Small Tool Instruments and Data Management

Standard Digital Indicator ABS Digimatic Indicator ID-C

Bulletin No. 1966

Digital indicators offer dramatically improved readability, usability and functionality Digital indicators that offer dramatically improved ease of reading measurement values, usability and functionality ABS Digimatic Indicator ID-C

The Nakatsugawa plant is in the central industrial park of beautiful Nakatsugawa city, in the Gifu prefecture. This plant specializes in manufacturing sensor products and handles the complete development-to-production cycle for measuring instruments such as dial gages, test indicators, Digimatic indicators, and bore gages. It was opened in 1997 as the 12th Mitutoyo plant in . Using its state-of-the-art production techniques and facilities, this plant continues to provide Mitutoyo products that are praised around the world and used with confidence.

Actual Actual Actual size size size

543-392B 543-472B 543-492B

ABS Digimatic indicator ID-C is a standard digital indicator. A large Examples of use LCD incorporating 11mm characters (existing products: 8.5mm) is used to improve visibility, and three large, easy-to-press buttons are used in the design to make operations easier to perform. In addition, this affordable product has various measurement functions, including the ability to perform scaling calculations, judge tolerance, hold data, and perform general comparison measurements.

2 Digital indicators that offer dramatically improved ease of reading measurement values, usability and functionality ABS Digimatic Indicator ID-C

1. Large LCD 4. Functions that support measurement The large LCD incorporates The ID-C has various functions, 11mm characters giving 1.5 including the ability to hold data, times the character area of output data, switch the measuring Measurement value and tolerance judgment existing products (which display 11mm direction, judge tolerance, change 8.5mm characters) making the scale factor, and a lock to prevent measurement values much misoperation. Enlarged display of the tolerance judgment result easier to read. Actual size (For details, see page 6.)

2. Three large buttons 5. 330° rotary display 330° 330° The popular three-large-button design, which is used in products such as the ABS coolant proof Digimatic indicator ID-N/ID-B, makes buttons easier to press and The display can be rotated 330°, operations easier to perform. allowing use at a position where you can easily read the measurement value.

• Power switch • Data output (when connected to an Application products for one-touch quick external device) 6. • Data hold (when no external device is measurement connected) • Parameter setting mode Various application products are available that enable you to perform one-touch Count direction switching, tolerance judgment • Switches between the ABS (preset) and quick measurement of the thickness of small parts, papers, felt, lenses, and setting, resolution switching, scale factor INC (zeroset) measurement modes pipes, as well as the depth of narrow grooves on cylindrical workpieces, groove setting, and function lock setting depth, and steps. ABS measurement mode INC measurement mode (For details, see pages 8-11.) Preset using a reference gage to measure the Zeroset using a reference gage to perform absolute value from a measurement reference a comparison measurement of the difference ABS Digimatic between the reference gage and measured workpiece upright gage

Switches the measurement mode between ABS and INC.

Press and hold the SET button 4.267 ABS Digimatic (for at least two seconds) to 50 mm switch the mode. 50 mm thickness gage reference reference 54.267 54.267

Measured workpiece Measured gage gage workpiece Measured ABS Digimatic Operation in ABS (preset) measurement mode Operation in INC (zeroset) measurement mode depth gage

3. Expanded lifting capability 7. The ABS (ABSOLUTE) sensor The lifting function that moves the spindle up and down has been expanded to The original Mitutoyo ABS (ABSOLUTE) sensor, which is capable of relocating improve work efficiency when using the ID-C mounted on a stand. the origin even after turning the power off, enables you to quickly start multi- For models that have a 12.7mm measuring range, point measurement. Also, the ABS measurement mode can be restored even a lifting lever (special accessory) can be mounted after measurement in the INC mode, where zerosetting on the left or right side, improving work efficiency is possible at any position, improving work efficiency. and smoothness of movement. A lifting cable (special accessory) provides a maximum of approximately 25.4mm of spindle movement (twice 8. that of existing models). So for models that have a Inspection certificate provided as standard 12.7mm or 25.4mm measuring range, the spindle can Mitutoyo provides an inspection certificate that includes inspection data as be moved through the entire measuring range. (Applied standard to guarantee that every product shipped is of high quality and safe to models that have a 50.8mm measuring range, the to use. Upon request, we can also calibrate purchased measuring instruments spindle can be retracted by approximately 25.4mm from and issue a calibration certificate that proves traceability to national (or the extended position.) international) standards for a fee. To minimize calibration uncertainty as much Lifting knob (special accessory) as possible, both the inspection certificate and calibration certificate are issued after measurement using dedicated testers developed with advanced Mitutoyo By using a lifting knob (special accessory) fitted to measurement technologies. Note that the inspection certificate cannot be used the the top of the spindle, you can perform full- to obtain a calibration certificate because the former does not indicate the date stroke operation without directly touching the of purchase.

