Solid State Storage for the Enterprise Woody Hutsell, Texas Memory Systems, Inc
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Fusion-Io Virtualization Reference Architecture
A Principled Technologies reference architecture commissioned by Fusion-io, Inc. (Revised) TABLE OF CONTENTS Table of contents ..................................................................................... 2 Executive summary .................................................................................. 3 Solution considerations ............................................................................ 4 Summary of main findings ........................................................................ 5 Solution components ............................................................................... 5 Cisco UCS ............................................................................................5 VMware vSphere 5.1 ..........................................................................6 VMware Horizon View ........................................................................6 Fusion ioControl Hybrid Storage Appliance ........................................7 Cisco UCS Fusion ioDrive2 785GB adapter and Fusion ioTurbine software ..............................................................................................9 Workloads ............................................................................................. 11 Login VSI workload .......................................................................... 11 OLTP (DVD Store) workload description .......................................... 12 Exchange (Microsoft LoadGen) ........................................................ 13 Solution architecture -
Jim Handy Jim.Handy(At)Objective-Analysis.Com PO Box 440, Los Gatos, CA 95031-0440, USA +1 (408) 356-2549
Jim Handy Jim.Handy(at)Objective-Analysis.com PO Box 440, Los Gatos, CA 95031-0440, USA +1 (408) 356-2549 Experience Experienced in Trial & Deposition Testimony, Expert Reports, etc. Highly published and widely quoted as a key semiconductor industry analyst. 37-year semiconductor industry veteran. Honorary Member: Storage Networking Industry Association (SNIA) Deep technical understanding and design background. Highly analytical. Excellent communications skills: oral, written, and presentation. Author of key reference design work: “The Cache Memory Book” Harcourt Brace, 1993 Patent holder in cache memory design Expert Experience Trial Testimony In Re: Spansion et al Federal Bankruptcy Court of Delaware Docket No: 09-10690, (Hon. Kenneth Carey). 11/30/09 Netlist, Inc. (Plaintiff) vs. Diablo Technologies, Inc. (Defendant), US District Court, Northern District of CA, Case No. 13-CV-05962 YGR, (Hon. Yvonne Gonzalez Rogers), 3/13/15 Deposition Testimony In Re: Spansion et al Federal Bankruptcy Court of Delaware Docket No: 09-10690, (Hon. Kenneth Carey). 11/24/09 In Re: SRAM, 07-CV-1819-CW (N.D. Cal.), 3/25/10 Expert Reports Expert Rebuttal Report - In Re: Spansion et al Federal Bankruptcy Court of Delaware Docket No: 09-10690, (Hon. Kenneth Carey). 11/20/09 (8 pages) Expert Report - In Re: SRAM, 07-CV-1819-CW (N.D. Cal.), 1/25/10 (13 pages) Expert Report - In Re: Qimonda Richmond, LLC, et al., Case No. 09-10589 (MFW) 2/6/12 (30 pages) Expert Report - Netlist, Inc. (Plaintiff) vs. Diablo Technologies, Inc. (Defendant), US District Court, Northern District of CA, Case No. 13-CV-05962 YGR, (Hon. -
Intel® Solid State Drive 730 Series Product Brief
PRODUCT BRIEF Intel® Solid State Drive 730 Series Data Center DNA Performance Unleashed Factory overclocked 3rd generation Intel controller infused with DNA stolen from the Intel SSD Data Center Family. Optimized for Performance 730 Series + Intel® Rapid Maximize your computing experience Storage Technology = Amazing with the Intel® Solid State Drive (Intel® Performance SSD) 730 Series, built with a specially Digital Content Creation experts and qualified 3rd generation Intel con- PC Enthusiasts know the highest troller, 20nm NAND and optimized storage performance is achieved firmware. with RAID-0 configurations as SSDs Intel has taken storage a step fur- saturate the SATA interface. Comparing ther by factory overclocking these two Intel SSD 730 Series drives in a components to push the limits of RAID-0 array to a single alternative performance with a 50% increase in SSD, results in the same capacity controller speed and 20% increase in and nearly double the performance. NAND bus speed. Intel SSD 730 Series As shown below, two Intel SSD 730 are optimized for the most demanding Series drives in a RAID-0 configuration tasks including digital content creation, can provide throughput numbers video capture/editing, extreme gaming exceeding 1000MB/s when coupled and other client usages where stor- with Intel platforms supporting Intel age performance improves the user’s Rapid Storage Technology (Intel® RST). experience and efficiency. Applications Similarly four Intel SSD 730 Series will benefit from the 50µs read latency, drives in a RAID-0 array with an Intel® up to 550MB/s sequential reads and chipset based platform can provide 89,000 IOPs random reads. -
