6. Distillation, Separation, Filtration Distillation, Synthesis/Components for Extraction

Total Page:16

File Type:pdf, Size:1020Kb

6. Distillation, Separation, Filtration Distillation, Synthesis/Components for Extraction GENERAL CATALOGUE EDITION 20 6. Distillation, separation, filtration Distillation, synthesis/Components for Extraction 1 Separating funnels with screw cap, Type 4301, FEP 1 Transparent. Teflon® FEP, Tefzel® ETFE stopcock and ETFE screw cap. Impact resistant. Thermo Scientific Non-wetting surfaces ensure no liqiud residue adhesion. Chemically stable. Length of stem under stopcock 65 mm. Autoclavable. Type Capacity Screw cap PK Cat. No. diam. ml mm 4301 125 28 1 9.203 531 4301 250 33 1 9.203 532 4301 500 43 1 9.203 533 4301 1000 53 1 9.203 534 4301 2000 53 1 9.203 535 Teflon® and Tefzel® are registered trademark of DuPont. 2 Separating funnel holder PP 2 Manufactured from best quality polypropylene. Suitable to hold all types of laboratory ISOLAB funnels and also separatory funnels with diameter up to 150 mm. Two tapered wedges are provided to ensure firm grip. Description PK Cat. No. Separating funnel holder 1 9.251 559 Support ring please see page 169. 3 Water estimator to Dean Stark, borosilicate glass 3.3 3 Manufactured from borosilicate glass 3.3 according to DIN 12420. Suitable for xylol ISOLAB method. System completed with 500 ml (NS 29/32) flask + Liebig condenser with jacket length 400 mm + measuring tube (10:0.1 ml) with PTFE stopcock. Description PK Cat. No. Water estimator to Dean Stark 1 9.303 005 4 Extractors acc. to Knöfler-Böhm, DURAN® tubing 4 The condensate passes the extraction sample and flows back into the flask continuously Lenz without interrupting the extraction process, i.e. the solvent is recirculated continuously. The complete apparatus consists of: Jacketed extractor head made of DURAN® tubing, Dimroth condenser with thread GL 14, made of DURAN® tubing, Round bottom flask material: DURAN® Round bottom flasks Extractor Condenser PK Cat. No. Capacity ml ml NS 100 30 29/32 1 6.237 313 250 150 45/40 1 6.237 312 500 250 45/40 1 9.043 010 1000 500 60/46 1 9.043 020 5 Soxhlet extractors, without stopcock 5 Borosilicate glass 3.3 which is resistant to heat and almost all chemicals. They meet the ISOLAB highest quality standards according to DIN 12602. Capacity Cone Socket PK Cat. No. mlwww.wenk-labtec.comNS NS 30 29/32 29/32 1 4.008 417 70 29/32 34/35 1 4.008 418 100 29/32 45/40 1 4.008 419 150 29/32 45/40 1 4.008 420 250 29/32 45/40 1 4.008 421 500 29/32 45/40 1 6.243 673 For complete distillation system please see page 1252. www.wenk-labtec.com E & OE. 627.
Recommended publications
  • Extractables and Leachables Extraction Techniques
    expert analytical testing Extractables and Leachables Extraction Techniques Second Edition A collection of articles designed to help improve your knowledge and skills. TABLE OF CONTENTS P.03 INTRODUCTION P.04 SONICATION P.05 REFLUX P.07 SOXHLET P.10 SEALED VESSEL P.11 PRESSURISED SOLVENT EXTRACTION P.14 MICROWAVE ASSISTED EXTRACTION P.16 SUPERCRITICAL FLUID EXTRACTION (SFE) P.19 OVEN EXTRACTION P.22 LIQUID EXTRACTION SURFACE ANALYSIS (LESA) P.24 DIRECT ANALYSIS IN REAL-TIME (DART) & DESORPTION ELECTROSPRAY IONISATION (DESI) P.27 HEADSPACE P.29 THERMAL DESORPTION P.30 SUMMARY P.31 CONCLUSION INTRODUCTION In extractable and leachable studies there are a range of extraction techniques that can be used to either produce a solution for further analytical study or directly analyse the materials. A selection of the most common extraction techniques are listed in Table 1. Each of the techniques will then be discussed, detailing what is involved to set up the equipment, the advantages and disadvantages as well as some of the limitations of each technique. The primary aim of any extractable study is the acceptance or rejection of a given material. The acceptance or rejection can only be achieved with knowledge. This can be achieved by a number of ways, including; understanding of the materials likely composition, manufacturers information and the definitive testing. In all aspects of extractable testing it is important to remember that the extraction is not so vigorous as to deform or degrade the material which would likely produce extractables that will not be observed as leachables. Extractables are potential leachables, it is the leachables that the patient is exposed to and are of toxicological concern.
