Table of Contents
Total Page:16
File Type:pdf, Size:1020Kb
Table of Contents Thermal Expansion Valves 1-57 Solenoid Valves 58-84 Coils 85-87 Industrial Solenoid Valves 88-103 Shut Off Valves 104-105 System Protectors 106-144 Storage Devices 145-147 Oil Controls 148-155 Regulators 156-182 Temperature Pressure Controls 183-199 Page Thermal Expansion Valves 1 A-Series 2 AFA Series 5 HFK Series 7 HF Series 10 TRAE+ Valve 16 TRAE Valve 17 T-Series 19 TLE Valve 23 TI Valve 25 ZZ Valve 26 LCL Valve 28 ESVB Valve 30 EX2 Valve 32 ACP(E) Valve 34 Solenoid Valves 58 50RB 59 100RB 60 200RB 62 240RA 65 500RB 67 540RA 69 710/713RA 71 702RA 73 207CB* 74 3031RB/RC 76 RV Series* 78 703RC 80 Coils 85 Industrial Solenoid Valves 88 202C* 89 203C* 91 204C* 93 210C/211C* 95 214C* 97 222C* 99 314U* 101 Shut Off Valves ABV 104 RD 105 ACK* 134 System Protectors 106 EK 109 EKP 110 ADK 112 BFK 114 BOK-HH 116 ALF* 118 CU - Spun Copper Service Drier* 119 CU - Spun Copper Liquid Line Drier* 120 STAS 121 ADKS 122 *Also Included in the Extended Products Catalog EMERSON CLIMATE TECHNOLOGIES INDEX Page Blocks and Cores 125 BTAS* 126 ASD 128 SFD 129 CSFD 130 ASK-HH 131 ASF 132 APD 133 ACK* 134 HMI 135 AMI 136 A-IHL 138 A-IHN 138 Storage Devices A-AS* 145 AVR* 147 AOR* 148 Oil Controls W-OLC* 149 OMB* 150 A-W/A-F* 151 High Efficiency Oil Separator 152 AOFD* 153 ASF* 153 AOF* 154 AAU 155 Regulators 156 ESR 157 MTB 1 158 IPR 159 EPRB(S) 160 OPR 162 ACP(E) 163 EGR(E) 165 DGR(E) 167 CPH(E) 168 HP/HPC 170 Temperature Pressure Controls 183 TS1 184 PS1 188 PS2 190 FD113 192 PS3 193 FS 196 FF4 198 FF444 199 Troubleshooting Guide 200 Competitive Cross Reference 207 INDEX EMERSON CLIMATE TECHNOLOGIES Also Included in the Extended Products Catalog Alpha Numeric By Product Product Page Product Page 50RB 59 BTAS* 126 100RB 60 Coils 85 200RB 62 CPH(E) 168 202C* 89 CSFD 130 203C* 91 CU - Liquid Line* 121 204C* 93 CU - Service Drier* 120 207CB* 74 DGR(E) 167 210C/211C* 95 EGR(E) 165 214C* 97 EK 109 222C* 99 EKP 110 240RA 65 EPRB(S) 160 314U* 101 ESR 157 500RB 67 ESVB 32 540RA 69 EX2 34 703RC 80 FD113 192 710/713RA 71 FF4 198 3031RB/RC 76 FF444 199 A-Series 2 FS 196 A-AS* 145 HF 10 AAU 155 HFK 7 ABV* 104 HMI 135 ACK* 134 HP/HPC 170 ACP(E) 34 IPR 159 ADK 112 LCL 28 ADKS 122 MTB 1 158 A-F* 151 OMB* 150 AFA 5 OPR 162 A-IHL 138 OS 152 A-IHN 138 PS1 188 ALF* 118 PS2 190 AMI 136 PS3 193 AOF* 154 RD 105 AOFD* 153 RV* 78 AOR* 148 SFD 129 APD 133 STAS 121 ASD 126 T-Series 19 ASF 132 TI 25 ASF* 153 TLE 23 ASK-HH 131 TRAE 17 AVR* 147 TRAE+ 16 A-W* 151 TS1 184 BFK 114 W-OLC* 149 Blocks and Cores 125 ZZ 26 BOK-HH 116 *Also Included in the Extended Products Catalog EMERSON CLIMATE TECHNOLOGIES INDEX THERMAL EXPANSION VALVE QUICK SELECT GUIDE STYLE NOMINAL REPLACEABLE CONNECTIONS CONFIGURATION PORT CAPACITY VALVE CATALOG SERVICE POWER FIELD ADJUSTABLE INTERNAL APPLICATION (R-22) FAMILY PAGE REPLACEMENT HERMETIC ELEMENT ASSEMBLED SAE ODF ANGLE STRAIGHT CONVENTIONAL BALANCED SUPERHEAT CHECK 1/4 to 5 AA 2 X XXXX 1/4 to 5 AN 2 X XXXX 1/4 to 5 AAC 4 XX X XX XX 1/4 to 5 ANC 4 X XXXX X 1/4 to 5 AFA 5XX X X X X 1/3 to 5 TI 25X XXXXX 1/4 to 5 1/2 HFK 7 X X XXXXX XX AIR 1/4 to 5 1/2 HF 10XXXXXXX CONDITIONING 8 to 20 HF EXT 10 X X X X X X AND 1/2 to 12 TL 23 XXXXXX REFRIGERATION 1/2 to 12 TCL 19X XXXXXX X 11 and 14 TJL 19X X XXXX X 14 and 18 TJR 19 X X X X X X X 22 to 45 TER 19 X X X X X X X 55 TIR 19 X X X X X X X 70 and 85 THR 19 X X X X X X X 100 TMR 19 X X X X X X 10 to 40 TRAE+ 16 X X X X X 50 to 70 TRAE 17 X X X X X CONSTANT PRESSURE 1/2 to 5 ACP 34 X X X X ELECTRICALLY 1 to 20 ESVB 30 X X X N/A N/A DRIVEN 1/4 to 4 EX2 32 X X X N/A N/A ULTRA-LOW TEMP 3/4 to 8 ZZ 26 XXXXXX X De-Superheating LCL 28 XXXXXX X EMERSON CLIMATE