Comparison of Temperature and Enthalpy Controlled Economizer Cycle for All-Air Air-Conditioning Systems in the Mediterranean
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Page 1 OPTIMAL ENERGY MANAGEMENT of HVAC
Page 1 OPTIMAL ENERGY MANAGEMENT OF HVAC SYSTEMS BY USING EVOLUTIONARY ALGORITHM Session Number: CIB T2S5 Authors Fong K F, BEng, MSc, CEng, MCIBSE, MHKIE, MASHRAE Hanby V I, BSc, PhD, CEng, MInstE, MCIBSE Chow T T, PhD, CEng, MIMechE, MCIBSE, FHKIE, MASHRAE Abstract The available plant and energy simulation packages become robust and user-friendly, and this is the major reason that they are so popular even in the consultancy fields in these few years. In fact, these plant and energy simulation packages can be widely adopted in studying different alternatives of the operation of HVAC and building services systems. Since there are many parameters involved in different equipment and systems, one of the useful areas of studies is to optimize the essential parameters in order to provide a satisfactory solution for design or operation in terms of efficient and effective facilities management. Therefore in this paper, the simulation-optimization approach is proposed for effective energy management of HVAC systems. Due to the complexity of the HVAC systems, which commonly include the refrigeration, water and air side systems, it is necessary to suggest optimal conditions for different operation according to the dynamic cooling load requirements throughout a year. A simulation-EA coupling suite has been developed by using the metaheuristic skill, and the evolutionary algorithm can be effectively used to handle the discrete, non-linear and highly constrained characteristics of the typical HVAC and building services optimization problems. The effectiveness of this simulation-EA coupling suite has been demonstrated through the establishment of the monthly optimal reset scheme of the chilled water supply temperature of a local central chiller plant. -
VAV Systems, on the Other Hand, Are Designed to Simultaneously Meet a Variety of Cooling and Heating Loads in a Relatively Efficient Manner
PDHonline Course M252 (4 PDH) HVAC Design Overview of Variable Air Volume Systems Instructor: A. Bhatia, B.E. 2012 PDH Online | PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.PDHonline.org www.PDHcenter.com An Approved Continuing Education Provider www.PDHcenter.com PDH Course M252 www.PDHonline.org HVAC Design Overview of Variable Air Volume Systems A. Bhatia, B.E. VARIABLE AIR VOLUME SYSTEMS In central air conditioning systems there are two basic methods for delivering air to the conditioned space 1) the constant air volume (CAV) systems and 2) the variable air volume (VAV) systems. As the name implies, constant volume systems deliver a constant air volume to the conditioned space irrespective of the load with the air conditioner cycling on and off as the load varies. The fan may or may not continue to run during the off cycle. VAV systems, on the other hand, are designed to simultaneously meet a variety of cooling and heating loads in a relatively efficient manner. The system achieves this by varying the distribution of air depending on the cooling or heating loads of each area. The air flow variation allows for adjusting the temperature in a single zone without changing the temperature of air in the whole system, minimizing any instances of overcooling or overheating. This flexibility has made this one of the most popular HVAC systems for large buildings with varying conditioning needs such as office buildings, schools, or apartments. How a VAV system works? What distinguishes a variable air volume system from other types of air delivery systems is the use of a variable air volume box in the ductwork. -
Ene04 Low Carbon Design Low and Zero Carbon Technologies
Ene04 Low carbon design Low and zero carbon technologies Actions: i. Implement LZC (low and zero carbon) technologies in-line with the LZC feasibility study ii. Implement passive design measures and free cooling technologies in line with the previous analysis undertaken Recognised local LZC technologies Technologies eligible to contribute to achieving the criteria must produce energy from renewable sources and meet all other ancillary requirements as defined by Directive 2009/28/EC. Local does not have to mean on site – community schemes near to the site can be used as a way of demonstrating compliance. The following requirements must also be met: 1. There must be a direct supply of energy produced to the building under assessment. 2. Technologies under 50 kWe or 45 kWth must be certified by a Microgeneration Certification Scheme (MCS), or equivalent, and installed by MCS (or equivalent) certified installers. 3. Combined heat and power (CHP) schemes above 50 kWe must be certified under the CHPQA standard. CHP schemes fuelled by mains gas are eligible to contribute to performance against this issue. 4. Heat pumps can only be considered as a renewable technology when used in heating mode. Refer to Annex VI of Directive 2009/28/EC for more detail on accounting for energy from heat pumps. 5. Where MCS or CHPQA certification is not available, the design team must investigate the availability of alternative accreditation schemes in line with the Directives listed above, or an equivalent country or regional directive or standard. Where an accreditation scheme exists, it should be used for the purpose of verifying compliance of the specified LZC technology. -
