Product Catalogue

COMPONENTS MEASUREMENT SYSTEMS

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 1 04/02/2016 11:53 Nuclear Measurement Specialists

Nuvia provides standard and tailored From modelling to implementation, measurement solutions to nuclear Nuvia uses exclusive know-how owners, operators and stakeholders and state-of-the art technologies in for all stages of the facilities’ life cycle. its monitoring systems dedicated Nuvia can supply both components to six major fields of application: (detectors, analysers and software) waste management, homeland or complete measurement systems security, laboratories, health physics, which can incorporate carrier continuous process monitoring and equipment, conveyor equipment, GPS environmental monitoring. control, signal processing units.

VERTICAL INTEGRATION, A RANGE Automation and control-command: Assembly of pneumatic components and control-command, system design and state of OF STANDARD AND TAILOR MADE the art documentation processing, 3D design, electronic projection, PRODUCTS PLC programming, development of control-command specific software, visualisation and data collection. Modelling: assistance with identifying requirements, numerical Software developments with a dedicated team: strong experience in modelling, any type of photon and performance simulation acquisition systems and analysis of nuclear measurements, expertise calculations. across many areas of development (such as embedded applications, Design: preliminary studies, detailed or implementation studies, databases, protocols for data acquisition). choice of equipment including sensors, mechanics, automation, Qualification: specifying procedures, verification and qualification control command, sizing, sensor type. of performance from QCT modelling of the system and Mechanics: custom manufacturing in our workshops of conveyors measurements with radioactive sources. and structural equipment; treatment of material, machined Commissioning: specifying appropriate factory and on-site test and welded parts, metal structures, lead or steel shields and procedures, unit testing and factory calibration with radioactive collimators, and low background shielding made of modular sources, undertaking testing following factory or on-site assembly. concrete bricks.

2

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 2 04/02/2016 11:53 Contents

COMPONENTS Detectors and Probes (NuDET) NuDET AB...... p.05 NuHLS PORTAL D...... p.25 NuDET NAI...... p.05 NuHLS PORTAL P...... p.25 NuDET PLASTIC...... p.05 NuHLS PORTAL U...... p.25 NuDET NEUTRON...... p.05 NuHLS PORTAL M...... p.26 NuDET EGM...... p.06 NuDET EPL...... p.06 Protection and Decommissioning (NuHP) ...... NuDET ENA...... p.06 NuHP CoMo-170 p.29 ...... NuDET ENA UW...... p.07 NuHP CoMo-170G / CoMo-300G p.29 NuHP CoMo DETECTORS...... p.29 Software Solutions (NuSOFT) NuHP CoMo-170 MF...... p.30 NuSOFT GAMWIN...... p.08 NuHP HFC...... p.30 NuSOFT AIRIS/SIRIS...... p.08 NuHP ECMo...... p.30 NuSOFT MAPCONVERT...... p.08 NuHP SCINTO...... p.31 NuSOFT AGRS CALIB...... p.09 NuHP WIMP...... p.31 NuSOFT DATAVIEW...... p.09 NuHP WIMP 60X...... p.31 NuSOFT PRAGA...... p.09 NuHP TOOLMOON...... p.32 NuSOFT RAMON...... p.10 NuHP DRAMON...... p.32 NuSOFT DORMIS...... p.10 NuHP RCB...... p.32 NuSOFT WASTIS...... p.10 NuHP LARS G...... p.33 NuSOFT MBA...... p.10 NuHP LARS W...... p.33 NuSOFT INSPECTIONS...... p.11 NuHP LAUMO C...... p.34 NuSOFT METROLOGY...... p.11 NuHP LAUMO D...... p.34 NuSOFT CLARA...... p.11 NuHP LAUMO R...... p.34 NuSOFT RADIS...... p.11 Laboratories (NuLAB) Digital Analyzers (NuNA) NuLAB FC-25...... p.37 NuNA SCA...... p.12 NuLAB FNF...... p.37 NuNA SCA T...... p.12 NuLAB LBOX...... p.37 NuNA MCB...... p.12 NuLAB LDIG...... p.38 NuNA MCB T...... p.13 NuLAB ASC...... p.38 NuNA PMP...... p.13 NuLAB MORA VAN...... p.38 NuLAB MORA ISO...... p.39 MEASUREMENT SYSTEMS Radiation Monitoring Systems (NuRMS) NuRMS GASEM...... p.41 Waste Management (NuWM) NuRMS PRICOM...... p.41 NuWM GAMS 1...... p.17 NuRMS N16...... p.41 NuWM GAMS 2...... p.17 NuRMS MECOP...... p.42 NuWM GAMS 3...... p.17 NuRMS EGS...... p.42 NuWM GAMS 4...... p.17 NuRMS AREA MU...... p.42 NuWM MUM...... p.18 NuRMS AREA SU...... p.43 NuWM GEM...... p.18 NuRMS AREA TU...... p.43 NuWM HIRAM...... p.18 NuRMS ALMO...... p.43 NuWM RCS...... p.19 NuWM MASTAB...... p.19 Environmental Monitoring (NuEM) NuEM RAMS...... p.45 Homeland Security and Civil Defense (NuHLS) NuEM RAMS UW...... p.45 NuHLS AIRIS...... p.21 NuEM RAMSAT...... p.45 NuHLS IRIS...... p.21 NuEM GROUNDHOG...... p.46 NuHLS SIRIS...... p.21 NuEM GROUNDHOG V...... p.46 NuHLS IMPAC...... p.22 NuEM GROUNDHOG P...... p.46 NuHLS FIXIS...... p.22 NuEM DRONES G...... p.47 NuHLS CoMo-170 ZS...... p.22 NuHLS PDOSE...... p.23 NuHLS PGIS...... p.23 NuHLS PGIS P...... p.23 NuHLS RADREFLEX...... p.24 NuHLS FAMO...... p.24 NuHLS PORTAL V...... p.24 3

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 3 04/02/2016 11:53 COMPONENTS

Nuvia offers a full catalogue of very reliable components which can be tailored to your needs, such as detectors, digital analysers and software (data logger & data processing). Our components are designed and manufactured in our workshops and are the result of our R&D programmes for integration into our measurement systems.

4

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 4 04/02/2016 11:53 Components Detectors and Probes (NuDET)

NuDET NuDET NuDET NuDET AB NAI PLASTIC NEUTRON

Alpha and beta NaI(Tl) scintillators Plastic scintillator Neutron detectors scintillators and probes detectors Highly efficient and High efficient and Quality NaI(Tl) Premium plastic gamma insensitive reliable ZnS(Ag) alpha, scintillation detectors scintillation detectors and neutron detectors. beta and alpha/beta and probes in standard assemblies designed for Newly developed scintillation detector and custom sizes for wide variety of applications. LiF6/ZnS based and assemblies gamma spectrometry Thin layers/foils are detectors are available for wide variety of and counting devices. suitable for detection of in both standard applications - surface Scintillators are protons, electrons and and customised contamination, air contained in low- beta particles. Larger dimensions and filters, smears and mass, light-tight volume detectors are used available with wipe tests. Available aluminium housings. for measuring gamma optional HDPE in a variety of shapes Probes are integrally radiation. Detectors moderator. Detectors and dimensions, mounted scintillation can be fixed to the light are supplied with completed with PMT assemblies containing guide, completed with standard 14-pin (1 1/8” and 2”) and a NaI(Tl) crystal a photomultiplier or socket or with voltage MHV connector. optically coupled to provided as basic detectors dividers and MHV/ Manufacture of alpha a PMT, integrated with no additional BNC connectors. scintillation chamber voltage divider, components. Available BF3 detector: 50x900mm (Lucas cell) for Radon magnetic shielding in both standard and Moderator thickness: 70 mm measurement with and user selectable customised dimensions. LiF/ZnS detector: 50x100x500 mm a glass window and connector or cable 2” PMT with standard PMT: 2” with standard 14-pin gas-tight valves, inner interface. Detectors: 14-pin socket or well type Mod thickness: 30 mm HDPE surface covered with available in various 1 1/8” PMT, complete with ZnS(Ag) scintillator. sizes, including well voltage divider and MHV

