The Glass Skylight Company
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Illuminator® Tube Skylight
Illuminator® Tube Skylight A new opportunity to help add profit and value. And make every job shine. The Owens Corning® Illuminator® Tube Skylight is a smart choice for bringing natural light into the home. It’s designed to prevent leaking and is covered by a Limited Lifetime Warranty.* This warranty offers the homeowner coverage against manufacturing defects for as long as they own their home. Natural lighting. Evenly distributes up to 500 watts† of clean, natural light, helping to reduce reliance on electricity. Excellent alternative to traditional skylights. The Illuminator® Tube Skylight is cost-effective, easier to install, and features seamless, one-piece flashing designed to prevent leaking. Also provides natural light where a traditional skylight is not an option. A solution for all — naturally. Models are available for nearly all types of roofing materials — including tile and metal — and for applications in severe weather zones, such as in HVHZ. Roof Dome The Owens Corning™ Illuminator® Tube Skylight Natural lighting. Naturally easy installation. The Illuminator® Tube Skylight is easy to install with no framing, Roof Flashing drywall or electrician required and can be installed during a re-roof process or new construction – typically in less than two hours. Just follow these four simple steps: 1. Once a location is determined, use included guide to mark and cut roof, secure flashing, and install top tubing and dome. 2. Inside the home, use included guide to mark and cut ceiling, feed bottom tubing into attic, and install trim ring. 3. In the attic, insert bottom tube into trim ring and connect to top tube. -
SKYLIGHT SYSTEMS Natural Daylighting Solutions for Residential & Commercial Applications About Us
SKYLIGHT SYSTEMS Natural Daylighting Solutions for Residential & Commercial Applications About Us DRIVE TO SUCCEED Solar has been making high quality CUSTOM DESIGNS VERTICALLY INTEGRATED At Solar Innovations® Architectural systems since 1998. We began with an Ingrained in our company’s DNA is a Engineering, product testing, and product Glazing Systems, we push the envelope idea that we could not only create better “never say no” customer service attitude. design all take place within our own by continually developing more innovative products than the market was offering at This mentality has been the catalyst facility. We machine many of our own ways to build the products our customers the time, but could also introduce new for each product line offered by Solar parts, paint most of our own material, are requesting. Our deep rooted core designs that were not even a concept in Innovations® and continues to drive us and create our own custom hardware. values strengthen our commitment to our customers' or competitors' minds. to become the premier door & window, By producing as many components completing the highest quality projects Our team was small in the beginning, but glass structure, and skylight provider in within our own manufacturing facility as delivered on time. We enjoy tackling some over time as we found a talented pool North America. Some of Solar’s greatest possible, we have greater control over of the most complex projects that others of people with our same principles, we innovations have developed from cost and lead times. Superior technical in the industry will not touch, simply began to build a company that today unique customer requests that others support can also be offered for our because innovation not only creates long conquers projects of all sizes and types could not fulfill. -
Installers' Handbook Preface