Demand-Response Management of a District Cooling Plant of a Mixed Use City Development
Demand-Response Management of a District Cooling Plant of a Mixed Use City Development Segu Madar Mohamed Rifai Master of Science Thesis KTH - Royal Institute of Technology School of Industrial Engineering and Management Department of Energy Technology SE-100 44 STOCKHOLM Thesis Registration No.: EGI- 2012-011MSC Title: Demand-Response Management of a District Cooling Plant of a Mixed Use City Development. SEGU MADAR MOHAMED RIFAI Student Number: 731222 A-315 Approved Examiner Supervisor at KTH Date: 05/06/2012 Prof. Björn Palm Dr. Samer Sawalha Local Supervisor Dr. Hari Gunasingam Commissioner Contact person i | P a g e Abstract Demand for cooling has been increasing around the world for the last couple of decades due to various reasons, and it will continue to increase in the future particularly in developing countries. Traditionally, cooling demand is met by decentralised electrically driven appliances which affect energy, economy and environment as well. District Cooling Plant (DCP) is an innovative alternative means of providing comfort cooling. DCP is becoming an essential infrastructure in modern city development owning to many benefits compared to decentralized cooling technology. Demand Response Management (DRM) is largely applied for Demand Side management of electrical grid. Demand of electrical energy is closely connected with the demand of alternative form of energy such as heating, cooling and mechanical energy. Therefore, application of DR concept should be applied beyond the electrical grid; in particular, it could be applied to any interconnected district energy systems. District Cooling Plant is one of a potential candidate and Demand Response management solutions can be applied to DCP for sustainable operation. -
Free Cooling – Outside Air Economizer White Paper #11
FREE COOLING – OUTSIDE AIR ECONOMIZER WHITE PAPER #11 It’s like opening a window when it’s hot inside and cool outside. How much does it save? The easy answer is ‘it depends.’ To really find out, read further. You’ll see there are a lot of factors. Like all heat recovery concepts, a pre-requisite for success is to have the free heat (or free cooling) available at the same location and time as there is a need for it. The free heat in Atlanta has no practical use in Alaska because they are too far apart. Likewise, free cooling from outdoors doesn’t provide any value unless it is warm indoors at that time. Balance Temperature Buildings are like boxes. They have thermal losses and gains through the shell (envelope), and they also have appliances and activities inside that generate heat. See Figure 1. There will be a point where the envelope loss just matches the internal heat gains and neither heating nor cooling is required; above this ‘balance temperature’, cooling will be required. Source: Commercial Energy Auditing Reference Handbook, 3e Doty,S., Fairmont Press. Figure 1. Thermal Balance Temperature FREE COOLING – OUTSIDE AIR ECONOMIZER White Paper What is your building’s balance temperature? A building’s thermal balance temperature can be estimated with a method called regression, but there are also clues. See Table 1. If there is a lot of heat-producing equipment inside, the building becomes self- heating and will include hours in cooling mode when it is cold outside. Opportunity! If the heating and cooling load is mostly from envelope (not a lot of equipment), the balance point will be higher which means it probably won’t be hot inside while it is cold outside. -
A Comprehensive Review of Thermal Energy Storage
sustainability Review A Comprehensive Review of Thermal Energy Storage Ioan Sarbu * ID and Calin Sebarchievici Department of Building Services Engineering, Polytechnic University of Timisoara, Piata Victoriei, No. 2A, 300006 Timisoara, Romania; [email protected] * Correspondence: [email protected]; Tel.: +40-256-403-991; Fax: +40-256-403-987 Received: 7 December 2017; Accepted: 10 January 2018; Published: 14 January 2018 Abstract: Thermal energy storage (TES) is a technology that stocks thermal energy by heating or cooling a storage medium so that the stored energy can be used at a later time for heating and cooling applications and power generation. TES systems are used particularly in buildings and in industrial processes. This paper is focused on TES technologies that provide a way of valorizing solar heat and reducing the energy demand of buildings. The principles of several energy storage methods and calculation of storage capacities are described. Sensible heat storage technologies, including water tank, underground, and packed-bed storage methods, are briefly reviewed. Additionally, latent-heat storage systems associated with phase-change materials for use in solar heating/cooling of buildings, solar water heating, heat-pump systems, and concentrating solar power plants as well as thermo-chemical storage are discussed. Finally, cool thermal energy storage is also briefly reviewed and outstanding information on the performance and costs of TES systems are included. Keywords: storage system; phase-change materials; chemical storage; cold storage; performance 1. Introduction Recent projections predict that the primary energy consumption will rise by 48% in 2040 [1]. On the other hand, the depletion of fossil resources in addition to their negative impact on the environment has accelerated the shift toward sustainable energy sources. -
