What Are Inbuilding Solutions

Total Page:16

File Type:pdf, Size:1020Kb

What Are Inbuilding Solutions DEGREE PROJECT, IN COMMUNICATION SYSTEMS , SECOND LEVEL STOCKHOLM, SWEDEN 2015 A Study of Multiband Indoor Radio Distribution System BIKASH SHAKYA KTH ROYAL INSTITUTE OF TECHNOLOGY SCHOOL OF INFORMATION AND COMMUNICATION TECHNOLOGY 2 A STUDY OF MULTIBAND INDOOR RADIO DISTRIBUTION SYSTEM BIKASH SHAKYA Master of Science Thesis performed at the Radio Communication Systems Group, KTH October 2014 Internal Advisor: Mats Nilsson External Advisor: Tord Sjölund Examiner: Associate Prof. Anders Västberg 3 Abstract: The mobile indoor traffic are increasing exponentially which is the current challenge in indoor coverage and design for most of the researchers and business companies to develop further. There are different trade-off to provide different indoor services with the use of different repeater system, distributed antenna network (active and passive), macro cells indoor penetrations and many more. As the use of energy effective materials for construction of buildings have made a blockage of RF signals from macro cells, usually a separate installations are done to provide indoor coverage for different services such as TRTRA, GSM, UNTS, LTE and WLAN in indoor environments for large campuses, industrial complex, sports arena, tunnels and office buildings. This separate installations increases the cost, installation space and time which can be solved using the same infrastructure to provide multiple of mobile indoor solutions using smart integrated solutions where many mobile services can be distributed indoor using the same distributed antenna network using active and passive networks. This thesis investigates the advantage and disadvantage of different types of active and passive distributed antenna system with the integrated antenna network to compare the coverage and cost analysis. The coverage analysis was done to compare the RSSI level by adding different frequency bands into the indoor network for both active and passive DAS design. Different types of sample design model was used to verify the coverage analysis. It can be seen from the coverage analysis that an integrated system with all in one solution also has a better coverage compared to typical active and passive design which can be used in future in building design as One Net Solution. Also the cost analysis was done for both CAPEX and OPEX to find the cost estimation for different indoor models. It showed that the integrated solution is the most expensive solution but if it has a case of large design venues, then integrate active solution can be the only solutions. Passive design cannot cover large scale areas. It is suitable only for small and medium sized venues. 4 Acknowledgement: I would like to thank my two supervisor Tord Sjölund (MIC Nordic) and Mats Nilsson (Wireless@kth) for their continuous support, great motivation, valuable advice and parental guidance throughout my thesis work from start till the end. Without their support and input, I would have never finished this thesis. I would like to extent my thanks to my examiner Anders Västberg for providing me an adequate amount of time to finish this thesis and his comments. I would also like to thank Johan Jober (Rewicom) for his idea to start this thesis and help me understand the topic. Also I cannot forget to thank my department and my program coordinator May-Britt Eklund Larsson for the support throughout my study period. Also I would like to thank the entire team of MIC Nordic (Specially Mats, Henrik, Carina, Petter, Håkan, Janne) for their continuous motivation and feedback to finish this thesis. They created a friendly and good working environment to get motivated and also many resources that I needed to finish the thesis. I would also like to give special thanks to my parents who are always with me in any case and supported me in every possible way to finish this thesis. Last but not the least, I would like to thank everyone who was involved in this thesis directly or indirectly. Thank you for making this study completed. 5 Contents ACRONYMS AND ABBREVIATION ............................................................................................... 10 CHAPTER 1 INTRODUCTION ..................................................................................................... 11 1.1 INTRODUCTION .................................................................................................................... 11 1.2 PREVIOUS WORK AND THESIS MOTIVATION ........................................................................ 12 1.3 RESEARCH PROBLEM DEFINITION ....................................................................................... 13 CHAPTER 2 TECHNOLOGY BACKGROUND.......................................................................... 