DuPont™

DUPONT SELF-ADHERED FLASHING SYSTEMS INSTALLATION GUIDELINES FOR BUILDINGS GREATER THAN 4 STORIES AND HIGH PERFORMANCE INSTALLATIONS OF ANY HEIGHT REVISION 6/18 DuPont Self-Adhered Flashing Systems Installation Guidelines

Table of Contents Note Note...... 2 This installation guideline outlines recommended installation techniques and details for ™ ™ ® Applicable Products...... 3 DuPont self-adhered flashing products and where applicable, DuPont CommercialWrap and/or DuPont™ Tyvek® CommercialWrap D, referred to in this Warranty...... 3 document as DuPont™ Tyvek® air and water barriers. General Instructions ...... 3 Key Installation Requirements for Drainable Window / Door Installation Under the Limited Product and Labor Warranty...... 4 Installation Methods for DuPont Flashing Systems products AFTER DuPont™ Tyvek® Air and Water Barrier is Installed...... 6 Non-Flanged Window...... 6 Non-Flanged Window with Lintel and Brick Facade...... 14 Brick Mold Window...... 26 Integral Flanged Window...... 33 Non-Flanged Window Using DuPont™ StraightFlash™ VF...... 39 Store front Window on Slab...... 46 Store front Window on Knee Wall...... 52 Alternate Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method A)...... 59 Alternate Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method B)...... 65 Alternate Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method C)...... 71 Installation Instructions for Through Wall Flashing...... 77 Through Wall Flashing – DuPont™ Tyvek® Interface ...... 77 Base of wall...... 77 Shelf angle...... 77 Parapet wall with brick...... 78 Penetrations...... 79 Proper overlap for water management...... 83

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 2 DuPont Self-Adhered Flashing Systems Installation Guidelines

Applicable Products Warranty Please refer to the DuPont Weatherization Products 10-Year Limited Warranty for DuPont™ Self-Adhered Flashing Systems products Buildings Greater Than 4 Stories. For buildings less than 5 stories, and low-rise PRODUCT WIDTH multi-family buildings less than 6 stories, please refer to the DuPont Weatherization DuPont™ FlexWrap™ NF 6 in Products 10-Year Limited Warranty for Buildings Less Than 5 Stories and Low-Rise 9 in Multi-Family Residential Buildings Less Than 6 Stories.

™ ™ DuPont FlexWrap EZ 2.75 in General Instructions DuPont™ StraightFlash™ 4 in ™ 9 in DuPont self-adhered flashing products should be installed on clean, dry surfaces that are free of frost. Wipe surfaces to remove moisture, dirt, grease and other debris that DuPont™ StraightFlash™ VF 6 in could interfere with adhesion. DuPont™ Flashing Tape 4 in 6 in Apply pressure along entire surface of flashing for a good bond using firm hand pressure, 9 in 12 in J-roller, or alternate without sharp edges (such as a carpet tuck tool) to assist with application of uniform pressure during installation of DuPont™ self-adhered flashing Required Materials Based on Project Requirements, systems products. Details, and Specifications* Remove all wrinkles and bubbles by smoothing surface and repositioning as necessary. PRODUCT When flashing the sill area for windows and doors, DuPont recommends the use of 6” DuPont™ Adhesive/Primer wide DuPont™ FlexWrap™ NF for 2”x 4” framing and 9” wide DuPont™ FlexWrap™ NF for DuPont™ Tyvek® Tape 2” x 6” framing. When rigid back dams are required or desired, an option would be to ™ ® DuPont Tyvek Wrap Cap Fasteners or recommended fastening system use a ¾” corner guard (back dam) cut to the length of the sill and nail into place on the DuPont™ Sealant for Tyvek® Fluid Applied System† interior edge of the sill prior to installation of 9” wide DuPont™ FlexWrap™ NF. Then DuPont™ Window & Door Foam install 9” wide DuPont™ FlexWrap™ NF over sill and corner guard back dam. Backer Rod Before applying 3” DuPont™ Tyvek® Tape, surfaces should be dry and clean. During Brushes for Surface Preparation installation apply firm, even pressure with hand or “J” roller.

J-Roller In lieu of temporarily taping, DuPont™ Tyvek® flaps at window head and jambs can be “L” shaped back dam is a 3/4” corner guard (used on interior gypsum) tucked under the DuPont™ Tyvek® air and water barrier.

Sealant* 3” DuPont™ Tyvek® Tape should not be used to terminate DuPont™ Tyvek® flaps at *Apply per manufacturers’ guidelines. For non DuPont products, DuPont assumes no liability in use of window jambs and head when the building envelope design requirements exceed recommended products; installers need to evaluate suitability of recommended products in their end-use applications. ASTM E1677, 65 mph equivalent structural load and 15 mph equivalent wind-driven rain water infiltration resistance. †Refer to the DuPont™ Tyvek® Fluid Applied Flashing Installation Guidelines (K-29397) for more information about the use of DuPont™ Fluid Applied products with DuPont™ Tyvek® air and water barriers. 4” DuPont™ Flashing Tape is an alternative to 3” DuPont™ Tyvek® Tape where specified in the DuPont™ Tyvek® Air and Water Barrier Installation Guidelines for Buildings Greater Than 4 Stories. Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 3 DuPont Self-Adhered Flashing Systems Installation Guidelines

Door and window rough sill framing must be level or slightly sloped to the exterior to Packaged Terminal Air Conditioners (PTAC) units should be flashed in accordance with ensure proper drainage to the exterior. non-flanged window details (pages 7-14) or with DuPont™ StraightFlash™ VF pursuant to the detail for brick mold windows (page 26-33). DuPont™ Window & Door Foam can be used in lieu of sealant to create a continuous seal around the interior perimeter of the window openings. Refer to the DuPont™ Additional CAD technical drawings are available at www.weatherization.tyvek.com. Window & Door Foam FAQ posted on www.weatherization.tyvek.com for additional usage information. Please call 1-800-44-Tyvek (800-448-9835), visit www.weatherization.tyvek.com, or consult your local DuPont™ Tyvek® Specialist for additional information and installation ™ ™ DO NOT STRETCH DuPont FlexWrap NF when installing along sills or jambs. support. DuPont™ FlexWrap™ NF is only intended to be stretched when covering corners or curved sections. Key Installation Requirements for Drainable Window / Door DuPont™ self-adhered flashing products perform best when installed at temperatures above 25°F (–4°C). Installation Under the Limited Product and Labor Warranty When flashing windows or doors, the following principles must be followed: Avoid placing DuPont™ Tyvek® Wrap Cap Fasteners where flashing will be installed; however, DuPont™ Tyvek® Wrap Cap Fasteners can be applied over the flashing. • When installed properly, DuPont™ StraightFlash™, DuPont™ StraightFlash™ VF, DuPont™ FlexWrap™ NF, and DuPont™ Flashing Tape provide nail sealability at For extreme/coastal exposures installation of a high pressure skirt is recommended to window/door openings to help protect critical window-wall interfaces. Metal sill pan help prevent water intrusion at the sill or threshold. flashing may be used, but must not replace flexible sill flashing that provides nail For high pressure design loads, the use of DuPont™ StraightFlash™ with wrap cap sealability. screws is required to secure the head flap of the windows. • DuPont™ self-adhered flashing systems products comply with AAMA 711-13, Adverse weather conditions or cold temperatures may require use of a primer to Voluntary Specification for Self Adhering Flashing Used for Installation of Exterior promote adhesion of DuPont™ self-adhered flashing products to most common building Wall Fenestration Products, which has a modified version of ASTM D 1970 and it is materials. Concrete, masonry, and fiber-faced exterior gypsum board require the use of more representative for vertical wall applications. DuPont™ Adhesive/Primer. • Ensure that sill flashing does not slope to the interior. An exterior slope is recommended, but not required. For window or door openings greater than 6 feet wide (commercial installations only): • Direct water onto an acceptable air and water barrier drainage plane with an A 3-piece sill and head detail is allowed using DuPont™ StraightFlash™ and DuPont™ unobstructed path to the exterior of the wall. Provide a drainage path for any water FlexWrap™ NF corners. DuPont™ StraightFlash™ should be applied the length of the sill intrusion through the window/door attachment system that collects at the sill. prior to placing the FlexWrap™ NF corners. The FlexWrap™ NF corners should be at • Properly integrate flashing with acceptable DuPont™ Tyvek® air and water barrier in least 12” long allowing for 6” up the jamb and 6” of overlap on the StraightFlash™ sill accordance with the instructional drawing. Self-adhered flashing must be applied flashing . When applying the 3-piece flashing detail to the head of the opening, the with a minimum 2” lap onto the air and water barrier. ™ ™ StraightFlash head piece should be applied prior to installing the FlexWrap NF • Review the sealant manufacturer’s literature or label to confirm that the products ™ corner flashing. Minimum overlapping of the StraightFlash head flashing and jamb used have the chemical and adhesive properties necessary for use with the DuPont flashing should be a minimum of 6”. flashing materials. Refer toChemical Compatibility of Representative Building Sealants (K-27282) for more information about chemical compatibility.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 4 DuPont Self-Adhered Flashing Systems Installation Guidelines

• DuPont requires that DuPont™ FlexWrap™ EZ, FlexWrap™ NF, StraightFlash™, and StraightFlash™ VF be covered within nine months (270 days) of installation. DuPont requires that DuPont™ Flashing Tape be covered within four months (120 days) of installation. • Ensure the sealant materials meet the installation temperature requirements of the sealant manufacturer. • Properly prepare all surfaces (remove dirt, dust, or moisture, etc.) per manufacturer’s recommendations. • Barrier installations (full perimeter seal on exterior) are acceptable only in the following instances: – Slab on grade doors, store front windows, or other systems with built-in drainage mechanisms that have potential for exposure to standing water – Surface barrier wall systems with non-water sensitive framing material (i.e., CMU walls) – Very low wind / rain exposure regions (southwest / desert) that follow AAMA 2400 installation guideline