Controlling Airflow in Class II Biosafety Cabinets
Controlling Airfl ow in Class II Biosafety Cabinets by Jim Hunter, Senior Project Engineer, Mark Meinders, Product Manager, and Brian Garrett, Product Specialist, Labconco Corporation Introduction Class II biosafety cabinets are defi ned by the National Sanitation Founda- tion (NSF International) as: “A ventilated cabinet for personnel, product, and environmental protec- tion having an open front with inward airfl ow for personnel protection, downward HEPA fi ltered laminar airfl ow for product protection, and HEPA fi ltered exhausted air for environmental protection.”1 In order to maintain proper containment, NSF stipulates that recircu- lating and exhausted airfl ow volumes, and therefore velocities, must be maintained within a tolerance of +/- 5 feet per minute (FPM).2 HEPA fi lter loading can compromise a biological safety cabinet’s ability to maintain proper airfl ow. This paper will review the current technologies used by various biosafety cabinet manufacturers to monitor and maintain proper airfl ows as HEPA fi lters load. Manually Controlling Airfl ow Differential Pressure Gauges When biosafety cabinets were originally developed in the 1960s and 70s, ® ® built-in electronic technologies for measuring and displaying airfl ow were The Purifi er Logic Biosafety Cabinet is one example of a biologi- cal safety cabinet that uses sensorless airfl ow control. prohibitively expensive. To indicate that the cabinet was running prop- erly, most manufacturers opted to equip their cabinets with differential pressure gauges. The differential pressure gauge simply reports the pres- readings may not be intuitive and since most gauges do not have an sure change between points. The most commonly used gauge is known by alarm to indicate a performance failure, there is potential for users to be the trade name Magnehelic™, manufactured by Dwyer Instruments Incor- exposed to unsafe conditions before performance is restored. -
Extract from the Proceedings of Building Simulation and Optimization 2012
First Building Simulation and Optimization Conference Loughborough, UK BSO12 10-11 September 2012 MODELING AND SIMULATION OF BUILDING ECONOMIZER AND ENERGY RECOVERY SYSTEMS FOR OPTIMUM PERFORMANCE Stephen Treado, Xing Liu Pennsylvania State University University Park, PA appropriate to provide “free cooling”, the rough ABSTRACT equivalent of opening the windows on a nice day This paper describes how building economizer and rather than using mechanical cooling. The former energy/enthalpy recovery system control and study has demonstrated that the energy savings operation can be modelled and simulated to evaluate associated with economizer could be very significant and optimize their performance. A improved method (Brandemuehl et al., 1999). The energy saving of the to determine optimum temperature setpoints and robust control strategy on cooling coil energy outdoor air fractions is discussed and demonstrated. consumption which was evaluated by over one year’s Through the simulation, the new strategy based on comparison tests on two air-handling units in a total system energy use is shown to be able to save building was 88.47% in contrast to the energy up to 11% of energy under certain conditions and to consumption using the conventional control (damper be most useful for dry climates. at fixed position) in Hong Kong (Wang et al., 2004). Energy recovery systems exploit the “free heating or INTRODUCTION cooling” provided by exchanging energy between the exhaust and outdoor airstreams. In both of these Buildings are constructed to serve a purpose, namely systems, some control logic must be implemented to to provide a comfortable, safe, healthy and determine how and when the systems should be productive environment for human endeavours. -
Hvacwatersystems Waterside Free Cooling.Pdf
HVAC Water Systems Waterside Free Cooling Summary Free cooling utilizes the evaporative cooling capacity of a cooling tower to indirectly produce chilled water for use in medium temperature loops, such as process cooling loops and sensible cooling loops. Free cooling is best suited for climates that have wetbulb temperatures lower than 55°F for 3,000 or more hours per year. It is most effectively applied to serve process and/or sensible cooling loops that between 50°F–70°F chilled water. Table 1. Free Cooling Application At least 3000 hours per Applicability year where wet bulb temperature is below: 55°F Process cooling water Process cooling, sensible 45°F cooling 35°F All chilled water use 1. Assumes process cooling water is between 60 to 70°F. 2. Assumes sensible cooling water is between 50 to 55°F. Principles • Chilled water systems use chillers that typically operate at 0.5 to 0.7 kW/ton in a partial load regime while free cooling systems typically operate at 0.05 to 0.15 kW/ton. 1 • A flat plate heat exchanger is used to isolate the chilled water loop from the open tower condenser water. With few exceptions, tower water is not reliably clean enough for use directly in the cooling loop. • The approach temperature on a cooling tower is critical for best results. A low approach temperature on the tower is critical to achieve the highest energy savings. • A traditional chiller is used to provide cooling during hot periods and as an always-available emergency backup. For a portion of the year, free cooling offers a non-compressor based backup to the traditional chiller. -
