The Detector-Based Candela Scale and Related Photometric Calibration Procedures at NIST

Total Page:16

File Type:pdf, Size:1020Kb

The Detector-Based Candela Scale and Related Photometric Calibration Procedures at NIST ············•·········•··············•······· 89 The Detector-Based Candela Scale and Related Photometric Calibration Procedures at NIST Y. Ohno, C.L. Cromer, ].E. H~dis, and G. Eppeldauer THIS PAPER IS AN IESNA TRANSACTION. IT WAS ORIGINALLY PRESENTED AT THE 1993 IESNA ANNUAL CONFERENCE. Introduction tions, such as those for luminous intensity, illumi· Since the redefinition of the candela in 1979, na· nance, luminance, and total luminous flux, have also tiona! standards laboratories have been free to realize been drastically revised, and the absolute accuracy of the candela by use of whatever radiometric means calibrations have been significantly improved. The they found most suitable. Different national new calibration procedures developed and being laboratories1- 8 and other research facilities9•10 have developed are described here. Uncertainty statements employed various techniques to realize their lumi· in this paper follow Taylor, 15 which recommends the nous intensity scales. use of 2u values for calibrations and 1u values for most Until recently, the luminous intensity scale at the other results including the uncertainty of scales. National Institute of Standards Technology was based on a gold-point blackbody. 1 The blackbody radiation The detector-based candela scale at the gold point (1337.33 K; determined at NIST from absolute radiometric detectors12) was used to Principles calibrate a variable temperature blackbody, which Let us assume a photometer as shown in Figure I is provided the spectral radiance scale. 13 From this, the constructed, using a silicon photodiode, a V(A) filter, spectral-irradiance scale was derived.14 The luminous· intensity scale was realized through spectral irra· Photometer diance measurements of a primary reference group of candela lamps using the spectral irradiance working Ught source standards. A secondary reference group, calibrated ~ r[m) against the primary group, was used for routine ~------------------------------~ calibrations. The final uncertainty of 0.8 percent (2u) 15 contained a relatively large component due to the uncertainty in the gold-point temperature at the V(A) filter Silicon top of the chain, and additional uncertainty ac· photodiode cumulated in the long calibration chain using sources. Figure I -Geometry for the detector-based candela scale realization Recently at the Radiometric Physics Division of NIST, the candela scale has been realized using a and a precision aperture. When the absolute spectral group of absolutely calibrated photometers. Other na· responsivity s(A) (in amps/watt) of the photometer is tiona! laboratories have employed absolutely measured, the responsivity R.r (in amps/lumen) of the calibrated radiometers or photometers using either photometer for luminous flux (lm) is given by thermal detectors or self-calibrated silicon photodiodes. NIST chose calibrated silicon photo· diodes with filters to make photometers on account of 1A P(A) s(A) dA (Ailm) (1) their wide dynamic range and simplicity of operation. R-r= -------- The photometers had their relative spectral respon· Km A P(A) V(A) dA sivity matched to the spectral luminous efficiency 1 function V(A), and were calibrated against the NIST where P(A) is the spectral power distribution of light absolute spectral responsivity scale, which is currently to be measured, V(A) is the spectral luminous efficien· based on a cryogenic radiometer.16 The design, cy function, and Km is the maximum spectral efficacy characterization, and calibration of the photometers (683 lm/W). If the area S(m2) of the aperture is are described in this paper. known and the responsivity R,.1 is uniform within the The procedures of various photometric calibra· aperture opening, the responsivity R,.; of the photometer for illuminance (lx) is given by Authors' affiliation: National Institute of Standards and Technology, Radiometric Physics Division, Gaithersburg, MD. R,.; = S • R,.1 (A/Ix) (2) JOURNAL of the Illuminating Engineering Society Winter 1994 90 •···•·······•········•··•········•··········· When a photometer calibrated for R,; is used to photometers are obtained by Equations 1 and 2 for measure the illuminance from a point source, the given P(A), thus providing the illuminance scale. Using luminous intensity Iv (in candelas) of the source is the photometers, the luminous intensity of a candela given by lamp is determined from the illuminance measure· ment and the given distance r in Equation 3. This pro· (3) cedure for a candela scale realization is simpler than where r is the distance (in meters) from the light the conventional source-based method. The details of source to the aperture surface of the photometer and each calibration step are discussed below. I is the output current (amps) of the photometer. To realize the candela scale, although the principles Construction of standard photometers are simple, uncertainties in measuring each of the A group of eight photometers has been developed. quantities- and uncertainties associated