DuPont Performance Building Solutions

DuPont Self-Adhered Flashing Products Installation Guidelines

For Buildings Greater than 4 Stories and High-Performance Installations of Any Height

July 2020 Table of Contents Applicable Products...... 3 Brick Mold Window...... 71

Required Materials Based on Project Requirements, Details, Non-Flanged Window Using DuPont™ VersaFlange™...... 78 and Specifications...... 3 Installation Method for Installing DuPont Self-Adhered Flashing Products Note ...... 3 BEFORE DuPont™ ® WRB...... 86

Warranty...... 3 Non-Flanged or Integral Flanged Window...... 86

Special Considerations...... 4 Hybrid Condition – DuPont™ Tyvek® WRB Terminated with DuPont™ StraightFlash™ and/or DuPont™ FlexWrap™ and Integrated Key Installation Requirements for Drainable Window / Door Installation...... 6 with DuPont™ Tyvek® Fluid Applied Products...... 89

Installation Methods for DuPont Self-Adhered Flashing Products Installation Methods for DuPont™ Tyvek® WRB Interfaces with AFTER the DuPont™ Tyvek® WRB is Installed...... 7 Through Wall Flashing...... 93

Non-Flanged Window...... 7 Penetrations...... 95

Non-Flanged Window with Floating Lintel and Brick Facade...... 14 Product Composition and UV Stability...... 98

Non-Flanged Door on Slab...... 25 Design Considerations...... 98

Storefront Window on Slab...... 33 Safety and Handling ...... 98

Storefront Window on Knee Wall...... 39 Hazard Statement...... 99

Integral Flanged Window...... 46

Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method A)...... 53

Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method B)...... 59

Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method C)...... 65

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 2 Applicable Products Required Materials Based on Project Requirements, Details, 1 Mechanically-Fastened Water-Resistive and Air Barriers (Tyvek® WRBs) and Specifications Product Dimensions Area • Backer Rod 2 DuPont™ Tyvek® CommercialWrap® 5 ft x 200 ft 1,000 sq ft • Sealant 10 ft x 125 ft 1,250 sq ft • Brushes for Surface Preparation DuPont™ Tyvek® CommercialWrap® D 5 ft x 200 ft 1,000 sq ft • J-Roller 10 ft x 125 ft 1,250 sq ft • Trowels Self-Adhered Flashing Products • Rodenhouse Grip-Deck® screws with Thermal-Grip FastCap™ washers3 1Apply per manufacturers’ guidelines. For non DuPont products, DuPont assumes no liability in use of Product Width recommended products; installers need to evaluate suitability of recommended products in their end-use DuPont™ FlexWrap™ (Formerly DuPont™ FlexWrap™ NF) 6 in applications. 9 in 2For information regarding chemically compatibility of sealants, see technical bulletin Chemical Compatibility of Representative Building Sealants and /Primers. DuPont™ FlexWrap™ EZ 2.75 in 3For information regarding installation of Rodenhouse fasteners, refer to the DuPont™ Tyvek® Mechanically- DuPont™ StraightFlash™ 4 in Fastened Water-Resistive and Air Barriers (WRB) Installation Guidelines for Buildings Greater than 4 Stories 9 in and High Performance Installations of Any Height. DuPont™ VersaFlange™ (Formerly DuPont™ StraightFlash™ VF) 6 in Note ™ DuPont Flashing Tape 4 in This installation guideline outlines recommended installation techniques and details 6 in for DuPont Self-Adhered Flashing Products and where applicable, DuPont™ Tyvek® 9 in ® ® ® ™ ® 12 in CommercialWrap , Tyvek CommercialWrap D, and/or DuPont Tyvek Fluid Applied Products. Both Tyvek® WRBs and Tyvek® Fluid Applied Products meet or exceed Fluid Applied Products the requirements of a water-resistive barrier as defined in the 2018 International ® Product Quantity Residential Code (IRC) and the 2018 International Building Code (IBC). Tyvek CommercialWrap®, Tyvek® CommercialWrap® D and Tyvek® Fluid Applied Products DuPont™ Tyvek® Fluid Applied WB+™ 5 gal, 50 gal also function as a high performance air barrier and pass ASTM E2357. DuPont™ Tyvek® Fluid Applied Flashing and Joint Compound+ 28 oz, 3.5 gal DuPont™ Sealant for Tyvek® Fluid Applied* 28 oz Warranty *DuPont™ Sealant for Tyvek® Fluid Applied System should only be used as directed in the applicable DuPont™ Please refer to the DuPont Building Solutions Products 10-Year Limited Tyvek® Fluid Applied Products Installation Guidelines. Warranty for Buildings Greater Than 4 Stories. For buildings less than 5 stories, and Installation Accessories low-rise multi-family buildings less than 6 stories, please refer to the DuPont Building Product Type Quantity Envelope Solutions Products 10-Year Limited Warranty for Buildings Less Than 5 Stories DuPont™ /Primer Can 13.5 oz and Low-Rise Multi-Family Residential Buildings Less Than 6 Stories. DuPont™ Tyvek® Tape 3” Bulk Pack 24 rolls/ NOTE: In order to make a claim under the DuPont 10-Year Limited Product and Labor DuPont™ Tyvek® Wrap Cap Screws 2” dia. cap, 1-3/4” Warranty on DuPont Building Envelope Solutions Products, all terms and conditions of 1,000 caps/ screw length the warranty must be met, including use of the applicable DuPont Installation Guidelines Great Stuff Pro™ Window & Door Can (reusable dispensing available at the date of original installation. In the event that a specific detail or 20 oz Polyurethane Foam Sealant gun sold separately) installation technique is not covered in the DuPont Installation Guidelines at the time of Great Stuff Pro™ Gaps & Cracks Can (reusable dispensing construction, then the Key Installation Requirements must have been followed in order 20 oz Polyurethane Foam Sealant gun sold separately) to make a claim under the warranty. Compliance prior, during and post construction with the Key Installation Requirements are at the sole discretion of DuPont. Please contact DuPont or a DuPont™ Tyvek® Specialist if you have any questions in connection with any DuPont Installation Guideline.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 3 Special Considerations 1. DuPont Self-Adhered Flashing Products should be installed on clean, dry surfaces recommended foam, extends beyond the window frame, shave the excess cured foam that are free of frost. Wipe surfaces to remove moisture, dirt, grease and other flush with the window frame before applying sealant. Avoid damaging the DuPont Self- debris that could interfere with adhesion. Adhered Flashing, DuPont™ Tyvek® Fluid Applied Products or DuPont™ Tyvek® WRB. 2. DuPont Self-Adhered Flashing Products perform best when installed at 12. For extreme/coastal exposures installation of a high-pressure skirt is temperatures above 25°F ( -4°C). recommended to help prevent water intrusion at the sill or threshold. 3. Adverse weather conditions or cold temperatures may require use of a primer to 13. For high pressure design loads, the use of DuPont™ StraightFlash™ with DuPont™ promote adhesion of DuPont Self-Adhered Flashing Products to most common Tyvek® Wrap Cap Fasteners, or recommended fasteners is required to secure the building materials. Concrete, masonry, and fiber-faced exterior gypsum board head flap of the windows. ™ require the use of DuPont Adhesive/Primer or recommended primer. 14. Before applying 3” DuPont™ Tyvek® Tape, surfaces should be dry and clean. 4. Apply pressure along entire surface of flashing for a good bond using firm hand During installation apply firm, even pressure with hand or “J” roller. pressure, J-roller, or alternate without sharp edges (such as a plastic carpet tuck 15. In lieu of temporarily taping, Tyvek® WRB flaps at window head and jambs can be tool) to assist with application of uniform pressure during installation of DuPont tucked under the installed Tyvek® WRB. Self-Adhered Flashing Products. 16. 4” DuPont™ Flashing Tape is an alternative to 3” Tyvek® Tape where specified 5. Remove all wrinkles and bubbles by smoothing surface and repositioning as in the DuPont™ Tyvek® Mechanically Fastened Water-Resistive and Air Barrier necessary. (WRB) Installation Guidelines for Buildings Greater Than 4 Stories and High 6. DuPont Self-Adhered Flashing Products are not intended for through-wall flashing Performance Installations of Any Height. applications. 17. 3” Tyvek® Tape should not be used to terminate Tyvek® WRB flaps at window 7. When flashing the sill area for windows and doors, DuPont recommends the use jambs and head when the building envelope design requirements exceed ASTM of 6” wide DuPont™ FlexWrap™ for 2”x 4” framing and 9” wide FlexWrap™ for 2” x 6” E1677, 65 mph equivalent structural load and 15 mph equivalent wind-driven framing. When rigid back dams are required or desired, an option would be to use rainwater infiltration resistance. a ¾” corner guard (back dam) cut to the length of the sill and nail into place on the 18. Door and window rough sill framing must be level or slightly sloped to the ™ interior edge of the sill prior to installation of 9” wide FlexWrap . Then install 9” exterior to ensure proper drainage to the exterior. This best practice ensures ™ wide FlexWrap over sill and corner guard back dam. continuous support with positive slope to the exterior. ™ ™ 8. DO NOT STRETCH FlexWrap when installing along sills or jambs. FlexWrap is only 19. For window or door openings greater than 6 feet wide (commercial installations intended to be stretched when covering corners or curved sections. only): A 3-piece sill and head detail is allowed using StraightFlash™ and 9. Avoid placing DuPont™ Tyvek® Wrap Cap Fasteners, or recommended fasteners, FlexWrap™ corners. StraightFlash™ should be applied the length of the sill prior where flashing will be installed; however, fasteners can be installed over the to placing the FlexWrap™ corners. The FlexWrap™ corners should be at least flashing. 12” long allowing for 6” up the jamb and 6” of overlap on the StraightFlash™ sill 10. Great Stuff Pro™ Window and Door Polyurethane Foam Sealant can be used in lieu flashing. When applying the 3-piece flashing detail to the head of the opening, of sealant to create a continuous seal around the interior perimeter of the window the StraightFlash™ head piece should be applied prior to installing the FlexWrap™ openings. When using Great Stuff Pro™ Window and Door Polyurethane Foam corner flashing. Minimum overlapping of the StraightFlash™ head flashing and Sealant in perimeter openings less than ½”, apply using the plastic extension tip for jamb flashing should be a minimum of 6”. the Great Stuff™ Dispenser Gun during installation. 20. Packaged Terminal Air Conditioners (PTAC) units can be flashed in accordance 11. For high performance installations exceeding ASTM E1677 wind loading pressures with the non-flanged window section or with the DuPont™ VersaFlange™ for brick (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance mold window sections of this installation guideline. of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff 21. Suitable substrates for DuPont™ Tyvek® Fluid Applied Products include concrete Pro™ Polyurethane Foam Sealant or other recommended foam. Sealant should masonry unit (CMU), concrete (48 hrs. for green concrete), exterior gypsum, OSB, be installed over the foam between the window frame and rough opening around plywood, wood, and metal. Contact your local DuPont™ Tyvek® Specialist for use the entire interior perimeter. If Great Stuff Pro™ Polyurethane Foam Sealant, or other with pressure treated or fire retardant treated wood (FRT).

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 4 22. DuPont™ Tyvek® Fluid Applied Products should only be used for wall systems that include a continuous path for drainage allowing moisture that penetrates the facade to exit to the exterior. The drainage path should be continuous throughout the wall assembly, including but not limited to areas such as eyebrows, band boards, penetrations, or other locations where transitions and changes of plane occur. For membrane drainage wall systems, ensure that the drainage path is not blocked or disrupted to prevent excess moisture buildup in the wall cavity. 23. Uncured Tyvek® Fluid Applied Products must not come in contact with building wraps due to potential impact on performance properties. 24. DuPont™ Tyvek® CommercialWrap® and Tyvek® CommercialWrap® D may be installed over Tyvek® Fluid Applied Products after 48 hours of curing at 70°F (20°C) and 50% RH. 25. Tyvek® Fluid Applied Products can be applied to damp surfaces. A surface is considered damp if there is no visible water on the surface and no transfer of water to the skin when touched. 26. DuPont™ Tyvek® Fluid Applied Flashing and Joint Compound+ can be troweled or brushed to the required thickness in any application outlined in the guide. 27. Tyvek® Fluid Applied Products should be applied when air and surface temperatures are above 25°F. Do not install once the ambient temperature exceeds 95°F (35°C), unless the application surface is shaded. The maximum surface temperature for application is 140°F (60°C). 28. Tyvek® Fluid Applied Products may be overcoated once a tack-free skin has formed. Exterior insulation and/or exterior facade may be installed after Tyvek® Fluid Applied Products have cured for 48 hours. Please refer to Drying/Curing information in the DuPont™ Tyvek® Fluid Applied WB+™ Wall and Substrate Guidelines (43-D100680). 29. Performance testing, included but not limited to peel adhesion, pull strength analysis, field or third-party testing of air and/or water barrier properties, should be conducted after Tyvek® Fluid Applied Products are fully cured (~14 days). 30. Tyvek® CommercialWrap® and Tyvek® CommercialWrap® D must not come in direct contact with other manufacturers’ cured or uncured fluid-applied and/or deck waterproofing products due to potential impact on performance properties. DuPont™ StraightFlash™ can be used as transitional membrane. 31. DuPont requires Tyvek® WRBs and Tyvek® Fluid Applied Products be covered within nine months (270 days) of installation. 32. The maximum in-service temperature for Tyvek® WRBs, DuPont Self-Adhered Flashing Products, and Tyvek® Fluid Applied Products is 180°F.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 5 Key Installation Requirements for Drainable Window / Door Installation