#%24)&)#!4%¬/&¬).30%#4)/. 検査成績書 #ERTIlCATE¬.O spindle. 0RODUCT¬NAME¬¬$IGIMATIC¬)NDICATOR #ODE¬.O¬¬  -ODEL¬¬)$ #8 3ERIAL¬.O¬¬ 'RADUATION¬¬MM -EASURING¬SPAN¬¬MM 4EMPERATURE¬¬°¬3TANDARD¬4EMPERATURE )NSPECTION¬STANDARD¬¬-ITUTOYO¬STANDARD¬ 1#¬-ANAGER¬¬4+OSUDA -AXIMUM¬0ERMISSIBLE¬ERROR 指示の最大許容差¬-0%¬OF¬INDICATION UNIT¬«M 測定値¬ERROR -0% ¬OF¬INDICATION UNIT¬«M ERROR

広範囲行き精度/VERALL   ! /VERALL¬ ±  Lifting lever (finger hook) 3 (YSTERESIS (YSTERESIS 戻り誤差   -   Standard accessory (only for models that have a measuring range of 繰返精密度2EPEATABILITY  PASSED % 2EPEATABILITY  PASSED  ¬/VERALL¬MAGNIlCATION¬AND¬LINEARITY -ETHOD¬OF¬INSPECTION-)454/9/¬.O¬SIGN *UDGEMENT¬判定)¬0ASSED¬合格 25.4mm or 50.8mm)  "ASED¬ON¬¬!3-%¬"-  注 ¬規格値には量子化誤差±カウント含まず 4RACEABLE¬TO¬¬.-)*!)34¬BY¬*#33¬.O 4HE¬QUANTIZING¬ERROR¬±¬COUNT ¬IS .)34¬VIA¬.O - EXCLUDED¬FROM¬THE¬SPECIlCATION¬VALUE 

○ ○ ○ ○ × ○ ○× ○× ○ × ○× × ○× ○× × × ○ ×  × × × × ○ × × If dust or coolant gets into the gap between the spindle and main unit while using the ¬%RRORS¬;«M= ○ × × ○ × ○ ○× ○ ○ ○ ○

 指示誤差  ○¬¬50 ׬¬$/7.  位置¬0OSITIONMM  lifting knob, the spindle travel may become rough or the indicator may fail altogether. この検査成績書には安心してご 利用いた だ けますよう出荷時の検査データを記載して Therefore avoid using the ID-C in environments containing dust or coolant mist. -ITUTOYO¬#ORPORATION いますが 、校正証明書取得用にはご利用できません

3 ABS Digimatic Indicator ID-C

SPECIFICATIONS Inch/Metric ISO/JIS Type and ANSI/AGD Type Order No. Measuring range Accuracy*[1 Hysteresis* Repeatability* Measuring force Mass Remarks Resolution .00005"/.0001"/.0005"/0.001mm/0.01mm 543-391 543-391B .5" ±.00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 1.5N or less 170g — 543-392 543-392B .5" ±.00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 1.5N or less 170g — 543-395 543-395B .5" ±.00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 0.7, 0.6, 0.4N or less 170g Low measuring force 543-396 543-396B .5" ±.00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 0.7, 0.6, 0.4N or less 170g Low measuring force — 543-471B 1" ±.00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 1.8N or less 190g — — 543-472B 1" ±.00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 1.8N or less 190g — — 543-491B 2" ±.00020"/0.005mm .00010"/0.002mm .00010"/0.002mm 2.3N or less 260g — — 543-492B 2" ±.00020"/0.005mm .00010"/0.002mm .00010"/0.002mm 2.3N or less 260g — Resolution .0005"/0.01mm 543-401 543-401B .5" ±.0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 0.9N or less 170g — 543-402 543-402B .5" ±.0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 0.9N or less 170g — 543-405 543-405B .5" ±.0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 0.5, 0.4, 0.3, 0.2N or less 170g Low measuring force 543-406 543-406B .5" ±.0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 0.5, 0.4, 0.3, 0.2N or less 170g Low measuring force — 543-475B 1" ±.0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 1.8N or less 190g — — 543-476B 1" ±.0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 1.8N or less 190g — — 543-495B 2" ±.0015"/0.04mm .0010"/0.02mm .0005"/0.01mm 2.3N or less 260g — — 543-496B 2" ±.0015"/0.04mm .0010"/0.02mm .0005"/0.01mm 2.3N or less 260g —

