Tia/Eia Standard
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
The Twisted-Pair Telephone Transmission Line
High Frequency Design From November 2002 High Frequency Electronics Copyright © 2002, Summit Technical Media, LLC TRANSMISSION LINES The Twisted-Pair Telephone Transmission Line By Richard LAO Sumida America Technologies elephone line is a This article reviews the prin- balanced twisted- ciples of operation and Tpair transmission measurement methods for line, and like any electro- twisted pair (balanced) magnetic transmission transmission lines common- line, its characteristic ly used for xDSL and ether- impedance Z0 can be cal- net computer networking culated from manufactur- ers’ data and measured on an instrument such as the Agilent 4395A (formerly Hewlett-Packard HP4395A) net- Figure 1. Lumped element model of a trans- work analyzer. For lowest bit-error-rate mission line. (BER), central office and customer premise equipment should have analog front-end cir- cuitry that matches the telephone line • Category 3: BWMAX <16 MHz. Intended for impedance. This article contains a brief math- older networks and telephone systems in ematical derivation and and a computer pro- which performance over frequency is not gram to generate a graph of characteristic especially important. Used for voice, digital impedance as a function of frequency. voice, older ethernet 10Base-T and commer- Twisted-pair line for telephone and LAN cial customer premise wiring. The market applications is typically fashioned from #24 currently favors CAT5 installations instead. AWG or #26 AWG stranded copper wire and • Category 4: BWMAX <20 MHz. Not much will be in one of several “categories.” The used. Similar to CAT5 with only one-fifth Electronic Industries Association (EIA) and the bandwidth. the Telecommunications Industry Association • Category 5: BWMAX <100 MHz. -
1) What Is the Name of an Ethernet Cable That Contains Two
1) What is the name of an Ethernet cable that contains two electrical conductors ? A coaxial cable 2) What are the names of the two common conditions that degrade the signals on c opper-based cables? Crosstal and attenuation 3) Which topology requires the use of terminators? Bus 4) Which of the following topologies is implemented only logically, not physical ly? Ring 5) How many wire pairs are actually used on a typical UTP Ethernet network? Two 6) What is the name of the process of building a frame around network layer info rmation? Data encapsulation 7) Which of the connectors on a network interface adapter transmits data in para llel? The System bus connector 8) Which two of the following hardware resources do network interface adapters a lways require? I/O port address and IRQ 9) What is the name of the process by which a network interface adapter determin es when it should transmit its data over the network? Media Access Control 10) Which bus type is preferred for a NIC that will be connected to a Fast Ether net network? PCI 11) A passive hub does not do which of the following? Transmit management information using SNMP 12) To connect two Ethernet hubs together, you must do which of the following? Connect the uplink port in one hub to a standard port on the other 13) Which term describes a port in a Token Ring MAU that is not part of the ring ? Intelligent 14) A hub that functions as a repeater inhibits the effect of____________? Attenuation 15) You can use which of the following to connect two Ethernet computers togethe r using UTP -
Gigabit Ethernet - CH 3 - Ethernet, Fast Ethernet, and Gigabit Ethern
Switched, Fast, and Gigabit Ethernet - CH 3 - Ethernet, Fast Ethernet, and Gigabit Ethern.. Page 1 of 36 [Figures are not included in this sample chapter] Switched, Fast, and Gigabit Ethernet - 3 - Ethernet, Fast Ethernet, and Gigabit Ethernet Standards This chapter discusses the theory and standards of the three versions of Ethernet around today: regular 10Mbps Ethernet, 100Mbps Fast Ethernet, and 1000Mbps Gigabit Ethernet. The goal of this chapter is to educate you as a LAN manager or IT professional about essential differences between shared 10Mbps Ethernet and these newer technologies. This chapter focuses on aspects of Fast Ethernet and Gigabit Ethernet that are relevant to you and doesn’t get into too much technical detail. Read this chapter and the following two (Chapter 4, "Layer 2 Ethernet Switching," and Chapter 5, "VLANs and Layer 3 Switching") together. This chapter focuses on the different Ethernet MAC and PHY standards, as well as repeaters, also known as hubs. Chapter 4 examines Ethernet bridging, also known as Layer 2 switching. Chapter 5 discusses VLANs, some basics of routing, and Layer 3 switching. These three chapters serve as a precursor to the second half of this book, namely the hands-on implementation in Chapters 8 through 12. After you understand the key differences between yesterday’s shared Ethernet and today’s Switched, Fast, and Gigabit Ethernet, evaluating products and building a network with these products should be relatively straightforward. The chapter is split into seven sections: l "Ethernet and the OSI Reference Model" discusses the OSI Reference Model and how Ethernet relates to the physical (PHY) and Media Access Control (MAC) layers of the OSI model. -