HANDBOEK VOOR INSTALLATEURS Handboek voor de installatie van VELUX dakvensters Installers' handbook Preface The purpose of this handbook is to provide an overview of the installation of VELUX products. The handbook describes the various aspects of roof construction in association with VELUX roof windows and also provides advice and information on how to obtain the optimal installation. (Third edition, 2010) The VELUX system Chapter 1 2 3 4 5 6 7 8 Other products Chapter 9 Contents Planning Considerations before choosing roof window 5-13 1 Installation of a roof window Installation step by step 15-25 2 Integration – more windows Combination of more than one window 27-45 3 Special installation conditions Installation in various roof constructions 47-63 4 Special roofing materials Installation in various roof materials 65-81 5 Replacement / renovation Replacement of a roof window 83-93 6 Building physics Roof constructions (humidity, heat, sound etc) 95-109 7 Product information Short presentation of VELUX products 111-137 8 Other products Sun tunnel / Flat roof window / Solar hot water system 139-145 9 Contact VELUX Addresses / Advising / Service 146-147 List of telephone numbers 148 Size chart 151 Planning 1 The construction of the house 6-7 User requirements 8 Building regulations 9-13 VELUX 5 Planning 1 The construction of the house To be able to choose the right VELUX roof window for a given situ- ation, it is always recommended to start from the construction of the house, user requirements and current building regulations. Normally, a standard VELUX roof window can satisfy the basic requirements, but often choosing another window type or vari- ant and/or choosing accessories can optimise the function and increase the utility value of the window. -
Katalog Produktow GB 2008.Indb
ROOF WINDOWS INTRODUCTION Consultation with the architect helps make decision 8 www.fakro.com Loft Conversion-planning Building or renovation of a house is an investment which requires not only financial expenditure, but also considered decisions and solutions. Each matter should be discussed with professionals who will ad- vise the best way of solving problems. When deciding how and where to place roof windows you should consult an architect, who will help you to choose the right window type depending on the proposed use of the loft. He will also give you advice concerning the window’s glass surface area decided by the ratio to the total floor area and also where to place the win- dows to gain the maximum benefit. Nowadays roof windows are often an indispensable element of newly built structures. They create new, unique, individual possibilities. When adapting or con- The attic before conversion verting the loft and also installing roof windows your loft can be easily changed into a functional, stylish and elegant space. Depending on the client’s individ- ual requirements and the ingenuity of the architects, even the most exceptional ideas can be prepared in the form of computerised 3D visualisation of the project which helps your dreams come true. A completed conversion with two roof windows A completed conversion with four roof windows and blinds ROOF WINDOW 9 ROOF WINDOWS VERSUS DORMER When planning to develop the loft there are two options to get light in: building a dormer (until recently a very popular solution) or installing (becoming more and more popular ) modern roof windows. -
Roof Window Size Comparison
Roof Windows Roof Window Size Comparison keyliteroofwindows.com Comparison Chart Futuretherm Technology Height (mm) Width (mm) 550 660 780 940 1140 1340 01 03A 04A 07A 08A 09A Keylite CK02 N/A N/A N/A N/A N/A Velux 780 01 22 23 24 25 26 Fakro 02 03B 04 07B 08B 09 Keylite CK04 FK04 MK04 PK04 N/A UK04 Velux 980 02 03 05 15 N/A 12 Fakro 01C 03 05 07C 08 09C Keylite CK06 FK06 MK06 PK06 SK06 N/A Velux 1180 16 04 06 08 10 N/A Fakro 01F 03F 06 07F 08F 10 Keylite N/A FK08 MK08 PK08 SK08 UK08 Velux 1400 N/A N/A 07 09 11 N/A Fakro Keylite 1600 01G 03G 04G 07G 08G 09G Velux N/A N/A MK10 PK10 SK10 UK10 Fakro N/A N/A 13 N/A N/A N/A Centre Pivot Roof Windows Pine White Conservation Pine Conservation White Keylite CP WF-CP CW-CP CW-WF-CP Velux GGL GGU GGL SD5 GGU SD5 Fakro FTP-V FTU-V & PTP-V FTP-V/C PTP-V/C Top Hung / Fire Escape Pine White Conservation Pine Conservation White Keylite FE WF-FE CW-FE CW-WF-FE Velux GPL GPU GPL SD5 GPU SD5 FPP-V & FPU-V & FPP-V/C & FPU-V/C & Fakro FHP-V FHU-V FHP-V/C FHU-V/C Single Flashings Slate Tile Deep Plain Tile Conservation Conservation Conservation Conservation Corrugated Tile Slate Tile Plain Tie Deep Tile Keylite SRF TRF DTRF PTRF CWSRF CWTRF CWPTRF CWDTRF CRF (Recessed As Standard) Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Velux EDL/ EDN EDZ N/A EDW/ EDJ EDP/ N/A N/A EDN N/A N/A EDP N/A EDW EDJ ZWC EBL/ EBW/ EBP/ EKL EKW EKP Fakro EL N/A EZ N/A EH N/A EP N/A /C N/A /C N/A /C N/A /C N/A EE Combi Flashings 18mm -
