Spc Benchmark 1™ Executive Summary Texas Memory Systems, Inc

Total Page:16

File Type:pdf, Size:1020Kb

Spc Benchmark 1™ Executive Summary Texas Memory Systems, Inc SPC BENCHMARK 1™ EXECUTIVE SUMMARY TEXAS MEMORY SYSTEMS,INC. TEXAS MEMORY SYSTEMS RAMSAN-630 SPC-1 V1.12 Submitted for Review: May 10, 2011 Submission Identifier: A00105 EXECUTIVE SUMMARY Page 2 of 7 EXECUTIVE SUMMARY Test Sponsor and Contact Information Test Sponsor and Contact Information Texas Memory Systems, Inc. – http://www.ramsan.com Test Sponsor Timothy Logan – [email protected] Primary Contact 10777 Westheimer, Ste. 600 Houston, TX 77042 Phone: (713) 266-3200 FAX: (713) 266-0332 Texas Memory Systems, Inc. – http://www.ramsan.com Test Sponsor Jamon Bowen – [email protected] Alternate Contact 10777 Westheimer, Ste. 600 Houston, TX 77042 Phone: (713) 266-3200 FAX: (713) 266-0332 Auditor Storage Performance Council – http://www.storageperformance.org Walter E. Baker – [email protected] 643 Bair Island Road, Suite 103 Redwood City, CA 94063 Phone: (650) 556-9384 FAX: (650) 556-9385 Revision Information and Key Dates Revision Information and Key Dates SPC-1 Specification revision number V1.12 SPC-1 Workload Generator revision number V2.1.0 Date Results were first used publicly May 10, 2011 Date the FDR was submitted to the SPC May 10, 2011 Date the priced storage configuration is available for currently available shipment to customers Date the TSC completed audit certification May 10, 2011 SPC BENCHMARK 1™ V1.12 EXECUTIVE SUMMARY Submission Identifier: A00105 Texas Memory Systems, Inc. Submitted for Review: MAY 10, 2011 Texas Memory Systems RamSan-630 EXECUTIVE SUMMARY Page 3 of 7 Tested Storage Product (TSP) Description The Texas Memory Systems’ RamSan-630 rack mounted SLC NAND Flash system is a 3U enterprise class designed solid state disk offering scalable performance and affordable high capacity. In addition it offers: x 1-10TB usable SLC NAND Flash storage capacity x ECC and RAID protection designed in at the chip level x Extremely low latency, providing both outstanding transaction and bandwidth performance x Fibre Channel or Infiniband connectivity The SPC-1 result demonstrates the latest performance ability of the Texas Memory Systems’ RamSan product line. This product is available for purchase today. Summary of Results SPC-1 Reported Data Tested Storage Product (TSP) Name: Texas Memory Systems RamSan-630 Metric Reported Result SPC-1 IOPS 400,503.26 SPC-1 Price-Performance $1.05/SPC-1 IOPS™ Total ASU Capacity 8,116.579 GB Data Protection Level Protected (RAID-5) Total TSC Price (including three-year maintenance) $419,292.00 SPC-1 IOPS™ represents the maximum I/O Request Throughput at the 100% load point. Total ASU (Application Storage Unit) Capacity represents the total storage capacity read and written in the course of executing the SPC-1 benchmark. A Data Protection Level of Protected using RAID-5. The Texas Memory Systems RamSan-630 uses a modified RAID-5 algorithm to ensure that the failure of a Flash memory chip does not result in data corruption. The modification to the RAID-5 makes an important leap forward over HDD-based RAID-5 write performance. On HDD RAID-5 implementations, any time even a small block of data is written, the RAID-5 controller must read back the entire data stripe and the parity bits, then rewrite the data, and finally rewrite the parity. But the RamSan-630 always writes to a new location on the Flash medium as part of its wear leveling algorithm, so a read of the old data and parity before a write is not required. SPC BENCHMARK 1™ V1.12 EXECUTIVE SUMMARY Submission Identifier: A00105 