WRAP Fire Resistant Duct

Total Page:16

File Type:pdf, Size:1020Kb

WRAP Fire Resistant Duct Promat®-WRAP Fire Resistant Duct www.promatmiddleeast.com Promat®-WRAP Fire Resistant Duct Who are we? First choice for passive fire protection Promat Middle East is a subsidiary of Etex Group, a Belgian industrial group manufacturing and marketing high quality building materials across a diverse range of industries globally. Promat Middle East provides a broad and comprehensive range of passive fire protection and insulation solutions within various application for the construction industry - buildings, infrastructure and tunnels, as well as industrial and oil and gas. Promat Middle East is located in Dubai, United Arab Emirates with a 50,000 sqft manufacturing plant based in Dubai Investment Park. This facility supplies products to the United Arab Emirates, Saudi Arabia, Qatar, Kuwait, Oman and the wider Middle East region. Supporting our manufacturing facility we have a highly motivated team of technical professionals dedicated to making the increasingly complex built environment a better place for all to live, work and be successful. Promat entered the Middle East region with the acquisition of Cafco International in 2007. The linkage of the spray fire rated material (SFRM) and the predominantly known Promat worldwide solutions, both tried, tested and proven products, systems and solutions, are today effectively working throughout construction projects in the Middle East. The company has a specialised reputation for bringing high levels of quality fire performance and risk accountability to many different types of fire rated ductwork, compartmentation, structural protection, fire stopping as well as multiple tunnel applications and underground structures. 2 Promat®-WRAP Fire Resistant Duct Building Regulations require that new buildings must be divided into fire compartments and provide means of escape in order that the spread of fire in the building is contained. Obvious areas of weakness include doors, building services, and ventilation ductwork passing from one compartment to another. In particular, the standard ventilation ductwork system offers little or no protection against fire spread, and to overcome this fire resistant ductwork is used. Promat®-WRAP fire duct systems gives ductworkers complete control of both fabrication and installation of fire resistant ducts where required in commercial developments. This assures that the full system is manufactured under strict factory controls to Promat’s required technical standards. All manufacturers of Promat®-WRAP duct systems are re-trained and audited annually by qualified ISO Internal Auditors. Using Promat®-WRAP duct systems puts all elements of a Promat®-WRAP duct systems have been designed around contract in the hands of the ductworker, and allows entry into a the needs of ductworkers, enabling them to manufacture fire specialist market segment, without the need to develop highly resistant ductwork in their own factories without the need for expensive in-house systems. third party suppliers. Full training in the fabrication of fire resistant ductwork is given, and as part of Promat service commitment we work alongside our customers as the ductworker’s technical support department. Promat can deal directly with specifiers and consultants on any queries relating to fire protection, whether at the tender, fabrication, install or sign-off stage. Promat®-WRAP fire ducts are suitable for ventilation, smoke extract, kitchen extract, and pressurisation ductwork systems, offering up to 240min fire resistance when tested to BS 476: Part 24: 1987 (ISO 6944: 1985). Promat®-WRAP fire ducts have passed the required flammability, smoke and toxicity tests required for use in underground metro projects. Tested according to: Approved by: Fire Outside - Duct Type A Assessed by: Fire Inside - Duct Type B 3 Promat®-WRAP Fire Resistant Duct Product Description Promat®-WRAP fire duct systems use Promat®-WRAP fire ducts can be a specially woven fire protection glass constructed as rectangular, oval, circular fibre fabric, which is bonded and or spiral ductwork, manufactured in the mechanically fixed to the outer face of normal manner and broadly following galvanised or stainless steel ductwork, to the requirements of DW144 / SMACNA. achieve the required fire performance. There is usually no requirement to The fabric is less than 0.5 mm thick and upgrade the gauge of steel used to adds virtually nothing to the overall achieve the required fire resistance. weight of the uninsulated steel duct Once the steel duct section has been sections. The insulated Promat®-WRAP formed, the fabric is applied quickly Fire Duct systems add a layer of rock and easily, and bonded to the duct mineral wool. using a contact adhesive. The fabric is mechanically fixed using mild steel rivets The fabric is silver grey in appearance, or screws along a single longitudinal unobtrusive and gives a neat, edge. Flanges are then tapped on and aesthetically pleasing finish. During the fixed mechanically to the duct - no curing finishing process the fabric is overprinted time is required