Hermetic Compressors R134a • 220V - 240V PL G TL-TLES-TLS-NL-NLE SC MAKING MODERN LIVING POSSIBLE G LBP/MBP Programme B B B 8224 8217 8221 Application Range

Total Page:16

File Type:pdf, Size:1020Kb

Hermetic Compressors R134a • 220V - 240V PL G TL-TLES-TLS-NL-NLE SC MAKING MODERN LIVING POSSIBLE G LBP/MBP Programme B B B 8224 8217 8221 Application Range LST - RSIR Hermetic Compressors R134a • 220V - 240V PL g TL-TLES-TLS-NL-NLE SC MAKING MODERN LIVING POSSIBLE g LBP/MBP Programme b b b 8224 8217 8221 Application Range a1 a1 a1 • Compressors with denominations ending with F are primarily designed for low evaporating temperatures (LBP Low Back Pressure) for use in refrigerators, freezers and similar applications in regions with stable supply voltage. d d d • Compressors with denominations ending with FT are designed for low evaporation temperatures (LBP Low Back Pressure) for use in refrigerators, freezers and similar applications operating in regions with unstable supply voltage. a1 Main winding a1 Start winding Main winding a1 Start winding Main winding Start winding • Compressors with denominations ending with FK are F-types designed for low evaporation temperatures N N N with LST starting characteristics (capillary tube). • Compressors with denominations ending with FX are F-types designed for low evaporation temperatures with HST starting characteristics (expansion valve). N L • Compressors with denominations ending with MF are primarily designed for medium evaporation temperatures N L N L C C C (MBP Medium Back Pressure) for use in commercial refrigerators, bottle coolers, ice machines and similar applications. Run Capacitor Holder Protection Screen for PTC Winding protector Winding protector Winding protector A run capacitor holder is available for the „Energy- Note: To fulfil the requirements optimized“ and „High Energy-optimized“ compressor of EN 60355-2-34 the protection HST - CSIR range. This optional part enables to fix the run screen 103N0476 must be applied PL TL-TLS-NL SC capacitor for 220V directly and earth-connected on to the PTC starting device. c c the compressor shell, concentrating all electrical acce- c ssories on the compressor. This will save space in the machine compartment. b 8222 Code numbers: run capacitor holder 117-0300 7363 b screw M4 x 8 PZD 2 117-0301 b a2 8435 8225 8219 a2 d a2 Model Designation d d c Compressor Optimization Compressor Application Start Generation 10 11 design level size range characteristics c c 10 11 10 11 12 13 14 12 13 12 13 PL 14 14 Start winding Blank Main winding Standard energy level F Blank ➞ Blank ➞ Winding protector R134a Main winding universal first generation Main winding Start winding Winding protector Start winding LBP/(MBP) Winding protector LST - RSCR HST - CSR TF, TL Nominal displacement (principal rule) S Semi-direct intake in cm3 PLE TLES-TLS-TLY-NLE-NLY GS a3 .2 ➞ FT e K = LST second g e R134a a2 e E Energy-optimized Exception: characteristics generation NF, NL LBP tropical TOP (optimized motor) For PL (capillary tube) c S C b R compressors the 8216 b capacity at rating MF .3 ➞ 8223-2 a1 Y High Energy- point is stated. R134 X = HST third 8543 SC a1 optimized MBP characteristics generation d Earthing d (yellow/green) (high optimization level) (expansion valve) d S tart (black) e etc. C ommon (brown) e b1 Main winding a1 R un (blue) N S Main winding b GS