When flashing windows or doors, the following principles must be followed: • Ensure that window / door and flashing system design takes into account common • When installed properly, DuPont™ StraightFlash™, DuPont™ VersaFlange™, DuPont™ factors that will impact performance, such as: ™ ™ FlexWrap , and DuPont Flashing Tape provide nail sealability at window/door – Climate considerations: Rainfall, Wind, Temperature (hot / cold cycles), Humidity openings to help protect critical window-wall interfaces. Metal sill pan flashing may – Building design: Window / Wall Design (overhangs, recessed openings, bump- be used, but must not replace flexible sill flashing that provides nail sealability. outs), Wall Assembly (wood frame or masonry), Window System (wood or vinyl), • DuPont Self-Adhered Flashing Products comply with AAMA 711-13, Voluntary New Construction or Replacement Window drainage path Specification for Self Adhering Flashing Used for Installation of Exterior Wall – UV exposure prior to the construction of the exterior facade Fenestration Products, which has a modified version of ASTM D 1970 and it is more representative for vertical wall applications. – Compliance with fire resistance code requirements. For more information about NFPA 285 compliant wall assemblies utilizing Tyvek® WRBs visit building.dupont.com. • Tyvek® Fluid Applied Flashing and Joint Compound+ complies with AAMA 714-19, Voluntary Specification for Liquid Applied Flashing Used to Create a Water-Resistive • Field testing the window / door and wall installation as a complete system is a Seal around Exterior Wall Openings in Buildings. recommended best practice. • Ensure that sill flashing does not slope to the interior. An exterior slope is • Use of trained installers is highly recommended. recommended, but not required. Sealants and Adhesives/Primers • Direct water onto an acceptable air and water barrier drainage plane with an Review the manufacturers’ literature or to confirm that the product(s) used have unobstructed path to the exterior of the wall. Provide a drainage path for any water the chemical and adhesive properties necessary for use with Tyvek® WRBs, DuPont intrusion through the window/door attachment system that collects at the sill. Self-Adhered Flashing Products, and DuPont™ Tyvek® Fluid Applied Products. Ensure • Properly integrate flashing with acceptable DuPont™ Tyvek® WRB in accordance with the sealant materials meet the installation temperature requirements of the sealant the instructional drawing. Self-adhered flashing must be applied with a minimum 2” manufacturer. Refer to Chemical Compatibility of Representative Building Sealants and lap onto the WRB. Adhesives/Primers for more information about chemical compatibility. • DuPont requires that FlexWrap™, FlexWrap™ EZ, StraightFlash™, and VersaFlange™ be covered within nine months (270 days) of installation. DuPont requires that DuPont™ Flashing Tape be covered within four months (120 days) of installation. • Properly prepare all surfaces (remove dirt, dust, or moisture, etc.) per manufacturer’s recommendations. • Barrier installations (full perimeter seal on exterior) are acceptable only in the following instances: – Slab on grade doors, store front windows, or other systems with built-in drainage mechanisms that have potential for exposure to standing water – Surface barrier wall systems with non-water sensitive framing material (i.e., CMU walls) – Very low wind / rain exposure regions (southwest / desert) that follow AAMA 2400 installation guideline

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 6 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window

Method applies to following products: DuPont™ StraightFlash™, and DuPont™ FlexWrap™

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically-Fastened Water-Resistive and or slightly below the sill framing to allow for positive drainage. Air Barrier (WRB) Installation Guidelines for Buildings Greater Than 4 Stories that can be found at building.dupont.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 7 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window

8“

A

B 8“

STEP 3 STEP 4 Prepare the Tyvek® WRB for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure flap with tape. A. Cut an opening in the Tyvek® WRB using a square cut around the perimeter of the B. Temporarily secure the Tyvek® WRB with DuPont™ Tyvek® Tape around rough opening rough opening. before flashing is installed to help facilitate flashing installation.

B. Cuts should be made along the dashed indicated lines. (Ensure that the Tyvek® WRB is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 8 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window

DO NOT STRETCH

Wide release Narrow release paper

6” A

B A No gap in corner Release paper B for backdam Window jamb

DuPont™ Fold to break scores FlexWrap™ OPTIONAL BACKDAM DETAIL WHEN USING Sill width +12” 9” WIDE DUPONT™ FLEXWRAP™ WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

STEP 5 STEP 6 A. Cut DuPont™ FlexWrap™ at least 12” LONGER than width of rough opening sill (S). A. Remove wide piece of release paper. Position on horizontal sill by aligning the Use roll widths sufficient to achieve a minimum of 1” adhesionBEYOND where the inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” window frame will be located, ensuring 2”– 3” adhesion onto the face of the wall. of the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up each jamb. Adhere into rough opening. B. Inspect installation surface to ensure surface is free of dirt or substances that could interfere with adhesion as well as any sharp protrusions. Optional Back Dam: Fold 9” FlexWrap™ to break perforation. Remove center piece of release paper. Cover horizontal sill to accommodate back dam as appropriate, and adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” release paper on FlexWrap™ inside rough opening to finish back dam after window installation. B. Remove narrow release paper.

DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 9 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window

2“ minimum overlap

A

B

B

A

INCORRECT CORRECT DuPont™ FlexWrap™ DuPont™ StraightFlash™ reverse flashed overlaps FlexWrap™

STEP 7 STEP 8 A. Fan out the DuPont™ FlexWrap™ at corners and adhere onto face of wall. Continue A. Cut the jamb flashing the vertical length of the rough opening. Jamb flashing adhering onto face of wall along sill. Coverage of FlexWrap™ should be 2”– 3” onto should be long enough to overlap the sill flashing by at least 2” and be overlapped the face of the wall. by future head flashing by at least 2”.

B. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles B. Wrap 9” DuPont™ StraightFlash™ into the rough opening at each jamb and onto wall and bubbles by smoothing surface and repositioning as necessary. face. The flashing should align with the interior edge of the jamb framing.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 10 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window

A

A

INCORRECT CORRECT DuPont™ FlexWrap™ DuPont™ StraightFlash™ reverse flashed overlaps FlexWrap™

STEP 9 STEP 10 A. Apply DuPont™ Adhesive/Primer or recommended primer to the top of the jambs A. Adhere DuPont™ FlexWrap™ to the head using the same installation process as and exposed sheathing. shown in steps 6 and 7 for the sill flashing. Make sure theFlexWrap ™ is cut long enough to overlap the jamb flashing by at least 2”.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 11 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window

B

Drip cap A (optional)

A

STEP 11 STEP 12 – OPTIONAL A. Install window per manufacturer’s installation instructions. Apply an exterior A. As a best practice for high exposure areas, install metal drip cap above the head perimeter seal using backer rod and sealant along the jambs and head of the joint when specified. window opening. B. Apply a strip of 4” DuPont™ StraightFlash™ over the drip cap. NOTE: Ensure window and sealant installation allows for drainage at the sill. If sealant is applied at the sill, as a best practice, ensure that there are at least two (2) 2" gaps in the sealant bead for every 4" of window to allow for drainage.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 12 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window

Interior A B

C

STEP 13 STEP 14 A. Flip down the head flap andtrim 1”-2” above the window opening. Terminate A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ flap along the top of the window with 3”DuPont ™ Tyvek® Tape or 4” DuPont™ Window and Door Polyurethane Foam Sealant on window interior to resist air and StraightFlash™. (See Special Considerations for when 3” Tyvek® Tape is allowed). water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane Foam Sealant in perimeter openings less than 1/2”, apply using the plastic extension B. Apply 4” StraightFlash™ over the diagonal seams. tip for the Great Stuff Pro™ Dispenser Gun during installation. C. For high performance designs or areas of extreme exposure use 4” StraightFlash™ NOTE: For high performance installations exceeding ASTM E1677 wind loading to seal the head flap and install additional recommended mechanical fasteners pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration through the flashing at the head flap and perimeter of window. resistance of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant should be installed over the foam between the window frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 13 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

Method applies to following products: DuPont™ StraightFlash™ and DuPont™ FlexWrap™

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically-Fastened Water-Resistive and or slightly below the sill framing to allow for positive drainage. Air Barrier (WRB) Installation Guidelines for Buildings Greater Than 4 Stories that can be found at building.dupont.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 14 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

Wide release paper Narrow release paper

DO NOT STRETCH

A 6” B Release paper for backdam

B C Fold to break scores No gap in corner OPTIONAL BACKDAM DETAIL WHEN USING 9” WIDE DUPONT™ FLEXWRAP™ Window jamb

DuPont™ Sill width +12” FlexWrap™

WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

STEP 3 STEP 4 A. Cut an opening in the DuPont™ Tyvek® WRB using a full cut out around the A. Remove wide piece of release paper. Position on horizontal sill by aligning the perimeter of the opening. inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” of the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up B. Temporarily secure Tyvek® WRB with DuPont™ Tyvek® Tape around rough opening each jamb. Adhere into rough opening. before flashing is installed to help facilitate flashing installation. Optional Back Dam: Fold 9” FlexWrap™ to break perforation. Remove center piece of C. Cut DuPont™ FlexWrap™ at least 12” LONGER than width of rough opening sill. release paper. Cover horizontal sill to accommodate back dam as appropriate, and Use roll widths sufficient to achieve a minimum of 1” adhesionBEYOND where adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” the window frame will be located, ensuring 2”– 3” adhesion onto the face of the release paper on FlexWrap™ inside rough opening to finish back dam after window wall. installation. D. Inspect installation surface to ensure surface is free of dirt or substances that could B. Remove narrow release paper. interfere with adhesion as well as any sharp protrusions. DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 15 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

2“ minimum overlap

B

A

INCORRECT CORRECT DuPont™ FlexWrap™ DuPont™ StraightFlash™ reverse flashed overlaps FlexWrap™

STEP 5 STEP 6 A. Fan out the DuPont™ FlexWrap™ at corners and adhere onto face of wall. Continue A. Cut the jamb flashing the vertical length of the rough opening. Jamb flashing adhering onto face of wall along sill. Coverage of FlexWrap™ should be 2”– 3” onto should be long enough to overlap the sill flashing by at least 2” and be overlapped the face of the wall. by future head flashing by at least 2”. Use roll widths sufficient to achieve a minimum of 1” adhesion BEYOND where the window frame will be located, B. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles ensuring 2”– 3” adhesion onto the face of the wall. and bubbles by smoothing surface. B. Wrap 9” DuPont™ StraightFlash™ into the rough opening at each jamb and onto wall face. The flashing should align with the interior edge of the jamb framing.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 16 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

A A

B

C

INCORRECT CORRECT DuPont™ FlexWrap™ DuPont™ StraightFlash™ reverse flashed overlaps FlexWrap™

STEP 7 STEP 8

™ ™ A. Adhere DuPont FlexWrap to the head using the same installation process as Install Floating Lintel ™ shown in steps 4 and 5 for the sill flashing. Make sure theFlexWrap is cut long A. Cut flap in theTyvek ® WRB. enough to overlap the jamb flashing by at least 2 inches. B. Apply DuPont™ Adhesive/Primer or recommended primer to exposed sheathing. C. Install lintel per plans and specifications.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 17 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

D

C B C

B D A

A

STEP 9 STEP 9 (ALTERNATE) Head Detail Using Metal Pan and Mechanically Attached Through Wall Flashing Head Detail Using Self-Adhered Through Wall Flashing A. Install corrosion-resistant metal pan with drip and soldered/sealed end dams above A. Embed through wall flashing end dams in sealant and install along outer edge lintel. Extend flashing beyond the end of lintel. of lintel. B. Install through wall flashing a minimum of 3” onto the wall sheathing, overlapping B. Install self-adhered through wall flashing with a minimum of 3” adhering to the the lintel, and extending onto the horizontal surface of the metal pan leaving wall sheathing, then overlapping the lintel. Extend the through wall flashing a minimum 1" of metal drip exposed. minimum of 1/4” beyond the outside edge of the lintel to form a drip edge.

C. Cut a vertical slit in the through wall flashing to accommodate the vertical edge of C. OPTIONAL: Install 4” wide StraightFlash™ along the top edge of through wall the metal pan. flashing to achieve the 2” minimum contact to the exposed exterior sheathing.