and the duct is then Promat®-WRAP fire duct systems use a with FIRE RESISTANT to ensure it remains ready to transfer to site for installation. independent of standard ventilation glass fibre cloth, bonded directly on to steel ductwork to give fire resistance of up to four ductwork and service trays. hours. Applications Suitable for a wide range of environments, Promat®-WRAP fire Promat fire esistingr ductwork can be used in any area of a ducts have been successfully installed in: building to protect life and property and to aid the emergency services in the event of a fire. Typical areas include: • factories • commercial kitchens • Ventilation ductwork • schools • Smoke extract ductwork systems • hospitals, • Non domestic kitchen extract ductwork • shopping centres • Basement and enclosed car park duct and smoke extract • metro systems systems • Escape route ducts for the purposes of safeguarding life and property from fire. • Pressurisation ductwork systems • Dual ventilation/smoke extract systems Promat®-WRAP fire ducts have passed the required smoke and • Fume cupboard extract systems toxicity tests required for use in underground metro projects. • High risk areas 4 Promat®-WRAP Fire Resistant Duct Promat®-WRAP fire ducts can be fitted as both uninsulated and insulated systems depending upon requirements. Following the guidance in BS9999 installing an uninsulated fire resisting duct system is normally acceptable to the approval authorities when personnel or combustible materials are at least 500 mm from the duct. The fire esistantr duct work system is part of the overall fire protection strategy for a building and will be designed to integrate with other passive and active systems, such as sprinklers. Often fire resisting ducts are expected to be exposed to much lower temperatures than those experienced in a fully developed fires. In this instance Promat®-WRAP uninsulated fire ducts meet the requirements for smoke extract at temperatures of 350° C and kitchen extract for up to 400° C. Thermal or acoustic insulation can be applied to ensure the duct performs in normal operating conditions. Training and Ongoing Support All of Promat’s customers receive full training prior to the fabrication or installation of fire resistant ductwork. The training packageis delivered at the customer’s factory and is a combination of technical presentations, training videos, and hands-on manufacture of Promat®-WRAP fire ducts. Upon completion of training, each company is certificated as an Accredited Installer. An annual training refresher is also given and any changes to the Technical Manual are communicated directly to the customer. Promat recognises that specifiers and building control officers can seem daunting. As it is a safety critical area of the industry, can interpret the requirements around the installation of fire the technical knowledge required can be off-putting. resistant ductwork in different ways. Promat will work directly with contractors, consultants and other key influencers to Promat acts as the ductworker’s in-house technical department, ensure any technical submission meets their requirements. and will answer any questions the ductworker or consultant has regarding fire rated ductwork, and the performance of Promat inspectors will visit the installation of the ductwork on Promat’s range of systems. Our technical team includes some site to ensure it is fitted to the requirements of the Technical of the UK’s leading experts on PFP and Promat’s systems have Manual, and issue a Certificate of Conformity in the name of been designed to be a straightforward addition to the range of the ductworker. services offered by professional ductwork manufacturers. For companies who have not installed fire rated ductwork before, or have limited experience, initial entry into this market Performance Criteria to: BS476: Part 24: 1987 (ISO 6944: 1985) Promat®-WRAP Fire Duct System Stability Integrity Insulation Smoke extract Kitchen extract 60 60 0 30 0 Promat®-WRAP 60 60 60 0 60 0 Promat®-WRAP 60S Promat®-WRAP 60i 60 60 60 30 30 Promat®-WRAP 30K 60 60 60 60 30 Promat®-WRAP 60Si 120 120 0 30 0 Promat®-WRAP 120 120 120 0 120 0 Promat®-WRAP 120S Promat®-WRAP 120i 120 120 120 30 60 Promat®-WRAP 60K 120 120 120 120 60 Promat®-WRAP 120Si 240 240 0 60 0 Promat®-WRAP 240 5 Promat®-WRAP Fire Resistant Duct Case Study Burj Al Arab, Dubai, UAE Burj Al Arab Hotel is an iconic building and is regularly voted the world’s most luxurious hotel. Wrapped Ducts has been used in restaurant refurbishment at the hotel, providing kitchen extract with a fire resistance period of up to 2 hours. In addition, Wrapped Ducts have been installed in many projects in the UAE including hotels, restaurants, schools, malls, substations and towers, and across a wide range of applications including basement car parks, kitchen extract, staircase pressurisation/scape routes and smoke extract. Case Study AQ Towers, Doha, Qatar The Abraj Quartier is the landmark component of a major mixed-use development in Doha known as “The Pearl”. The two towers include 2,200 residential units and a total of more than 350,000 m² of built area.
