FREQUENCY AND TIME ERROR MONITORING – 2ND

QUARTER 2014

FOR THE NATIONAL ELECTRICITY MARKET

Published: DECEMBER 2014

FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

IMPORTANT NOTICE

Purpose AEMO has prepared this document to provide information about the frequency and time error performance in the National Electricity Market Mainland and regions for the period April to June 2014.

Disclaimer This document or the information in it may be subsequently updated or amended. This document does not constitute legal or business advice, and should not be relied on as a substitute for obtaining detailed advice about the National Electricity Law, the National Electricity Rules, or any other applicable laws, procedures or policies. AEMO has made every effort to ensure the quality of the information in this document but cannot guarantee its accuracy or completeness.

Accordingly, to the maximum extent permitted by law, AEMO and its officers, employees and consultants involved in the preparation of this document:

 make no representation or warranty, express or implied, as to the currency, accuracy, reliability or completeness of the information in this document; and  are not liable (whether by reason of negligence or otherwise) for any statements or representations in this document, or any omissions from it, or for any use or reliance on the information in it.

© 2014. The material in this publication may be used in accordance with the copyright permissions on AEMO’s website. Australian Energy Market Operator Ltd ABN 94 072 010 327 www.aemo.com.au [email protected] NEW SOUTH WALES QUEENSLAND SOUTH AUSTRALIA VICTORIA AUSTRALIAN CAPITAL TERRITORY TASMANIA FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

CONTENTS

1. INTRODUCTION 4

2. OPERATION WITHIN THE NORMAL OPERATING FREQUENCY BAND 5

3. EVENTS OUTSIDE THE NORMAL OPERATING FREQUENCY EXCURSION BAND 6

4. EVENTS THAT DID NOT COMPLY WITH THE FREQUENCY OPERATING STANDARDS 7 4.1 Events in the Mainland region 7 4.2 Events in the Tasmania region 7

5. ACCUMULATED TIME ERROR 13

© AEMO 2014 3 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

1. INTRODUCTION AEMO must use reasonable endeavours to maintain power system frequency and time error within the limits specified by the Reliability Panel in the Frequency Operating Standards1 for the Mainland and Tasmania region. This document reports on the frequency and time error performance observed during April, May and June 2014 in all regions of the National Electricity Market (NEM). Queensland, New South Wales, Victoria and South Australia are referred to as the Mainland region throughout the report.

The Power System Frequency and Time Deviation Monitoring Report – Reference Guide2 outlines the calculation procedure used by AEMO to produce the quarterly Frequency and Time Error Monitoring report.

The analysis of the delivery of Slow Raise, Slow Lower, Delayed Raise and Delayed Lower Frequency Controlled Ancillary Services (FCAS) presented in this report are based on 4-second data. Unless otherwise noted, frequency data for Mainland regions is sourced from 4-second measurements in New South Wales and frequency data for Tasmania region is sourced from 4-second measurements in Tasmania. The analysis of Fast Raise and Fast Lower ancillary services delivered is based on high-speed (50 millisecond sampling or less) data from Market Participants and is only presented in this report for events where the appropriate data is available.

1 http://aemc.gov.au/Australia-s-Energy-Market/Market-Legislation/Electricity-Guidelines-and-Standards 2 http://aemo.com.au/Electricity/Resources/Reports-and-Documents/Frequency-and-Time-Error-Monitoring

© AEMO 2014 4 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

2. OPERATION WITHIN THE NORMAL OPERATING FREQUENCY BAND The Mainland and Tasmanian frequency remained within the Normal Operating Frequency Band (49.85 Hz – 50.15 Hz) more than 99% of the time over this reporting period, as required by the Frequency Operating Standards.

All Mainland and Tasmania events within the Normal Operating Frequency Excursion Band (49.75 Hz – 50.25 Hz) returned to the Normal Operating Frequency Band within the time limits specified in the Frequency Operating Standards.

The percentage time of operation within the Normal Operating Frequency Band over the last 12 months is shown in Figure 1.

Figure 1 Percentage time within the Normal Operating Frequency Band

© AEMO 2014 5 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

3. EVENTS OUTSIDE THE NORMAL OPERATING FREQUENCY EXCURSION BAND Table 1 and Table 2 summarise the events in the Mainland and Tasmania regions with frequency excursions outside the Normal Operating Frequency Excursion Band.

All Mainland and Tasmania events in Table 1 complied with the Frequency Operating Standards by returning to the Normal Operating Frequency Band within the specified times. Events in Table 2 didn’t comply with the Frequency Operating Standards. These events are discussed further in Section 4.