with the Figure 3 depicts the photometer design. A silicon assumptions must be evaluated. Figure 2 shows the photodiode, a V(A) filter, and a precision aperture are calibration chain for the candela scale as revised by mounted in the front piece of a cylindrical housing. The photodiode is plugged into a socket with a teflon this work. A cryogenic radiometer which has recently base of low electrical conductivity. On the front side of the filter, the precision aperture is glued to a holder Absolute Cryogenic carefully machined so that its front surface (the Radiometer reference surface of the photometer) is 3.00 mm from the plane of the aperture knife edge. Abs. Spectral Res ponsivity Transfer Under this front piece, an electronic assembly con· taining a current-to-voltage converter circuit with a high sensitivity and a wide dynamic range17 is built· Spectral Response Scale in to minimize noise. The circuit has a switchable gain (Silicon Photodiodes) [AIW] setting from 104 to 10 10 or 10 11 V/A. An input equivalent noise of -1 fA is achieved at the gain set· Abs.Spectral Re sponsivity calibration 11 Aperture Area measurement ting of 10 V/A with an integration time of 1.67 s and Calculation bas ed on Candela Definition a measurement bandwidth of 0.3 Hz. This high sen· sitivity feature allows precise measurement of s(A) Illuminance Scale even in the wings of the V(}l.) curve. ( Standard Photometers) [ A/lx] Because characteristics of the filter and photodiode change with temperature, a temperature sensor is in­ Distance Measu rement stalled in the front piece of the housing to monitor the photometer temperature.ts Luminous Intensity Scale Removable aperture holder (Standard lamps) [ cd] Precision Figure 2-Calibration chain for the detector-based candela scale i1s revised by the present work 24mm been installed at NIST acts as the absolute radiometric base at the top of the chain. The radiometer, (called HACR; High Accuracy Cryogenic Radiometer), cooled by liquid helium to 5 K, works on the principles of electrical substitution. The HACR's measurement uncertainty in the calibration of a light-trapping 16 detector is 0.026 percent (2cr) at 633 nm. The ab· 63.5mmdia. solute responsivities at several laser wavelengths are transferred to the Spectral Comparator Facility (SCF), Figure 3-Photometer design where the spectral responsivity scale is realized with a light-trapping detector. It is described below. The ab· * Specific firms and trade names are identified in this paper in order to solute spectral responsivity s(A) of each photometer in adequately specify the experimental procedure. Such identification does not imply recommendation or endorsement by the National Institute of the group is determined using this spectral response Standards and Technology, nor does it imply that the materials or equip· scale. The photometric responsivities R,; of the ment identified are necessarily the best available for the purpose. Winter 1994 JOURNAL of the Illuminating Engineering Society ••••••••••••••••••••••••••••••••••••••••••••• 91 Characterization of components radii, the area was calculated by a polygonal approx­ imation. The uncertainty of this area measurement Hamamatsu* SI226 and S1227 series silicon photodiodes were used for the photometers. They was given as 0.04 percent for the larger apertures and were selected for the largest shunt resistance that the 0.1 percent (both 2a) for the smaller. The transfer gains of the current-to-voltage con­ manufacturer could provide, 2.5-7.0 GO, in order to verters in the photometers were calibrated electrically minimize noise and drift in the amplifier circuit.17 by replacing the photodiode with a computer­ The reduced infrared sensitivity of these photodiodes controlled voltage source and calibrated resistors in compared to others is advantageous for application in series. The amplifier gains were determined by a photometry. SI227-IOIOBQ photodiodes with l-cm2 linear fitting of data for many combinations of input areas were used for photometers I and 2, which current and measured output voltage. The gains so possess larger-area V(}..) filters. SI226-8BQ photodi­ determined have an uncertainty of less than 0.01 per­ odes with 0.3-cm2 areas were used for the other six cent (2a). photometers. The photodiodes were screened for their uniformity of response over their active areas. Characterization and calibration of photometers The uniformities of the photodiodes were measured After characterizing the components, the pho­ at several wavelengths using the SCF (described in the tometers were assembled as shown in Figure 3. The next section), and the maximum deviation from the photometers were characterized for overall per­ mean value was less than 0.2 percent. The temperature formance and calibrated for photometric responsivity dependence of the photodiode responsivity was also as follows. measured in a temperature-controlled housing. It was An essential part of the calibration is to determine less than 0.03 percent/°C in the 400-700-nm region. the absolute spectral responsivity s(}..) using the spec­ For V(}..) filters, colored glass filters from different tral comparator facility (SCF) (Figure 4). A detector sources were used.