Recommended publications
  • A Comprehensive Review of Thermal Energy Storage
    sustainability Review A Comprehensive Review of Thermal Energy Storage Ioan Sarbu * ID and Calin Sebarchievici Department of Building Services Engineering, Polytechnic University of Timisoara, Piata Victoriei, No. 2A, 300006 Timisoara, Romania; [email protected] * Correspondence: [email protected]; Tel.: +40-256-403-991; Fax: +40-256-403-987 Received: 7 December 2017; Accepted: 10 January 2018; Published: 14 January 2018 Abstract: Thermal energy storage (TES) is a technology that stocks thermal energy by heating or cooling a storage medium so that the stored energy can be used at a later time for heating and cooling applications and power generation. TES systems are used particularly in buildings and in industrial processes. This paper is focused on TES technologies that provide a way of valorizing solar heat and reducing the energy demand of buildings. The principles of several energy storage methods and calculation of storage capacities are described. Sensible heat storage technologies, including water tank, underground, and packed-bed storage methods, are briefly reviewed. Additionally, latent-heat storage systems associated with phase-change materials for use in solar heating/cooling of buildings, solar water heating, heat-pump systems, and concentrating solar power plants as well as thermo-chemical storage are discussed. Finally, cool thermal energy storage is also briefly reviewed and outstanding information on the performance and costs of TES systems are included. Keywords: storage system; phase-change materials; chemical storage; cold storage; performance 1. Introduction Recent projections predict that the primary energy consumption will rise by 48% in 2040 [1]. On the other hand, the depletion of fossil resources in addition to their negative impact on the environment has accelerated the shift toward sustainable energy sources.
    [Show full text]
  • As One of the Leading Suppliers of Fire Protection
    A DURABLE FIBRE CEMENT & STEEL COMPOSITE BUILDING MATERIAL s one of the leading suppliers of fire protection We, as a company, do not just manufacture products, products and systems world wide, Intumex Asia rather we provide a comprehensive service to achieve the AaPacific are acutely aware of the importance of best solution to specific fire or blast protection problems. product quality and consistency. These factors are critical for all fire protection products and systems as peoples We can offer advice at the design stage, provide lives may depend on them. construction detailing and where necessary, special project orientated product and system testing which will First produced in 1934, DURASTEEL® became part of our enable the manufacture of custom built solutions, tailored product range in 1980. As one of the world leaders and to your needs. specialists in passive fire protection, Intumex Asia Pacific have been instrumental in protecting life, the Our commitment to quality and to continual product and environment and financial investment, and as such offers system research, development and testing enable you to ® systems that are technically advanced and value- specify DURASTEEL systems with confidence. engineered to meet today s market needs. All Intumex products, therefore, are manufactured under We have used our specialist technical and engineering skills accredited EN ISO 9000 quality assurance procedures, to develop fire and blast protection for some of the worlds and our products and systems are extensively tested to most valuable industries. These include major projects for all relevant national standards for fire and impact nuclear power plants, gas terminals, offshore production resistance, and acoustic and thermal insulation.