Start winding N S a1 b2 Winding Start winding protector C e Main winding 5 2 Start winding S R a2 N L C Examples N L 4 1 Bleeder resistance C 1 1 TL ES 5.2 F K .3 2 2 c N N L L a3 NL Y 9 F K Winding protector Winding protector M Thermostat Fan Danfoss Compressors SC 21 FT X Starting Device LST and HST Legend R134a • LBP/MBP Programme LST is used with capillary tube control and pressure equalizing. (Pressure equalizing a1: PTC starting device Danfoss Compressors GmbH a2: Starting relay 220-240 V • 50 Hz & 60 Hz may exceed 10 minutes). The PTC starting device requires 5 minutes cooling before a3: Starting devive Mads-Clausen-Strasse 7 each start. b: Cover D-24939 Flensburg Note: To fulfil the requirements of EN 60355-2-34 the protection screen 103N0476 b1/b2: Clamp/Gasket (part of comp.) Phone: +49 (0461) 4941-0 must be applied to the PTC starting device. c: Starting capacitor compressors.danfoss.com HST consisting of relay and starting capacitor, is used for expansion valve control or d: Cord relief e: Run capacitor for capillary tube control without pressure equalizing. g: Protection screen for PTC REFRIGERATION & AIR CONDITIONING DIVISION Quick reference DEHC.PB.400.I4.02/520N0320 Produced by Danfoss Compressors/DEHC 6093, 08.2006 Compressor Code numbers EN 12900 (CECOMAF) EN 12900 (CECOMAF) at ASHRAE subcooled at Displace- Recommended Voltage Electrical Equipment Compressor Dimensions TL PL Applications Comp- Comp- Capacity [W] LBP rating point -25°C / 55°C LBP rating point -23.3°C /54.4°C ment compressor cooling and LST (RSIR) LST (RSCR) Run capacitor 4 µF HST (CSIR) LST/HST Height Connectors ø16 LBP: Low Back Pressure pressor pressor Cooling COP COP Cooling COP without COP with at ambient frequen- PTC device w/o run PTC device with run 1) optional Starting Starting Cord Cover [mm] location/I.D. [mm] HBP: High Back Pressure with capacity without with Capacity run capacitor run capacitor temperature cies capacitor connector capacitor connector 2) compulsory relay capacitor relief Suc- Pro- Dis- Oil 70 MBP: Medium Back Pressure Level oil cooling Evaporating temperature [°C] RC RC spades spades spades spades tion cess charge cooler 70 Application ø16 Motor types -35 -30 -20 -15 -10 -5 0 [W] [W/W] [W/W] [W] [kcal/h] [W/W] [kcal/Wh] [W/W] [kcal/Wh] [cm3] 32°C 38°C 43°C 6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 4.8 mm 6.3 mm 6.3 mm A B C D E F 170 RSIR: Resistant Start Induction Run D C PL20F 101G0100 25 37 50 65 83 16 0.38 23 20 0.54 0.47 1.41 S S 1 103N0011 103N0018 103N1010 103N0491 PL20F 129 127 6.2 6.2 5.0 RSCR: Resistant Start Capacitor Run C 170 D E or or CSIR: Capacitor Start Induction Run PL35F 101G0202 45 60 79 101 125 32 0.64 44 38 0.85 0.73 2.00 S S 1 103N0011 103N0018 103N1010 103N0491 PL35F 134 132 6.2 6.2 5.0 D C PL50F (HST) 101G0222 56 74 95 120 148 40 0.69 56 48 0.92 0.79 2.50 F2 F2 1 117U6021 1175014 103N1010 103N0491 (HST) PL50F 137 135 6.2 6.2 5.0 E Starting devices B A TL2.5F 102G4200 47 65 86 110 137 32 0.59 45 39 0.79 0.68 2.61 S S 1 103N0011 103N0018 103N1010 103N2010 TL2.5F 163 159 6.2 6.2 5.0 LST: Low Starting Torque HST: High Starting Torque TL3F 102G4300 60 82 108 138 173 42 0.64 59 51 0.85 0.73 3.13 S S 1 103N0011 103N0018 117U6007 117U5014 103N1010 103N2010 TL3F 163 159 6.2 6.2 5.0 A B NL6.1MF 105G6660 141 189 245 312 390 245 ■ 1.31 ■ 6.13 F1 F1 F1 2/3 103N0011 103N0018 117U6015 117U5015 