15 2.1 SYSTEM TECHNOLOGY ........................................................................................................ 15 2.1.1 GSM 900/1800 MHz .......................................................................................... 15 2.1.2 UMTS 2100 MHz ............................................................................................... 15 2.1.3 WLAN 2.4 GHz................................................................................................... 16 2.1.4 TETRA 400 MHz ................................................................................................ 17 2.1.5 GPS .................................................................................................................... 18 2.1.6 LTE (Long Term Evolution) ............................................................................... 19 2.2 MIMO (MULTIPLE INPUT MULTIPLE OUTPUT) .................................................................... 22 2.3 INDOOR SYSTEMS ................................................................................................................ 23 2.3.1 Traditional Indoor Solutions .............................................................................. 24 2.3.2 Integrated Indoor Solutions ............................................................................... 25 2.3.3 Leaky Cables ...................................................................................................... 25 2.3.3.1 Technical Data of the Radiating Cables........................................................ 26 2.4 DISTRIBUTED ANTENNA SYSTEM (DAS) ............................................................................. 27 2.4.1 Passive DAS: ..................................................................................................... 27 2.4.2 Active DAS: ....................................................................................................... 27 CHAPTER 3 THEORY ................................................................................................................... 28 3.1 LINK BUDGET CALCULATION .............................................................................................. 28 3.2 PROPAGATION MODEL......................................................................................................... 29 3.2.1 Free Space Path Loss ......................................................................................... 29 3.2.2 Keenan-Motley Model ........................................................................................ 30 3.2.3 Path Loss Slope Model ....................................................................................... 30 CHAPTER 4 METHODOLOGY AND SYSTEM DESIGN STRATEGY .................................. 31 4.1 SYSTEM DESIGN .................................................................................................................. 31 4.1.1 Active System Diagram for 2G, 3G, RAKEL ...................................................... 32 4.1.2 Active System Diagram for 2G, 3G, RAKEL and 4G MIMO ............................. 32 4.1.3 Active System Diagram for 2G, 3G, RAKEL and 4G SISO ................................ 32 4.1.4 Passive System Diagram for 2G, 3G, RAKEL ................................................... 33 4.1.5 Passive System Diagram for 2G, 3G, RAKEL and 4G MIMO ........................... 33 4.1.6 Passive System Diagram for 2G, 3G, RAKEL, 4G SISO ................................... 33 4.1.7 Integrated Solution System Diagram ................................................................. 33 6 4.2 MEASUREMENT TOOLS ........................................................................................................ 34 4.3 MEASUREMENT LOCATIONS ................................................................................................ 35 4.4 MEASUREMENT METHODOLOGY ......................................................................................... 36 CHAPTER 5 COVERAGE ANALYSIS ........................................................................................ 38 5.1 ACTIVE DISTRIBUTED ANTENNA SYSTEM ........................................................................... 38 5.1.1 RAKEL, 2G, 3G.................................................................................................. 39 5.1.2 RAKEL, 2G, 3G, 4G MIMO ............................................................................... 39 5.1.3 RAKEL, 2G, 3G, 4G SISO .................................................................................. 40 5.2 PASSIVE DISTRIBUTED ANTENNA SYSTEM .......................................................................... 40 5.2.1 RAKEL, 2G, 3G.................................................................................................. 41 5.2.2 RAKEL, 2G, 3G, 4G MIMO ..............................................................................