Tilcor-Installation-Manual-16-EN.Pdf
INSTALLATION MANUAL BOND / CLASSIC / TUDOR / SHAKE / ROYAL / ANTICA These installation details are provided to demonstrate the recommended installation methods for Tilcor products and accessories. The details and information in this document reflect current roofing practices used in New Zealand. Consult with Tilcor Roofing Systems for additional information. Ross Roof Group Ltd +64 9 299 9498 faks +64 9 298 4114 1c Inlet Road, Takanini 2112, PO Box 72062, Papakura 2244, e-mail: [email protected] web: www.tilcor.com New Zealand 1. General Information ................................................................................. 3 2. Recommended Tools ............................................................................... 9 3. Profile and Flashing Specifications .......................................................... 10 4. Preparation of The Roof Surface for Installation ................................... 14 5. Tile (BOND, CLASSIC, TUDOR, ANTICA) Installation ............................... 16 6. Tile Installation (SHAKE, ROYAL) .............................................................. 19 7. Eaves Flashing ........................................................................................... 20 8. Box Barge Installation (Bond, Classic, Tudor, Shake, Royal) ................. 21 9. Installation of Barrels at The Ridge and Hip ............................................ 22 10. Roof Window Installation ........................................................................ 23 11. Roof Ventilation, Extractor and Sanitary -
Influence of Roof Windows Area Changes on the Classroom
sustainability Article Influence of Roof Windows Area Changes on the Classroom Indoor Climate in the Attic Space: A Case Study Erika Dolnikova * , Dusan Katunsky , Marian Vertal and Marek Zozulak Institute of Architectural Engineering, Faculty of Civil Engineering, Technical University of Kosice, 042 00 Kosice, Slovakia; [email protected] (D.K.); [email protected] (M.V.); [email protected] (M.Z.) * Correspondence: [email protected]; Tel.: +421-055-602-4162 Received: 28 April 2020; Accepted: 17 June 2020; Published: 20 June 2020 Abstract: Windows are a complex part of building design and provide a considerable benefit, including to school buildings. For the evaluation of the daylighting conditions prevailing in classrooms, the daylight factor (DF) was considered as the most appropriate parameter for indicating the quantity of admitted daylight. The DF values and CIE overcast sky were calculated using Velux Daylight Visualizer 3 software. The task of the paper is to compare various roof window openings in relation to the level of daylight in the attic, looking to optimize the use of the attic for teaching. The indoor air temperature has a general influence on comfort in the interior, in addition to daylight. In winter, the situation is not critical. The thermal insulation properties of packaging structures are sufficient. The situation is worse in summer, due to the fact that the heat-storage properties are undersized and there is excessive overheating of the indoor air. Four variants of roof windows and their influence on the overall microclimate in the attic are compared. The variant without roof windows is a suitable solution with regard to minimum overheating, but the worst situation for daylight. -
Residential Skylights
