and eliminates the need for The basis of the system is Hybrid VRF complex practices like welding and soldering. simple, safe and fast pipe installation. Smart-order online at: www.greenmillac.com 8 STÖRNCH Hybrid Barrier Press Fit System STÖRNCH Hybrid Barrier Press Fit System 9 Hybrid Coiled Barrier Pipe Pre-Insulated Coiled Barrier Pipe Barrier Press Fit Straight Couplers Barrier Press Fit 90° Bends Hybrid STÖRNCH • For connecting 25mm Ø Barrier Pipe together • For connecting 25mm Ø Barrier Pipe together Part No Description Size Qty/Pk Part No Description Size Qty/Pk Fit System Hybrid Barrier Press • Multilayer pipe with aluminium GMUP1 Press Fit Straight Couplers 25mm Ø pk5 GMUP11 Press Fit 90° Bends 25mm Ø pk5 • WRAS approved • 50 year life expectancy • -40°C to +95°C working temperatures • Multilayer pipe with aluminium Barrier Press Fit Tee Barrier Press Fit Equal Tee • WRAS approved • 50 year life expectancy Part No Description Size Wall Size • -40°C to +95°C working temperatures GMUP110 Pre-insulated Coiled 25mm Ø x 9mm Barrier Pipe 50mt Part No Description Size Length GMUP120 Pre-insulated Coiled 25mm Ø x 13mm GMUP100 Coiled Barrier Pipe 25mm Ø 50mt Barrier Pipe 50mt Hybrid Barrier Press Fit System Hybrid Barrier Press • For connecting 25mm Ø Barrier Pipe to Hybrid Barrier Pipe Bevelling Tool products with a ¾" male thread • Used in conjunction with AAV's, drain off cocks, pressure gauges and manual STÖRNCH air vents • For connecting 25mm Ø Barrier Pipe together Part No Description Size Qty/Pk Part No Description Size Qty/Pk GMUP65 Press Fit Tees 25 x 25 x ½" FT pk5 GMUP31 Press Fit Equal Tees 25mm Ø pk10 Barrier Press Fit Male Adapter Barrier Press Fit Female Adapter • For bevelling of 25mm Ø Barrier Pipe • Not for use with RTM fittings • Handle can be removed for use in a • For connecting 25mm Ø Barrier Pipe to Hybrid fan coil units • For connecting 25mm Ø Barrier Pipe to fittings with ¾" male cordless drill threads such as ball valves Part No Description Size Part No Description Size Qty/Pk Part No Description Size Qty/Pk GMUP210 Barrier Pipe Bevelling Tool 25mm GMUP51 Press Fit Male Adapters 25mm Ø x3/4" Pk5 GMUP53 Press Fit Female 25mm Ø Pk5 Adapters x3/4" Smart-order online at: www.greenmillac.com 10 STÖRNCH Hybrid Barrier Press Fit System STÖRNCH Hybrid Barrier Press Fit System 11 Hybrid Copper Press Fit to Barrier Copper to Barrier Press Fit Air Admittance Valve Threaded Drain Off Cock Press Fit Adapter Compression Adapter Hybrid • Used as a popular way to come off the HBC stubs. STÖRNCH • Excellent for converting from 22mm copper pipe to 25mm Ø barrier pipe • Used for connecting 22mm copper tube to 25mm Ø barrier pipe • Usually one drain off cock is installed per fan coil We recommend using a GMCP2 22mm copper press fit coupling to • It has a compression fitting one end, and a press fit at the other • For releasing air from the Hybrid system unit on a Hybrid system connect this fitting to copper tube • • Install one AAV per fan coil unit at the higest point of the pipework • Screws into a female iron tee Part No Description Size Qty/Pk Part No Description Size Part No Description Size Part No Description Size Fit System Hybrid Barrier Press GMUP80 MLC Press Fit to 25mm Ø Pk5 GMHPF71 Copper to Barrier Press Fit / 22 to 25mm Copper Press Adapter x22mm Ø Compression Adapter GMHYAV15 Air Admittance Valve (AAV) ½" GMPC62 Threaded Drain Off Cock ½" Brass Compression Female Iron Coupler Barrier Press Fit Lever Ball Valves Outside Bending Spring Inside Bending Spring Hybrid Barrier Press Fit System Hybrid Barrier Press • Often used for connection to the Hybrid Branch Controller (HBC) • Used in conjunction with GMUP51 (25mm x ¾" Barrier Press Fit • Is used for isolating 25mm Ø Hybrid barrier pipework STÖRNCH Male Adapter & GMPPF65 25mm x ¾" RTM Male Adapter) Part No Description Size Part No Description Size GMUP41 Barrier Press Fit Lever Ball 25mm Ø GMPC214 Compression Female Coupler 22mm Ø x¾" Valve Copper Press Fit Male Threaded Adapter • For connecting 22mm copper pipe to the Hybrid fan coil unit • For bending 25mm Ø Barrier pipe externally • For bending 25mm Ø Barrier pipe internally Part No Description Size Qty/Pk Part No Description
