Att 2 183106ME31800 ROOF HVAC LAYOUT
Total Page:16
File Type:pdf, Size:1020Kb
1 2 3 4 5 6 7 NOTE: • ALL INTERNAL INSULATION FOR ROOF LEVEL AND RISER SHAFT. • EXTERNAL INSULATION AFTER RISER PENETRATION. A VOID TO COMMUNAL OPEN SPACE 500X200 GRABAGE ROOMS EXHAUST DUCT FROM MECHANICAL SWITCHBOARDS BELOW TO DISCHARGE VIA ROOF MOUNTED FAN. BELOW TO BE WEATHERPROOF. B SHELTER TO BE PROVIDED BY PV ARRAYS EXTENT PV ARRAYS EXTENT BUILDER. (INDICATIVE ONLY) (INDICATIVE ONLY) 850x1900 SHAFT SIZE. CONTROL CENTRE FOR GLASS 500x1350 DUCT SIZE LOUVERS FOR LEVEL 1 -17 CORRIDORS. PROVIDE WEATHERPROOF ENCLOSURE. STAIR PRESSURISATION SUPLLY C AIR SYSTEMS, FAN TO HAVE A MSSB-R MSSB-E-1 VSD. NOTES - 1. FOR EACH STAIRWELL, PROVIDE STAIRWELL PRESSURE CONTROLLER D COMPLETE WITH TWO (2) DIFFERENTIAL PRESSURE SENSORS AND CC AVERAGING MODULE. DIFFERENTIAL PRESSURE SENSORS SHALL BE LOCATED AT LEVEL 5 1000x1000 AND LEVEL 14 (ALLOW FOR RELOCATION OF SENSORS TO SUIT). 2. PROVIDE DUCT MOUNTED SMOKE DETECTORS AND CONTROLS FOR GEF-G LIFT SHAFT STAIR PRESSURISATION SYSTEMS TO THE REQUIREMENTS OF 500x1350 OA R3.0 AS1668.1 -2015. NRD ATT-1 3. PROVIDE ACOUSTIC INSULATION TO STAIR PRESSURISATION DUCTWORK INDICATIVE LOCATION S01 D ON THE ROOF. DUCTWORK SHALL BE WEATHERPROOF COMPLETE WITH 800x800 OA R3.0 Section / Elevation A 301 SSL SF-2 STAIR PRESSURISATION SUPLLY CROSS BREAKS. NRD OF FIRE TANKS +82,830 AIR SYSTEMS, FAN TO HAVE A 4. OUTDOOR AIR SUPPLY DUCTS ON THE ROOF SHALL BE ATT-1 1000x1000 PA VSD. WEATHERPROOF TYPE HAVING CROSS BREAKS. 1000x1000 PA E ATT-2 5. ROOF PENETRATIONS SHALL BE PROVIDED WITH 150MM HIGH ROOF ATT-2 1000x1000 CURB BY THE BUILDING TRADE. MECHANICAL SERVICES SHALL OAF-R1 PROVIDE OVER -FLASHINGS OVER THE PENETRATIONS. OAF-R2 ATT-1 SF-1 ATT-1 6. PROVIDE AMBIENT TEMPERATURE SENSORS AND CONTROLLERS FOR ATT-2 ATT-2 1700x1700 R3.0OA THE OPRATION OF BOILERS AND HEATING HOT WATER COILS. 1800x1800 7. CONDENSING BOILERS SHALL BE INCORPORATED WITH IN -BUILT NRD CIRCULATION PUMP, FLOW AND RETURN HEADERS, ISOLATION VALVES NRD AND HYDRAULIC MODULE WITH EXPANSION TANK AND MAKE -UP T WATER CONNECTION INCLUDING HYDRAULIC SEPARATOR. 