• Ensure that window / door and flashing system design takes into account common factors that will impact performance, such as: – Climate considerations: Rainfall, Wind, Temperature (hot / cold cycles), Humidity – Building design: Window / Wall Design (overhangs, recessed openings, bump- outs), Wall Assembly (wood frame or masonry), Window System (wood or vinyl), New Construction or Replacement Window drainage path – UV exposure prior to the construction of the exterior facade

– Compliance with fire resistance code requirements. For more information about NFPA 285 compliant wall assemblies utilizing DuPont™ Tyvek® Air and Water Barrier products visit www.weatherization.tyvek.com

• Field testing the window / door and wall installation as a complete system is a recommended best practice. • Use of trained installers is highly recommended.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 5 DuPont Self-Adhered Flashing Systems Installation Guidelines

Installation Methods for DuPont Flashing Systems products AFTER DuPont™ Tyvek® Air and Water Barrier is Installed

Non-Flanged Window Method applies to following products: • DuPont™ StraightFlash™ • DuPont™ FlexWrap™ NF

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically Fastened Air and Water or slightly below the sill framing to allow for positive drainage. Barrier Installation Guidelines for Buildings Greater Than 4 Stories that can be found at www.weatherization.tyvek.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 6 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 STEP 4 Prepare air and water barrier for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure flap with tape. A. Cut an opening in the DuPont™ Tyvek® air and water barrier using a square cut around B. Temporarily secure DuPont™ Tyvek® air and water barrier with DuPont™ Tyvek® Tape the perimeter of the rough opening. around rough opening before flashing is installed to help facilitate flashing B. Cuts should be made along the dashed indicated lines. (Ensure that the DuPont™ installation. Tyvek® air and water barrier is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation.

8“

A

B

8“

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 7 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 6 A. Prepare the sill flashing by cutting a piece of DuPont™ FlexWrap™ NF that is at least A. Install the sill flashing. Remove the largest strip of release , align the flashing 12” longer than sill length. Use 6” DuPont™ FlexWrap™ NF for 2” x 4” framing and 9” with the interior edge of sill, and install into rough opening across sill and up jambs DuPont™ FlexWrap™ NF for 2” x 6” framing. (min 6”). Apply working from the middle of the sill towards the sides. Secure DuPont™ FlexWrap™ NF tightly into the corners by first working in along the sill B. Inspect installation surface to ensure surface is free of dirt or substances that could before adhering up the jambs. interfere with adhesion as well as any sharp protrusions. B. Cover holes in studs with patches of DuPont™ StraightFlash™. DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

B

DO NOT STRETCH

B A 6” A

No gap in corner Sill length +12” Window jamb

DuPont™ FlexWrap™ NF

WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 8 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 7 STEP 8 A. Remove second half of the release paper. A. Cut the jamb flashing the vertical length of the rough opening. Jamb flashing should B. Fan DuPont™ FlexWrap™ NF at bottom corners and adhere onto face of wall. be long enough to overlap the sill flashing by at least 2” and be overlapped by future head flashing by at least 2”. C. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles ™ ™ and bubbles by smoothing surface and repositioning as necessary. B. Wrap 9” DuPont StraightFlash into the rough opening at each jamb and onto wall face. The flashing should align with the interior edge of the jamb framing.

2“ minimum overlap

A

B

INCORRECT CORRECT DuPont™ FlexWrap™ NF DuPont™ StraightFlash™ reverse flashed overlaps DuPont™ FlexWrap™ NF

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 9 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 9 STEP 10 A. Apply DuPont™ Adhesive/Primer to the top of the jambs and exposed sheathing. A. Adhere DuPont™ FlexWrap™ NF to the head using the same installation process as shown in steps 6 and 7 for the sill flashing. Make sure the DuPont™ FlexWrap™ NF is cut long enough to overlap the jamb flashing by at least 2”.

DuPont™ Adhesive/Primer A

INCORRECT CORRECT DuPont™ FlexWrap™ NF DuPont™ StraightFlash™ reverse flashed overlaps DuPont™ FlexWrap™ NF

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 10 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 11 STEP 12 A. If angled caulk stops are used to contain perimeter sealant, they should be attached A. As a best practice for high exposure areas, install metal drip cap above the head joint to window along side jambs and head prior to installation. when specified. The sill will be left open prior to window installation to allow for drainage of incidental B. Apply a strip of 4” DuPont™ StraightFlash™ over the drip cap. moisture. B. Install window per manufacturer’s installation instructions. Apply an exterior perimeter seal using backer rod and sealant along the jambs and head of the window opening. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow for drainage.

Drip cap (optional)

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 11 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 13 STEP 14 A. Flip down the head flap and trim 1”-2” above the window opening. Terminate flap Interior View along the top of the window with 3” DuPont™ Tyvek® Tape or 4” DuPont™ A. Create a continuous perimeter seal using backer rod and sealant or DuPont™ Window ™ ™ ® StraightFlash . (See General Instructions for when 3” DuPont Tyvek Tape is and Door Foam on window interior to resist air and water infiltration. allowed). B. Apply 4” DuPont™ StraightFlash™ over the diagonal seams. C. For high performance designs or areas of extreme exposure use 4” DuPont™ StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

A B

C

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 12 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 14-A (OPTIONAL ALTERNATE BACK DAM PART 1) STEP 14-B (OPTIONAL ALTERNATE BACK DAM PART 2) A. While the sealant is still wet, as a best practice, install an “L” shaped back dam cut A. Install retention clips around the window to permanently secure it in the rough the width of the rough opening so that it contacts the sealant bead and rear of opening as recommended by window manufacturer to complete installation. window. Apply sealant along four sides of the exposed back dam. OPTIONAL: B. When the facade is complete, place a continuous sealant bead integrating the Apply sealant along all four sides in lieu of back dam. NOTE: For alternate back window to the facade. dam see the Brick Mold Installation Guide, Steps 2 and 7, later in this document.

Flush with window Towards Towards exterior interior

DuPont™ FlexWrap™ NF sill (side view)

Seal backdam to window with sealant

A

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 13 DuPont Self-Adhered Flashing Systems Installation Guidelines

Non-Flanged Window with Lintel and Brick Facade Method applies to following products: • DuPont™ StraightFlash™ • DuPont™ FlexWrap™ NF

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically Fastened Air and Water Barrier or slightly below the sill framing to allow for positive drainage. Installation Guidelines for Buildings Greater Than 4 Stories that can be found at www.weatherization.tyvek.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 14 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 STEP 4 A. Cut an opening in the DuPont™ Tyvek® air and water barrier using a full cut out around A. Install the sill flashing. Remove the largest strip of release paper, align the flashing the perimieter of the opening. with the interior edge of sill, and install into rough opening across sill and up jambs B. Temporarily secure DuPont™ Tyvek® air and water barrier with DuPont™ Tyvek® Tape (min 6”). Apply working from the middle of the sill towards the sides. Secure ™ ™ around rough opening before flashing is installed to help facilitate flashing installation. DuPont FlexWrap NF tightly into the corners by first working in along the sill before adhering up the jambs. C. Prepare the sill flashing by cutting a piece of DuPont™ FlexWrap™ NF that is at least 12” longer than sill length. Use 6” DuPont™ FlexWrap™ NF for 2” x 4” framing and 9” DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS. FlexWrap™ NF for 2” x 6” framing. D. Inspect installation surface to ensure surface is free of dirt or substances that could interfere with adhesion as well as any sharp protrusions.

DO NOT STRETCH

No gap in corner

6” Window jamb

DuPont™ B FlexWrap™ NF C

WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

Sill length +12”

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 15 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 6 A. Remove second half of the release paper. A. Cut the jamb flashing the vertical length of the rough opening. Jamb flashing should B. Fan DuPont™ FlexWrap™ NF at bottom corners and adhere onto face of wall. be long enough to overlap the sill flashing by at least 2” and be overlapped by future head flashing by at least 2”. C. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles ™ ™ and bubbles by smoothing surface. B. Wrap 9” DuPont StraightFlash into the rough opening at each jamb and onto wall face. The flashing should align with the interior edge of the jamb framing.

2“ minimum overlap

INCORRECT CORRECT DuPont™ FlexWrap™ NF DuPont™ StraightFlash™ reverse flashed overlaps DuPont™ FlexWrap™ NF

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 16 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 7 STEP 8 A. Adhere DuPont™ FlexWrap™ NF to the head using the same installation process as A. Cut flap in the DuPont™ Tyvek® air and water barrier. ™ ™ shown in steps 4 and 5 for the sill flashing. Make sure the DuPont FlexWrap NF is B. Apply DuPont™ Adhesive/Primer to exposed sheathing. cut long enough to overlap the jamb flashing by at least 2 inches. C. Install lintel on masonry as required. B. OPTIONAL: For some facades, and when specified by the architect, exterior insulation should be added at this time. DuPont™ Tyvek® CommercialWrap® D is specially engineered to provide an enhanced drainage plane and is recommended in these situations.

A

B

C A

CONTINUOUS BACKER ROD AND SEALANT

BACKER ROD AND SEALANT

DUPONT™ FLEXWRAP™ NF SILL

BRICK FACADE DUPONT™ TYVEK® AIR AND WATER BARRIER

INCORRECT CORRECT EXTERIOR ™ ™ ™ ™ DuPont FlexWrap NF DuPont StraightFlash SHEATHING reverse flashed overlaps DuPont™ FlexWrap™ NF

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 17 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 9 STEP 9 (ALTERNATE) Head Detail Using Metal Pan Flashing Head Detail Using Through Wall Flashing A. Install corrosion-resistant metal pan with drip and soldered/sealed end dams above A. Embed through wall flashing end dams in sealant and install along outer edge of lintel. Extend flashing beyond the end of lintel. lintel. B. Install 9” wide strip of DuPont™ StraightFlash™ to bridge between the exterior B. Install through wall flashing with a minimum of 3” adhering to the wall sheathing, sheathing and the metal pan flashing. Maintain a minimum of 3” contact between then overlapping the lintel. Extend the through wall flashing a minimum of 1/4” the DuPont™ StraightFlash™ and the primed exposed sheathing surface. beyond the outside edge of the lintel to form a drip edge. C. Cut a vertical slit in the DuPont™ StraightFlash™ to accommodate the vertical edge C. Apply sealant along the edges of the through wall flashing. of the metal pan. D. Install an additional layer of either 4” or 9” DuPont™ StraightFlash™ over the first layer of DuPont™ StraightFlash™ if necessary to achieve the 3” minimum contact to the exposed exterior sheathing. The overlap should be a minimum of 1”.