Shielding foil: < 1 mg.cm-2 types. connector. Alpha luminofor: ZnS(Ag) Resolution for 2x2”: <7% Max. length of blocks: Beta luminofor: foil type SPF 32 Resolution for 3x3”: < 7.5% 2000 mm Wavelength max.: 425 - 465 nm PMT: with standard 14-pin socket Max. weight: 60kg Max. illumination: 1000 lx Connectors: MHV or BNC Standard thickness: 50 and 100mm Max. cylinder dimension: 250x250mm

5

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 5 04/02/2016 11:53 Components Detectors and Probes (NuDET)

NuDET NuDET NuDET EGM EPL ENA

Intelligent GM gamma Intelligent plastic gamma Intelligent NaI(Tl) gamma probe series probe series probe series Gamma probe models Intelligent plastic detector NaI(Tl) Intelligent Probes are based on various gamma module is the main are designed for gamma combinations of GM tubes part of NUVIA’s Modular spectroscopy monitoring. and serve a wide variety Screening Systems but can These probes can be used of applications focused on also be used independently independently or as part of radiation monitoring and for dose rate monitoring or as different systems for a wide measurement in outdoor a part of various measuring variety of applications. They and indoor environments. devices. Available in different have been designed for Combination of GM tubes size/shape and volumes. sensitive measurement of provides the detection range Detector: high-volume plastic dose rate and of ambient equivalent dose scintillation detectors analysis. Probes are available rate spanning 9 decades. Connectivity: RS-485 with NUVIA or with 2x2” and 3x3” NaI(Tl) ModBUS protocol. Rugged housing enables the detectors with integrated probes to be used in harsh MCB analyser. An optional conditions. weather sensor is also Detection range: from 10 nSv/h up to available. 10 Sv/h Operation temp.: -25˚C to +55˚C Temp. range: -10°C to +50°C Interfaces: USB + RS232 + RS485 or USB Optionally thermal regulation + Ethernet LAN (E suffix) Interface: USB, LAN (Ethernet) Protection level: IP-67

6

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 6 04/02/2016 11:53 Detectors and Probes (NuDET)

NuDET ENA UW

Intelligent NaI(Tl) gamma underwater probes Water probes are available with 2” or 3” NaI(Tl) detectors with an integrated MCB analyser. System is designed for gamma spectroscopy monitoring in water. Connectivity is provided by Ethernet interface, USB or RS-485. Detector stabilisation is based on gain shift, controlled by the position of the 1460 keV peak from K-40. Ethernet or GPRS connection (from cabinet) to the monitoring center. E-Range: 40 keV up to 3 MeV Temp. range: -10°C to +50°C Max. water deep: 50m Probe IP 68, Cabinet IP 65

7

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 7 04/02/2016 11:53 Components Software Solutions (NuSOFT)

NuSOFT NuSOFT NuSOFT GAMWIN AIRIS/SIRIS MAPCONVERT

Gamma and alpha Data acquisition software Survey preparation and spectroscopy analysis for airborne and mobile post-mission visualisation software package systems software GAMWIN is a software AIRIS/SIRIS is a Windows The MAPCONVERT package designed for based, real time data software allows the user to comprehensive spectral acquisition and survey prepare a survey, including analysis and evaluation navigation software package calibrating the survey map for data obtained from for PEI mobile and airborne images, defining the survey semiconductor and systems. AIRIS/SIRIS supports area, creating the survey scintillation detectors which multiple instruments data grid, survey and tie-lines, has been developed for logging, including AGRS allocating the survey Windows. spectrometers, GPS, radar, measuring points, etc. During The system includes features altimeter, barometric pressure the post-mission processing for nuclide identification and sensors, temperature sensors, the MAPCONVERT software quantification, peak searching video camera and other application can be used for and area determination, peak installed instruments. AIRIS/ quick and easy visualisation fitting (including the fitting SIRIS provides real time data of the survey path with of multiplets), background acquisition information, graphical visualisation of subtraction and more. gamma-ray spectrum observed peak height in

OS: Windows representation, as well as selected channel. operator and pilot navigation. OS: Windows The Pilot Guidance Unit (PGU) screen can be installed and will be supported by AIRIS/ SIRIS software. AIRIS/SIRIS will notify the operator/pilot if the acquired data exceeds preset limits or in the event of equipment malfunction.

OS: Windows

8

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 8 04/02/2016 11:53 Software Solutions (NuSOFT)

NuSOFT NuSOFT NuSOFT AGRS CALIB DATAVIEW PRAGA

Calibration and setting Data quality control Gamma spectroscopy data software for AGRS based visualisation and GIS export processing software instruments software tool PRAGA is a radiometric The AGRS Calib software is DATAVIEW is intended processing tool that makes designed for calibration and for working with survey the most of the information experimental verification of data collected using PEI stored in the gamma-ray portable, mobile and airborne instrumentation. The spectrum to evaluate the instruments based on AGRS DATAVIEW application activity of natural and technology. This SW tool provides easy and quick man-made radioactive is used for initial energy data quality control, ground sources. The PRAGA calibration of a system and performance, visualisation, offers classic MSN and for re-calibration in case of data analysis, and data export advanced NASVD processing detector replacement for for processing, gridding and techniques that allows the maintenance. AGRS Calib presentation. The data can user to extract maximum allows measurement of be converted and exported spectroscopic information the resolution of detectors, to different GIS formats: from the data. PRAGA control of the tuning process ASCII, table text, Geosoft, is designed for airborne as well as checking the KMZ, ANSI N42.42 and other projects; PRAGA has been stability and linearity of the formats. modified to make mobile spectra. The AGRS Calib DATAVIEW also offers and ground surveys more offers capability to set the spectroscopic data simple. PRAGA includes a general parameters such as processing such as peak radon removal technique, HV, detector volume, range of resolution and non- elimination of vehicle energy, sensitivity and many linearity calculation, point background, correction for others. source activity estimation, meterological conditions and OS: Windows verification of calibration on others. pads and other. OS: Windows OS: Windows

9

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 9 04/02/2016 11:53 Components Software Solutions (NuSOFT)

NuSOFT NuSOFT NuSOFT RAMON DORMIS WASTIS NuSOFT Monitoring and data Software for radiation control visualisation software inside buildings MBA

