Quality Increasing by Using High Precision Inclination Measurement

Total Page:16

File Type:pdf, Size:1020Kb

Quality Increasing by Using High Precision Inclination Measurement QUALITY INCREASING BY USING HIGH PRECISION INCLINATION MEASUREMENT In the focus: BlueSYSTEM - ZEROMATIC - MT-SOFT Version 2012/13 Edition 3 WYLER AG, Neigungsmesssysteme Im Hölderli 13, CH - 8405 WINTERTHUR (Switzerland) Tel. +41 (0) 52 233 66 66 Fax +41 (0) 52 233 20 53 E-Mail: [email protected] Web: www.wylerag.com QUALITY INCREASING BY USING HIGH PRECISION INCLINATION MEASUREMENT WYLER AG has a tradition of more than 75 Years in the Milestones WYLER AG field of inclination measurement. Grace to the use of 1970 / The development of the first electro- most modern technologies and the consequent deve- nic inclination measuring instrument NIV- lopment of new products WYLER AG has an interna- ELTRONIC was done in close co-operation tional reputation as a leading company for inclination with the company TESA in Renens, Swit- measuring equipment and systems. The product range zerland. Still today this instrument is highly starts from simple spirit levels to complex electronic esteemed by a number of metrologists. measuring systems. 1977 / Development and introduction of the In ancient times angular measurement was used for handheld instrument MINILEVEL “classic” A10 and the LEVELTRONIC “classic” A40, construction of buildings, the layout of maps and na- based on the capacitive measuring principle. turally for navigation purposes at sea. The instruments were rather insufficient and only the development of 1987 / Successful launching of the small new materials and manuf- handheld instrument CLINOTRONIC with acturing processes allowed which the name WYLER was increasingly to build more precise instru- spread into the whole world. ments. The manufacturing of the first Sextant in the Year 1995 / Presentation of the first inclination 1727 according to ideas of measuring sensor ZEROTRONIC, working Isaac Newton, the English completely on the digital principle together physic and astronomer, and with the corresponding software DYNAM. the production of the first Theodolyte by the physic 1996 / Development and introduction of Dollond in the Year 1760 are the new generation of handheld precision milestones in the history of measuring instruments MINILEVEL “NT” angular measurements. A11 and LEVELTRONIC “NT” A41 as succes- sors of the classic series instruments. Sir Isaac NEWTON 1642 - 1727 1997 / Development and launching of the Even today the technical life new type of handheld instrument named is unthinkable without the angular measurement. Espe- CLINO 2000 with integrated calibration cially in the quality assurance the inclination measure- possibility. ment, a special field of the angular measurement, is applied in all kind of different variations. An inclination 1998 / New development and marketing measuring instrument is used for measuring angles as of the spirit level series “SPIRIT” with a well as for measuring flatness of lines and surfaces. completely new revolutionary adjustment Also long term monitoring of angular deviation is a large system. field of applications. 2000 / Development of a wireless signal transmission of the measured data from the The classic spirit level used for many Years by the en- measuring instrument to a remotely placed gineers when constructing buildings, bridges or large receiver unit. machines is continuously replaced by electronic instru- ments. The main reason is, that these are more precise 2000 / Development and introduction to the and reliable in different market of the Software LEVELSOFT PRO. surroundings, supply more resolution, shorter reaction time and data for 2004 / Development of the 2–dimensional protocols and transfers. precision inclination sensors with automatic reversal measurement ZEROMATIC 2/1 and The latest development ZEROMATIC 2/2. clearly tends toward inc- lination sensors used in a 2005 / Development and introduction to the network of all kind of sen- market of the new Software MT-SOFT for sors where the measured definition of machine tool geometry. data can be transmitted Theodolyte von over short or long dis- 2005 / Development and introduction to the W. & S. Jones / 1890 tance and supplied to a market of the electronic inclination measu- data collecting device ring instruments BlueSYSTEM, with such as a computer or a manual read out instrument BlueLEVEL, BlueMETER and BlueTC. (Levelmeter). WYLER AG combines sensors, precision measuring technology and system solutions in the field of inclination measurement. We produce added value through proven advanced technology and well-founded application know how. 3 QUALITY INCREASING BY USING HIGH PRECISION INCLINATION MEASUREMENT 1. INTRODUCTION 2. APPLICATIONS AND OPERATIONAL AREAS OF INCLINATION MEASURING On all products, the requirements regarding quality and cost effectiveness and therefore