Catv Cabling System
NYULMC AMBULATORY CARE CENTER – FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: 032698.000 Issued for GMP March 15, 2017 SECTION 27 41 33 CATV CABLING PART 1 - GENERAL 1.1 SYSTEM DESCRIPTION A. Furnish and install a complete and fully operational Television Signal Distribution System capable of delivering up to 158 video channels (6 MHz NTSC Channels containing NTSC, ATSC and QAM modulated programs) and IP Video over an installed Category 6A unshielded twisted pair cable system. The System shall utilize a cable plant comprised of a TIA/EIA 568 compliant horizontal distribution cable system and a coaxial and/or single mode fiber backbone system. The System shall employ Active Automatic Gain Control Electronics to adjust the video signal levels to each TV and shall be capable of supporting up to 14,000 connected devices. The System shall support bi-directional RF transmission for backbone interconnections. Include amplifiers, power supplies, cables, outlets, attenuators, hubs, baluns, adaptors, transceivers, and other parts necessary for the reception and distribution of the local CATV signals. Back-feed existing campus system. (CAT 5e is acceptable to 117 channels) B. Distribute cable channels to TV outlets to permit simple connection of EIA standard Analog/Digital television receivers. C. Deliver at outlets monochrome and NTSC color television signals without introducing noticeable effect on picture and color fidelity or sound. Signal levels and performance shall meet or exceed the minimums specified in Part 76 of the FCC Rules and Regulations D. Provide reception quality at each outlet equal to or better than that received in the area with individual antennas. -
HD Television on Cat 5/6 Cable Cable TV on Cat 5/6 Cable
HD Television on Cat 5/6 Cable Cable TV on Cat 5/6 Cable Innovative Technology .... Exceptional Quality! The Lynx® Television Network Distributes up to 640 digital Increases flexibility for moves, adds channels on Cat 5 or Cat 6 cable and changes Excellent for cable TV, SMATV, or Improves reliability off-air television distribution Creates a technology bridge to Simplifies cabling requirements Internet TV and IPTV The Lynx Television Network simultaneously simplifies installation, standardizes the wiring, delivers up to 210 HDTV channels, 640 and reduces maintenance requirements. standard digital channels, or 134 analog channels on Cat 5 or Cat 6 cable. Frequency The Lynx Network increases system flexibility capabilities are 5 MHz to 860 MHz. because moves, adds, and changes are easy with Cat5/6 cable. A Lynx hub in the wiring closet converts an unbalanced coaxial signal into eight or A homerun wiring design improves reliability sixteen balanced signals transmitted on because there are no taps or splitters between twisted pair cables. At the point of use a the distribution hub and the TV. wallplate F or single port converter changes the signal back to coaxial form. The Lynx Network also provides a “technology bridge” to Internet TV and IPTV by setting up the cabling that these technologies use. A patented RF balun is the centerpiece of the Lynx design. A pair of send / receive baluns delivers a clean RF signal to each TV (on pair four). The baluns use an RF technology that delivers HD, digital, and analog channels on network cables without using any bandwidth Wallplate F Single port converter on the network itself. -
Introduction to Digital Subscriber's Line (DSL) Chapter 2 Telephone
Introduction to Digital Subscriber’s Line (DSL) Professor Fu Li, Ph.D., P.E. © Chapter 2 Telephone Infrastructure · Telephone line dates back to Bell in 1875 · Digital Transmission technology using complex algorithm based on DSP and VLSI to compensate impairments common to phone lines. · Phone line carries the single voice signal with 3.4 KHz bandwidth, DSL conveys 100 Compressed voice signals or a video signals. 1 · 15% phones require upgrade activities. · Phone company spent approximately 1 trillion US dollars to construct lines; · 700 millions are in service in 1997, 900 millions by 2001. · Most lines will support 1 Mb/s for DSL and many will support well above 1Mb/s data rate. Typical Voice Network 2 THE ACCESS NETWORK • DSL is really an access technology, and the associated DSL equipment is deployed in the local access network. • The access network consists of the local loops and associated equipment that connects the service user location to the central office. • This network typically consists of cable bundles carrying thousands of twisted-wire pairs to feeder distribution interfaces (FDIs). Two primary ways traditionally to deal with long loops: • 1.Use loading coils to modify the electrical characteristics of the local loop, allowing better quality voice-frequency transmission over extended distances (typically greater than 18,000 feet). • Loading coils are not compatible with the higher frequency attributes of DSL transmissions and they must be removed before DSL-based services can be provisioned. 3 Two primary ways traditionally to deal with long loops • 2. Set up remote terminals where the signals could be terminated at an intermediate point, aggregated and backhauled to the central office. -