D. Install 4” wide DuPont™ StraightFlash™ along the top edge of through wall flashing D. Apply sealant along the edges of the through wall flashing. to achieve the 2” minimum contact to the exposed exterior sheathing.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 18 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

2” min

B

C

4” DuPont™ StraightFlash™

A Metal sill pan flashing

STEP 10 STEP 11 A. Fold head flap back into place. Install Metal Sill Pan B. Tape along bottom edge of cut in the Tyvek® WRB with DuPont™ StraightFlash™. A. Anchor the non-corrosive metal sill pan flashing to the wall and integrate to the Tyvek® WRB with 4" StraightFlash™. C. Use 4” wide StraightFlash™ at diagonal cut in Tyvek® WRB to secure head flap.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 19 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

Interior

C

STEP 12 STEP 13 A. Install remaining masonry with weeps along flashing. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ Window and Door Polyurethane Foam Sealant on window interior to resist air and B. Install window per manufacturer’s instructions. water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane Foam C. Seal all four sides of the perimeter of the window. Sealant in perimeter openings less than ½”, apply using the plastic extension tip for the Great Stuff Pro™ Dispenser Gun during installation. DO NOT SEAL ANY WEEPS OF WINDOW FRAME. NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant should be installed over the foam between the window frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 20 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

BRICK VENEER BRICK VENEER

EXTERIOR GYPSUM EXTERIOR GYPSUM BOARD BOARD STEEL DUPONT™ TYVEK® STUD WALL DUPONT™ TYVEK® STEEL STUD COMMERCIALWRAP® OR COMMERCIALWRAP® OR WALL TYVEK® COMMERCIALWRAP® D TYVEK® COMMERCIALWRAP® D BATT INSULATION SEALANT (OPTIONAL) ™ ™ BATT DUPONT STRAIGHTFLASH INSULATION GYPSUM MECHANICAL MECHANICAL BOARD GYPSUM FASTENER (OPTIONAL) FASTENER (OPTIONAL) BOARD DUPONT™ STRAIGHTFLASH™ DUPONT™ STRAIGHTFLASH™ SELF-ADHERED THROUGH MECHANICALLY ATTACHED WALL FLASHING INSTALLED THROUGH WALL FLASHING PER MANUFACTURER'S INSTALLED PER MANUFACTURER'S SPECIFICATIONS SPECIFICATIONS DUPONT™ TYVEK® DUPONT™ TYVEK® COMMERCIALWRAP® OR COMMERCIALWRAP® OR TYVEK® COMMERCIALWRAP® D TYVEK® COMMERCIALWRAP® D END DAM END DAM

METAL PAN WITH DRIP DRIP EDGE

DUPONT™ FLEXWRAP™ LOOSE-LAID STEEL LINTEL (2" ONTO FACE OF WALL) DUPONT™ FLEXWRAP™ LOOSE-LAID STEEL LINTEL (2" ONTO FACE OF WALL) BACKER ROD AND SEALANT SEALANT (BY OTHERS) BACKER ROD AND (USE BACKER ROD AS SEALANT SEALANT (BY OTHERS) NECESSARY) WINDOW FRAME (USE BACKER ROD AS NECESSARY) WINDOW FRAME

FLOATING LINTEL WITH METAL PAN AND MECHANICALLY FLOATING LINTEL WITH SELF-ADHERED THROUGH WALL ATTACHED THROUGH WALL FLASHING (SIDE VIEW) FLASHING (SIDE VIEW)

NOTE: For additional CAD details, visit building.dupont.com

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 21 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

BRICK VENEER

EXTERIOR GYPSUM BOARD EXTERIOR SHEATHING DUPONT™ TYVEK® STEEL STUD ® COMMERCIALWRAP OR SEALANT WALL TYVEK® COMMERCIALWRAP® D

DUPONT™ TYVEK® BATT COMMERCIALWRAP® OR INSULATION TYVEK® COMMERCIALWRAP® D MECHANICAL GYPSUM FASTENER (OPTIONAL) BOARD BRICK FACADE

SELF-ADHERED THROUGH WALL FLASHING INSTALLED PER MANUFACTURER'S SPECIFICATIONS 3” DUPONT™ TYVEK® TAPE OR DUPONT SELF-ADHERED DUPONT™ TYVEK® FLASHING PRODUCT COMMERCIALWRAP® OR TYVEK® COMMERCIALWRAP® D

END DAM

SELF-ADHERED THROUGH DRIP EDGE WALL FLASHING OR DRIP CAP SET IN SEALANT

DUPONT™ FLEXWRAP™ LOOSE-LAID STEEL LINTEL (2" ONTO FACE OF WALL) SEALANT BEAD BACKER ROD AND SEALANT SEALANT (BY OTHERS) (USE BACKER ROD AS NECESSARY) WINDOW FRAME

DUPONT™ STRAIGHTFLASH™

FLOATING LINTEL WITH THROUGH WALL FLASHING ADHERED HEAD DETAIL FOR ATTACHED LINTEL WITH SELF-ADHERED TO DUPONT™ TYVEK® WRB (SIDE VIEW) THROUGH WALL FLASHING (SIDE VIEW)

NOTE: For additional CAD details, visit building.dupont.com

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 22 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

CAVITY SEAL INSERT

9” DUPONT™ ™ STRAIGHTFLASH MASONRY VENEER WITH BACKER ROD AIRSPACE ALTERNATE CAVITY SEAL AND SEALANT

BACKER ROD AND SEALANT

WINDOW FRAME

FLEXIBLE CAVITY SEAL BONDED TO MASONRY AND DUPONT™ STRAIGHTFLASH™ (EXTEND CAVITY SEAL DOWN AND SEAL TO THE END DAM OF BACKER ROD THE MASONRY SILL FLASHING; SEAL TO AND SEALANT LINTEL AT TOP.)

FIELD CUT BRICK BACKER ROD AND RETURN SEALANT

DUPONT™ TYVEK® WINDOW ANCHOR SCREWED TO 2”X 2” METAL COMMERCIALWRAP® OR INTERIOR FRAMING AND BEDDED IN DUPONT™ TYVEK® COMMERCIALWRAP® ANGLE TO MATCH TYVEK® COMMERCIALWRAP® D SEALANT. ALSO, SEAL AROUND OR TYVEK® COMMERCIALWRAP® D WINDOW PERIMETER OF ANCHOR STRAP.

9" STRAIGHTFLASH™ ADHERED TO INTERIOR VAPOR RETARDER (OR VICE VERSA, WHERE A VAPOR RETARDER IS REQUIRED).

OPTIONAL JAMB DETAIL (TOP VIEW) OPTIONAL JAMB DETAIL (TOP VIEW)

NOTE: For additional CAD details, visit building.dupont.com

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 23 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window with Floating Lintel and Brick Facade

TURN UP FLEXWRAP™ AND ADHERE TO WINDOW FRAME BLOCKING

THERMALLY IMPROVED USE SEALANT TO SEAL SUBSILL FLEXWRAP™ TO WINDOW FRAME 3/4" BLOCKING "L" SHAPED LIGHT GAUGE CORROSION CONTINUOUS RESISTANT METAL BACKER ROD BACKDAM FULLY AND SEALANT EMBEDDED IN SEALANT WITH FOLDED AND SEALED END DAMS

BACKER ROD ALTERNATE ADHERE DUPONT™ AND SEALANT FLASHING DETAIL FLEXWRAP™ TO INTERIOR VAPOR RETARDED (OR VICE ADHERE STRAIGHTFLASH™ VERSA), WHERE VAPOR TO FLEXWRAP™ AND OVER DUPONT™ RETARDER IS REQUIRED) BACK LEG OF FLASHING PAN FLEXWRAP™ SILL

BACKER ROD AND SEALANT BRICK FACADE SILL WITH ANCHORS (AS DUPONT™ REQUIRED) TYVEK® WRB

THROUGH WALL EXTERIOR FLASHING OR SHEATHING CORROSION RESISTANT FLASHING PAN WITH DRIP AND SOLDERED/SEALED END DAMS

SUPPORT WINDOW ™ ® SYSTEM AND DUPONT TYVEK COMMERCIALWRAP® OR SUBSILL AS ® ® REQUIRED TYVEK COMMERCIALWRAP D

INTERIOR EXTERIOR

SILL DETAIL (SIDE VIEW) SILL DETAIL (SIDE VIEW) METAL THROUGH WALL FLASHING

NOTE: For additional CAD details, visit building.dupont.com

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 24 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Door on Slab

This door detail can be used for any non-flanged door rough opening, including storefront or hollow metal doors. Use of this detail requires the ability to protect the rough opening at the jambs and head with DuPont Self-Adhered Flashing. For welded hollow metal doors or other welded-in-place doors where the rough opening cannot be protected, the DuPont™ Tyvek® WRB must be terminated on the face of the wall around the perimeter of the opening with DuPont™ StraightFlash™.

Method applies to following products: DuPont™ StraightFlash™ and DuPont™ FlexWrap™

STEP 1 STEP 2 A. Cut rough opening in sheathing for door. A. Wrap wall as shown in DuPont™ Tyvek® Mechanically-Fastened Water-Resistive and Air Barrier (WRB) Installation Guidelines for Buildings Greater Than 4 Stories that can be found at building.dupont.com. Do not install fasteners within 6” of the jambs of the openings and within 9” of the head of the openings.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 25 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Door on Slab

8” A

B

STEP 3 STEP 4 Prepare the Tyvek® WRB for door installation. A. Flip the head flap up to expose the sheathing and temporarily secure with tape. A. Cut an opening in the Tyvek® WRB using a square cut around the perimeter of the B. Temporarily secure Tyvek® WRB with DuPont™ Tyvek® Tape around rough opening rough opening. before flashing is installed to help facilitate flashing installation.

B. Cuts should be made along the dashed indicated lines. (Ensure that the Tyvek® WRB is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 26 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Door on Slab

B

A

STEP 5 STEP 6 A. Prepare the sill flashing and/or threshold per manufacturer’s recommendation and A. Shim, level, and anchor pan/threshold per manufacturer’s instructions flashing to seal the corner pan flashing with sealant if applicable. concrete. B. Inspect installation surface to ensure surface is free of dirt or substances that could B. Seal corner pan flashing seams with sealant if applicable. interfere with adhesion as well as any sharp protrusions.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 27 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Door on Slab

A

2“ minimum overlap

A B

STEP 7 STEP 8 A. Wrap 9” DuPont™ StraightFlash™ into the rough opening at each jamb and onto wall A. Apply DuPont™ Adhesive/Primer or recommended primer to the top of the jambs face. The flashing should align with the interior edge of the jamb framing. Cut the and exposed sheathing. jamb flashing the vertical length of the rough opening. B. Jamb flashing should be long enough to overlap the sill flashing by at least 2” and be overlapped by future head flashing by at least 2”.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 28 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Door on Slab

B A

A Drip cap (optional)

INCORRECT CORRECT DuPont™ FlexWrap™ DuPont™ StraightFlash™ reverse flashed overlaps FlexWrap™

STEP 9 STEP 10 – OPTIONAL A. Adhere DuPont™ FlexWrap™ to the head. Make sure the FlexWrap™ is cut long A. As a best practice for high exposure areas, install metal drip cap above the head enough to overlap the jamb flashing by at least 2”. joint when specified.

B. Use sufficient width ofFlexWrap ™ to avoid reverse shingling of flashing at the jamb B. Apply a strip of 4” DuPont™ StraightFlash™ over the drip cap. and head interface. See detail above.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 29 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Door on Slab

B A

C

A

STEP 11 STEP 12 A. Flip down the head flap and trim 1”-2” above the door opening. Terminate flap along A. Install door per manufacturer’s installation instructions. the top of the door with 3” DuPont™ Tyvek® Tape or 4” DuPont™ StraightFlash™. (See B. If applicable, glaze door per manufacturer’s instructions. Special Considerations for when 3” Tyvek® Tape is allowed). B. Apply 4” StraightFlash™ over the diagonal seams. C. Install remaining DuPont™ Tyvek® Wrap Cap Fasteners or recommended fasteners at head according to the fastening schedule (every 12” to 18” depending on the vertical stud line).

NOTE: For high performance designs or areas of extreme exposure use 4” StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of door.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 30 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Door on Slab

Interior Exterior

Sealant Sealant

SIDE VIEW

Interior

STEP 13 A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ Window and Door Polyurethane Foam Sealant on door interior to resist air and water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane Foam Sealant in perimeter openings less than ½”, apply using the plastic extension tip for the Great Stuff Pro™ Dispenser Gun during installation. NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant should be installed over the foam between the door frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the door frame, shave the excess cured foam flush with the door frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 31 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Door on Slab

BUILDING SHEATHING – SEE DRAWINGS BY OTHERS DUPONT™ TYVEK® ® COMMERCIALWRAP or HOLLOW METAL DOOR FRAME – ® ® ™ ® TYVEK COMMERCIALWRAP D DUPONT TYVEK BUILDING SHEATHING – SEE DRAWINGS BY OTHERS COMMERCIALWRAP® or SEE DRAWINGS BY OTHERS TYVEK® COMMERCIALWRAP® D DOOR – SEE DUPONT™ DRAWINGS BY OTHERS STRAIGHTFLASH™

DUPONT™ STRAIGHTFLASH™

DUPONT™ FLEXWRAP™

METAL HEAD FLASHING WITH CLOSED ENDS

SEALANT HOLLOW METAL DOOR FRAME – SEE DRAWINGS BY OTHERS

DOOR – SEE DRAWINGS BY OTHERS

HEAD DETAIL (SIDE VIEW) – HOLLOW METAL DOOR JAMB DETAIL (TOP VIEW) – HOLLOW METAL DOOR

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 32 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Slab

Method applies to following products: DuPont™ StraightFlash™ and DuPont™ FlexWrap™

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. A. Wrap wall as shown in DuPont™ Tyvek® Mechanically-Fastened Water-Resistive and Air Barrier (WRB) Installation Guidelines for Buildings Greater Than 4 Stories that can be found at building.dupont.com. Do not install fasteners within 6” of the jambs of the openings and within 9” of the head of the openings.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 33 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Slab

A 8” B

STEP 3 STEP 4 Prepare the Tyvek® WRB for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure with tape. A. Cut an opening in the Tyvek® WRB using a square cut around the perimeter of the B. Temporarily secure Tyvek® WRB with DuPont™ Tyvek® Tape around rough opening rough opening. before flashing is installed to help facilitate flashing installation.

B. Cuts should be made along the dashed indicated lines. (Ensure that the Tyvek® WRB is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 34 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Slab

A

STEP 5 STEP 6 A. Prepare the sill flashing per manufacturer’s recommendation and seal the corner A. Shim, level and anchor pan per manufacturer’s instructions flashing to concrete. pan flashing with sealant. B. Seal corner pan flashing seams with sealant. B. Inspect installation surface to ensure surface is free of dirt or substances that could interfere with adhesion as well as any sharp protrusions.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 35 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Slab

A

2“ minimum overlap

B

A

STEP 7 STEP 8 A. Wrap 9” DuPont™ StraightFlash™ into the rough opening at each jamb and onto wall A. Apply DuPont™ Adhesive/Primer or recommended primer to the top of the jambs face. The flashing should align with the interior edge of the jamb framing. Cut the and exposed sheathing. jamb flashing the vertical length of the rough opening. B. Jamb flashing should be long enough to overlap the sill flashing by at least 2” and be overlapped by future head flashing by at least 2”.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 36 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Slab

B A

A C

INCORRECT CORRECT DuPont™ FlexWrap™ DuPont™ StraightFlash™ reverse flashed overlaps FlexWrap™

STEP 9 STEP 10 A. Adhere DuPont™ FlexWrap™ to the head. Make sure the FlexWrap™ is cut long A. Flip down the head flap and trim 1”-2” above the window opening. Terminate enough to overlap the jamb flashing by at least 2”. flap along the top of the window with 3”DuPont ™ Tyvek® Tape or 4” DuPont™ StraightFlash™. (See Special Considerations for when 3” Tyvek® Tape is allowed). B. Use sufficient width ofFlexWrap ™ to avoid reverse shingling of flashing at the jamb and head interface. See detail above. B. Apply 4” StraightFlash™ over the diagonal seams. C. Install remaining DuPont™ Tyvek® Wrap Cap Fasteners or recommended fasteners at head according to the fastening schedule (every 12” to 18” depending on the vertical stud line).