Texas Memory Systems, Inc. Submitted for Review: MAY 10, 2011 Texas Memory Systems RamSan-630 EXECUTIVE SUMMARY Page 4 of 7 Storage Capacities and Relationships The following diagram and table document the various storage capacities, used in this benchmark, and their relationships, as well as the storage utilization values required to be reported. Unused Storage – 2,191.28 GB Application Storage Unit (ASU) Capacity 2,061.647 GB Global StorageOverhead 8,116.579 GB ASU 1 ASU 2 ASU 3 Data Protection (RAID-5) 3,652.457 GB 3,652.457 GB 811.666 GB 1,374.390 GB 1 Logical Volume 1 Logical Volume 1 Logical Volume (includes 562.732 GB of Unused Storage) Addressable Storage Capacity 8,116.579 GB Configured Storage Capacity 9,490.969 GB Physical Storage Capacity 13,743.895 GB SPC-1 Storage Capacity Utilization Application Utilization 59.06% Protected Application Utilization 64.96% Unused Storage Ratio 20.04% Application Utilization: Total ASU Capacity (8,116.579 GB) divided by Physical Storage Capacity (8,116.579 GB) Protected Application Utilization: (Total ASU Capacity (8,116.579 GB) plus total Data Protection Capacity (1,374.390 GB) minus unused Data Protection Capacity (562.732 GB) divided by Physical Storage Capacity (8,116.579 GB) Unused Storage Ratio: Total Unused Capacity (2,754.011 GB) divided by Physical Storage Capacity (8,116.579 GB) and may not exceed 45%. Detailed information for the various storage capacities and utilizations is available on pages 19-20 in the Full Disclosure Report. SPC BENCHMARK 1™ V1.12 EXECUTIVE SUMMARY Submission Identifier: A00105 Texas Memory Systems, Inc. Submitted for Review: MAY 10, 2011 Texas Memory Systems RamSan-630 EXECUTIVE SUMMARY Page 5 of 7 Response Time – Throughput Curve The Response Time-Throughput Curve illustrates the Average Response Time (milliseconds) and I/O Request Throughput at 100%, 95%, 90%, 80%, 50%, and 10% of the workload level used to generate the SPC-1 IOPS™ metric. The Average Response Time measured at the any of the above load points cannot exceed 30 milliseconds or the benchmark measurement is invalid. Ramp Phase Response Time / Throughput Curve 30 25 20 15 Response Time (ms) 10 100% 5 95% 90% 80% 0 10% 50% 0 50000 100000 150000 200000 250000 300000 350000 400000 450000 IO Requests per Second Response Time – Throughput Data 10% Load 50% Load 80% Load 90% Load 95% Load 100% Load I/O Request Throughput 40,045.71 200,250.39 320,375.99 360,425.44 380,450.36 400,503.26 Average Response Time (ms): All ASUs 0.22 0.34 0.75 1.61 2.76 7.71 ASU-1 0.25 0.36 0.72 1.45 2.48 8.14 ASU-2 0.24 0.36 0.73 1.43 2.22 4.36 ASU-3 0.15 0.28 0.80 2.04 3.60 8.25 Reads 0.34 0.45 0.69 0.98 1.39 4.88 Writes 0.14 0.27 0.78 2.02 3.65 9.55 SPC BENCHMARK 1™ V1.12 EXECUTIVE SUMMARY Submission Identifier: A00105 Texas Memory Systems, Inc. Submitted for Review: MAY 10, 2011 Texas Memory Systems RamSan-630 EXECUTIVE SUMMARY Page 6 of 7 Priced Storage Configuration Pricing Ln# Qty Part Description UnitPrice ExtPrice HARDWARE 11UͲRS630/10 RamSanͲ630(10TB) $314,500.00 $314,500.00 21UͲ630ͲFCͲ381Ͳi IncludedFCInterface $0.00 $0.00 34UͲ630ͲFCͲ381 AdditionalFCInterface $4,000.00 $16,000.00 41UͲ630ͲSparesKitͲGM/500GBͲi IncludedSparesKitwith500GBFlash $0.00 $0.00 51UͲ630ͲRackSL RackSlideKit $200.00 $200.00 HardwareListPrice $330,700.00 HardwareDiscount 0% Ͳ HardwareSubͲTotal $330,700.00 Ln# Qty Part Description UnitPrice ExtPrice SUPPORT 61iͲWarrantyͲCritical CriticalWarranty $72,710.00 $72,710.00 SupportListPrice $72,710.00 SupportDiscount 0% Ͳ SupportSubͲTotal $72,710.00 Ln# Qty Part Description UnitPrice ExtPrice ThirdͲPartyComponents 8 10 QLE2562ͲCK