Recommended publications
  • Introducing a Digital Distributed Antenna System (DAS) for Public Safety In-Building Communications
    Introducing A Digital Distributed Antenna System (DAS) For Public Safety In-Building Communications THE NEXT GENERATION DIGITAL PUBLIC SAFETY SOLUTION Dali Wireless | Whitepaper | March 2016 DALI WIRELESS © MARCH 2016 | Whitepaper www.daliwireless.com Introduction Reliable public safety in-building radio communications are vital in today’s emergency services operation, from dispatch to mission critical situations, and from voice only capabilities to voice and data. Public safety communications have evolved from fire call boxes, analog mobile radios to digital mobile radios and trunked radio systems. This evolution was mainly driven by technological advancements and the need for higher reliability. Traditionally, public safety uses lower frequency bands such as 150 MHz and 450 MHz. As the public safety network operations move to higher spectrum bands such as 700MHz or 800 MHz, the propagation characteristics of spectrum limits the in-building signal penetration. In addition, with more complex building environments such as dense building materials like aluminum or steel, energy efficient windows and green buildings meeting LEED standards, signals can be even further reduced or blocked which can impair effective communications between the first responders. Improving public safety coverage indoors is a long-standing challenge. An evolution in the in-building public safety infrastructure (Figure 1) is required to allow two-way radios or trunked radio systems to work seamlessly and reliably inside buildings and in underground tunnels, metros or mines and remote or isolated areas. Digital RF distribution Distributed system for in- Antenna building and System individual state (DAS) for in- requirements Off-air building Repeaters for Coverage in-building coverage Voting Receivers Driven by the need to support both current and future requirements Figure 1.
    [Show full text]
  • Cyber Security Risk Management for Connected Railroads
    U.S. Department of Transportation Office of Research, Federal Railroad Development and Technology Administration Washington , DC 20590 Cyber Security Risk Management for Connected Railroads No aProximate Field Logic Proximatea Access Access Needed Controllers Required _____..._ _________ __, Railroad Radio CPS Local or Carrier Network Communications Base Stations Field Linka es Closed Network Short Range RF Balises Accidentally Cleared Signal (tt.g. C&S Testing or Malicious lnJeCtion) . : 8m Block RelayMtal PLC Vital Radio Code ___J~ IT'll_!_l'~ R92~m~ Extralayerof Line Command '\Y' ; 1~ne 1ze/Ac\rvafif protection I , . Lack of acknowledgement False acknoY,,;edgement (~~the-middle) (dispatcher not able to know the 8Ctual status C&S Testing Signal ol blue block relay) MOWlimil Clearing ' '...====='....""'.""."' False Injection ___ Spoofing _____: 110.--•-I I (Attack) I ____________________ J +Work l im it Misunderstood = Risk DOT/FRA/ORD-20/25 Final Report | June 2020 NOTICE This document is disseminated under the sponsorship of the Department of Transportation in the interest of information exchange. The United States Government assumes no liability for its contents or use thereof. Any opinions, findings and conclusions, or recommendations expressed in this material do not necessarily reflect the views or policies of the United States Government, nor does mention of trade names, commercial products, or organizations imply endorsement by the United States Government. The United States Government assumes no liability for the content or use of the material contained in this document. NOTICE The United States Government does not endorse products or manufacturers. Trade or manufacturers' names appear herein solely because they are considered essential to the objective of this report.