Recommended publications
  • Installation and Technical Guide SEPTEMBER 2014 Worldwide Connections
    THE PUSH-FIT SOLUTION FOR UNDERFLOOR HEATING Includes this NEW addition: Installation and Technical Guide SEPTEMBER 2014 Worldwide Connections The John Guest Group has a long established reputation as a world leading manufacturer of push-fit fittings, tube and other fluid control products. A reputation built on producing consistently high quality products with an ongoing commitment to value engineering and product development. Quality Manufacture A commitment to quality is at the heart of the John Guest Philosophy The strictest control is maintained by virtue of the fact that design and manufacture is carried out in modern purpose built manufacturing centres in west London and at Maidenhead in Berkshire. Maintaining control over the whole process from initial tool design and tool making through to final assembly and testing ensuring that only products of the highest quality are produced. The company believe it is this commitment to quality that has led to it receiving prestigious awards from many of the world’s leading testing and approvals organisations. John Guest is a preferred supplier to many international companies. British Gas Service BS7291 No. KM39767 Speedfit PEX Fittings and Barrier Pipe. K24076, K24077 and K24078 2 The Speedfit System orf Underfloor 50ºC then distributed via a manifold A wide range of electrical components Heating has been designed to be as to heating circuits made using Speedfit means the system can have as much quick and easy as possible to install with Barrier Pipe. The temperature and control as required. component parts manufactured under an volume of water is altered to maintain ISO9001 Quality Management System.
    [Show full text]
  • Pipe World 2/2019
    THE UPONOR INFRA CUSTOMER MAGAZINE » ISSUE 2/2019 FISHGLOBE REVOLUTIONISES THE FUTURE OF PLASTIC STRUCTURES FOR MARINE CONDITIONS Page 6 SAFEGUARDING THE DRINKING WATER IN URBAN AREAS IS CRITICAL Page 8 FLOW MEASUREMENT REVEALS LEAKS IN THE WATER SUPPLY NETWORK Page 12 Dear reader, he water supply and wastewater infrastructure in many regions across Europe is ageing. Despite the high quality of drinking water in the Nordic countries, the condition of the old pipe networks poses challenges. For example, Tin Finland most of the network was built between 1960 and 1990 and in the biggest cities parts of the network are over 100 years old. According to a recent study in Finland (ROTI 2019), 12% of the sewer network and 12% of the potable water network has deteriorated and there is an increasing need to renovate the old networks to both ensure water quality and minimise water losses. In Finland, 68 million m3 of mains water is lost every year and a substantial part of this is due to leakages (SYKE 2018). In Sweden, the total leakage of clean drinking water is about 15% on average, corresponding to 99 million m3 (Svenskt Vatten 2019). This is not only a waste of clean drinking water – resources used to collect, treat and pump the drinking water are also wasted. Losses of water, and in issue 2/2019 particular leakages, are relevant for distribution network efficiency in all European countries. New innovations are needed to help solve these challenges. On p. 12, you can read about how our new Water Monitoring Services are helping the city of Pori in Finland to monitor 4 In Brief 16 Industrial its leakages.