on the manufacturing TECHNIQUES processes, are constantly increasing. In order to keep up with these requirements, new production methods and The inclination measuring instruments and systems are machines must be developed. At the same time the de- widely used for „MEASURING / ADJUSTING / MONITO- velopment of test methods and test equipment must be RING“ (Overview see next page): accelerated. • Measurement of straightness and flatness of ob- Since the foundation of the company in 1928, WYLER AG jects, e.g. surface plates and straight edges made in Winterthur, Switzerland was eager to fulfill the demand of granite of the market and to satisfy the worldwide clientele with • Measurement of machine tools; comparison of the supply of high quality inclination measuring equip- different measurements performed e.g. compari- ment. son between a horizontal guide way and a vertical spindle The field of angular detection and measurement is exten- • Measurement of printing machines and lineup sive and complex. A great number of different instruments support and processes have been developed to produce suitable • Calibration of industry robots results to fulfill the requirements, for instance; sine-bars, • Calibration of large radar stations sine tables, theodolytes, autocollimators, laser interfero- • Monitoring of objects such as bridges, dams, meters etc. This brochure concentrates on the inclination buildings etc. measuring instruments and systems of WYLER AG. The measuring instruments and system are getting more This document is intended to give an overview of the de- and more accurate. Despite the user friendly design and velopment in the area of the inclination measurement of the well documented user guide the demands on the the past decades. The emphasis is on the newest pro- user are increasing. Considering this, it is quite clear that ducts, requiring the most modern manufacturing techno- the training of the user in handling the instruments and logy, by using high tech materials and the application of systems is getting increasingly important. What’s the use microelectronics. of an excellent instrument when this is not suited for the task? Looking from the application’s point of view three diffe- What is the resolution range of the WYLER incli- rent options are basically available: nation measuring instruments? Besides the commonly used units, such as e.g. a. RELATIVE MEASUREMENT • Degrees / Arcminutes / Arcseconds • Radiant, mRadiant, µRadiant Measuring the flatness of an object, such as e.g. a granite • etc surface plate, it is quite important to set the plate horizon- tally. For the measurement of the surface it is, however, Arcseconds and µm/m are used for very small incli- important to look nations. The latest generation of inclination measu- only at the diffe- ring instruments and sensors has the ability to pro- rence between duce a resolution of <1 µm/m. the individual measurement It is difficult to visualize an angle of <1 µm/m. By multi- steps. In other plying the length „L“ and the height „H“ with the factor words it is for 1000 the relations of the triangle remain intact. This such a particular means measurement of now importance to receive the 1 µm/m is corresponding to 1 mm/km result in an ab- solute value (deviation from centre of the earth). These measurements may be done comfortably with the soft- ware LEVELSOFT PRO. After the measurement the re- H = 1 µm sults may be analyzed and aligned according to different tan a = H/L = 1 µm/m methods such as: I. Alignment according to the method “Endpoints” a II. Alignment according to the method “ISO 1101” L = 1 m III. Alignment according to the method “linear Regression” 4 QUALITY INCREASING BY USING HIGH PRECISION INCLINATION MEASUREMENT APPLICATIONS WITH WYLER INCLINATION MEASURING INSTRUMENTS Calibration Monitoring dams Monitoring of bridges Measuring and calibrating of radar stations MEASUREMENT ADJUSTMENT MONITORING Measuring and calibrating of industrial robots Measuring and adjustment of machine tools Measurement of high speed printing machines Measurement of flatness Monitoring of buildings 5 QUALITY INCREASING BY USING HIGH PRECISION INCLINATION MEASUREMENT Especially well suited for such measurements are the WYLER handheld instruments MINILEVEL NT and LEVELTRONIC NT or the latest instrument’s generation called BlueSYSTEM. For measurements in the absolute mode a number of dif- ferent inclination instruments and sensors are available. I. Handheld instruments MINILEVEL NT and LEVELTRONIC NT or the latest instrument’s generation called BlueSYSTEM with wireless data transmission as Here after you find a schematic view of a measuring set- described under “Relative measurements” are well sui- up with two BlueLEVELs and a BlueMETER linked to a PC ted for the measurements on machine tool
Recommended publications
  • 244LD Levelstar Intelligent Buoyancy Transmitter for Level
