Semiconductor Detectors Part 1

Total Page:16

File Type:pdf, Size:1020Kb

Semiconductor Detectors Part 1 1 Lectures on Detector Techniques Stanford Linear Accelerator Center September 1998 – February, 1999 Semiconductor Detectors Part 1 Helmuth Spieler Physics Division Lawrence Berkeley National Laboratory for more details see UC Berkeley Physics 198 course notes at http://www-physics.lbl.gov/~spieler Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 2 1. Principles Important excitations when radiation is absorbed in solids 1. atomic electrons ⇒ mobile charge carriers ⇒ lattice excitations (phonons) 2. elastic scattering on nuclei Recoil energy < order 10 eV ⇒ ionization ⇒ lattice excitations (phonons) at higher recoil energies ⇒ radiation damage (displacement of from lattice sites) Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 3 Most Semiconductor Detectors are Ionization Chambers Detection volume with electric field Energy deposited → positive and negative charge pairs Charges move in field → current in external circuit (continuity equation) Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 4 Ionization chambers can be made with any medium that allows charge collection to a pair of electrodes. Medium can be gas liquid solid Crude comparison of relevant properties gas liquid solid density low moderate high atomic number Z low moderate moderate ionization energy εi moderate moderate low signal speed moderate moderate fast Desirable properties: low ionization energy ⇒ 1. increased charge yield dq/dE 2. superior resolution ∆ E ∝ 1 ∝ 1 ∝ ε ε i E N E / i high field in detection volume ⇒ 1. fast response 2. improved charge collection efficiency (reduced trapping) Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 5 Ionization energy in solids is proportional to the band gap small band gap ⇒ ~ conductor electric field small DC current >> signal current large band gap ⇒ insulator high electric field small signal charge + small DC current example: diamond moderate band gap ⇒ semiconductor high electric field “large” signal charge small DC current, but “pn-junction” required. examples: Si, Ge, GaAs Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 6 Principle of Semiconductor Detector 1. Energy absorbed in semiconductor ⇒ formation of mobile electrons and holes number of electron-hole pairs in Si: E N = ε i E= absorbed energy, εi= 3.6 eV 2. Electric field in detection volume causes electrons and holes to move towards electrodes typical transit times: 10 – 20 ns for 300 µm 3. Induced signal current measured typical signal charge: 3.5 fC (22000 el) for minimum ionizing particles traversing 300 µm of Si Semiconductor technology allows micron-scale patterning of electrodes ⇒ strip and pixel detectors Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 7 Example: Strip Detectors Resolution determined by precision of micron scale patterning (e.g. strips on 50 µm pitch) Two options: Binary Readout Analog Readout Interpolation yields resolution < pitch Relies on transverse diffusion σ ∝ x tcoll to discriminators e.g. in Si Position resolution determined tcoll≈ 10 ns directly by pitch ⇒ σx= 5 µm σ = x pitch / 12 Interpolation precision depends on S/N and p p= 25 µm and S/N=50 ⇒ 3 – 4 µm resolution Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 8 Energy required for creation of an electron-hole pair Ionization Energy > Band Gap Formation of e-h pair requires both … 1. Conservation of energy 2. Conservation of momentum ⇒ additional energy excites phonons Remarkably, εi /Eg ≈ const for all materials, types of radiation. C.A. Klein, J. Applied Physics 39 (1968) 2029 Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 9 Fluctuations in the Signal Charge: the Fano Factor The mean ionization energy exceeds the bandgap for two reasons 1. Conservation of momentum requires excitation of lattice vibrations 2. Many modes are available for the energy transfer with an excitation energy less than the bandgap. Two types of collisions are possible: a) Lattice excitation, i.e. phonon production (with no formation of mobile charge). b) Ionization, i.e. formation of a mobile charge pair. Assume that in the course of energy deposition Nx excitations produce NP phonons and Ni ionization interactions form NQ charge pairs. On the average, the sum of the energies going into excitation and ionization is equal to the energy deposited by the incident radiation = + E0 Ei Ni Ex N x where Ei and Ex are the energies required for a single excitation or ionization. Assuming