NOTE: For high performance designs or areas of extreme exposure use 4” StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window. © 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 37 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Slab

Exterior Interior

Sealant

Sealant

Backer rod

SIDE VIEW

A Interior

STEP 11 STEP 12 A. Install store front window per manufacturer’s installation instructions. A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ Window and Door Polyurethane Foam Sealant on window interior to resist air and B. Glaze windows per manufacturer’s instructions. water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane Foam Sealant in perimeter openings less than ½”, apply using the plastic extension tip for the Great Stuff Pro™ Dispenser Gun during installation. NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant should be installed over the foam between the window frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 38 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Knee Wall

Method applies to following products: DuPont™ StraightFlash™ and DuPont™ FlexWrap™

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically-Fastened Water-Resistive or slightly below the sill framing to allow for positive drainage. and Air Barrier Installation Guidelines for Buildings Greater Than 4 Stories that can be found at building.dupont.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 39 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Knee Wall

A B 8”

STEP 3 STEP 4 Prepare the Tyvek® WRB for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure with tape. A. Cut an opening in the Tyvek® WRB using a square cut around the perimeter of the B. Temporarily secure Tyvek® WRB with DuPont™ Tyvek® Tape around rough opening rough opening. before flashing is installed to help facilitate flashing installation.

B. Cuts should be made along the dashed indicated lines. (Ensure that the Tyvek® WRB is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 40 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Knee Wall

Wide release paper Narrow release DO NOT STRETCH paper

Release paper A for backdam

Fold to break scores No gap in corner OPTIONAL BACKDAM DETAIL WHEN USING B 9” WIDE DUPONT™ FLEXWRAP™ Window jamb

Sill width +12” DuPont™ FlexWrap™

A WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

STEP 5 STEP 6 A. Cut DuPont™ FlexWrap™ at least 12” LONGER than width of rough opening sill (S). A. Remove wide piece of release paper. Position on horizontal sill by aligning the Use roll widths sufficient to achieve a minimum of 1” adhesionBEYOND where the inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” window frame will be located, ensuring 2”– 3” adhesion onto the face of the wall. of the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up each jamb. Adhere into rough opening. B. Inspect installation surface to ensure surface is free of dirt or substances that could interfere with adhesion as well as any sharp protrusions. Optional Back Dam: Fold 9” FlexWrap™ to break perforation. Remove center piece of release paper. Cover horizontal sill to accommodate back dam as appropriate, and adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” release paper on FlexWrap™ inside rough opening to finish back dam after window installation. B. Remove narrow release paper.

DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS. C. Firmly press FlexWrap™ into the corners

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 41 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Knee Wall

2“ minimum overlap

B

A

B

C

A

INCORRECT CORRECT DuPont™ FlexWrap™ DuPont™ StraightFlash™ reverse flashed overlaps FlexWrap™

STEP 7 STEP 8 A. Fan out the DuPont™ FlexWrap™ at corners and adhere onto face of wall. Continue A. Wrap 9” StraightFlash™ into the rough opening at each jamb and onto wall face. adhering onto face of wall along sill. Coverage of FlexWrap™ should be 2”– 3” onto The flashing should align with the interior edge of the jamb framing. Cut the jamb the face of the wall. flashing the vertical length of the rough opening. B. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles B. Jamb flashing should be long enough to overlap the sill flashing by at least 2” and and bubbles by smoothing surface and repositioning as necessary. be overlapped by future head flashing by at least 2”. C. Shim, level and anchor sill pan flashing and seal corner seams per manufacturer’s instructions with sealant.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 42 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Knee Wall

A

A

INCORRECT CORRECT DuPont™ FlexWrap™ DuPont™ StraightFlash™ reverse flashed overlaps FlexWrap™

STEP 9 STEP 10 A. Spray the top of the jambs and exposed sheathing with DuPont™ Adhesive/Primer A. Adhere DuPont™ FlexWrap™ to the head using the same installation process as or recommended primer. shown in steps 6 and 7 for the sill flashing. Make sure theFlexWrap ™ is cut long enough to overlap the jamb flashing by at least 2”.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 43 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Knee Wall

B A C

STEP 11 STEP 12 A. Install storefront window per manufacturer’s installation instructions. A. Flip down the head flap and trim 1”-2” above the window opening. Terminate flap along the top of the window with 3”DuPont ™ Tyvek® Tape or 4” DuPont™ B. Glaze windows per manufacturer’s instructions. StraightFlash™. (See Special Considerations for when 3” Tyvek® Tape is allowed). B. Apply 4” StraightFlash™ over the diagonal seams. C. Install remaining DuPont™ Tyvek® Wrap Cap Fasteners or recommended fasteners at head per the fastening schedule (every 12” to 18” depending on the vertical stud line).

NOTE: For high performance designs or areas of extreme exposure use 4” StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 44 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Storefront Window on Knee Wall

Interior

STEP 13 A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ Window and Door Polyurethane Foam Sealant on window interior to resist air and water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane Foam Sealant in perimeter openings less than 1/2”, apply using the plastic extension tip for the Great Stuff Pro™ Dispenser Gun during installation. NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant should be installed over the foam between the window frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 45 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Integral Flanged Window

Method applies to following products: DuPont™ StraightFlash™, DuPont™ FlexWrap™ and DuPont™ Flashing Tape

Exterior Exterior STEP 1 Prepare Tyvek® WRB for window installation:

® 8“ minimum A. Make an “I-Cut” in the Tyvek WRB (a modified I-Cut is also acceptable). For an “I-Cut” begin with a horizontal cut across the bottom and the top of the window B frame (for round top windows, the cut should begin 2” above the mull joint). From B the center cut straight down to the sill. B. Cut two 45° degree slits a minimum of 8” from the corner of the header to create a flap above the rough opening to expose sheathing or framing members and to allow head flashing installation (see step 5). Flip head flap up and temporarily 8“ secure with DuPont™ Tyvek® Tape. Some windows and flashing widths may require minimum A longer slits. C. Fold side flaps into rough opening, cut excess flaps, and secure.

NOTE: See the details in this guide for alternative flashing Methods A, B, and C for flanged windows aligned with Section 7 of FMA/AAMA 100-12,Standard Practice for the Installation of Windows with Flanges or Mounting Fins in Wood Framed Construction for Extreme Wind/Water Conditions.

B

C

A

C

Interior

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 46 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Integral Flanged Window

Wide release paper DO NOT STRETCH Narrow release paper

A

Release paper for backdam B B No gap in corner Fold to break scores 6“ minimum Window jamb OPTIONAL BACKDAM DETAIL WHEN USING 9” WIDE DUPONT™ FLEXWRAP™ DuPont™ FlexWrap™

Sill width +12” WRONG Sill CORRECT

A FRONT VIEW CORNER DETAIL

STEP 2 STEP 3 A. Cut DuPont™ FlexWrap™ at least 12” LONGER than width of rough opening sill (S). A. Remove wide piece of release paper. Position on horizontal sill by aligning the Use roll widths sufficient to achieve a minimum of 1” adhesionBEYOND where the inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” window frame will be located, ensuring 2”– 3” adhesion onto the face of the wall. of the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up each jamb. Adhere into rough opening. B. Inspect installation surface to ensure surface is free of dirt or substances that could interfere with adhesion as well as any sharp protrusions. Optional Back Dam:Fold 9” FlexWrap™ to break perforation. Remove center piece of release paper. Cover horizontal sill to accommodate back dam as appropriate, and adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” release paper on FlexWrap™ inside rough opening to finish back dam after window installation. B. Remove narrow release paper.

DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 47 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Integral Flanged Window

B A

A

STEP 4 STEP 5 A. Fan out the DuPont™ FlexWrap™ at corners and adhere onto face of wall. Continue A. Apply continuous bead of sealant at the window head and jambs to wall or back adhering onto face of wall along sill. Coverage of FlexWrap™ should be 2”– 3” onto side of window mounting flange.Do not apply continuous sealant bead across the face of the wall. bottom sill flange to allow for drainage. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow B. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles for drainage. and bubbles by smoothing surface and repositioning as necessary.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 48 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Integral Flanged Window

For rectangular windows

A C

B B

D A

C

C

STEP 6 STEP 7 A. Install window according to manufacturer’s instructions. A. Flip down upper flap ofTyvek ® WRB so it lays flat across head flashing, then trim 1”-2” above the window opening. B. Apply DuPont™ Adhesive/Primer or recommended primer to exposed sheathing. B. Tape along all cuts in Tyvek® WRB and tape across head of the window with 3” C. Cut two pieces of DuPont™ StraightFlash™ or DuPont™ Flashing Tape* for jamb DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ StraightFlash™. (See flashing extending 1” above window head flange and 4” to 6” below bottom edge Special Considerations for when 3” Tyvek® Tape is allowed.) of sill flashing. Remove release paper and press tightly along sides of window frame. C. Install DuPont™ Tyvek® Wrap Cap Fasteners or recommended fasteners at appropriate spacing at head. D. Cut a piece of StraightFlash™ or DuPont™ Flashing Tape* for head flashing, which extends beyond outer edges of jamb flashings. Remove release paper and install NOTE: For high performance designs or areas of extreme exposure use 4” completely covering mounting flange and adhering to exposed sheathing or StraightFlash™ to seal the head flap and install additional mechanical fasteners framing members. through the flashing at the head flap and perimeter of window.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 49 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Integral Flanged Window

Interior

STEP 8 A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ Window and Door Polyurethane Foam Sealant on window interior to resist air and water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane Foam Sealant in perimeter openings less than ½”, apply using the plastic extension tip for the Great Stuff Pro™ Dispenser Gun during installation. NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant should be installed over the foam between the window frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 50 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Integral Flanged Window

For roundtop windows

B

™ DuPont

xW e l

r F a

p ™

™ ™

p p

a a

C

r r

W W

x x

™ ™

t t

e e

n n

l l

o o P

H P

u u

F F

D D

A

6“ minimum

B D

D

STEP 6 STEP 7 A. Apply continuous bead of sealant at the window head and jambs to wall or back Install head flashing side of window mounting flange.Do not apply continuous sealant bead across A. Cut head flashing at least 12” longer than the arc length (H) of round-top window. bottom sill flange to allow for drainage. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow B. Remove both release and install to conform around top of window, covering for drainage. entire mounting flange and adhering to exposed sheathing or framing members. Head flashing should overlap jamb flashings at least 6”. B. Install window according to manufacturer’s instructions.

C. Apply DuPont™ Adhesive/Primer or recommended primer to the top of the jambs and exposed sheathing.

D. Cut two pieces of DuPont™ StraightFlash™ or DuPont™ Flashing Tape* for jamb flashing extending 1” above window head flange and 4” to 6” below bottom edge of sill flashing. Remove release paper and press tightly along sides of window frame.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 51 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Integral Flanged Window

For roundtop windows

C Interior

A

B A

STEP 8 STEP 9 A. Flip down upper flap ofTyvek ® WRB so it lays flat across head flashing, then trim A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ 1”-2” above the window opening. Window and Door Polyurethane Foam Sealant on window interior to resist air and water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane B. Tape along all cuts in Tyvek® WRB and across head of the window with 3” DuPont™ Foam Sealant in perimeter openings less than ½”, apply using the plastic extension Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ StraightFlash™. (See Special tip for the Great Stuff Pro™ Dispenser Gun during installation. Considerations for when 3” Tyvek® Tape is allowed.) NOTE: For high performance installations exceeding ASTM E1677 wind loading C. Install DuPont™ Tyvek® Wrap Cap Fasteners or recommended fastener at pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration appropriate spacing at head. resistance of 6.24 psf, it is necessary to install sealant over the cured foam when NOTE: For high performance designs or areas of extreme exposure use 4” using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other StraightFlash™ to seal the head flap and install additional mechanical fasteners recommended foam. Sealant should be installed over the foam between the window through the flashing at the head flap and perimeter of window. frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. © 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 52 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method A)

Method applies to following products: DuPont™ StraightFlash™, DuPont™ FlexWrap™ and DuPont™ Flashing Tape

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically-Fastened Water-Resistive and or slightly below the sill framing to allow for positive drainage. Air Barrier (WRB) Installation Guidelines for Buildings Greater Than 4 Stories that can be found at building.dupont.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 53 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method A)

8“

A

8“ B

STEP 3 STEP 4 Prepare the Tyvek® WRB for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure with tape. A. Cut an opening in the Tyvek® WRB using a square cut around the perimeter of the B. Temporarily secure Tyvek® WRB with DuPont™ Tyvek® Tape around rough opening rough opening. before flashing is installed to help facilitate flashing installation.