QLogic8GbPCIex8FibreChannel2ͲportHBA $1,549.80 $15,498.00 9 10 J9281B TrippLitemultimodeduplexFibreChannelcableLC/LC2m $38.40 $384.00 ADDITIONALITEMSSUBͲTOTAL $15,882.00 TOTALPURCHASEPRICE $419,292.00 The above pricing includes hardware maintenance and software support for three years, 7 days per week, 24 hours per day. The hardware maintenance and software support provides the following: x Acknowledgement of new and existing problems with four (4) hours. x Onsite present of a qualified maintenance engineer or provision of a customer replaceable part within four (4) hours of the above acknowledgement for any hardware failure that results in an inoperative Price Storage Configuration that can be remedied by the repair or replacement of a Priced Storage Configuration component. Differences between the Tested Storage Configuration (TSC) and Priced Storage Configuration There were no differences between the TSC and the Priced Storage Configuration. SPC BENCHMARK 1™ V1.12 EXECUTIVE SUMMARY Submission Identifier: A00105 Texas Memory Systems, Inc. Submitted for Review: MAY 10, 2011 Texas Memory Systems RamSan-630 EXECUTIVE SUMMARY Page 7 of 7 Priced Storage Configuration Diagram Texas Memory Systems RamSan-630 20 – 640 GiB Solid State Devices (SSDs) 5 – dual-port FC-381 8Gb FC interfaces 10 – Qlogic QLE2562 8Gb FC HBAs Priced Storage Configuration Components Priced Storage Configuration Components: 10 – Qlogic QLE2562-CK 8Gb Fibre Channel HBAs Texas Memory System RamSan-630 5 – dual-port FC-381 8Gb Fibre Channel interfaces 10 – FC-381 8Gb Fibre Channel connections (10 used) 20 – 640 GiB Solid State Devices (SSDs) 10 – multimode duplex Fibre Channel LC/LC 2m cables 1 – U-630 Spares Kit with 500 GB Flash 1 – Rack Slide Kit SPC BENCHMARK 1™ V1.12 EXECUTIVE SUMMARY Submission Identifier: A00105 Texas Memory Systems, Inc. Submitted for Review: MAY 10, 2011 Texas Memory Systems RamSan-630 .
Recommended publications
  • Jim Handy Jim.Handy(At)Objective-Analysis.Com PO Box 440, Los Gatos, CA 95031-0440, USA +1 (408) 356-2549
    Jim Handy Jim.Handy(at)Objective-Analysis.com PO Box 440, Los Gatos, CA 95031-0440, USA +1 (408) 356-2549 Experience Experienced in Trial & Deposition Testimony, Expert Reports, etc. Highly published and widely quoted as a key semiconductor industry analyst. 37-year semiconductor industry veteran. Honorary Member: Storage Networking Industry Association (SNIA) Deep technical understanding and design background. Highly analytical. Excellent communications skills: oral, written, and presentation. Author of key reference design work: “The Cache Memory Book” Harcourt Brace, 1993 Patent holder in cache memory design Expert Experience Trial Testimony In Re: Spansion et al Federal Bankruptcy Court of Delaware Docket No: 09-10690, (Hon. Kenneth Carey). 11/30/09 Netlist, Inc. (Plaintiff) vs. Diablo Technologies, Inc. (Defendant), US District Court, Northern District of CA, Case No. 13-CV-05962 YGR, (Hon. Yvonne Gonzalez Rogers), 3/13/15 Deposition Testimony In Re: Spansion et al Federal Bankruptcy Court of Delaware Docket No: 09-10690, (Hon. Kenneth Carey). 11/24/09 In Re: SRAM, 07-CV-1819-CW (N.D. Cal.), 3/25/10 Expert Reports Expert Rebuttal Report - In Re: Spansion et al Federal Bankruptcy Court of Delaware Docket No: 09-10690, (Hon. Kenneth Carey). 11/20/09 (8 pages) Expert Report - In Re: SRAM, 07-CV-1819-CW (N.D. Cal.), 1/25/10 (13 pages) Expert Report - In Re: Qimonda Richmond, LLC, et al., Case No. 09-10589 (MFW) 2/6/12 (30 pages) Expert Report - Netlist, Inc. (Plaintiff) vs. Diablo Technologies, Inc. (Defendant), US District Court, Northern District of CA, Case No. 13-CV-05962 YGR, (Hon.
