Environmental Protection Agency Pt. 82, Subpt. B, App. B

Total Page:16

File Type:pdf, Size:1020Kb

Environmental Protection Agency Pt. 82, Subpt. B, App. B Environmental Protection Agency Pt. 82, Subpt. B, App. B 5.5 If the container pressure is less than Application the Table 1 values and has been recycled, limits of noncondensable gases (air) have not During service of mobile air-conditioning been exceeded and the refrigerant may be systems, containment of the refrigerant is used. important. This procedure provides service guidelines for technicians when repairing ve- 5.6 If the pressure is greater than the hicles and operating equipment defined in range and the container contains recycled SAE J1990. material, slowly vent from the top of the container a small amount of vapor into the Committee Composition recycle equipment until the pressure is less than the pressure shown on Table 1. Developed by the SAE Defrost and Interior 5.7 If the container still exceeds the pres- Climate Control Standards Committee sure shown on Table 1, the entire contents of the container shall be recycled. W.J. Atkinson, Sun Test Engineering, Para- dise Valley, AZ—Chairman 6. Containers for Storage of Recycled J.J. Amin, Union Lake, MI Refrigerant H.S. Andersson, Saab Scania, Sweden 6.1 Recycled refrigerant should not be P.E. Anglin, ITT Higbie Mfg. Co., Rochester, salvaged or stored in disposable refrigerant MI containers. This is the type of container in R.W. Bishop, GMC, Lockport, NY which virgin refrigerant is sold. Use only D.Hawks, General Motors Corporation, Pon- DOT CFR title 49 or UL approved storage tiac, MI containers for recycled refrigerant. J.J. Hernandez, NAVISTAR, Ft. Wayne, IN 6.2 Any container of recycled refrigerant H. Kaltner, Volkswagen AG, Germany, Fed- that has been stored or transferred must be eral Republic checked prior to use as defined in section 5. D.F. Last, GMC, Troy, MI D.E. Linn, Volkswagen of America, Warren, 7. Transfer of Recycled Refrigerant MI 7.1 When external portable containers are J.H. McCorkel, Freightliner Corp., Charlotte, used for transfer, the container must be NC evacuated at least 27 in of vacuum (75 mm C.J. McLachlan, Livonia, MI Hg absolute pressure) prior to transfer of the H.L. Miner, Climate Control Inc., Decatur, recycled refrigerant. External portable con- IL tainers must meet DOT and UL standards. R.J. Niemiec, General Motors Corp., Pontiac, 7.2 To prevent on-site overfilling when MI transferring to external containers, the safe N. Novak, Chrysler Corp., Detroit, MI filling level must be controlled by weight S. Oulouhojian, Mobile Air Conditioning So- and must not exceed 60% of container gross ciety, Upper Darby, PA weight rating. J. Phillips, Air International, Australia 8. Disposal of Empty/Near Empty Containers R.H. Proctor, Murray Corp., Cockeysville, MD 8.1 Since all the refrigerant may not be G. Rolling, Behr America Inc., Ft. Worth, TX removed from disposable refrigerant con- C.D. Sweet, Signet Systems Inc., tainers during normal system charging pro- Harrodsburg, KY cedures, empty/near empty container con- tents should be reclaimed prior to disposal of J.P. Telesz, General Motors Corp., Lockport, the container. NY 8.2 Attach the container to the recovery unit and remove the remaining refrigerant. APPENDIX B TO SUBPART B OF PART 82— When the container has been reduced from a STANDARD FOR RECOVER EQUIPMENT pressure to a vacuum, the container valve can be closed. The container should be SAE J1989, Recommended Service Proce- marked empty and is ready for disposal. dure for the Containment of R–12, as set forth under Appendix A, also applies to this Rationale Appendix B. SAE J2209, issued June, 1992. Not applicable. SAE RECOMMENDED PRACTICE: CFC-12 (R–12) Relationship of SAE Standard to ISO Standard. EXTRACTION EQUIPMENT FOR MOBILE AUTO- Not applicable. MOTIVE AIR-CONDITIONING SYSTEMS Reference Section Foreword SAE J1990, Extraction and Recycle Equip- CFCs deplete the stratospheric ozone layer ment for Mobile Automotive Air-Condi- that protects the earth against harmful ul- tioning Systems traviolet radiation. To reduce the emissions 675 VerDate Mar<15>2010 15:27 Sep 13, 2011 Jkt 223160 PO 00000 Frm 00685 Fmt 8010 Sfmt 8002 Q:\40\40V17.TXT ofr150 PsN: PC150 Pt. 82, Subpt. B, App. B 40 CFR Ch. I (7–1–11 Edition) of CFCs, the 1990 Clean Air Act requires re- 3. Specifications and General Description cycle of CFC-12 (R–12) used in mobile air-con- 3.1 The equipment must be able to extract ditioning systems to eliminate system vent- CFC-12 from a mobile air-conditioning sys- ing during service operations. SAE J1990 es- tem. tablishes equipment specifications for on- 3.2 The equipment discharge or transfer site recovery and reuse of CFCs in mobile fitting shall be unique to prevent the unin- air-conditioning systems. Establishing ex- tentional use of extracted CFC-12 to be used traction equipment specifications for CFC-12 for recharging auto air conditioners. will provide service facilities with equipment 3.3 The equipment shall be suitable for to assure that venting of refrigerant will not use in an automotive service garage environ- occur. ment as defined in 6.8. 