Metric ISO/JIS Type Order No. Measuring range Accuracy*[1 Hysteresis* Repeatability* Measuring force Mass Remarks Resolution 0.001mm/0.01mm 543-390 543-390B 12.7mm 0.003mm 0.002mm 0.002mm 1.5N or less 170g — 543-394 543-394B 12.7mm 0.003mm 0.002mm 0.002mm 0.7, 0.6, 0.4N or less 170g Low measuring force — 543-470B 25.4mm 0.003mm 0.002mm 0.002mm 1.8N or less 190g — — 543-490B 50.8mm 0.005mm 0.002mm 0.002mm 2.3N or less 260g — Resolution 0.01mm 543-400 543-400B 12.7mm 0.02mm 0.02mm 0.01mm 0.9N or less 170g — 543-404 543-404B 12.7mm 0.02mm 0.02mm 0.01mm 0.5, 0.4, 0.3, 0.2N or less 170g Low measuring force — 543-474B 25.4mm 0.02mm 0.02mm 0.01mm 1.8N or less 190g — — 543-494B 50.8mm 0.04mm 0.02mm 0.01mm 2.3N or less 260g —

: ANS/AGD Type Note) Products with an Order No. suffixed “B” have a flat back, and other models have a back with a lug. * Overall hysteresis and repeatability specifications are valid for normal measurement at 20°C, and the quantizing error of ±1 count is excluded. COMMON SPECIFICATIONS • Display: 6-digit LCD, sign • Position detection method: Capacitance type absolute linear encoder • Contact point: Spherical tip SR = 1.5mm (carbide tipped), • Battery: SR44 ( oxide button cell) × 1, part No. 938882 part No. 901312 (for ISO/JIS Type) • Battery life: Approximately 7,000 hours of continuous use part No. 21BZB005 (for ANSI/AGD Type) • Maximum response speed: Not restricted (except for scanning measurement) • Spindle orientation for measurement: • Service temperature range: 0 to 40°C - Standard model that has a 12.7mm measuring range: No restrictions • Storage temperature range: 0 to 60°C - Standard model that has a 25.4mm or 50.8mm measuring range: Normally at any position between the spindle pointing vertically downward to the spindle horizontal. To perform measurement with the spindle pointing above the horizontal requires a reverse-position coil spring (special accessory). - Low measuring force models: See 'Setting measuring force on low measuring force models' on page 5.

4 Setting measuring force on low measuring force models

•543-404/404B/405/405B/406/406B •543-394/394B/395/395B/396/396B Weight Maximum Spindle orientation Spring Weight Maximum Spindle orientation Spring (approximately 0.1 N) measuring force (approximately 0.1 N) measuring force Yes Yes 0.5N Yes Yes 0.8N (0.3+0.4+0.1=0.8) Yes No 0.4N Yes No 0.6N Pointing vertically downward Pointing vertically downward No Yes 0.3N No Yes 0.4N No No 0.2N No No Not guaranteed Horizontal Yes No 0.2N Horizontal Not guaranteed Note) Operation using configurations other than shown above is not guaranteed. Note) Operation using configurations other than shown above is not guaranteed.