D

B C B C A A

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 18 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 10 STEP 11 A. Fold head flap back into place. A. Anchor the non-corrosive metal sill pan flashing to the wall and integrate to the ™ ® ™ ™ B. Tape along bottom edge of cut in DuPont™ Tyvek® air and water barrier with DuPont™ DuPont Tyvek air and water barrier with 4” DuPont StraightFlash . StraightFlash™. C. Use 4” wide DuPont™ StraightFlash™ at diagonal cut in DuPont™ Tyvek® air and water barrier to secure head flap.

2” min DuPont™ Tyvek® Tape (optional)

4” DuPont™ StraightFlash™

B A Metal sill C pan flashing

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 19 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 12 A. Install remaining masonry with weeps along flashing. B. Install window per manufacturer’s instructions. C. Seal all four sides of the perimeter of the window. DO NOT SEAL ANY WEEPS OF WINDOW FRAME.

C

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 20 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 13 STEP 13-A (OPTIONAL ALTERNATE BACK DAM PART 1) Interior View A. While the sealant is still wet, as a best practice, install an “L” shaped back dam cut A. Create a continuous perimeter seal using backer rod and sealant or DuPont™ Window the width of the rough opening so that it contacts the sealant bead and rear of and Door Foam rod and sealant on window interior to resist air and water infiltration. window. Apply sealant along four sides of the exposed back dam. OPTIONAL: Apply sealant along all four sides in lieu of back dam. NOTE: For alternate back dam see the Brick Mold Installation Guide, steps 2 and 7, later in this document.

Flush with window Towards Towards exterior interior

DuPont™ FlexWrap™ NF sill (side view)

Seal backdam to window with sealant

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 21 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 13-B (OPTIONAL ALTERNATE BACK DAM PART 2) Optional Jamb Detail (top view) A. Install retention clips around the window to permanently secure it in the rough NOTE: For other CAD details visit www.weatherization.tyvek.com opening as recommended by window manufacturer to complete installation.

A

DUPONT™

DUPONT™

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 22 DuPont Self-Adhered Flashing Systems Installation Guidelines

Sill Detail (side view) Metal Through Wall Flashing

DUPONT™ NF

USE SEALANT TO SEAL DUPONT™ FLEXWRAP™ NF TO WINDOW FRAME

DUPONT™ NF

NF

THROUGH WALL FLASHING OR

INTERIOR EXTERIOR

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 23 DuPont Self-Adhered Flashing Systems Installation Guidelines

ALTERNATE HEAD DETAIL (top view) Floating lintel after window flashing

SEALANT

THROUGH WALL FLASHING

DRIP CAP

DRIP EDGE

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 24 DuPont Self-Adhered Flashing Systems Installation Guidelines

Alternate for Lintels attached prior to window flashing

Side View 9” DUPONT™ Top View STRAIGHTFLASH™ EXTERIOR BACKER ROD SHEATHING AND SEALANT

DUPONT™ TYVEK® AIR AND WATER BARRIER

BRICK FACADE

3” DUPONT™ TYVEK® TAPE OR DUPONT™ SELF-ADHERED FLASHING PRODUCT BACKER ROD THROUGH WALL AND SEALANT FLASHING OR DRIP CAP SET IN SEALANT

DUPONT™ 2”X 2” METAL FIELD CUT BRICK TYVEK® AIR ANGLE TO RETURN AND WATER MATCH WINDOW BARRIER SEALANT BEAD

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 25 DuPont Self-Adhered Flashing Systems Installation Guidelines

Brick Mold Window STEP 1 ™ ® This installation guide can also be used for windows with field applied nailing fins. Prepare DuPont Tyvek air and water barrier for window installation: Method applies to following products: A. Make an “I-Cut” in the DuPont™ Tyvek® air and water barrier (a modified I-Cut is also acceptable). For an “I-Cut” begin with a horizontal cut across the bottom and the top • DuPont™ StraightFlash™ VF of the window frame (for round top windows, cut from the center cut straight down ™ ™ • DuPont FlexWrap NF to the sill. B. Cut two 45° slits a minimum of 8” from the corner of the header to create a flap above the rough opening to expose sheathing or framing members and to allow head flashing installation (see step 5). Flip head flap up and temporarily secure with DuPont™ Tyvek® Tape. Some windows and flashing widths may require longer slits due to window shape. C. Fold side flaps into rough opening, cut excess flaps, and secure. NOTE: Side flaps should cover interior facing framing stud.

Exterior Exterior Interior

8“ minimum

B B

C 8“ minimum A

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 26 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 2 A. Cut DuPont™ FlexWrap™ NF at least 12” longer than width of rough opening sill. Center release paper Outer release B. Fold to break perforation. Remove center piece of release paper. Align 6” DuPont™ paper B FlexWrap™ NF with interior edge of sill framing, and adhere into rough opening along sill and up jambs (min 6” on each side). OPTIONAL BACK DAM: Fold 9” DuPont™ FlexWrap™ NF to break perforation. Remove center piece of release paper. Cover horizontal sill leaving 1” of overhang on inside edge of sill for back dam, and adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” overhang of release paper on DuPont™ FlexWrap™ NF inside rough Release paper opening to finish back dam after window installation. for backdam C. Remove outer release paper. D. Flex DuPont™ FlexWrap™ NF at bottom corners onto face of wall. Fold to break scores OPTIONAL BACKDAM DETAIL WHEN USING 9” WIDE DUPONT™ FLEXWRAP™ NF

No gap in corner

Window jamb

DuPont™ FlexWrap™ NF

1“ Overhang WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

DO NOT STRETCH Sill length +12” 6“ A minimum

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 27 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 A. Prepare head flashing by cutting a piece of DuPont™ StraightFlash™ VF at least 12” LONGER than the head length. B. Break the scored release paper on one side of the head flashing by folding it back and forth upon itself. C. Center the flashing on the window head and position so that it contacts the window Scored release Paper frame and interior side of the brick mold. Remove the outer release paper and adhere the flashing to the window frame. Use the inner release paper to form a tight seal in the corner where the brick mold attaches to the window frame. D. Remove the inner release paper and adhere the flashing to the back of the brick mold and the window casing. E. At the corner of the window frame, cut the DuPont™ StraightFlash™ VF along the corner at a 45° angle. F. Fold the DuPont™ StraightFlash™ VF down flat against the brick mold. DuPont™ StraightFlash™ VF

A B F D

C

E 45°

Window interior Window interior

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 28 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 4 D. Remove the outer release paper and adhere the flashing to the window frame. Use A. Prepare jamb flashing by cutting a piece of DuPont™ StraightFlash™ VF at least 6” the inner release paper to form a tight seal in the corner. LONGER than the jamb. E. Remove the inner release paper and adhere the flashing to the back of the brick mold. B. Break the scored release paper on one side of the jamb flashing by folding it back F. At the corner of the window frame, cut the DuPont™ StraightFlash™ VF along the and forth upon itself. corner and fold it down flat to adhere against the head flashing. C. Position so that it contacts the window frame and interior side of the brick mold. Ensure that the jamb flashing is positioned 1-1/2” below the top edge of the head flashing. Jamb flashing adhesive must come in contact with head flashing adhesive and overlap by 1”.

Make sure the adhesive on these 45° pieces will overlap

1” C

E 1-1/2”

A D 45° Window interior

Window interior

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 29 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 6 A. Install window according to manufacturer’s installation instructions. A. Cut a piece of metal or vinyl drip cap slightly longer than the window’s width and B. Apply DuPont™ Adhesive/Primer to exposed sheathing. place a bead of sealant on the rear side. Install the drip cap tight against the window head and cover the top edge with 4” DuPont™ StraightFlash™. C. Remove the remaining release paper from the DuPont™ StraightFlash™ VF jamb ™ ® flashing and press firmly to adhere it to the DuPont™ Tyvek® air and water barrier. B. Flip down upper flap of DuPont Tyvek air and water barrier so it lays flat across head flashing, thentrim 1”-2” above the window opening. D. Remove the release paper at the head and adhere it to the wall surface. C. Tape along all cuts in DuPont™ Tyvek® air and water barrier and tape across drip cap E. OPTIONAL: Cover exposed butyl with DuPont™ StraightFlash™ or DuPont™ Tyvek® Tape. with 3” DuPont™ Tyvek® Tape or 4” DuPont™ StraightFlash™. (See General Instructions for when 3” DuPont™ Tyvek® Tape is allowed.) D. Install DuPont™ Tyvek® Wrap Cap Fasteners over flashing at recommended spacing. Top view Backer rod and sealant NOTE: For high performance designs or areas of extreme exposure use 4” DuPont™ DuPont™ Tyvek® StraightFlash™ to seal the head flap and install additional mechanical fasteners through Brick mold the flashing at the head flap and perimeter of window.

Window Butyl D B B D C A

C

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 30 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 7 STEP 7-A (OPTIONAL ALTERNATE BACK DAM PART 1) Interior View A. While the sealant is still wet, as a best practice, install an “L” shaped back dam cut A. Create a continuous perimeter seal using backer rod and sealant or DuPont™ Window the width of the rough opening so that it contacts the sealant bead and rear of and Door Foam on window interior to resist air and water infiltration. window. Seal by applying recommended sealant along four sides of the exposed back dam. OPTIONAL: Apply sealant along all four sides in lieu of back dam.