1. Scope 3.4 Equipment Certification—The equip- ment must be certified by Underwriters Lab- The purpose of this document is to provide oratories or an equivalent certifying labora- equipment specifications for CFC-12 (R–12) tory to meet this standard. recovery for recycling on-site or for trans- 3.5 Label Requirements—The equipment port off-site to a refrigerant reclamation fa- shall have a label ‘‘Design Certified by (com- cility that will process it to ARI (Air-Condi- pany name) to meet SAE J2209 for use with tioning and Refrigeration Institute) standard CFC-12. The refrigerant from this equipment 700–93 as a minimum. It is not acceptable must be processed to ARI 700–93 specifica- that the refrigerant removed from a mobile tions before reuse in a mobile air-condi- air-conditioning system, with this equip- tioning system.’’ The minimum letter size ment, be directly returned to a mobile air- shall be bold type 3mm in height. conditioning system. This information applies to equipment 4. Safety Requirements used to service automobiles, light trucks, and other vehicles with similar CFC-12 sys- 4.1 The equipment must comply with ap- tems. plicable federal, state and local requirements on equipment related to the handling of R–12 2. References material. Safety precautions or notices or labels related to the safe operation of the 2. Applicable Documents—The following equipment shall also be prominently dis- documents form a part of this specification played on the equipment and should also to the extent specified herein. state ‘‘CAUTION—SHOULD BE OPERATED 2.1.1 SAE Publications—Available from BY CERTIFIED PERSONNEL.’’ The safety SAE, 400 Commonwealth Drive, Warrendale, identification shall be located on the front PA 15096–0001. near the controls. SAE J639—Vehicle Service Coupling 4.2 The equipment must comply with ap- SAE J1990—Extraction and Recycle Equip- plicable safety standards for electrical and ment for Mobile Automotive Air-Condi- mechanical requirements. tioning Systems SAE J2196—Service Hose for Automotive 5. Operating Instructions Air-Conditioning 5.1 The equipment manufacturer must 2.1.2 ARI Publications—Available from provide operating instructions, necessary Air-Conditioning and Refrigeration Insti- maintenance procedures and source informa- tute, 1501 Wilson Boulevard, Sixth Floor, Ar- tion for replacement parts and repair. lington, VA 22209. 5.2 The equipment must prominently dis- ARI 700–93—Specifications for Fluorocarbon play the manufacturer’s name, address and Refrigerants any items that require maintenance or re- 2.1.3 CGA Publications—Available from placement that affect the proper operation CGA, Crystal Gateway #1, Suite 501, 1235 Jef- of the equipment. Operation manuals must ferson Davis Highway, Arlington, VA 22202. cover information for complete maintenance CGA S–1.1—Pressure Relief Device Standard of the equipment to assure proper operation. Part 1—Cylinders for Compressed Gases 6. Functional Description 2.1.4 DOT Specifications—Available from the Superintendent of Documents, U.S. Gov- 6.1 The equipment must be capable of en- ernment Printing Office, Washington, DC suring recovery of the CFC-12 from the sys- 20402. tem being serviced, by reducing the system pressure to a minimum of 102 mm of mercury 49 CFR, Section 173.304—Shippers—General below atmospheric. To prevent system de- Requirements for Shipments and Pack- layed outgassing, the unit must have a de- agings vice that assures that the refrigerant has 2.1.5 UL Publications—Available from Un- been recovered from the air-conditioning derwriters Laboratories, 333 Pfingsten Road, system. Northbrook, IL 60062–2096. 6.1.1 Testing laboratory certification of UL 1769—Cylinder Valves the equipment capability is required which 676 VerDate Mar<15>2010 15:27 Sep 13, 2011 Jkt 223160 PO 00000 Frm 00686 Fmt 8010 Sfmt 8002 Q:\40\40V17.TXT ofr150 PsN: PC150 Environmental Protection Agency Pt. 82, Subpt. B, App. C shall process contaminated refrigerant sam- moved from the system during processing in ples at specific temperatures. 