Table 1 Events in the Mainland and Tasmania regions with frequency excursions outside the Normal Operating Frequency Excursion Band but complied with the Frequency Operating Standards Number of Events Event Low/High Frequency Event Mainland Tasmania

LOW 0 43 Load Event HIGH 0 103

LOW 1 3 Generation Event HIGH 0 2

LOW 0 0 Network Event HIGH 0 4

LOW 0 0 Separation Event HIGH 0 0

LOW 2 2 Multiple Contingency Event HIGH 0 0

Table 2 Events in the Mainland and Tasmania regions that didn’t comply with the Frequency Operating Standards Number of Events Event Low/High Frequency Event Mainland Tasmania

LOW 0 3 Normal event/No contingency or load event HIGH 0 33

3 One normal event in Tasmania on 14/05/2014 resulted in both a high and low frequency excursion outside the Normal Operating Frequency Excursion Band

© AEMO 2014 6 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

4. EVENTS THAT DID NOT COMPLY WITH THE FREQUENCY OPERATING STANDARDS This section analyses events identified as not complying with the Frequency Operating Standards. 4.1 Events in the Mainland region There were no frequency events recorded in the Mainland region that did not comply with the Mainland Frequency Operating Standard during this reporting period. 4.2 Events in the Tasmania region There were five frequency events recorded in the Tasmania region that did not comply with the Tasmania Frequency Operating Standard during this reporting period. These events are listed in Table 3.

Table 3 Frequency events in the Tasmania region that did not comply with the Frequency Operating Standards

Time outside Normal Operating Date Event Min/Max Frequency (Hz) Frequency Band (48.15 Hz – 50.15 Hz) (sec)

No contingency causing the 0816 hrs 15/04/2014 49.67 12 event could be identified

No contingency causing the 1303 hrs 13/05/2014 50.28 36 event could be identified

No contingency causing the 49.73 1001 hrs 14/05/2014 132 event could be identified 50.25

No contingency causing the 1707 hrs 14/05/2014 49.69 280 event could be identified

No contingency causing the 0927 hrs 26/06/2014 50.26 96 event could be identified

4.2.1 Low frequency event: 0816 hrs 15/04/2014  No contingency could be identified as the cause of this event  The frequency excursion reached a minimum of 49.67 Hz during the event, remaining outside the Normal Operating Frequency Band for 12 seconds. This event is shown in Figure 2  Gordon rapidly decreased its output by 12 MW, not following its dispatch target, which contributed to the low frequency excursion  reduced export to the mainland by 12 MW to return the frequency to the Normal Operating Frequency Band  The performance of Fast Raise services was not evaluated as high speed measurements are not available  The frequency excursion was not of sufficient duration to evaluate the performance of Slow Raise or Delayed Raise Frequency Controlled Ancillary Services (FCAS)

© AEMO 2014 7 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

Figure 2 Low Frequency event that occurred in Tasmania at 0816 hrs on 15/04/2014

Tasmania Tasmania (Hz) 49.85Hz 50.15Hz 50.3

50.2

50.1

50

49.9

49.8

49.7

49.6

08:16 08:17 08:18 08:19 08:20 08:21 08:22 08:23 08:24 08:25 08:26 08:27 08:28 08:29 08:30 08:31 08:32 08:33 08:34 08:35 08:36

4.2.2 High frequency event: 1303 hrs 13/05/2014  No contingency could be identified as the cause of this event  The Tasmania frequency reached a maximum of 50.28 Hz during the event, remaining outside the Normal Operating Frequency Band for 36 seconds. This event is shown in Figure 3  increased its output 30 MW over its dispatch target which contributed to the high frequency excursion  Basslink was out of service for maintenance during the event and was therefore unable to assist in controlling the Tasmania frequency  The performance of Fast Lower services was not evaluated as high speed measurements are not available  The frequency excursion was not of sufficient duration to evaluate the performance of Slow Lower or Delayed Lower FCAS

© AEMO 2014 8 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

Figure 3 High frequency event that occurred in Tasmania at 1303 hrs on 13/05/2014

Tasmania Tasmania (Hz) 49.85Hz 50.15Hz 50.4

50.3

50.2

50.1

50

49.9

49.8

49.7

13:02 13:03 13:04 13:05 13:06 13:07 13:08 13:09 13:10 13:11 13:12 13:13 13:14 13:15 13:16 13:17 13:18 13:19 13:20 13:21 13:22

4.2.3 High and Low frequency event: 1001 hrs 14/05/2014  No contingency could be identified as the cause of this event  The Tasmania frequency reached a maximum of 50.25 Hz and a minimum of 49.73 Hz during the event, remaining outside the Normal Operating Frequency Band for 132 seconds. This event is shown in Figure 4  Poatina Unit 2 increased its output by 80 MW, following its dispatch target, which contributed to the high frequency excursion  Tasmania demand increased instantaneously by 17 MW which contributed to the low frequency excursion  Basslink was out of service for maintenance during the event and was therefore unable to assist in controlling the Tasmania frequency  The performance of Fast Lower and Fast Raise services was not evaluated as high speed measurements are not available  The performance of Slow Lower services was insufficient to assist the stabilisation and recovery of the Tasmania frequency as shown in Figure 5  The frequency excursion was not of sufficient duration to evaluate the performance of Delayed Lower or Delayed Raise FCAS