B. Cuts should be made along the dashed indicated lines. (Ensure that the Tyvek® WRB is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 54 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method A)

Wide release paper DO NOT Narrow release STRETCH paper

6” A Release paper for backdam B A

No gap in corner Fold to break scores B OPTIONAL BACKDAM DETAIL WHEN USING Window jamb 9” WIDE DUPONT™ FLEXWRAP™ DuPont™ FlexWrap™ Sill width +12”

WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

STEP 5 STEP 6 A. Cut DuPont™ FlexWrap™ at least 12” LONGER than width of rough opening sill (S). A. Remove wide piece of release paper. Position on horizontal sill by aligning the Use roll widths sufficient to achieve a minimum of 1” adhesionBEYOND where the inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” window frame will be located, ensuring 2”– 3” adhesion onto the face of the wall. of the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up each jamb. Adhere into rough opening. B. Inspect installation surface to ensure surface is free of dirt or substances that could interfere with adhesion as well as any sharp protrusions. Optional Back Dam: Fold 9” FlexWrap™ to break perforation. Remove center piece of release paper. Cover horizontal sill to accommodate back dam as appropriate, and adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” release paper on FlexWrap™ inside rough opening to finish back dam after window installation. B. Remove narrow release paper.

DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 55 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method A)

2“ minimum overlap C

B C

A

B

A

INCORRECT CORRECT DuPont™ FlexWrap™ DuPont™ StraightFlash™ reverse flashed overlaps FlexWrap™

STEP 7 STEP 8 A. Fan out the DuPont™ FlexWrap™ at corners and adhere onto face of wall. Continue A. Install 4” DuPont™ StraightFlash™ into the rough opening at each jamb and onto adhering onto face of wall along sill. Coverage of FlexWrap™ should be 2”– 3” onto wall face. The flashing does not need to align with the interior edge of the jamb the face of the wall. framing. Cut the jamb flashing the vertical length of the rough opening. B. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles B. Jamb flashing should be long enough to overlap the sill flashing by at least 2” and and bubbles by smoothing surface and repositioning as necessary. be overlapped by future head flashing by at least 2”. C. Cover holes in studs with patches of DuPont™ StraightFlash™ as necessary. C. Apply sealant to inside corners of rough opening at jamb/head.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 56 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method A)

B

D

A A

C

C

STEP 9 STEP 10 A. Apply continuous bead of sealant at the window head and jambs to wall or back A. Install window according to manufacturer’s instructions. side of window mounting flange.Do not apply continuous sealant bead across B. Apply DuPont™ Adhesive/Primer or recommended primer to exposed sheathing. bottom sill flange to allow for drainage. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow C. Cut two pieces of DuPont™ StraightFlash™ or DuPont™ Flashing Tape* for jamb for drainage. flashing extending 1” above window head flange and 4” to 6” below bottom edge of sill flashing. Remove release paper and press tightly along sides of window frame.

D. Cut a piece of StraightFlash™ or DuPont™ Flashing Tape* for head flashing, which extends beyond outer edges of jamb flashings. Remove release paper and install completely covering mounting flange and adhering to exposed sheathing or framing members.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 57 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method A)

Interior A C

B

STEP 11 STEP 12 A. Flip down upper flap ofTyvek ® WRB so it lays flat across head flashing, then trim A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ 1”-2” above the window opening. Window and Door Polyurethane Foam Sealant on window interior to resist air and water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane B. Tape along all cuts in Tyvek® WRB and tape across head of the window with 3” Foam Sealant in perimeter openings less than ½”, apply using the plastic extension DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ StraightFlash™. (See tip for the Great Stuff Pro™ Dispenser Gun during installation. Special Considerations for when 3” Tyvek® Tape is allowed.) NOTE: For high performance installations exceeding ASTM E1677 wind loading C. Install DuPont™ Tyvek® Wrap Cap Fasteners or recommended fasteners at pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration appropriate spacing at head. resistance of 6.24 psf, it is necessary to install sealant over the cured foam when NOTE: For high performance designs or areas of extreme exposure use 4” using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other StraightFlash™ to seal the head flap and install additional mechanical fasteners recommended foam. Sealant should be installed over the foam between the window through the flashing at the head flap and perimeter of window. frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 58 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method B)

Method applies to following products: DuPont™ StraightFlash™, DuPont™ FlexWrap™ and DuPont™ Flashing Tape

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically-Fastened Water-Resistive and or slightly below the sill framing to allow for positive drainage. Air Barrier (WRB) Installation Guidelines for Buildings Greater Than 4 Stories that can be found at building.dupont.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 59 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method B)

8“

C D

8“

B B

A

STEP 3 STEP 4 Prepare the Tyvek® WRB for window installation. A. Cut two 45° slits extending from the bottom corner up and away from the window opening to expose approximately 8” of sheathing. This will create a flap at each A. Cut an opening in the Tyvek® WRB using a square cut around the perimeter of the jamb to allow for jamb flashing installation. rough opening. B. Flip the flaps to the side to expose the sheathing and temporarily secure with B. Cuts should be made along the dashed indicated lines. (Ensure that the Tyvek® WRB Tyvek® Tape. is cut flush with the sheathing and is not wrapped into the rough opening.) C. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation. D. Flip the head flap up to expose the sheathing and temporarily secure with DuPont™ Tyvek® Tape.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 60 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method B)

Wide release paper Narrow release paper

DO NOT STRETCH

A

6” A Release paper for backdam C B No gap in corner Fold to break scores B Window jamb OPTIONAL BACKDAM DETAIL WHEN USING 9” WIDE DUPONT™ FLEXWRAP™ DuPont™ FlexWrap™

Sill width +12” WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

STEP 5 STEP 6 A. Apply DuPont™ Adhesive/Primer or recommended primer to exposed sheathing at A. Remove wide piece of release paper. Position on horizontal sill by aligning the jambs and head. inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” of the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up B. Cut DuPont™ FlexWrap™ at least 12” LONGER than width of rough opening sill (S). each jamb. Adhere into rough opening. Use roll widths sufficient to achieve a minimum of 1” adhesionBEYOND where the window frame will be located, ensuring 2”– 3” adhesion onto the face of the wall. Optional Back Dam: Fold 9” FlexWrap™ to break perforation. Remove center piece of release paper. Cover horizontal sill to accommodate back dam as appropriate, and C. Inspect installation surface to ensure surface is free of dirt or substances that could adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” interfere with adhesion as well as any sharp protrusions. release paper on FlexWrap™ inside rough opening to finish back dam after window installation. B. Remove narrow release paper.

DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 61 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method B)

C

B A

A

STEP 7 STEP 8 A. Fan out the DuPont™ FlexWrap™ at corners and adhere onto face of wall. Continue A. Apply continuous bead of sealant at the window head and jambs to wall or back adhering onto face of wall along sill. Coverage of FlexWrap™ should be 2”– 3” onto side of window mounting flange.Do not apply continuous sealant bead across the face of the wall. bottom sill flange to allow for drainage. If sealant is applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow B. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles for drainage. and bubbles by smoothing surface and repositioning as necessary.

C. Cover holes in studs with patches of DuPont™ StraightFlash™ as necessary.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 62 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method B)

For rectangular windows

C C

A A

B B

B

STEP 9 STEP 10 A. Install window according to manufacturer’s instructions. A. Flip over flaps ofTyvek ® WRB so each lays flat across jamb flashing, thentrim 1”-2” from the window opening using shears so as not to damage the StraightFlash™ B. Cut two pieces of DuPont™ StraightFlash™ or DuPont™ Flashing Tape* for jamb below. flashing extending 1” above window head flange and 4” to 6” below bottom edge of sill flashing. Remove release paper and press tightly along sides of window frame. B. Starting at the bottom of the window, install 4” StraightFlash™ along the angled cut in in the Tyvek® WRB. (See Special Consideration for when 3” DuPont™ Tyvek® Tape C. Cut a piece of StraightFlash™ or DuPont™ Flashing Tape* for head flashing, which is allowed.) extends beyond outer edges of jamb flashings. Remove release paper and install completely covering mounting flange and adhering to exposed sheathing or C. Install 4” StraightFlash™ along the jamb flaps. framing members. D. Repeat on other side of window.

NOTE: For high performance designs or areas of extreme exposure use 4” StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the jamb flap and perimeter of window.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 63 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method B)

Interior A B

C

STEP 11 STEP 12 A. Flip down upper flap ofTyvek ® WRB so it lays flat across head flashing, thentrim A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ 1”-2” above the window opening. Window and Door Polyurethane Foam Sealant on window interior to resist air and water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane B. Tape along all cuts in Tyvek® WRB and tape across head of the window with 3” Foam Sealant in perimeter openings less than ½”, apply using the plastic extension DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ StraightFlash™. (See tip for the Great Stuff Pro™ Dispenser Gun during installation. Special Considerations for when 3” Tyvek® Tape is allowed.) NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures C. Install DuPont™ Tyvek® Wrap Cap Fasteners or recommended fasteners at (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance appropriate spacing at head. of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff NOTE: For high performance designs or areas of extreme exposure use 4” Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant StraightFlash™ to seal the head flap and install additional mechanical fasteners through should be installed over the foam between the window frame and rough opening around the flashing at the head flap and perimeter of window. the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 64 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method C)

Method applies to following products: DuPont™ StraightFlash™, DuPont™ FlexWrap™ and DuPont™ Flashing Tape

STEP 1 STEP 2 A. Cut rough opening in sheathing for window. Ensure that sheathing is cut flush with, A. Wrap wall as shown in DuPont™ Tyvek® Mechanically-Fastened Water-Resistive and or slightly below the sill framing to allow for positive drainage. Air Barrier (WRB) Installation Guidelines for Buildings Greater Than 4 Stories that can be found at building.dupont.com. Do not install fasteners within 6” of the sills and jambs of the openings and within 9” of the head of the openings.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 65 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method C)

8“ minimum

A

B

8“ minimum A B

C

STEP 3 STEP 4 Prepare the Tyvek® WRB for window installation. A. Flip the head flap up to expose the sheathing and temporarily secure with DuPont™ Tyvek® Tape. A. Make an “I-Cut” in the Tyvek® WRB. For an “I-Cut” begin with a horizontal cut across the bottom and the top of the window frame (for round top windows, cut from the B. Flip the flaps to the side to expose the sheathing and temporarily secure with center cut straight down to the sill. Tyvek® Tape. B. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation. C. Cut two 45° slits extending from the bottom corner up and away from the window opening to expose 6”-8” of sheathing. This will create a flap at each jamb to allow for jamb flashing installation.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 66 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method C)

Wide release paper Narrow release paper

DO NOT STRETCH

C

6” A Release paper for backdam B A No gap in corner Fold to break scores B OPTIONAL BACKDAM DETAIL WHEN USING Window jamb 9” WIDE DUPONT™ FLEXWRAP™ DuPont™ FlexWrap™ Sill width +12”

WRONG Sill CORRECT

FRONT VIEW CORNER DETAIL

STEP 5 STEP 6 A. Cut DuPont™ FlexWrap™ at least 12” LONGER than width of rough opening sill (S). A. Remove wide piece of release paper. Position on horizontal sill by aligning the Use roll widths sufficient to achieve a minimum of 1” adhesionBEYOND where the inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” of window frame will be located, ensuring 2”– 3” adhesion onto the face of the wall. the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up each jamb. Adhere into rough opening. B. Inspect installation surface to ensure surface is free of dirt or substances that could interfere with adhesion as well as any sharp protrusions. Optional Back Dam: Fold 9” FlexWrap™ to break perforation. Remove center piece of release paper. Cover horizontal sill to accommodate back dam as appropriate, and C. Starting at the bottom corner, apply DuPont™ Adhesive/Primer or recommended adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” primer to exposed sheathing at least 6” up the jamb. release paper on FlexWrap™ inside rough opening to finish back dam after window installation. B. Remove narrow release paper.

DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 67 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method C)

Interior

C A

B A

A

STEP 7 STEP 8 A. Fan out the DuPont™ FlexWrap™ at corners and adhere onto face of wall. Continue A. Fold side flaps into rough opening, cut excess flaps, and secure secure with 3” adhering onto face of wall along sill. Coverage of FlexWrap™ should be 2”– 3” onto DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ StraightFlash™. the face of the wall. B. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles and bubbles by smoothing surface and repositioning as necessary. C. Apply continuous bead of sealant to wall at the window jambs.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 68 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method C)

B

D A B A

C

A

C

STEP 9 STEP 10 A. Starting at the bottom of the window, install 4” DuPont™ StraightFlash™ or DuPont™ A. Install window according to manufacturer’s instructions. ® Flashing Tape* along the angled cut in in the Tyvek WRB. B. Apply DuPont™ Adhesive/Primer or recommended primer to exposed sheathing at B. Apply continuous bead of sealant at the window head and jambs to wall or back jambs and head. side of window mounting flange.Do not apply continuous sealant bead across C. Cut two pieces of DuPont™ StraightFlash™ or DuPont™ Flashing Tape* for jamb bottom sill flange to allow for drainage. If sealant is applied to the sill, ensure that flashing extending 1” above window head flange and 4” to 6” below bottom edge of there are at least two (2) 2” gaps in the sealant bead for every 4’ of window to allow sill flashing. Remove release paper and press tightly along sides of window frame. for drainage. D. Cut a piece of StraightFlash™ or DuPont™ Flashing Tape* for head flashing, which extends beyond outer edges of jamb flashings. Remove release paper and install completely covering mounting flange and adhering to exposed sheathing or framing members.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 69 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Alternate Integral Flanged Window Detail Aligned with FMA/AAMA 100-12 (Method C)

Interior A C

B

STEP 11 STEP 12 A. Flip down upper flap ofTyvek ® WRB so it lays flat across head flashing, then trim A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ 1”-2” above the window opening. Window and Door Polyurethane Foam Sealant on window interior to resist air and water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane B. Tape along all cuts in Tyvek® WRB and tape across head of the window with 3” Foam Sealant in perimeter openings less than ½”, apply using the plastic extension DuPont™ Tyvek® Tape, DuPont™ Flashing Tape* or 4” DuPont™ StraightFlash™. (See tip for the Great Stuff Pro™ Dispenser Gun during installation. Special Considerations for when 3” Tyvek® Tape is allowed.) NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures C. Install DuPont™ Tyvek® Wrap Cap Fasteners or recommended fasteners at (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance appropriate spacing at head. of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff NOTE: For high performance designs or areas of extreme exposure use 4” Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant StraightFlash™ to seal the head flap and install additional mechanical fasteners through should be installed over the foam between the window frame and rough opening around the flashing at the head flap and perimeter of window. the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 70 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Brick Mold Window1,2

This installation guide can also be used for windows with field applied nailing fins.