    [Show full text]
  • Transcom Instruments Products Catalog 2017
    We Focusing c Data without tolerance limits is not binding. Subject change. to limits is not binding. without tolerance Data 2017 August, in China, 2017. Published I nstrument, Transcom TRANSCOM INSTRUMENTS Cellular Network/Critical PRODUCTS CATALOG 2017 Communication 2nd edition RF Component Manufacturing Research/Education Spectrum Monitoring Add:6F,Buliding29,No.69 Guiqing Road,Xuhui District,Shanghai,PRC.200233 Tel:+86 21 6432 6888 Fax:+86 21 6432 6777 Mail:[email protected] www.transcomwireless.com We Focusing c Data without tolerance limits is not binding. Subject change. to limits is not binding. without tolerance Data 2017 August, in China, 2017. Published I nstrument, Transcom TRANSCOM INSTRUMENTS Cellular Network/Critical PRODUCTS CATALOG 2017 Communication 2nd edition RF Component Manufacturing Research/Education Spectrum Monitoring Add:6F,Buliding29,No.69 Guiqing Road,Xuhui District,Shanghai,PRC.200233 Tel:+86 21 6432 6888 Fax:+86 21 6432 6777 Mail:[email protected] www.transcomwireless.com We Focusing TRANSCOM INSTRUMENTS PRODUCTS CATALOG 2017 Chapter Model Name Cellular Network Measurement SpecMini Handheld Spectrum Analyzer 5 SiteHawk Handheld Cable & Antenna Analyzer 13 TSP Transmitter TSP Pilot Transmitter 21 c Data without tolerance limits is not binding. Subject change. to limits is not binding. without tolerance Data 2017 August, in China, 2017. Published I nstrument, Transcom TRANSCOMTSP Scanner INSTRUMENTSTSP Scanner 2 IoT Scanner NB-IoT/eMTC Scanner 36 Manufacturing & Education Micro-Tx Vector Signal
    [Show full text]
  • Communications Based Train Control (CBTC)
    GOVERNMENT OF INDIA MINISTRY OF RAILWAYS An Introductory Handbook on Communications Based Train Control (CBTC) End Users: Indian Railways Signal Engineers CAMTECH/S/PROJ/2020-21/SP9/1.0 April 2021 INDIAN RAILWAYS Centre for Advanced Maintenance Technology Maharajpur, Gwalior (M.P.) Pin Code – 474 005 i This page has been left blank intentionally ii Introductory Handbook on Communications Based Train Control (CBTC) CAMTECH/S/PROJ/2020-21/SP9/1.0 April 2021 iii This page has been left blank intentionally iv Foreword Conventional railway signalling is based on colour light signals and train detection with the help of track circuits and axle counters. Although this technology is suitable for detection and control of trains it is still not able to utilize the section capacity to its full advantage. Over the last decade, railways have seen a huge transition from conventional railway signalling systems to modern signalling systems. As there are continuous improvements in technology, we need to keep pace with the latest trends and keep ourselves updated. Communications-Based Train Control (CBTC) is a modern communication- based system that uses radio communication to transfer timely and accurate train control information. CBTC is the choice of mass-transit railway operators today, with over a hundred systems currently installed worldwide. In India also, the CBTC technology is finding applications in Metro railways. As CBTC is an upcoming technology, CAMTECH has issued this introductory handbook for Signal & Telecommunication engineers to get them acquainted with this and help them in implementing the system in the context of working on Indian Railways. I hope that this handbook will prove useful to S&T engineers of Indian Railways in enhancing their knowledge.
    [Show full text]
  • Underground Mine Communications Infrastructure Guidelines Part Iii: General Guidelines
    20180921_Underground Mine Communications Infrastructure III-GMG-UM-v01-r01 UNDERGROUND MINE COMMUNICATIONS INFRASTRUCTURE GUIDELINES PART III: GENERAL GUIDELINES SUBMITTED BY Underground Communications Infrastructure Sub-Committee of the Underground Mining Working Group VERSION DATE 21 Sept 2018 APPROVED BY Vote of the Underground Mining Working Group 25 Feb 2019 and GMG Governing Council 11 Mar 2019 EDITED BY Purple Rock Inc. 26 Nov 2018 PUBLISHED 13 Mar 2019 DATE DOCUMENT TO BE REVIEWED 13 Mar 2024 PREPARED BY THE UNDERGROUND MINING WORKING GROUP UNDERGROUND COMMUNICATIONS INFRASTRUCTURE SUB-COMMITTEE Global Mining Guidelines Group (GMG) i | UNDERGROUND MINE COMMUNICATIONS INFRASTRUCTURE GUIDELINES – PART III: GENERAL GUIDELINES ORGANIZATIONS INVOLVED IN THE PREPARATION OF THESE GUIDELINES ABB, Accenture, Agnico Eagle Mines LTD, Alexander Proudfoot Africa, Alternate Futures PTY Ltd, Ambra Solutions, Anglo American Ltd, Aveva Group PLC, Barrick Gold, BBA, Bestech, BHP, Caterpillar, CBS Australia, CEMI, Cisco, CommitWorks, CSIR, Dassault Systemes GEOVIA, Datamine, De Beers Group Services, Deloitte, DesSoft, Deswik, DetNet, Dexcent, Dwyka Mining Services, E.C. MacDonald Inc., Echo Engineering Ltd, Epiroc, Excel Project Management, Glencore, Global IO, Gription, Hatch, Hexagon Mining, iMining, Inisys Africa BIM Solutions, Innovative Wireless Technologies, Ivy Tech Trading, JG & Co Manage- ment Consulting, JV Associates, KNS Communications, Komatsu, KPMG, Laird, Leoka Engineering, Maclean Engineering (Africa), Maestro Digital Mine, MetsTech,
    [Show full text]