    [Show full text]
  • IDC Vendor Profile Of
    VENDOR PROFILE SVP.11: Texas Memory Systems Delivering on the SSD Promise Jeff Janukowicz IDC OPINION The solid state drive (SSD) market is full of activity, with companies large and small announcing products that carry a promise of impressive performance gains, low power consumption, and cost-effective solutions when compared with the 50-year-old mechanical hard disk drive (HDD). Yet, for one company, Texas Memory Systems (TMS), with over 30 years of experience and 15 generations of SSD products, delivering on the promise of SSDs is nothing new. For some companies, they are just entering the SSD market by announcing their intentions or partners and realizing revenue is still a future event. TMS, on the other hand, is growing its RamSan SSD business with sales to end users through OEM, reseller, and direct channels and has positioned itself well within what IDC believes is a fast-growing market. TMS specializes in providing low-latency, high-bandwidth, I/O-intensive storage systems. TMS strengths include: Solid engineering focus. SSDs are advanced storage solutions that require both innovation and detailed knowledge to integrate solid state memory, memory management, controllers, and backplanes into a storage system without sacrificing performance. TMS does most of its engineering internally. Over 50% of its employees are engineers with an average of 5+ years of software experience and 10+ years of hardware experience at TMS designing SSD solutions for enterprise customers. This level of technical expertise is vital to deliver on the promise of SSDs, to iterate products rapidly in a competitive marketplace and, perhaps most important, to support enterprise customers.
    [Show full text]
  • Your Guide to All-Flash Storage, How It Stacks up Against Hybrid and Pcie, and How to Measure the Benefits
    All-Flash: The Essential Guide All-Flash: The Essential Guide Your guide to all-flash storage, how it stacks up against hybrid and PCIe, and how to measure the benefits All-Flash: The Essential Guide In this e-guide In this e-guide: All-flash array roundup 2016: Computer Weekly keeps its finger on the pulse in the world of The big six data storage, with regular news, features and practical articles. This guide offers a comprehensive survey of the all- All-flash storage roundup flash array market. We look at all-flash products from the big 2016: The startups six storage vendors and the startups and specialists. Plus, we give the lowdown on all-flash vs hybrid flash arrays and all- Hybrid flash vs all-flash storage: When is some flash flash vs server-side PCIe SSD. Finally, we look at the not enough? shortcomings of measuring the value of flash by metrics designed for spinning disk and suggest practical alternatives. PCIe SSD vs all-flash for enterprise storage How to measure flash storage's true value Antony Adshead, Storage editor Page 1 of 32 All-Flash: The Essential Guide In this e-guide All-flash array roundup 2016: The big six All-flash array roundup 2016: Chris Evans, Contributor The big six In all-flash storage 2015 was year of consolidation, incremental improvement All-flash storage roundup and price reduction from the big six storage suppliers. 2016: The startups In a short space of time, the big six storage providers have built out their flash product offerings into mature and scalable platforms.
    [Show full text]
  • V-Series Implementation Guide Ramsan Storage
    V-Series Systems Implementation Guide for RamSan Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Documentation comments: [email protected] Information Web: http://www.netapp.com Part number: 210-04513_A0 July 2009 Copyright and trademark information Copyright Copyright © 1994-2009 NetApp, Inc. All rights reserved. Printed in the U.S.A. information Software derived from copyrighted NetApp material is subject to the following license and disclaimer: THIS SOFTWARE IS PROVIDED BY NETAPP “AS IS” AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp.