Melink Intelli-Hood Snapshot of 4 Melink Customers a New Standard in Kitchen Ventilation Intelli-Hood Kitchen Ventilation Controls
®® Case Studies Melink Intelli-Hood Snapshot of 4 Melink customers A New Standard in Kitchen Ventilation Intelli-Hood Kitchen Ventilation Controls Savings & Benefits Other Intelli-Hood® Advantages Improves Energy Efficiency ® The Intelli-Hood controls improve energy efficiency 1. Eliminate drive losses and belt Supermarket Restaurant Hotel University by reducing the exhaust and make-up fan speeds during maintenance by specifying direct Annual energy savings Annual energy savings Annual energy savings idle periods. Typical annual operating savings are Annual energy savings drive fans. per location per location per location per location $1,500-$3,000 per hood, with a payback of 1-3 years. $2,340 $2,040 $5,500 $5,580 2. Reduce humidity problems associated Improves Kitchen Comfort ® with a negative building pressure. Current payback Current payback Current payback Current payback The Intelli-Hood controls improve kitchen comfort 1.8 years 2.2 years 2.1 years 2.3 years by reducing the supply of hot/humid make-up air during 3. Improve hood and building air idle periods. They also serve as an economizer when balance with variable-speed controls indoor and outdoor conditions are right for free cooling. Finally, the Intelli-Hood® controls reduce hood noise in the (verses belts and pulleys). kitchen up to 90% when the fans slow down. 4. Extend HVAC equipment life by Before-and-After Energy Savings Improves Fire Safety reducing run time and thus wear/tear The Intelli-Hood® controls can improve fire safety by of compressors, motors, heaters, etc. KW with the Intelli-Hood® monitoring the exhaust air temperature. If the temperature Actual reading from a current Intelli-Hood supermarket ® 5. -
Reverse Flow Fan Filter Units Models: 92Ffu-Rf and 92Ffum-Rf
MEETING THE NEED FOR COVID-19 PATIENT ISOLATION ROOMS WITH REVERSE FLOW FAN FILTER UNITS MODELS: 92FFU-RF AND 92FFUM-RF According to the ASHRAE Standard 170, all Airborne Infection Isolation (AII) Our Reverse Flow FFU’s create negative pressure environments that remove rooms should be kept at a negative static pressure at all times to prevent the air from an isolation room and clean it via the unit’s built-in HEPA filter, the spread of infected air to the rest of the building. To accomplish this, the which keeps airborne contaminants from escaping the room. These units are exhaust air should be filtered and exceed the supply air. However, in most the most powerful available, featuring... cases, the central exhaust will not be able to accommodate HEPA filtration. • The industry’s highest output, up to 1125 CFM Therefore, using a Reverse Flow Fan Filter Unit (FFU) with HEPA filter can keep the • Energy efficiency (only 65 watts at 90 FPM velocity/450 CFM) room at negative pressure and decontaminate the exhaust air at the same time. • Quiet performance (only 45 DBA at 90 FPM, 58 DBA at 1100 CFM) Nailor has played an important role in helping hospitals provide critical • Ceiling-mount version has the industry’s lowest plenum height – just 16” environment patient isolation care – from the Ebola outbreak of 2014 to the for easier retrofits current COVID-19 pandemic – with our Critical Environment products. • Standard and High Flow HEPA and ULPA filter options Nailor’s Reverse Flow - Fan Filter Units are available in both ceiling-mounted • Ducted and non-ducted versions are available and portable models, making it easier to quickly convert existing spaces into patient isolation rooms. -
Echnica L Ssista Nce Tu Dy Umass Memorial Medical Center
UMASS MEMORIAL MEDICAL CENTER POWER PLANT 55 LAKE AVENUE NORTH WORCESTER, MA T ECHNICAL ECHNICAL A SSISTANCE SSISTANCE PREPARED FOR S TUDY DCAMM Prepared by B2Q Associates, Inc. Andover, MA Revision Date 12/21/2015 TECHNICAL ASSISTANCE STUDY - WATERSIDE ECONOMIZER UMASS MEMORIAL MEDICAL CENTER - POWER PLANT Introduction .................................................................................................................................... 3 Contacts .......................................................................................................................................... 5 Approach & Modeling Methodology .............................................................................................. 6 Executive Summary Table ............................................................................................................... 7 Facility & Process Description ......................................................................................................... 8 Annual Chilled Water Load Profile ................................................................................................ 11 Energy Modeling Methodology .................................................................................................... 15 Baseline Chiller Plant Modeling ................................................................................................ 15 Power Plant Modeling............................................................................................................... 17 Energy Conservation