Method applies to following products: DuPont™ VersaFlange™ and DuPont™ FlexWrap™

Exterior Exterior Interior

8“ minimum

B B

C

8“ minimum A

C

STEP 1 Prepare Tyvek® WRB for window installation: A. Make an “I-Cut” in the Tyvek® WRB (a modified I-Cut is also acceptable). For an C. Fold side flaps into rough opening, cut excess flaps, and secure. “I-Cut” begin with a horizontal cut across the bottom and the top of the window NOTE: Side flaps should cover interior facing framing stud. frame (for round top windows, cut from the center cut straight down to the sill. B. Cut two 45° slits a minimum of 8” from the corner of the header to create a flap above the rough opening to expose sheathing or framing members and to allow head flashing installation (see step 5). Flip head flap up and temporarily secure with DuPont™ Tyvek® Tape. Some windows and flashing widths may require longer slits due to window shape.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2 For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 71 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Brick Mold Window1,2

Wide release paper DO NOT STRETCH Narrow release paper

A

Release paper B for backdam B No gap in corner 6“ Fold to break scores minimum Window jamb OPTIONAL BACKDAM DETAIL WHEN USING ™ ™ DuPont™ 9” WIDE DUPONT FLEXWRAP FlexWrap™

Sill width +12” WRONG Sill CORRECT

A FRONT VIEW CORNER DETAIL

STEP 2 STEP 3 A. Cut DuPont™ FlexWrap™ at least 12” LONGER than width of rough opening sill (S). A. Remove wide piece of release paper. Position on horizontal sill by aligning the Use roll widths sufficient to achieve a minimum of 1” adhesionBEYOND where the inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” window frame will be located, ensuring 2”– 3” adhesion onto the face of the wall. of the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up each jamb. Adhere into rough opening. B. Inspect installation surface to ensure surface is free of dirt or substances that could interfere with adhesion as well as any sharp protrusions. Optional Back Dam: Fold 9” FlexWrap™ to break perforation. Remove center piece of release paper. Cover horizontal sill to accommodate back dam as appropriate, and adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” release paper on FlexWrap™ inside rough opening to finish back dam after window installation. B. Remove narrow release paper.

DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2 For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 72 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Brick Mold Window1,2

B

A

STEP 4 A. Fan out the DuPont™ FlexWrap™ at corners and adhere onto face of wall. Continue adhering onto face of wall along sill. Coverage of FlexWrap™ should be 2”– 3” onto the face of the wall. B. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles and bubbles by smoothing surface and repositioning as necessary.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2 For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 73 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Brick Mold Window1,2 Scored release Paper

DuPont VersaFlange ™ ™

™ ™

DuPont VersaFlange

DuPont™ VersaFlange™ A B D

C

F

E 45°

Window interior

Window interior

STEP 5 A. Prepare head flashing by cutting a piece ofDuPont ™ VersaFlange™ at least 12” D. Remove the inner release paper and adhere the flashing to the back of the brick LONGER than the head length. mold and the window casing.

B. Break the scored release paper on one side of the head flashing by folding it back E. At the corner of the window frame, cut the VersaFlange™ along the corner at a and forth upon itself. 45° angle.

C. Center the flashing on the window head and position so that it contacts the window F. Fold the VersaFlange™ down flat against the brick mold. frame and interior side of the brick mold. Remove the outer release paper and adhere the flashing to the window frame. Use the inner release paper to form a tight seal in the corner where the brick mold attaches to the window frame.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2 For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 74 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Brick Mold Window1,2

Make sure the adhesive on these pieces will 45° overlap

1” C

E 1-1/2”

A D 45° Window interior Window interior

STEP 6 A. Prepare jamb flashing by cutting a piece ofDuPont ™ VersaFlange™ at least 6” D. Remove the outer release paper and adhere the flashing to the window frame. LONGER than the jamb. Use the inner release paper to form a tight seal in the corner. B. Break the scored release paper on one side of the jamb flashing by folding it back E. Remove the inner release paper and adhere the flashing to the back of the and forth upon itself. brick mold.

C. Position so that it contacts the window frame and interior side of the brick mold. F. At the corner of the window frame, cut the VersaFlange™ along the corner and fold Ensure that the jamb flashing is positioned 1-1/2” below the top edge of the head it down flat to adhere against the head flashing. flashing. Jamb flashing adhesive must come in contact with head flashing adhesive and overlap by 1”.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2 For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 75 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Brick Mold Window1,2

D B A D C A

™ ™

DuPont

VersaFlange

DuPont VersaFlange

DuPont VersaFlange

VersaFlange VersaFlange DuPont DuPont

™ ™

Top view

™ Backer rod VersaFlange and sealant DuPont ™ ®

VersaFlange DuPont ™ DuPont Tyvek WRB ™

™ Brick mold

Window B DuPont™ VersaFlange™

C

STEP 7 STEP 8 A. Apply DuPont™ Adhesive/Primer, or recommended primer, to exposed sheathing. A. Cut a piece of metal or vinyl drip cap slightly longer than the window’s width and place a bead of sealant on the rear side. Install the drip cap tight against the B. Install window according to manufacturer’s installation instructions. window head and cover the top edge with 4” StraightFlash™. C. Remove the remaining release paper from the DuPont™ VersaFlange™ jamb flashing B. Flip down upper flap ofTyvek ® WRB so it lays flat across head flashing, then trim and press firmly to adhere it to theTyvek ® WRB. 1”-2” above the window opening. D. Remove the release paper at the head and adhere it to the wall surface. C. Tape along all cuts in Tyvek® WRB and tape across drip cap with 3” Tyvek® Tape or Optional: Cover exposed butyl with DuPont™ StraightFlash™ or DuPont™ Tyvek® Tape. 4” StraightFlash™. (See Special Considerations for when 3” Tyvek® Tape is allowed.) D. Install DuPont™ Tyvek® Wrap Cap Fasteners, or recommended fasteners according to fastening schedule.

NOTE: For high performance designs or areas of extreme exposure use 4” StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2 For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 76 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Brick Mold Window1,2

Interior

STEP 9 A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro™ Window and Door Polyurethane Foam Sealant on window interior to resist air and water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane Foam Sealant in perimeter openings less than ½”, apply using the plastic extension tip for the Great Stuff Pro™ Dispenser Gun during installation. NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant should be installed over the foam between the window frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2 For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 77 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window Using DuPont™ VersaFlange™ 1,2

While the depictions and instructions for this method refer to a non-flanged window, this method is also applicable for a non-flanged door1,2.

Method applies to following products: DuPont™ VersaFlange™, DuPont™ FlexWrap™, and DuPont™ FlexWrap™ EZ

Exterior Exterior Interior

8“ minimum

B B

8“ minimum A C

C

STEP 1 Prepare Tyvek® WRB for window installation. Do not install fasteners within 6” of the sills and jambs, and within 9” of the head of the openings.

A. Make an “I-Cut” in the Tyvek® WRB (a modified I-Cut is also acceptable). For an C. Fold side flaps into rough opening, cut excess flaps, and secure. Side flaps should “I-Cut” begin with a horizontal cut across the bottom and the top of the window cover interior facing framing stud. frame. From the center cut straight down to the sill.

B. Cut two 45° slits a minimum of 8” from the corner of the header to create a flap above the rough opening to expose sheathing or framing members and to allow head flashing installation (see step 5). Flip head flap up and temporarily secure with DuPont™ Tyvek® Tape. Some windows and flashing widths may require longer slits.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 78 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window Using DuPont™ VersaFlange™ 1,2

Wide release paper DO NOT STRETCH Narrow release paper

A

Release paper for backdam B B No gap in corner Fold to break scores 6“ minimum Window jamb OPTIONAL BACKDAM DETAIL WHEN USING 9” WIDE DUPONT™ FLEXWRAP™ DuPont™ FlexWrap™

Sill width +12” WRONG Sill CORRECT

A FRONT VIEW CORNER DETAIL

STEP 2 STEP 3 A. Cut DuPont™ FlexWrap™ at least 12” LONGER than width of rough opening sill (S). A. Remove wide piece of release paper. Position on horizontal sill by aligning the Use roll widths sufficient to achieve a minimum of 1” adhesionBEYOND where the inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” window frame will be located, ensuring 2”– 3” adhesion onto the face of the wall. of the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up each jamb. Adhere into rough opening. B. Inspect installation surface to ensure surface is free of dirt or substances that could interfere with adhesion as well as any sharp protrusions. Optional Back Dam:Fold 9” FlexWrap™ to break perforation. Remove center piece of release paper. Cover horizontal sill to accommodate back dam as appropriate, and adhere into rough opening along sill and up jambs (min 6” on each side). Leave 1” release paper on FlexWrap™ inside rough opening to finish back dam after window installation. B. Remove narrow release paper.

DO NOT STRETCH MATERIAL ALONG THE SILL OR JAMBS.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 79 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window Using DuPont™ VersaFlange™ 1,2

B

A

STEP 4 A. Fan out the DuPont™ FlexWrap™ at corners and adhere onto face of wall. Continue adhering onto face of wall along sill. Coverage of FlexWrap™ should be 2”– 3” onto the face of the wall. B. Firmly press sill flashing to ensure full adhesion on all surfaces. Eliminate wrinkles and bubbles by smoothing surface and repositioning as necessary.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 80 Scored release paper

DuPont VersaFlange ™ ™

™ ™

DuPont VersaFlange

DuPont™ VersaFlange™

Top View DuPont™ Tyvek® WRB Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed ™ ™ 1,2 Non-Flanged Window Using DuPont VersaFlange Window DuPont™ VersaFlange™

Scored release paper

A F DuPont B VersaFlange ™ D ™

™ ™

DuPont VersaFlange C

E ™ ™ DuPont VersaFlange 45°

Top View DuPont™ Tyvek® WRB

Window ™ ™ DuPont VersaFlange Window interior

Window interior

STEP 5 A. Prepare head flashing by cutting a piece of ™ ™ at least 12” D. Remove the inner release paper and adhere the flashing to the back of the DuPont VersaFlange F LONGER than the head length. Before flashing, prime window fins and casings with aluminum window fin and casing. DuPont™ Adhesive/Primer or recommended primer. E. At the corner of the window frame, cut the VersaFlange™ along the corner at a B. Break the scored release paper on one side of the head flashing by folding it back 45° angle. E and forth upon itself. F. Fold the45° VersaFlange™ down flat. C. Center the flashing on the window head and position so that it contacts the window frame and interior side of the front flange. Remove the outer release paper and adhere the flashing to the window frame. Use the inner release paper to form a tight seal in the corner. Window interior

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 81 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window Using DuPont™ VersaFlange™ 1,2

Make sure the adhesive on these pieces will overlap 45° 1” G C F

G E 1-1/2”

A D

Window interior F 45° Window interior

STEP 6 A. Prepare jamb flashing by cutting a piece ofDuPont ™ VersaFlange™ at least 6” D. Remove the outer release paper and adhere the flashing to the window frame. Use LONGER than the jamb. the inner release paper to form a tight seal in the corner. B. Break the scored release paper on one side of the jamb flashing by folding it back E. Remove the inner release paper and adhere the flashing to the back of the and forth upon itself. aluminum window fin.

C. Position the flashing so that it contacts the window frame and interior side of the F. At the corner of the window frame, cut the VersaFlange™ along the corner and fold aluminum window fin. Ensure that the jamb flashing is positioned 1-1/2 inch below it down flat to adhere against the head flashing. the top edge of the head flashing. Jamb flashing adhesive must come in contact G. Cut a 2” x 4” piece of DuPont™ FlexWrap™ or a 4” piece of DuPont™ FlexWrap™ EZ with head flashing adhesive and overlap by 1”. and patch each corner.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 82 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window Using DuPont™ VersaFlange™ 1,2

DuPont™ StraightFlash™ Butyl adhesive

D

A

™ 10” ™

DuPont

VersaFlange

™ DuPont VersaFlange

VersaFlange DuPont

™ Peel off release paper B and attach to underside of window

C

High pressure skirt (optional – see next step Bend for assembly)

STEP 7 STEP 7 – OPTIONAL HIGH-PRESSURE SKIRT A. Apply DuPont™ Adhesive/Primer or recommended primer to the top of the jambs A. Create the high-pressure skirt by cutting a piece of Tyvek® WRB 1” wider than the and exposed sheathing. width of window opening and approximately 10” in depth.

B. Install window according to manufacturer’s installation instructions. If sealant is B. Attach skirt to underside of window using a piece of VersaFlange™ or 4” applied to the sill, ensure that there are at least two (2) 2” gaps in the sealant bead StraightFlash™ cut to the same width as the skirt. for every 4’ of window to allow for drainage.

C. Remove the remaining release paper from the DuPont™ VersaFlange™ jamb flashing and press firmly to adhere it to theTyvek ® WRB. D. Remove the release paper at the head and adhere it to the wall surface. 1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Optional: Cover exposed butyl with DuPont™ StraightFlash™ or DuPont™ Tyvek® Tape. Building Code. 2For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 83 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window Using DuPont™ VersaFlange™ 1,2

A Top View C

B ™ ®

A DuPont Tyvek WRB

™ ™ Window

™ ™ ™

DuPont VersaFlange DuPont VersaFlange

VersaFlange DuPont

DuPont VersaFlange VersaFlange DuPont

STEP 8 STEP 9 ® A. Cut a piece of metal or vinyl drip cap slightly longer than the window’s width and A. Flip down upper flap ofTyvek WRB so it lays flat across head flashing, then trim place a bead of recommended sealant on the rear side. Install the drip cap tight 1”-2” above the window opening. against the window head and cover the top edge with DuPont™ StraightFlash™ or B. Tape along all cuts in Tyvek® WRB and tape across drip cap with 3” Tyvek® Tape or DuPont™ Tyvek® Tape. 4” StraightFlash™. (See Special Considerations for when 3” Tyvek® Tape is allowed.) C. Install DuPont™ Tyvek® Wrap Cap Fasteners or recommended fasteners at jambs and head flap according to fastening schedule.