    [Show full text]
  • Texas Memory Systems Ramsan-620 Data Sheet
    Preliminary RAM-SAN™ 5-TB The World's Fastest Storage ® RamSan-620 Flash 1-5 TB Flash Storage 3 Gigabytes per Second 250,000 IOPS 2-8 FC Links (4Gb) RamSan-620 Very Fast Solid State Disk (SSD) Automatic Error Checking The RamSan-620 storage system is the World's Fastest Storage data integrity is provided by the use of SLC Flash Storage system. With a capacity of 5-TB, Flash chips with two independent methods of ECC. 3-GB/sec bandwidth, and 250,000 IOPS, the Each Flash chip incorporates an ECC data field within RamSan-620 sets the bar for Enterprise Flash storage. the chip for initial checking. Additionally, each set of Reliability and system management is very important. flash chips is organized as a board-level RAID; The RamSan-620 incorporates 2 Error Correcting thereby eliminating any single chip failure from Circuits (ECC) and has the many standard corrupting data. At the system-level, a board can be management features inherent in all RamSan storage designated an Active Spare. In the event of a Flash systems. As is the case with all previous RamSan chip failure, Active Spare migrates the data from the systems, the RamSan-620 is easy to install. flash card with a degraded RAID onto the designated Active Spare to return to fully redundant state without Features the need for unscheduled maintenance. The RamSan-620 has the features you expect: ! A Complete Flash storage system in a 2U rack Applications for the RamSan-620 ! Low Overhead, Low Power, High Performance Databases Hot Files ! High IOPS, Bandwidth, Capacity ! Standard Management
    [Show full text]
  • Validating You IO Subsystem
    Validating your IO Subsystem Coming Out of the Black Box Mike Ault, Oracle Guru, TMS, Inc. A Texas Memory Systems Presentation The Black Box For most people the IO subsystem for their servers is a black box. The capacity (as defined in megabytes) is easy to confirm The performance (defined by input and output operations per second (IOPS) and latency (milliseconds, ms) may be more difficult to determine. In this paper we will explore different methodologies to obtain the IOPS and latency for your application. A Texas Memory Systems Presentation IO Is not a Black Box We are led to believe that the entire IO subsystem is out of our hands The details of the IO subsystem will make or break your database performance. Eventually almost all performance issues are traced to IO issues. A Texas Memory Systems Presentation IO is Not a Black Box Inside Oracle, views such as v$filestat and v$tempstat provide cumulative information about IO operations Using some simple queries you can determine long term averages for IOPS and latency for the files in your system. To get more granular data, tools such as Statspack and AWR must be used A Texas Memory Systems Presentation Example IO Script column sum_io1 new_value st1 noprint column sum_io2 new_value st2 noprint column sum_io new_value divide_by noprint rem select nvl(sum(a.phyrds+a.phywrts),0) sum_io1 from sys.v_$filestat a; select nvl(sum(b.phyrds+b.phywrts),0) sum_io2 from sys.v_$tempstat b; select &st1+&st2 sum_io from dual; rem ttitle 'File IO Statistics Report' spool fileio A Texas Memory
    [Show full text]
  • Enterprise Flash Array Storage
    EFA Enterprise Flash Array Storage A Peek Into What Real Users Think December 2016 Enterprise Flash Array Storage Contents Vendor Directory 3 Top 10 Vendors 4 - 5 Top 5 Solutions by Ranking Factor 6 Focus on Solutions HPE 3PAR Flash Storage 7 - 9 Tintri VMstore 10 - 12 NetApp All Flash FAS 13 - 15 Pure Storage 16 - 18 Nimble Storage 19 - 21 EMC VNX 22 - 24 Kaminario K2 25 - 27 SolidFire 28 - 30 IBM FlashSystem 31 - 32 NetApp EF-Series All Flash Arrays 33 - 35 About This Report and IT Central Station 36 2 Enterprise Flash Array Storage Vendor Directory Dell EMC Dell EMC XtremIO Flash Storage NetApp SolidFire Dell EMC EMC VNX NetApp NetApp EF-Series All Flash Arrays Dell EMC EMC Unity NexGen Storage NexGen Storage Dell EMC EMC DSSD D5 Nimble Storage Nimble Storage E8 Storage E8 Storage Nimbus Data Nimbus Data Gemini All-Flash Arrays Elastifile Elastifile Oracle Oracle FS1 Flash Storage System Hewlett Packard HPE 3PAR Flash Storage Pure Storage Pure Storage Enterprise Reduxio Reduxio Hitachi Hitachi Virtual Storage Platform SanDisk SanDisk InfiniFlash System Hitachi Hitachi Universal Storage VM SanDisk Fusion-io IBM IBM FlashSystem Tegile Tegile IBM IBM Storwize Tintri Tintri VMstore Kaminario Kaminario K2 Violin Memory Violin Memory NetApp NetApp All Flash FAS © 2016 IT Central Station To read more reviews about Enterprise Flash Array Storage, please visit: http://www.itcentralstation.com/category/enterprise-flash-array-storage 3 Enterprise Flash Array Storage Top Enterprise Flash Array Storage Solutions Over 127,030 professionals have used IT Central Station research on enterprise tech. Here are the top Enterprise Flash Array Storage vendors based on product reviews, ratings, and comparisons.