Flush with window Towards Towards exterior interior

DuPont™ FlexWrap™ NF sill (side view)

Seal backdam to window with sealant

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 31 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 7-B (OPTIONAL ALTERNATE BACK DAM PART 2) A. Install retention clips around the window to permanently secure it in the rough opening as recommended by window manufacturer to complete installation.

A

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 32 DuPont Self-Adhered Flashing Systems Installation Guidelines

Integral Flanged Window Exterior Exterior Method applies to following products:

™ ™ • DuPont StraightFlash 8“ minimum • DuPont™ FlexWrap™ NF • DuPont™ Flashing Tape B B STEP 1 Prepare DuPont™ Tyvek® air and water barrier for window installation: A. Make an “I-Cut” in the DuPont™ Tyvek® air and water barrier (a modified I-Cut is also acceptable). For an “I-Cut” begin with a horizontal cut across the bottom and the top 8“ of the window frame (for round top windows, the cut should begin 2” above the mull minimum A joint, see D). From the center cut straight down to the sill. B. Cut two 45° degree slits a minimum of 8” from the corner of the header to create a flap above the rough opening to expose sheathing or framing members and to allow head flashing installation (see step 5). Flip head flap up and temporarily secure with DuPont™ Tyvek® Tape. Some windows and flashing widths may require longer slits. C. Fold side flaps into rough opening, cut excess flaps, and secure. NOTE: See pages 61-78 of this guide for alternative flashing options for flanged windows aligned with Section 7 of FMA/AAMA 100-12, Standard Practice for the Installation of Windows with Flanges or Mounting Fins in Wood Framed Construction for Extreme Wind/Water Conditions. D

C

A

Interior

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 33 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 2 A. Cut DuPont™ FlexWrap™ NF at least 12” longer than width of rough opening sill. Center release paper Outer release B. Fold to break perforation. Remove center piece of release paper. Align 6” DuPont™ paper B FlexWrap™ NF with interior edge of sill framing, and adhere into rough opening along sill and up jambs (min 6” on each side). OPTIONAL BACK DAM: Fold 9” DuPont™ FlexWrap™ NF to break perforation. Remove center piece of release paper. Cover horizontal sill leaving 1” of overhang on inside edge of sill for back dam, and adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” overhang of release paper on DuPont™ FlexWrap™ NF inside rough Release paper opening to finish back dam after window installation. for backdam C. Remove second release paper. D. Flex DuPont™ FlexWrap™ NF at bottom corners onto face of wall. Fold to break scores OPTIONAL BACKDAM DETAIL WHEN USING 9” WIDE DUPONT™ FLEXWRAP™ NF

No gap in corner

Window jamb

DuPont™ FlexWrap™ NF

1“ overhang WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

D DO NOT STRETCH Sill length +12

A 6“ minimum

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 34 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 For rectangular windows A. Apply continuous bead of sealant at the window head and jambs to wall or back STEP 4 side of window mounting flange.DO NOT APPLY CONTINUOUS SEALANT A. Install window according to manufacturer’s instructions. BEAD ACROSS BOTTOM SILL FLANGE to allow for drainage. If sealant is applied B. Apply DuPont™ Adhesive/Primer to exposed sheathing. to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for C. Cut two pieces of DuPont™ StraightFlash™, DuPont™ Flashing Tape* or DuPont™ every 4’ of window to allow for drainage. FlexWrap™ NF for jamb flashing extending 1” above window head flange and 4” to 6” below bottom edge of sill flashing. Remove release paper and press tightly along sides of window frame. D. Cut a piece of DuPont™ StraightFlash™, DuPont™ Flashing Tape* or DuPont™ FlexWrap™ NF for head flashing, which extends beyond outer edges of jamb flashings. Remove release paper and install completely covering mounting flange and adhering to exposed sheathing or framing members.

B

A

D

C

C

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 35 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 6 A. Flip down upper flap of DuPont™ Tyvek® air and water barrier so it lays flat across Final Step head flashing, thentrim 1”-2” above the window opening. A. Seal around the window opening at the interior with sealant (and backer rod as B. Tape along all cuts in DuPont™ Tyvek® air and water barrier and tape across head of necessary) or DuPont™ Window and Door Foam. Sealant and backer rod, or foam, the window with 3” DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ will also serve as a back dam. ™ ™ ® StraightFlash . (See General Instructions for when 3” DuPont Tyvek Tape is B. OPTIONAL: If back dam is desired use alternate back dam. Install retention clips allowed.) around the window to permanently secure it in the rough opening as ™ ® C. Install DuPont Tyvek Wrap Cap Fasteners at appropriate spacing at head. recommended by window manufacturer to complete installation. NOTE: For high performance designs or areas of extreme exposure use 4” DuPont™ StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

Flush with window

A Towards Towards exterior interior C

B DuPont™ FlexWrap™ NF sill (side view)

Seal backdam to window with sealant

B

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 36 DuPont Self-Adhered Flashing Systems Installation Guidelines

For roundtop windows (integral flange) STEP 4 STEP 5 A. Apply continuous bead of sealant at the window head and jambs to wall or back side Install head flashing of window mounting flange.DO NOT APPLY CONTINUOUS SEALANT BEAD A. Cut head flashing at least 12” longer than the arc length (H) of round-top window. ACROSS BOTTOM SILL FLANGE to allow for drainage. If sealant is applied to the B. Remove both release and install to conform around top of window, covering sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of entire mounting flange and adhering to exposed sheathing or framing members. window to allow for drainage. Head flashing should overlap jamb flashings at least 6”. B. Apply DuPont™ Adhesive/Primer to the top of the jambs and exposed sheathing. C. Install window according to manufacturer’s instructions. D. Cut two pieces of DuPont™ StraightFlash™, DuPont™ Flashing Tape* or DuPont™ FlexWrap™ NF for jamb flashing extending 1” above window head flange and 4” to 6” below bottom edge of sill B

™ DuPon t

flashing. Remove release

F l e

x

W

r

paper and press tightly along

a

p F F

™ N ™ N N

sides of window frame.

F p p

a a

r r

B

W W

x x

™ ™

t t

e e

n n

l l

o o P

H P

u u

F F

D D

A

6“ minimum

C D

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the D 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 37 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 6 STEP 7 A. Flip down upper flap of DuPont™ Tyvek® air and water barrier so it lays flat across Final Step head flashing, thentrim 1”-2” above the window opening. A. Seal around the window opening at the interior with sealant (and backer rod as B. Tape along all cuts in DuPont™ Tyvek® air and water barrier and across head of the necessary) or DuPont™ Window and Door Foam. Sealant and backer rod, or foam, window with 3” DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ will also serve as a back dam. ™ ™ ® StraightFlash . (See General Instructions for when 3” DuPont Tyvek Tape is B. OPTIONAL: If back dam is desired, flip up 1”use alternate back dam. Install allowed.) retention clips around the window to permanently secure it in the rough opening as ™ ® C. Install DuPont Tyvek Wrap Cap Fasteners at appropriate spacing at head. recommended by window manufacturer to complete installation. NOTE: For high performance designs or areas of extreme exposure use 4” DuPont™ StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

C

A

B Flush with window A Towards Towards exterior interior

DuPont™ FlexWrap™ NF sill (side view)

Seal backdam to window with sealant

B

B

Interior

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 38 DuPont Self-Adhered Flashing Systems Installation Guidelines

Non-Flanged Window Using DuPont™ StraightFlash™ VF Method applies to following products: • DuPont™ StraightFlash™ VF • DuPont™ FlexWrap™ NF

STEP 1 Prepare DuPont™ Tyvek® air and water barrier for window installation. Do not install B. Cut two 45° slits a minimum of 8” from the corner of the header to create a flap fasteners within 6” of the sills and jambs, and within 9” of the head of the openings. above the rough opening to expose sheathing or framing members and to allow head A. Make an “I-Cut” in the DuPont™ Tyvek® air and water barrier (a modified I-Cut is also flashing installation (see step 5). Flip head flap up and temporarily secure with ™ ® acceptable). For an “I-Cut” begin with a horizontal cut across the bottom and the top DuPont Tyvek Tape. Some windows and flashing widths may require longer slits. of the window frame. From the center cut straight down to the sill. C. Fold side flaps into rough opening, cut excess flaps, and secure. Side flaps should cover interior facing framing stud.

Exterior Exterior Interior

8“ minimum

B B

C 8“ minimum A

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 39 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 2 A. Cut DuPont™ FlexWrap™ NF at least 12” longer than width of rough opening sill. Center release paper Outer release B. Fold to break perforation. Remove center piece of release paper. Align 6” DuPont™ paper B FlexWrap™ NF with interior edge of sill framing, and adhere into rough opening along sill and up jambs (min 6” on each side). OPTIONAL BACK DAM: Fold 9” DuPont™ FlexWrap™ NF to break perforation. Remove center piece of release paper. Cover horizontal sill leaving 1” of overhang on inside edge of sill for back dam, and adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” overhang of release paper on DuPont™ FlexWrap™ NF inside rough Release paper opening to finish back dam after window installation. for backdam C. Remove outer release paper. D. Flex DuPont™ FlexWrap™ NF at bottom corners onto face of wall. Fold to break scores OPTIONAL BACKDAM DETAIL WHEN USING 9” WIDE DUPONT™ FLEXWRAP™ NF

No gap in corner

Window jamb

DuPont™ FlexWrap™ NF

1“ overhang WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

D DO NOT STRETCH Sill length +12”

A 6“ Minimum

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 40 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 Scored release paper A. Prepare head flashing by cutting a piece of DuPont™ StraightFlash™ VF at least 12” LONGER than the head length. Before flashing, prime window fins and casings with DuPont™ Adhesive/Primer. B. Break the scored release paper on one side of the head flashing by folding it back and forth upon itself. C. Center the flashing on the window head and position so that it contacts the window frame and interior side of the front flange. Remove the outer release paper and adhere the flashing to the window frame. Use the inner release paper to form a tight DuPont™ StraightFlash™ VF seal in the corner. D. Remove the inner release paper and adhere the flashing to the back of the aluminum Top View window fin and casing. DuPont™ Tyvek® E. At the corner of the window frame, cut the DuPont™ StraightFlash™ VF along the corner at a 45° angle.