Recommended publications
  • 2.1 Definition of the SI
    CCPR/16-53 Modifications to the Draft of the ninth SI Brochure dated 16 September 2016 recommended by the CCPR to the CCU via the CCPR president Takashi Usuda, Wednesday 14 December 2016. The text in black is a selection of paragraphs from the brochure with the section title for indication. The sentences to be modified appear in red. 2.1 Definition of the SI Like for any value of a quantity, the value of a fundamental constant can be expressed as the product of a number and a unit as Q = {Q} [Q]. The definitions below specify the exact numerical value of each constant when its value is expressed in the corresponding SI unit. By fixing the exact numerical value the unit becomes defined, since the product of the numerical value {Q} and the unit [Q] has to equal the value Q of the constant, which is postulated to be invariant. The seven constants are chosen in such a way that any unit of the SI can be written either through a defining constant itself or through products or ratios of defining constants. The International System of Units, the SI, is the system of units in which the unperturbed ground state hyperfine splitting frequency of the caesium 133 atom Cs is 9 192 631 770 Hz, the speed of light in vacuum c is 299 792 458 m/s, the Planck constant h is 6.626 070 040 ×1034 J s, the elementary charge e is 1.602 176 620 8 ×1019 C, the Boltzmann constant k is 1.380 648 52 ×1023 J/K, 23 -1 the Avogadro constant NA is 6.022 140 857 ×10 mol , 12 the luminous efficacy of monochromatic radiation of frequency 540 ×10 hertz Kcd is 683 lm/W.
    [Show full text]
  • Guide for the Use of the International System of Units (SI)
    Guide for the Use of the International System of Units (SI) m kg s cd SI mol K A NIST Special Publication 811 2008 Edition Ambler Thompson and Barry N. Taylor NIST Special Publication 811 2008 Edition Guide for the Use of the International System of Units (SI) Ambler Thompson Technology Services and Barry N. Taylor Physics Laboratory National Institute of Standards and Technology Gaithersburg, MD 20899 (Supersedes NIST Special Publication 811, 1995 Edition, April 1995) March 2008 U.S. Department of Commerce Carlos M. Gutierrez, Secretary National Institute of Standards and Technology James M. Turner, Acting Director National Institute of Standards and Technology Special Publication 811, 2008 Edition (Supersedes NIST Special Publication 811, April 1995 Edition) Natl. Inst. Stand. Technol. Spec. Publ. 811, 2008 Ed., 85 pages (March 2008; 2nd printing November 2008) CODEN: NSPUE3 Note on 2nd printing: This 2nd printing dated November 2008 of NIST SP811 corrects a number of minor typographical errors present in the 1st printing dated March 2008. Guide for the Use of the International System of Units (SI) Preface The International System of Units, universally abbreviated SI (from the French Le Système International d’Unités), is the modern metric system of measurement. Long the dominant measurement system used in science, the SI is becoming the dominant measurement system used in international commerce. The Omnibus Trade and Competitiveness Act of August 1988 [Public Law (PL) 100-418] changed the name of the National Bureau of Standards (NBS) to the National Institute of Standards and Technology (NIST) and gave to NIST the added task of helping U.S.
    [Show full text]
  • 2019 Redefinition of SI Base Units
    2019 redefinition of SI base units A redefinition of SI base units is scheduled to come into force on 20 May 2019.[1][2] The kilogram, ampere, kelvin, and mole will then be defined by setting exact numerical values for the Planck constant (h), the elementary electric charge (e), the Boltzmann constant (k), and the Avogadro constant (NA), respectively. The metre and candela are already defined by physical constants, subject to correction to their present definitions. The new definitions aim to improve the SI without changing the size of any units, thus ensuring continuity with existing measurements.[3][4] In November 2018, the 26th General Conference on Weights and Measures (CGPM) unanimously approved these changes,[5][6] which the International Committee for Weights and Measures (CIPM) had proposed earlier that year.[7]:23 The previous major change of the metric system was in 1960 when the International System of Units (SI) was formally published. The SI is a coherent system structured around seven base units whose definitions are unconstrained by that of any other unit and another twenty-two named units derived from these base units. The metre was redefined in terms of the wavelength of a spectral line of a The SI system after the 2019 redefinition: krypton-86 radiation,[Note 1] making it derivable from universal natural Dependence of base unit definitions onphysical constants with fixed numerical values and on other phenomena, but the kilogram remained defined in terms of a physical prototype, base units. leaving it the only artefact upon which the SI unit definitions depend. The metric system was originally conceived as a system of measurement that was derivable from unchanging phenomena,[8] but practical limitations necessitated the use of artefacts (the prototype metre and prototype kilogram) when the metric system was first introduced in France in 1799.