  • Tutorial on Wireless Communications and Electronic Tacking
    This page intentionally left blank PREFACE This document is being provided to the mining industry as a working draft. The intent is to make information available to labor, industry, regulators, and academia that is relevant to the Communications and Tracking systems that are being installed for compliance with the MINER Act. As a working draft, the document has not yet been through the rigorous external peer review process that NIOSH publications require before being distributed as an official NIOSH document. The document has been reviewed internally; however, it was determined that NIOSH review and release process would not likely be completed for the June 15, 2009 compliance date that is required by the MINER Act. Therefore, the decision was made to distribute this document as a working draft and to follow with a final publication as quickly as possible. We would like to acknowledge the contributions of the Defense Information Systems Agency, Joint Spectrum Center, Annapolis, MD which prepared much of the material contained in this document under an Inter-Agency Agreement (IAA) with NIOSH. We also want to acknowledge the contributions of the NIOSH research staff, whose extraordinary effort made this document possible in an exceptionally short period of time. Tutorial on Wireless Communications & Electronic Tracking TABLE OF CONTENTS 1. INTRODUCTION ...................................................................................................4 2. CT TECHNOLOGY OVERVIEW............................................................................6
    [Show full text]
  • CANMET Mining and Mineral Sciences Laboratories
    CANMET Mining and Mineral Sciences Laboratories Summary Study of Underground Communications Technologies Final Project Report by Pierre Laliberté, Eng. Experimental-mine Project: 603478-00-0 Report CANMET-MMSL 09-004(TR) Version: May 2009 CONFIDENTIEL DÉCLASSIFIÉ : Natural Resources Canada makes no representation or warranty respecting the results arising from the work, either expressly or implied by law or otherwise, including but not limited to implied warranties or conditions of merchantability or fitness for a particular purpose. © Crown Copyrights Reserved. Her Majesty the Queen in Right of Canada as represented by Natural Resources Canada, 2009. Underground Communications Technologies Version: May 6, 2009 DISCLAIMER Any determination and/or reference made in this report with respect to any specific commercial product, process or service by trade name, trademark, manufacturer or otherwise shall be considered to be opinion; CANMET-MMSL makes no, and does not intend to make any, representations or implied warranties of merchantability or fitness for a particular purpose nor is it intended to endorse, recommend or favour any specific commercial product, process or service. The views and opinions of authors expressed herein do not necessarily state or reflect those of CANMET-MMSL and may not be used for advertising or product endorsement purposes. © Crown Copyrights Reserved. Her Majesty the Queen in Right of Canada as represented by Natural Resources Canada, 2009. CANMET-MMSL 09-004(TR) page 1 of 113 Underground Communications Technologies
    [Show full text]
  • Tutorial on Wireless Communications and Electronic Tracking Part 2: Advanced 1.0 Introduction
    NIOSH Mining Safety and Health Content Tutorial on Wireless Communications and Electronic Tracking Part 2: Advanced 1.0 Introduction In 2006, three major underground coal mine accidents in the United States claimed the lives of 19 miners and prompted lawmakers to pass the Mine Improvement and New Emergency Response Act (MINER Act) of 2006. One of the requirements of the MINER Act is to provide wireless two-way communications and location information between underground workers and surface personnel following an underground accident. At the time of the accidents in 2006, most coal mine communications systems consisted of either leaky feeder systems or pager phones. A few mines had electronic brass- in/brass-out systems or zone-based tracking, but location tracking throughout the entire mine was not a common practice. Since then, efforts to develop new radio communications and personnel tracking technology have resulted in many new systems on the market for underground mine applications, and new systems continue to be introduced. New communications technologies include radio node network systems, such as mesh and Wi-Fi; improved leaky feeder systems; low-frequency, through-the-earth systems ; medium frequency radios; and combinations of these technologies. New personnel electronic tracking technologies include radio frequency identification (RFID) and radio ranging techniques. Due to the increasing availability of new systems, the Mine Safety and Health Administration (MSHA) requires underground coal mines to have compliant communications and electronic tracking (CT) systems installed by June 15, 2011. The new CT technology that is available may be unfamiliar to mining professionals who need to purchase, install, and use this technology.