DIMENSIONS ISO/JIS Type

ø10.9 28.8 20 19.2 31.5 11 19.2 31.5 11 50.1

5 57.7 85.2

ø59 ø6.5 ø54 ø59 46.5

54.4 0 ø8 -0.009 17 M2.5X0.45 ø59 70

84.8 0

7.3 ø8 -0.009 21.2 7.6 19.5 12.7mm range models

M2.5X0.45 97.3 110.6 7.3 40.8 26 0 ø8 -0.009

25.4mm range models 19.5 65.3

52 M2.5X0.45 7.3

50.8mm range models

ANSI/AGD Type

19.2 ø10.9 28.8 19 31.5 11 19.2 31.5 11 .43" 1.13" 3/4" .76" 1.24" .43" .76" 1.24" .43"

6.35 1/4" 50.1 1.97" 57.7 2.27" 54 2.13" 3.35" 85.2 59 2.32" ø ø 6.5 59 ø 1/ 2.32" ø 4" 44.2 2" 1.74" 0 50.8 ø9.52-0.03 14.7 .58" 59

.375" 2.32" 67.7 2.67" ø 83.85 · Contact point 3.30"

20 7.6 .79" 0 No.4-48 thread .3" ø9.52 -0.03 17.2 .68" .375" 1/4" 95 6.35 · Contact point 3.74" 4.32" 109.65 1/4" 6.35 12.7mm range models 26 No.4-48 thread 42.15 1.66" 1.02" 0 9.52-0.03 17.2 * is the symbol denoting American Gage Design (AGD). .68" .375" It shows conformance to certain dimensions for Dial Indicators, 25.4mm range models as specified in ASME / AGD 2, intended to promote interchangeability. Only applicable to models with an "E" suffix.

52 · Contact point 2.05" 2.62" 66.65 6.35 1/4" No.4-48 thread

50.8mm range models

5 Functions and accessories

Functions • Zero-setting function • 330° rotary display • Data output (INC measurement mode) (when connected to an external device) • Preset function (ABS scale origin setting) 330° 330° From the output terminal, measurement data can The preset value can be changed easily by using the be output to a PC via a compact printer, Digimatic SET (digit movement) and MODE (value change) mini processor DP-1VR, or input tool by pressing buttons. the button below the display. Wireless transmission of measurement data to a PC can also be performed using the measurement data wireless communication system U-WAVE.

• Resolution switching (For 0.001mm or .00005" resolution models) Models with 0.001mm resolution are capable of displaying in 0.01mm resolution. Models with .00005" resolution are capable of displaying in .0001" and .0005" resolution. Select the resolution according to the application.

• Switching the direction The measuring direction can be reversed. Connecting cables for data output (special accessory) 1m: No.905338 2m: No.905409 No.264-504 • Judging the tolerance DP-1VR Performs judgment (OK, +NG, -NG) according to • Display value holding (special accessory) the set upper and lower limit values and displays (when no external device is connected) the result as a symbol. Enlarged display of the OK and NG symbols is possible.

Input tool No.264-012-10 IT-012U (special accessory)

• Calculation: f(x) = Ax Mounting the ID-C on a measuring jig and setting • Function locking the calculation factor (to any value) allows direct Ensures reliability of measurement by locking the measurement without using a conversion table and settings to prevent preset function settings from improves measurement efficiency. being changed by mistake.

Measurement value and Enlarged display of the tolerance judgment tolerance judgment result

• Low battery voltage alarm • Error alarm

6 Standard accessories • Interchangeable contact points for Mitutoyo dial gages • U-WAVE (measurement data wireless communication system) • Operation manual • Digimatic mini processor DP-1VR No. 264-504 • Inspection certificate • Multiplexer MUX-10F, No. 264-002 Shell Flat Needle 1 Lifting lever (finger hook) • Display unit EC-101D, No. 542-007 (Only for models that have a 25.4mm or 50.8mm measuring range) Various types of contact points are available. • Input tool (USB keyboard signal conversion type) • Silver oxide button cell for the monitor: SR44 × 1 IT-012U, No. 264-012-10 Part No. 938882 • Various backs for standard Mitutoyo (2 series) dial gages • Weight (only for low measuring force models) • Reverse-position coil spring Part No. 02ACA571 (for models that have a 25.4mm measuring range) Part No. 02ACA773 6 Special accessories (for models that have a 50.8mm measuring range) 2 Lifting lever • Connecting cable (1m), part No. 905338 Part No. 21EZA198 • Connecting cable (2m), part No. 905409 8 (for models that have a 12.7mm measuring range ISO/JIS Type) Part No. 21EZA199 (for models that have a 12.7mm measuring range ANSI/ADG Type)