F. Fold the DuPont™ StraightFlash™ VF down flat. Window Butyl

A B F D

C

E 45°

Window interior Window interior

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 41 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 4 A. Prepare jamb flashing by cutting a piece of DuPont™ StraightFlash™ VF at least 6” D. Remove the outer release paper and adhere the flashing to the window frame. Use LONGER than the jamb. the inner release paper to form a tight seal in the corner. B. Break the scored release paper on one side of the jamb flashing by folding it back E. Remove the inner release paper and adhere the flashing to the back of the aluminum and forth upon itself. window fin. C. Position the flashing so that it contacts the window frame and interior side of the F. At the corner of the window frame, cut the DuPont™ StraightFlash™ VF along the aluminum window fin. Ensure that the jamb flashing is positioned 1-1/2 inch below corner and fold it down flat to adhere against the head flashing. the top edge of the head flashing. Jamb flashing adhesive must come in contact with G. Cut a 2” x 4” piece of DuPont™ FlexWrap™ NF and patch each corner. head flashing adhesive and overlap by 1”.

Make sure the adhesive on these pieces will overlap 45°

1” G F C

G

E 1-1/2”

A D

Window interior F 45° Window interior

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 42 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 5 – OPTIONAL HIGH PRESSURE SKIRT A. Apply DuPont™ Adhesive/Primer to the top of the jambs and exposed sheathing. A. Create the high pressure skirt by cutting a piece of DuPont™ Tyvek® weather barrier B. Install window according to manufacturer’s installation instructions. If sealant is 1” wider than the width of window opening and approximately 10” in depth. applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead B. Attach skirt to underside of window using a piece of 4” DuPont™ StraightFlash™ cut for every 4’ of window to allow for drainage. to the same width as the skirt. C. Remove the remaining release paper from the DuPont™ StraightFlash™ VF jamb flashing and press firmly to adhere it to the DuPont™ Tyvek® air and water barrier. D. Remove the release paper at the head and adhere it to the wall surface. 4” DuPont™ StraightFlash™ Butyl E. OPTIONAL: Cover exposed butyl with DuPont™ StraightFlash™ or DuPont™ Tyvek® Tape. adhesive

D

B 10”

Peel off release paper and attach to underside of window

C

High pressure skirt (optional – see next step Bend for assembly)

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 43 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 6 STEP 7 A. Cut a piece of metal or vinyl drip cap slightly longer than the window’s width and A. Flip down upper flap of DuPont™ Tyvek® air and water barrier so it lays flat across place a bead of recommended sealant on the rear side. Install the drip cap tight head flashing, thentrim 1”-2” above the window opening. against the window head and cover the top edge with DuPont™ StraightFlash™ or B. Tape along all cuts in DuPont™ Tyvek® air and water barrier and tape across drip cap DuPont™ Tyvek® Tape. with 3” DuPont™ Tyvek® Tape or 4” DuPont™ StraightFlash™. (See General Instructions for when 3” DuPont™ Tyvek® Tape is allowed.) C. Install DuPont™ Tyvek® Wrap Cap Fasteners at jambs and head flap at recommended spacing. NOTE: For high performance designs or areas of extreme exposure use 4” DuPont™ StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

A

A C Top View B DuPont™ Tyvek®

Window Butyl

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 44 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 8 STEP 9 A. Install DuPont™ Tyvek® Wrap Cap Fasteners through the skirt. Final Step B. Secure sides of high pressure skirt to weather barrier with DuPont™ StraightFlash™ A. Seal around the window opening at the interior with sealant (and backer rod as and skip tape bottom with 3” DuPont™ Tyvek® Tape or 4” DuPont™ StraightFlash™. necessary) or DuPont™ Window and Door Foam. Sealant and backer rod, or foam, Skip taping provides weeps that allows drainage behind the skirt. will also serve as a back dam. B. OPTIONAL: If back dam is desired use alternate back dam.

Flush with window Towards Towards exterior interior

DuPont™ FlexWrap™ NF sill (side view)

Seal backdam to window with sealant

A

B

B

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 45 DuPont Self-Adhered Flashing Systems Installation Guidelines

Store front Window on Slab Method applies to following products: • DuPont™ StraightFlash™ • DuPont™ FlexWrap™ NF

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. A. Wrap wall as shown in DuPont™ Tyvek® Mechanically Fastened Air and Water Barrier Installation Guidelines for Buildings Greater Than 4 Stories that can be found at www.weatherization.tyvek.com. Do not install fasteners within 6” of the jambs of the openings and within 9” of the head of the openings.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 46 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 STEP 4 Prepare air and water barrier for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure with tape. A. Cut an opening in the DuPont™ Tyvek® air and water barrier using a square cut around B. Temporarily secure DuPont™ Tyvek® air and water barrier with DuPont™ Tyvek® Tape the perimeter of the rough opening. around rough opening before flashing is installed to help facilitate flashing installation. B. Cuts should be made along the dashed indicated lines. (Ensure that the DuPont™ Tyvek® air and water barrier is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation.

A B

8”

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 47 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 6 A. Prepare the sill flashing per manufacturer’s recommendation and seal the corner pan A. Shim, level and anchor pan per manufacturer’s instructions flashing to flashing with sealant. concrete. B. Inspect installation surface to ensure surface is free of dirt or substances that could B. Seal corner pan flashing seams with sealant. interfere with adhesion as well as any sharp protrusions. OPTION 2: An alternate approved flashing method is to install DuPont™ StraightFlash™ using installation method outlined in “Non-Flanged Window Using DuPont™ StraightFlash™ VF” on page 39.

A

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 48 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 7 STEP 8 A. Wrap 9” DuPont™ StraightFlash™ into the rough opening at each jamb and onto wall A. Apply DuPont™ Adhesive/Primer to the top of the jambs and exposed sheathing. face. The flashing should align with the interior edge of the jamb framing. Cut the jamb flashing the vertical length of the rough opening. B. Jamb flashing should be long enough to overlap the sill flashing by at least 2” and be overlapped by future head flashing by at least 2”.

DuPont™ Adhesive/Primer

2“ minimum overlap

B

A

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 49 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 9 STEP 10 ™ ™ ™ ™ A. Adhere DuPont FlexWrap NF to the head. Make sure the DuPont FlexWrap NF A. Flip down the head flap and trim 1”-2” above the window opening. Terminate flap is cut long enough to overlap the jamb flashing by at least 2”. along the top of the window with 3” DuPont™ Tyvek® Tape or 4” DuPont™ B. Use sufficient width of DuPont™ FlexWrap™ NF to avoid reverse shingling of flashing StraightFlash™. (See General Instructions for when 3” DuPont™ Tyvek® Tape is at the jamb and head interface. See detail below. allowed). B. Apply 4” DuPont™ StraightFlash™ over the diagonal seams. C. Install remaining DuPont™ Tyvek® Wrap Cap Fasteners at head per the recommended spacing (every 12” to 18” depending on the vertical stud line). NOTE: For high performance designs or areas of extreme exposure use 4” DuPont™ StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

B A

A C

INCORRECT CORRECT DuPont™ FlexWrap™ NF DuPont™ StraightFlash™ reverse flashed overlaps DuPont™ FlexWrap™ NF

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 50 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 11 STEP 12 A. Install store front window per manufacturer’s installation instructions. A. Create a continuous perimeter seal using backer rod and sealant or DuPont™ Window B. Glaze windows per manufacturer’s instructions. and Door Foam on window interior to resist air and water infiltration.

A Interior

Exterior Interior

Sealant

Sealant

Backer rod

SIDE VIEW

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 51 DuPont Self-Adhered Flashing Systems Installation Guidelines

Store front Window on Knee Wall Method applies to following products: • DuPont™ StraightFlash™ • DuPont™ FlexWrap™ NF

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically Fastened Air and Water Barrier or slightly below the sill framing to allow for positive drainage. Installation Guidelines for Buildings Greater Than 4 Stories that can be found at www.weatherization.tyvek.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 52 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 STEP 4 Prepare air and water barrier for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure with tape. A. Cut an opening in the DuPont™ Tyvek® air and water barrier using a square cut around B. Temporarily secure DuPont™ Tyvek® air and water barrier with DuPont™ Tyvek® Tape the perimeter of the rough opening. around rough opening before flashing is installed to help facilitate flashing installation. B. Cuts should be made along the dashed indicated lines. (Ensure that the DuPont™ Tyvek® air and water barrier is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation.

A B

8”

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 53 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 6 A. Prepare the sill flashing by cutting a piece of DuPont™ FlexWrap™ NF that is at least A. Install the sill flashing. Remove the largest strip of release paper, align the flashing 12” longer than sill length. Use 6” DuPont™ FlexWrap™ NF for 2” x 4” framing and 9” with the interior edge of sill, and install into rough opening across sill and up jambs DuPont™ FlexWrap™ NF for 2” x 6” framing. (min 6”.) Apply working from the middle of the sill towards the sides. Secure DuPont™ FlexWrap™ NF tightly into the corners by first working in along the sill B. Inspect installation surface to ensure surface is free of dirt or substances that could before adhering up the jambs. interfere with adhesion as well as any sharp protrusions. DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

No gap in corner

Window jamb

DuPont™ FlexWrap™ NF

DO NOT STRETCH WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

Sill length +12” A

A

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 54 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 7 STEP 8 A. Remove second half of the release paper. A. Wrap 9” DuPont™ StraightFlash™ into the rough opening at each jamb and onto wall B. Fan DuPont™ FlexWrap™ NF at bottom corners and adhere onto face of wall. face. The flashing should align with the interior edge of the jamb framing. Cut the jamb flashing the vertical length of the rough opening. C. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles and bubbles by smoothing surface and repositioning as necessary. B. Jamb flashing should be long enough to overlap the sill flashing by at least 2” and be overlapped by future head flashing by at least 2”. D. Shim, level and anchor sill pan flashing and seal corner seams per manufacturer’s instructions with sealant. OPTION 2: An alternate approved flashing method is to install DuPont™ StraightFlash™ using installation method outlined in “Non-Flanged Window Using DuPont™ StraightFlash™ VF” on page 39.

