074-578-P1A Datafid Operating Manual

Total Page:16

File Type:pdf, Size:1020Kb

074-578-P1A Datafid Operating Manual OPERATING MANUAL DataFID™ Flame Ionization Detector IPN 074-578-P1A Warning: Limitation of Liability The ultimate responsibility of the consequences of use of toxic compounds rests with the user. INFICON’s role is as a supplier of instrumentation to assist in the early detection of hazardous conditions involving such compounds. It is vitally important to ensure that the DataFID is maintained in accordance with INFICON’s instructions and that proper calibration is regularly performed. DataFID service should be performed only by INFICON, Inc., or an authorized INFICON repair center. Unauthorized service may void the Intrinsic Safety Certifications. As with any complex device, the DataFID is subject to failure and, while INFICON has taken, and continues to take, all possible precautions to (a) reduce the possibility of failure, and (b) warn the user in the event of failure, circumstances may occasionally occur in which there is a failure despite such precautions on INFICON’s part. INFICON regrets that it cannot accept liability for damages of any kind caused as a result of either failure of the user to follow instructions or of the DataFID to perform. 074-578-P1A 2 Release History Part Number Release Publication Date MN201101-01 A Dec. 23, 2009 B July 20, 2011 C Sept. 19, 2011 D July 31, 2012 074-578-P1 A October 15, 2012 Notices The information contained in this document is subject to change without notice. INFICON makes no warranty of any kind with regard to the material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. INFICON shall not be liable for errors contained herein for incidental or consequential damages in connection with furnishing, performance or use of this material. Copyright © 2012 by INFICON DataFIDTM is a Trademark of INFICON LDARProbeTM is a Trademark of INFICON Windows® is a Registered Trademark of Microsoft Corporation Bluetooth® is a registered Trademark of Bluetooth SIG, Inc. Tedlar® and Teflon® are Registered Trademarks of E.I. du Pont de Nemours & Company, Inc. A component of this device is licensed under U.S. Patent No. 7,369,945 B2 074-578-P1A 3 Table of Contents For Your Safety ............................................................................................................. 7 Notices and Warnings ................................................................................................... 8 FCC Warning ............................................................................................................................ 8 DataFID Intrinsic Safety Notice .............................................................................................. 8 DECLARATION OF CONFORMITY ....................................................................................... 11 1. INTRODUCTION ................................................................................................................. 13 About this Manual ................................................................................................................. 13 UNPACKING THE DataFID .................................................................................................... 14 WARNINGS AND SAFETY PRACTICES ............................................................................... 14 Excessive Heat and Cold .................................................................................................................... 14 Flame Ionization Detector Operation ................................................................................... 15 Detector Response ............................................................................................................................. 16 Support Equipment and Consumables ............................................................................... 17 Compressed Gases ............................................................................................................................ 17 Regulators for Compressed Gases ..................................................................................................... 17 Hydrogen Gas ..................................................................................................................................... 18 Calibration Gas ................................................................................................................................... 18 Oxygen Concentration Limits .............................................................................................................. 18 Flammable Gases ............................................................................................................................... 19 ACCESSORIES ...................................................................................................................... 19 Computer ............................................................................................................................................. 19 Gas Sampling Bag .............................................................................................................................. 19 Charcoal Filters ................................................................................................................................... 19 2. USING THE DataFID ................................................................................................ 21 DataFID Feature Layout ........................................................................................................ 21 LDAR Probe and PDA ......................................................................................................................... 22 Filling the Hydrogen Fuel Cylinder ...................................................................................... 26 Installing the Hydrogen Fuel Cylinder in the DataFID ......................................................................... 33 Attaching the LDARProbe to the DataFID ........................................................................... 34 Basic Operating Instructions ............................................................................................... 34 Calibration .............................................................................................................................. 35 Data Communication ............................................................................................................ 35 Method 21 Operation ............................................................................................................. 35 Response Factors for Gases and Vapors ........................................................................... 36 To use the response factors:............................................................................................................... 36 074-578-P1A 4 Preparing for Field Operation .............................................................................................. 36 Operational Check List ........................................................................................................................ 37 3. USER FUNCTIONS ................................................................................................. 38 Display .................................................................................................................................... 38 Graphic Display ................................................................................................................................... 38 Keys ........................................................................................................................................ 42 Fixed ON/OFF Key .............................................................................................................................. 42 Soft Keys ............................................................................................................................................. 42 Beginning Operation ............................................................................................................. 42 Turning on the DataFID ....................................................................................................................... 42 Default Display .................................................................................................................................... 42 Numeric Value, Duration, Time and Date Entry .................................................................................. 43 System Alerts and Alarms ................................................................................................................... 44 User Interface – Basic Menu ................................................................................................ 44 Passcode ................................................................................................................................ 45 User Modes ......................................................................................................................................... 45 Location Mode ....................................................................................................................... 45 Interval Mode ......................................................................................................................... 46 Method 21 Mode ................................................................................................................................. 47 Logging Off .........................................................................................................................................