    [Show full text]
  • Essential Guide to Solid-State Drives
    Managing the information that drives the enterprise STORAGE ESSENTIAL GUIDE TO Solid-State Drives Solid-state drive technologies that will have the most impact for enterprise data storage administrators are highlighted in this guide. INSIDE 6 SSD trends 13 Wide stripe before you dive into SSD 16 DRAM SSD leaves FC in the dust 18 MLC NAND flash 22 When to recommend SSD 27 Vendor resources 1 , editorial | rich castagna s e c r u o s e r r The state of storage o d n e Solid-state storage is poised to revolutionize V data center storage with new and inventive implementations of NAND flash already available. D S S g n i d n e T’S SMALL, it runs cool, it’s power efficient and it’s lightning fast. There’s m an awful lot to like about solid-state storage. Put it head-to-head with m o traditional spinning media and it wins on nearly all counts, with admit- c e tedly some not yet fully resolved issues related to long-term reliability R and price. Still, few would question that solid-state is the direction that enterprise storage is headed. The real question is just how soon the transition from mechanical storage to solid The real question is state will take place. D just how soon the S Although new to the data center, NAND S i flash-based solid-state storage has been transition from M A around for a long time, used mostly in R mechanical storage D consumer and mobile products like smart phones, PDAs and MP3 players.
    [Show full text]
  • SSD Industry Report 2010
    Rise of SSD in the Enterprise SSD Industry Report 2010 TABLE OF CONTENTS 1 Executive Summary 1.1 Executive Overview 1.2 Storage Industry Dynamics Computing Landscape – 1980 vs 2010 Closing the Price/Performance Gap in the Storage Hierarchy Access Density: A Growing Problem Memory Market Drivers 1.3 Market Status & Trends Solid State Drives: Market Drivers SSDs: When, Why and Where in the Computer Hierarchy? SSD Today & Challenges New SSD Market Segments – DRAM/SSD NVM vs. HDD/SSD Cache 1.4 Storage Market Segments & Product Requirements Application Driven Enterprise Requirements SSDs vs. HDDs: Features/Benefits, Competitive Pricing Pricing Dynamics – Impact on SSD Market Demand Price Driven SSD Market Demand Crossing over HDDs 1.5 Managing SSDs Controllers managing BER, Endurance, LifeCycles, Wear … Emphasizing Total Cost of Ownership 1.6 Enterprise SSD Price Forecast The Impact of Price Reductions SSD Costs Scale Out Model vs. Scale Up Models 1.7 Current Drivers & Inhibitors of SSD Why SSD Acceptance is still limited 1.8 Emerging Technologies MLC NAND, Phase Change 1.9 Futures SSD Industry Roadmap 2010-2020 2 Market Drivers & Industry Dynamics 2.1 Customers requirements for NextGen Storage 2.2 SSDs: A shift in Data Storage 2.3 Killer Applications & Infrastructure for SSDs 2.4 SSD Myths & Facts 2.5 SSD vs HDD Complexity of HDDs vs. Simplicity of SSDs Real TCO - Leveraging SSD’s advantage over HDDs SAN TCO Savings using Intelligent Tiered Storage Price & Capacity 2010 SSD vs. HDD Side/Side Comparison: Power Consumption, Performance, Total
    [Show full text]
  • Open Youngjaekim-Dissertation.Pdf
    The Pennsylvania State University The Graduate School DESIGN CHALLENGES ON ENTERPRISE-SCALE STORAGE SYSTEMS EMPLOYING HARD DRIVES AND NAND FLASH BASED SOLID-STATE DRIVES A Dissertation in Computer Science and Engineering by Youngjae Kim c 2009 Youngjae Kim Submitted in Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy December 2009 The dissertation of Youngjae Kim was reviewed and approved∗ by the following: Anand Sivasubramaniam Professor of Computer Science and Engineering Dissertation Co-Advisor, Co-Chair of Committee Bhuvan Urgaonkar Assistant Professor of Computer Science and Engineering Dissertation Co-Advisor, Co-Chair of Committee Prasenjit Mitra Assistant Professor of Computer Science and Engineering Qian Wang Associate Professor of Mechanical and Nuclear Engineering Raj Acharya Professor of Computer Science and Engineering Head of the Department of Computer Science and Engineering ∗Signatures are on file in the Graduate School. Abstract Flash memory overcomes some key shortcomings of hard disk drives (HDDs), in- cluding faster access to non-sequential data and lower power consumption. Eco- nomic forces, driven by the desire to introduce flash into the enterprise market without changing existing software based, have resulted in the emergence of solid- state drives (SSDs), flash packaged in HDD from factors and capable of working with device drivers and I/O buses designed for HDDs. Unlike the use of DRAM for caching or buffering, however, certain idiosyncrasies of SSDs make their inte- gration into HDD-based systems non-trivial. Flash memory suffers from limits on its reliability, in an order of magnitude more expensive than the disk, and can be sometimes even slower than the HDD (due to excessive GC induced by high intensity of random writes).