RAMON is an efficient tool DORMIS is an efficient tool and fuel for gathering, evaluating for radiation control inside management software and publishing radiation buildings (RMS), personal WASTIS is an excellent monitoring data transferred dosimetry and access control solution for all waste via GSM (GPRS), satellite (dosimetry). Data from producers, waste processors and/or ethernet. The system all network appliances is and for temporary or long is particularly well suited transferred to one database. term waste repositories. It to data from monitoring The software is primarily simplifies and optimises all station networks and mobile intended for radiation data activities regarding waste and portable radiation management; however can recording, moving, processing, measurement instruments be modified to operate with tracking and reporting. (data from radiation, air various types of sensors – and MBA is intended for recording pollution or other physical radiation monitoring devices and nuclear quantities monitoring (radiometry and dosimetry material evidence, including networks). Data is visualised data acquisition, processing, fuel receipt, transportation using a web application. evaluation and visualization). and disposal. The information The system is designed for The systems comprises two system is able to generate a radiation environmental main modules - Personal documents for state nuclear monitoring centre (SCADA). Dosimetry and RMS. regulators, International Atomic Energy Agency (IAEA) and EUROATOM

10

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 10 04/02/2016 11:53 Software Solutions (NuSOFT)

NuSOFT NuSOFT INSPECTION CLARA NuSOFT NuSOFT METROLOGY RADIS

Software for inspection, Laboratory information planning and management of management system for metrology laboratories chemical and radiometric laboratories INSPECTION is a very powerful application based CLARA information system for on the implementation of the chemical laboratories covering legislative requirements for an comprehensive sample NPP operator. This software information and results of package manages the list of techniques undertaken in the mandatory checks for NPP laboratories. equipment that are subject RADIS information system is to approval by the Nuclear LIMS type system suitable Authority. for radiometric laboratories METROLOGY is a database focused on gamma system specifically designed spectroscopy. for metrology laboratories. The software’s functionality includes recording customer information, device informa- tion, copies of documenta- tion produced, monitoring of orders and more. The system is also designed to be used at a client’s location.

11

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 11 04/02/2016 11:53 Components Digital Analyser (NuNA)

NuNA NuNA NuNA SCA SCA T MCB

Digital four-channel counter Desktop digital Digital multichannel four-channel counter analyser Powerful digital four-channel counter designed for signal Powerful digital four-channel The NuNA MCB digital processing from plastic counter dedicated to the multichannel analyser scintillation detectors. signal processing primarily in a compact housing Detectors are connected from plastic scintillation serves as an MCA base for directly into the counter detectors. Detectors are processing signals coming using PMT socket on the connected through the single from detectors equipped rear panel. The front panel is BNC or MHV connector on with a 14-pin, 10-stage equipped with an Ethernet the rear panel. The front panel photomultiplier tube. Signal interface for connecting to is equipped with an Ethernet processing enables the local network and the USB interface for connecting to display of energy spectra interface for connecting local network and a USB from photon radiation directly to the PC. GAMWIN interface for connecting detected by the most Software provides control and directly to a PC. Provided with common types of scintillation display interface. software GAMWIN to control detectors such as NaI(Tl), and display. LaBr3 (Ce), plastic materials PMT socket: 14 pin PMT (10 stages) USB-B connector, Ethernet (RJ45) Micro SD USB-B connector and others. MCB comprises slot (local data storage) Ethernet (RJ45) a 14-Pin PMT socket, Power Supply: USB or 9V - 30V / 2W DC Micro SD slot (local data storage) preamplifier, high voltage Power Supply: USB or 9V..30V / 2W DC supply and control unit. MCB can be connected to a local network using the Ethernet interface or to a computer using the USB interface. GAMWIN Software provides control and display interface.

PMT socket: 14 pin PMT (10 stages) USB-B connector, Ethernet (RJ45) Micro SD slot (local data storage) Power Supply: 9V to 30V / 3W DC Conversion Gain: up to 2048 channels

12

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 12 04/02/2016 11:53 Digital Analyser (NuNA)

NuNA NuNA MCB T PMP

Desktop digital Scintillation PMT divider multichannel analyzer with preamplifier The NuNA MCBT digital The NuNA PMT base with multichannel analyser is a active PMT divider and table version of MCB with an preamplifier serves as a link added variable gain amplifier, between standard 14-pin, preamp power supply, high 10-stage photomultiplier voltage supply and status tubes and signal processing display. MCBT can be electronic devices (MCA, connected to a local network counters). The PMT base is using the Ethernet interface equipped with an industry or to a computer using the standard high voltage USB interface. The rear panel connector SHV, signal output is equipped with a standard BNC and NIM compatible SHV high voltage connector, power supply D-SUB. BNC signal input and NIM PMTHV version incorporates compatible D-SUB9 preamp integrated HV module. power connector. MCBT can PMT socket: 14 pin PMT (10 stages) process signals from most Power supply: +/- 12V / 20mA common types of scintillation Max HV: 1200 V detectors (NaI(Tl), LaBr3 (Ce), Output impedance: 50 Ω plastic materials and others). GAMWIN Software provides control and display interface.

USB-B connector, Ethernet (RJ45) Micro SD slot (local data storage) Input gain: 0.5x, 1x, 2x, 4x, 8x, 16, 32x High voltage: max. 1100V Preamp power output: +/-12V, +/-24V Power supply: 9V to 30V / 5W DC Conversion Gain: up to 4096 channels

13

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 13 04/02/2016 11:53 Waste Management MEASUREMENT SYSTEMS (NuWM)

From modelling to implementation, Nuvia uses exclusive know-how and state-of-the art technologies in its monitoring systems dedicated to six major fields of application: waste management, homeland security, laboratories, health physics, process continuous monitoring and environmental monitoring.

14

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 14 04/02/2016 11:54 Homeland Radiation Protection Radiation Waste Environmental Security and and Laboratories Monitoring Management Monitoring Civil Defense Decommissioning (NuLAB) Systems (NuWM) (NuEM) MEASUREMENT SYSTEMS (NuHLS) (NuHP) (NuRMS) 16 20 28 36 40 44

15

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 15 04/02/2016 11:54 WASTE MANAGEMENT

16

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 16 04/02/2016 11:54 Measurement Systems Waste Management (NuWM)

NuWM NuWM NuWM NuWM GAMS 1 GAMS 2 GAMS 3 GAMS 4

Mobile in-situ Compact gamma Fully automated Fully automated low gamma spectroscopy spectroscopy waste assay system level waste assay measuring system measuring system system The fully automated High performance and The compact gamma NuWM GAMS 3 The fully automated easy to use mobile assay system NuWM is designed for waste assay system HPGe assay system GAMS 2 is designed characterisation of NuWM GAMS for a wide variety for characterisation medium and high 4 is designed of in-situ gamma- of mid- to high activity radioactive for free release ray measurements activity radioactive waste. The system measurement based providing immediate, waste stored in 200 comes complete on comprehensive accurate, nuclide- litre drums. The with an automatic characterisation specific results. Large measured values are conveyor. The default (radioisotope wheels allow easy used to determine for the system is identification and movement over rough and quantify the a 200 litre drum, quantification) of low- ground, allowing present this capacity is activity radioactive easy transport of the and identify any configurable by the waste stored in 200 entire system to less hotspots present, user. litres drums. The accessible locations. which can then be Detectors: 1 HPGe system includes an Detectors: 1 HPGe further treated. Position of detector: Variable automatic conveyor Position of detector: vertically Detectors: 1 HPGe Weight: <3,000kg with user definable and angle variable Position of detector: capacity. Weight: <100kg Vertically and distance variable Detectors: 3 HPGe Weight: <800kg Position of detector: Fixed Weight: <7,500kg