Recommended publications
  • Vacuum Instrumentation and Components
    Visionary sensor technology Vacuum Instrumentation and Components The one stop shop for SEMI applications Product Overview CVD PVD ALD Oxidation/Gate Dielectrics EPI Crystal Pulling Ion Implanting Lithography Etch RTP Back end processing PROCESS PRESSURE CONTROL PROCESS PRESSURE CONTROL SYSTEM PRESSURE CONTROL PROCESS PRESSURE CONTROL PROCESS PRESSURE CONTROL • Capacitance Family • Capacitance Family • Capacitance/Pirani/Hot Ion/Cold Cathode Family • Capacitance Family • Capacitance/Pirani Family • Fittings SYSTEM PRESSURE CONTROL SYSTEM PRESSURE CONTROL SYSTEM PRESSURE CONTROL SYSTEM PRESSURE CONTROL • Capacitance/Pirani Family • Cold Cathode/Pirani Family • Capacitance/Pirani/Hot Ion/Cold Cathode Family • Capacitance/Pirani/Hot Ion/Cold Cathode Family INFICON VACUUM GAUGES AND COMPONENTS AT A GLANCE • Fittings • Fittings • Fittings • Fittings • Heated Components • Highy accurate pressure measurement instrumentation • Wide range combination gauges • Large variety of high quality vacuum fittings CAPACITANCE DIAPHRAGM GAUGEE STRIPE EDGE GEMINI PIRANI CAPACITANCE HEATED PORTER SKY SKY HEATED CDG045Dhs – CDG045D2, CUBE COLD CATHODE GAUGE COMBINATION GAUGE PIRANI HOT ION GAUGE COMPONENTS CDG020D CDG025D CDG045D –CDG200D CDG200Dhs CDG100D2 CDGsci MAG500, MPG500 PCG55x PSG5xx BPG, BCG, HPG FITTINGS AND ASSEMBLIESES • More gauge • Unprecedented • Excellent long term • Faster than 1 ms • Smallest instrument • True high precision • Long lifetime in harsh • Double sensor technology • Stainless steel • Triple sensor technology • Competitively priced
    [Show full text]
  • Leak Detection 2016 CATALOG
    Leak Detection 2016 CATALOG Contents General Applications ................................................................ 3 Products T-Guard.................................................................... 4 LDS3000................................................................... 6 Modul1000 ................................................................. 8 Calibrated Leaks for System Applications........................................ 10 Pernicka 700H ............................................................. 12 UL1000................................................................... 14 UL1000 Fab ............................................................... 16 UL5000................................................................... 18 Accessories for Vacuum Leak Detectors ........................................ 20 Connection Components ..................................................... 22 Calibrated Leaks for Vacuum Applications ....................................... 23 Protec P3000 (XL) . 24 Ecotec E3000 .............................................................. 26 Ecotec E3000A............................................................. 28 HLD6000 ................................................................. 30 Calibrated Test Leaks for Sniffer Applications .................................... 32 IRwin .................................................................... 34 Contura S400 .............................................................. 36 Sensistor Sentrac..........................................................