    [Show full text]
  • Idronics 6: Solar Thermal Combisystems
    Idronics#6 Feat_rev2.indd 1 5/4/10 2:57:56 PM CaleffiCaleffi North North America, America, Inc. Inc. 98503883 South W. Milwaukee 54th Street Rd Franklin,Milwaukee, WI 53132 Wisconsin 53208 T:T: 414.421.1000414.238.2360 F: F: 414.421.2878 414.238.2366 Dear Hydronic Professional, Dear Hydronic Professional, Welcome to the 6th edition of idronics, Caleffi ’s semi-annual design journal Welcomefor hydronic to theprofessionals. 2nd edition of idronics – Caleffi’s semi-annual design journal for hydronic professionals. The global recession has slowed nearly all industries over the past year. TheHowever, 1st edition despite of idronicsdeclines was in construction, released in January solar water 2007 heater and distributed shipments to over 80,000in the US people increased in North 50% America. during 2008.It focused on the topic hydraulic separation. From the feedback received, it’s evident we attained our goal of explaining the benefits andAs more proper and application more HVAC of professionalsthis modern design become technique familiar forwith hydronic solar water systems. heating, many recognize opportunities to extend solar thermal technology A Technical Journal Iffor you combined haven’t domesticyet received hot a water copy andof idronics space heating#1, you applications.can do so by Thissending is a in the attachedtrend our reader parent response Caleffi SpA card, identifi or by ed registering several years online ago at in www.caleffi.us Europe, and is. The from publicationnow a topic willof growing be mailed interest to you here free inof North charge. America. You can For also this download reason, the Caleffi Hydronic Solutions completesolar “combisystems” journal as a PDF was fileselected from our as theWeb topic site.
    [Show full text]
  • Best Practices Manual for Solar Hot Water Systems
    Best Practices Manual for Solar Hot Water Systems Updated: 10-25-2011 Introduction: This manual was developed as a tool to assist solar thermal designers and installers as a guideline to provide the most reliable solar hot-water systems possible. The material presented here is not intended to be used as a list of system requirements or as a type of solar code. Rather, it was assembled with the input of many parties to share lessons learned in the field. It is not inclusive and is a work in progress. This manual was developed in Wisconsin where some parts of the state have over 10,000 heating degree days and where winter temperatures regularly fall below -30°F. In fact, the record coldest temperature recorded in Wisconsin was - 55°F. During the summer, temperatures can rise above 100°F. While most climates are not this severe, the practices outlined in this manual will be helpful for system designs in all cold climates as well as in warm climates. A properly designed solar hot-water system must not only function properly during extreme cold and hot environmental circumstances, it must also be able to safely endure sustained periods of low or no hot water draw without damage or overheating. A best practice is defined as: • A practice that is most appropriate under the circumstances. • A technique or methodology that, through experience and research, has reliably led to a desired or optimum result. Overview: A well-designed solar water heating system that is appropriate for the climate where it is located and is properly installed with appropriate solar rated components will last for many years.
    [Show full text]
  • Firemaster® Fire Protection Systems
    FireMaster ® fire protection systems THERMAL CERAMICS Fire Protection product range Thermal Ceramics FireMaster ® products are used all over the world to protect people and structures against fire. Products FireMaster XLS Blanket The new ultra lightweight fire protection blanket from For more than 30 years, FireMaster insulation materials have Thermal Ceramics. Saving even more weight than FireMaster Marine Plus Blanket utilizing a new, innovative, provided effective fire insulation for structures exposed to cellulosic, low thermal conductivity fibre manufacturing process. hydrocarbon and jet fires in oil & gas, marine, transportation and FireMaster Marine Plus blanket construction industries. Lightweight fire insulation designed for weight sensitive applications. Weight savings of 20 to 30% are typical compared to standard FireMaster blanket and alternative The wide variety of FireMaster Fire Protection Systems are insulation solutions. Systems are available for composite, comprehensively certified and extensively tested to meet national steel and aluminium structures. and international standards, offering our customers the security of FireMaster Marine Plus faced blanket global proven fire performance in various market sectors. Our product FireMaster Marine Plus blanket is available with surface range includes FireMaster Marine Plus blanket developed especially coatings of aluminium or glass cloth. for weight-sensitive applications in offshore and marine featuring: FireMaster Marine Plus water repellent blanket FireMaster Marine Plus blanket is available with a water repellent treatment through the entire blanket thickness to • Lower weight designs that minimise weight inhibit water ingress. contribution to structures FireMaster RES system • Improved, simpler, installation techniques leading A rigid metallic enclosure for jet fire protection of valves, to easier installation actuators and flanges. • Combined fire, thermal and acoustic insulation FireMaster cable tray wrap and explosion resistance FireMaster blanket totally encapsulated in aluminium foil.