    [Show full text]
  • INSULPEX™ Pre-Insulated Pexa Piping System
    Engineering progress Enhancing lives INSULPEX™ pre-insulated PEXa piping system Technical information which applies to the planning, design and installation of REHAU pre- insulated PEXa piping systems. na.rehau.com/resourcecenter TABLE OF CONTENTS 1 . Scope. .3 6 . System Design .........................14 6.1 .....Step 1: Determine Length .......................14 2 . Design Considerations ...................4 6.2 ....Step 2: Estimate Total Heat Loss . .14 6.3 ....Step 3: Estimate Flow Rate .....................15 3 . System Overview ........................5 6.4 ....Step 4: Determine Pipe Size. .15 3.1 .....System Advantages ............................5 6.5 ....Step 5: Calculate Heat Loss . .15 3.2 ....Application ...................................5 6.6 ....Step 6: Calculate Head Loss ....................16 4 . System Components .....................6 7 . System Testing .........................18 4.1 .....INSULPEX® Pipe ..............................6 4.2 ....SDR11 Compression-Sleeve Fitting ...............9 4.3 ....INSULPEX Insulation Kits .......................9 4.4 . INSULPEX Installation Accessories ..............10 4.5 ....RAUTOOL™ PEXa Pipe Installation Tools ..........10 5 . System Planning ........................11 5.1 .....Trench Installation ............................11 5.2 . Above-Ground Installation ......................12 5.3 ....Building Penetration ...........................12 5.4 . Thermal Expansion. .13 5.5 ....Transition to Building Service Piping ..............13 For updates to this publication and the most
    [Show full text]
  • John Guest Installation Guide
    Underfloor heating made simple Underfloor heating made simple About us 01 Why John Guest? 03 What makes JG Speedfit Underfloor different? 05 Working together with... 07 Underfloor heating explained 15 Reasons to install Speedfit Underfloor Heating 17 Understanding the system 19 Our underfloor heating collection 21 Project fundamentals 23 Choosing the right solution 24 Speedfit solutions at a glance 25 Screed floor solutions 29 Timber floor solutions 35 Existing floor solutions 39 Room Pack solutions 43 The smart way to control heat 45 Say hello to greater control 48 More choice. More style 49 Smart control on the move 51 Taking JG Aura to the next level 53 With you every step of the way 55 Underfloor heating made simple 57 Designing and pricing the perfect system 58 Get Inspired 59 About us Why John Guest? What makes JG Speedfit Underfloor different? Working together with... Why John Guest? When Mr John Guest opened his factory doors over half a century ago, his vision was to create a company offering great quality products and excellent customer service. Today, this ethos still rings true. John Guest’s reputation as a world-leading manufacturer of high quality, innovative, plastic push-fit connectors and pipe is still going strong. Five decades of engineering expertise John Guest was the first manufacturer of the push-fit fitting. With significant engineering expertise behind our push-fit concept, the uniqueness of our product lies within its high reliability of performance, longevity of service and ease of use. Maintaining control over the whole production process from product and tool design through to final assembly ensures our fittings, UFH products and pipe are of the highest standard, which has earned us global recognition as the industry benchmark.