Ulltradimm™ SSD Overview
ULLtraDIMM™ SSD Overview Rob Callaghan June 9th, 2014 c 1 A Global Leader in Flash Storage Solutions Rankings Trailing 4 Qtr Financials* Global Operations Leading Retail Brand° $6.2B Revenue #1 Global Retail $3.6B Net Cash* Revenue $0.7B R&D Investment 5,500 Employees† Share SanDisk Client All Leading & Retail SSDs Smartphone Approved & Tablet Supplier to Qualified at Manufacturers All Leading PC 6 of the Top 7 use SanDisk Manufacturers Server & Storage OEMs Enterprise SSDs and Storage Software *Financials as of Q4, ‘13. Net Cash = [Cash + cash equivalents + short-term & long-term marketable securities] less [debt at maturity value] as of the end of Q4, ‘13. †Headcount as of Jan., ‘14. NPD Estimate, Nov., ‘13. Estimates of the memory card & USB markets from NPD (Nov. ‘13) and GfK Retail and Technology, Sep., ‘13. 2 Enabling Flash Storage from Wafer to Software NAND TECH NAND DIE SCALE ASSY, TEST & CONTROLLER FLASH MGMT SSD SOFTWARE PACKAGING Close to Half of Industry Bit Output World-Leading Innovator + Together with manufacturing 4,900 Patents partner Toshiba Fabs: World class NAND capacity 1991 2013 Patents as of Oct., ‘13; NPD Estimate, Nov., ‘13. Gartner: NAND Flash Supply & Demand, WW 1Q ‘12-4Q ‘14, 3Q ’13. Update Dec., ‘13. 3 The Path to Ultra Low Latency & Scalable Performance DDR 1’s 10’s PCIe 100’s Latency (µsec) speed memory bus speed memory 1000’s on high the Flash Storage SAS/SATA/FC 1,000,000 100 100,000 IOPS 4 Creating a New Storage Interface This is a This is DRAM with SATA DIMM battery backup Flash Flash Flash Flash Flash -
The Benefits of Serial Attached SCSI (SAS) for External Subsystems
SERVER STORAGE SOLUTIONS WHITE PAPER The Benefits of Serial Attached SCSI (SAS) for External Subsystems Serial Attached SCSI (SAS), the follow-on to parallel The first SAS prototypes were announced in 2003 and SCSI, is designed for high-performance enterprise were a major step to achieving mass market requirements and offers both the benefits of backward availability. Those prototypes allowed development of compatibility with SCSI and interoperability with the first generation of technologies and products that Serial ATA (SATA), bringing enterprises a flexibility bring the benefits of SAS into the enterprise. These and cost savings previously not possible. SAS provides products have been developed and tested, and enable a significant benefits to external storage subsystems and wide variety of integrated solutions. offers users “one-stop-shopping” to satisfy their Interoperability testing was a key component of SAS, requirements for the following three main data types; because it increases the architecture’s flexibility by Throughput Data Transaction Data Reference Data supporting both SAS and SATA disk drives and components. Interoperability allows one vendor’s SAS • High MB/s and large • Maximum IOPs for OLTP, • Fixed content, archival data data-intensive files calculation intensive files for secondary/nearline products to be compatible with another’s, and it also • Large block, random • Small block, random storage ensures products developed today will work with all read/writes read/writes • Large block, sequential existing and next-generation -
IDC Vendor Profile Of
VENDOR PROFILE SVP.11: Texas Memory Systems Delivering on the SSD Promise Jeff Janukowicz IDC OPINION The solid state drive (SSD) market is full of activity, with companies large and small announcing products that carry a promise of impressive performance gains, low power consumption, and cost-effective solutions when compared with the 50-year-old mechanical hard disk drive (HDD). Yet, for one company, Texas Memory Systems (TMS), with over 30 years of experience and 15 generations of SSD products, delivering on the promise of SSDs is nothing new. For some companies, they are just entering the SSD market by announcing their intentions or partners and realizing revenue is still a future event. TMS, on the other hand, is growing its RamSan SSD business with sales to end users through OEM, reseller, and direct channels and has positioned itself well within what IDC believes is a fast-growing market. TMS specializes in providing low-latency, high-bandwidth, I/O-intensive storage systems. TMS strengths include: Solid engineering focus. SSDs are advanced storage solutions that require both innovation and detailed knowledge to integrate solid state memory, memory management, controllers, and backplanes into a storage system without sacrificing performance. TMS does most of its engineering internally. Over 50% of its employees are engineers with an average of 5+ years of software experience and 10+ years of hardware experience at TMS designing SSD solutions for enterprise customers. This level of technical expertise is vital to deliver on the promise of SSDs, to iterate products rapidly in a competitive marketplace and, perhaps most important, to support enterprise customers. -