    Master Instruction 11.2016 MI EML0710 G-(en) 244LD LevelStar Intelligent Buoyancy Transmitter for Vers. 6.2.x Level, Interface and Density with Torque Tube and displacer – HART and Foundation Fieldbus – The intelligent transmitter 244LD LevelStar is designed to perform continuous measurements for liquid level, interface or density of liquids in the process of all industrial applications. The measurement is based on the proven Archimedes buoyancy principle and thus extremely robust and durable. Measuring values can be transferred analog and digital. Digital communication facilitates complete operation and configuration via PC or control system. Despite extreme temperatures, high process pressure and corrosive liquids, the 244LD measures with consistent reliability and high precision. It is approved for installations in contact with explosive atmospheres. The 244LD combines the abundant experience of FOXBORO with most advanced digital technology. FEATURES • HART Communication, 4 to 20 mA, or • Backdocumentation of measuring point Foundation Fieldbus • Continuous self-diagnostics, Status and diagnostic • Configuration via FDT-DTM messages • Multilingual full text graphic LCD • Configurable safety value • IR communication as a standard • Local display in %, mA or physical units • Easy adaptation to the measuring point • Process temperature from –196 °C to +500 °C without calibration at the workshop • Materials for use with aggressive media • Linear or customized characteristic • Micro sintermetal sensor technology • 32 point linearisation
    [Show full text]
  • IQ Sensornet Nitravis 701 & 705 IQ Sensors User Manual
    OPERATIONS MANUAL ba76078e03 05/2017 NitraVis 701 IQ NitraVis 705 IQ OPTICAL SENSOR FOR NITRATE NitraVis 70x IQ Contact YSI 1725 Brannum Lane Yellow Springs, OH 45387 USA Tel: +1 937-767-7241 800-765-4974 Email: [email protected] Internet: www.ysi.com Copyright © 2017 Xylem Inc. 2 ba76078e03 05/2017 NitraVis 70x IQ Contents Contents 1 Overview . 5 1.1 How to use this component operating manual . 5 1.2 Field of application . 6 1.3 Measuring principle of the sensor NitraVis 70x IQ . 6 1.4 Structure of the sensor NitraVis 70x IQ . 7 2 Safety . 8 2.1 Safety information . 8 2.1.1 Safety information in the operating manual . 8 2.1.2 Safety signs on the product . 8 2.1.3 Further documents providing safety information . 8 2.2 Safe operation . 9 2.2.1 Authorized use . 9 2.2.2 Requirements for safe operation . 9 2.2.3 Unauthorized use . 9 3 Commissioning . 10 3.1 IQ SENSORNET system requirements . 10 3.2 Scope of delivery of the NitraVis 70x IQ . 10 3.3 Installation . 11 3.3.1 Mounting the sensor . 11 3.3.2 Mounting the shock protectors . 13 3.3.3 Connecting the sensor to the IQ SENSORNET . 14 3.4 Initial commissioning . 16 3.4.1 General information . 16 3.4.2 Settings . 17 4 Measurement / Operation . 21 4.1 Determination of measured values . 21 4.2 Measurement operation . 22 4.3 Calibration . 22 4.3.1 Overview . 22 4.3.2 User calibration . 25 4.3.3 Sensor check/Zero adjustment .
    [Show full text]
  • Industrial Measuring Devices a Passion for Precision
    Industrial Measuring Devices A Passion for Precision a passion for precision · passion pour la précision · pasión por la precisión · passione per la precisione · a passion for precision · passion pour la précision · pasión por la precisión · www.lufft.com Measure and record data easily and precisely. Quality made in Germany without compromises. PalmPrecision in the of your Hand The highly demanding and complex measuring tasks of today can only be mastered with high-precision devices. The special requirements placed on hand-held measuring devices are the result of the spectrum of physical measurements that are to be measured, as well as the decisions that are based on this measured data. Architects, specialists and surveyors, engineers, climate experts and many other professionals bear the responsibility for people, technology, goods and processes. Whether you are investigating or recording the temperature of a surface without contact, the dew point temperature of air on walls, the moisture content of oil, air pressure or air fl ow, Lufft hand-held devices are easy to operate and – above all – precise! The XA1000 hand-held-measuring device is an all-round device that ful ls the highest demands. Various high-precision climatic measuring technology sensors can be alternatively connected. The measurement results are displayed in high resolution colour displays both in graphic and numeric formats. The integrated data re- corder allows the measurement results to be transferred to a computer; for this purpose the Lufft software Smart- Graph3 is ready and waiting. The XP Series consists of hand-held measuring de- The Software vices for specialists. The highest temperature precision SmartGraph3 manages and les measured data from combined with the most modern handling of measured both hand-held measuring devices and dataloggers.