    [Show full text]
  • Science Catalogue
    Science Catalogue Gurudutt Shaleya Sahitya Shop No 6, 8 & 9 DSK Chintamani Complex Pune – 411030 Phone: (020) 64006566 09372646566; 07030456566; 08600044877 09822815360; 07030756566 Email: [email protected] Website: www.guruduttshaleyasaahitya.com General Lab Equipment 1-25 This category comprises of Complete range of General Lab products used in Educational departments worldwide i.e. Physics, Chemistry, Biology Educational Lab Products. Analytical Lab Equipment 26-34 Browse through this category for extensive range of Research Lab Products like Spectrophotometers, Centrifuge Machines, Lab Balances & Scales, Incubators & Ovens, pH meters, Testing Kits, Autoclaves, Laminar Air Flow Cabinet and Fume Hoods etc. used extensively in Research Labs in Universities, Quality Control Labs in various Industries around the globe. Lab Glassware (Borosilicate) 35-39 Laboratory Glassware made from High Quality Borosilicate 3.3, Packed well in die cut boxes in durable packaging. Also includes Laboratory Apparatuses/ Equipments like Distillation/Digestion Apparatus, Rotary Evaporators etc. Quartz & Silica Labware also available. Microscopes, Accessories & Cameras 40-43 Wide Range of High Quality Microscopes from Research Biological to Metallurgical, Polarizing and Stereozoom Microscopes. We can even customize microscopes as per customer requirements/tender specifications. Laboratory Plasticware 44-47 With stringent quality control we have been exporting high quality Laboratory Plasticware made from best quality raw material like Beakers, Cylinders,
    [Show full text]
  • Improved Automatic Steam Distillation Combined with Oscillation-Type
    Lachenmeier et al. SpringerPlus (2015) 4:783 DOI 10.1186/s40064-015-1574-6 METHODOLOGY Open Access Improved automatic steam distillation combined with oscillation‑type densimetry for determining alcoholic strength in spirits and liqueurs Dirk W. Lachenmeier1* , Leander Plato1, Manuela Suessmann1, Matthew Di Carmine2, Bjoern Krueger3, Armin Kukuck3 and Markus Kranz3 Abstract The determination of the alcoholic strength in spirits and liqueurs is required to control the labelling of alcoholic bev- erages. The reference methodology prescribes a distillation step followed by densimetric measurement. The classic distillation using a Vigreux rectifying column and a West condenser is time consuming and error-prone, especially for liqueurs that may have problems with entrainment and charring. For this reason, this methodology suggests the use of an automated steam distillation device as alternative. The novel instrument comprises an increased steam power, a redesigned geometry of the condenser and a larger cooling coil with controllable flow, compared to previously available devices. Method optimization applying D-optimal and central composite designs showed significant influ- ence of sample volume, distillation time and coolant flow, while other investigated parameters such as steam power, receiver volume, or the use of pipettes or flasks for sample measurement did not significantly influence the results. The method validation was conducted using the following settings: steam power 70 %, sample volume 25 mL trans- ferred using pipettes, receiver volume 50 mL, coolant flow 7 L/min, and distillation time as long as possible just below the calibration mark. For four different liqueurs covering the typical range of these products between 15 and 35 % vol, the method showed an adequate precision, with relative standard deviations below 0.4 % (intraday) and below 0.6 % (interday).