103N1010 103N2011 NL6.1MF 190 184 8.2 6.2 6.2 206 MBP Test conditions EN 12900 (CECOMAF) ■ ■ 8300 NL7.3MF 105G6772 179 236 304 385 480 304 1.34 7.27 F1 F1 F1 2/3 103N0011 103N0018 117U6016 117U5015 103N1010 103N2011 NL7.3MF 197 191 8.2 6.2 6.2 PL/TL/TLS/TLES/TLY/NL/NLE/NLY/SC 222 NL8.4MF 105G6879 213 277 353 445 553 353 ■ 1.36 ■ 8.35 F1 F1 F1 2/3 103N0011 103N0018 117U6016 117U5015 103N1010 103N2011 NL8.4MF 197 191 8.2 6.2 6.2 Application R134a ■ ■ 8301 Condensing temperature 55°C NL10MF 105G6885 105G6887 266 346 441 554 687 441 1.37 10.10 O/F1 O/F1 O/F1 2/3 103N0011 103N0018 117U6022 117U5018 103N1010 103N2011 NL10MF 203 197 8.2 6.2 6.2 6.2 130 Ambient temperature 32°C NL11MF 105G6151 292 380 485 609 756 485 ■ 1.35 ■ ■ MBP rating point -10°C / 55°C 11.15 F2 F2 F2 2 103N0011 103N0018 117U6022 117U5018 103N1010 103N2011 NL11MF 203 197 8.2 6.2 6.2 Suction gas temperature 32°C Liquid temperature 55°C GS26MFX ❍ 107B0700 754 989 1266 1591 1970 26.30 F2 F2 F2 1 Starting device (start. relay, start. & run capacitor), 600 mm cable length: 117-7055 107B9100/9001/9104 ❍ GS26MFX 259 247 12.9 6.5 8.2 157 220 V / 50 Hz GS34MFX ❍ 107B0701 958 1246 1596 2013 2505 33.80 F2 F2 F2 1 Starting device (start. relay, start. & run capacitor), 600 mm cable length: 117-7056 107B9100/9001/9104 ❍ GS34MFX 259 247 12.9 6.5 8.2 SC GS ø16 ø19 PL50F 101G0220 14 26 56 74 95 40 0.67 56 48 0.89 0.77 2.50 S S 1 103N0011 103N0018 103N1010 103N0491 PL50F 137 135 6.2 6.2 5.0 Application R134a TL4F 102G4400 31 44 81 107 137 61 0.75 83 72 0.98 0.84 3.86 S S 1 103N0011 103N0018 117U6009 117U5014 103N1010 103N2010 TL4F 163 159 6.2 6.2 5.0 Condensing temperature 45°C TLS / TLES / TLY Ambient temperature 32°C TL5F 102G4501 43 60 110 144 183 82 0.81 112 97 1.05 0.90 5.08 S S 1 103N0011 103N0018 117U6004 117U5014 103N1010 103N2010 TL5F 173 169 6.2 6.2 5.0 Suction gas temperature 20°C 127 TLS5F 102G4520 48 71 131 170 216 98 0.88 134 116 1.14 0.98 5.08 S S 1 103N0011 103N0018 117U6004 117U5014 103N1010 103N2010 TLS5F 173 169 6.2 6.2 5.0 ø16 70 Liquid temperature no subcooling Standard TLS6F 102G4620 58 77 139 183 235 104 0.87 142 122 1.13 0.97 5.70 S S 1 103N0011 103N0018 117U6004 117U5014 103N1010 103N2010 TLS6F 173 169 6.2 6.2 5.0 220 V / 50 Hz LBP TLS7F 102G4720 66 89 160 208 264 120 0.88 163 140 1.14 0.98 6.49 S S* 1 103N0011 103N0018 103N0016 103N0021 117-7117 117-7119 117U6000 117U5014 103N1010 103N2010 TLS7F 173 169 6.2 6.2 5.0 127 Conversion of capacity (R134a) 70 NL6F 105G6606 52 77 151 200 258 110 0.93 151 130 1.21 1.04 6.13 S S 1 103N0011 103N0018 117U6004 117U5015 103N1010 103N2010 NL6F 188 181 6.2 6.2 5.0 D 170 C If a stated capacity is required at 32°C liquid temperature, multiply the capacity NL7F 105G6706 71 99 182 238 303 136 0.93 186 160 1.20 1.03 7.27 S S 1 103N0011 103N0018 117U6000 117U5015 103N1010 103N2010 NL7F 190 183 6.2 6.2 5.0 with the following factor: E NL8F 105G6822 82 112 194 249 317 149 0.97 201 173 1.24 1.08 7.95 S S 1 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010 NL8F 197 191 6.2 6.2 5.0 C 170 D from 55°C to 32°C liquid: 1.231 NL9F 105G6802 105G6812 74 111 207 268 340 155 0.93 213 183 1.21 1.03 8.35 S S 1 103N0011 103N0018 117U6001 117U5015 103N1010 103N2010
Recommended publications
  • Danfoss Compressors A3 7363 Tropical Conditions M Thermostat Fan 220-240 V • 50 Hz & 60 Hz Legend Danfoss Compressors Gmbh • Mads-Clausen-Str