17

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 17 04/02/2016 11:54 Measurement Systems Waste Management (NuWM)

NuWM NuWM NuWM MUM GEM HIRAM

Advanced fully automated Gamma excavation monitor High Resolution Assay low level waste assay Monitor-trailer mounted system A gross gamma system system capable of real-time assay Advanced fully automated of excavated materials. This The High Resolution low level waste assay system bulk monitoring system has Assay Monitor (HIRAM) NuWM MUM is based on gained UK Environment is a purpose built trailer four high performance HPGe Agency approval for effective comprising a turntable detectors for comprehensive material segregation of powered at 110 volts. The low-activity radioactive waste volumes up to 1m3. Each NuWM HIRAM is fitted with characterisation and free bucket requires a few a high resolution gamma release measurement. seconds to complete a spectrometry (HRGS) system Monitored radioactive waste measurement depending on comprising a detector, multi- is freely stored in measuring detection requirements. Once channel analyser (MCA) and containers. The system completed, a colored light is laptop. The system is utilised capabilities are enhanced automatically illuminated on for the assay of a wide range using especially designed the display to indicate the of waste packages, and can shielding blocks. correct waste steam for the be programmed to apply Detectors: 4 HPGe load. Approximately 350 tons fingerprints and calculate Position of detector: Fixed of material can be measured waste categories in real-time. Weight: <40,000kg and segregated each day. Application: characterization Number of detectors: 1 Features: Battery-operated Position of detector: Fixed Heavy duty frame: 1 m2 footprint Detector type: HPGe Detector: 4 litre plastic scintillation detector and GM probe for high activity This product is offered as a service This product is offered as a service

18

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 18 04/02/2016 11:54 Waste Management (NuWM)

NuWM NuWM RCS MASTAB

Release and control counter Manual sorting table for systems material or waste release Depending on the field of A manual sorting table for application, the various assessment of different kinds release counter systems of waste and materials into offered can be used to inactive and low activity release material from the waste. The system is divided controlled area or to control to three parts: the centre part and administer temporarily contains a detector (large stored waste. volume plastic scintillator) In this selection of products and control unit, the left you find measuring side for the contaminated/ chambers with various sizes active waste, right side for the and shielding thicknesses, « clear » waste. combined with large-area Application: manual sorting material, waste plastic-scintillation detectors Dim. [LxHxW]: 295 x 185 x 200 cm for γ-measurement or thin- Weight: < 1 500 kg layer plastic-scintillation Energy range: 50 - 2000 keV detectors for β-measurement. Number of detectors: 1 The user-specific software is Position of detector: Fixed Detector type: Plastic detector easy to operate and allows SPD32U/500x300x100 nuclide- and object-related calibrations. An integrated balance takes into account the weight of the object to be measured and makes it possible to display the measured values in Bq/g.

19

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 19 04/02/2016 11:54 HOMELAND SECURITY AND CIVIL DEFENSE

20

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 20 04/02/2016 11:54 Measurement Systems Homeland Security and Civil Defense (NuHLS)

NuHLS NuHLS NuHLS AIRIS IRIS SIRIS

Airborne integrated Mobile Integrated Radiation Stand-off radiation radiation monitoring system Monitoring System detection system AIRIS is designed for airborne The IRIS provides continues SIRIS is a newly developed system radiation measurement based radiation measurements for CBRNe and Home Land on gamma spectroscopy. The synchronised with GPS timing Security applications in radiation system can be installed on fix- and location. The collected monitoring. The system provides wing and helicopter platforms. data is ready for mapping and immediate radiation detection, The algorithms provide reporting right after a mission. directional radiation recognition, observed data recalculation IRIS can be installed on any isotopes identification, real-time to the ground level, real-time type of vehicles. It can be set activity calculation of natural identification of selected in a trunk/cargo compartment, and man-made isotopes, radionuclides, control of aircraft roof mounted cargo-rack, customisable notifications and crew safety and intelligent pilot in-cabin installation, etc. The crew safety alarms, and other survey guidance. The mission standard system comprises services. The SIRIS is equipped navigation system is integrated 2xNaI(Tl) detectors; and with built-in UPS that provides with Pilot Guidance Unit optionally a high dose GM up to 4 hours of an independent (PGU). The data acquisition detector. IRIS is a fully auto- operation. The SIRIS data system provides internal data calibrating system with real- acquisition unit (rugged notebook) synchronization and real-time time spectrum stabilisation can be connected to the detection calculation procedures with on natural radionuclide module using wireless or Ethernet precise positioning. A rugged peaks. The data acquisition protocols to provide real-time laptop with Data Acquisition system provides internal data data visualisation and control SW allows the operator to synchronisation, real-time capabilities. The surveillance control all survey parameters, calculation procedures, data results are ready for overlay on a real-time spectra and dose graphic visualization, etc. The map and reporting right after a rate, map-view navigation, detection unit is supplied in a mission. alarms and others. rugged plastic case, equipped MCA resolution: 256-2048 channels E-Resolution: <8.5%@662keV with wheels and a handle. Energy range: 30kev - 3MeV Energy range: 30kev - 3MeV MCA resolution: 256-2048 channels Dose Rate Range: 5nGy/h – 0.2Gy/h Range: 5nGy/h – 0.1Gy/h (with GM) Energy range: 30kev - 3MeV Detectors: 2x4 litres NaI(Tl), 1x neutron LiF6/ZnS detector, 1x energy compensated Detectors: 16 litres NaI(Tl) Dose Rate Range: 5nGy/h – 0.2Gy/h GM detector Detectors: max 2x4 litres NaI(Tl)

21

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 21 04/02/2016 11:54 Measurement Systems Homeland Security and Civil Defense (NuHLS)

NuHLS NuHLS NuHLS IMPAC FIXIS CoMo-170 ZS

Integrated Multi-Parameter Fixed vehicle radiation Hand-held contamination Console monitoring system monitor CBRN version The IMPAC - Integrated FIXIS is mobile radiation • Thin-la yer plastic- Multi-Parameter Console is a monitoring system designed for scintillation detector for real-time data acquisition and fixed installation into vehicles α- and β/γ-contamination navigation system designed and mobile laboratories. The measurement. for airborne and mobile system consists of two high • Operating temperature radiation monitoring as well sensitive plastic scintillator down to -20°C. as environmental science detectors, NaI(Tl) gamma • Suitable for air transport. applications. IMPAC is the spectroscopy detector, high • Supplied with earphones. base of PEI data acquisition for dose rate GM module and • 2 firmware versions any system configuration. The optionally a solid scintillation available (simple version system allows direct and easy neutron detector and for decontamination squad, integration and swapping of weather sensor. The system full version for special task any sensor or measurement provides continuous radiation force). data system. measurements synchronised • Stationary use possible, with GPS timing and position, for example in ECMo whether on the move or at a emergency contamination stationary monitoring location. monitor. The detection system is • > 1,100 CoMo-170 ZS units orientation sensitive for effective supplied to civil defense in localisation of contamination Germany. or illicit or orphaned radioactive • Complete set incl. case. sources. The acquired data is processed in real time, with the results available during the measurement and ready for mapping and reporting right after deployment. Energy range: 30kev - 3MeV Range: 5nGy/h – 0.2Gy/h Detectors: 2x4 litres NaI(Tl), 1x Neutron LiF6/ZnS detector, 1x GM Energy 22 Compensated Detector