Retrospective on Development of Radio and Wire Data Communication
March, 2006 IEEE P802.15-06-0107-00-wng0 IEEE P802.15 Wireless Next Generation Networks Project IEEE P802.15 Working Group for Wireless Personal Area Networks (WPANs) Title Retrospective on Development of Radio and Wire Data Communication Date 4 March 2006 Submitted Source Chandos A. Rypinski Voice: +1.415.435.0642 consultant Fax: [- ] Tiburon, CA 94920 USA E-mail: [email protected] Re: Call for contributions for 15WNG Erik Schylander, 13 Feb 2006 Abstract An account of: the development of phase shift keying and orthogonal frequency division multiplex with carriers positioned at spectral null of the adjacent carrier at Collins Radio 1954-58, the early development of 802.3 CSMA, 802.4 Token bus and 802.5 Token ring and the 802.4L radio PHY for token bus, the 802.6 and 802.9 committee’s working on voice-data integration, the start of 802.11 from 802.4L, the original functional targets and the DFW MAC adopted as a starting point the circumstances for the development 11A and 11B. Purpose The intent is show the effect of early and current decision-making as influenced by function goals and obscure design considerations. Possibly some future choices may be better made with knowledge of these examples. Notice This document has been prepared to assist the IEEE P802.15. It is offered as a basis for discussion and is not binding on the contributing individual(s) or organization(s). The material in this document is subject to change in form and content after further study. The contributor(s) reserve(s) the right to add, amend or withdraw material contained herein. -
Digital Subscriber Lines and Cable Modems Digital Subscriber Lines and Cable Modems
Digital Subscriber Lines and Cable Modems Digital Subscriber Lines and Cable Modems Paul Sabatino, [email protected] This paper details the impact of new advances in residential broadband networking, including ADSL, HDSL, VDSL, RADSL, cable modems. History as well as future trends of these technologies are also addressed. OtherReports on Recent Advances in Networking Back to Raj Jain's Home Page Table of Contents ● 1. Introduction ● 2. DSL Technologies ❍ 2.1 ADSL ■ 2.1.1 Competing Standards ■ 2.1.2 Trends ❍ 2.2 HDSL ❍ 2.3 SDSL ❍ 2.4 VDSL ❍ 2.5 RADSL ❍ 2.6 DSL Comparison Chart ● 3. Cable Modems ❍ 3.1 IEEE 802.14 ❍ 3.2 Model of Operation ● 4. Future Trends ❍ 4.1 Current Trials ● 5. Summary ● 6. Glossary ● 7. References http://www.cis.ohio-state.edu/~jain/cis788-97/rbb/index.htm (1 of 14) [2/7/2000 10:59:54 AM] Digital Subscriber Lines and Cable Modems 1. Introduction The widespread use of the Internet and especially the World Wide Web have opened up a need for high bandwidth network services that can be brought directly to subscriber's homes. These services would provide the needed bandwidth to surf the web at lightning fast speeds and allow new technologies such as video conferencing and video on demand. Currently, Digital Subscriber Line (DSL) and Cable modem technologies look to be the most cost effective and practical methods of delivering broadband network services to the masses. <-- Back to Table of Contents 2. DSL Technologies Digital Subscriber Line A Digital Subscriber Line makes use of the current copper infrastructure to supply broadband services. -
Ethernet/Category 5 Network Cabling Guide Prepared by SJ Wilkinson (August 2002) Based on Steve Derose’S Guide to CAT5 Network Wiring (See Later Web Reference)
Ethernet/Category 5 Network Cabling Guide Prepared by SJ Wilkinson (August 2002) Based on Steve DeRose’s Guide to CAT5 Network Wiring (See later Web Reference) Networks A Local Area Network (LAN) can be as simple as two computers, each having a network interface card (NIC) or network adapter and running network software, connected together with a crossover cable. Here the crossover cable would have a plug at either end to connect into the NIC socket at the back of each computer. The next step up would be a network consisting of three or more computers and a hub. Each of the computers is plugged into the hub with a straight-thru cable (the crossover function is performed by the hub). For a small network the straight-thru cables would have plugs at either end – one to connect to the computer and one to the hub. For larger networks wall cabling, wall sockets and patch cables are used. A CAT5 "patch panel" is used at the hub end where all your wires come together and provides a group of sockets for further cables. Straight-thru patch cables connect computers to sockets (jacks). Straight-thru wall cables connect sockets to the patch panel. Straight-thru patch cables connect the patch panel to the hub. Patch panels often make network cabling neater but are not essential as (a) wiring a plug is no harder than wiring a panel; (b) you still need cables to go from the panel to the hub; and (c) it adds extra connections, so lowers reliability. 1 Planning your Network Pick a location for your hub, preferably centred to keep cable runs shorter. -
Dodea FACILITIES MANAGEMENT GUIDE