    LST - RSIR PL TL-TLES-TLS-NL-NLE SC MAKING modern Living PossiBLE g g b b 8224 b 8221 8217 a1 a1 a1 d d d a1 Start winding Main winding a1 Start winding Main winding Main winding a1 Start winding N N N N L N L C C N L C Winding protector Winding protector Winding protector Applications HST - CSIR PL TL-TLES-TLS-NL-NLE SC Our compressor range will perfectly fit various applications like: c c • Refrigerators and freezers c • Laboratory and medical equipment b • Clip-on and condensing units 8222 • Compressed air dryers b b a2 • Glass door merchandisers 8225 8219 a2 • Bakery refrigeration equipment a2 d • Low temperature display cabinets d d • Vending machines c 10 11 • Ice making machines c c 10 11 10 11 • Slush and frozen beverage makers 12 13 14 • Bottle coolers 12 13 12 13 14 14 Start winding Main winding Winding protector Main winding Start winding Main winding Start winding Winding protector Winding protector HST - CSR Protection Screen for PTC Abbreviations SC Note: Applications a3 To fulfil the requirements of EN 60355-2-34 the LBP: Low Back Pressure protection screen 103N0476 must be applied to HBP: High Back Pressure MBP: Medium Back Pressure a2 e the PTC starting device. Refrigeration Controls programme consists of: TOP c Motor types RSIR: Resistant Start Induction Run 8227 CSIR: Capacitor Start Induction Run CSR: Capacitor Start Run Starting devices d LST: Low Starting Torque Thermostatic expansion Hermetic filter drier Direct or servo operated Sight glass with b LST is used with capillary tube control and pressure valves with solid core solenoid valve moisture indicator equalizing.
    [Show full text]
  • Product Bulletin Design of Labels for BD Compressors
    Product Bulletin Design of Labels for BD Compressors Marking on Compressor & Electronic Unit Introduction All BD compressors are designed to Date of For the electronic unit, the code for meet specifications according to the manufacture date of manufacture is located on a EC type-approval certificate. label on the backside of the housing. In addition to that we have VDE and For the compressor see Product Bul- UL on most products. See Product Bul- letin (Technical Info) DEHC.EI.000.B . letin (Technical Info) DEHC.EI.100.C for further information. As we achieved Code numbers No BD code numbers will be affected VDE approval we were requested to by the changes. make some changes on the marking of electronic and compressor which Literature Our literature (data sheets) has been will be described in next section. updated with the new labelling. Valid from 2006 - updated 2009 Compressor label Nominal voltage has been removed and moved to the electronic unit. LBP/MBP marking has been removed. Electronic unit label VDE marking will not appear on the Voltage label due to the fact that the com- pressor can be applied with non VDE approved electronic units. BD type label Electronic unit label The label contains the nominal supply voltage. Located between + and – ter- minal. The AC/DC electronic contains in addition the applied nominal AC voltage. UL label Voltage has been re-established on UL label the UL label and can also be found on RoHS marking the electronic unit. Danfoss Compressors GmbH • Mads-Clausen-Str. 7 • D-24939 Flensburg / Germany • Tel: +49 (0461) 4941-0 • Fax: +49 (0461) 44715 • compressors.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material.