2“ minimum overlap

B

A

B

D

INCORRECT CORRECT DuPont™ FlexWrap™ NF DuPont™ StraightFlash™ reverse flashed overlaps DuPont™ FlexWrap™ NF

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 55 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 9 STEP 10 A. Spray the top of the jambs and exposed sheathing with DuPont™ Adhesive/Primer. A. Adhere DuPont™ FlexWrap™ NF to the head using the same installation process as shown in steps 6 and 7 for the sill flashing. Make sure the DuPont™ FlexWrap™ NF is cut long enough to overlap the jamb flashing by at least 2”.

DuPont™ Adhesive/Primer A

INCORRECT CORRECT DuPont™ FlexWrap™ NF DuPont™ StraightFlash™ reverse flashed overlaps DuPont™ FlexWrap™ NF

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 56 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 11 STEP 12 A. Install storefront window per manufacturer’s installation instructions. A. Flip down the head flap and trim 1”-2” above the window opening. Terminate flap along the top of the window with 3” DuPont™ Tyvek® Tape or 4” DuPont™ B. Glaze windows per manufacturer’s instructions. StraightFlash™. (See General Instructions for when 3” DuPont™ Tyvek® Tape is C. See pages 43-45 if optional skirt flashing is desired. allowed). B. Apply 4” DuPont™ StraightFlash™ over the diagonal seams. C. Install remaining DuPont™ Tyvek® Wrap Cap Fasteners at head per the recommended spacing (every 12” to 18” depending on the vertical stud line). NOTE: For high performance designs or areas of extreme exposure use 4” DuPont™ StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

B A C

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 57 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 13 Interior view A. Create a continuous perimeter seal using backer rod and sealant or DuPont™ Window and Door Foam on window interior to resist air and water infiltration. B. When the facade is complete, place a continuous sealant bead integrating the window to the facade.

Interior

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 58 DuPont Self-Adhered Flashing Systems Installation Guidelines

Alternate Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method A) Method applies to following products: • DuPont™ StraightFlash™ • DuPont™ FlexWrap™ NF • DuPont™ Flashing Tape

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically Fastened Air and Water Barrier or slightly below the sill framing to allow for positive drainage. Installation Guidelines for Buildings Greater Than 4 Stories that can be found at www.weatherization.tyvek.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 59 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 STEP 4 Prepare air and water barrier for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure with tape. A. Cut an opening in the DuPont™ Tyvek® air and water barrier using a square cut around B. Temporarily secure DuPont™ Tyvek® air and water barrier with DuPont™ Tyvek® Tape the perimeter of the rough opening. around rough opening before flashing is installed to help facilitate flashing B. Cuts should be made along the dashed indicated lines. (Ensure that the DuPont™ installation. Tyvek® air and water barrier is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation.

8“

A

B 8“

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 60 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 6 A. Prepare the sill flashing by cutting a piece of DuPont™ FlexWrap™ NF that is at least A. Install the sill flashing. Remove the largest strip of release paper, align the flashing 12” longer than sill length. Use 6” DuPont™ FlexWrap™ NF for 2” x 4” framing and 9” with the interior edge of sill, and install into rough opening across sill and up jambs DuPont™ FlexWrap™ NF for 2” x 6” framing. (min 6”). Apply working from the middle of the sill towards the sides. Secure DuPont™ FlexWrap™ NF tightly into the corners by first working in along the sill B. Inspect installation surface to ensure surface is free of dirt or substances that could before adhering up the jambs. interfere with adhesion as well as any sharp protrusions. B. Cover holes in studs with patches of DuPont™ self-adhered flashing product. DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

Center release paper Outer release paper

B Release paper for backdam DO NOT STRETCH

B A Fold to break scores OPTIONAL BACKDAM DETAIL WHEN USING 9” WIDE DUPONT™ FLEXWRAP™ NF 6” A

Sill length +12” No gap in corner

Window jamb

DuPont™ FlexWrap™ NF

WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 61 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 7 STEP 8 A. Remove second half of the release paper. A. Install 4” DuPont™ StraightFlash™ into the rough opening at each jamb and onto wall B. Fan DuPont™ FlexWrap™ NF at bottom corners and adhere onto face of wall. face. The flashing does not need to align with the interior edge of the jamb framing. Cut the jamb flashing the vertical length of the rough opening. C. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles and bubbles by smoothing surface and repositioning as necessary. B. Jamb flashing should be long enough to overlap the sill flashing by at least 2” and be overlapped by future head flashing by at least 2”. C. Apply sealant to inside corners of rough opening at jamb/head.

2“ minimum overlap C

B

A

INCORRECT CORRECT DuPont™ FlexWrap™ NF DuPont™ StraightFlash™ reverse flashed overlaps DuPont™ FlexWrap™ NF

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 62 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 9 STEP 10 A. Apply continuous bead of sealant at the window head and jambs to wall or back A. Install window according to manufacturer’s instructions. side of window mounting flange. B. Apply DuPont™ Adhesive/Primer to exposed sheathing. DO NOT APPLY CONTINUOUS SEALANT BEAD ACROSS BOTTOM SILL C. Cut two pieces of DuPont™ StraightFlash™, DuPont™ Flashing Tape* or DuPont™ FLANGE to allow for drainage. If sealant is applied to the sill, ensure that there are FlexWrap™ NF for jamb flashing extending 1” above window head flange and 4” to at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow for 6” below bottom edge of sill flashing. Remove release paper and press tightly along drainage. sides of window frame. D. Cut a piece of DuPont™ StraightFlash™, DuPont™ Flashing Tape* or DuPont™ FlexWrap™ NF for head flashing, which extends beyond outer edges of jamb flashings. Remove release paper and install completely covering mounting flange and adhering to exposed sheathing or framing members.

B

A

D

C

C

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 63 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 11 STEP 12 A. Flip down upper flap of DuPont™ Tyvek® air and water barrier so it lays flat across Final Step head flashing, thentrim 1”-2” above the window opening. A. Seal around the window opening at the interior with sealant (and backer rod as B. Tape along all cuts in DuPont™ Tyvek® air and water barrier and tape across head of necessary) or DuPont™ Window and Door Foam. Sealant and backer rod, or foam, the window with 3” DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ will also serve as a back dam. ™ ™ ® StraightFlash . (See General Instructions for when 3” DuPont Tyvek Tape is B. OPTIONAL: If back dam is desired use alternate back dam. Install retention clips allowed.) around the window to permanently secure it in the rough opening as ™ ® C. Install DuPont Tyvek Wrap Cap Fasteners at appropriate spacing at head. recommended by window manufacturer to complete installation. NOTE: For high performance designs or areas of extreme exposure use 4” DuPont™ StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

Flush with window Towards Towards exterior interior A C DuPont™ FlexWrap™ NF sill (side view) B

Seal backdam to window with sealant

B

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 64 DuPont Self-Adhered Flashing Systems Installation Guidelines

Alternate Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method B) Method applies to following products: • DuPont™ StraightFlash™ • DuPont™ FlexWrap™ NF • DuPont™ Flashing Tape

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically Fastened Air and Water Barrier or slightly below the sill framing to allow for positive drainage. Installation Guidelines for Buildings Greater Than 4 Stories that can be found at www.weatherization.tyvek.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 65 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 STEP 4 Prepare air and water barrier for window installation. A. Cut two 45° slits extending from the bottom corner up and away from the window A. Cut an opening in the DuPont™ Tyvek® air and water barrier using a square cut around opening to expose approximately 8” of sheathing. This will create a flap at each jamb the perimeter of the rough opening. to allow for jamb flashing installation. B. Cuts should be made along the dashed indicated lines. (Ensure that the DuPont™ B. Flip the flaps to the side to expose the sheathing and temporarily secure with ™ ® Tyvek® air and water barrier is cut flush with the sheathing and is not wrapped into DuPont Tyvek Tape. the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation. D. Flip the head flap up to expose the sheathing and temporarily secure with DuPont™ Tyvek® Tape.

8“

C D

A 8“

B

B

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 66 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 6 A. Apply DuPont™ Adhesive/Primer to exposed sheathing at jambs and head. A. Install the sill flashing. Remove the largest strip of release paper, align the flashing B. Prepare the sill flashing by cutting a piece of DuPont™ FlexWrap™ NF that is at least with the interior edge of sill, and install into rough opening across sill and up jambs (min 6”). Apply working from the middle of the sill towards the sides. Secure 12” longer than sill length. Use 6” DuPont™ FlexWrap™ NF for 2” x 4” framing and 9” DuPont™ FlexWrap™ NF tightly into the corners by first working in along the sill DuPont™ FlexWrap™ NF for 2” x 6” framing. before adhering up the jambs. C. Inspect installation surface to ensure surface is free of dirt or substances that could B. Cover holes in studs with patches of DuPont™ self-adhered flashing product. interfere with adhesion as well as any sharp protrusions. DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

Center release paper Outer release paper B

B Release paper for backdam A DO NOT STRETCH

Fold to break scores C OPTIONAL BACKDAM DETAIL WHEN USING B ™ ™ 6” 9” WIDE DUPONT FLEXWRAP NF

No gap in corner Sill length +12” Window jamb

DuPont™ FlexWrap™ NF

WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 67 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 7 STEP 8 A. Remove second half of the release paper. A. Apply continuous bead of sealant at the window head and jambs to wall or back B. Fan DuPont™ FlexWrap™ NF at bottom corners and adhere onto face of wall. side of window mounting flange. DO NOT APPLY CONTINUOUS SEALANT BEAD ACROSS BOTTOM SILL C. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles FLANGE to allow for drainage. If sealant is applied to the sill, ensure that there are and bubbles by smoothing surface and repositioning as necessary. at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow for drainage.