gaussian statistics, the variance in the number of excitations σ = x N x and the variance in the number of ionizations σ = i Ni Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 10 For a single event, the energy E0 deposited in the detector is fixed (although this may vary from one event to the next). If the energy required for excitation Ex is much smaller than required for ionization Ei, sufficient degrees of freedom will exist for some combination of ionization and excitation processes to dissipate precisely the total energy. Hence, for a given energy deposited in the sample a fluctuation in excitation must be balanced by an equivalent fluctuation in ionization. ∆ + ∆ = Ex N x Ei Ni 0 If for a given event more energy goes into charge formation, less energy will be available for excitation. Averaging over many events this means that the variances in the energy allocated to the two types of processes must be equal σ = σ Ei i Ex x σ = Ex i N x Ei From the total energy Ei Ni + Ex Nx = E0 − = E0 Ei Ni N x Ex yielding σ = Ex E0 − Ei i Ni Ei Ex Ex Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 11 Since each ionization leads to a charge pair that contributes to the signal E N = N = 0 i Q ε i where εi is the average energy loss required to produce a charge pair, σ = Ex E0 − Ei E0 i ε Ei Ex Ex i E E ε σ = 0 ⋅ x i −1 i ε i Ei Ei The second factor on the right hand side is called the Fano factor F. Since σi is the variance in signal charge Q and the number of charge pairs is NQ=E0 /εi σ = Q FNQ In Silicon Ex= 0.037 eV Ei = Eg= 1.1 eV εi = 3.6 eV for which the above expression yields F= 0.08, in reasonable agreement with the measured value F= 0.1. ⇒ The variance of the signal charge is smaller than naively expected σ ≈ Q 0.3 NQ Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 12 A similar treatment can be applied if the degrees of freedom are much more limited and Poisson statistics are necessary. However, when applying Poisson statistics to the situation of a fixed energy deposition, which imposes an upper bound on the variance, one can not use the usual expression for the variance var N = N Instead, the variance is (N − N )2 = F N as shown by Fano [1] in the original paper. An accurate calculation of the Fano factor requires a detailed accounting of the energy dependent cross sections and the density of states of the phonon modes. This is discussed by Alkhazov [2] and van Roosbroeck [3]. References: 1. U. Fano, Phys. Rev. 72 ( 1947) 26 2. G.D. Alkhazov et al., NIM 48 (1967) 1 3. W. van Roosbroeck, Phys. Rev. 139 (1963) A1702 Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 13 Intrinsic Resolution of Semiconductor Detectors E ∆E = 2.35⋅ ε FN = 2.35⋅ε F = 2.35⋅ FEε i Q i w i Si: εi= 3.6 eV F= 0.1 Ge: εi= 2.9 eV F= 0.1 Intrinsic Resolution of Si and Ge Detectors 250 200 Si 150 Ge E FWHM [eV] 100 ∆ 50 0 0 5 10 15 20 25 E [keV] Detectors with good efficiency for this energy range have sufficiently small capacitance to allow electronic noise of ~100 eV FWHM, so the variance of the detector signal is a significant contribution. At energies >100 keV the detector sizes required tend to increase the electronic noise to dominant levels. Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 14 Semiconductor Crystals Lattice structure of diamond, Si, Ge (“diamond lattice”) (from Schockley) dimension a: lattice constant Diamond: 3.56 Å Ge: 5.65 Å Si: 5.43 Å Extent of wavefunctions of typical constituent atoms: (from Schockley) Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 15 When isolated atoms are brought together to form a lattice, the discrete atomic states shift to form energy bands: (from Harrison) Filled band formed by bonding states: Ψ= Ψa + Ψa (Ψa = wavefunction of individual atom) Empty band formed by anti-bonding states: Ψ= Ψa − Ψa (vanishing occupancy at mid-point between atoms) Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 16 Each atom in the lattice contributes its quantum states to each band: The number of quantum states in the band is equal to the number of states from which the band was formed. The bands are extended states, i.e. the state contributed by an individual atom extends throughout the crystal. Energy band structure (from Schockley) Typical band gaps (valence – conduction band) Ge 0.7 eV GaAs 1.4 eV Si 1.1 eV Diamond 5.5 eV Semiconductor Detectors Helmuth Spieler SLUO Lectures on Detector Techniques, October 23, 1998 LBNL 17 At 0K all electrons occupy bonding states, completely filling the valence band.