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 22 04/02/2016 11:54 Homeland Security and Civil Defense (NuHLS)

NuHLS NuHLS NuHLS PDOSE PGIS PGIS P

Portable and mobile gamma Portable gamma-ray Portable detection system dose rate monitor spectrometer with plastic scintillator Portable monitoring system Portable gamma-ray PGIS P is a highly sensitive for measurement of gamma spectrometer is designed radiation monitoring system, dose rate. The instrument for field and mobile gamma based on spectroscopy detection is designed for portable spectrometry surveillance in with a plastic scintillation and mobile radiation rugged environments. The detector. The PGIS P is designed monitoring including field PGIS detection module can for portable and mobile measurements, selective be equipped with NaI(Tl), radiation surveillance, search sampling and stationary BGO, or optionally LaBr for illicit radioactive sources and monitoring. The detection detectors of various volumes. localisation of contamination module can work in The spectrometer is auto- hotspots. The system provides unattended “Black-Box” calibrated and real-time high sensitivity measurement mode or paired with stablised on natural gamma of gamma dose rate, ground an Andriod based data peaks. The user interface and survey navigation, precise data acquisition mobile device. data acquisition system is synchronisation with GPS and It can be used for long-term Android mobile device based. graphic display of measured monitoring operations. Acquired data is automatically values. The Android control unit The wirelessly connected synchronised with GPS time has a wireless communication via data acquisition system and location. The system Bluetooth. The PGIS P provides provides real-time control provides the user with real-time identification and of the system settings; real-time calculation of the discrimination of man-made and graphical data display; survey concentration of the selected natural radiation based on plastic navigation possibilities, etc. radionuclide identification scintillator spectrum processing It also enables synchronised according to ANSI 42, techniques. The system allows multimedia data comments survey navigation and data the user to add synchronised (photo, video or text) and transmission via GSM channel. multimedia (photo, video and text) real-time data transfer via System enables synchronised comments to the data file. GSM network. multimedia data comments as Plastic Detector: 0.5 up to 4 litres Detector type: 2x energy compensated GM a photo, video or text. Energy range: 50kev - 3MeV Energy range: 50kev – 1.5MeV MCA resolution: 256-2048 channels Basic Range: 10nGy/h – 0.1mGy/h Range: 50nGy/h – 0.2Gy/h Energy range: 30kev - 3MeV Optionally: GM Probe up to 0.2Gy/h Detector: from 0.347 up to 4 litres 23

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 23 04/02/2016 11:54 Measurement Systems Homeland Security and Civil Defense (NuHLS)

NuHLS NuHLS NuHLS RADREFLEX FAMO PORTAL V

Portable contraband Flexible mobile radiation Radiation portal monitoring detector monitor system for vehicles • F or control of hollow • 2 detector units with 2 NaI- Highly sensitive portal spaces, for example in cars, scintillation detectors each. monitor for vehicle scanning to detect hidden goods • NaI-det ector 50 x 50 x 19 mm in industrial applications. like drugs, weapons or with edgewise coupled The system utilises explosives. photomultiplier. industry-proven detectors, • Measur ement system • Digital measuring value sophisticated detection utilises integrated display incl. bar graph and algorithms and advanced, low radioactive source (source optical/acoustic alarm unit. noise electronics technology. activity below permit/ • V ery quick and easy This combination provides a licence requirement). installation on site. perfect solution for vehicle • Radiation source integrated • Can be used as vehicle monitoring applications, in special tungsten monitor, portal monitor, or requiring the lowest possible shielding. body monitor. alarm threshold. System can • No handling and stock be customised and contain license required. various volumes and number • Easy to use (surface of detection panels. scanning). Detectors: 25 litre high-volume • Int egrated measuring object plastic scintillation detectors, default configuration with 2, 3 or 4 detectors library with reference values. (vertically or horizontally oriented) • Sear ch mode supported by acoustic signals.

24

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 24 04/02/2016 11:54 Homeland Security and Civil Defense (NuHLS)

NuHLS NuHLS NuHLS PORTAL D PORTAL P PORTAL U

Emergency deployable Radiation portal system for Universal radiation portal modular radiation screening pedestrian screening monitor system Highly sensitive portal • V arious detector sizes Compact modular emergency monitor for pedestrian (25 l, 17.5 l, 7.5 l). radiation screening system security screening (airports, • Syst em consisting of 2 large- is easily deployable and nuclear facilities, hospitals, area γ-plastic scintillation transportable. Can be quickly public places). System utilises detectors, mounted in and easily deployed in industry-proven detectors, stainless steel housing. emergency. The system is also sophisticated detection • µ-pr ocessor based suitable for general screening algorithms and advanced, measurement electronics, of people and vehicles at low noise electronics PC version also available events with large crowds, at technology. This combination for better visualisation of borders, nuclear facilities and provides a perfect solution measurement values. for other various homeland for pedestrian monitoring, • Aut omatic switching from security tasks. requiring sensitive and background measurement to The system uses high volume reliable system. activity measurement. plastic scintillation detectors Detectors: high-volume 5 litre plastic • Ener gy-selective analysis. - the number and volume of scintillation detectors, configuration with • Alr eady in daily use for the these can be customised. 1 or 2 detectors. scrap and recycling industry, Detectors: high-volume 5 litre plastic nuclear industry and border scintillation detectors, up to 6 detection control. panels (depending on configuration)

25

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 25 04/02/2016 11:54 Measurement Systems Homeland Security and Civil Defense (NuHLS)

NuHLS PORTAL M

Pallet monitor with plastic scintillation detectors • Gat e monitor with 2 detector pillars (left/right). • 1500 cm² plastic scintillation detectors per side. • µ-processor based measuring electronics with LCD. • Results calculated in realtime with adaptive alarm thresholds. • Aut omatic background measurement and subtraction. • F ast response time. • Optical and acoustic alarm functions. • Det ector pillar made of stainless steel / plastic combination. • Stable ramp system for passing through with hand lift truck. Typically used for screening of products at goods-in. Also available with roller conveyor for checking parcels or luggage

26

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 26 04/02/2016 11:54 Homeland Security and Civil Defense (NuHLS)

27

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 27 04/02/2016 11:54 RADIATION PROTECTION AND DECOMMISSIONING

28

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 28 04/02/2016 11:54 Measurement Systems Radiation Protection and Decommissioning (NuHP)

PHOTO ?

NuHP NuHP NuHP CoMo-170 CoMo-170 G CoMo CoMo-300 G DETECTORS Hand-held contamination monitor Mobile contamination External detectors for • Simultaneous and selective monitors CoMo instruments - and / -measurement. α β γ The CoMo-170G and · Flat contamination detector • Illuminated large-area LCD CoMo-300G are more robust ESD-170. • Measur ement values instruments designed for large · End-window contamination displayed in cps, Bq or area monitoring where gam- detector OW5. Bq/cm² as desired. ma is the radiation of interest. · Lar ge-area contamination • Int egrated nuclide library. The instruments come into detector PL-565 • V arious versions and options their own when undertaking · End-window contamination available (e.g. CoMo 300). large area gamma monitoring detector OW20. in situations where you may · Pipe contamination detector have contamination between PD-32 with guiding layers of decontamination elements coatings on walls and ceilings. · V arious other detectors for The 20mm plastic scintillator contamination or dose rate (protected by a 0.6mm alumi- measurement (GM and NaI) nium plate) allows you to peak available. between the layers.

