TRUE HEPA AIR PURIFIER Fan for HPA020 Model Series Humidifier
Total Page:16
File Type:pdf, Size:1020Kb
Air Purifier Heater TRUE HEPA AIR PURIFIER Fan For HPA020 Model Series Humidifier Filter 9. DO NOT use air purifier where combustible gases IMPORTANT SAFETY or vapors are present. 10. DO NOT expose the air purifier to rain, or use near INSTRUCTIONS water in a bathroom, laundry area or other damp location. READ AND SAVE THESE 11. The air purifier must be used in its horizontal position only. SAFETY INSTRUCTIONS 12. DO NOT allow foreign objects to enter ventilation BEFORE USING THIS or exhaust opening as this may cause electric shock or damage to the air purifier. DO NOT block AIR PURIFIER air outlets or intakes. 13. Locate air purifier near the outlet and avoid using When using electrical appliances, basic an extension cord or power-strip. precautions should always be followed to 14. This appliance has a polarized plug (one blade reduce the risk of fire, electric shock, and is wider than the other). To reduce the risk of injury to persons, including the following: shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in 1. Read all instructions before operating the air the outlet, reverse the plug. If it still does not fit, purifier. contact a qualified electrician. 2. Place air purifier where it is not easily knocked DO NOT attempt to defeat this safety feature. over by persons in the household. 15. A loose fit between the AC outlet (receptacle) and 3. Always turn the air purifier controls to the plug may cause overheating and a distortion of OFF position and unplug from the wall outlet the plug. Contact a qualified electrician to replace when not in use. loose or worn outlet. 4. To disconnect the air purifier, first turn the control 16. DO NOT sit, stand or place heavy objects on the to the OFF position, grip the plug and pull it from air purifier. the wall outlet when not in use. 17. Disconnect power supply before servicing. NEVER pull by the cord. 5. DO NOT use any product with a damaged cord 18. SAVE THESE INSTRUCTIONS or plug or if product malfunctions, is dropped or damaged in any manner. Keep the cord away from For FCC compliance information, please see heated surfaces. last page of this manual. 6. DO NOT use air purifier outdoors. WARNING: To Reduce The Risk of Fire or 7. DO NOT use air purifier unless it is fully assembled. Electric Shock, Do Not Use This Air Purifier 8. DO NOT run power cord under carpets, and With Any Solid-State Speed Control Device. DO NOT cover with throw rugs. Arrange cord such that it will not be tripped over. YOUR AIR PURIFIER Top of air purifier Bottom of air purifier Clean Air is Released Back into the Room DO NOT IMMERSE IN WATER! This side in Replace every 12 months G ¡NO LO SUMERJA EN AGUA! Substituya cada 12 meses Este lado adentro P/N A001610R0 www.replacementfilters.com • 1-800-477-0457 Control Panel True HEPA Filter & Odor Reducing Pre-Filter A A Air Intake R R True HEPA Filter Odor Reducing Pre-Filter A A R R HOW YOUR AIR PURIFIER WORKS This model air purifier incorporates a 2-stage cleaning system to help clean the air that passes through the 2 filter in the unit (Fig. 1). STAGE 1 STAGE 2 Odor Reducing Filter Activated Carbon Pre-filter traps larger Stage 1: Pre-filter particles and household odors* Stage 2: HEPA Filter captures up to 99.97% of microscopic particles, as small as .3 microns* *From the air that passes through the filter Fig. 1 SET-UP • Select a firm, level and flat location on the floor at least 6 inches away from wall or furniture. • When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminants. This may also help prolong the life of the filter. If the unit is placed on a light colored carpet, a small mat or rug should be used underneath to prevent staining. This is especially important in homes with contamination from smoking, fireplaces, or where candles are burned. • Ensure the front of the unit faces away from the closest wall or furniture. • Ensure no grilles are blocked. 