Recommended publications
  • Army Radio Communication in the Great War Keith R Thrower, OBE
    Army radio communication in the Great War Keith R Thrower, OBE Introduction Prior to the outbreak of WW1 in August 1914 many of the techniques to be used in later years for radio communications had already been invented, although most were still at an early stage of practical application. Radio transmitters at that time were predominantly using spark discharge from a high voltage induction coil, which created a series of damped oscillations in an associated tuned circuit at the rate of the spark discharge. The transmitted signal was noisy and rich in harmonics and spread widely over the radio spectrum. The ideal transmission was a continuous wave (CW) and there were three methods for producing this: 1. From an HF alternator, the practical design of which was made by the US General Electric engineer Ernst Alexanderson, initially based on a specification by Reginald Fessenden. These alternators were primarily intended for high-power, long-wave transmission and not suitable for use on the battlefield. 2. Arc generator, the practical form of which was invented by Valdemar Poulsen in 1902. Again the transmitters were high power and not suitable for battlefield use. 3. Valve oscillator, which was invented by the German engineer, Alexander Meissner, and patented in April 1913. Several important circuits using valves had been produced by 1914. These include: (a) the heterodyne, an oscillator circuit used to mix with an incoming continuous wave signal and beat it down to an audible note; (b) the detector, to extract the audio signal from the high frequency carrier; (c) the amplifier, both for the incoming high frequency signal and the detected audio or the beat signal from the heterodyne receiver; (d) regenerative feedback from the output of the detector or RF amplifier to its input, which had the effect of sharpening the tuning and increasing the amplification.
    [Show full text]
  • 3 Gamma-Ray Detectors
    3 Gamma-Ray Detectors Hastings A Smith,Jr., and Marcia Lucas S.1 INTRODUCTION In order for a gamma ray to be detected, it must interact with matteu that interaction must be recorded. Fortunately, the electromagnetic nature of gamma-ray photons allows them to interact strongly with the charged electrons in the atoms of all matter. The key process by which a gamma ray is detected is ionization, where it gives up part or all of its energy to an electron. The ionized electrons collide with other atoms and liberate many more electrons. The liberated charge is collected, either directly (as with a proportional counter or a solid-state semiconductor detector) or indirectly (as with a scintillation detector), in order to register the presence of the gamma ray and measure its energy. The final result is an electrical pulse whose voltage is proportional to the energy deposited in the detecting medhtm. In this chapter, we will present some general information on types of’ gamma-ray detectors that are used in nondestructive assay (NDA) of nuclear materials. The elec- tronic instrumentation associated with gamma-ray detection is discussed in Chapter 4. More in-depth treatments of the design and operation of gamma-ray detectors can be found in Refs. 1 and 2. 3.2 TYPES OF DETECTORS Many different detectors have been used to register the gamma ray and its eneqgy. In NDA, it is usually necessary to measure not only the amount of radiation emanating from a sample but also its energy spectrum. Thus, the detectors of most use in NDA applications are those whose signal outputs are proportional to the energy deposited by the gamma ray in the sensitive volume of the detector.
    [Show full text]
  • 1. Gamma-Ray Detectors for Nondestructive Analysis P
    1. GAMMA-RAY DETECTORS FOR NONDESTRUCTIVE ANALYSIS P. A. Russo and D. T. Vo I. INTRODUCTION AND OVERVIEW Gamma rays are used for nondestructive quantitative analysis of nuclear material. Knowledge of both the energy of the gamma ray and its rate of emission from the unknown mass of nuclear material is required to interpret most measurements of nuclear material quantities. Therefore, detection of gamma rays for nondestructive analysis of nuclear materials requires both spectroscopy capability and knowledge of absolute specific detector response. Some techniques nondestructively quantify attributes other than nuclear material mass, but all rely on the ability to distinguish elements or isotopes and measure the relative or absolute yields of their corresponding radiation signatures. All require spectroscopy and most require high resolution. Therefore, detection of gamma rays for quantitative nondestructive analysis (NDA) of the mass or of other attributes of nuclear materials requires spectroscopy. A previous book on gamma-ray detectors for NDA1 provided generic descriptions of three detector categories: inorganic scintillation detectors, semiconductor detectors, and gas-filled detectors. This report described relevant detector properties, corresponding spectral characteristics, and guidelines for choosing detectors for NDA. The current report focuses on significant new advances in detector technology in these categories. Emphasis here is given to those detectors that have been developed at least to the stage of commercial prototypes. The type of NDA application – fixed installation in a count room, portable measurements, or fixed installation in a processing line or other active facility (storage, shipping/receiving, etc.) – influences the choice of an appropriate detector. Some prototype gamma-ray detection techniques applied to new NDA approaches may revolutionize how nuclear materials are quantified in the future.