3 Lifting cable, part No. 540774 2 7 4 Lifting knob Part No. 21EZA105 (for models that have a 12.7mm measuring range ISO/JIS Type) 4 Part No. 21EZA150 (for models that have a 12.7mm measuring range ANSI/ADG Type) 5 No.7007 Part No. 21EZA197 1 (for models that have a 25.4mm measuring range) • Recommended stands Part No. 21EZA200 5 Dial gage stand, No. 7001 7002 7007 (for models that have a 50.8mm measuring range) 6 Granite comparator stand BSG-30, No. 215-154 7 Comparator stand BSC-30, No. 215-504 8 Comparator stand BSG-20, No. 215-151 3

Various Digimatic Indicators

2

1 ID-C: Standard Digital Indicator 5 2 ID-N/B: waterproof, 35mm slim body with various functions 3 3 ID-H: infrared remote controller, high accuracy, and various functions 4 ID-S: cost-effective type that has basic functions 1 5 ID-U1025: general-purpose type that has a 25.4mm measuring range 4 6 ID-C112RB: has a built-in calculation function 7 ID-C112A: has a peak hold function 8 8 ID-C112GB: internal diameter measuring 7 6 instrument dedicated to cylinder gages

7 Application Products Application Products

ABS Digimatic Thickness Gage

547-300S 547-320S 547-400S

Unit: mm

• For one-touch quick measurement of the thickness of small parts, papers, and felt 120 • Rust-free ceramic contact point and anvil (except No. 547-401) ø10 30 ø10 85 175 547-301 547-321

Inch/Metric ANSI/AGD Type Parallelism of contact point Order No. Resolution Measuring range Throat depth Contact point and anvil and anvil Accuracy Measuring force 547-300S .0005"/0.01mm 0~.4"/0~10mm 30mm ø10mm flat .0005" or less ±.001" 1.5N or less 547-320S .0005"/0.01mm 0~.4"/0~10mm 120mm ø10mm flat .0005" or less ±.001" 1.5N or less 547-400S .00005"/0.001mm 0~.47"/0~12mm 21mm ø6.3mm flat (carbide tipped) .0001" or less ±.0001" 3.5N or less

Metric ISO/JIS Type Parallelism of contact point Order No. Resolution Measuring range Throat depth Contact point and anvil and anvil Accuracy Measuring force 547-301 0.01mm 0~10mm 30mm ø10mm flat 10µm or less ±20µm 1.5N or less 547-321 0.01mm 0~10mm 120mm ø10mm flat 10µm or less ±20µm 1.5N or less 547-401 0.001mm 0~12mm 21mm ø6.3mm flat (carbide tipped) 3µm or less ± 3µm 3.5N or less Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice. 2. The accuracy specification does not include the quantizing error of ±1 count. 3. Left-handed models can be supplied to special order.

8 ABS Digimatic Lens Meter

Unit: mm

Spherical contact Flat contact Flat contact Contact point point point point 9.3 ø6 SR2 9.3 Sø4 spherical ø4.8 SR3 Anvil Anvil Anvil contact point 30 Standard accessory Anvil adjustment: 30.3 (Throat depth) Concave lens Convex lens Moon lens 12 mm SR3 85

• Designed for measuring the thickness of concavo-convex lenses and flat objects • The thickness of flat objects can be measured by replacing the anvil. • Includes a spherical contact point.

9.3 30 ø6 ø4.8 Inch/Metric ANSI/AGD Type

SR2 30 Order No. Resolution Measuring range Throat depth Anvil adjustment Accuracy Measuring force 547-312S Anvil displacement: 12 mm 547-312S .0005"/0.01mm 0~.4"/0~10mm 30mm 12mm SR3±.001" or less 851.5N or less

Metric ISO/JIS Type Order No. Resolution Measuring range Throat depth Anvil adjustment Accuracy Measuring force 547-313 0.01mm 0~10mm 30mm 12mm ±20µm or less 1.5N or less Note) The accuracy specification does not include the quantizing error of ±1 count. Left-handed models can be supplied to special order.