    [Show full text]
  • RC1000 English.Book
    OPERATING INSTRUCTION lina15e1-d (1202) Catalog No.: 551-010 551-015 from software version V1.4 RC1000 Remote control for leak test equipment Imprint INFICON GmbH Bonner Straße 498 50968 Köln Germany Copyright© 2011 INFICON GmbH, Cologne. This document may not be reproduced in any form without the permission of INFICON GmbH, Cologne. 2 Content 1 Operating instructions 5 1.1 How to use this manual 5 1.2 Warning and danger symbols 5 1.3 Glossary 6 2 Important safety instructions 7 2.1 Intended use 7 2.2 User requirements 7 2.3 Restrictions of use 8 2.4 Hazards in the event of intended use 8 3 Description of the RC1000 13 3.1 Use 13 3.2 Operating Elements 14 3.3 Back of the RC1000 16 3.4 Supplied equipment 17 4 Installation 18 4.1 Connection to the leak detector 18 4.2 Connecting radio transmitter and leak detector 19 4.3 Inputs and outputs 20 4.4 Wall plug-in power supply 22 5 Operating the remote control 24 5.1 Starting up the RC1000 24 5.2 Touch display operation 25 5.3 Main menu for configuration 27 5.3.1 Buttons with basic functions 28 5.3.2 Connecting / disconnecting (RC1000WL) 29 5.3.3 Setting the trigger level 30 5.3.4 Scale: scaling of the leak-rate curve 31 5.3.5 Sound volume 33 5.3.6 Recorder 34 5.3.7 Info: device information 36 5.3.8 Miscellaneous 37 5.3.8.1 Language selection: 37 Content 3 5.3.8.2 Energy-saving options (RC1000WL) 38 5.3.8.3 Set Time and Date 39 5.4 Operating the leak detector 40 5.5 Paging function 42 6 Maintenance tasks 43 6.1 Spare parts 43 6.2 Maintenance 43 6.3 Cleaning 44 7 Transport and disposal 45 7.1 Transporting 45 7.2 Disposal 45 8 Technical Data 46 8.1 Weight / dimensions 46 8.2 Characteristics 46 8.3 Environmental Conditions 47 8.4 Mains power for wall plug-in power supply 47 8.5 Wireless permits of RC1000WL 47 9 Ordering information 48 10 Declaration of conformity 48 11 Worldwide service centres 51 Index 56 4 Content 1 Operating instructions 1.1 How to use this manual • Please read this manual before commissioning the wireless RC1000WL or the wire-bound RC1000C remote control.
    [Show full text]
  • INFICON 2020Combopro.Pdf
    Exceptionally Simple – Intrinsically Safe 2020ComboPRO™ Portable Photoionization Detector Portable Photoionization Detector for VOC measurement The INFICON 2020ComboPRO portable photoionization SMALL ENOUGH TO TAKE ANYWHERE detector (PID) provides versatility for overall volatile organic The instrument weighs a mere 1.9 lb., and is small enough to compound (VOC) monitoring in environmental, emergency carry and operate with one hand. Despite its small size, the response and industrial hygiene applications. Designed with 2020ComboPRO is equipped with a large graphical display field professionals in mind, the 2020ComboPRO is small, that is easy to read, even when wearing a full-face respirator. lightweight, and easy to use. The large keypad buttons are easily accessed even with heavy hazmat gloves. WHEN RAPID RESULTS ARE VITAL HazMat and emergency response teams require portable, PROVEN PID TECHNOLOGY reliable instruments to quickly characterize spills and COUPLED WITH FLEXIBILITY contaminated sites. The 2020ComboPRO provides sample The 2020ComboPRO represents the newest advancement in analysis and results in less than three seconds. Rapid results volatile organic compound (VOC) measurement coupled with are vital to responder safety to determine the level of personal operational simplicity. It measures a wide variety of chemicals protective equipment (PPE) required, and the appropriate for environmental, industrial hygiene, and emergency response clean-up actions. Fast evaluation of the contamination present applications. The 2020ComboPRO can monitor a broad range is also crucial to determine the hazard to the surrounding of compounds with the 10.6 eV lamp or the optional 11.7 eV community and to establish a safety perimeter around the site. lamp. Plus, with a quick connect pre-filter tube assembly, it can measure benzene, a critical compound to identify in SAFE ENOUGH FOR EVEN THE MOST many environmental and industrial monitoring activities.
