INFICON Service Tools Please Visit
Total Page:16
File Type:pdf, Size:1020Kb
Service Tools Accessories About INFICON GET INCREASED PERFORMANCE FROM YOUR INFICON PRODUCTS INFICON provides essential gas leak detection products for air conditioning/refrigeration manufacturing and repair, THROUGH THE USE OF THESE SPECIALLY DESIGNED ACCESSORIES. as well as toxic chemical analysis instrumentation for emergency response, security and environmental applications. INFICON products and expertise also provide process-intelligent information for timely decisions in the complex fabrication of semiconductors and thin film coatings for flat-panel displays, solar cells, magnetic and optical storage media, scientific and consumer optics, and architectural glass coatings. TEK-Check™ R134A REFERENCE LEAK – 703-080-G1 Use this reference leak to verify the functionality of your D-TEK Select, Compass or TEK-Mate INFICON has world-class manufacturing facilities in the United States and Europe and subsidiaries in China, Refrigerant Leak Detector. Leak rate of 0.4 oz/yr of R-134a with a lifetime of approximately France, Germany, Japan, Korea, Liechtenstein, Singapore, Switzerland, Taiwan, the United Kingdom and the one year. Small, compact canister easily fits in your leak detector’s carrying case. United States. INFICON is an ISO 9001 registered company. For more information about INFICON and its products, INFICON Service Tools please visit www.inficon.com. A Catalog For Service Professionals Vortex AC OVERFILL PROTECTION DEVICE – 708-203-G1 For use with the Vortex AC Refrigerant Recovery Machine. This kit provides an easily HVAC, REFRIGERATION AND EMERGENCY/SECURITY/ AIR CONDITIONING SOLAR/SEMICONDUCTOR AND installed panel that fits in the front of the Vortex and connects to a cable (provided) that AUTOMOTIVE SERVICE ENVIRONMENTAL REFRIGERATION/AUTOMOTIVE VACUUM COATING PROCESSES plugs into the refrigerant cylinder. This allows for easy, safe recovery of the refrigerant and Laboratory accurate. Maximizing automatic shut-off of Vortex AC when the refrigerant cylinder is 80% full. The cable uses a Toolbox Tough.® Productivity three pin Brad Harrison connector; refrigerant cylinders must be equipped with a refrigerant Assuring quality and Yield. level tank float sensor. (Contact the cylinder manufacturer for more information.) with leak detection. Detect to Protect™ Pilot Plus VACUUM GAUGE MANIFOLD – 710-617-G1 This one-valve manifold assembly comes with a 1⁄4" female flare swivel fitting on top to attach Pilot Plus (or other vacuum gauge) and connect your vacuum pump to the system under evacuation. The center valve isolates all ports and seals vacuum tight. Comes with a large hook so that you can easily hang the manifold in the right spot during use. Call 1.800.344.3304 or visit www.inficonservicetools.com PROTECTIVE HOLSTER CASE – 715-400-P1 for sales and service. Use this custom-molded holster case with the Pilot Plus Vacuum Gauge, Wey-TEK Scale handpiece, or CO Check Carbon Monoxide Meter to provide extra convenience and protection for your tools. The holsters belt clip allows you to keep your instrument handy, and buttons are accessible. The case’s flexible material allows you to easily remove the instrument from the case, if you wish. Whisper ULTRASONIC TRANSMITTER – 711-600-G1 This ultrasonic transmitter for use with the Whisper Ultrasonic Leak Detector provides quick, accurate leak checking in walk-in coolers/freezers, wall and ceiling joints, around doors and With helpful Refrigerant windows, ducts, etc. Turn the transmitter on and place it in the enclosed system you need to Leak Detector selection guide leak check. If the Whisper detects the ultrasonic frequency generated by the transmitter, you will know the presence and location of the leak. Dimensions (L x W x H): 2 1⁄4" x 3 3⁄4" x 1" www.inficonservicetools.com [email protected] Due to our continuing program of product improvements, specifications are subject to change without notice. CO Check, Compass, D-TEK, GAS-Mate, Pilot, TEK-Mate, Vortex AC and Whisper are registered trademarks of INFICON. TEK-Check and Wey-TEK are trademarks of INFICON. All other trademarks are the property of their respective owners. eibe01a1 ©2009 INFICON 17 ® ® D-TEK Select Pilot Plus Manifold Gauge Sets Refrigerant Leak Detector Vacuum Gauge Precise, Dependable Measurement INNOVATIVE INFRARED ACCURATELY MEASURES THE INFICON Pilot Plus Vacuum Gauge incorporates several inno- UNPARALLELED PRECISION vative features for unsurpassed performance. Like the Pilot, TECHNOLOGY DELIVERS ENTIRE VACUUM CYCLE it’s the only gauge to use a Pirani sensor for greater accuracy AND DEPENDABILITY ENHANCED SENSITIVITY and the ability to measure the entire vacuum process, from atmosphere down to one micron. You'll know instantly if your The patented gauge movement in our manifold gauges AND LONG LIFE connections are vacuum-tight. FEATURES AT A GLANCE delivers pulse/vibration free measuring and gauges that can withstand 2 1⁄ 2 times over