    [Show full text]
  • Fire Rated Ductwork and Service Enclosures
    The Passive Fire Protection Handbook The UK’s comprehensive guide to passive ire protection Chapter 6 Fire Rated Ductwork and Service Enclosures AUGUST 2017 The Passive Fire Protection Handbook Contents Chapter 1: Introduction Chapter 2: User guide Chapter 3: Structural Steel Chapter 4: Ceilings, Floors and Roofs Chapter 5: Partitions and External Walls Chapter 6: Fire Rated Ductwork and Service Enclosures 165 Ventilation and Smoke Extraction Ducts ��������������������������������������� 166 Cladding of Existing Sheet Metal Ducts ���������������������������������������������� 171 Self-Supporting Ducts ���������������������������� 172 Promat DURADUCT® LT ������������������������� 175 DURADUCT® SMT Fireblast ������������������ 177 DURADUCT® SR �������������������������������������� 179 Cable Protection �������������������������������������� 180 Cable Protection - External or Internal Fires ���������������������������������������� 184 Service Enclosures ���������������������������������� 185 Horizontal Service Enclosures, Suspended Services ������������������������������� 186 Ventilation and Smoke Extraction Ducts ��������������������������������������� 187 Chapter 7: Penetration Seals Chapter 8: Smoke Barriers and Doors CHAPTER 6: FIRE RATED DUCTWORK AND SERVICE ENCLOSURES Fire Rated Ductwork and Service Enclosures TECHNICAL SERVICES T: 0800 1456033 E: [email protected] 165 The Passive Fire Protection Handbook | 2017 Chapter 6: Fire Rated Ductwork and Service Enclosures Ventilation and Smoke Extraction Ducts FIRE TESTING METHODS
    [Show full text]
  • Att 2 183106ME31800 ROOF HVAC LAYOUT
    1 2 3 4 5 6 7 NOTE: • ALL INTERNAL INSULATION FOR ROOF LEVEL AND RISER SHAFT. • EXTERNAL INSULATION AFTER RISER PENETRATION. A VOID TO COMMUNAL OPEN SPACE 500X200 GRABAGE ROOMS EXHAUST DUCT FROM MECHANICAL SWITCHBOARDS BELOW TO DISCHARGE VIA ROOF MOUNTED FAN. BELOW TO BE WEATHERPROOF. B SHELTER TO BE PROVIDED BY PV ARRAYS EXTENT PV ARRAYS EXTENT BUILDER. (INDICATIVE ONLY) (INDICATIVE ONLY) 850x1900 SHAFT SIZE. CONTROL CENTRE FOR GLASS 500x1350 DUCT SIZE LOUVERS FOR LEVEL 1 -17 CORRIDORS. PROVIDE WEATHERPROOF ENCLOSURE. STAIR PRESSURISATION SUPLLY C AIR SYSTEMS, FAN TO HAVE A MSSB-R MSSB-E-1 VSD. NOTES - 1. FOR EACH STAIRWELL, PROVIDE STAIRWELL PRESSURE CONTROLLER D COMPLETE WITH TWO (2) DIFFERENTIAL PRESSURE SENSORS AND CC AVERAGING MODULE. DIFFERENTIAL PRESSURE SENSORS SHALL BE LOCATED AT LEVEL 5 1000x1000 AND LEVEL 14 (ALLOW FOR RELOCATION OF SENSORS TO SUIT). 2. PROVIDE DUCT MOUNTED SMOKE DETECTORS AND CONTROLS FOR GEF-G LIFT SHAFT STAIR PRESSURISATION SYSTEMS TO THE REQUIREMENTS OF 500x1350 OA R3.0 AS1668.1 -2015. NRD ATT-1 3. PROVIDE ACOUSTIC INSULATION TO STAIR PRESSURISATION DUCTWORK INDICATIVE LOCATION S01 D ON THE ROOF. DUCTWORK SHALL BE WEATHERPROOF COMPLETE WITH 800x800 OA R3.0 Section / Elevation A 301 SSL SF-2 STAIR PRESSURISATION SUPLLY CROSS BREAKS. NRD OF FIRE TANKS +82,830 AIR SYSTEMS, FAN TO HAVE A 4. OUTDOOR AIR SUPPLY DUCTS ON THE ROOF SHALL BE ATT-1 1000x1000 PA VSD. WEATHERPROOF TYPE HAVING CROSS BREAKS. 1000x1000 PA E ATT-2 5. ROOF PENETRATIONS SHALL BE PROVIDED WITH 150MM HIGH ROOF ATT-2 1000x1000 CURB BY THE BUILDING TRADE.