29

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 29 04/02/2016 11:54 Measurement Systems Radiation Protection and Decommissioning (NuHP)

NuHP NuHP NuHP CoMo-170 MF ECMo HFC

Stationary contamination Emergency contamination Hand foot clothing monitor monitor contamination monitor • Single-hand plastic- This specially designed system Stationary contamination scintillation detector is developed to take 4 or 6 monitor (170 cm²). CoMo-170 instruments to • Thin-la yer plastic • Separate wall-mounted provide a simple and stress scintillation detectors. electronics with optional from contamination control • Basic version with 2 hand 3-level LED lamp. point for large groups of people detectors and 2 foot • Illuminated large-area LCD. in an emergency e.g. after a detectors. • Simultaneous and selective nuclear accident • PC-based measuring α- and β/γ-measurement. • Stationary contamination electronics. • Measur ement values monitor made up using • Windows-based user displayed in cps, Bq or portable contamination software. Bq/cm² as desired. monitors. • Optional transponder allows · Integrated nuclide library. • Measurements done in easily traceable measurements to • Also available with understandable steps for an individual. integrated accupack. person being measured. • Network integration • USB interface allows simple possible. display of measurement • Various versions available. values, e.g. traffic light system. • Low-price solution for disaster management. • Significant stress reduction for operator and measured persons compared to manual measurement (i.e. scanning). • Easy height adjustment e.g. for children. • Expansion up to 16 detectors possible, e.g. foot detectors. • Already introduced in German civil protection and disaster management sector. 30

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 30 04/02/2016 11:54 Radiation Protection and Decommissioning (NuHP)

NuHP NuHP NuHP SCINTO WIMP WIMP 60X

High-sensitive gamma Single wipe test counters Multiple wipe test counter radiation monitor To check tools or measuring Everywhere a large number • µ-pr ocessor based instruments used in a of wipe test samples have to measuring electronics. controlled area, but also be measured, the multiple • Int egrated NaI scintillation to check working places wipe test counter WIMP 60X detector, 1 x 1.5”, 1.5 x 2” or in a controlled area, has proved itself. 1.5 x 3” as required. measurements are made The PC-based measuring • Measuring value display in by means of wipe tests. system makes it possible cps or nSv/h or µSv/h. These wipe test samples to evaluate up to 10 • Cust omisable alarm are measured and evaluated samples at the same time. thresholds. in wipe test counters. Our Main advantages are the • Also available with telescopic product line consists of ergonomic and maintenance- extension. microprocessor- and PC- friendly construction as all Main fields of use: based wipe test counters for components are very easy • Scrap metal and recycling 60 mm, 120 mm or 220 mm to access. The software sector. diameter samples. calculates detection limits • Security control of people or Our wipe test counters according to ISO 11929. goods. work with gas-free plastic- Our multiple wipe test • Environmental monitoring. scintillation detectors which counter is also available as evaluate the samples (wipe WIMP 60x6 or WIMP 60x8 test swabs, screening-tests for counting 6 or 8 samples or aerosol filters) separately respectively. for α- and β/γ-radiation. Detection limits are calculated according to ISO 11929.

31

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 31 04/02/2016 11:54 Measurement Systems Radiation Protection and Decommissioning (NuHP)

NuHP NuHP NuHP TOOLMOON DRAMON RCB

Tool contamination monitor High-sensitive radiation Release counter systems control system High-sensitivity For control and release of contamination monitor • Designed for contamination objects from a controlled with γ-plastic scintillation control of tools or for areas: detectors, integrated in a tool assessment of materials at • V ersion with 4 or 6 large- cabinet: goods-in (QA checks). area γ-plastic scintillation • C ontamination control of • Det ection limit approx. 40 detectors, for example in tools used in a controlled Bq based on Co-60 with 4π-geometry. areas. 30 s measuring time. • Measuring chamber shielded • Plastic -scintillation • Det ection limit calculation on all sides with 30mm detectors integrated below according to ISO 11929. low activity lead, internal the cabinet’s surface (tray). • γ -plastic scintillation dimensions from 500 x 500 x • T otal detector surface detectors below and above 560mm (w x D x H). 2760 cm², made up of the drawer. • Integrated scales. 2 detectors. • Shielded system. • As desired with 1 or 2 doors • Shielded by 10 mm lead. • Easy to use, measurement (hatch function). • Measuring electronics with value displayed on LCD • PC-based measuring LCD display integrated in the screen. electronics with user-specific front of the upper drawer. software. • Aut omatic background • Det ection limit < 50 Bq subtraction. based on Co-60 in the centre • All drawers except the upper of the chamber. drawer can be used for • Aut omatic routine for storage of tools. recurring tests. • Det ection limit approx. 100- • Cust omer-specific solutions 150 Bq of Co-60 with 4 s possible. measuring time.

32

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 32 04/02/2016 11:54 Radiation Protection and Decommissioning (NuHP)

NuHP NuHP LARS G LARS W

Large area radiation scanner Large areas contamination Floor contamination monitor measurement system • Lar ge-area γ-plastic This detector lift system scintillation detectors (total has been developed for 2500 cm²). measuring large areas, such • Easy to move on as during decommissioning pneumatic tyres. works at a • Measur ement distance to plant, without requiring floor surface electrically physical strength from adjustable. operators. With this lift • Aut omatic speed calculation system you can move the as a function of the required shielded, collimated NuHP detection limit. LARS W γ-detector over • Ener gy-selective walls and ceilings. Automatic measurement of count rate. measuring cycles are • Definable alarm thresholds. possible. The combination of detector lift with the NuHP LARS W detector has proved itself in daily practice.

33

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 33 04/02/2016 11:54 Measurement Systems Radiation Protection and Decommissioning (NuHP)

NuHP NuHP NuHP LAUMO C LAUMO D LAUMO R

Laundry contamination Laundry contamination Laundry contamination monitor with conveyor belt monitor with drawer load monitor with running rail system system system • Measuring unit made up of • Arra y of 3 x 3 plastic • Double array of 2 x 10 upper and lower detector scintillation detectors (each detectors (each 450 cm²). array. 520 cm²) per drawer. • Plastic -scintillation • 6 plastic-scintillation • Drawer size approx. 1000 x detectors for β/γ- detectors per array. 500 mm, 2 drawers. measurement. • Adjustable distance between • Shielded drawer (30 or • T ransport system moves detector arrays. 50 mm lead). hanging overalls through • Belt speed a function of the • C onstructed from stainless the detector array. required detection limit. steel. • Rail speed as a function of • Stainless steel chain • PC-based measuring the required detection limit. conveyor. electronics with application- • C onstructed from stainless • Settings for specific articles specific software. steel. defined individually. • Int egrated safety features. • PC-based measuring • Automatic background • Syst em size can be adapted electronics with application- measurement and to customer-specific specific software. subtraction. requirements. • Constructed from stainless steel. • Easy to maintain with optimal access to detectors. • PC-based measuring electronics, large-area display. • Integrated safety features.