    [Show full text]
  • Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications
    Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings, wall and ceiling mounting • Tamper-resistant construction options, and plain and FIRE-printed devices, SpectrAlert Advance • Automatic selection of 12- or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela Like the entire SpectrAlert Advance product line, wall-mount horns, • Field-selectable candela settings on wall units: 15, 15/75, strobes, and horn strobes include a variety of features that increase 30, 75, 95, 110, 115, 135, 150, 177, and 185 their application versatility while simplifying installation. All devices • Horn rated at 88+ dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage, SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring, so installers can test wiring continuity before the device is installed. • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections.
    [Show full text]
  • The International System of Units (SI)
    NAT'L INST. OF STAND & TECH NIST National Institute of Standards and Technology Technology Administration, U.S. Department of Commerce NIST Special Publication 330 2001 Edition The International System of Units (SI) 4. Barry N. Taylor, Editor r A o o L57 330 2oOI rhe National Institute of Standards and Technology was established in 1988 by Congress to "assist industry in the development of technology . needed to improve product quality, to modernize manufacturing processes, to ensure product reliability . and to facilitate rapid commercialization ... of products based on new scientific discoveries." NIST, originally founded as the National Bureau of Standards in 1901, works to strengthen U.S. industry's competitiveness; advance science and engineering; and improve public health, safety, and the environment. One of the agency's basic functions is to develop, maintain, and retain custody of the national standards of measurement, and provide the means and methods for comparing standards used in science, engineering, manufacturing, commerce, industry, and education with the standards adopted or recognized by the Federal Government. As an agency of the U.S. Commerce Department's Technology Administration, NIST conducts basic and applied research in the physical sciences and engineering, and develops measurement techniques, test methods, standards, and related services. The Institute does generic and precompetitive work on new and advanced technologies. NIST's research facilities are located at Gaithersburg, MD 20899, and at Boulder, CO 80303.
    [Show full text]
  • Measuring Luminance with a Digital Camera
    ® Advanced Test Equipment Rentals Established 1981 www.atecorp.com 800-404-ATEC (2832) Measuring Luminance with a Digital Camera Peter D. Hiscocks, P.Eng Syscomp Electronic Design Limited [email protected] www.syscompdesign.com September 16, 2011 Contents 1 Introduction 2 2 Luminance Standard 3 3 Camera Calibration 6 4 Example Measurement: LED Array 9 5 Appendices 11 3.1 LightMeasurementSymbolsandUnits. 11 3.2 TypicalValuesofLuminance.................................... 11 3.3 AccuracyofPhotometricMeasurements . 11 3.4 PerceptionofBrightnessbytheHumanVisionSystem . 12 3.5 ComparingIlluminanceMeters. 13 3.6 FrostedIncandescentLampCalibration . 14 3.7 LuminanceCalibrationusingMoon,SunorDaylight . 17 3.8 ISOSpeedRating.......................................... 17 3.9 WorkFlowSummary ........................................ 18 3.10 ProcessingScripts.......................................... 18 3.11 UsingImageJToDeterminePixelValue . 18 3.12 UsingImageJToGenerateaLuminance-EncodedImage . 19 3.13 EXIFData.............................................. 19 References 22 1 Introduction There is growing awareness of the problem of light pollution, and with that an increasing need to be able to measure the levels and distribution of light. This paper shows how such measurements may be made with a digital camera. Light measurements are generally of two types: illuminance and lumi- nance. Illuminance is a measure of the light falling on a surface, measured in lux. Illuminanceis widely used by lighting designers to specify light levels. In the assessment of light pollution, horizontal and vertical measurements of illuminance are used to assess light trespass and over lighting. Luminance is the measure of light radiating from a source, measured in candela per square meter. Luminance is perceived by the human viewer as the brightness of a light source. In the assessment of light pollution, (a) Lux meter luminance can be used to assess glare, up-light and spill-light1.