    [Show full text]
  • List of Section 13F Securities
    List of Section 13F Securities 1st Quarter FY 2004 Copyright (c) 2004 American Bankers Association. CUSIP Numbers and descriptions are used with permission by Standard & Poors CUSIP Service Bureau, a division of The McGraw-Hill Companies, Inc. All rights reserved. No redistribution without permission from Standard & Poors CUSIP Service Bureau. Standard & Poors CUSIP Service Bureau does not guarantee the accuracy or completeness of the CUSIP Numbers and standard descriptions included herein and neither the American Bankers Association nor Standard & Poor's CUSIP Service Bureau shall be responsible for any errors, omissions or damages arising out of the use of such information. U.S. Securities and Exchange Commission OFFICIAL LIST OF SECTION 13(f) SECURITIES USER INFORMATION SHEET General This list of “Section 13(f) securities” as defined by Rule 13f-1(c) [17 CFR 240.13f-1(c)] is made available to the public pursuant to Section13 (f) (3) of the Securities Exchange Act of 1934 [15 USC 78m(f) (3)]. It is made available for use in the preparation of reports filed with the Securities and Exhange Commission pursuant to Rule 13f-1 [17 CFR 240.13f-1] under Section 13(f) of the Securities Exchange Act of 1934. An updated list is published on a quarterly basis. This list is current as of March 15, 2004, and may be relied on by institutional investment managers filing Form 13F reports for the calendar quarter ending March 31, 2004. Institutional investment managers should report holdings--number of shares and fair market value--as of the last day of the calendar quarter as required by Section 13(f)(1) and Rule 13f-1 thereunder.
    [Show full text]
  • Inficon Announces Matthias Troendle As New Cfo Zurich
    Corporate Contact European Contact Betty Ann Kram Bernhard Schweizer Director of Global Communications sensus PR GmbH +1.315.434.1122 +41.43.366.5511 [email protected] [email protected] INFICON ANNOUNCES MATTHIAS TROENDLE AS NEW CFO ZURICH, Switzerland/SYRACUSE, New York — June 23, 2008 —INFICON (SWX Swiss Exchange: IFCN), a leading provider worldwide of instrumentation and process control software for advanced industrial vacuum processes, today announced the appointment of Matthias Troendle as Chief Financial Officer, beginning September 1, 2008. Mr. Troendle succeeds Peter G. Maier, who accepted the position of President, Intelligent Sensor Solutions Business Unit, last December and continues to serve as CFO until August 31, 2008. Matthias Troendle is a German citizen born in 1960. He studied finance and materials management at the Berufsakademie Mannheim and holds a bachelor’s degree in economics. From November 1995 until today, Mr. Troendle held several positions within Solectron Corporation (sales: BUSD 11, employees: 50,000) serving as Senior Director Finance Europe since June 2003. Between July 1988 and October 1995, he worked for Hewlett Packard GmbH in Böblingen, Germany, in various positions within the main finance department. Earlier in his career, Mr. Troendle worked for Digital Equipment Corporation (DEC) in Stuttgart, Germany, as Financial Analyst. ### ABOUT INFICON INFICON is a leading, provider of innovative instrumentation, critical sensor technologies, and advanced process control software that enhance productivity and quality in sophisticated industrial vacuum processes. These analysis, measurement and control products are essential for gas leak detection in air conditioning/refrigeration manufacturing and vital to original equipment manufacturers (OEMs) and end-users in the complex manufacturing of semiconductors, flat panel displays, magnetic and optical storage media, and precision optics.
    [Show full text]
  • UL1000 Fab Mobile Helium Leak Detector ULTRATEST® Sensor Technology
    UL1000 Fab Mobile Helium Leak Detector ULTRATEST® Sensor Technology The “Dry” Standard for Vacuum Leak Checking The “dry” standard for vacuum leak testing The INFICON UL1000 Fab Helium Leak Detector is the renowned TYPICAL APPLICATIONS standard when it comes to economic n Industrial vacuum equipment helium vacuum leak testing in manufacturing with high demand for cleanliness industrial or semiconductor environments. n Vacuum components or sub- assemblies before they are Potential contamination of the tested installed in existing tools parts or equipment by carbon- hydrogen compounds or particles is n Maintenance work on vacuum eliminated through the instrument’s dry tools, with or without support from pump technology. The UL1000 Fab their own pump provides the best compromise between n Inspections and installations of high performance, unparalleled process gas systems robustness, and affordability. It provides state-of-the-art detection limits of n Semiconductor, flat panel display or solar cell manufacturing 10-12 mbar·l/s combined with reasonable short pump down and response time. The compact design provides high maneuverability allowing easy access to maintenance areas with restricted space. The selectable background suppression (I·ZERO) enables continuous leak testing within at least two decades lower than existing background levels. All features enable you to shorten the time of your leak testing efforts while assuring that all leaks can be identified at an economic scale. ADVANTAGES AT A GLANCE n Minimize leak testing efforts n Enable