    [Show full text]
  • Underground Mine Communications, Control and Monitoring
    Bureau of Mines Information Circular/l984 Underground Mine Communications, Control and Monitoring By Staff, Bureau of Mines UNITED STATES DEPARTMENT OF THE INTERIOR - -- Information Circular 8955 Underground Mine Communications, Control and Monitoring By Staff, Bureau of Mines UNITED STATES DEPARTMENT OF THE INTERIOR James G. Watt, Secretary BUREAU OF MINES Robert C. Horton. Director Library of Congress Cataloging in Publication Data : . Underground mine communications, control and monitoring. (Information circular / United States Department of the Interior, Bu- reau of Mines ; 8955) Includes bibliographical references. Supt. of Docs. no.: I 28.27:8955. 1. Mine communication systems. I. United States. Bureau of Mines. 11. Series: Information circular (United States. Bureau of Mines) ; 8955. TN295,U4 [Till3441 622s [622',2] 83-600288 & PREFACE Since 1969, the Bureau of Mines, U.S. Department of Interior, has sponsored numerous programs aimed at improving methods of underground communication. As a result of these research and development programs, a wealth of information has been made available to the mining industry. Unfortunately, some of this material is highly analytical, and most is written in terms best understood by communication specialists. Because of the volume of data (over 100 studies have been performed) and its highly technical nature, most of the information is not readily avail- able for practical application by mine operators. This manual brings together relevant data from all previous reports, studies, and other sources, and presents these data in such a way that they may be applied by the mining industry to improve communications in underground mines. This report is intended as a guideline and not as a comprehensive documentary of mine equipment.
    [Show full text]
  • Waterloo & City Cellular Network Trial Report
    Programme London Underground Commercial Telecommunications Project Public Cellular Network Feasibility Study Document Reference D-CEL1560 Version 1.8 Title Waterloo & City Cellular Network Trial Report Signature Date Prepared By: Robert Ivers RF Consultant Peer Review By: Anthony Hickey Radio Engineering Lead Approved By: John Lichnerowicz Design Group Lead Reviewed By: James Batchelor London Underground Lead Engineer Sponsor: Matthew Griffin Head of Telecoms (Commercial Development) Summary: This document provides an overview of the Public Cellular Network 4G/LTE trial carried out on the London Underground Waterloo and City line. This testing involved the Waterloo & Bank stations and the connecting tunnels. This testing was supported by Thales, Huawei, Telefonica O2, Vodafone, TfL (LU) Engineering, Public Cellular Project team and the TfL Emergency Services Network Project Team (including Fujitsu Services and Installation Technology). Page 1 of 24 Table of Contents 1. Document Control .......................................................................................................... 3 1.1. Document Control / Change History ........................................................................ 3 1.2. Document References ............................................................................................ 3 1.3. Acronyms and Abbreviations .................................................................................. 3 2. Introduction ...................................................................................................................
    [Show full text]