    [Show full text]
  • HP 423A Crystal Detector
    Errata Title & Document Type: 423A and 8470A Crystal Detector Operating and Service Manual Manual Part Number: 00423-90001 Revision Date: July 1976 About this Manual We’ve added this manual to the Agilent website in an effort to help you support your product. This manual provides the best information we could find. It may be incomplete or contain dated information, and the scan quality may not be ideal. If we find a better copy in the future, we will add it to the Agilent website. HP References in this Manual This manual may contain references to HP or Hewlett-Packard. Please note that Hewlett- Packard's former test and measurement, life sciences, and chemical analysis businesses are now part of Agilent Technologies. The HP XXXX referred to in this document is now the Agilent XXXX. For example, model number HP8648A is now model number Agilent 8648A. We have made no changes to this manual copy. Support for Your Product Agilent no longer sells or supports this product. You will find any other available product information on the Agilent Test & Measurement website: www.agilent.com Search for the model number of this product, and the resulting product page will guide you to any available information. Our service centers may be able to perform calibration if no repair parts are needed, but no other support from Agilent is available. OPERATING AND SERVICE MANUAL - I 423A 8470A CRYSTAL DETECTOR HEWLETT~PACKARD Plint.d: JUtY 191& e H.",len Packard Co. \910 1 " • .' • I .... ,. ", - \, . '. ~ ~.. ". ." , .' " . ..... " 'I. "",:,. • ' Page 2 i\lodel ·123A/8470A 1. GENERAL INFORMATION 10.
    [Show full text]
  • DRC-2016-012921.Pdf
    CLN-SRT-011 R1.0 Page 2 of 33 Introduction ................................................................................................................................ 3 Sources of Radiation .................................................................................................................. 3 Radiation: Particle vs Electromagnetic ....................................................................................... 5 Ionizing and non- ionizing radiation ............................................................................................ 8 Radioactive Decay ....................................................................................................................10 Interaction of Radiation with Matter ...........................................................................................15 Radiation Detection and Measurement .....................................................................................17 Biological Effects of Radiation ...................................................................................................18 Radiation quantities and units ...................................................................................................18 Biological effects .......................................................................................................................20 Effects of Radiation by Biological Organization .........................................................................20 Mechanisms of biological damage ............................................................................................21
    [Show full text]
  • Crystal Receivers for Broadcast Reception
    CRYSTAL RECEIVERS FOR BROADCAST RECEPTION BY PERCY W. HARRIS AUTH OR OF "THE A B C OF WIRELE SS " R E-C EI\·I~ G A \':I R EL l':': SS C c:' .''':CERT \\Tf1r :\ HO]\IE-l\[.-\DE C RYSTAL \;ECEI\ -EI~ LONDON THE WIRELESS PRESS, LTD. t 2 & I3, HENRIETTA STREET, w.e. 2 A HOME- MADE C R Y ST AL RECEIVER WITH ADJUSTME NTS F OR B R OADCAST 'NAVE-LE N GTHS A N D E I F F EL T OW E R TIME­ SI GN ALS. I N ST R UCTIONS FOR BUILDING T H I S S E T ARE G IVEN IN CHAP T E R X , CRYSTAL RECEIVERS FOR BROADCAST RECEPTION BY PERCY \Y HARIUS A UTHOR OF "THE A 13 C OF W I R ELESS," ETC. LOND ON THE WIRELESS PRESS, LTD. 1 2 & 13, HENRIETTA STREET, W.c. 2 NEW YORK: ,\VIlmLESS PRESS INC., 326 BIWADWAY THE WIRELESS PRESS, LTD. FOREIGN AND CO LOAIAL AGEiVCIES: SYDNEY, N.S.vV.: 97, Clarence Street. MELBOURNE: 422 (4, Little CoUins Street. MADRID: La Prensa Radiotelegrafica, 43, Calle de Alcala. GENOA: Agenzia Radiotelegrafica Italiana, Via Varese 3. AMSTERDAM: Nederlandsch Persbureau Radio, 562, Keizersgracht. INTRODUCTION THE advent of broadcast radio-telephony has aroused con­ siderable interest in the simple forms of wireless receiver, with the result that the crystal detector, \vhich was fast being ousted by the thermionic valve, has once again become popular. Numerous crystal receivers are now on the market, and the beginner in wireless may well feel some con­ fusion as to their merits.