Residential skylights New installation Remodel or new construction Rooms filled with natural light and fresh air are invariably more beautiful, spacious, and uplifting to your spirits. Daylight is the essential element that transforms conventional rooms into splendid spaces. VELUX Skylights let you bring the best of the outdoors inside. Skylight replacement Three great reasons to replace skylights when you replace a roof 1. Save money - The most convenient and affordable time to replace a skylight is during re-roofing. 2. Coinciding warranty - You’re getting a new roof with a warranty, why not replace your skylight and enjoy one there as well. 3. Improved energy efficiency - Advanced LowE3 coating provides Replace Replace more daylight and better heat control. 2 VELUX 3 Choosing the right glass Recommended for out-of-reach applications Clean, Quiet & Safe glass Clean Features Neat® glass coating to keep your skylight cleaner longer, leaving skylights virtually spotless. Quiet Reduce unwanted outside noise by up to 25% compared to a standard double pane glass and up to 50% compared to a plastic skylight. Safe VELUX recommends and building Energy efficiency codes require laminated glass for 8’ out-of-reach applications. Most VELUX products are ENERGY STAR® qualified in all 50 states. Go Solar and improve energy efficiency even further! (See page 11) 10-year hail breakage warranty Clean, Quiet & Safe also available in impact, white laminated and snowload types of glass. Recommended for in-reach applications Tempered glass Consists of dual-pane, triple-coated glass with LowE3, is dual-sealed and injected with argon gas. 4 VELUX 5 Fresh air Fresh air skylights help your home breathe by bringing in fresh outside air to maintain good indoor air quality. -
Flat Roof Skylights and Hatches
FLAT ROOF SKYLIGHTS AND HATCHES DXW - walkable skylight 24x24 24x30 36x36 36x48 48x48 CURB MOUNTED FIXED SKYLIGHT FXC Infinity glass - virtually seam-free flat surface 360-degree orientation on sloped or flat roof A modern, trouble-free design helps with water run-off. White finished, PVC frame interior Internal and external accessories available before or after skylight’s installation. Suitable for roof with a pitch between 0-60 degrees DXW FXC WALKABLE SYLIGHT FXC 14x30 14x46 22x22 22x30 22x34 22x46 22x70 30x30 30x46 34x34 34x46 46x46 FLAT ROOF WINDOWS TYPE F An abundance of natural light. The window‘s profile have a secure glazing area that is up to 16% greater than those of competitors. The frame of the flat roof window is constructed from multi-chamber PVC profiles filled with insulating material. The external glass is laminated reflecting the sun rays while the internal pane is anti- burglary Class P2A. In addition to standard sizes, the type F window is available in custom sizes (from 24“x24“ to 48“x87“) to suit may retrofits. High energy-efficient DU6 triple-pane glazing (U-value=0.12 BTU/hf2F) and DU8 quadruple-pane glazing (U-value=0.11 BTU/hf2F) to choose from. INVITE Windows can be fitted with internal and external blinds to ensure shade and protect THE LIGHT DEF electric interiors from overheating. DMF manual DEF, DMF, DXF 22x22 22x30 22x46 30x30 46x46 DXF fixed FLAT ROOF ACCESS SKYLIGHT DRF Energy-efficient design using DU6 triple-pane glazing and insulated, multi-chamber PVC frame to achieve low U-value=0.13 BTU/hf2F. -
PVC Roof Windows
PVC roof windows Energy-efficient Windows Dobroplast Fabryka Okien Sp. z o.o. is a leading manufacturer of windows and doors in Poland and leading brand of the Arbonia Group, listed on the Swiss stock exchange based in Zurich and employs over 8000 people in Europe. Dobroplast is one of the largest manufacturers of windows in Europe. We offer a full range of PVC windows, entrance doors and roller blinds. The headquarters is located in Zambrów, where the company was founded in 2000. The second manufacturing site producing roof windows is located in Lublin. 