    [Show full text]
  • An Overview of Particulate Matter Measurement Instruments
    Atmosphere 2015, 6, 1327-1345; doi:10.3390/atmos6091327 OPEN ACCESS atmosphere ISSN 2073-4433 www.mdpi.com/journal/atmosphere Review An Overview of Particulate Matter Measurement Instruments Simone Simões Amaral 1, João Andrade de Carvalho Jr. 1,*, Maria Angélica Martins Costa 2 and Cleverson Pinheiro 3 1 Department of Energy, UNESP—Univ Estadual Paulista, Guaratinguetá , SP 12516-410, Brazil; E-Mail: [email protected] 2 Department of Biochemistry and Chemical Technology, Institute of Chemistry, UNESP—Univ Estadual Paulista, Araraquara, SP 14800-060, Brazil; E-Mail: [email protected] 3 Department of Logistic, Federal Institute of Education, Science and Technology of São Paulo, Jacareí, SP 12322-030, Brazil; E-Mail: [email protected] * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +55-12-3123-2838; Fax: +55-12-3123-2835. Academic Editor: Pasquale Avino Received: 27 June 2015 / Accepted: 1 September 2015 / Published: 9 September 2015 Abstract: This review article presents an overview of instruments available on the market for measurement of particulate matter. The main instruments and methods of measuring concentration (gravimetric, optical, and microbalance) and size distribution Scanning Mobility Particle Sizer (SMPS), Electrical Low Pressure Impactor (ELPI), and others were described and compared. The aim of this work was to help researchers choose the most suitable equipment to measure particulate matter. When choosing a measuring instrument, a researcher must clearly define the purpose of the study and determine whether it meets the main specifications of the equipment. ELPI and SMPS are the suitable devices for measuring fine particles; the ELPI works in real time.
    [Show full text]
  • Electronic Pressure Measurement
    VERLAG MODERNE INDUSTRIE Electronic Pressure Measurement Basics, applications and instrument selection Electronic Pressure Measurement 889539 +Wika_Umschlag_5c_englisch.indd 1 11.02.2010 12:40:55 Uhr verlag moderne industrie Electronic Pressure Measurement Basics, applications and instrument selection Eugen Gaßmann, Anna Gries +Wika_Umbruch_eng.indd 1 11.02.2010 12:52:33 Uhr This book was produced with the technical collaboration of WIKA Alexander Wiegand SE & Co. KG. The authors would like to extend their particular thanks for the careful checking of the book’s contents to Dr Franz-Josef Lohmeier. Translation: RKT Übersetzungs- und Dokumentations-GmbH, Schramberg © 2010 All rights reserved with Süddeutscher Verlag onpact GmbH, 81677 Munich www.sv-onpact.de First published in Germany in the series Die Bibliothek der Technik Original title: Elektronische Druckmesstechnik © 2009 by Süddeutscher Verlag onpact GmbH Illustrations: No. 19 Phoenix Testlab GmbH, Blomberg; No. 22 M+W Zander, Stuttgart; all others WIKA Alexander Wiegand SE & Co. KG, Klingenberg Typesetting: abavo GmbH, 86807 Buchloe Printing and binding: Sellier Druck GmbH, 85354 Freising Printed in Germany 889539 +Wika_Umbruch_eng.indd 2 11.02.2010 12:52:34 Uhr Contents Introduction 4 Pressure and pressure measurement 6 International pressure units ..................................................................... 6 Absolute, gauge and differential pressure ............................................... 7 Principles of electronic pressure measurement ......................................