ABS Digimatic Pipe Gage

Unit: mm Contact point

ø3 ø 3 • Designed for measuring the thickness of pipes and curved boards Effective Tip: ø3.5 throat depth Anvil 20 21 85

Inch/Metric ANSI/AGD Type Minimum inside Order No. Resolution Measuring range Throat depth diameter of pipe Accuracy Measuring force 547-361S 547-361S .0005"/0.01mm 0~.4"/0~10mm 20mm ø3.5mm ±.001" or less 1.5N or less ø 3

Metric ISO/JIS Type アンビル 有効差し 球ø3.5 込み深さ Minimum inside 21 Order No. Resolution Measuring range Throat depth diameter of pipe Accuracy Measuring force 547-360 0.01mm 0~10mm 20mm ø3.5mm ±20µm or less 1.5N or less Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice. 2. The accuracy specification does not include the quantizing error of ±1 count. 3. Left-handed models can be supplied to special order.

9 Application Products

Unit: mm ABS Digimatic Groove Gage

Contact point • Best suited for measuring the depth of narrow grooves on 1 6 Anvil cylindrical workpieces 6 • The contact point and measuring face of the anvil are 1mm thick blades. 30.3 (Throat depth) 85 Inch/Metric ANSI/AGD Type Throat Contact point and anvil Order No. Resolution Measuring range depth dimensions (W × D) Accuracy Measuring force 547-316S .0005"/0.01mm 0~4"/0~10mm 30mm 6.5mm x 1mm ±.001" or less 1.5N or less 30 ø6.5 5

Metric ISO/JIS Type 5 Throat Contact point and anvil Order No. Resolution Measuring range 1 Accuracy Measuring force depth dimensions (W × D) 85 547-315 0.01mm 0~10mm 30mm 6.5mm x 1mm ±20µm or less 1.5N or less 547-316S Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice. 2. The accuracy specification does not include the quantizing error of ±1 count. 3. Left-handed models can be supplied to special order.

Unit: mm

ABS Digimatic Depth Gage ø59

• Suitable for measuring the depth of holes, narrow grooves, and steps. • The lifting lever can be used either on the left or right sides. (105)

(67) ø16 (35) (11) 17

(10) SR1.5 ø5 547-218S ø6 A Inch/Metric ANSI/AGD Type Measuring Base Order No. Resolution Measuring Stroke Accuracy Contact point: Carblde- Extension rods range force Length Width Flatness tipped ball 547-217S .0005"/0.01mm 0~8" .5" ±.001" or less 1.5N or less 2.5" .63" .0002" or less 4 pcs. (.5",1",2",4") 547-218S .0005"/0.01mm 0~8" .5" ±.001" or less 1.5N or less 4" .63" .0002" or less 4 pcs. (.5",1",2",4") 21JAZA242 547-257S .00005"/0.001mm 0~8" .5" ±.0002" or less 1.5N or less 2.5" .63" .00008" or less 4 pcs. (.5",1",2",4") 547-258S .00005"/0.001mm 0~8" .5" ±.0002" or less 1.5N or less 4" .63" .00008" or less 4 pcs. (.5",1",2",4")

Metric ISO/JIS Type Measuring Base Contact point: Carblde- Order No. Resolution Measuring Stroke Accuracy Extension rods range force Length Width Flatness tipped ball 547-211 63.5mm 0.01mm ±20µm 1.5N or less 5µm or less 547-212 101.6mm 0~200mm 12mm 16mm 21JAA224 5 pcs. 547-251 63.5mm (10, 20, 30, 30, 100mm) 0.001mm ±5µm 1.5N or less 2µm or less 547-252 101.6mm Note) The accuracy specification does not include the quantizing error of ±1 count.