    [Show full text]
  • Total Environmental Impact of a Small Hermetic Compressor P
    Purdue University Purdue e-Pubs International Refrigeration and Air Conditioning School of Mechanical Engineering Conference 1994 Total Environmental Impact of a Small Hermetic Compressor P. E. Hansen Danfoss Compressors GmbH V. Gustafsson Danfoss Compressors GmbH I. Drabaek de-Teknik A. Schmidt de-Teknik P. B. Pedersen de-Teknik Follow this and additional works at: http://docs.lib.purdue.edu/iracc Hansen, P. E.; Gustafsson, V.; Drabaek, I.; Schmidt, A.; and Pedersen, P. B., "Total Environmental Impact of a Small Hermetic Compressor" (1994). International Refrigeration and Air Conditioning Conference. Paper 245. http://docs.lib.purdue.edu/iracc/245 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html Total Environmental Impact of a Small Hermetic Compressor By Poul Erik Hansen, Vibeke Gustafsson Danfoss Compressors GmbH. P.O. Box 1443. D-24939 Flensburg. Germany. Tlf int. + 49464941·109, Fax Int. + 494614941-629 lver Drabek, Anders Schmidt, Preben Buhl Pedersen dk-Teknik, Gladsaxe Moellevej 15, OK 2860 S"borg, Denmark ABSTRACT The relative energy consumption caused by the introduction of the alternative refrigerants has been seen as very important while replacing the CFC's. In the framework of the TEWI concept the influence of alternative refrigerants on the global warming is calculated, taking into account the direct and indirect effect. This paper extends these analyses as it includes the influence of a hermetic compressor in its total lifetime from the production of raw materials to the disposal of the compressor.
    [Show full text]
  • Danfoss Compressors
    MAKing modern Living PossiBLE R600a Danfoss Compressors 220-240 V • 50 Hz & 60 Hz REFRIGERATION & AIR CONDITIONING DIVISION Quick reference Compressor Code number EN 12900 (CECOMAF) EN 12900 (CECOMAF) at ASHRAE subcooled at Capacity [W] LBP rating point -25°C / 55°C LBP rating point -23.3°C / 5 Cooling COP COP Cooling COP Capacity without with Capacity without RC Level Evaporating temperature [°C] RC RC Application -35 -30 -20 -15 -10 -5 0 5 [W] [W/W] [W/W] [W] [kcal/h] [W/W] [kcal/Wh] 1. PLE35K 101H0360 38 52 68 87 109 27 0.68 38 33 TLES4KK.3 102H4438 19 29 57 75 96 42 0.90 57 49 1.18 1.02 TLES4.8KK.3 102H4538 28 40 73 94 119 55 1.00 74 65 1.30 1.12 TLES5.7KK.3 102H4638 36 50 89 114 144 68 1.02 91 79 1.32 1.14 3. TLES6.5KK.3 102H4738 45 61 105 134 168 81 1.02 108 94 1.31 1.13 TLES7.5KK.3 102H4838 53 71 122 155 194 94 1.02 1.07 126 108 1.32 1.14 TLES8.7KK.3 102H4938 62 83 143 181 228 110 1.03 1.08 147 126 1.33 1.14 TLES10KK.3 102H4038 73 97 162 205 255 126 0.98 1.06 168 145 1.26 1.08 NLE8.8KK.4 105H6800 63 84 141 179 223 110 1.18 1.22 147 127 1.51 1.30 Energy-optimized NLE10KK.4 105H6867 74 98 164 207 257 128 1.19 1.23 170 151 1.51 1.30 4.
    [Show full text]
  • Survey of Starting Capacitors
    Technical Info Survey of Starting Capacitors The following table shows code numbers and technical information about starting capacitors: Code no. Capacity Voltage Stamping IEC Bleeder Mount Comp. Approvals Supplier [µF] [V] Resistor L / D [mm] 220V AB 1.7% ED BHC / NGM 117U5012 125 220 no A SC VDE / UL 300V AB 0.1% ED 121/39 95/39 D A 220V AB 1.7% ED BHC / NGM 117U5014 60 220 no A PL, TL VDE / UL 300V AB 0.1% ED 95/39 L 220V AB 1.7% ED BHC / NGM B 117U5015 80 220 no A FR, NL VDE 300V AB 0.1% ED 95/39 220V AB 1.7% ED BHC / NGM 117U5017 80 220 no A SC VDE / UL 300V AB 0.1% ED 95/39 8621 220V AB 1.7% ED BHC / NGM 117U5018 125 220 no A NF, NL VDE / UL 300V AB 0.1% ED 121/39 95/39 220V AB 1.7% ED BHC 117U5019 80 220 no A SC VDE / UL 300V AB 0.1% ED 95/39 A clamp (snap-on) 125V AB 1.7% ED BHC / NGM B holder (bracket) 117U5022 320 115 no A NF, TFS UL 165V AB 0.1% ED 80/39 D diameter 125V AB 1.7% ED TL, TLS, BHC / NGM 117U5023 240 115 no A UL L lenght 165V AB 0.1% ED SC 80/39 125V AB 1.7% ED FR, NF, BHC / NGM 117U5025 280 115 no A UL 165V AB 0.1% ED TF, TFS 80/39 125V AB 1.7% ED BHC / NGM 117U5028 410 115 no A NF UL 165V AB 0.1% ED 95/39 Please get in touch with your Danfoss 125V AB 1.7% ED BHC contact if any further information is 117U5040 320 115 no B FF UL 165V AB 0.1% ED 95/39 needed.