    [Show full text]
  • Download PDF Version of This Issue
    CIPHEX WEST SIZING REFRIGERATION WHAT AM I? PREVIEW FOR WALK-IN COOLERS CONTEST LAUNCH HEATING SYSTEM TUNE UPS: TAKE THE EXTRA STEPS TO SAFETY, COMFORT & EFFICIENCY WHATEVER HAPPENED TO SOLAR THERMAL? GET THE MOST OUT OF HEAT THE HOWS AND WHYS EXCHANGERS OF REDUCED WATER CONSUMPTION OCTOBER 2016 HOW TO COUNTER THE EFFECTS OF THERMAL CHANGES Follow Us On Follow Us On @hpacmag @hpacmag THE BRADFORD WHITE® Residential eF Series® and LAARS® Mascot® LX Come see us at the CIPHEX WEST Trade Show Booth #737 Mascot® LX Combi Boiler Residential eF Series® Water Heater The Mascot LX is an all-in-one, wall-hung, space heating boiler This high efficiency, condensing power-vent water heater and tankless water heater available in seven sizes to meet the features a vertical, dual-pass heat exchanger system. smallest to largest home’s heating needs. It efficiently transfers It has a thermal efficiency of over 90% and a high recovery the most heat possible by using modern controls, a stainless steel to deliver an impressive amount of usable hot water. heat exchanger and efficient condensing design. Built to be the Best™ www.laars.com ©2016, Bradford White Corporation. All rights reserved. www.bradfordwhite.com 32935_Canada_Plumbing_HVAC_8125x1075.indd 1 9/19/16 2:37 PM HPAC_BradfordWhite_Oct.indd 1 2016-09-23 9:19 AM OCTOBER 2016 VOL. 90 NO. 6 TENTS 18 BEYOND THE WHAT AM I? FURNACE TUNE-UP 101 Welcome to the launch of HPAC’s What Am I? Pointers to help improve contest. Identify items, which will be featured overall comfort and efficiency in whole or in part and may be from any era, and customer relations.
    [Show full text]
  • L7180 (Heatlink Design Suite)
    ® Heat Link Design Suite 2.0 L7180 May 30, 2005 ® ® Heat Link Table of Contents Heat Link www.HeatLink.com Introduction.....................................................................................................................................3 Getting Started................................................................................................................................4 Design Suite Orientation ................................................................................................................7 HeatLink Start Menu.......................................................................................................................................8 Budget Menu .................................................................................................................................18 HeatLoss Menu..............................................................................................................................24 HeatLink HeatLink Design Suite Online Help/Guide ................................................................................30 HeatLink Design Suite Online Product Guide ...........................................................................31 Project Design Considerations.....................................................................................................33 HeatLoss Sheet ..............................................................................................................................35 Analysis Sheet................................................................................................................................51
    [Show full text]
  • National Museum of the United States Army
    National Museum of the United States Army na.rehau.com/projects Army museum enlists REHAU radiant system for climate control After more than 240 years of honorably serving the country, the U.S. Army is getting its own museum. Sited on a hilltop at Fort Belvoir in northern Virginia, the museum will occupy more than 80 acres of grounds and feature 185,000 ft² (17,187 m²) of exhibition and support space. Museum visitors will enter through a spacious lobby with a 35-ft (10.7-m) ceiling that features representations of the Army’s history. An engraved Honor Wall at the southern end of the lobby commemorates each of the battles fought in the Army’s history. The lobby leads to a vast, open exhibit hall – “Essentially, an airport hangar,” said Jason Calcagno, project manager during the museum’s construction for Southland Industries, the design- build company that served as the mechanical engineer for the project. Temperature control for the exhibit hall and the lobby is provided, in part, by a REHAU radiant heating and cooling system. Calcagno explains that this technology is ideal for this application, because the environment is controlled near the ground for visitor comfort, while energy is conserved by reducing the heating and cooling requirement in the air space higher up. A dedicated outdoor air system (DOAS) provides ventilation and humidity control. Combining radiant and DOAS for space conditioning significantly reduces the amount of HVAC energy, which in REHAU’s experience has been as much as 35 percent when compared to a standard forced-air system.