A

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 68 DuPont Self-Adhered Flashing Systems Installation Guidelines

For rectangular windows STEP 10 STEP 9 A. Flip over flaps of DuPont™ Tyvek® air and water barrier so each lays flat across jamb A. Install window according to manufacturer’s instructions. flashing, thentrim 1”-2” from the window opening using shears so as not to B. Cut two pieces of DuPont™ StraightFlash™, DuPont™ Flashing Tape* or DuPont™ damage the DuPont™ StraightFlash™ below. FlexWrap™ NF for jamb flashing extending 1” above window head flange and 4” to B. Starting at the bottom of the window, install DuPont™ Flashing Tape* or 4” DuPont™ 6” below bottom edge of sill flashing. Remove release paper and press tightly along StraightFlash™ along the angled cut in in the DuPont™ Tyvek® air and water barrier. sides of window frame. (See General Instructions for when 3” DuPont™ Tyvek® Tape is allowed.) C. Cut a piece of DuPont™ StraightFlash™, DuPont™ Flashing Tape* or DuPont™ C. Install DuPont™ Flashing Tape* or 4” DuPont™ StraightFlash™ along the jamb flaps. ™ FlexWrap NF for head flashing, which extends beyond outer edges of jamb Repeat on other side of window. flashings. Remove release paper and install completely covering mounting flange and ™ adhering to exposed sheathing or framing members. NOTE: For high performance designs or areas of extreme exposure use 4” DuPont StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the jamb flap and perimeter of window.

C C

A

B B

B

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 69 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 11 STEP 12 A. Flip down upper flap of DuPont™ Tyvek® air and water barrier so it lays flat across Final Step head flashing, thentrim 1”-2” above the window opening. A. Seal around the window opening at the interior with sealant (and backer rod as B. Tape along all cuts in DuPont™ Tyvek® air and water barrier and tape across head of necessary) or DuPont™ Window and Door Foam. Sealant and backer rod, or foam, the window with 3” DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ will also serve as a back dam. ™ ™ ® StraightFlash . (See General Instructions for when 3” DuPont Tyvek Tape is B. OPTIONAL: If back dam is desired use alternate back dam. Install retention clips allowed.) around the window to permanently secure it in the rough opening as ™ ® C. Install DuPont Tyvek Wrap Cap Fasteners at appropriate spacing at head. recommended by window manufacturer to complete installation. NOTE: For high performance designs or areas of extreme exposure use 4” DuPont™ StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

Flush with window Towards Towards exterior interior A B DuPont™ FlexWrap™ NF sill (side view)

Seal backdam to C window with sealant

B

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 70 DuPont Self-Adhered Flashing Systems Installation Guidelines

Alternate Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method C) Method applies to following products: • DuPont™ StraightFlash™ • DuPont™ FlexWrap™ NF • DuPont™ Flashing Tape

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically Fastened Air and Water Barrier or slightly below the sill framing to allow for positive drainage. Installation Guidelines for Buildings Greater Than 4 Stories that can be found at www.weatherization.tyvek.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 71 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 3 STEP 4 Prepare air and water barrier for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure with DuPont™ ® A. Make an “I-Cut” in the DuPont™ Tyvek® air and water barrier. For an “I-Cut” begin Tyvek Tape. with a horizontal cut across the bottom and the top of the window frame (for round B. Flip the flaps to the side to expose the sheathing and temporarily secure with top windows, cut from the center cut straight down to the sill. DuPont™ Tyvek® Tape. B. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation. C. Cut two 45° slits extending from the bottom corner up and away from the window opening to expose 6”-8” of sheathing. This will create a flap at each jamb to allow for jamb flashing installation.

8“ minimum

A

B

8“ minimum A

B

C

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 72 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 5 STEP 6 A. Prepare the sill flashing by cutting a piece of DuPont™ FlexWrap™ NF that is at least A. Install the sill flashing. Remove the largest strip of release paper, align the flashing 12” longer than sill length. Use 6” DuPont™ FlexWrap™ NF for 2” x 4” framing and 9” with the interior edge of sill, and install into rough opening across sill and up jambs DuPont™ FlexWrap™ NF for 2” x 6” framing. (min 6”). Apply working from the middle of the sill towards the sides. Secure DuPont™ FlexWrap™ NF tightly into the corners by first working in along the sill B. Inspect installation surface to ensure surface is free of dirt or substances that could before adhering up the jambs. interfere with adhesion as well as any sharp protrusions. C. Starting at the bottom corner, apply DuPont™ Adhesive/Primer to exposed sheathing DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS. at least 6” up the jamb. Center release paper Outer release paper B

Release paper for backdam

C Fold to break scores DO NOT OPTIONAL BACKDAM DETAIL WHEN USING B STRETCH 9” WIDE DUPONT™ FLEXWRAP™ NF A

6” Sill length +12”

No gap in corner

Window jamb

DuPont™ FlexWrap™ NF

WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 73 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 7 STEP 8 A. Remove second half of the release paper. A. Fold side flaps into rough opening, cut excess flaps, and secure secure with 3” ™ ® ™ ™ ™ B. Fan DuPont™ FlexWrap™ NF at bottom corners and adhere onto face of wall. DuPont Tyvek Tape, DuPont Flashing Tape* or 4” DuPont StraightFlash . C. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles and bubbles by smoothing surface and repositioning as necessary. D. Apply continuous bead of sealant to wall at the window jambs.

Interior

D

B

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 74 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 9 STEP 10 A. Starting at the bottom of the window, install DuPont™ Flashing Tape* or 4” A. Install window according to manufacturer’s instructions. ™ ™ ™ ® DuPont StraightFlash along the angled cut in in the DuPont Tyvek air and B. Apply DuPont™ Adhesive/Primer to exposed sheathing at jambs and head. water barrier. (See General Instructions for when 3” DuPont™ Tyvek® Tape is C. Cut two pieces of DuPont™ StraightFlash™, DuPont™ Flashing Tape* or DuPont™ allowed.) FlexWrap™ NF for jamb flashing extending 1” above window head flange and 4” to B. Apply continuous bead of sealant at the window head and jambs to wall or back 6” below bottom edge of sill flashing. Remove release paper and press tightly along side of window mounting flange.DO NOT APPLY CONTINUOUS SEALANT sides of window frame. BEAD ACROSS BOTTOM SILL FLANGE to allow for drainage. If sealant is applied D. Cut a piece of DuPont™ StraightFlash™, DuPont™ Flashing Tape* or DuPont™ to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for FlexWrap™ NF for head flashing, which extends beyond outer edges of jamb every 4’ of window to allow for drainage. flashings. Remove release paper and install completely covering mounting flange and adhering to exposed sheathing or framing members.

B

D

C

C

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 75 DuPont Self-Adhered Flashing Systems Installation Guidelines

STEP 11 STEP 12 A. Flip down upper flap of DuPont™ Tyvek® air and water barrier so it lays flat across Final Step head flashing, thentrim 1”-2” above the window opening. A. Seal around the window opening at the interior with sealant (and backer rod as B. Tape along all cuts in DuPont™ Tyvek® air and water barrier and tape across head of necessary) or DuPont™ Window and Door Foam. Sealant and backer rod, or foam, the window with 3” DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ will also serve as a back dam. ™ ™ ® StraightFlash . (See General Instructions for when 3” DuPont Tyvek Tape is B. OPTIONAL: If back dam is desired use alternate back dam. Install retention clips allowed.) around the window to permanently secure it in the rough opening as ™ ® C. Install DuPont Tyvek Wrap Cap Fasteners at appropriate spacing at head. recommended by window manufacturer to complete installation. NOTE: For high performance designs or areas of extreme exposure use 4” DuPont™ StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

Flush with window Towards Towards exterior interior A C DuPont™ FlexWrap™ NF sill (side view) B

Seal backdam to window with sealant

B

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 76 DuPont Self-Adhered Flashing Systems Installation Guidelines

Installation Instructions for Through Wall Flashing Shelf angle ™ ® Through Wall Flashing – DuPont Tyvek Interface A. Through wall flashing should be applied to the top of the shelf angle and the DuPont™ Base of wall Tyvek® air and water barrier should be properly shingled over by at least 6”. A. Install through wall flashing on the vertical wall per plans and specifications. The B. Seal the DuPont™ Tyvek® air and water barrier to the bottom of the shelf angle using through wall flashing may be terminated by using a reglet, counterflashing, DuPont™ self-adhered flashing products. termination bar or by embedding in a mortar joint. C. Seal bottom of the DuPont™ Tyvek® air and water barrier to through wall flashing using B. Overlap through wall flashing with DuPont™ Tyvek® air and water barrier by 6”. 3” DuPont™ Tyvek® Tape or a DuPont™ self-adhered flashing product. C. Mechanically fasten bottom of air and water barrier through top of through wall flashing. D. Seal vertical and horizontal seams using 3” DuPont™ Tyvek® Tape or DuPont™ self-adhered flashing products. NOTE: For high performance designs or areas of extreme exposure install additional mechanical fasteners through the DuPont™ Tyvek® air and water barrier terminated at the base of the wall. Use appropriate fastener for each substrate.

6”

C 6”

D B A 6” Through wall C B flashing Seal bottom using A a minimum 3" (75mm) width Lap DuPont™ Tyvek® DuPont™ Tyvek® Tape Tape or 6” (150mm) over a DuPont™ self-adhered through wall flashing flashing product Seal to shelf angle using a DuPont™ self-adhered flashing product

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 77 DuPont Self-Adhered Flashing Systems Installation Guidelines

Parapet wall with brick A. Apply DuPont™ Adhesive/Primer to wall surface or sheathing and install a minimum 4” DuPont™ StraightFlash™. B. Install roofing membrane C. Install through wall flashing over parapet wall, overlapping the DuPont™ Tyvek® air and water barrier and the roofing membrane by a minimum of 4” in the proper shingling manner. D. Install DuPont™ StraightFlash™ or DuPont™ Flashing Tape patches behind brick tie base plate. E. Install coping cap. NOTE: Additional CAD details are available in the Technical Information section of www.weatherization.tyvek.com.