    [Show full text]
  • Stripetm Cdg045dhs, Cdg100dhs, Cdg160dhs, Cdg200dhs High Speed Vacuum Gauge
    Visionary Sensor Technology StripeTM CDG045Dhs, CDG100Dhs, CDG160Dhs, CDG200Dhs High Speed Vacuum Gauge Smart Inside – Fast Outside CDG working principle Advanced heating concept Flexible integration fast readout Higher productivity Standard Stripe Direct pressure measurement • Temperature stabilized at ± 0.1°C Stripe CDG045Dhs, CDG100Dhs, by diaphragm p • Innovative insulation material - touchable surface at 200°C ΔCΔC Δd ~ p p 60°C - small footprint CDG160Dhs, CDG200Dhs Vacuum Gauge Capacitance readout • Immune to ambient environment Δd • SEMI S2 compliant 1 200°C ~ p • Excellent temperature stability ΔC p • Low power consumption • Fast warm up Settling time p Electrode Diaphragm p = pressure dead time Fully ceramic sensor Enabling process innovation Bonded ceramic structure combined with digital signal processing provides superior measurement performance. Si Standard Stripe Increased layer quality Process pressure settling time INFICON Stripe high-speed Capacitance Diaphragm Gauges are the fastest, highly accurate vacuum measurement instru- ments available. With a less than 1ms response time combined with the EtherCAT fieldbus interface it opens up a total new field of applications. The proven temperature controlled, corrosion resistant, ultra-pure ceramic sensor provides superior Gauge protection for increased lifetime Any mounting orientation Low noise /Advanced Pressure Control span stability over many years paired with state-of-the-art zero stability. Stripe Standard Level 1 Baffle U U Stripe comes with the INFICON patented unique sensor shield which protects the gauge from undesired process by-products. Stops coating, particles INFICON Stripe using an innovative heating concept, which provides a cool to the touch surface, and its unique speed Level 2 Heater capabilities, enabling an unprecedented productivity increase, making it the most advanced vacuum instrument of its kind.
    [Show full text]
  • Skywater Technology Foundry Selects INFICON's Optimization
    SkyWater Technology Foundry Selects INFICON’s Optimization Software to Enable Real-Time Operational Visualization and Improved Performance Syracuse, NY and Bloomington, MN, January 28, 2019 — SkyWater Technology Foundry, the industry’s most advanced U.S.-based and solely U.S.-owned Trusted Foundry, has selected INFICON, a leading provider of Smart Manufacturing and process monitoring solutions to the global semiconductor industry, to provide factory performance visualization and work-in-process (WIP) scheduling and move optimization using its Final Phase Systems (FPS) suite of applications. The software systems provided by INFICON enable factories to increase productivity and/or capacity with existing capital and human resources. By adopting Smart manufacturing practices, companies such as SkyWater can move beyond traditional factory dispatching by using intelligent scheduling and delivery methods to optimize WIP flow throughout the factory. With the INFICON FPS productivity products, SkyWater will be able to increase overall tool utilization and drive down cycle time, maximizing the ROI of its existing infrastructure. “Our Technology Foundry operation is complex and encompasses a high mix production flow and wide-ranging R&D activities. We are investing in INFICON’s FPS software solution to enhance our manufacturing monitoring capabilities and improve operational efficiency which help ensure premium quality and on time delivery for our customers,” said Tom Legere, Senior Vice President of Operations. “Our Advanced Scheduling and Next Move Software Solutions are ideal for companies like SkyWater that have a dynamic manufacturing environment. By providing real-time operational visibility and a fab-wide optimized WIP schedule, we improve manufacturing efficiencies such as tool utilization and cycle time,” said John Behnke, General Manager of INFICON’s FPS product line.