    [Show full text]
  • Direct Bury Pex Pipe
    Direct Bury Pex Pipe Earthshaking and superimposed Rik begemmed her blowers ruralizes or clue aimlessly. Ritchie often travesties hurryingly when picayune Millicent troubled mitotically and donating her diplegia. Uncleared Wilt sometimes gybe his brier nowhither and proselytising so bearishly! You earn be redirected once the validation is complete. Rhinoflex pex pipe is not allow retrofit connections with burying? Holes and piping? PTFE tape was a Zurn PEX CR fittings should dairy be exposed to cleaners, the tests could be performed with little additional construction expense. Crossover connections must be protected from freezing with pipe insulation. Long as pointed out big bucks when pex pipe you bury? If it gets that essential for that you, coal boilers, the pipe failure the joint might be anchored near the expansion joint to prevent junior from telescoping into such joint interest of the cinema of similar stack above each point. As practical length in direction in, to each lateral connections to avoid interference to its oxidative stability was heating solutions and it is on each of? Oxygen barrier pipe will thank on all systems so, then how will heed to sunset a soaker, you rely want him consider draining the habitat before winter. Has degrees in response notifications enabled or you bury pex tubing installation and other brands. And shock anyone comments, cutting, and appearance. It does not heated, cast terminal is definitely worth considering. Foam pipe is pex pipes will not useable the direction of piping heats and bury it works of? Position so i bury pex pipe and the direction in direct burial; the allen wrench supplied in.
    [Show full text]
  • 2903 Wavin Hep2o IG:Installer Guide
    Push-fit Plumbing System Installer Guide BS 7291 ED V T A RO C PP DU PRO July 2009 Contents Page Introduction 3 Introduction, Approvals 4 Features & Benefits, Installation 5 Performance, System Assembly Basics 6-7 Pipe Selection, Standard Pipe, Barrier Pipe, Pipe Specification, Straight Lengths, Coils 8-9 Pipe Cutting 10 Jointing Standard 11-12 Applications Sitework 13-15 Cabling through Joists 16-18 Pipe Support 18 Pipe Installation in Exposed Locations 18 Pipe Installation in Concealed Locations 19 Pipes through Walls and Floors 19 Laying of Pipe in Floor Screeds 19 Pipes Adjacent to Metalwork 19 Piping Noise Reduction 20 Manifolds/Microbore Plumbing 21 Underfloor Heating Pipe 22 Routabout 23 Conduit Systems 24-27 Installation Recommendations ® 28-29 Hep2O Within Dry Lined Walls ® 30 Hep2O Within Internal Drywall Systems ® 30-32 Hep2O Within Timber Framed and Steel Framed Buildings Compatability 33-41 Metric Copper Pipe, Using Compression, Fittings, Adjacent & Connections to Capillary Joints, Imperial Copper, Chrome Plated Copper or Stainless Steel Pipe, Incoming Service Pipe, Brass Spigots, Acorn System, Plastic Pipes, Steel pipes and Threaded Bosses, Connection to Appliances, Draw-off Taps, Ancillaries (Pumps, Valves, etc.), Storage Vessels and Radiators, Boilers and Heaters System 42-43 Fitting Detachment, Lubrication Modifications 44 Alterations General 45 Thermal Insulation Information 45 Freezing for Maintenance/System Modification ® 45 Painting Hep2O 45 Use of Corrrosion Inhibitors 45 Antifreeze 46 Electrical Safety 46 Woodworm/Timber
    [Show full text]
  • Plastics Pipe Plastikrohr Conduits En Plastique
    (19) TZZ_ZZ T (11) EP 1 708 880 B2 (12) NEW EUROPEAN PATENT SPECIFICATION After opposition procedure (45) Date of publication and mention (51) Int Cl.: of the opposition decision: B32B 27/32 (2006.01) C08L 23/04 (2006.01) 31.08.2016 Bulletin 2016/35 F16L 9/147 (2006.01) B32B 1/08 (2006.01) B29K 105/16 (2006.01) B29L 23/00 (2006.01) (2006.01) (2006.01) (45) Mention of the grant of the patent: B29C 47/00 B29C 47/02 (2006.01) (2006.01) 13.06.2012 Bulletin 2012/24 B29C 47/06 B29K 23/00 B29K 105/00 (2006.01) (21) Application number: 05702296.4 (86) International application number: PCT/IB2005/000134 (22) Date of filing: 20.01.2005 (87) International publication number: WO 2005/080077 (01.09.2005 Gazette 2005/35) (54) PLASTICS PIPE PLASTIKROHR CONDUITS EN PLASTIQUE (84) Designated Contracting States: (56) References cited: AT BE BG CH CY CZ DE DK EE ES FI FR GB GR EP-A- 0 174 611 EP-A- 1 216 823 HU IE IS IT LI LT LU MC NL PL PT RO SE SI SK TR EP-A1- 1 004 618 EP-A2- 1 216 823 DE-A1- 2 622 973 DE-A1- 10 064 336 (30) Priority: 20.01.2004 GB 0401183 DE-A1- 19 509 613 DE-A1- 19 853 545 US-A- 6 068 026 (43) Date of publication of application: 11.10.2006 Bulletin 2006/41 • Produktdatenblatt "Exxelor(TM) VA1801" • Produktdatenblatt "Ciba(R) Irganox(R) 245" (73) Proprietor: Uponor Innovation AB • Produktdatenblatt "LOTADER(R) AX 8900" 73061 Virsbo (SE) • Y.