    [Show full text]
  • Analysis of R134a Cabinets from the First Series Production in 1990 A
    View metadata, citation and similar papers at core.ac.uk brought to you by CORE provided by Purdue E-Pubs Purdue University Purdue e-Pubs International Refrigeration and Air Conditioning School of Mechanical Engineering Conference 1996 Analysis of R134a Cabinets from the First Series Production in 1990 A. Riemer Danfoss Compressors GmbH P. E. Hansen Danfoss Compressors GmbH Follow this and additional works at: http://docs.lib.purdue.edu/iracc Riemer, A. and Hansen, P. E., "Analysis of R134a Cabinets from the First Series Production in 1990" (1996). International Refrigeration and Air Conditioning Conference. Paper 372. http://docs.lib.purdue.edu/iracc/372 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html ANALYSIS OF R134a CABINETS FROM THE FIRST SERIES PRODUCTION IN 1990. Alice Riemer, Paul Erik Hansen, Danfoss Compressors GmbH. Mads Clausen Strasse 7, D-24939 Flensburg, Germany. ABSTRACT Series production of R134a compressors started in 1990. 200 compressors, from the very first series, were built into cabinets placed in an apartment house in Denmark. Cabinets with R12 compressors were placed in the same apartment house as well. The cabinets have two separate cooling systems; one for a cold cabinet and one for a freezer. 10 running cabinets were called back for analysis; 7 cabinets with R134a compressors and 3 cabinets with R12 compressors. Analysis of the cabinets comprises both the refrigeration systems and the compressor from each system.
    [Show full text]
  • Time Delay Relay for SC-Twin SD 117N0001, 220-240V, 50 & 60Hz
    Technical Info Time Delay Relay for SC-Twin SD 117N0001, 220-240V, 50 & 60Hz Introduction Technical data Code number 117N0001 Voltage 220 - 240 V Min. supply voltage 187 V Max. supply voltage 255 V Mains frequency 50 to 60 Hz Max. operating current 7 (7) A Max. starting current 25 A for 4 seconds Temperature range, operation -10 to 55°C Temperature range, storage -40 to 70°C The time delay relay type SD is Time delay at 25°C, 220 V 10 to 25 seconds designed for staggered start of Mounting orientation to suit installation two compressors in the Twin- Life time 500.000 cycles, 50.000 hours version as the one-phase mains Enclosure IP 20 2 cannot normally be loaded with Connection cable / spade connectors 3 x 0,75 mm / 6.3 mm the total starting current of both compressors. When the time delay relay is used, ø 3.8 first one compressor is started, and about 10 seconds later the second compressor is started. This ensures the best possible characteristics SD 117N0001 35 73 and the least load on the mains. 220 / 240 V 50 / 60 Hz 7(7) A The time delay relay has the t 10 - 25 sec. 550 Black Brown 14 following specification: L t Blue N 12 60 108 28 1903 REFRIGERATION AND AIR CONDITIONING Wiring diagrams CSIR Starting relay Starting capacitor N Start winding 10 11 10 11 Main winding 12 13 12 13 Blue 14 Winding protector 14 L Black Brown Thermostat Time delay relay 1969 Winding protector Starting capacitor CSR Main winding Start winding Run capacitor Starting relay Bleeder resistance N 5 2 5 2 4 1 4 1 Black L Brown Blue Time delay relay 1970 Thermostat Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material.