Samsung V-NAND SSD 970 EVO
Data Sheet SAMSUNG PROPRIETARY Samsung V-NAND SSD 970 EVO 2018 Data Sheet )Revision 1.0 Add Title (SamsungOne300, 10pt) Revision 1.0 1 Data Sheet SAMSUNG PROPRIETARY DISCLAIMER SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE. Products and specifications discussed herein are for reference purposes only. All information discussed herein may change without notice and is provided on an “AS IS” basis, without warranties of any kind. This document and all information discussed herein remain the sole and exclusive property of Samsung Electronics. No license of any patent, copyright, mask work, trademark or any other intellectual property right is granted by one party to the other party under this document, by implication, estoppels or otherwise. Samsung products are not intended for use in life support, critical care, medical, safety equipment, or similar applications where product failure could result in loss of life or personal or physical harm, or any military or defense application, or any governmental procurement to which special terms or provisions may apply. For updates or additional information about Samsung products, contact your nearest Samsung office. COPYRIGHT © 2018 This material is copyrighted by Samsung Electronics. Any unauthorized reproductions, use or disclosure of this material, or any part thereof, is strictly prohibited and is a violation under copyright law. TRADEMARKS & SERVICE MARKS The Samsung Logo is the trademark of Samsung Electronics. Adobe is a trademark and Adobe Acrobat is a registered trademark of Adobe Systems Incorporated. All other company and product names may be trademarks of the respective companies with which they are associated. -
Your Guide to All-Flash Storage, How It Stacks up Against Hybrid and Pcie, and How to Measure the Benefits
All-Flash: The Essential Guide All-Flash: The Essential Guide Your guide to all-flash storage, how it stacks up against hybrid and PCIe, and how to measure the benefits All-Flash: The Essential Guide In this e-guide In this e-guide: All-flash array roundup 2016: Computer Weekly keeps its finger on the pulse in the world of The big six data storage, with regular news, features and practical articles. This guide offers a comprehensive survey of the all- All-flash storage roundup flash array market. We look at all-flash products from the big 2016: The startups six storage vendors and the startups and specialists. Plus, we give the lowdown on all-flash vs hybrid flash arrays and all- Hybrid flash vs all-flash storage: When is some flash flash vs server-side PCIe SSD. Finally, we look at the not enough? shortcomings of measuring the value of flash by metrics designed for spinning disk and suggest practical alternatives. PCIe SSD vs all-flash for enterprise storage How to measure flash storage's true value Antony Adshead, Storage editor Page 1 of 32 All-Flash: The Essential Guide In this e-guide All-flash array roundup 2016: The big six All-flash array roundup 2016: Chris Evans, Contributor The big six In all-flash storage 2015 was year of consolidation, incremental improvement All-flash storage roundup and price reduction from the big six storage suppliers. 2016: The startups In a short space of time, the big six storage providers have built out their flash product offerings into mature and scalable platforms. -
V-Series Implementation Guide Ramsan Storage
V-Series Systems Implementation Guide for RamSan Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Documentation comments: [email protected] Information Web: http://www.netapp.com Part number: 210-04513_A0 July 2009 Copyright and trademark information Copyright Copyright © 1994-2009 NetApp, Inc. All rights reserved. Printed in the U.S.A. information Software derived from copyrighted NetApp material is subject to the following license and disclaimer: THIS SOFTWARE IS PROVIDED BY NETAPP “AS IS” AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp. -
Spc Benchmark 1™ Executive Summary Texas Memory Systems, Inc