    [Show full text]
  • Petrochemical
    PETROCHEMICAL Designed from ASTM specifications, petrochemical glassware from Kimble® is intended for use with standard ASTM test methods. Petrochemical apparatus includes distillation flasks, centrifuge tubes, and glassware unique for testing petroleum products. ons precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions preci lassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware ons precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions prec on glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassw olutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions on glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions precision glassware solutions www.kimblechase.com solutions precision g l l l l l l l l l l l l l PETROCHEMICAL 2 CONTENT CATEGORIES PAGE(S) ADAPTERS 3 BEVEL-SEAL™ ASTM METHODS 19 Search Catalog by ASTM Methods BEAKERS 3 Low Form Griffin,
    [Show full text]
  • 216175321.Pdf
    Nanostructured Ni2P as an Electrocatalyst for the Hydrogen Evolution Reaction Eric J. Popczun,1 James R. McKone,2 Carlos G. Read,1 Adam J. Biacchi,1 Alex M. Wiltrout,1 Nathan S. Lewis,2* Raymond E. Schaak1* 1 Department of Chemistry and Materials Research Institute, The Pennsylvania State University, University Park, PA 16802. 2 Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA 91125. Materials and Methods Chemicals and Materials. Nickel(II) 2,4-pentanedionate [95%, Ni(acac)2] (Alfa-Aesar) and tri-n- octylphosphine [tech. 85%, P(C8H16)3, Lot #ROY7AGE] (TCI America), as well as oleylamine [tech. 70%, C18H37N, Lot #BCBG1298V], 1-octadecene [tech. 90%, C18H36, Lot #MKBH2370V], titanium foil [99.7%, 0.25 mm thickness], sulfuric acid [99.999%], and Nafion-117 solution [5% in a mixture of lower aliphatic alcohols and water] (Sigma-Aldrich),were used as received. High-quality colloidal Ag paint was purchased from SPI Supplies. Two-part epoxy [HYSOL 9460] was purchased from McMaster-Carr, and Nafion was purchased from FuelCellStore.com. Synthesis of Ni2P nanoparticles. Caution: Because this procedure involves the high-temperature decomposition of a phosphine that can liberate phosphorus, this reaction should be considered as highly corrosive and flammable, and therefore should only be carried out by appropriately trained personnel using rigorously air-free conditions. Ni(acac)2 (250 mg, 0.98 mmol) was added to a 50-mL three-necked, round bottom flask containing a borosilicate stir bar. The flask was also equipped with a thermometer adapter, thermometer, Liebig condenser, and rubber septum. Prior to sealing the flask, 1-octadecene (4.5 mL, 14.1 mmol), oleylamine (6.4 mL, 19.5 mmol), and tri-n-octylphosphine (2 mL, 4.4 mmol) were added to the vessel.
    [Show full text]
  • Diagrams Subject: Chemistry Year 10 Autumn Term—C2.1 Purity An
    Section A: Key Vocabulary Subject: Chemistry Year 10 Autumn Term—C2.1 Purity and Separating Mixtures Tier 3 vocabulary Definition Relative atomic The mean mass of an atom of an element Section B: Microscopes Section C: Diagrams mass (Ar) compared to 1/12 the mass of a 12C atom. Relative formula The mean mass of a unit of a substance Relative formula mass and Empirical formulae Filtration and Crystallisation mass (Mr) compared to 1/12 the mass of a 12C atom. Empirical formula Formula showing the simplest whole- Calculating relative formula mass (e.g. H2O) : (n) number ratio of the atoms of each element 1. Write down Ar values of elements in the compound (this in a compound. Pure substance Consisting of just one type of element or is the larger of the two numbers next to (n) compound. An elements symbol): H = 1.0, O = 16.0 Filtrate (n) Liquid that passes through the filter during filtration. 2. Work out the number of atoms of each element: • Filtration separates any insoluble substances Residue (n) Insoluble material left in the filter paper H = 2, O = 1 from a liquid/solvent. during filtration. 3. Multiply the number of each atom by its Ar value and • Crystallisation separates a solute from a Saturated A solution containing the maximum mass of add these together: Mr = (2 x 1.0) + (1 x 16.0) = 18.0 solution. solution (n) solute possible at a given temperature. Liebig condenser Apparatus that can cool and condense a Simple and Fractional distillation (n) substance. Calculating an empirical formula (e.g.