    [Show full text]
  • Flash Or SSD: Why and When to Use IBM Flashsystem
    Redpaper Megan Gilge Karen Orlando Flash or SSD: Why and When to Use IBM FlashSystem Overview This IBM® Redpaper™ publication explains how to select an IBM FlashSystem™ or solid-state drive (SSD) solution. It describes why and when to use FlashSystem products, and reviews total cost of ownership (TCO), economics, performance, scalability, power, and cooling. Read this guide for information about selecting the correct solution (SSD or flash technology). This paper also reviews examples of FlashSystem storage bundled with solutions such as hybrid arrays and IBM System Storage® SAN Volume Controller (SVC). Furthermore, it compares FlashSystem storage to other storage such as PCIe Express (PCIe) products and hard disk drives (HDDs). Business value of FlashSystem products FlashSystem storage systems deliver high performance, efficiency, and reliability for shared enterprise storage environments, which can help you address performance issues with your most important applications and infrastructure. FlashSystem products also provide capability for big data and cloud environments. These storage systems can either complement or replace traditional hard disk arrays in many business-critical applications: Online transaction processing (OLTP) Business intelligence (BI) Online analytical processing (OLAP) Virtual desktop infrastructures (VDI) High-performance computing (HPC) Content delivery solutions (such as cloud storage and video-on-demand) As standard shared primary data storage devices, FlashSystem storage delivers performance exponentially beyond that of most traditional arrays, even those arrays that incorporate SSDs or other flash technology. These storage systems can also be used as the top tier of storage © Copyright IBM Corp. 2013. All rights reserved. ibm.com/redbooks 1 alongside traditional arrays in tiered storage architectures such as the IBM Easy Tier® functionality available in the System Storage SVC storage virtualization platform.
    [Show full text]
  • Enterprise Use Cases for Solid State Storage/Flash Memory
    Outlook Report Enterprise Use Cases for Solid State Storage/Flash Memory An Outlook Report from Storage Strategies NOW September 17, 2013 By Deni Connor and James E. Bagley Client Relations: Phylis Bockelman Storage Strategies NOW 8815 Mountain Path Circle Austin, Texas 78759 (512) 345-3850 SSG-NOW.COM Note: The information and recommendations made by Storage Strategies NOW, Inc. are based upon public information and sources and may also include personal opinions both of Storage Strategies NOW and others, all of which we believe are accurate and reliable. As market conditions change however and not within our control, the information and recommendations are made without warranty of any kind. All product names used and mentioned herein are the trademarks of their respective owners. Storage Strategies NOW, Inc. assumes no responsibility or liability for any damages whatsoever (including incidental, consequential or otherwise), caused by your use of, or reliance upon, the information and recommendations presented herein, nor for any inadvertent errors which may appear in this document. This report is purchased by Dell, Inc., who understands and agrees that the report is furnished solely for distribution to prospects and customers. All Web distribution rights granted. Copyright 2013. All rights reserved. Storage Strategies NOW, Inc. Sponsor Dear Reader, SSG-NOW takes a look at technologies and products when confusion exists in a specific market. What is solid state storage or Flash Memory? How is it used best? What are the use cases for SSDs/Flash technologies? When should you adopt SSDs/Flash and how? This report will hopefully answer those questions about solid state/Flash-based storage and in what situations it is best used.
    [Show full text]