DoDEA FACILITIES MANAGEMENT GUIDE: TECHNOLOGY SYSTEMS DESIGN GUIDELINES DoDEA-NETWORK VERSION 2.0 DEPARTMENT OF DEFENSE EDUCATION ACTIVITY APRIL 14, 2016 UPDATED DRAFT DoDEA Technology Systems Design Guide – DoDEA Network Requirements TABLE OF CONTENTS Acronyms ........................................................................................................................................ 3 1.0 Purpose ........................................................................................................................ 5 2.0 Applicability ................................................................................................................. 5 3.0 References ................................................................................................................... 5 4.0 Responsibilities ............................................................................................................ 7 5.0 Data/Telecommunications Systems Summary ............................................................. 8 5.1 Outside Cable Plant .................................................................................................... 10 5.2 System Requirements ................................................................................................ 11 5.2.A Main Telecommunications Room (TR1) ........................................................................... 11 5.2.B Secondary Telecommunications Room (TR2) ................................................................... 13 5.2.C Video Distribution ............................................................................................................ -
Datacomm Products and Equipment Catalog
DataComm Products and Equipment Catalog IDEAL DataComm 112060_DataComm08_COVER.indd2060_DataComm08_COVER.indd 2 11/8/08/8/08 99:41:29:41:29 AAMM The way every job should be IDEAL DataComm is dedicated to helping low voltage/datacomm professionals keep networks up and running. The system of products we have thoughtfully crafted ensures the highest-quality terminations with the ease-of-use you would expect from IDEAL. Our DataComm line includes a system solution for paired conductor, coax and fiber optic cabling. www.idealindustries.com Paired Conductor Products Wire Cutters . A-2 A Wire Strippers . .A-2 Crimp Tools . A-4 Punch Down Tools . A-5 Tool and Connector Kits . A-5 Wall Plates . A-9 Cables . .A-10 Connectors . A-10 Coaxial Termination Products Tool Selection Chart . B-2 B Wire Cutters . B-3 Wire Strippers . B-3 Crimp Tools . B-4 Compression Tools . .B-6 Connectors . B-7 Splitters . .B-8 Wall Plates . B-8 Tool and Connector Kits . B-9 BNC Coaxial Connectors . .B-12 Fiber Optic Products Wire Strippers . C-2 C Fiber Optic Accessories . C-3 Table of Contents Table Test Equipment Qualification Testers . .D-2 D Certification Testers . D-4 Hand-Held Testers . D-7 Related Products Resources . E-1 E Multi Media Installation Guide . .E-3 Technical Information . .E-12 Residential Coax Application Guide . .E-13 Index Alphabetical Index . F-1 F Catalog Number Index . F-3 For applicable GSA Contracts — contact IDEAL at 800-947-3614 New Products Mini Coax Stripper Grounding Block Q Adjustable stripper for Q Solid zinc alloy, mini coax cable nickel plated and Page B-3 chromate finished Page B-8 OmniSeal™ Pro Compression Tools Q Compression tools now offer additional features and increased connector Compression Connector compatibility Installation Kit Page B-6 Q Three tools in one handy pouch that clips easily to your belt. -
Lan.Wiring.Jim.Trulove.Pdf
LAN Wiring This page intentionally left blank LAN Wiring Third Edition James Trulove McGraw-Hill New York Chicago San Francisco Lisbon London Madrid Mexico City Milan New Delhi San Juan Seoul Singapore Sydney Toronto Copyright © 2006 by James Trulove. All rights reserved. Manufactured in the United States of America. Except as permit- ted under the United States Copyright Act of 1976, no part of this publication may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without the prior written permission of the publisher. 0-07-148345-4 The material in this eBook also appears in the print version of this title: 0-07-145975-8. All trademarks are trademarks of their respective owners. Rather than put a trademark symbol after every occurrence of a trademarked name, we use names in an editorial fashion only, and to the benefit of the trademark owner, with no intention of infringement of the trademark. Where such designations appear in this book, they have been printed with initial caps. McGraw-Hill eBooks are available at special quantity discounts to use as premiums and sales promotions, or for use incor- porate training programs. For more information, please contact George Hoare, Special Sales, at george_hoare@mcgraw- hill.com or (212) 904-4069. TERMS OF USE This is a copyrighted work and The McGraw-Hill Companies, Inc. (“McGraw-Hill”) and its licensors reserve all rights in and to the work. Use of this work is subject to these terms. Except as permitted under the Copyright Act of 1976 and the right to store and retrieve one copy of the work, you may not decompile, disassemble, reverse engineer, reproduce, modify, create derivative works based upon, transmit, distribute, disseminate, sell, publish or sublicense the work or any part of it without McGraw-Hill’s prior consent.