    [Show full text]
  • Building a Still at Low Cost Riku
    Building a still at low cost Riku Building a still at low cost Practical guide for building gadgets + few new ideas. Version 0.7-02.02.2005 By Riku – [email protected] v0.7-02.02.2005 web download 1 Building a still at low cost Riku Introduction....................................................................................................................................3 A still..............................................................................................................................................4 How to make a cheap boiler............................................................................................................5 Pot still heads/condensers................................................................................................................9 Water-cooled:..............................................................................................................................9 Air-cooled:................................................................................................................................12 Reflux stills...................................................................................................................................14 Columns....................................................................................................................................14 Size of a column – size does matter...........................................................................................14 Packing.....................................................................................................................................15
    [Show full text]
  • A Handbook of Chemical Manipulation
    Universitäts- und Landesbibliothek Tirol A handbook of chemical manipulation Williams, Charles Greville London, 1857 Contents urn:nbn:at:at-ubi:2-3808 vii CONTENTS . Section I . Gas-furnace page 28 Gas sand-bath 29 Experimental Laboratory page l Bunsen’s burner 29 Oil- and spirit-lamps . 30 Section II . Circular spirit-lamps . 31 Stoneware wick-holders . 31 Furnaces . Berzelius’s lamp 32 Athanor 10 Crucible jacket 32 Brande’s Table-furnace . 11 Furnace -rings 11 Section IV . Supports for furnace-bars 12 Hood of furnace 12 Blowpipe Apparatus . Sand-pots 13 Combustion-furnace for tube Black’s blowpipe 33 operations 14 Wollaston’s ditto 34 Luhme’s furnace 15 Cronstedt’s ditto 34 Sefstrom’s blast-furnace . 16 Blowpipe-lamp 34 Staffordshire coke as fuel 17 Continuous blast kept up . 36 Platinum crucibles protected . 18 Oxidizing and reducing flame . 36 Precautions with blast-furnace . 18 Supports for substances before Wind -furnace for various opera¬ the blowpipe 37 tions 19 Platinum wire and spoons . 38 Furnace -bars for wind-furnace . 19 Handle for ditto 39 Fused products, precautions in Removal of fused mass from wire making 20 and spoons 39 Chauffer (sheet-iron) . 21 Platinum foil 40 Cupelling furnace 22 Clay supports 40 Muffle 23 Forceps 41 Cupel mould 23 Self-acting blowpipes . 41 Maximum heat, position of, in Table blowpipes 43 furnaces 24 Large sand-bath 24 Section Y . Section III . Baths. Lamps. Spirit-bath 45 Argand gas-burner . 25 Water - and oil-baths . 46 Mixed air and gas-lamp . 26 Table of boiling-points of satu¬ Remington's burner .
    [Show full text]
  • Patented May 31, 1887
    (No Model.) 4. Sheets-Sheet 1. A. M. COYLE. METHOD OF AND APPARATUS FOR DISTILLING WATER. No. 364,199, Patented May 31, 1887. N. Peters, Photo-Lithographer, washington, D. c. (No Model.) 4. Sheets-Sheet 2. A. M. COYLE. METHOD OF AND APPARATUS FOR DISTILLING WATER, No. 364,199. Patented May 31, 1887. t g 4. I A. W T N E S S E S T NVENTO O6. a stattorn 44.7 6. N. PETERs, Photo-Lithographer, Washington, D.C. (No Model.) 4. Sheets-Sheet 3. A., M. COYLE. METHOD OF AND APPARATUS FOR DISTILLING WATER, No. 364,199, Patented May 31, 1887, 7374 928) it losses -4. 2/ 62" ZZ %. 27. 44-4- 33 4a &letotic - M. PETERS. Photo-linographer. Washington, D.C. (No Model.) 4. Sheets-Sheet 4. A. M. COYLE, METHOD OF AND APPARATUS FOR DISTILLING WATER, No. 364,199, Patented May 31, 1887. o W------ tri------------ ...i.4.--------- --W 928i-tv coco 3-1-uovkov Z4.7%M S3 a &lt-totic(ázar ace), N. PETERS, Photo-Lithographer, Washington, d. c. UNITED STATES PATENT OFFICE. ANDREW M. COY LE, OF WASHINGTON, DISTRICT OF COLUMBIA. METHOD OF AN APPARATUS FOR DISTING WATER. SPECIFICATION forming part of letters Patelet No. 354,199, dated May 31, 1887. 8 Application fied Decemb, r 7, 1 SSG. Serial No. 220,941. (No model.) To aid twil O7, it inct? concert. discharge pie is connected with the jacket Beit known that I, ANDREW M. Coy LE, of and carried up outside of the condenser and Washington, in the District of Columbia, have retort to the proper height to maintain the 55 invented certain new and useful Improvements desired water-level in the jacket, and also in in the Method of and Apparatus for Distilling the letort or distilling-drum, as is presently Water and other Fluids, of which the follow described.