NOTE: For high performance designs or areas of extreme exposure use 4” StraightFlash™ to seal the head flap and install additional mechanical fasteners through the flashing at the head flap and perimeter of window.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 84 Installation Methods for DuPont Self-Adhered Flashing Products AFTER the DuPont™ Tyvek® WRB is Installed Non-Flanged Window Using DuPont™ VersaFlange™ 1,2

Interior

A

B

STEP 10 STEP 11

™ For High-Pressure Skirt Installations A. Create a continuous perimeter seal using backer rod and sealant or Great Stuff Pro A. Install DuPont™ Tyvek® Wrap Cap Fasteners through the skirt. Window and Door Polyurethane Foam Sealant on window interior to resist air and water infiltration. When usingGreat Stuff Pro™ Window and Door Polyurethane ® ™ ™ B. Secure sides of high-pressure skirt to the Tyvek WRB with DuPont StraightFlash Foam Sealant in perimeter openings less than ½”, apply using the plastic extension ™ ® ™ and skip tape bottom with 3” DuPont Tyvek Tape or 4” StraightFlash . Skip taping tip for the Great Stuff Pro™ Dispenser Gun during installation. provides weeps that allows drainage behind the skirt. NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam. Sealant should be installed over the foam between the window frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window and Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging the DuPont Self-Adhered Flashing Product or DuPont™ Tyvek® WRB.

1 For Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code. 2For smooth-framed window installations not exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 85 Installation Method for Installing DuPont Self-Adhered Flashing Products BEFORE DuPont™ Tyvek® WRB Non-Flanged or Integral Flanged Window

Installation of Tyvek® WRB frame around window rough opening prior to window installation is necessary for proper shingling and integration with the Tyvek® WRB when it is installed after the window. The method shown here is installation of a non-flanged window but may be applied to all the flashing methods included in this installation guideline.

D B 16“min. 8“min.

C 14“min. Rough Opening

A

8“min. No Fasteners in This Area

STEP 1 Install Tyvek® WRB Frame Around Window Rough Opening NOTE: Use standard I-cut per the applicable section of these installation guides when installing an integral flanged window. A. Cut a piece of Tyvek® WRB that is 32” wider and 32” taller than the window rough opening to allow a 12" width around all sides. D. Cut a head flap at a 45° angle to expose 8” of sheathing to allow for head flashing installation. B. Center the piece of Tyvek® WRB over the rough opening and fasten along the sides and across the top using DuPont™ Tyvek® Wrap Caps or recommended fasteners. Fasteners should not be installed within 14" of the edge of the rough opening, and no fasteners should be installed within 8" of the bottom edge of the Tyvek® WRB. C. Cut an opening in the Tyvek® WRB using a square cut around the perimeter of the rough opening to create a frame around the window (ensure that the Tyvek® WRB frame is cut flush with the sheathing and is not wrapped into the rough opening).

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 86 Installation Method for Installing DuPont Self-Adhered Flashing Products BEFORE DuPont™ Tyvek® WRB Non-Flanged or Integral Flanged Window

Interior

STEP 2 STEP 3 Install Window Per Applicable Method Based on Window Type A. Install sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use Great Stuff Pro™ Window & Door Polyurethane A. Follow the applicable instructions in these install guidelines to prepare the window Foam Sealant, or recommended foam. When using Great Stuff Pro™ Window & rough opening accordingly and install window. Door Polyurethane Foam Sealant in perimeter openings less than ½”, apply using the plastic extension tip for the Great Stuff Pro™ Dispenser Gun during installation. NOTE: For high performance installations exceeding ASTM E1677 wind loading pressures (10.8 psf, 65 mph equivalent structural load) and ASTM E331 water infiltration resistance of 6.24 psf, it is necessary to install sealant over the cured foam when using Great Stuff Pro™ or other recommended foam. Sealant should be installed over the foam between the window frame and rough opening around the entire interior perimeter. If Great Stuff Pro™ Window & Door Polyurethane Foam Sealant or other recommended foam extends beyond the window frame, shave the excess cured foam flush with the window frame before applying sealant. Avoid damaging theDuPont Self-Adhered Flashing or Tyvek® WRB.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 87 Installation Method for Installing DuPont Self-Adhered Flashing Products BEFORE DuPont™ Tyvek® WRB Non-Flanged or Integral Flanged Window

F 10“ 8“

10“ 8“

Rough Opening Rough Opening 10“ 8“ ✃ D C

8“ E B No Fasteners Area D A

STEP 4 Install and Integrate the Tyvek® WRB A. Install the Tyvek® WRB according to the DuPont™ Tyvek® Mechanically-Fastened D. Create 6" horizontal slits in the Tyvek® WRB at each lower corner of the perimeter cut. Water-Resistive and Air Barrier (WRB) Installation Guidelines for Buildings Greater E. Bring the bottom portion of the Tyvek® WRB frame through the slits so it laps over Than 4 Stories that can be found at building.dupont.com. Do not install fasteners the top layer of Tyvek® WRB. within 10" of the rough opening along jambs and head and within 12" along the sill. F. Tape seams at bottom, sides, and top of rough opening using 3” DuPont™ Tyvek® Tape. B. Mark a perimeter box 8" away from the rough opening sill, jambs and head. NOTE: 3” Tyvek® Tape can be used to seal Tyvek® WRB-to-Tyvek® WRB seams. If the cut C. Cut the Tyvek® WRB along perimeter marking to expose window and Tyvek® WRB edges of the Tyvek® WRB are positioned over the window flashing, theTyvek ® WRB must frame below. Do not cut Tyvek® WRB frame underneath. be terminated around the perimeter of the window (jambs and head) with another layer of DuPont™ StraightFlash™.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 88 Hybrid Condition – DuPont™ Tyvek® WRB Terminated with DuPont™ StraightFlash™ and/or DuPont™ FlexWrap™ and Integrated with DuPont™ Tyvek® Fluid Applied Products

Complex wall and window flashing conditions may require the use of Tyvek® Fluid Applied Products for part of a wall or window and/or door flashing. While there are many variations of this condition, it is important to properly integrate the Tyvek® WRB with the Tyvek® Fluid Applied Products using StraightFlash™ and FlexWrap™. The following example shows a recessed wall plane treated with DuPont™ Tyvek® Fluid Applied WB+™ with a window flashed withTyvek ® Fluid Applied Products and integrated with the Tyvek® WRB on the face of the wall. Refer to the DuPont™ Tyvek® Fluid Applied Flashing Installation Guidelines for more information.

D

C A

8”

B

D

STEP 1 A. Install Tyvek® WRB on wall per DuPont™ Tyvek® Mechanically-Fastened Water- C. Cut a flap at top of recessed wall plane at a 45° angle to expose 8” of sheathing to allow Resistive and Air Barrier (WRB) Installation Guidelines for Buildings Greater Than 4 for installation of transition flashing in Step 4. Flip up to expose the sheathing and Stories that can be found at building.dupont.com. Do not install fasteners within 6” of temporarily secure flap withDuPont ™ Tyvek® Tape.. the bottom and sides of the openings and within 9” of the top of the recessed wall. D. Temporarily secure Tyvek® WRB with Tyvek® Tape at perimeter of recessed wall B. Cut along perimeter of recessed wall plane. plane to facilitate transition flashing installation.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 89 Hybrid Condition – DuPont™ Tyvek® WRB Terminated with DuPont™ StraightFlash™ and/or DuPont™ FlexWrap™ and Integrated with DuPont™ Tyvek® Fluid Applied Products

C

2” B min.

A

6”

A Plane (H)

2”– 3” Height of Recess Wall Height of Recess Wall

C B Width of Recess Wall (W) + 12”

STEP 2 STEP 3 A. Cut the FlexWrap™ at least 12” LONGER than width of recessed wall plane (W). A. Cut (2) pieces of StraightFlash™ the height of the recessed wall plane (H) or long enough to overlap the bottom of recessed wall flashing by at least 2” and be B. Remove wide piece of release paper and adhere on horizontal ledge by aligning overlapped by future top of recess wall flashing by at least 2”. the inside edge of the narrow release paper with the face of the wall to ensure 2”– 3” of the FlexWrap™ will be adhered to the face of the wall with a minimum of 6” up B. Terminate the Tyvek® WRB along each side of recessed wall, ensuring the each side. StraightFlash™ extends 2” onto the face of the wall and 2” into the recess.

C. Remove narrow piece of release paper. Fan out the FlexWrap™ at corners and C. Apply DuPont™ Adhesive/Primer or recommended primer to the top of the adhere onto face of wall. Continue adhering onto face of wall along sill. Coverage of recessed wall plane and exposed sheathing. FlexWrap™ should be 2”– 3” onto the face of the wall.*

*A 3-piece transition flashing method can also be used withStraightFlash ™ in combination with FlexWrap™ corners. The StraightFlash™ in installed the width of the bottom or top of recessed wall plane prior to placing the FlexWrap™ corners. The FlexWrap™ corners should be at least 12” long allowing for 6” overlap onto the StraightFlash™ at bottom, top, and sides of recessed wall plane.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 90 Hybrid Condition – DuPont™ Tyvek® WRB Terminated with DuPont™ StraightFlash™ and/or DuPont™ FlexWrap™ and Integrated with DuPont™ Tyvek® Fluid Applied Products

B

C

A A

C

A

1”– 2”

STEP 4 STEP 5 A. Install FlexWrap™ at top of recess wall using method shown in Step 2.* A. Flip down Tyvek® WRB flap and trim 1”- 2” above top edge of recessed wall plane. B. Terminate flap along the top of the recessed wall plane and along diagonal seams with 3” DuPont™ Tyvek® Tape or 4” StraightFlash™ (see Special Considerations for when 3” Tyvek® Tape is allowed).

C. For high performance designs or areas of extreme exposure use 4” StraightFlash™ to seal the flap and installDuPont ™ Tyvek® Wrap Cap Fasteners, or recommended fasteners, at the flap and perimeter of the recessed wall plane.

*A 3-piece transition flashing method can also be used withStraightFlash ™ in combination with FlexWrap™ corners. The StraightFlash™ in installed the width of the bottom or top of recessed wall plane prior to placing the FlexWrap™ corners. The FlexWrap™ corners should be at least 12” long allowing for 6” overlap onto the StraightFlash™ at bottom, top, and sides of recessed wall plane.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 91 Hybrid Condition – DuPont™ Tyvek® WRB Terminated with DuPont™ StraightFlash™ and/or DuPont™ FlexWrap™ and Integrated with DuPont™ Tyvek® Fluid Applied Products

A

B

STEP 6 A. Install DuPont™ Tyvek® Fluid Applied Flashing and Joint Compound+ and/or DuPont Self-Adhered Flashing Products and window per the DuPont™ Tyvek® Fluid Applied Flashing Installation Guidelines.

NOTE: Window/flashing installation sequence will vary by project and window type. All installations must allow for drainage at window sill.

B. Install DuPont™ Tyvek® Fluid Applied WB+™ per the DuPont™ Tyvek® Fluid Applied WB+™ Wall and Substrate Guidelines. Overlap the Tyvek® Fluid Applied WB+™ onto the StraightFlash™ and FlexWrap™ at recess wall transition by a minimum of 2”.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 92 Installation Methods for DuPont™ Tyvek® WRB Interfaces with Through Wall Flashing

Base of wall Shelf angle

6”

6” C D B C

A A 6” Through wall B flashing

Lap DuPont™ Tyvek® WRB 6”over through wall flashing DuPont™ StraightFlash™

A. Install through wall flashing on the vertical wall per plans and specifications. A. Through wall flashing should be applied to the top of the shelf angle and theTyvek ® The through wall flashing may be terminated by using a reglet, counterflashing, WRB should be properly shingled over by at least 6”. termination bar or by embedding in a mortar joint. B. Seal the Tyvek® WRB to the bottom of the shelf angle using DuPont™ StraightFlash™. B. Overlap through wall flashing withTyvek ® WRB by 6”. C. Seal bottom of the Tyvek® WRB to through wall flashing using 3”Tyvek ® Tape or a C. Mechanically fasten bottom of Tyvek® WRB through top of through wall flashing. DuPont Self-Adhered Flashing Product. D. Seal vertical and horizontal seams using 3” DuPont™ Tyvek® Tape or DuPont Self- Adhered Flashing Product. NOTE: For high performance designs or areas of extreme exposure install additional mechanical fasteners through the Tyvek® WRB terminated at the base of wall. Use appropriate fastener for each substrate.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 93 Installation Methods for DuPont™ Tyvek® WRB Interfaces with Through Wall Flashing

Parapet wall with brick

D C

B

A

4”

A. Apply DuPont™ Adhesive/Primer or recommended primer to wall surface or sheathing and install a minimum 4” DuPont™ StraightFlash™. B. Install roofing membrane

C. Install through wall flashing over parapet wall, overlapping theTyvek ® WRB and the roofing membrane by a minimum of 4” in the proper shingling manner. D. Install coping cap.