    [Show full text]
  • Modified Cover Material 220-240V/50Hz Compressors
    Technical Info Modified Cover Material 220 - 240V / 50Hz Compressors In the latest standard “Safety of Therefore, Danfoss will change In case of the standard Ultramid household and similar electrical the material of the cover in con- cover (code no. 103N2010) for TL, appliances, IEC60335-1, Edition 4” nection with our TL, NL, and FR NL, and FR it is permissible that an the flammability safety demands compressors for 220-240V/50Hz inside electrical connection touch- have been changed. operation from Capron 8202 to es the cover. However, there has This new standard becomes Ultramid B3S and in connection to be a certain free space outside effective in EU (EN 60335-1) from with our PL, TF, NF, FF, and SC the cover (ø 20x50 mm to electrical October 2005 for light commercial compressors for 220-240V/50Hz connections). If this is not the case, appliances and from October operation to Noryl SE1. the “disturbing” external part has 2006 for household appliances. The change of material will take to be of non-flammable material or Other countries can have different place by the end of September it has to be able to pass the needle schedules. 2005 at the latest. flame test. Danfoss will change the cover material according to the table to 220 - 240V / 50Hz Material comply with this new standard. Compressor type Cover code no. Today New The cover code nos. will not be PL 103N0491 Capron 8202 Noryl SE1*** changed. Standard = 103N2010 Capron 8202 Ultramid B3S** TL, NL, FR Our existing Capron 8202 covers Special = 103N2011 Noryl SE1*** would normally (e .g.
    [Show full text]
  • Final Webpage Conference1
    2004 CONFERENCES About the Conferences The conferences are organized by faculty from the Ray W. Herrick Laboratories, Purdue University, in cooperation with many sponsoring and cooperating organizations from around the world. They have taken place every two years for over 30 years. Their focus is on the results of recent research into compressors and other technologies associated with air conditioning and refrigeration. Over 500 people from 32 different countries attended the conferences held in July, 2002 with a total of 220 papers published in the CD-ROM and hard copy proceedings. The conferences’ technical sessions run simultaneously enabling attendees to attend sessions of interest from either conference. The Purdue conferences provide an opportunity for practitioners and researchers in industry, government, consulting offices, laboratories, and universities to reach a large audience, to exchange current engineering information, problems, and solutions on the important issues of compressor technology, new refrigerants, and refrigeration technology and efficiency. In addition to paper presentations, invited speakers will make presentations at plenary sessions on selected topics of interest. Cost for full registration is $650. This price includes attendance at any session for either conference, a CD-ROM containing the proceedings for both conferences, 20 copies of papers as well as the Monday evening reception, Tuesday night steak barbeque and Wednesday evening’s banquet. All conference hotels are located near the campus or just across the river in Lafayette. There are many new and various restaurants, bars and shops available for attendee’s entertainment in both the Purdue Village, Wabash Landing and downtown Lafayette. Most establishments are within walking distance of all hotels and/or shuttle and trolley service will be available.
    [Show full text]
  • Annual Report Danfoss Ready for the Future
    Annual Report Danfoss ready for the future www.danfoss.com 2013www.danfoss.com Danfoss at a glance Danfoss is a world-leading supplier of technologies that meet the growing need for food supply, modern infrastructure, efficient energy utilization and climate- friendly solutions. The Group is divided into two business segments: Danfoss Climate & Energy and Danfoss Power Solutions. Danfoss Climate & Energy's key expertise lies in food refrigeration, air conditioning systems, controls for electric motors, heating systems for buildings, and components for renewable energy, including solar and wind energy. Danfoss Power Solutions' key expertise is in hydraulic systems and compo- nents for powering mobile machinery used in agriculture, construction, materials handling, and specialty equipment. Danfoss is a privately-owned company that has grown and improved its skills and expertise in energy-efficient solutions over the past 80 years. Danfoss sells its products in more than 100 countries and employs some 22,500 people worldwide. Danfoss… Approximate headcount: 22,500 Products sold in over 100 countries worldwide Top five markets: USA, Germany, China, Russia and Italy Has 59 factories in 18 countries and 58 sales companies in 46 countries Headquartered in Nordborg, Denmark Find us here: Facebook: www.facebook.com/Danfoss Twitter: www.twitter.com/Danfoss Google+: http://plus.google.com/+danfoss YouTube: www.youtube.com/DanfossGroup LinkedIn (Company Page): www.linkedin.com/company/Danfoss 2 Annual Report 2013 I The Danfoss Group CONTENT 4 2013 HIGHLIGHTS 6 LETTER FROM THE EXECUTIVE COMMITTEE 9 FINANCIAL HIGHLIGHTS 10 CORE & CLEAR STATUS 14 INNOVATION 2013 18 FINANCIAL REVIEW 30 FINANCIAL REVIEW, SEGMENT 34 OUTLOOK FOR 2014 42 CORPORATE GOVERNANCE 50 SUSTAINABILITY 52 RISK MANAGEMENT & COMPLIANCE 56 GROUP COMPANIES 60 MANAGEMENT REPORT FOR DANFOSS A/S 61 MANAGEMENT STATEMENT 62 INDEPENDENT AUDITOR'S REPORT 63 ACCOUNTS AND NOTES Annual Report 2013 I The Danfoss Group 3 2013 highlights FINANCIAL PERFORMANCE Danfoss maintained a high level of sales in 2013.