34

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 34 04/02/2016 11:54 Radiation Protection and Decommissioning (NuHP)

35

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 35 04/02/2016 11:54 LABORATORIES

36

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 36 04/02/2016 11:54 Measurement Systems Laboratories (NuLAB)

NuLAB NuLAB NuLAB FC-25 FNF LBOX

Radiation monitor for simple PC-based food counter with Gamma spectroscopy control of solid and liquid multi-channel analyzer shielding and transport food Sample measurement in containers • Small, low-price measuring Marinelli beaker High quality, low background system. • 2.7 x 2” NaI-scintillation shielding boxes, containers • Integral γ-measurement. detector in lead shielding and accessories for • Calibrat ed for Cs-137, I-131. (30 / 50 mm lead). germanium (high-resolution • Shielded NaI-detector (50 x • PC-system with external gamma spectrometry) and 50 x 13 mm). multi-channel-analyser (USB). scintillation detectors. The • Shielded sample container • Software for nuclide-specific innovative design of the (400 ml). measurement of key nuclides. shielding for the HPGe • Measuring value display in • Spectrum evaluation detectors allows easy access Bq/kg or Bq/l. possible. to the detector and wiring. • Aut omatic background • V olume / weight entry The great advantage of this measurement. possible. shielding is the modular • Det ection limit < 35 Bq/l • Calculation and display of design system which based on Cs-137. the detection limit. simplifies transportation • Measur ement data printout • Int egrated quality control. and handling as it is easy to possible via label printer. • Det ection limit < 10 Bq/l completely disassemble. • V ery easy to use, bought and based on Cs-137 with 30 Shielding: 50 or 100 mm low background successfully used by public. min measuring time. lead (copper and tin coated) • Calibrat ed with certified Metal housing and robust stand DKD sources. • This measuring instrument has established itself in daily use in Japan, after the Fukushima reactor disaster.

37

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 37 04/02/2016 11:54 Measurement Systems Laboratories (NuLAB)

NuLAB NuLAB NuLAB LDIG ASC MORA VAN

Laboratory fume-hoods for Automatic sample changer Mobile radiometric extraction of dangerous for high resolution gamma laboratory fumes, gases and particles spectrometry MORA VAN is fully equipped Extraction of dangerous Automatic sample mobile radiometric fumes and gases during changer for handling up laboratory for environmental hazardous chemical to 60 samples in standard measurement, monitoring processes and in handling configuration. The system and collecting various type of aggressive chemicals. The has been developed for samples. fume hood features a metal automatic counting by This systems are designed housing with safety glass high resolution gamma for monitoring of gamma window, plastic extract, spectroscopy of large and , completed with worktop, numbers of samples for measuring of alpha and beta drains, valves, lighting, long term measurement contamination, measurement wiring, control unit and a or for cases of radiological of photon and neutron cabinet under the hood. emergencies. The system equivalent dose rate and The LDIG can be optionally can operate in full automatic other parameters. High equipped with lead shielding or manual control mode and volume air sampler, water and leaded glass for is remotely controlled by and field sampling set allow radiochemical application. custom software from the PC. operators to take a variety Digitally controlled exhaust Detector: HPGe Efficiency: 50-200% of environmental samples. outlet. Shielding: 50 or 100 mm Pb The radionuclide analyses is Double wall iron hood Duralumin frame based on inbuilt and in-situ Lead shielding app: up to 50mm Barcode sample identification HPGe gamma spectroscopy. Max. exhaust: 1285m3/h (0.5m open) Start-up time: <5min MORA VAN is provided with Pressure loss: 86Pa @ 1000m3/h high sensitive fixed mobile monitoring system. Inbuilt HPGe 50% spec. system with 50mm Pb shielding In-situ HPGe portable system Dose Dose rate and neutron measurement

38

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 38 04/02/2016 11:54 Laboratories (NuLAB)

NuLAB MORA ISO

Deployable radiometric laboratory A laboratory built in a standard ISO 1C type container designed for long-term deployment in the field. The configuration of laboratory and instrumentation is user definable. Inner space is divided into technological, analytical and sample preparation parts. Laboratory is heat insulated, maintaining a constant temperature in the interior and equipped with facilities for laboratory technicians (drinking water, emergency food). Power is available from external source or from own generator and back-up battery. MORA ISO provides the full gamma spectroscopy performance of stationary lab in the field. Various other instruments complement the complexity of monitoring. Detector: 2x HPGe Eff. 50 and 100% Shielding: 50 or 100 mm of Pb In-situ HPGe gamma spectroscopy Dose rate and neutron measurement Start-up time: <60min

39

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 39 04/02/2016 11:54 RADIATION MONITORING SYSTEMS

40

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 40 04/02/2016 11:54 Measurement Systems Radiation Monitoring Systems (NuRMS)

NuRMS NuRMS NuRMS GASEM PRICOM N16

Gamma spectroscopy Gamma spectroscopy System for measurement monitor of noble gases system for monitoring of the of N-16 activity at NPP primary coolant The device is intended System for on-line for gamma spectrometric The system is designed monitoring of N-16 activity measurement for on-line measurement activity for determining of rare gases in nuclear and analysis of the a potential steam power facilities exhausts. spectrometric profile generator leak. N-16 Sampling proceeds via a of the primary coolant activity in the steam bypass and a compressor, in NPPs. A remote circuit is determined that pumps the required semiconductor gamma by the detection of amount of a sample spectrometer enables gamma radiation by the through an aerosol filter and monitoring of nuclear scintillation detection. an iodine filter to a Marinelli fuel leakage (tightness Data processing and beaker. The semiconductor of fuel assemblies). The analysis are undertaken detector and measuring spectrometric route is by spectrometric SW vessel are shielded with located near the pipe where together with advanced low-background lead. the primary coolant flows. autonomous evaluation Results are saved to PC System components: SW, which calculates the summarised, and displayed HPGe detector, processing steam generator leakage as 1 hour and 24 hour electronics, cooling system in l/h. spectra. The system and adjustable collimator Detector type: NaI(Tl) 3x3” identifies the individual (shielding, stepper motors), Communication: Ethernet/USB radionuclides and gross computer for system and Resolution: 8192 channels activity volume in the collimator control. measured air mass. Energy range: 50-2000 keV Energy range: 50-2000 keV Detector type: HPGe Detector type: HPGe NIM electronic or MCA Cooling device & collimators

41

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 41 04/02/2016 11:54 Measurement Systems Radiation Monitoring Systems (NuRMS)

NuRMS NuRMS NuRMS MECOP EGS AREA MU

System for liquid density Auto-controlled volume air RMS display and control monitoring in pipelines sampler unit Equipment for on-line High volume air sampler System designed to display monitoring of density and for ambient environmental the current status of radiation concentration of any liquid monitoring applications. monitoring and dosimetry flowing in piping lines using Sampling of radioactive systems in the local area. The NaI(Tl) detector. The principle aerosols, emissions, air system can display the dose is based on measuring pollutants, dusts etc. rates and dosimetry from radiation attenuation. The Designed to produce: flow all of the connected probes. higher the specific gravity, rates up to 120 m3/h, flow It also allows the user to the higher is the radiation rate adjustment, flow rate and review the status and change attenuation. flow volume measurement, the configuration of any Comes with a Windows user friendly operation, low connected detector. based control unit and weight, remote control, LCD The system provides alarm advanced software package. information panel (current alerts with the exact location Detector: NaI(Tl) status and measured values). of the alarm. Collimator with an exchangeable front Adjustable for various filter All the monitoring data head types. is managed by NuSOFT Air flow up to 120 3m /h DORMIS, our central Interfaces: USB, RS232, RS485, LAN monitoring software.