    [Show full text]
  • IQ Sensornet Carbovis 701 & 705 IQ Sensors User Manual
    OPERATIONS MANUAL ba76080e03 05/2017 CarboVis 701 IQ CarboVis 705 IQ OPTICAL SENSOR FOR CARBON SUM PARAMETERS CarboVis 70x IQ Contact YSI 1725 Brannum Lane Yellow Springs, OH 45387 USA Tel: +1 937-767-7241 800-765-4974 Email: [email protected] Internet: www.ysi.com Copyright © 2017 Xylem Inc. 2 ba76080e03 05/2017 CarboVis 70x IQ Contents Contents 1 Overview . 5 1.1 How to use this component operating manual . 5 1.2 Field of application . 6 1.3 Measuring principle of the sensor CarboVis 70x IQ . 6 1.4 Structure of the sensor CarboVis 70x IQ . 7 2 Safety . 8 2.1 Safety information . 8 2.1.1 Safety information in the operating manual . 8 2.1.2 Safety signs on the product . 8 2.1.3 Further documents providing safety information . 8 2.2 Safe operation . 9 2.2.1 Authorized use . 9 2.2.2 Requirements for safe operation . 9 2.2.3 Unauthorized use . 9 3 Commissioning . 10 3.1 IQ SENSORNET system requirements . 10 3.2 Scope of delivery of the CarboVis 70x IQ . 10 3.3 Installation . 11 3.3.1 Mounting the sensor . 11 3.3.2 Mounting the shock protectors . 13 3.3.3 Connecting the sensor to the IQ SENSORNET . 14 3.4 Initial commissioning . 16 3.4.1 General information . 16 3.4.2 Sensor structure . 17 3.4.3 Settings for the main sensor . 18 3.4.4 Settings for virtual sensors . 21 4 Measurement / Operation . 23 4.1 Determination of measured values . 23 4.2 Measurement operation .
    [Show full text]
  • Thermodynamic Speed of Sound Data for Liquid and Supercritical Alcohols
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by DepositOnce Muhammad Ali Javed, Elmar Baumhögger, Jadran Vrabec Thermodynamic Speed of Sound Data for Liquid and Supercritical Alcohols Journal article | Accepted manuscript (Postprint) This version is available at https://doi.org/10.14279/depositonce-8387 Javed, Muhammad Ali; Baumhögger, Elmar; Vrabec, Jadran (2019). Thermodynamic Speed of Sound Data for Liquid and Supercritical Alcohols. Journal of Chemical & Engineering Data, 64(3), 1035–1044. https://doi.org/10.1021/acs.jced.8b00938 Terms of Use Copyright applies. A non-exclusive, non-transferable and limited right to use is granted. This document is intended solely for personal, non-commercial use. Thermodynamic speed of sound data for liquid and supercritical alcohols Muhammad Ali Javed┼, Elmar Baumhögger┴, Jadran Vrabec┼* ┼ Thermodynamics and Process Engineering, Technical University of Berlin, 10623 Berlin, Germany ┴ Thermodynamics and Energy Technology, University of Paderborn, 33098 Paderborn, Germany ABSTRACT: Because of their caloric and thermal nature, speed of sound data are vital for the development of fundamental Helm- holtz energy equations of state for fluids. The present work reports such data for methanol, 1-propanol, 2-propanol and 1-butanol along seven isotherms in the temperature range from 220 K to 500 K and a pressure of up to 125 MPa. The overall expanded uncer- tainty varies between 0.07% and 0.11% with a confidence level of 95%. The employed experiment is based on a double path length pulse-echo method with a single piezoelectric quartz crystal of 8 MHz, which is placed between two reflectors at different path- lengths.