10 Unit: mm ABS Digimatic Bench Gage 40

• The support plate allows easy reading by tilting the anvil. • Carbide measuring faces (for the contact point and anvil) ø59 92 • The lifting lever can be used either on the left or right sides. 10 60 Effective throat depth ø8 ø6.3 55 45 5

547-066S Support plate ø20 Flat anvil Inch/Metric ANSI/AGD Type Order No. Indicator stroke Resolution Remarks (contact point) Effective throat depth Workpiece height Accuracy Measuring force 547-066S .5" .0005"/0.01mm .248" DIA flat type .59" 1" ±.001" or less 1.5N or less

Metric ISO/JIS Type Order No. Indicator stroke Resolution Workpiece height Effective throat depth Anvil adjustment Accuracy Measuring force 547-064 12mm 0.01mm ø20mm 15mm 13mm ±20µm or less 1.5N or less Note) The accuracy specification does not include the quantizing error of ±1 count.

Unit: mm

ABS Digimatic Upright Gage

• Best suited for inspection of small parts at a site • Carbide ball contact point • The lifting lever that is a standard accessory for No. 547-054, Anvil 547-034S can be used either on the left or right sides. (hardened steel) measuring range Effective

SR1.5 ø40 115 12 35 547-035S Center of anvil 1 Center of 60 Measuring depth 45 20 contact point 95 Inch/Metric ANSI/AGD Type Order No. Resolution Measuring range Anvil Workpiece height Accuracy Measuring force 547-034S .0005"/0.01mm .5" 1.57" DIA steel type 1.2" ±.001" or less 547-033S .00005"/0.001mm .5" 1.97" DIA ceramic type 1.2" ±.0001" or less 1.5N or less 547-035S .00005"/0.001mm .5" 1.57" DIA steel type 1.2" ±.0001" or less

Metric ISO/JIS Type Order No. Resolution Measuring range Anvil Workpiece height Accuracy Measuring force 547-054 0.01mm 12.7mm ø40mm (steel type) ±20µm or less 547-053 0.001mm 12.7mm ø50mm (ceramic type) 30mm ± 3µm or less 1.5N or less 547-055 0.001mm 12.7mm ø40mm (steel type) ± 3µm or less Note) 1. The lifting lever (part No. 21EZA198) is a standard accessory for 547-054. 2. The lifting lever (part No. 21EZA199) is a standard accessory for 547-034S. 3. The lifting cable (part No. 540774) is a standard accessory for 547-055, 547-033S, 547-035S. 4. The accuracy specification does not include the quantizing error of ±1 count. • The ABS (ABSOLUTE) scale used in these products is a capacitance type absolute encoder. Its patent has been registered in Japan, the U.S., the U.K., Germany, and .

11 Export permission by the Japanese government may be required for exporting our products according to the Foreign Exchange and Foreign Trade Law. Please consult our sales office near you before you export our products or you offer technical information to a nonresident.

One Number to Serve You Better 1-888-MITUTOYO (1-888-648-8869)

Aurora, Illinois (Corporate Headquarters)

Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this printed matter as Westford, Massachusetts well as other technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs. The Huntersville, North Carolina stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. In addition, the latest applicable version of our General Trading Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive. Mason, Ohio Mitutoyo products are subject to US Export Administration Regulations (EAR). Re-export or relocation of Mitutoyo products may require prior approval by an Plymouth, Michigan appropriate governing authority. MitutoyoCity of Industr Corporationy, California Trademarks and Registrations Designations used by companies to distinguish their products are often claimed as trademarks. In all instances where Mitutoyo America Corporation is aware 20-1, Sakado 1-chome, of a claim, the product names appear in initial capital or all capital letters. The appropriate companies should be contacted for more complete trademark and Takatsu-ku, Kawasaki-shi, registration information. Kanagawa 213-8533, Japan We reserve the right to change specifications and prices without notice. T +81 (0) 44 813-8230 F +81 (0) 44 813-8231 © 2009 Mitutoyo America Corporation, Aurora IL 0409-09 Printed in USA, 2009 Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this pamphlet, as well as other http://www.mitutoyo.co.jp technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs, dimensions and weights. The stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. Only quotations submitted by ourselves may be regarded as definitive. Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this pamphlet, as well as other Our products are classified as regulated items under Japanese Foreign Exchange and Foreign Trade Law. Please consult us in advance if you wish to export our products to technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs, dimensions and weights. any other country. If the purchased product is exported, even though it is not a regulated item (Catch-All controls item), the customer service available for that product The stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. Only quotations submitted by ourselves may be affected. If you have any questions, please consult your local Mitutoyo sales office. may be regarded as definitive.