    [Show full text]
  • Radiometry and Photometry
    Radiometry and Photometry Wei-Chih Wang Department of Power Mechanical Engineering National TsingHua University W. Wang Materials Covered • Radiometry - Radiant Flux - Radiant Intensity - Irradiance - Radiance • Photometry - luminous Flux - luminous Intensity - Illuminance - luminance Conversion from radiometric and photometric W. Wang Radiometry Radiometry is the detection and measurement of light waves in the optical portion of the electromagnetic spectrum which is further divided into ultraviolet, visible, and infrared light. Example of a typical radiometer 3 W. Wang Photometry All light measurement is considered radiometry with photometry being a special subset of radiometry weighted for a typical human eye response. Example of a typical photometer 4 W. Wang Human Eyes Figure shows a schematic illustration of the human eye (Encyclopedia Britannica, 1994). The inside of the eyeball is clad by the retina, which is the light-sensitive part of the eye. The illustration also shows the fovea, a cone-rich central region of the retina which affords the high acuteness of central vision. Figure also shows the cell structure of the retina including the light-sensitive rod cells and cone cells. Also shown are the ganglion cells and nerve fibers that transmit the visual information to the brain. Rod cells are more abundant and more light sensitive than cone cells. Rods are 5 sensitive over the entire visible spectrum. W. Wang There are three types of cone cells, namely cone cells sensitive in the red, green, and blue spectral range. The approximate spectral sensitivity functions of the rods and three types or cones are shown in the figure above 6 W. Wang Eye sensitivity function The conversion between radiometric and photometric units is provided by the luminous efficiency function or eye sensitivity function, V(λ).
    [Show full text]
  • Candelas, Lumens and Lux by Owen Ransen
    Candelas, Lumens and Lux By Owen Ransen A light introduction to illumination terms, ideas, and mathematics. Samples of the first two pages of each chapter. Table of Contents How to use this book.................................................................................5 1. Candelas, Lumens and Lux...................................................................6 2. Luminance.............................................................................................34 3. Photometries.........................................................................................50 4. Internal Lighting...................................................................................64 5. Glare.......................................................................................................84 6. Roadway Lighting...............................................................................112 7. Light sources and efficiency.............................................................134 How to use this book This book is for people who are starting to learn about lighting engineering or who need to know the basics of the subject. I've made it as simple, using graphical explanations of mathematical and physical ideas. There is mathematics in this book, but nothing beyond high school level, a few formulas, a tiny bit of trigonometry, nothing you need to be scared of! As we've seen in the financial crisis of 2008/2009, mathematics without a concrete idea of what it is happening in the real world can lead to disaster. So this book has
    [Show full text]
  • The International System of Units (SI) - Conversion Factors For
    NIST Special Publication 1038 The International System of Units (SI) – Conversion Factors for General Use Kenneth Butcher Linda Crown Elizabeth J. Gentry Weights and Measures Division Technology Services NIST Special Publication 1038 The International System of Units (SI) - Conversion Factors for General Use Editors: Kenneth S. Butcher Linda D. Crown Elizabeth J. Gentry Weights and Measures Division Carol Hockert, Chief Weights and Measures Division Technology Services National Institute of Standards and Technology May 2006 U.S. Department of Commerce Carlo M. Gutierrez, Secretary Technology Administration Robert Cresanti, Under Secretary of Commerce for Technology National Institute of Standards and Technology William Jeffrey, Director Certain commercial entities, equipment, or materials may be identified in this document in order to describe an experimental procedure or concept adequately. Such identification is not intended to imply recommendation or endorsement by the National Institute of Standards and Technology, nor is it intended to imply that the entities, materials, or equipment are necessarily the best available for the purpose. National Institute of Standards and Technology Special Publications 1038 Natl. Inst. Stand. Technol. Spec. Pub. 1038, 24 pages (May 2006) Available through NIST Weights and Measures Division STOP 2600 Gaithersburg, MD 20899-2600 Phone: (301) 975-4004 — Fax: (301) 926-0647 Internet: www.nist.gov/owm or www.nist.gov/metric TABLE OF CONTENTS FOREWORD.................................................................................................................................................................v