    [Show full text]
  • Anesthesia Gas Monitoring: Evolution of a De Facto Standard of Care
    Anesthesia Gas Monitoring: Introduction The overriding concern for patient safety during surgery Evolution of a de facto has given rise to the development and adoption of a num- ber of technologies, whose use is taken for granted every Standard of Care time a patient undergoes general anesthesia. These tech- nologies include airway pressure monitoring and breath- ing system disconnect alarms, monitoring of inspired oxy- gen, monitoring of expired CO2, and pulse oximetry. The ongoing technical advancements in the field of respiratory gas monitoring of the five potent inhaled anesthetic agents, N2O, CO2 and O2; the valuable information they provide to the anesthesia caregiver, the shrinking of the physical attributes (i.e. size and weight) of these sensors and mon- itors, and their lower purchase cost, has seen their use in most modern operating rooms in the world. The feedback they provide to the clinician has become an indispensible tool designed to ensure the patient’s safety during the peri- operative period. Monitoring the anesthetic gases deliv- ered by the anesthesia delivery system can alert the care- giver to a number of potentially adverse conditions such as inadvertent agent overdose, timing to reach MAC awake (pseudo awareness detection), error of a vaporizer filled with incorrect agent, monitoring of uptake and distribution, and assurance that the desired agent concentration is being delivered, especially when low flow anesthesia is administered. 1 In his ASA refresher course, Hazards of the Anesthesia Workstation, Dr. James Eisenkraft, Professor of Anesthe- siology at the Mount Sinai School of Medicine, in New York City, points out that hardware failures in modern anesthe- sia delivery equipment are rare.
    [Show full text]
  • Alternating Current
    j271 Index a Artifacts 245f AC (alternating current) calorimeter 194f, Artificial nose 225 217 Accelerating rate calorimeter (ARC) 198, 204 b Accuracy 133, 233ff Bacteria 2, 259ff Activation energy 39, 110, 264 Balances 19 – phase transition 39 Baseline 91ff, 98, 113, 121 Active measuring system 74 – DSC 98 Activity monitor 159f – drift 160, 231f Actual value (controller) 128 – stability 242 Adiabatic – step change 71, 98, 159 – calorimeter 68, 73, 75f, 77, 190 Battery calorimeter 160 ––measured curve 86f Berthelot bomb 45, 58, 148 – calorimetry 68 Binary system 54f – condition 75f Biological studies 2, 10, 13, 82, 160, 186, 212, – flow calorimeter 199 225, 256ff – reaction calorimeter 198, 204 – smearing of the measured curve 82 – scanning calorimeter 200 Boersma method 181 – scanning condition 77 Boiling curve 55 – whole body calorimeter 169, 199 Boiling point 55 Alternating current (AC) calorimeter 194f, Bomb calorimeter 132, 150 217 Books on calorimetry 4 Aluminum (heat capacity) 197 Boundary conditions 31f, 38, 40, 44f, 56, 59 Ammonia (gas-liquid transition) 138 Bronsted€ method 12 Amount of substance, measurement 19 Bunsen ice calorimeter 10, 135 Aneroid 13 – calorimeter 151 c Animal 10, 169, 256ff Calibration 14, 15, 19f, 140, 146f, 155, 158, Aperiodic limit (controller) 130 163, 175, 188, 200, 239ff Apparatus function 103, 105, 106, 169, 189, – enthalpy 241 232, 234, 243 – factor 14, 97, 98f, 119, 154f, 157, 164, 170, – Calvet calorimeter 166, 169 173, 180f – fluctuations 107 – flow calorimeter 170 – measurement 106 – heat 239ff Application of calorimetry 2f, 246ff – heat flow calorimeter 157f Approximation, reversible 41 – heat flow rate 224f, 239ff ARC (accelerating rate calorimeter) 198, – material 241f 204 – temperature 239, 241 Arrhenius equation 110f Caloric problems 246ff Calorimetry: Fundamentals, Instrumentation and Applications, First Edition.
    [Show full text]
  • Experimental Method
    See discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/267337818 Measurement of density using oscillation-type density meters. Calibration, traceability and Uncertainties Conference Paper · June 2009 CITATIONS READS 4 4,975 4 authors, including: Andreia Furtado Elsa Batista Instituto Português da Qualidade Instituto Português da Qualidade 41 PUBLICATIONS 80 CITATIONS 38 PUBLICATIONS 105 CITATIONS SEE PROFILE SEE PROFILE Eduarda Filipe Instituto Português da Qualidade 78 PUBLICATIONS 220 CITATIONS SEE PROFILE Some of the authors of this publication are also working on these related projects: rhoLiq View project tsetse phylogenetics and population genetics View project All content following this page was uploaded by Andreia Furtado on 27 October 2014. The user has requested enhancement of the downloaded file. MEASUREMENT OF DENSITY USING OSCILLATION-TYPE DENSITY METERS CALIBRATION, TRACEABILITY AND UNCERTAINTIES A. Furtado, E. Batista, I. Spohr, E. Filipe Instituto Português da Qualidade (IPQ) Rua António Gião, 2 – Caparica – Portugal [email protected] quality control of fuels and additives; in the chemical and Résumé nuclear, to determine the concentration of acids, bases and other solutions and to determine radioactive substances concentration; in the food industry, cosmetics, etc. La masse volumique d'un fluide peut être déterminé en utilisant plusieurs instruments de mesure. Récemment, les This magnitude can be determined using several densimètres à oscillations ont montré une grande measuring instruments, such as pycnometers, hydrometers polyvalence, ils sont utilisés en différentes branches de and oscillation-type density meters, and also using the l'industrie. Le Laboratoire des Propriétés des Liquides method of hydrostatic weighing. Recently the oscillation- (LPL) de l'Institut Portugais pour la Qualité (IPQ) réalise type density meters have shown great versatility, and are l'étalonnage de ces instruments par rapport à un étalon de being used in various branches of industry.