8. HYDRAULIC SERVICES WILL PROVIDE NATURAL GAS SUPPLY 1800X1800 WEATHEPROOF TERMINATED AT ISOLATION VALVE, MECHANICAL SERVICES SHALL HC -OA 800x800 OA R3.0 LOUVRE WITH BIRD WIRE MESH. CONNECT TO BOILERS COMPLETE WITH GAS TRAIN AND CONDENSATE R3.0 DRAIN PIPE TO DRAIN POINT ON THE ROOF. HWB -1 HYDRAULIC SERVICES SHALL PROVIDE COLD WATER MAKE -UP SUPPLY TERMINATED AT ISOLATION VALVE, MECHANICAL SERVICES SHALL 800x800 OA F CONNECT TO CONDENSING BOILER HYDRAULIC MODULE COMPLETE WITH 2000X2000 WEATHERPROOF CHEMICAL DOSING POT AND PIPEWORK. WEATHERPROOF 1800x1800 OUTDOOR AIR PLENUM OUTDOOR AIR LOUVRE WITH 9. ACOUSTIC CONSULTANT TO CONFIRM SIZE, QUANTITY, TYPE AND HEATING HOT WATER COILS COMPLETE WITH SMOKE DETECTORS CONTROLS, AIR VERMIN PROOF SCREEN 5320 L/s JOB MANAGER:JOB VERIFIER: LOCATION OF ALL ATTENUATORS. FILTER BANK WITH PRESSURE DIFFERENT GUAGES, AMBIENT TEMEPRATURE SENSOR ETC. CASCADED CONDENSING BOILERS TO SERVE HEATING CENTRAL OUTSIDE AIR SYSTEM TO PROVIDE HOT WATER COILS TO TEMPER OUTSIDE AIR FOR ALL APARTMENT BEDROOMS WITH TEMPERED CENTRAL OUTSIDE AIR SYSTEM. OUTSIDE AIR, IN -LINE FAN TO HAVE NON - A TEMPERATURE DIFFERENCE OF 10°C FROM AMBIENT PODDED ATTENUATORS ON BOTH SUPPLY AND AIR IN WINTER IS TARGETED FOR CONDENSER BOILER G.HARRIS G.HARRIS D.CIANCI SUCTION SIDES, WITH A VSD FOR EACH FAN. SIZING. REMOVABLE AIR FILTER BANK COMPRISING 9 OFF DESIGNED: 610X610X100 PLEATED PANEL AIR FILTERS WITH FRAME. A.VLAHIOTIS DRAWN: NOT FOR CONSTRUCTION REV DESCRIPTION ISSUED VER'D APP'D DATE CLIENT ARCHITECT ALL SETOUT TO ARCHITECT'S DRAWINGS. PROJECT DRAWING TITLE JOB NUMBER 1 ISSUE FOR PRICING A.V P.Y 16.04.19 DIMENSIONS TO BE VERIFIED WITH ARCHITECT AND BUILDER BEFORE COMMENCING SHOP DRAWINGS OR 11 GIBBONS STREET MECHANICAL SERVICES SY183106 2 ISSUE FOR PRICING A.V P.Y 03.05.19 SITE WORK. NORTHROP ACCEPTS NO RESPONSIBILITY FOR THE USABILITY, COMPLETENESS OR SCALE OF DRAWING NUMBER 3 ISSUE FOR PRICING A.V P.Y 07.05.19 REDFERN, NSW 2016 ROOF HVAC LAYOUT REVISION DRAWINGS TRANSFERRED ELECTRONICALLY. Sydney 4 REVISED ISSUE FOR PRICING G.H G.H 28.05.19 Level 11, 345 George Street, Sydney, N.S.W. 2000 0 1000 2000 3000 4000 5000 A D&C TENDER P.B G.H 21.06.19 Ph (02) 9241 4188 Email: [email protected] GIB-MD31800 A DRAWINGS NOT TO BE USED FOR CONSTRUCTION UNLESS THE COPYRIGHT OF THIS DRAWING REMAINS WITH NORTHROP ABN 81 094 433 100 VERIFICATION SIGNATURE HAS BEEN ADDED CONSULTING ENGINEERS PTY LTD DRAWING SHEET SIZE = A1.