© AEMO 2014 9 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

Figure 4 High/Low frequency event that occurred in Tasmania at 1001 hrs on 14/05/2014

Tasmania Tasmania (Hz) 49.85Hz 50.15Hz 50.3

50.2

50.1

50

49.9

49.8

49.7

10:11 10:02 10:03 10:04 10:05 10:06 10:07 10:08 10:09 10:10 10:12 10:13 10:14 10:15 10:16 10:17 10:18 10:19 10:20 10:21 10:01

Figure 5 FCAS response during high frequency event that occurred in Tasmania at 1001 hrs on 14/05/2014 Tasmania 250 Enabled FCAS 200

Net Enabled FCAS 150 response

MW Enabled FCAS 100 response assisting frequency recovery Enabled FCAS 50 response hindering frequency recovery 0 L6 L60 L5

4.2.4 Low frequency event: 1707 hrs 14/05/2014  No contingency could be identified as the cause of this event  The Tasmania frequency reached a minimum of 49.69 Hz during the event, remaining outside the Normal Operating Frequency Band for 280 seconds. This event is shown in Figure 6  Tungatinah Power Station remained 60 MW under its dispatch target which contributed to the low frequency excursion

© AEMO 2014 10 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

 Gordon Power Station increased its output, in response to Raise Regulation FCAS, to return the frequency to the Normal Operating Frequency Band  Basslink was out of service for maintenance during the event and was therefore unable to assist in controlling the Tasmania frequency  The performance of Fast Raise services was not evaluated as high speed measurements are not available  The performance of Slow Raise services was insufficient to assist the stabilisation and recovery of the Tasmania frequency as shown in Figure 7  The frequency excursion was not of sufficient duration to evaluate the performance of Delayed Raise FCAS

Figure 6 Low frequency event that occurred in Tasmania at 1707 hrs on 14/05/2014

Tasmania Tasmania (Hz) 49.85Hz 50.15Hz 50.3

50.2

50.1

50

49.9

49.8

49.7

49.6

17:07 17:08 17:09 17:10 17:11 17:12 17:13 17:14 17:15 17:16 17:17 17:18 17:19 17:20 17:21 17:22 17:23 17:24 17:25 17:26 17:06

Figure 7 FCAS response during low frequency event that occurred in Tasmania at 1707 hrs on 14/05/2014 Tasmania 120 Enabled FCAS 100

80 Net Enabled FCAS response MW 60 Enabled FCAS response assisting 40 frequency recovery Enabled FCAS 20 response hindering frequency recovery 0 R6 R60 R5

© AEMO 2014 11 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

4.2.5 High frequency event: 0927 hrs 26/06/2014  No contingency could be identified as the cause of this event  The Tasmania frequency reached a maximum of 50.26 Hz during the event, remaining outside the Normal Operating Frequency Band for 96 seconds. This event is shown in Figure 8  The performance of Fast Lower services was not evaluated as high speed measurements are not available  The performance of Slow Lower services was insufficient to assist the stabilisation and recovery of the Tasmania frequency as shown in Figure 9  The frequency excursion was not of sufficient duration to evaluate the performance of Delayed Lower FCAS

Figure 8 High frequency event that occurred in Tasmania at 0927 hrs on 26/06/2014

Tasmania (Hz) 49.85Hz Tasmania 50.15Hz 50.3

50.25

50.2

50.15

50.1

50.05

50

49.95

49.9

49.85

49.8

09:27 09:28 09:29 09:30 09:31 09:32 09:33 09:34 09:35 09:36 09:37 09:38 09:39 09:40 09:41 09:42 09:43 09:44 09:45 09:46 09:47

Figure 9 FCAS response during high frequency event that occurred in Tasmania at 0927 hrs on 26/06/2014 Tasmania 180 160 Enabled FCAS 140 120 Net Enabled FCAS 100 response MW 80 Enabled FCAS 60 response assisting 40 frequency recovery 20 Enabled FCAS response hindering 0 frequency recovery -20 L6 L60 L5

© AEMO 2014 12 FREQUENCY AND TIME ERROR MONITORING – 2ND QUARTER 2014

5. ACCUMULATED TIME ERROR The Frequency and Operating Standards require that the accumulated time error be maintained within the range ± 5 seconds in Mainland regions and ± 15 seconds in Tasmania. Constraints used to control Mainland accumulated time error, by varying the amount of Regulation FCAS enabled, are based upon measurements taken in Queensland and New South Wales. The ranges of accumulated time error recorded for measurements in Queensland, New South Wales and Tasmania are provided in Table 4.

Table 4 Maximum and Minimum time error measurements for Queensland, New South Wales and Tasmania

Value Queensland New South Wales Tasmania

Highest positive time error (seconds) 2.43 2.56 12.73

Lowest negative time error (seconds) -4.47 -4.19 -13.77

© AEMO 2014 13