30 ml units. 6.2 The equipment must be preconditioned 6.7.1 The purpose of indicating the with 13.6 kg of the standard contaminated amount of lubricant removed is to ensure CFC-12 at an ambient of 21 °C before starting that a proper amount is returned to the mo- the test cycle. Sample amounts are not to bile air-conditioning system for compressor exceed 1.13 kg with sample amounts to be re- lubrication. peated every 5 minutes. The sample method 6.7.2 Refrigerant dissolved in this lubri- fixture defined in Figure 1 of appendix A cant must be accounted for to prevent sys- shall be operated at 24 °C. Contaminated tem lubricant overcharge of the mobile air- CFC-12 samples shall be processed at ambi- conditioning system.
Recommended publications
  • AHRI Project 8018 Final Report
    AHRI Project 8018 Final Report Review of Refrigerant Management Programs Prepared for: Navigant Consulting, Inc. 77 South Bedford St. Suite 400 Burlington, MA 01803 781.270.0101 navigant.com Reference No.: 180019 January 2016 © 2016 AHRI. Table of Contents Acronyms, Abbreviations, and Definitions ....................................................................... vii Executive Summary ................................................................................................................... 1 Research Summary ........................................................................................................................................ 1 Program Effectiveness ................................................................................................................................... 4 Best Practices .................................................................................................................................................. 5 Recommendations ......................................................................................................................................... 7 1. Introduction .......................................................................................................................... 10 1.1 Background ............................................................................................................................................. 10 1.2 Objective .................................................................................................................................................
    [Show full text]
  • GEF Impact Evaluation of the Phase-Out of Ozone-Depleting Substances in Countries with Economies in Transition
    65338 v2 GEF Evaluation Office GEF IMPACT EVALUATION Public Disclosure Authorized GEF IMPACT EVALUATION Public Disclosure Authorized Impact Evaluation Information Document No. 18 GEF Impact Evaluation of the Phase-Out of Ozone-Depleting Substances in Countries with Economies in Transition. Volume Two: Country Reports Public Disclosure Authorized October 2009 Public Disclosure Authorized This paper is an input into the GEF Evaluation Office (GEF EO) program of Impact Evaluation. The findings, interpretations, and conclusions expressed herein are those of the authors and do not necessarily represent the views of GEF Evaluation Office, the GEF Council, or the Governments they represent. The papers in the Impact Evaluation information document series are: 1. Approach Paper to GEF Impact Evaluation – Brann and Todd 2. Final Report on Proposed Approach to GEF Impact Evaluation - Foundations of Success 3. GEF Biodiversity Policy Review - Foundations of Success 4. Methodological Challenges in Impact Evaluation: The Case of the Global Environment Facility – Todd and Vaessen 5. Priorities and indicators for Global Environment Benefits from Biodiversity: The current international architecture – Nair 6. Case Study Methodology – Conservation Development Centre 7. Case Study: Bwindi Impenetrable National Park and Mgahinga Gorilla National Park Conservation Project - Conservation Development Centre 8. Case Study: Lewa Wildlife Conservancy – Conservation Development Centre 9. Case Study: Reducing Biodiversity Loss at Cross-Border Sites in East Africa Conservation Development Centre 10. Impacts of Creation and Implementation of National Parks and of Support to Batwa on their Livelihoods, Well-Being and Use of Forest Products – Namara 11. Protected Areas and Avoided Deforestation: A Statistical Evaluation – Andam, Ferraro, Pfaff and Sanchez-Azofeifa 12.