42

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 42 04/02/2016 11:54 Radiation Monitoring Systems (NuRMS)

NuRMS NuRMS NuRMS AREA SU AREA TU ALMO

RMS measure and display RMS access and personal Multifunctional dose rate unit dosimetry terminal measuring system The NuRMS AREA SU (local The NuRMS AREA TU is Depending on the system simple display unit and a terminal designed for (ALMO-1, -3 or -6), 1 the advanced display and displaying the current to 6 detectors can be alarming unit) are passive status of the radiation and connected. Typically GM components of radiation dosimetry systems, and for detectors are used. We monitoring networks managing access into the offer a complete program designed to display the monitored area. It can be for different measuring current measured values of equipped with different types ranges. The system also connected probes and alarm of dosimeter readers (e.g. accepts NaI-scintillation alerts, where threshold have Thermo Scientific, Mirion) detectors or neutron been exceeded. The unit is RFID or barcode readers for detectors. Depending on the equipped with an information personal identification and requirements, the NuRMS display, and ‘quit’ and ‘test’ personal issue. The system ALMO systems are available buttons. Its alert system has also provides alerts of any as special clean room three information/warning alarms. All the monitoring versions or can be integrated lights and an audible alert. data is managed by NuSOFT into networks for display of All the monitoring data DORMIS, our central measurement values and is managed by NuSOFT monitoring software. alarm indications at a central DORMIS, our central point. monitoring software.

43

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 43 04/02/2016 11:54 ENVIRONMENTAL MONITORING

44

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 44 04/02/2016 11:54 Measurement Systems Environmental Monitoring (NuEM)

NuEM NuEM NuEM RAMS RAMS UW RAMSAT

Environmental radiometric Environmental radiometric Portable dose rate monitoring station station with under water monitoring stations with probe satellite transmission The NuEM RAMS measures ambient dose rate equivalent The underwater monitoring The NuEM RAMSAT radiation and is equipped with an station NuEM RAMS UW is monitoring system is Intelligent NuDET EGM probe designated for environmental designed for operational (GM tubes), or optionally monitoring of water objects. deployment in the field to with a NaI(Tl) gamma System is equipped with provide ambient radiation spectrometric probe weather an intelligent gamma monitoring and assessment station, and a solar panel and spectrometric underwater of radioactive and nuclear batteries for independent probe NuDET ENA UW pollution in the environment operation in the field. Data with NaI(Tl) crystal size 2’’ or work place monitoring for can be transferred via GSM or 3’’. The spectrum is fully radiation safety. The system modem (3G, GPRS, EDGE, and stabilized using the 1460 keV is primarily designed for others) and/or Ethernet (LAN/ peak from K-40. The station measuring ambient dose WLAN/Wi-Fi) and recorded is completed with data equivalent and ambient dose in a central server using processing and transmission equivalent rate. NuSOFT RAMON SW system. unit and various types of Detector: GM tubes Additional stations create a power supplies (batteries, Outdoor stand: Tripod monitoring network suitable solar panels, etc.). Data can Communication: Satellite module be transferred and displayed (optionally radio and GSM), Bluetooth for monitoring an area during module for setup (10 m) a radiation incident. on NuSOFT RAMON, our Probes: NuEM EGM, EPL, ENA central monitoring software. Communication: satellite, GSM, radio, Probes: NuEM ENA UW Ethernet Communication: Satellite, GSM, RF, Power Supply: batteries, solar panel, mains Ethernet supply Power Supply: Batteries, solar panels or mains supply.

45

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 45 04/02/2016 11:54 Measurement Systems Environmental Monitoring (NuEM)

NuEM NuEM NuEM GROUNDHOG GROUNDHOG V GROUNDHOG P

Portable Gamma-Ray Land contamination Land contamination Spectrometer monitoring vehicle monitoring vehicle Goundhog ‘Fusion’: General System is designed for the Vehicle to measure all type purpose technology for detection of particles of of radioactive contamination use as portable or vehicle radioactive material typically with plastic scintillation mounted systems. NaI(Tl) the size of a grain of sand or probes. Mapping grade detectors coupled to an smaller. With five large NaI (Tl) GPS used to calculate the advanced gamma radiation detectors arranged to survey position of every radiation spectrometer mounted in a 2 metre strip in each sweep. measurement with sub- carbon fibre composite cases Detection of Cs-137 particles metre accuracy. 3 5 to reduce weight and improve typically 10 -10 Bq in the top Application: Land mapping the transmission of low- 100-200mm of sand. Synergy This product is offered as a service energy photons. Detector and as above but also equipped spectrometer are connected with eight Insight detectors to an Ultra-Mobile PC carried to improve the efficiency of by the operator or fitted to Am-241 typically to levels of the vehicle. Mapping grade 104-105 Bq in the surface layer GPS used to calculate the of sand. Systems are fitted with position of every radiation advanced ‘alarm’ mechanisms measurement with sub-metre allowing particles to be removed accuracy. Typically used in as detected. Groundhog surveys projects to detect caesium-137 also support remediation distributed in soils at levels of strategies based on in-situ 200-400 Bq/Kg. selective sentencing of waste. Application: Portable & Mobile gamma Survey results can be ‘turned spectroscopy system around’ in less than an hour. This product is offered as a service Application: Land mapping This product is offered as a service

46

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 46 04/02/2016 11:54 Environmental Monitoring (NuEM)

NuEM DRONES G

Gamma detection and spectroscopy module for application on drones The DRONE-G is state-off-the-art technology of NUVIATECH Instruments for light airborne monitoring taking advantage of Drone devices as carriers. The system offers an excellent environmental radiation monitoring performance. It is designed for surveying smaller areas to search for uncontrolled radioactive sources, potential contamination or work in places with hazardous dose level. This module consists of a NaI(Tl) gamma spectroscopy probe, a high dose level detector equipped with two energy compensated GM tubes and a mini air sampler for air contamination measurement. The gamma spectroscopy unit works with spectra with resolution from 256 up to 2048 channels and energy range from 50kev to 03Mev. Typically the module is designed to incorporate NaI(Tl) detectors with dimensions of 2x2 or 3x3 inches. Time and position data synchronized with GPS. Real-time gamma dose rate measurement is based on recalculation from spectrum. Accumulation time is selectable by the user starting from 1sec. The module offers internal data storage in the main unit as well as a wireless real-time data transfer to the control unit (Laptop) with Drone SW application. The operational time with internal battery is about 4 hours. Dose Rate Range: 50nGy – 100mGy/h Resolution: <7% on Cs-137@662keV Energy Range: 50keV – 3MeV Air Sampling: max. 5.2 Litre/min Weight in total: max. 4.5 kg Power: 3x LiPol, 11.1VDC/5100 mAh

47

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 47 04/02/2016 11:54 Product Catalogue PROTECTION DES BÂTIMENTS ET SITES INDUSTRIELS SENSIBLES

www.nuviatech.com [email protected]

NVA-370144-NUVIATECHInstrument-Catalogue-UK-Fev2016.indd 48 04/02/2016 11:54