2 Table of contents Advantages of Skylight windows 4 Unlimited choice Roof windows High thermal insulation 6 Termo Premium The only one in its category 8 Termo Versatile use 10 Skylight Premium Easy to clean 12 Skylight Safe and user-friendly Roof access windows Attractive and modern design 14 Skylight Termo Loft Premium and Loft Premium Easy to use 16 Skylight Termo Loft and Skylight Loft Flashings 18 Colours 19 Handles 20 Electric motors 21 Telescopic handle 21 Window ventilators 22 Interior blinds and pleated blinds 22 Overview of roof windows 23 Price list of roof windows, roof access windows and accessories 24 About us 38 Energy-efficient Windows 3 Advantages of Skylight windows Design of Dobroplast products combines practicality and effective appearance. Skylight roof windows have been created for users valuing comfort and convenience of use. Our offer includes a wide range of colours, shapes and accessories, which can be used to compose your project as you wish. Pleasant atmosphere in the flat - ensures optimal access of daylight to the rooms. -
Velux Catalog, Residential Products, Dist. by Best Materials®
Distributed by: BEST MATERIALS ® Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 www.BestMaterials.com Email: [email protected] Residential skylights Contents The VELUX House Why VELUX skylights The possibilities are endless Information 1 The VELUX House Roof windows are perfect for upper floor bonus rooms where 3 The logical choice for any skylight they will be within reach for installation easy opening. Features include 5 Choosing the right glass a sash that rotates inward for easy cleaning from the inside and a ventilation flap that allows for fresh air circulation when the window is closed. Products Pages 33-40 7 Solar Powered “Fresh Air” Skylights 11 Electric “Fresh Air” skylights Eligible for a 15 Manual “Fresh Air” skylights 19 Fixed skylights 30% Federal tax credit 25 Self-flashed skylights Receive an average of 29 Special order blinds $850* on product and installation with federal 33 Roof windows tax credit eligibility 41 Three layers of protection warranty The Solar Powered “Fresh Air” Skylight features a 43 Deck mounted flashing systems solar panel that charges an 44 Curb mounted flashing systems internal battery and control system. The skylight is remote 45 Skylight accessories controlled and solar powered, 47 SUN TUNNEL™ skylights which means it requires no additional wiring, making 53 SUN TUNNEL™ skylight accessories for easy and cost effective 55 Modular Skylights installation. An integrated 59 NEW Instant light shaft rain sensor closes the unit in case of rain and it is a No Leak Skylight, with our 3 layers of water protection, covered by our 10-year installation Testing data warranty. -
Ekl + Fs, Vs, Vse, Ggl
EKL + FS, VS, VSE, GGU, GPU, GXU ENGLISH: EKL Deck Mounted Skylight and Roof Window Flashing Installation Instructions ESPAÑOL: Instrucciones de instalación de tapajuntas EKL para tragaluz y ventana de tejado montados sobre tablero FRANÇAIS : Instructions d'installation du solin EKL pour puits de lumière et fenêtre de toit à cadre intégré montés directement sur la toiture 14°-85°15°-90° VAS 452233-2015-06 ENGLISH: Index ESPAÑOL: Índice FRANÇAIS : Index P. 2 Important installation requirements Pág. 2 Requisitos importantes de insta- P. 2 Spécifications d'installation impor- P. 4-8 Planning lación tantes P. 9-13 Installing underlayment Pág. 4-8 Planificación P. 4-8 Planification P. 13-33 Installing flashing Pág. 9-13 Instalación de la lámina de soporte P. 9-13 Installation de la membrane de toiture P. 34 GPU springs Pág. 13-33 Instalación del tapajuntas P. 13-33 Installation du solin Pág. 34 Resortes de GPU P. 34 Ressorts pour GPU ENGLISH: Important installation requirements ESPAÑOL: Requisitos importantes de instalación FRANÇAIS : Spécifications d'installation impor- Roof pitch and roofing material Inclinación del techo y material de cubierta tantes EKL is designed for roof pitches 14° - 85° EKL está diseñado para techos con inclinación Pente de toit et matériel de toiture (3:12 - 137:12) and for thin roofing materials (max de 14° - 85° (3:12 - 137:12) y para materiales de EKL est conçu pour les pentes de toit de 14° - 85° 5 5 thickness /16" (8 mm)). For roof pitches below 14° cubierta delgados (grosor máximo /16" (8 mm)). Para (3:12 - 137:12) avec matériel de toiture mince (épais- 5 (3:12) and for other roofing materials, please contact techos con inclinación inferior a 14° (3:12) y para seur maximale /16" (8 mm)).