    [Show full text]
  • UNDERFLOOR HEATING SYSTEMS Guidance Notes 02
    WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure and conduct heat to the surface of the floor. The heating pipe is the main component of the system. By using flexible pipes joined to a central manifold, continuous lengths can be installed within the floor structure without jointing. Underfloor heating systems provide an attractive alternative to radiators and other convective heating systems. They can easily be used in all types of modern floor construction. Underfloor heating is widely used in mainland Europe. In the UK, it is frequently used in commercial situations and luxury homes. Its benefits are increasingly accepted in housing developments and self-build applications. Benefits Underfloor heating creates an even surface temperature across the entire floor area within the building. Using the floor as the heating element frees wall and floor space for furniture, decorations and other uses. However, in utility rooms and bathrooms where radiators may be desirable (for airing clothes, etc.), they can be incorporated into the system and used in conjunction with the underfloor heating. Underfloor heating systems are safe and clean. As the floor is large in comparison with a normal wall mounted radiator, the system requires a much lower water temperature to achieve the same room temperature, eliminating the risk of burns and improving operating efficiencies. It reduces wasted heat at levels above head height which reduces running costs. As the systems generally operate with a flow temperature between 40°C to 50°C, the use of a condensing boiler can deliver efficiencies of up to 98%.
    [Show full text]
  • Product Catalogue 2019-20 Caldervale Technology Group
    Product Catalogue 2019-20 Caldervale Technology Group. Helping you make the right connections. Our Products Caldertech offers over 200 products for all your electrofusion and butt welding needs. Our core products include electrofusion and butt welding machines for connecting HDPE pipes, plus all associated tooling for preparing, clamping and maintaining pipe networks. In addition to our core products we offer a range of specialised tools for the water, gas and steel pipe industries. The majority of the products in this publication are designed and manufactured in the United Kingdom following the highest quality standards and safety regulations. Helping you make the right connections. Contents Contents Electrofusion Electrofusion Accessories 67 Welding Machines 03 Test + Calibration Equipment 68 Introduction 04 Output Leads 69 Do's and Don'ts 05 Terminal Ends + Adapters 70 CalderSafe Mobile 06 Barcode Scanners 71 Calder Nomad II 07 Miscellaneous 72 Calder Griffon + Calder Griffon HC 08 Calder Pegasus 09 Calder Pegasus HC 10 Butt Fusion Tooling 73 Connexion Blue 11 External Debeading Tools 74 SBOX Max 12 Internal Debeading Tools 75 Calder Centaur 13 Pipe Handling Tools 78 Calder Connexion Red 14 Calder Proxima 15 Calder Aquafuse AF160 16 Squeeze Off Tooling 79 Calder Aquafuse AF315 110v 17 Squeeze Tools 80 Calder Aquafuse AF315 18 Hydraulic Squeeze Tools 83 Electrical Input Plugs 19 Squeeze Off Tape 88 Butt Fusion Barrier Pipe Tooling 89 Welding Machines 21 ProtectaLine 90 Introduction 22 Puriton + ProFuse 92 Do's and Don'ts 23 Gator 2 24
    [Show full text]