    [Show full text]
  • Danfoss Compressors
    LST - RSCR LST - RSIR Hermetic Compressors R600a • 220V - 240V PL g TL-NL e TL-NL g g for Refrigerators and Freezers b b 8224 8217 Application Range Yellow Warning Label b 8223 All compressors for R600a have denominations ending with K after the number for displace- a1 a1 ment or capacity. a1 d d They are designed for low operating temperatures - LBP (Low Back Pressure) for use in refri- d gerators, freezers and similar applications. Main winding a1 Start winding e Main winding a1 Start winding Compressors with endings K and KK are designed for regions with stable supply voltage. N a1 Main winding N S N Endings KTK are designed for less stable supply voltage and tropical conditions. Start winding Some of the smaller compressors and the variable speed compressors are also released for medium operating temperatures - MBP (Medium Back Pressure). N L L N L N 2 C C C Danfoss Compressors R600a 8122- Starting device LST and HST Winding protector Winding protector Winding protector • R600a is flammable in concentrations of air between approximatey 1.5% and 8.5% by volume Variable Speed Drive Protection Screen for PTC (LEL lower explosion limit and UEL upper explosion limit). • An ignition source at a temperature higher than 460°C is needed for a combustion to occur. TLV NLV Note: To fulfil the requirements of • Isobutane is significantly different from R12 and R134a. This means that compressors for R600a cannot be used with R12 or R134a. Screw 3.5x12 mm Screw 3.5x12 mm EN 60355-2-34 the protection screen Mounting Compressor Mounting Compressor recesses recesses 103N0476 must be applied to the PTC • No high potential test nor start tests must be carried out while the compressor is under vacuum.
    [Show full text]
  • Development of Small Hermetic Compressors for R600a P
    Purdue University Purdue e-Pubs International Compressor Engineering Conference School of Mechanical Engineering 1994 Development of Small Hermetic Compressors for R600a P. E. Hansen Danfoss Compressors GmbH L. Snitkjaer Danfoss Compressors GmbH M. Skovgaard Danfoss Compressors GmbH A. Riemer Danfoss Compressors GmbH Follow this and additional works at: https://docs.lib.purdue.edu/icec Hansen, P. E.; Snitkjaer, L.; Skovgaard, M.; and Riemer, A., "Development of Small Hermetic Compressors for R600a" (1994). International Compressor Engineering Conference. Paper 1045. https://docs.lib.purdue.edu/icec/1045 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html "DEVELOPMENT OF SMALL HERME11C COMPRESSORS FOR R600a" By Poul Erik Hansen, Lars Snitkjmr, Michael Skovgaard and Alice Riemer Danfoss Compressors GmbH. P.O. Box 1443. D-24939 Flensburg. Germany. Phone + 49464941-109, Fax + 494614941-629 ABSTRACT Recently the possibility of using R600a has gained popularity among producers of household refrigerators in Europe, especially in Germany. This paper dea's With the development of small hermetic compressors for this refrigerant. Part one is describing the themodynamical properties that are influencing the compressor performance. Measurements and compressor simulations
    [Show full text]