    [Show full text]
  • History of Diode
    HISTORY OF DIODE In electronics, a diode is a two-terminal electronic component that conducts electric current in only one direction. The term usually refers to a semiconductor diode, the most common type today, which is a crystal of semiconductor connected to two electrical terminals, a P-N junction. A vacuum tube diode, now little used, is a vacuum tube with two electrodes; a plate and a cathode. The most common function of a diode is to allow an electric current in one direction (called the diode's forward direction) while blocking current in the opposite direction (the reverse direction). Thus, the diode can be thought of as an electronic version of a check valve. This unidirectional behavior is called rectification, and is used to convert alternating current to direct current, and extract modulation from radio signals in radio receivers. However, diodes can have more complicated behavior than this simple on-off action, due to their complex non-linear electrical characteristics, which can be tailored by varying the construction of their P-N junction. These are exploited in special purpose diodes that perform many different functions. Diodes are used to regulate voltage (Zener diodes), electronically tune radio and TV receivers (varactor diodes), generate radio frequency oscillations (tunnel diodes), and produce light (light emitting diodes). Diodes were the first semiconductor electronic devices. The discovery of crystals' rectifying abilities was made by German physicist Ferdinand Braun in 1874. The first semiconductor diodes, called cat's whisker diodes were made of crystals of minerals such as galena. Today most diodes are made of silicon, but other semiconductors such as germanium are sometimes used.
    [Show full text]
  • Portable Front-End Readout System for Radiation Detection
    Portable Front-End Readout System for Radiation Detection by Maris Tali THESIS for the degree of MASTER OF SCIENCE (Master in Electronics) Faculty of Mathematics and Natural Sciences University of Oslo June 2015 Det matematisk- naturvitenskapelige fakultet Universitetet i Oslo Portable Front-End Readout System for Radiation Detection Maris Tali Portable Front-End Readout System for Radiation Detection Maris Tali Portable Front-End Readout System for Radiation Detection Acknowledgements First of all, I would like to thank my advisor, Ketil Røed, for giving me the opportunity to write my master thesis on such an interesting and challenging subject as radiation instrumentation and measurement. I would also like to thank him for his insight and guidance during my master thesis and for the exciting opportunities during my studies to work in a real experimental environment. I would also like to thank the Electronic Laboratory of the University of Oslo, specif- ically Halvor Strøm, David Bang and Stein Nielsen who all gave me valuable advice and assistance and without whom this master thesis could not have been finished. Lastly, I would like to thank the co-designer of the system whom I worked together with during my master thesis, Eino J. Oltedal. It is customary to write that half of ones master thesis belongs to ones partner. However, this is actually the case in this instance so I guess 2/3 of my master thesis is yours and I definitely could not have done this without you. So, thank you very much! Oslo, June 2015 Maris Tali I Maris Tali Portable Front-End Readout System for Radiation Detection Contents Acknowledgments I Glossary VI List of Figures X List of Tables X Abstract XI 1 Introduction 1 1.1 Background and motivation .
    [Show full text]
  • EECS 117A Demonstration 2 Microwave Measurement Instruments
    University of California, Berkeley Spring 2007 EECS 117 Prof. A. Niknejad EECS 117A Demonstration 2 Microwave Measurement Instruments NAME Introduction. Please review the general sinusoidal wave concepts in Secs. 3.1–3.9 of Inan & Inan. Note carefully Section 3.3. In this demonstration you will learn how to use a “50 ohm” slotted line, crystal detector, and standing wave ratio meter to obtain the wavelength λ and voltage standing wave ratio S on a coaxial transmission line. In a later demonstration you will use these techniques to measure and control impedances and reflection coefficients on a microwave transmission system. The apparatus used is shown below. The slotted line is a (rigid) continuation of the coaxial transmission lines “a” connected at each end. It has a thin slot in its outer conductor, cut along z. A probe rides within (but not touching) the slot to sample the transmission line voltage. The probe can be moved along z, and can also be moved into and out of the slot by means of a micrometer. The probe is connected to a crystal (diode) detector that converts the time-varying microwave voltage to dc. The dc voltage is measured using the standing wave ratio (SWR) meter. MICROMETER HP 415D b SWR METER DETECTOR TUNER HP 612 A UHF SIGNAL a TERMINATION GENERATOR a GR SLOTTED LINE POINT (LOAD) Z = 0 Z Suppose a sinusoidal voltage wave j(ωt−βz) v+(t) = Re hV+ e i (1) travels from the RF generator through the slotted line and is incident on a load (resistor, capacitor etc.) at z = 0.