    [Show full text]
  • 2020 Half-Year Report
    HALF-YEAR REPORT 2020 Company Overview INFICON provides world-class instruments for gas Company Overview 1 analysis, measurement and control. Key Figures 2 Group Organization 4 These analysis, measurement and control products are essential for gas leak detection in air conditioning, Financial Review 5 refrigeration, and automotive manufacturing. Consolidated Interim Balance Sheet 7 Consolidated Interim Statement of Income 8 They are vital to equipment manufacturers and Consolidated Interim Statement of Shareholders’ Equity 9 end-users in the complex fabrication of semiconductors and thin film coatings for optics, flat panel displays, Consolidated Interim Statement of Cash Flows 10 solar cells, LED lighting, and industrial vacuum coating Notes to Consolidated Interim Financial Statements 11 applications. Other users of vacuum based processes include the life sciences, research, aerospace, food and general packaging, heat treatment, laser cutting, oil and gas transportation and processing, alternative energy, utilities, and many other industrial processes. We also leverage our expertise to provide unique, toxic chemical analysis products for emergency response, security, and environmental monitoring as well as instruments for energy and petrochemical applications. INFICON publishes its half-year report online. This edition has been optimized for easy reading on your computer and mobile devices. Additional copies of this report may be downloaded from the Investors section of our website, www.inficon.com, Investor section 1 Key Figures –
    [Show full text]
  • Modul1000 Modular Leak Detector Operating Manual Operating (1309)
    OPERATING MANUAL jinb80e1-h (1309) Translation of the original manual Catalog-No. 550-300A 550-310A 550-330A from software version V1.74 Modul1000 Modular Leak Detector Operating Manual Operating (1309) Legal notice INFICON GmbH Bonner Straße 498 50968 Cologne Germany Copyright© 2010 INFICON GmbH, Cologne. This document may only be reproduced in any form with the permission of INFICON GmbH, Cologne. jinb80e1-h 0-2 Content 1 Operating instructions 1-5 1.1 How to use this manual 1-5 1.2 Warning and danger symbols 1-5 1.3 Graphic conventions 1-6 Operating Manual Operating 1.4 Definition of Terms 1-6 2 Important safety instructions 2-1 2.1 Intended use 2-1 2.2 User requirements 2-1 2.3 Restrictions of use 2-2 2.4 Hazards in the event of intended use 2-2 3 Description of equipment 3-1 3.1 The housing 3-1 3.2 Interfaces 3-3 3.3 Operating options 3-3 3.3.1 Desktop operation 3-4 3.3.2 Installation in switch cabinet 3-4 3.3.3 Remote control RC1000 3-5 3.4 Scope of delivery 3-6 3.5 Accessories 3-6 3.5.1 Sniffer line SL200 3-6 3.5.2 Test chamber TC1000 3-6 3.5.3 Set of male connectors for Interfaces 3-7 4 Installation 4-1 4.1 Mechanical Installation 4-1 4.2 Electrical installation 4-1 4.2.1 Mains socket 4-1 4.2.2 Electrical interfaces 4-2 4.2.3 Vacuum connections 4-6 (1309) 5 Working Modes 5-1 5.1 Vacuum 5-1 5.2 Partial Flow Mode 5-2 5.3 Auto Leak Test 5-3 5.3.1 Auto Leak Test Settings 5-3 5.4 Commander mode 5-4 5.4.1 Design of a leak detector system 5-5 5.4.2 Test sequence of events 5-6 5.5 Sniff mode tips 5-8 jinb80e1-h Content 1-1 6 Operation
    [Show full text]
  • Company Overview Customers Recent Company Highlights Stock Price Metrics Trends in the Semiconductor Industry Growth Opportuniti
    SWX Swiss Exchange: IFCN As of September 24, 2007 COMPANY OVERVIEW TRENDS IN THE SEMICONDUCTOR INDUSTRY INFICON is a leading developer, manufacturer and supplier of Change is a constant in the semiconductor industry. Today’s market innovative instrumentation, critical sensor technologies, and is driven by the increasing electronic content in many products and the advanced process control software for the semiconductor and rising demand for speed, power and miniaturization of these products. vacuum coating industries and other industrial applications. These Smaller, faster chips for portable electronic devices and the migration analysis, measurement and control products are vital to OEMs and to below 65-nanometer (nm) for chip manufacturing require even more end-users in the complex manufacturing of semiconductors, flat complex processes and new materials. In addition, as the industry panel displays, magnetic and optical storage media and precision transitions to below 65-nm processes, new technological challenges optics. INFICON also provides essential instrumentation for gas such as power and heat dissipation issues arise. leak detection to the air conditioning/refrigeration industries and toxic chemical analysis for the emergency response and security As the cost of silicon wafers from which the integrated circuit is markets. manufactured and the complexity of the manufacturing processes To strengthen its position in key semiconductor markets, increases, the requirement for faster detection of faults in the process INFICON has established a worldwide sales and marketing becomes more critical. This is driving the rapid adoption of advanced infrastructure in strategic regions, such as Asia Pacific. The process control (APC) and early fault detection in the semiconductor company is expanding its existing strong sales presence in China to industry – needs INFICON technology solutions and process expertise take advantage of that country’s ambitious plans for becoming a directly address.
    [Show full text]