    [Show full text]
  • XX'c7rii.-Researches on the Action of the Copper-Zinc
    View Article Online / Journal Homepage / Table of Contents for this issue 678 GLADSTONE AND TRIBE’S RESEARCHES ON THE Published on 01 January 1873. Downloaded by Christian Albrechts Universitat zu Kiel 23/10/2014 03:48:39. XX’C7rII.-Researches on the Action of the copper-zinc Couple on Oryank Bodies. Part 11. On the Iodides of Amy1 and Methyl. By J. H. GLADSTONE,PhD.,F.R.S., and ALFREDTRIBE, F.C.S. FRANKLANDfound that “ iodide of amyl is acted upon by zinc with much more difficulty than the corresponding ethyl compound ;”* he speaks of the necessity of “ a very nice management of the tempera- * Chem. SOC. J., iii, 31. View Article Online ACTION OF THE COPPER-ZINC COUPLE ON ORGANIC BODIES. 679 ture," and though he mentions zinc-amyl among the results of the reaction, he never obtained it in any quantity by this method. For the decomposition of iodide of amyl he resorted to the use of zinc-amalgam in powder in sealed tubes at a temperature a little above that of the boiling-point of the liquid. He thus obtained, not zinc-amyl but a mixture of three hydrocarbons, viz., amyl, CloH,,, a light liquid boiling at 155" ; hydride of amyl, C5H12,an exceedingly mobile liquid with an agreeable odour, boiling at 30" ; amylene, C,H,,, another limpid liquid boiling at 35", and combining with fuming sulphuric acid. It appeared to us therefore a point of special interest to ascertain whether our copper-zinc couple was capable of effecting the decompo- sition of amyl iodide with production of an organo-metallic body.
    [Show full text]
  • Starfish Brochure
    StarFish V4_Layout 1 29/08/2014 09:24 Page 1 Improving the productivity of your chemistry StarFish™ The space saver Multi-experiment work station to improve the productivity of your chemistry 260˚C www.radleys.com StarFish V4_Layout 1 25/03/2014 12:45 Page 2 StarFish - the multi-experiment work station Improve the productivity of your chemistry Gas/Vacuum Manifold • Even distribution to up to five positions or vessels What are the benefits? • Quick-release connectors • Leak-proof shut-off valves • Space saving - uses less space than multiple heating and stirring set-ups. • Increases productivity - multiple positions allow you to heat, stir and reflux Central Support Rod experiments in parallel. • Single or two piece options Screws into base plate • Cost effective - use your • Stainless steel existing stirring hotplate and • glassware. Eliminate the cost of multiple set-ups. • Safer, cleaner working. Eliminate oil baths, reduce spills, mess and accidents. Universal 3 or 5-Way Telescopic Clamps • Flexible - use as many • Adjusts to hold a wide positions as you want. variety of glassware • Velcro or rubber straps • Easy to use and quick to assemble. • Compact - store spare components in a drawer and not on the bench. Water Manifold • Distributes water to up to five condensers simultaneously • Quick-release connectors • Leak-proof shut-off valves 500ml MonoBlock and Clamp • Accepts 3 x 500ml flasks • Universal 3-way telescopic clamp MonoBlocks or PolyBlock • Wide choice of block options • From vials to 500ml flasks Use your own Choice of Base Plates hotplate and glassware • Compatible with all popular • For round or square hotplates brands of stirring hotplate • Optional handles 2 Radleys Shire Hill, Saffron Walden, Essex, CB11 3AZ, United Kingdom.
    [Show full text]
  • Learning Lab Apps (Pty) Ltd
    WorksheetCloud.com - Memorandum 1 Subject: Grade 7 Natural Sciences Topic: Methods of physical separation Total: 34 Marks 1. salt 3 marks Explanation: Salt is dissolved in the water. When the water turns into a gas, the salt remains behind in the flask. 2. Liebig condenser | Liebig condensor | condensor | condenser 3 marks Explanation: The Liebig condenser has a straight inner tube that the warm condensing vapour passes through. The outer tube has cooling water passing through it. In this way the warm vapour cools down and condenses back into a liquid. 3. B: distillation 4 marks Explanation: Distillation is a method used to separate a mixture of a dissolved solid (eg. salt) and a liquid (eg. water). When the mixture is heated (no 15 in diagram), the liquid turns into a gas, is cooled down by the Liebig condenser (no 5 in diagram) and turned into liquid water, which is collected into a separate container (no 8 in diagram). 4. A: distillate 4 marks Explanation: The water which is collected in the beaker during distillation is called the distillate. The distillate is pure water. 5. sieves | a sieve 3 marks Explanation: Sieves were used to separate the two solid substances. The sand fell through and the gold ore remained behind. 6. physical 3 marks Explanation: A mixture is made up of two or more materials with different physical properties, like sand and water. Because they have different properties, they can be separated from one another. Get more content at www.worksheetcloud.com Page 1 of 2 Copyright Learning Lab Apps (Pty) Ltd.
    [Show full text]