    [Show full text]
  • Passive Fire Protection
    passive fire protection Date of Issue: November 2018 FIREMAC FM Fire Ducts Fire resistant ventilation, kitchen extract, smoke extract & pressurisation ductwork. firemac.com passive fire protection PA FIREMAC FM® Fire Ducts PB firemac.com COMPANY PROFILE Firemac was established in 1989 and has grown to become a major provider of passive fire protection products, both in the UK and internationally. Passive fire protection (PFP) is a key part of the structural integrity and fire safety in a building. PFP contains or slows the spread of a fire through the use of fire resistant ductwork, walls, floors, and doors. Firemac has been at the forefront in product design for the PFP sector for over 25 years, and has extensive experience advising a broad range of clients from solution selection through to designing and installing ductwork protection systems, fire walls and ceilings, and fire resistant services enclosures. Firemac’s market leading product range for ductwork, Firemac FM Firemac Project: Fire Duct systems, has a proven track record in builds in the UK, Queen Elizabeth Hospital, Glasgow the Middle East, Africa, India and Asia. More recently, Firemac has introduced FM Blue – an impact- resisting, steel-faced non combustible board that can be used to form fire resisting walls, ceilings, ducts, and enclosures. As our customers would expect of a company working in safety critical systems Firemac is ISO 9001 registered and Third Party Accredited. Firemac Project: Anfield Stadium, Liverpool FIREMAC FM® Fire Ducts FIREMAC FM FIRE DUCT SYSTEMS Building Regulations require that new buildings must be divided into fire compartments and provide means of escape in order that the spread of fire in the building is contained.
    [Show full text]
  • Promat Ductwork Solutions Technical Services Telephone 01344 381400
    Uniclass EPIC L751:P2:N324 L1:X2:Y421 CI/SfB (57.9) Rf9 (K2) July 2003 DUCTWORK SOLUTIONS l DURADUCT LT® l DURADUCT SMT® l DURADUCT SR® INTRODUCTION TRIED AND TESTED SYSTEMS FOR LIFE SAFETY DURADUCT SMT® and LT® ductwork systems are made from DURASTEEL® sheet; a non-combustible composite of fibre cement, reinforced by mechanically bonded galvanised steel sheeting. DURASTEEL® is highly resistant to moisture and retains its mechanical integrity even 2 when saturated. It will not absorb combustible fluids such as cooking oil in kitchen extract ducts and has exceptional fire resistant qualities. Systems are available which will provide up to four hours protection to suit the demands of modern developments. DURASTEEL® withstands hose stream action and, because of its very low moisture absorption, it can be used externally. It is not susceptible to the damage often caused by moisture or sprinkler activation during the early stages of delivery and installation of a fire-rated ductwork system. DURASTEEL® has a tremendous resistance to impact and has high flexural strength, giving added protection in the early stages of construction and throughout the life of the building. DURADUCT SMT® DURADUCT LT® THE FIT AND FORGET DUCTWORK SYSTEM FOR THE LIFE OF YOUR BUILDING DURADUCT SMT/LT Promat Ductwork Solutions Technical Services Telephone 01344 381400 . Fax 1344 381401 DURADUCT LT® THE NEXT GENERATION OF FIRE RATED DUCTWORK CONSTRUCTION DURADUCT LT® consists of a galvanised steel inner duct overboarded with 6.0mm DURASTEEL® and finishing trim angles. The system is installed using a proprietary flange. The total thickness of standard DURADUCT LT® is nominally 7.5mm.