E C

B

A

4” D

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 78 DuPont Self-Adhered Flashing Systems Installation Guidelines

Penetrations Seal around plumbing pipes, HVAC components, electrical outlets, exterior lights, flashing panels, and other objects that penetrate the DuPont™ Tyvek® air and water barrier. Always use positive shingling by installing DuPont™ Tyvek® air and water barriers and self adhered flashing products from bottom to top, with upper layer installed over lower layer. OPTIONAL LAST STEP FOR ALL INSTALLATIONS: Install a piece of DuPont™ Tyvek® air and water barrier and seal with DuPont™ Tyvek® Tape to overlap the top edge of the DuPont™ Self-Adhered Flashing product (shown below). Flashing Integral Flanged Products AFTER Installation of DuPont™ Tyvek® Air and Water Barrier

STEP 1 STEP 2 STEP 3 STEP 4 (OPTIONAL) Install DuPont™ Tyvek® air and water Install integral flanged product per Install DuPont™ StraightFlash™ or DuPont™ Install a piece of DuPont™ Tyvek® air and barrier and cut as necessary to manufacturer’s instructions. Flashing Tape* onto flanges, extending water barrier to overlap the top edge of accommodate integral flanged product. onto DuPont™ Tyvek® air and water barrier the DuPont™ StraightFlash™. Seal sides by a minimum of 2”. and top with DuPont™ Tyvek® Tape

*DuPont™ Flashing Tape is only permitted for Residential- Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 79 DuPont Self-Adhered Flashing Systems Installation Guidelines

Option 1: Flashing Non-Flanged For non-flanged products with OD GREATER than 2” ™ AFTER Installation of DuPont STEP 1 STEP 2 ® Tyvek Air and Water Barrier Using Install DuPont™ Tyvek® air and water Cut a piece of DuPont™ FlexWrap™ EZ ™ ™ DuPont FlexWrap EZ barrier over non-flanged product and cut longer than circumference of non-flanged around penetration. product to ensure a minimum 1” overlap ™ ® Use DuPont™ FlexWrap™ EZ only when onto the DuPont Tyvek air and water penetration rough opening (RO) is not barrier. Starting at the horizontal position more than ½“ larger than the outside on either side, adhere around penetration ™ ® diameter/dimension (OD) of non- and onto DuPont Tyvek air and water flanged product. barrier.

RO

OD ™ t n o P u D Start

N

O I

T C E IR D P A 1” R W

For non-flanged products with OD LESS than 2” STEP 1 STEP 2 STEP 3 Install DuPont™ Tyvek® air and water Cut a piece of DuPont™ FlexWrap™ EZ the Cut a second piece of DuPont™ barrier over non-flanged product and cut length of ½ the circumference of the FlexWrap™ EZ the length of the pipe around penetration. non-flanged product. Adhere onto bottom circumference. Adhere onto top section section and fan out onto DuPont™ Tyvek® and fan out onto face of wall with a air and water barrier. minimum of 1” overlap of the edges of DuPont™ FlexWrap™ EZ below.

1” 1”

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 80 DuPont Self-Adhered Flashing Systems Installation Guidelines

Option 2: Flashing Non-Flanged Products AFTER Installation of DuPont™ Tyvek® Air and Water Barrier Using DuPont™ FlexWrap™ NF STEP 1 STEP 2 Install DuPont™ Tyvek® air and water Working counterclockwise, install barrier over non-flanged product and cut DuPont™ FlexWrap™ NF around around penetration. penetration with a minimum 2” overlap.

F

™ N p a r

W

x

t

e

n

l

o

P

u

F D

2”

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 81 DuPont Self-Adhered Flashing Systems Installation Guidelines

Flashing Integral Flanged Products BEFORE Installation of DuPont™ Tyvek® Air and Water Barrier

STEP 1 STEP 2 STEP 3 Install integral flanged product onto Prime as necessary with DuPont™ Install DuPont™ Tyvek® air and water barrier. sheathing per manufacturer’s instructions. Adhesive/Primer. Install DuPont™ StraightFlash™ or DuPont™ Flashing Tape* onto flanges, extending onto sheathing by a minimum of 2”.

2” ✃

STEP 4 STEP 5 ™ ™ ® ™ ® *DuPont Flashing Tape is only permitted for Residential- Make cut in DuPont Tyvek air and water Seal edges of DuPont Tyvek air and Use building structures. Residential-Use (Group R) is ™ ™ barrier, ensuring a minimum of 2” gap for water barrier with DuPont StraightFlash . defined by the 2015/2018 International Building Code. adhesion of DuPont™ StraightFlash™.

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 82 DuPont Self-Adhered Flashing Systems Installation Guidelines

Proper overlap for water management NOTE: In order to make a claim under the DuPont Weatherization Products 10-Year Limited Product and Labor Warranty, you must have met all of the terms and conditions of the warranty, including use of the applicable DuPont Installation Guidelines. In the event that a specific detail or installation technique is not covered in the DuPont Installation Guidelines at the time you are building, then the Key Installation Requirements outlined in this document must have been followed in order to make a claim under the warranty. Compliance prior, during and post construction with the Key Installation Requirements are at the sole discretion of DuPont. Please contact DuPont or a DuPont™ Tyvek® Specialist if you have any questions in connection with any DuPont Installation Guideline.

INCORRECT CORRECT DuPont™ FlexWrap™ NF DuPont™ StraightFlash™ reverse flashed overlaps DuPont™ FlexWrap™ NF

Copyright ©2018 E. I. du Pont de Nemours and Company. All Rights Reserved. K-17976 Rev. 6/18 83 Technical Specifications Note ™ DuPont™ Tyvek® air and water barriers used in construction products are made from 100% flash When installed in conjunction with other building materials, DuPont self-adhered flashing products spunbonded high density polyethylene fibers which have been bonded together by heat and must be properly shingled with these materials such that water is diverted to the exterior of the ™ ® pressure, without binders or fillers, into a tough durable sheet structure. Additives have been wall system. DuPont Tyvek products are air and water barriers and not the primary water barrier. incorporated into the polyethylene to provide ultraviolet light resistance. DuPont requires that The outer facade is the primary barrier. You must follow facade manufacturer’s installation and DuPont™ Tyvek® CommercialWrap® and CommercialWrap® D be covered within nine months maintenance requirements for all facade systems in order to maintain water holdout properties and ™ ® (270 days) of installation. ensure performance of DuPont Tyvek air and water barriers. Use of additives, coatings or cleansers on or in the facade system may impact the performance of DuPont™ Tyvek® air and DuPont™ self-adhered flashing products are made from a synthetic rubber adhesive and a laminate water barriers. DuPont™ Tyvek® Weatherization Systems products are to be used as outlined in this of polyethylene film, polypropelene film, elastic fiber, synthetic rubber adhesive, polyurethane installation guideline. DuPont™ self-adhered flashing products should only be used to seal adhesive, and a top sheet of flash spunbonded high density polyethylene fibers or polypropelene penetrations and flash openings in houses or buildings. DuPont™ self-adhered flashing products are film. Additives have been incorporated into these materials to provide ultraviolet light resistance. not to be used in roofing applications. For superior protection against bulk water penetration, DuPont requires that DuPont™ FlexWrap™ EZ, FlexWrap™ NF, StraightFlash™ and StraightFlash™ VF DuPont suggests a system combining a quality exterior facade, a good secondary air and water be covered within nine months (270 days) of installation. DuPont requires that DuPont™ Flashing barrier and exterior sheathing, high quality windows and doors, and appropriate flashing materials Tape be covered within four months (120 days) of installation. paying attention to proper installation of each component. In a system where no exterior sheathing is used and DuPont™ Tyvek® air and water barrier is installed directly over the wall studs, exterior Warning facade materials should be selected to ensure maximum protection against water intrusion. Careful ™ ® DuPont Tyvek air and water barriers are slippery and should not be used in any workmanship and proper installation of each component is very important. application where they will be walked on. In addition, because they are slippery, DuPont recommends using kickjacks, scaffolding, or lifts for exterior work above the first floor. If DuPont believes this information to be reliable and accurate. The information may be subject to ladders must be used, extra caution must be taken to use them safely by following the revision as additional experience and knowledge is gained. It is the user’s responsibility to determine requirements set forth in ANSI Standards 14.1, 14.2, and 14.5 for ladders made of wood, the proper construction materials needed. aluminum, and fiberglass, respectively. DuPont™ Tyvek® is combustible and should be protected from flames and other high heat sources. DuPont™ Tyvek® will melt at 275°F For complete warranty information please call 1-800-44-Tyvek. (135°C) and if the temperature of DuPont™ Tyvek® reaches 750°F (400°C), it will burn and the This information is not intended to be used by others for advertising, promotion, or other fire may spread and fall away from the point of ignition. For more information, call publication for commercial purposes. 1-800-44-Tyvek.

DuPont™ self-adhered flashing products and their release paper are slippery and should not be walked on. Remove release paper from work area immediately. DuPont™ Flashing Systems products will melt at temperatures greater than 250°F (121°C). DuPont™ Flashing Systems products are combustible and should be protected from flames and other high heat sources. DuPont™ Flashing Systems products will not support combustion if the heat source is removed. However, if burning occurs, ignited droplets may fall away from the point of ignition. For more information, call 1-800-44-Tyvek. For more information about DuPont Weatherization Systems, please call 1-800-44-Tyvek or visit us at www.weatherization.tyvek.com

Copyright © 2018 E. I. du Pont de Nemours and Company. The DuPont Oval Logo, DuPont™, Tyvek®, CommercialWrap®, FlexWrap™, and StraightFlash™ are registered trademarks or trademarks of DuPont or its affiliates. All rights reserved. K-17976 6/18