    [Show full text]
  • How to Measure and Characterize LED Lighting Fixtures
    How to Measure and Characterize LED Lighting Fixtures. Explanation of Photometric Quantities and Measurement Instruments Requirements According to CIE Standards and Other International Norms by Mikolaj Przybyla, Brand Director About GL Optic : GL Optic is the brand name of JUST Normlicht GmbH Germany the world's leading supplier of the standardized light solutions for printing and graphic arts industries. For more than 30 years Just has been developing the innovative solutions which are of the highest quality in standard-light viewing conditions. About GL Optic : The spectral light measurement project was created at the end of 2009 by Michael Gall the owner and CEO of Just Normlicht in cooperation with Jan Lalek, a Polish physicist who had been involved in the creation of the innovative LED tunable standard lighting systems. They also developed together the light quality assurance instruments installed at Just spectral measurements laboratory. How to measure LEDs When designing an LED lighting fixtures, we instantly had to deal with parameters and issues such as Flux and Colour shift with temperature and current, accurate current control and heat management are just a few of them. Therefore the accurate light measurement system is crucial for the development of these LED products. This presentation will cover basic information on light measurement procedures, international standards as well as the presentation of available instrumentation for very different measurement tasks from luminous flux measurement with integrating spheres to luminance
    [Show full text]
  • EL Light Output Definition.Pdf
    GWENT GROUP ADVANCED MATERIAL SYSTEMS Luminance The candela per square metre (cd/m²) is the SI unit of luminance; nit is a non-SI name also used for this unit. It is often used to quote the brightness of computer displays, which typically have luminance’s of 50 to 300 nits (the sRGB spec for monitor’s targets 80 nits). Modern flat-panel (LCD and plasma) displays often exceed 300 cd/m² or 300 nits. The term is believed to come from the Latin "nitere" = to shine. Candela per square metre 1 Kilocandela per square metre 10-3 Candela per square centimetre 10-4 Candela per square foot 0,09 Foot-lambert 0,29 Lambert 3,14×10-4 Nit 1 Stilb 10-4 Luminance is a photometric measure of the density of luminous intensity in a given direction. It describes the amount of light that passes through or is emitted from a particular area, and falls within a given solid angle. The SI unit for luminance is candela per square metre (cd/m2). The CGS unit of luminance is the stilb, which is equal to one candela per square centimetre or 10 kcd/m2 Illuminance The lux (symbol: lx) is the SI unit of illuminance and luminous emittance. It is used in photometry as a measure of the intensity of light, with wavelengths weighted according to the luminosity function, a standardized model of human brightness perception. In English, "lux" is used in both singular and plural. Microlux 1000000 Millilux 1000 Lux 1 Kilolux 10-3 Lumen per square metre 1 Lumen per square centimetre 10-4 Foot-candle 0,09 Phot 10-4 Nox 1000 In photometry, illuminance is the total luminous flux incident on a surface, per unit area.
    [Show full text]
  • Towards a New Realization of the SI-Base Unit “Candela“
    Lux junior 2015 25. bis 27.9.15 Dörnfeld Towards a new realization of the SI-base unit “Candela“ Schneider, P., Sperling, A., Salffner, K., Nevas, S. Fachbereich 4.1 Photometrie und angewandte Radiometrie Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany [email protected] 1 Introduction The SI-base unit “Candela” for luminous intensity at Physikalisch-Technische Bundesanstalt (PTB) is achieved through a traceability chain to the radiometric national standard of PTB following the definition of the “Candela” in 1979 [1]. The unit is realised with a network of photometers and luminous intensity standard lamps [2]. By means of the planned new realization the traceability route will become shorter and a lower uncertainty in the realization of luminous intensity and the derived photometric units will become possible. 2 Realisation and maintenance of the unit: State of the art For the realization of the unit “Candela”, calibrated detectors and light sources are used. In the first step of the traceability chain for calibration of photometers the radiant power of a monochromatic source (laser) is compared to the electrical power necessary to substitute this optical power within a cryogenic radiometer. This substitution is used to determine the spectral power responsivities of Si-trap detectors at a set of discrete wavelengths compared to the cryogenic radiometer [3]. By using a macroscopic model for the spectral responsivity function of the Si-trap detectors, the measured discrete responsivity values resulting from the comparison with the cryogenic radiometer are interpolated over the full spectral range of interest. The spectral power responsivities of these trap detectors are then transferred to other trap detectors, photodiodes and filtered radiometers and converted into spectral irradiance responsivities.
    [Show full text]