    [Show full text]
  • 244LVP Intelligent Buoyancy Transmitter for Liquid Level, Interface and Density
    Master Instruction 02.2010 MI EML1710A-(en) 244LVP Intelligent Buoyancy Transmitter for Liquid Level, Interface and Density The intelligent transmitter 244LVP is designed to perform continuous measurements for liquid level, interface or den- sity of liquids in the process of all industrial applications. The measurement is based on the proven Archimedes buoy- ancy principle and thus extremely robust and durable. Measuring values can be transferred analog and digital. Digital communication facilitates complete operation and configuration via PC or control system. The 244LVP measures with consistent reliability and high precision. For installations in contact with explosive atmospheres up to Zone 0, cer- tificates are available. The 244LVP combines the abundant experience of FOXBORO ECKARDT with most advan- ced digital technology. FEATURES • Communication HART (4-20 mA) • Local display in %, mA or physical units • Conventional operation with local keys • Signal noise suppression by Smart Smoothing • Easy adaptation to the measuring point • Continuous self-diagnostics without calibration at the workshop • Linear or customized characteristic • Backdocumentation of measuring point • Process temperature from –50 °C to +150 °C • Configurable safety value • Static pressure up to PN 40 • Software lock against unauthorized operation • Micro sintermetal sensor technology • Simulation of analog output for loop-check Repair and maintenance must be carried out by qualified personnel! 2 244LVP MI EML1710 A-(en) CONTENTS CHP. CONTENTS PAGE 1 DESIGN 3 2
    [Show full text]
  • Measuring Techniques in Gas–Liquid and Gas–Liquid–Solid Reactors Christophe Boyera;∗, Anne-Marie Duquenneb, Gabriel Wildc
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Open Archive Toulouse Archive Ouverte Open Archive TOULOUSE Archive Ouverte ( OATAO ) OATAO is an open access repository that collects the work of Toulouse researchers and makes it freely available over the web where possible. This is an author-deposited version published in : http://oatao.univ-toulouse.fr/ Eprints ID : 16521 To link to this article : DOI : 10.1016/S0009-2509(02)00193-8 URL : http://dx.doi.org/10.1016/S0009-2509(02)00193-8 To cite this version : Boyer, Cristophe and Billet, Anne-Marie and Wild, Gabriel Measuring techniques in gas–liquid and gas–liquid– solid reactors. (2002) Chemical Engineering Science, vol. 57 (n° 16). pp. 3185-3215. ISSN 0009-2509 Any correspondence concerning this service should be sent to the repository administrator: [email protected] Measuring techniques in gas–liquid and gas–liquid–solid reactors Christophe Boyera;∗, Anne-Marie Duquenneb, Gabriel Wildc aCentre d’etudes et de developpement industriels (CEDI) “Rene Navarre” BP no 3, F 69390, Vernaison France bLaboratoire de Genie Chimique, ENSIACET—CNRS (UMR no 5503) 18 chemin de la Loge, F 31078 Toulouse cedex 04, France cLaboratoire des Sciences du Genie Chimique, CNRS (UPR no 6811)—ENSIC, B.P. 451, F 54001 Nancy, France Abstract This article o ers an overview of the instrumentation techniques developed for multiphase ow analysis either in gas/liquid or in gas/liquid/solid reactors. To characterise properly such reactors, experimental data have to be acquired at di erent space scale or time frequency.
    [Show full text]