NOTE: Additional CAD details are available in the Technical Information section of building.dupont.com.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 94 Penetrations

Seal around plumbing pipes, HVAC components, electrical outlets, exterior lights, Tape to overlap the top edge of the DuPont Self-Adhered Flashing Product (shown flashing panels, and other objects that penetrate theDuPont ™ Tyvek® WRB. Always below). use positive shingling by installing Tyvek® WRBs and DuPont Self-Adhered Flashing OPTIONAL INTERIOR SEAL: The penetration rough opening can be sealed from the Products from bottom to top, with upper layer installed over lower layer. Optional last interior side using sealant (and backer rod as necessary), or Great Stuff Pro™ Window & step for all installations: Install a piece of Tyvek® WRB and seal with DuPont™ Tyvek® Door Polyurethane Foam Sealant, Great Stuff Pro™ Gaps & Cracks Polyurethane Foam Sealant, or recommended foam. Flashing Integral Flanged Products AFTER Installation of Tyvek® WRB

STEP 1 STEP 2 STEP 3 STEP 4 (OPTIONAL) Install Tyvek® WRB and cut as necessary to Install integral flanged product per Install DuPont™ StraightFlash™ or DuPont™ Install a piece of Tyvek® WRB to overlap the accommodate integral flanged product. manufacturer’s instructions. Flashing Tape* onto flanges, extending onto top edge of the StraightFlash™. Seal sides and Tyvek® WRB by a minimum of 2”. top with Tyvek® Tape

Method 2

W+1”

W 2”

STEP 1 STEP 2 STEP 3 STEP 4 Install Tyvek® WRB and make horizontal cut a Slide top flange into slit with minimum Adhere DuPont Self-Adhered Flashing Product Install DuPont Self-Adhered Flashing Product minimum of 1” wider than flange. 2” overlap of Tyvek® WRB, and install per onto bottom and side flanges, extending onto to top flange, extending beyondDuPont Self- manufacturer’s instructions. Tyvek® WRB by 2”. Adhered Flashing Product on side flanges.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 95 Penetrations

Option 1: Flashing Non-Flanged AFTER Installation of DuPont™ Tyvek® WRB Using DuPont™ FlexWrap™ EZ For non-flanged products with OD GREATER than 2”

RO

OD ™ t n o P u D Start

N

O I

T C E IR D P A 1” R W

Use DuPont™ FlexWrap™ EZ only when penetration rough opening (RO) is not more STEP 1 STEP 2 than ½“ larger than the outside diameter/ Install Tyvek® WRB over non-flanged product Cut a piece of FlexWrap™ EZ longer than dimension (OD) of non-flanged product. and cut around penetration. circumference of non-flanged product to ® NOTE: For more information regarding ensure a minimum 1” overlap onto the Tyvek the installation of FlexWrap™ EZ, refer to WRB. Starting at the horizontal position on the Installation Information Bulletin for either side, adhere around penetration and ® FlexWrap™ EZ. onto Tyvek WRB.

For non-flanged products with OD LESS than 2”

F

l

e x

W

r Z ap™ E 1” 1”

STEP 1 STEP 2 STEP 3 Install Tyvek® WRB over non-flanged product Cut a piece of FlexWrap™ EZ the length of ½ Cut a second piece of FlexWrap™ EZ the and cut around penetration. the circumference of the non-flanged product. length of the pipe circumference. Adhere Adhere onto bottom section and fan out onto onto top section and fan out onto face of wall Tyvek® WRB. with a minimum of 1” overlap of the edges of FlexWrap™ EZ below.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 96 Penetrations

Option 2: Flashing Non-Flanged Products AFTER Installation of DuPont™ Tyvek® WRB Using DuPont™ FlexWrap™

™ p a r W

x

t e

n

l

o

P

u

F D

2”

STEP 1 STEP 2 Install Tyvek® WRB over non-flanged product Working counterclockwise, install DuPont™ and cut around penetration. FlexWrap™ around penetration with a minimum 2” overlap.

Flashing Integral Flanged Products BEFORE Installation of Tyvek® WRB

2” ✃

STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 Install integral flanged product Prime as necessary with DuPont™ Install Tyvek® WRB. Make cut in Tyvek® WRB, ensuring a Seal edges of Tyvek® WRB with onto sheathing per manufacturer’s Adhesive/Primer. Install DuPont™ minimum of 2” gap for adhesion of StraightFlash™. instructions. StraightFlash™ or DuPont™ Flashing StraightFlash™. Tape* onto flanges, extending onto sheathing by a minimum of 2”.

*DuPont™ Flashing Tape is only permitted for Residential-Use building structures. Residential-Use (Group R) is defined by the 2015/2018 International Building Code.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 97 Product Composition and Design Considerations and doors, and appropriate flashing will melt at temperatures greater than materials paying attention to proper 250°F (121°C). DuPont Self-Adhered UV Stability When installed in conjunction with installation of each component. Flashing Products are combustible and ™ ® other building materials, Tyvek® WRBs, DuPont Tyvek WRBs used in should be protected from flames and DuPont Self-Adhered Flashing Products, In a system where no exterior sheathing construction products are made from other high heat sources. DuPont Self- and Tyvek® Fluid Applied Products is used and Tyvek® WRBs are installed 100% flash spunbonded high density Adhered Flashing Products will not must be properly shingled with these directly over the wall studs, exterior fibers which have been support combustion if the heat source materials such that water is diverted to facade materials should be selected to bonded together by heat and pressure, is removed. However, if burning occurs, the exterior of the wall system. Tyvek® ensure maximum protection against without binders or fillers, into a tough ignited droplets may fall away from the WRBs and Tyvek® Fluid Applied WB+™ water intrusion. Careful workmanship and durable sheet structure. Additives point of ignition. For more information, are secondary weather barriers. The proper installation of each component is have been incorporated into the call 1-833-338-7668. polyethylene to provide ultraviolet light outer facade is the primary barrier. very important. ™ Follow facade manufacturer’s installation Tyvek® Fluid Applied Products may cause resistance. DuPont requires that DuPont Depending on job site conditions, it is ® ® ® and maintenance requirements for all irritation. Repeated or prolonged skin Tyvek CommercialWrap and Tyvek possible that stains may appear, but will ® facade systems in order to maintain contact may cause allergic reactions with CommercialWrap D be covered within not alter performance of the Tyvek® Fluid water holdout properties and ensure susceptible persons. May cause irritation 9 months (270 days) of installation. Applied Product. performance of Tyvek® WRBs and Tyvek® of respiratory tract. This product is a DuPont Self-Adhered Flashing Products Fluid Applied WB+™. Do not install on a mixture. Health Hazard information is are made from a synthetic rubber wall that does not feature a continuous Safety and Handling based on its components. Refer to Safety adhesive and a laminate of polyethylene path for moisture drainage. Any standing Warning Data Sheet (SDS) for further information. film, polypropelene film, elastic fiber, water must be allowed to drain off the Tyvek® WRBs are slippery and should not synthetic rubber adhesive, polyurethane KEEP OUT OF REACH OF CHILDREN. membrane. Follow facade manufacturer’s be used in any application where they adhesive, and a top sheet of flash installation and maintenance will be walked on. In addition, because Children can fall in to bucket and drown. spunbonded high density polyethylene requirements for all facade systems they are slippery, DuPont recommends Keep children away from bucket with fibers or polypropelene film. Additives in order to maintain water holdout using kickjacks, scaffolding, or lifts for even a small amount of liquid. have been incorporated into these properties and ensure performance exterior work above the first floor. If Use only as directed. Avoid inhalation of materials to provide ultraviolet light of DuPont™ Tyvek® WRBs and Tyvek® ™ ladders must be used, extra caution resistance. DuPont requires that DuPont ™ vapor aerosol. Fluid Applied WB+ . Use of additives, must be taken to use them safely by FlexWrap™, DuPont™ FlexWrap™ EZ, or cleansers on or in the facade following the requirements set forth in Caution DuPont™ StraightFlash™ and DuPont™ system may impact the performance of ® ™ ANSI Standards 14.1, 14.2, and 14.5 for Obtain special instructions for Tyvek VersaFlange be covered within nine ™ ® ® DuPont Tyvek WRBs and Tyvek Fluid ladders made of wood, aluminum, and Fluid Applied Products before use. Do months (270 days) of installation. DuPont ™ Applied WB+ . DuPont Building Envelope fiberglass, respectively. DuPont™ Tyvek® not handle until all safety precautions requires that DuPont™ Flashing Tape be Solutions Products are to be used as is combustible and should be protected have been read and understood. Avoid covered within 4 months (120 days) of outlined in this installation guideline. from flames and other high heat sources. breathing dust/fumes/gas/mist/vapors/ installation. DuPont Self-Adhered Flashing and DuPont™ Tyvek® will melt at 275°F (135°C) spray. Vapor and aerosols are harmful if ® DuPont™ Tyvek® Fluid Applied Products Tyvek Flashing and Joint Compound+ and if the temperature of DuPont™ Tyvek® using spray application. Use in a well- are formulated to include elastomeric should only be used to seal penetrations reaches 750°F (400°C), it will burn and the ventilated area. Use NIOSH approved ® polymers that cure to a continuous, and flash openings in buildings.Tyvek fire may spread and fall away from the respirator. NIOSH-approved particulate ® fully-adhered, tough, durable membrane. WRBs, Tyvek Fluid Applied Products, and point of ignition. For more information, filtering full-face respirator with a P95 Additives have been incorporated to DuPont Self-Adhered Flashing Products call 1-833-338-7668. particulate filter or half-mask respirator provide ultraviolet light resistance. are not to be used in roofing applications. with a P95 particulate filter and splash DuPont Self-Adhered Flashing Products DuPont requires that the DuPont™ For superior protection against bulk water impact goggles when spraying. NIOSH- and their release paper are slippery and Tyvek® Fluid Applied WB+™ and DuPont™ penetration, DuPont suggests a system approved N95 disposable safety mask should not be walked on. Remove release Tyvek® Fluid Applied Flashing and Joint combining a quality exterior facade, a with splash impact goggles for manual paper from work area immediately. Compound+ are to be covered within good secondary air and water barrier and application such as troweling or rolling, DuPont Self-Adhered Flashing Products 9 months (270 days) of installation. exterior sheathing, high quality windows © 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 98 and for clean-up. If vapors are inhaled, Great Stuff Pro™ polyurethane foam Hazard Statement immediately move from exposure to fresh sealant and adhesive products contain Tyvek® Fluid Applied Products may cause air and contact a physician. Contaminated isocyanate and a flammable blowing an allergic skin reaction. May cause work clothing should not be allowed out agent. Read all instructions and (Material) serious eye damage. May cause genetic of the workplace. Wear protective gloves/ Safety Data Sheet ((M)SDS), carefully defects. May damage fertility or the protective clothing/eye protection/face before use. Eliminate all sources of unborn child. As it relates to California protection. IF ON SKIN: Wash with plenty ignition before use. Cover all skin. Wear Prop 65, Tyvek® Fluid Applied Products of soap and water. IF IN EYES: Rinse long sleeves, gloves, and safety or can expose you to substances including cautiously with water for several minutes. goggles. Not for use in aviation, or food/ Crystalline silica, which is /are known to Remove contact lenses, if present and beverage contact, or as structural support the State of California to cause cancer. For easy to do. Continue rinsing. IF exposed or in marine applications. Provide adequate more information, visit concerned: Get medical advice/attention. ventilation or wear proper respiratory p65Warnings.ca.gov. Immediately call a POISON CENTER/ protection. Contents under pressure. Not doctor. If skin irritation or rash occurs: to be used for filling closed cavities or For complete warranty information Get medical advice/ attention. Wash voids such as behind walls and under please call 1-833-338-7668 or visit us at contaminated clothing before reuse. tub surrounds; this improper use of the building.dupont.com. Store locked up. Dispose of contents/ product could result in the accumulation to an approved waste disposal of flammable vapors and/or uncured plant. Avoid contact with eyes and skin. material. Failure to follow the warnings and instructions provided with the When cured, Great Stuff Pro™ Window product, and/or all applicable rules and & Door Polyurethane Foam Sealant is regulations, can result in injury or death. combustible and will burn if exposed to open flame or sparks from high-energy Building and/or construction practices sources. Do not expose to temperatures unrelated to building materials could above 240ºF (116ºC). For more greatly affect moisture and the potential information, consult (Material) Safety for mold formation. No material supplied Data Sheet ((M)SDS), call DuPont at by DuPont can give assurance that mold 1-866-583-2583. When air sealing will not develop in any specific system. buildings, ensure that combustion Read all instructions and (Material) Safety appliances, such as furnaces, water Data Sheet ((M)SDS) carefully before use. heaters, wood burning stoves, gas stoves and gas dryers are properly vented to the For more information, visit outside. See website: http://www.epa. greatstuffpro.com or building.dupont.com gov/iaq/homes/hip-ventilation.html. In Canada visit: http://archive.nrc- cnrc.gc.ca/eng/ibp/irc/bsi/83-house- ventilation.html.

© 2020 DuPont. All Rights Reserved. 43-D100705-enNA-0720 99 NOTICE: No freedom from any patent owned by DuPont or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries or regions. DuPont assumes no obligation or liability for the information in this document. References to “DuPont” or the “Company” mean the DuPont legal entity selling the products to Customer unless otherwise expressly noted. NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY DUPONT. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. The buyer assumes all risks as to the use of the material. Buyer’s exclusive remedy or any claim (including without limitations, negligence, strict liability, or tort) shall be limited to the refund of the purchase price of the material. Failure to strictly adhere to any recommended procedures shall release DuPont de Nemours, Inc., and its affiliates, of all liability with respect to the materials or the use thereof. The information herein is not intended for use by non-professional designers, applicators or other persons who do not purchase or utilize this product in the normal course of their business. For more information about © 2020 DuPont. DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, ℠ or ® are owned by DuPont Performance Building Solutions, affiliates of DuPont de Nemours, Inc. unless otherwise noted. please call 1-833-338-7668 or visit us at 43-D100705-enNA-0720 building.dupont.com