    [Show full text]
  • Refrigerant Management Program
    BY ORDER OF THE AIR FORCE MANUAL 32-7089 SECRETARY OF THE AIR FORCE 4 NOVEMBER 2016 Civil Engineering REFRIGERANT MANAGEMENT PROGRAM COMPLIANCE WITH THIS PUBLICATION IS MANDATORY ACCESSIBILITY: Publications and forms are available for downloading or ordering on the e-Publishing website at www.e-Publishing.af.mil. RELEASABILITY: There are no releasability restrictions on this publication. OPR: AF/A4CF Certified by: HQ USAF/A4C (Maj Gen Timothy Green) Supersedes: AFPAM 32-7089, 14 June 2013 Pages: 51 This manual implements Air Force Policy Directive (AFPD) 32-10, Installations and Facilities, and Title 40, Code of Federal Regulations (CFR), Part 82, Protection of Stratospheric Ozone. It describes the Air Force policy for managing refrigerants used in real property equipment and does not apply to refrigerants used in motor vehicle air conditioning (MVAC) or aircraft refrigeration systems. This manual applies to all Air Force Active, Reserve, Guard, civilian and contractor personnel who develop, acquire, deliver, use, operate, or manage refrigerants used in Air Force real property equipment. Direct questions, comments, recommended changes, or conflicts to this manual through command channels, using the AF Form 847, Recommendation for Change of Publication, through the appropriate functional chain of command. The authorities to waive wing/unit level requirements in this publication are identified with a Tier (“T-0, T-1, T- 2, T-3”) number following the compliance statement. See AFI 33-360, Publications and Forms Management, Table 1.1, for a description of the authorities associated with the Tier numbers. Submit requests for waivers through the chain of command to the appropriate Tier waiver approval authority, or alternately, to the publication OPR for non-tiered compliance items.
    [Show full text]
  • IN the UNITED STATES COURT of APPEALS for the DISTRICT of COLUMBIA CIRCUIT NATURAL RESOURCES DEFENSE COUNCIL, INC., Petitioner
    IN THE UNITED STATES COURT OF APPEALS FOR THE DISTRICT OF COLUMBIA CIRCUIT NATURAL RESOURCES DEFENSE COUNCIL, INC., Petitioner, v. Case No. _______ ANDREW WHEELER, Administrator, U.S. Environmental Protection Agency, and UNITED STATES ENVIRONMENTAL PROTECTION AGENCY, Respondents. PETITION FOR REVIEW of a final rule of the U.S. Environmental Protection Agency Pursuant to Clean Air Act § 307(b)(1), 42 U.S.C. § 7607(b)(1), Rule 15 of the Federal Rules of Appellate Procedure, and D.C. Circuit Rule 15, the Natural Resources Defense Council hereby petitions the Court for review of the final rule of Respondents Andrew Wheeler, Administrator, U.S. Environmental Protection Agency (EPA), and EPA, titled “Protection of Stratospheric Ozone: Revisions to the Refrigerant Management Program’s Extension to Substitutes.” This rule was published in the Federal Register at 85 Fed. Reg. 14,150 on March 11, 2020. A copy of the rule is attached as Exhibit A. Dated: May 11, 2020 Respectfully submitted, /s/ Melissa J. Lynch Melissa J. Lynch David D. Doniger Natural Resources Defense Council 1152 15th Street NW, Ste. 300 Washington, DC 20005 Telephone: (202) 289-6868 [email protected] [email protected] Sarah C. Tallman Natural Resources Defense Council 20 N. Wacker Dr., Ste. 1600 Chicago, IL 60606 Telephone: (312) 651-7918 [email protected] Counsel for Petitioner Natural Resources Defense Council, Inc. 2 IN THE UNITED STATES COURT OF APPEALS FOR THE DISTRICT OF COLUMBIA CIRCUIT NATURAL RESOURCES DEFENSE COUNCIL, INC., Petitioner, v. Case No. _______ ANDREW WHEELER, Administrator, U.S. Environmental Protection Agency, and UNITED STATES ENVIRONMENTAL PROTECTION AGENCY, Respondents.
