<<

Technical Info

Modified Cover Material 220 - 240V / 50Hz

In the latest standard “Safety of Therefore, will change In case of the standard Ultramid household and similar electrical the material of the cover in con- cover (code no. 103N2010) for TL, appliances, IEC60335-1, Edition 4” nection with our TL, NL, and FR NL, and FR it is permissible that an the flammability safety demands compressors for 220-240V/50Hz inside electrical connection touch- have been changed. operation from Capron 8202 to es the cover. However, there has This new standard becomes Ultramid B3S and in connection to be a certain free space outside effective in EU (EN 60335-1) from with our PL, TF, NF, FF, and SC the cover (ø 20x50 mm to electrical October 2005 for light commercial compressors for 220-240V/50Hz connections). If this is not the case, appliances and from October operation to Noryl SE1. the “disturbing” external part has 2006 for household appliances. The change of material will take to be of non-flammable material or Other countries can have different place by the end of September it has to be able to pass the needle schedules. 2005 at the latest. flame test. Danfoss will change the cover material according to the table to 220 - 240V / 50Hz Material comply with this new standard. type Cover code no. Today New The cover code nos. will not be PL 103N0491 Capron 8202 Noryl SE1*** changed. Standard = 103N2010 Capron 8202 Ultramid B3S** TL, NL, FR Our existing Capron 8202 covers Special = 103N2011 Noryl SE1*** would normally (e .g. with PTC in a TF, NF, SF 117U1023 Capron 8202 Noryl SE1*** household appliance) comply with SC 103N2009 Capron 8202 Noryl SE1*** this new standard. Generally, this Terminal board* 117U1022 Capron 8202 Noryl SE1*** material is acceptable if electrical The Noryl cover 103N2011 has to be used if connections (≥0.2 Amps) under • Compressor and appliance have to be UL approved (e. g. for 220V 60Hz applications) or the cover are placed ≥ 3 mm from • Flammable parts are surrounding the cover, inside ø20x50 mm to electrical connections the cover. However, if e.g. a special (≥0.2 Amps) and an electrical connection is closer than 3 mm to the cover. wiring of a HST start equipment * = special electric equipment (please see literature “Electrical Equipment for Compressors”) (relay and not PTC) is used, the ** = GWFI 850°C and 2 sec

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss Compressors GmbH Mads Clausen Str. 7 D-24939 / compressors.danfoss.com AND DEHC.EI.200.D1.02/520N0207 Produced by Danfoss Compressors, DEHC6093, 09.2005