TECHNOLOGIES 1 THERMO® EXPANSION VALVE QUICK SELECT GUIDE A-SERIES THERMO® EXPANSION VALVE “A” Series Thermo Expansion Valves are used for heat pump, air conditioning, food service and commercial applications. “A” Series valves provide stable and accurate control over a wide range of operating conditions. FEATURES Hermetic construction eliminates external leakage Compact size allows installation in limited spaces Mass spectrometer tested to ensure less than 0.10 oz/year external leakage rate Stainless steel power element eliminates corrosion and prevents valve failure OPTIONS HAA wide range charge allows two valves ( 2 1/2 and SPECIFICATIONS 5 ton, R-22) to cover all capacities from 1 to 5 tons on Maximum working pressure: 700 psig most residential systems UL Recognized: SA 5312 New ZW195 charge available for R-410A systems Available adjustable or non-adjustable superheat for Extended Capacity Tables begin on page 36. application flexibility Ordering Information begins on page 3. SAE or ODF connections standard – chatleff or aeroquip are available Available external or internal equalizer to satisfy the broadest possible range of applications Available internal check valve allows reverse flow heat pump applications, eliminating the need for external piping and external check valve, thus reducing installation costs (ANC Series) Bleed type pressure equalization available to accommodate PSC type compressors Pressure limiting charges (MOP) available – consult factory NOMENCLATURE EXAMPLE: AACEB 2 HC 30 IN 3/8 X 1/2 ODF ANG A A C E B 2 H C 30 IN 3/8 x 1/2 ODF ANG Valve Superheat Adjustment Internal Equalizer Bleed Hole Capacity Refrigerant Charge Capillary Inlet x Outlet Connection Config- Series Check (optional) Nominal Rating Code Code Tube Connection Type uration Economy, A = Adjustable Valve E=External in Tons F = R12 Length Sizes SAE = Hermetic (optional) Omit for H = R22 C = medium temp I O flare S/T = Design N = Non-Adjustable Reverse (Omit for no bleed See nominal M = R134a CA = heat pump 30 IN (std) 1/4 3/8 ODF = straight- Flow Internal) hole capacity N = R407C W(MOP)=press. limiting other 3/8 1/2 solder thru Bypass table P = R507 Z = low temp lengths are 1/2 5/8 Chatleff Application below R = R502 AA = wide range available 5/8 7/8 (optional) ANG = S = R404A Aeroquip 90° Z = R410A (optional) angle AA/AN SERIES – NOMINAL CAPACITY TABLE IN TONS R12 R134a R22 R410A R502 R507/R404A R407C – 1/8 1/5 – – 1/8 1/5 1/8 1/4 1/4 1/4 1/8 1/4 1/4 1/4 1/2 1/2 1/2 1/4 1/2 1/2 1/2 3/4 1 1 1/2 3/4 1 1 1 1½ 1½ 1 1 1¼ –1½22–1¼2 1½ 2 2½ 3 1½ 2 2½ 2 2½ 3 4 2 2¼ 3¼ 2½ 3 4 5 2½ 2½ 4 345–33½5¼ 2 EMERSON CLIMATE TECHNOLOGIES ORDERING INFORMATION FOR A-SERIES VALVES VALVE CAPACITY CAP PCN BY CHARGE CONNECTIONS SERIES TONS TUBE FC MC MZ HC HW100 HAA SC SZ SW45 ZW195 R-12 Mep. Temp R-134a Med. Temp R-134a Low Temp R-22 Mep. Temp R-22 MOP R-22 Wide Range R-404A Med. Temp. R-404A Low Temp. R-404A MOP R-410A Wide Range 1/4 X 1/2 ODF S/T 063503 30 IN. 1/4 X 3/8 ODF S/T 065202 1/4 1/4 X 1/2 ODF S/T 064302 065623 055932 1/4 X 3/8 ODF S/T 048986 056315 065675 065676 5 FT. 1/4 X 3/8-1/2 SAE S/T 049820 AA 062797 065624 065626 065682 065685 1/4 X 1/2 ODF S/T 063504 1/2 1/4 X 3/8 SAE S/T 058986 30 IN. 063925 3/8 X 1/2 ODF S/T 3/4 065149 065686 1/4 X 1/2 ODF S/T 065628 065630 065632 065636 1/2 3/8 X 1/2 ODF S/T 065633 065687 065688 1/4 X 1/2 ODF S/T 065634 1 5 FT. 3/8 X 1/2 ODF S/T 062798 065631 065635 065183 065637 1-1/2 3/8 X 1/2 ODF S/T 064424 065697 065698 064425 065689 065690 23/8 X 1/2 ODF S/T 30 IN. 065330 059815 1/2 x 5/8 ODF S/T 5 FT. 065691 065148 2-1/2 3/8 X 1/2 ODF S/T 063648 AAE 30 IN. 013938 CHATLEFF 015776 3/8 X 1/2 ODF S/T 5 FT. 062376 065692 065693 3 3/8 X 1/2 ODF S/T 065579 30 IN.