    [Show full text]
  • Mergers, Acquisitions, Name Changes
    MERGERS, ACQUISITIONS, NAME CHANGES 575 Mergers, Acquisitions, Name Changes Looking for a manufacturing company that doesn’t seem to be listed in this 2009 Directory Issue? If you can’t find it in the Manufacturers Alphabetic Listings, then one of several things may have happened. The company could have dropped out of the hvacr industry — ceased to operate altogether, or just stopped making hvacr products; or the company may have changed owners and it is now a part of another corpo- rate identity. In either case, this listing may help. Following are the names of hundreds of manufacturers and their brand names that were found in previous editions of the Directory Issue. Many of these companies continue to exist, but are now known under different names. To find the new identity, just look up the old name in this alphabetic listing. If no information is available, we simply provide the last year the company was listed in the Directory Issue. This listing represents our best efforts at tracking the manufacturer-members of the hvacr community. If we have erred or provided incomplete information, we apologize and hope that you will set us straight. Contact The News Editorial Department at P.O. Box 2600, Troy, Mich. 48007. A Adelta Mfg Co., Inc., Philadelphia AAF-McQuay Inc., Dallas Last listed in 1971. As part of a corporate reorganization in 1994, SnyderGeneral Corp. was given this new name and Advance Systems Inc., Lewiston, Maine was divided into two major companies — McQuay The company was sold to Erie Manufacturing Co. International and AAF International.
    [Show full text]
  • Proposed Rule: Protection of Stratospheric Ozone
    The EPA Administrator, Gina McCarthy, signed the following proposed rule on October 15, 2015, and EPA is submitting it for publication in the Federal Register (FR). While we have taken steps to ensure the accuracy of this Internet version of the rule, it is not the official version of the rule for purposes of public comment. Please refer to the official version in a forthcoming FR publication, which will appear on the Government Printing Office's FDsys website (http://www.gpo.gov/fdsys/search/home.action) and on Regulations.gov (http://www.regulations.gov) in Docket No. EPA-HQ-OAR-2015-0453. Once the official version of this document is published in the FR, this version will be removed from the Internet and replaced with a link to the official version. This document is a prepublication version, signed by the EPA Administrator, Gina McCarthy, on October 15, 2015. We have taken steps to ensure the accuracy of this version, but it is not the official version. 6560-50-P ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 82 [EPA-HQ-OAR-2015-0453; FRL-9933-48-OAR] RIN: 2060-AS51 Protection of Stratospheric Ozone: Update to the Refrigerant Management Requirements under the Clean Air Act AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY: The Clean Air Act prohibits the knowing release of ozone-depleting and substitute refrigerants during the course of maintaining, servicing, repairing, or disposing of appliances or industrial process refrigeration. The existing regulations require that persons servicing or disposing of air-conditioning and refrigeration equipment observe certain service practices that reduce emissions of ozone-depleting refrigerant.