pressure without damaging the I 0.10 oz/year (3 g/a) sensitivity And Pilot Plus is even more unique: An industry-first filter gauges. The large, easy-to-read gauge face is available in protects the sensor from oil and other contaminants for more I Sensitive to all refrigerants, including R-22, several configurations for your most demanding HVAC/R accurate readings, and saves you from having to clean the R-134a, R-404a, R-410a, R-507 (AZ-50) and all and automotive applications. vacuum sensor. Quick calibration allows you to adjust Pilot CFCs, HCFCs and HFCs Plus for slight variations in atmospheric pressure at your spe- The manifold gauge sets come with a two year warranty, I 1,000-hour infrared cell life for low cost cific geographic location to ensure greater accuracy. You also that’s twice the warranty of any other manufacturer. of ownership get extended battery life of up to 45 hours from one 9V battery, to keep you productive on the job. That’s three times I Manual zeroing ignores user-programmed longer than before. To maximize that battery life, Pilot Plus refrigerant levels when activated shuts down after 60 minutes and saves the last reading for MANIFOLD GAUGE SETS I Infrared cell does not weaken over time, so display again upon the next start up. User-friendly qualities of a large, easy-to-read LCD and included plastic storage case Temperature Scale Aluminum Manifold Gauge Sets Aluminum Manifold Gauge Sets response remains consistent and accurate Ranges 2-way w/Gauge Protectors 4-way w/Gauge Protectors complete the Pilot Plus package. I Infrared cell cannot be overloaded or R12, R134a Automotive 710-612-G11A 710-614-G11A “poisoned” by exposure to large amounts SPECIFICATIONS R22, R134a, R404A 710-612-G21 710-614-G21 of refrigerant R410A 710-612-G31 710-614-G31 Base unit includes 9V battery, filters, storage case R12, R22, R502 710-612-G41 710-614-G41 I High-efficiency air sampling pump provides quick FEATURES AT A GLANCE Battery life 45 hours R22, R410A 710-612-G61 710-614-G61 response and quick clearing (“zeroing”) Power source 9V alkaline battery (included) I Innovative filter protects sensor, eliminates Refrigeration fitting 1⁄4" male flare I On-board diagnostics indicate charging status need for cleaning and warn of low battery or infrared cell failure Controls On/off, unit selection, quick calibration I Operates for 45 hours on one 9V battery Display units microns, Pascal, millibars I NiMH battery is environmentally friendly, won’t I Measures from atmosphere to 1 micron Display range atm (760,000 microns) to 1 micron corrode, and provides greater charging capacity Auto shut-off After 60 min; last reading displayed I Only vacuum gauge using a Pirani sensor when restarted As the first accurate, reliable, highly sensitive, cordless I Enhanced filter design for superior filtration and FEATURES AT A GLANCE for better accuracy refrigerant leak detector, the original D-TEK revolutionized resistance to contaminants Accuracy < 20,000 microns ±5%, > 20,000 microns ±10% of reading the field. Now we have built on that technology leadership I Quick calibration specific to local pressure GAUGE MANIFOLD to create D-TEK Select. This next-generation refrigerant I Ability to run off AC power adapter Resolution (increments) microns: down to 1-micron I Displays in micron, Pascal or millibar Pascal: down to 1-Pa I Pulse/vibration free measuring I Insertion valve for easier metering leak detector uses an innovative infrared absorption sensing I Made in the USA mbar: down to 0.01-mbar 1 cell that is extremely sensitive to all refrigerants—and I ⁄4" refrigerant flare fitting for easy access I 1% accuracy I Maximum overpressure 150 psi (7.76 x 106 microns) Large sightglass for visual contact only refrigerants. I Low battery indicator Warranty 1-year replacement I Withstands 2 1⁄ 2 times over pressure of refrigerant flow I Rebuildable valves, replacement D-TEK Select maintains that sensitivity over time for I Auto shut-off after 60 minutes to conserve battery I Large, 3", easy-to-read gauge face ORDERING INFORMATION consistent, accurate and reliable performance, even with seals available I Plastic storage case included I Pilot Plus 710-202-G1 High and low set gauges the newer refrigerant blends. Best of all, the sensing cell Additional enhancements include a charging status indicator, I Durable metal knobs lasts for approximately 1,000 hours—almost 10 times longer sensor failure indication, and rechargeable NiMH (nickel I Large, easy-to-read LCD display Vacuum gauge manifold 710-617-G1 I Hanging hook 1 Holster case 715-400-P1 I ⁄4" SAE connections than the original D-TEK sensor—to lower your cost of metal hydride) batteries. All in an easy-to-use unit with the I 1-year replacement warranty ownership and improve job site productivity. quality and durability you’ve come to expect from INFICON. I Made in the USA Replacement Parts Carrying case 710-600-G1 Spare filters 710-701-G1 2 HELPFUL REFRIGERANT LEAK DETECTOR SELECTION GUIDE ON PAGE 6.