2 INSTALLING THE TRUE HEPA FILTER AND ODOR REDUCING PRE-FILTER The True HEPA Filter and Odor Reducing Pre-filter are supplied with Fig. 2 your air purifier. They are wrapped to ensure purity and are labeled to help identify the proper replacement filter (Type True HEPA Filter and Type A Odor AReducing Pre-filter). • Turn off and unplug the air purifier. • Turn the air purifier upside down on a flat surface. The filter is visible from theR bottomR of the unit (Fig. 2). • Remove the True HEPA filter by grasping the filter from the finger notches. There are small molded tabs that secure the filter in place and prevent it from slipping out of the unit. Pull away from tabs and up to remove. When removing a used filter that is not wrapped in Molded tabs plastic, pull the red tab to remove. secure filter • Remove the protective plastic wrap from the HEPA filter and pre- filter. • Install the pre-filter first by sliding it in behind the front grille of the air purifier and securing it in the molded slots. • Install the True HEPA filter by sliding it in the opening on bottom of the air purifier. Ensure that the red tab is accessible for easy removal. OPERATION • Ensure the air purifier is plugged into a working Check Filter electrical outlet Power ON LED Indicator Light • Turn the Power Knob to desired setting FILTER RESET (O = Off, III = High, II = Medium, I = Low) Cleaning Button Levels Portable air purifiers are more effective in rooms where all the doors and windows are closed. It is Power recommended that you run your air purifier while Control Knob Fig. 3 you are at home to help clean the air. ENERGY STAR® This product earned the ENERGY STAR® by meeting strict energy efficiency guidelines set by the U.S. EPA. The U.S. EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product. The energy efficiency of this ENERGY STAR® qualified model is measured based on a ratio between the model’s CADR for Dust and the electrical energy it consumes, or CADR/Watt. 3 ELECTRONIC FILTER CHECK REMINDER This model has an electronic filter check to remind you when to check Fig. 4 and replace your filters based on the air purifier’s hours of use. A red LED will illuminate when it is time to check/replace your filters. Check When the HEPA filter or pre-filter needs to be replaced, the light will Filter Indicator remain on until it is RESET. You may unplug the air purifier without Light interrupting the filter check. You should periodically check the filters depending on operating conditions, the TRUE HEPA filter should be replaced every 12 months and the pre-filter every 3 months. REPLACE WITH TRUE HEPA FILTER and ODOR REDUCING PRE-FILTER A A To RESET the Electronic Filter Check: When the filter check light remains on and solid, it is time to replace the Odor ReducingR Pre-filterR and reset the filter monitor. With the unit powered ON, press the FILTER RESET button next to the Check Filter LED and hold for approximately 2 seconds until the light turns off (Fig. 4). When the LED illuminates and is flashing, it is time to replace the True HEPA filter and reset the filter monitor. With the unit powered ON, press FILTER RESET button and hold for approximately 2 seconds until the light turns OFF (Fig. 4). Manual (or Early) Reset of Electronic Filter Check Depending on your individual usage (environment and hours used), you may need to replace the filters more or less frequently. Each time you replace your filters, you should reset the filter monitor. You may manually reset the filter monitor for the pre-filter or the HEPA filter, or both. If you change the pre-filter or True HEPA filter before the Check Filter LED is illuminated, it is possible to reset the filter monitor. You must first manually illuminate the Check Filter LED. Follow these steps: 1. With unit powered ON, press the FILTER RESET button for 5 seconds to illuminate the LED in “solid” mode. 2. To reset filter monitor for pre-filter: press and hold FILTER RESET button for 2 seconds until LED changes to flashing mode. 3. TAP FILTER RESET button to shut LED off. The pre-filter monitor is now set to “clean status”. 4. To reset filter monitor for HEPA filter: LED must be in “flashing mode”. Follow Step 1 above, then TAP FILTER RESET button again to illuminate the LED in “flashing mode”. 5. Press and hold FILTER RESET button for 2 seconds until LED shuts off. The HEPA filter monitor is now set to “clean status”. 6. To reset filter monitor for both pre-filter and HEPA filter: Follow Steps 1,2, and 5 above. CLEANING AND STORAGE We recommend that you clean the air purifier at least once every 3 months and before extended storage. Use only a dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER, WAX POLISH, OR ANY CHEMICAL SOLUTION. If your Air Purifier will not be used for more than 30 days, we recommend that you: • Remove the True HEPA filter and the Odor Reducing Pre-filter from the unit.