    [Show full text]
  • The Crystal Radio
    The Crystal Radio: An Inexpensive Form of Mass Communication Christopher Manxhari Massachusetts Academy of Math & Science at Worcester Polytechnic Institute Manxhari 1 Introduction Technology has always been developing, and with it so have methods and access to communication. One such example is the internet, which has been rapidly growing in the past years. Yet, despite all of these advancements, there is still a large population that lacks internet. During distraught times, such as the coronavirus pandemic, having access to information is important, but not everyone is able to access urgent information. Roughly 10% of the United States population does not have access to the internet (Anderson, Perrin, Jiang, & Kumar, 2020). This proportion translates to over 30 million United States citizens, which is quite a substantial population size. In fact, there appears to be a correlation between income level and the proportion of those in a certain economic bracket that have internet. At an annual income of less than $30,000, 18% of citizens lack access to the internet. Withal, 7% of those making between $30,000 and $50,000 annually, 3% of those making $50,000 to $75,000 annually, and 2% of those making anything upwards annually lack that access (Anderson ​ ​ et al., 2020). See Figure 1 for more data on the ​ ​ ​ ​ demographics of those using the internet. It is evident that one’s income level is positively correlated with higher frequencies of internet usage. The internet is but one of many mediums of mass communication, and it is certainly one dominating form. As of 2018, roughly 41% of U.S.
    [Show full text]
  • Semiconductor Detectors Silvia Masciocchi GSI Darmstadt and University of Heidelberg
    Semiconductor detectors Silvia Masciocchi GSI Darmstadt and University of Heidelberg 39th Heidelberg Physics Graduate Days, HGSFP Heidelberg October 10, 2017 Semiconductor detector: basics IONIZATION as in gas detectors → Now in semiconductors = solid materials with crystalline structure (Si, Ge, GaAs) → electron-hole pairs (instead of electron-ion) + use microchip technology: structures with few micrometer precision can be produced at low cost. Read-out electronics can be directly bonded to the detectors + only a few eV per electron-hole pair → 10 times more charge produced (wrt gas) → better energy resolution + high density compared to gases → need only thin layers (greater stopping power) – apart from silicon, the detectors need to be cooled (cryogenics) – crystal lattices → radiation damage [email protected] Semiconductor detectors, October 11, 2017 2 Applications Main applications: ● γ spectroscopy with high energy resolution ● Energy measurement of charged particles (few MeV) and particle identification (PID) via dE/dx (multiple layers needed) ● Very high spatial resolution for tracking and vertexing A few dates: 1930s – very first crystal detectors 1950s – first serious developments of particle detectors 1960s – energy measurement devices in commerce [email protected] Semiconductor detectors, October 11, 2017 3 Semiconductor detectors: outline ● Principle of operation of semiconductor detectors ● Properties of semiconductors (band structure) ● Intrinsic material ● Extrinsic (doped) semiconductors ● p-n junction ● Signal generation ● Energy measurement with semiconductor detectors ● Position measurement with semiconductor detectors ● Radiation damage [email protected] Semiconductor detectors, October 11, 2017 4 Principle of operation ● Detector operates as a solid state ionization chamber ● Charged particles create electron-hole pairs ● Place the crystal between two electrodes that set up an electric field → charge carriers drift and induce a signal ● Less than 1/3 of energy deposited goes into ionization.
    [Show full text]
  • Internal and External Exposure Exposure Routes 2.1
    Exposure Routes Internal and External Exposure Exposure Routes 2.1 External exposure Internal exposure Body surface From outer space contamination and the sun Inhalation Suspended matters Food and drink consumption From a radiation Lungs generator Radio‐ pharmaceuticals Wound Buildings Ground Radiation coming from outside the body Radiation emitted within the body Radioactive The body is equally exposed to radiation in both cases. materials "Radiation exposure" refers to the situation where the body is in the presence of radiation. There are two types of radiation exposure, "internal exposure" and "external exposure." External exposure means to receive radiation that comes from radioactive materials existing on the ground, suspended in the air, or attached to clothes or the surface of the body (p.25 of Vol. 1, "External Exposure and Skin"). Conversely, internal exposure is caused (i) when a person has a meal and takes in radioactive materials in the food or drink (ingestion); (ii) when a person breathes in radioactive materials in the air (inhalation); (iii) when radioactive materials are absorbed through the skin (percutaneous absorption); (iv) when radioactive materials enter the body from a wound (wound contamination); and (v) when radiopharmaceuticals containing radioactive materials are administered for the purpose of medical treatment. Once radioactive materials enter the body, the body will continue to be exposed to radiation until the radioactive materials are excreted in the urine or feces (biological half-life) or as the radioactivity weakens over time (p.26 of Vol. 1, "Internal Exposure"). The difference between internal exposure and external exposure lies in whether the source that emits radiation is inside or outside the body.
    [Show full text]