    [Show full text]
  • DURASTEEL Ducting-AP 12
    a durable fibre cement & steel composite building material ducting Introducing DURASTEEL® Ducting Features General • Fire resistant from either side. Making the right choice of fire resistant ductwork is a minefield when legislative considerations have to be borne in mind, a decision that is further complicated when even • Impact resistant. the phrase “fire resistance” and “fire rated” can have totally different meanings and are • Moisture resistant. sometimes used as performance indicators. • Space-saving. “Fire resistance” can be thought to imply that the duct performance includes all three parameters, Stability, Integrity and Insulation, whilst “fire rated” has no particularly definitive • Complete system. meaning and is often confused with “fire resistance” which has significant implications • Excellent structural strength within the British Standards. This lack of clear definition alone creates a dilemma for and integrity. designers who have to make a choice from sales literature that covers many different • Suitable for internal product types and performances. and external locations. • Maintenance-free. • Can be prefabricated. • Low leakage. • Suitable for Class C pressure differential of -750 Pa and +3,500 Pa. • No dampers needed. • Protects services and maintains fire integrity of compartment walls and floors through which it passes. • Fast track construction methods. Types of Application BS 476 : Part 24: 1987 When interpreting BS 476: Part 24, the standard that relates directly to the performance of • Smoke exclusion. fire ducts, specifiers and designers also have to decide whether Type A (Fire outside only) or Type B (Fire inside and outside) is required. The selection of Type A or Type B will depend on • Smoke extraction. the location of the duct and the type of fire risk in that particular area.
    [Show full text]
  • The Passive Fire Protection Handbook
    V5FPH Cover.qxd 12/11/03 9:00 am Page 1 Uniclass EPIC L5:P2:N32 E:X2:Y421 CI/SfB Rf9 (K2)+(K3) December 2003 NBSPlus The Passive Fire Protection Handbook FIRE RATED DUCTWORK ● Ventilation and Smoke Extraction Ducts ● Cable Protection ● Mechanical and Electrical Service Enclosures 6 VENTILATION & SMOKE EXTRACTION DUCTS The Fire Protection Handbook The relative complexity of any ductwork system which is extract, should also have this criterion for the inner surface of passing through different fire compartments and the relevance the duct within the fire compartment when the duct is exposed of the system’s function in ambient and fire conditions can to external fire (Duct A). make the selection of a suitable ductwork system difficult. For smoke extraction, the guidance in the standard states that This section of the handbook aims to give guidance on the the cross sectional area of a duct required to extract smoke in fire performance requirements of ductwork and offers a wide the event of a fire should not be reduced by more than 25%. range of solutions for proprietary “off the shelf” fire rated ductwork, the protection of steel ductwork and for self- Design Considerations supporting systems using PROMATECT®-L500 and The following points are some of the factors which should VICUCLAD®. be considered when determining the correct specification to ensure a ductwork system will provide the required fire For particularly onerous conditions e.g. where a high performance. Further advice can be obtained from the Promat impact strength is required or for use in aggressive Technical Services Department.
    [Show full text]
  • Performance of HVAC System with Solar Reheat William Hutzel Purdue University
    Purdue University Purdue e-Pubs International High Performance Buildings School of Mechanical Engineering Conference 2010 Performance of HVAC System With Solar Reheat William Hutzel Purdue University Scott iW lson Purdue University Jacob Faiola Purdue University Follow this and additional works at: http://docs.lib.purdue.edu/ihpbc Hutzel, William; Wilson, Scott; and Faiola, Jacob, "Performance of HVAC System With Solar Reheat" (2010). International High Performance Buildings Conference. Paper 4. http://docs.lib.purdue.edu/ihpbc/4 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html 3126, Page 1 PERFORMANCE OF HVAC SYSTEM WITH SOLAR REHEAT William J. Hutzel*, Scott A. Wilson, and Jacob Faiola Department of Mechanical Engineering Technology, Purdue University, West Lafayette, IN, USA 765-494-7528, [email protected] *Corresponding Author ABSTRACT This project demonstrated a method for using solar energy to control humidity in buildings during summer operation. This was accomplished by adding a secondary coil in the reheat position of a small commercial single zone air handler. A water/glycol mixture transferred heat from flat plate solar panels located on the roof of the building to the air handler. Preliminary tests showed that solar energy could replace much of the electric reheat that was used prior to the solar retrofit. This project is significant because the 2007 version of ASHRAE Standard 90.1 “Energy Standard for Buildings Except Low-Rise Residential Buildings” only allows air handling equipment with reheat in certain situations, such as when 75% of the heating energy is from reclaimed or renewable sources.
    [Show full text]