    [Show full text]
  • Geyser C-Series 2019
    Geyser C-Series 2019 The Nyle Systems Geyser C-Series product line is a High Efficiency Air-to-Water or Water-to Water Heat Pump Water Heating System. Heat Pump Water Heaters provide the most efficient way to heat water , drawing energy from the ambient air or available source water and thereby saving up to 75% in costs when compared to electric water heaters. Upon using the air source models, air surrounding the C-Series is cooled and dehumidified, which can be ducted to an alternate location, while heating potable water. In utilizing the water source models, we are cooling source water on one side while heating potable water on the other. We are reducing air conditioning load as well as reducing heating costs. The C-Series are designed and manufactured in our state How does the GEYSER C-Series work? of the art facility located in Brewer, Maine. These units use various options to meet your application needs. They are The Geyser Heat Pump Water Heater captures heat and suitable for drinking water applications with the standard humidity from the surrounding air, or heat from source double wall heat exchanger. water, and transfers that heat energy into a storage tank. In basic terms, Heat Pump Water Heaters move Energy Efficiency heat from where it is not needed, to where it is desired. Performance is expressed in Coefficient of Performance The Geyser C-Series provides low cost water heating (COP). In typical installations, the Geyser C-Series and supplemental cooling that can be directed where achieve COP’s ranging from 3-5.
    [Show full text]
  • The Economics of Reclamation
    VISITVISIT USUS ONON THETHE WEB!WEB! FindFind more more inspiring spotlights stories at at greenhvacrmag.comgreenhvacrmag.com Up Close Behind the Scenes with the Industry’s Leading Innovators The best replacement for R-22 is reclai m ed R-22, according to the experts at Hudson Technologies Co m p any. over Antarctica) and allowing harmful ultra- U.S. and most other developed countries in Rogers Supply Company in Illinois. She The process Zugibe developed a quar- violet radiation to reach humans and other 2020. So where does that leave owners of shares that the per-pound prices have ranged ter-century ago is fundamentally the same life back on the ground. legacy coolers, those designed to run with the from $5.50 in 2015 to $11 in 2016–2017, as what’s used today, and it’s still the fast- The phasing out of CFCs is widely cred- greatest energy efficiency on R-22? then back down to $7 in 2018. “Some people est, most efficient reclamation equipment ited as an effective global effort to repair the The economic and environmental equation worry that R-22 will run out in the future. in the world, able to reclaim every type of ozone hole. In place of CFCs came other is not lost on Hudson. The company’s tech- But we tell them if their equipment is in good refrigerant on the market. And with mil- technologies (HCFCs and HFCs), and in nologies and services—as delivered through shape to stick with the reclaimed product.” lions poured into further research and de- particular HCFC-22, otherwise referred to wholesalers and HVAC contractors—enable People like Lampton are on the front lines velopment, Hudson Technologies can also as R-22.
    [Show full text]
  • Freon™ 123 PUSH Bulletin
    Freon™ 123 Refrigerant (R-123) Properties, Uses, Storage, and Handling Freon™ 123 Refrigerant Table of Contents Shipping, Storage, and Handling ......................................16 Shipping Containers in the United States ..............................16 Introduction ...........................................................................3 Bulk Storage Systems ..........................................................................16 Background .......................................................................................................... 3 Storage, Handling, and Use Recommendations .................16 Freon™ 123—An Environmentally Acceptable Prohibited Uses ...................................................................................16 Alternative ....................................................................................................... 3 Personal Protective Equipment ................................................17 Uses .......................................................................................3 Storage ......................................................................................................17 Refrigerant ...................................................................................................... 4 Handling ....................................................................................................17 Heat-Transfer Fluid ....................................................................................4 Charging, Maintenance, and Sampling .................................18
    [Show full text]
  • HFC Proposed Second 15-Day Changes Notice
    State of California Air Resources Board Second Notice of Public Availability of Modified Text and Availability of Additional Documents Proposed Amendments to the Prohibitions on Use of Certain Hydrofluorocarbons in Stationary Refrigeration, Chillers, Aerosols-Propellants, and Foam End-Uses Regulation Public Hearing Date: December 10, 2020 Public Availability Date: August 3, 2021 Deadline for Public Comment: August 18, 2021 At its December 10, 2020, public hearing, the California Air Resources Board (CARB or Board) approved for adoption the proposed amendments to sections 95371, 95372, 95373, 95374, 95375, 95376, 95377, 95378, and added section 95379 Article 4, Subarticle 5, Chapter 1, Division 3, Title 17, California Code of Regulations, which prohibits certain substances in refrigeration, air-conditioning (AC), chillers, cold storage, aerosols-propellants, and foam end-uses to reduce high-global warming hydrofluorocarbon (HFC) emissions and support California’s greenhouse gas (GHG) emission reduction goals. In Resolution 20-37, the Board recognized the importance of near-term actions to reduce GHGs, including HFCs, by ensuring successful and orderly transition to lower global warming potential (GWP) refrigerants, which is necessary to reduce the impacts of climate change, and meet California’s legal mandate to reduce HFC emissions by 40 percent below 2013 levels by 2030, as identified in section 39730.5 of the Health and Safety Code. The Board, therefore, approved the adoption of the proposed amendments and found that an additional compliance pathway for AC manufacturers was appropriate.1 The Board directed the Executive Officer to determine if additional conforming modifications to the regulation were appropriate and to make any proposed modified regulatory language available for public comment, with any additional supporting 1 See State of California, Air Resources Board, Board Hearing Transcript, December 10, 2020.