SPC BENCHMARK 1™ EXECUTIVE SUMMARY TEXAS MEMORY SYSTEMS,INC. TEXAS MEMORY SYSTEMS RAMSAN-630 SPC-1 V1.12 Submitted for Review: May 10, 2011 Submission Identifier: A00105 EXECUTIVE SUMMARY Page 2 of 7 EXECUTIVE SUMMARY Test Sponsor and Contact Information Test Sponsor and Contact Information Texas Memory Systems, Inc. – http://www.ramsan.com Test Sponsor Timothy Logan – [email protected] Primary Contact 10777 Westheimer, Ste. 600 Houston, TX 77042 Phone: (713) 266-3200 FAX: (713) 266-0332 Texas Memory Systems, Inc. – http://www.ramsan.com Test Sponsor Jamon Bowen – [email protected] Alternate Contact 10777 Westheimer, Ste. 600 Houston, TX 77042 Phone: (713) 266-3200 FAX: (713) 266-0332 Auditor Storage Performance Council – http://www.storageperformance.org Walter E. Baker – [email protected] 643 Bair Island Road, Suite 103 Redwood City, CA 94063 Phone: (650) 556-9384 FAX: (650) 556-9385 Revision Information and Key Dates Revision Information and Key Dates SPC-1 Specification revision number V1.12 SPC-1 Workload Generator revision number V2.1.0 Date Results were first used publicly May 10, 2011 Date the FDR was submitted to the SPC May 10, 2011 Date the priced storage configuration is available for currently available shipment to customers Date the TSC completed audit certification May 10, 2011 SPC BENCHMARK 1™ V1.12 EXECUTIVE SUMMARY Submission Identifier: A00105 Texas Memory Systems, Inc. Submitted for Review: MAY 10, 2011 Texas Memory Systems RamSan-630 EXECUTIVE SUMMARY Page 3 of 7 Tested Storage Product (TSP) Description The Texas Memory Systems’ RamSan-630 rack mounted SLC NAND Flash system is a 3U enterprise class designed solid state disk offering scalable performance and affordable high capacity. -
Texas Memory Systems Ramsan-620 Data Sheet
Preliminary RAM-SAN™ 5-TB The World's Fastest Storage ® RamSan-620 Flash 1-5 TB Flash Storage 3 Gigabytes per Second 250,000 IOPS 2-8 FC Links (4Gb) RamSan-620 Very Fast Solid State Disk (SSD) Automatic Error Checking The RamSan-620 storage system is the World's Fastest Storage data integrity is provided by the use of SLC Flash Storage system. With a capacity of 5-TB, Flash chips with two independent methods of ECC. 3-GB/sec bandwidth, and 250,000 IOPS, the Each Flash chip incorporates an ECC data field within RamSan-620 sets the bar for Enterprise Flash storage. the chip for initial checking. Additionally, each set of Reliability and system management is very important. flash chips is organized as a board-level RAID; The RamSan-620 incorporates 2 Error Correcting thereby eliminating any single chip failure from Circuits (ECC) and has the many standard corrupting data. At the system-level, a board can be management features inherent in all RamSan storage designated an Active Spare. In the event of a Flash systems. As is the case with all previous RamSan chip failure, Active Spare migrates the data from the systems, the RamSan-620 is easy to install. flash card with a degraded RAID onto the designated Active Spare to return to fully redundant state without Features the need for unscheduled maintenance. The RamSan-620 has the features you expect: ! A Complete Flash storage system in a 2U rack Applications for the RamSan-620 ! Low Overhead, Low Power, High Performance Databases Hot Files ! High IOPS, Bandwidth, Capacity ! Standard Management -
Validating You IO Subsystem
Validating your IO Subsystem Coming Out of the Black Box Mike Ault, Oracle Guru, TMS, Inc. A Texas Memory Systems Presentation The Black Box For most people the IO subsystem for their servers is a black box. The capacity (as defined in megabytes) is easy to confirm The performance (defined by input and output operations per second (IOPS) and latency (milliseconds, ms) may be more difficult to determine. In this paper we will explore different methodologies to obtain the IOPS and latency for your application. A Texas Memory Systems Presentation IO Is not a Black Box We are led to believe that the entire IO subsystem is out of our hands The details of the IO subsystem will make or break your database performance. Eventually almost all performance issues are traced to IO issues. A Texas Memory Systems Presentation IO is Not a Black Box Inside Oracle, views such as v$filestat and v$tempstat provide cumulative information about IO operations Using some simple queries you can determine long term averages for IOPS and latency for the files in your system. To get more granular data, tools such as Statspack and AWR must be used A Texas Memory Systems Presentation Example IO Script column sum_io1 new_value st1 noprint column sum_io2 new_value st2 noprint column sum_io new_value divide_by noprint rem select nvl(sum(a.phyrds+a.phywrts),0) sum_io1 from sys.v_$filestat a; select nvl(sum(b.phyrds+b.phywrts),0) sum_io2 from sys.v_$tempstat b; select &st1+&st2 sum_io from dual; rem ttitle 'File IO Statistics Report' spool fileio A Texas Memory