    [Show full text]
  • Freon™ 407C and 407A Properties, Uses, Storage, and Handling
    Freon™ 407C and 407A Refrigerants (R-407C and R-407A) Properties, Uses, Storage, and Handling Freon™ Refrigerants Table of Contents Introduction ...........................................................................4 Air Monitors and Leak Detection ...................................... 16 Freon™ 407C and Freon™ 407A Refrigerant Types of Detectors .................................................................................16 Descriptions ................................................................................................... 4 Nonselective Detectors .................................................................16 Uses ......................................................................................4 Halogen-Selective Detectors ....................................................16 Physical Properties ...............................................................4 Compound-Specific Detectors .................................................16 Fluorescent Additives .....................................................................16 Chemical/Thermal Stability .............................................. 10 Stability with Metals .............................................................................10 Storage and Handling ........................................................ 17 Thermal Decomposition......................................................................11 Shipping Containers in the United States ..............................17 Compatibility Concerns If HCFC-22 and Freon™ Bulk Storage
    [Show full text]
  • Low Pressure Refrigerant Reclamation Systems
    http://www.siqinc.com/hvacr-manufacturing/refrigerant-reclamation/low-pressure-refrigerant-reclamation-systems/ PG 1 of 1 Low Pressure Refrigerant Reclamation Systems This system addresses the needs of commercial system manufacturers looking to reclaim the large volume, low pressure refrigerant charges from their chillers and roof top products. Our turnkey system initiates the process with an inlet tank to consolidate and convert refrigerant into vapor phase. Refrigerant then flows to the automatic processing station that removes particulates, oil, non condensible gasses and moisture. Refrigerant is processed to reclaimed quality specifications before being pumped to the storage tank for testing and re-use. The world’s largest chiller and commercial HVAC system manufacturers depend on this system to reclaim their low pressure refrigerant charges from repair areas, test areas, and laboratory units. Low Pressure Reclaimed Inlet Evaporator Tank Product Detail Refrigerant Holding Tank STANDARD FEATURES: PRODUCT OPTIONS: DIMENSIONS: • Automatic operation • Back-up compressor 74″H x 60”W x 72”D • Refrigerant reclamation to ARI-700 • Air cooled or water cooled condensing unit UTILITY REQUIREMENTS: • Pressure blower for compression of refrigerant • Process R-11, HCFO-1233ZD, or other Electric: 480V, 3Ø, 60A low pressure refrigerants • Oil separation and automatic drain Air: 100 psig shop air • Scalable for various recovery rates • High capacity desiccant driers Water: City water or chilled water supply • Reclaimed refrigerant moisture indicator (water-cooled systems only) • Automatic air/non-condensable removal • Onboard, electric transfer pump • Allen Bradley PLC control and Operator Interface • Warning light fault indicator • Panel mounted hour meter • Reclaimed refrigerant totalizing meter Serv-I-Quip, Inc.
    [Show full text]