Craguns Resort Map Winter.Indd

Total Page:16

File Type:pdf, Size:1020Kb

Craguns Resort Map Winter.Indd * * CAUTIO*N * * OPEN WATER!** . I NG GULL LAKE Steamboat Bay RK PA T R A I L E R BEACH CABINS Ice Fishing Houses Kitty Cat CAUTION Snowmobile Track Ice Rink *** OPEN WATER! * Outdoor * * Pool Gull Lake Cruises Dock Sledding * Hill * BEACH CABINS * LAKEVIEW * CABIN Marina H I Snowmobiles Rentals J K L Cabana SHORELINE Café Arcade HILLTOP Closed For SUITES The Season G Whirlpool 343-345 371 P ARKING F LAKEVIEW E Lobby RNQ CABINS BAYVIEW VILLAS D Indoor S HOSPITALITY P M 684 685 LAKEVIEW CABINS V ROOM 340 686 687 C Pool 688 689 W B Sports P ARKING Centre ARKING P ARKING P ARKING ARKING S P T P HILLSIDE CABIN SELFIE STATION U #craguns CABIN A 115 TRAILER PARKING RKING Nisswa PA Welcome to HILLSIDE CABINS Dog Sled Rides 77 G RKIN PA Cross Country T R A I L E R Skiing DINING LAUNDRY FACILITIES VENDING MACHINES Lakeside Dining Room Poolside, by Room 230 Shoreline Suites Skyway Mount Cabana Café Shoreline Suites, by Room 280 Ski Gull Bear Trap Lounge FIREWOOD GULL Irma’s Kitchen (Seasonal) BEVERAGE MACHINES Please call Ext. 8700 for Legacy Grille (Seasonal) Lobby delivery and instructions 77 LAKE 371 Gull Lake Cruises (Seasonal) Marina The Centre ICE MACHINES Shoreline Suites Skyway LOCATED AT THE CRAGUN’S Near Room 200 Near Room 150 LEGACY COURSES: 125 Near Room 200 Poolside, Near Room 225 Legacy Grille (Seasonal) Maps not to scale. Updated 11/19 Near Room 212 Near Hospitality Room 332-333 Pavilion 70 Poolside, Near Room 225 Near Room 545 Audubon Room 1-800-CRAGUNS (1-800-272-4867) Near Hospitality Room 340 Near Paul Bunyan Meeting LOCAL: 218-825-2700 . Craguns.com Near Room 545 Room DIRECTIONS: Turn left at The Centre Office Cragun’s entrance onto CR 77. 77 77 371 Shoreline Suites Skyway Drive approximately 1 mile and 18 Shoreline Suites Basement turn left onto CR 70. The Legacy entrance will be on your right. Baxter Brainerd/Baxter GULL LAKE . Steamboat Bay Lower Lake Level Marina E L 3rd Floor North Wing 300-311 Lakeshore Rooms E Paul Bunyan Rooms V 4 321 A 1234 2nd Floor North Wing 200-215 S T T O Lower Level Lower Level Tech 3Tech 2Tech 1 A R 150-159 162-164 I R Dining Room Sun Deck S Main Middle South Poolside 230-235 Poolside Cabana Café 330-335 Poolside Luxury Meeting Room Elevator All Floors Ramp down to Pioneer Dutch Pool Level Indoor Pool y 343-345 Bear Trap Lounge Lobby 2 Levels of Hospitality Room 340 Skywa Upper Road Level Hillside Cottages 115-102 Enclosed Walkway Poolside 320-325 Poolside Poolside 221-225 Poolside sleeping rooms Shoreline Room Enclosed Walkway Lower Level Poolside Main Entrance 326-329 Door S Upper Road Level Enclosed Walkway riangle Parking T Upper Parking Lot Upper Parking Lot Lower Parking Lot Main Road MEETING ROOM LOCATIONS Lakeshore: One level directly beneath Dining Room Paul Bunyan: One level directly below Sun Deck Pioneer: Halfway down Dining Room stairs, on right Dutch: Halfway down Dining Room stairs, on left or halfway down ramp toward pool Tech Center: One level below Rooms 200-211 Tech 1: Enter Door D or E 1-800-CRAGUNS (1-800-272-4867) Tech 2: Enter Door C or D LOCAL: 218-825-2700 . Craguns.com Tech 3: Enter Door B or C Shoreline: At base of Shoreline Suite building, outdoor patio overlooking lake Room 340: Hospitality Room, Hallway of 300 level Room 371: Hallway of 300 level .
Recommended publications
  • ABSTRACT the Main Feature of a Conventional Terraced Housing Development Is Rows of Rectangular Shaped Houses with the Narrow Fa
    MAKING A RETURN ON INVESTMENT IN PASSIVE ARCHITECTURE TERRACED HOUSES DEVELOPMENT Wan Rahmah Mohd Zaki Universiti Teknologi Malaysia(UiTM) Malaysia E-mail: [email protected] Abdul Hadi Nawawi Universiti Teknologi MalaysiaQJiTM) Malaysia E-mail: [email protected] Sabarinah Sh Ahmad Universiti Teknologi MalaysiaQJiTM) Malaysia E-mail: [email protected] ABSTRACT The main feature of a conventional terraced housing development is rows of rectangular shaped houses with the narrow facade as the frontage. Consequently, this limits natural cross ventilation and daylight penetration into the middle of the houses; and cause for unnecessary energy consumption on mechanical cooling and artijicial lighting to make the living spaces comfortable for occupants. Such inconsideration is mainly attributed to the optimum configuration of houses which offers the most economic return desired by the developer. Passive Architecture (PA) design strategies can make terraced houses more conducive for occupants as well as gives reasonable returns to the developer. The idea is demonstrated on a hypothetical double storeys terraced scheme in a 2.5 acre site whereby it is transformed intofour types of PA terraced houses development. The Return on Invesfment of the PA terraced houses is ascertained for two situations, ie., (i) fwed sales price for all types of house; and (ii) added premium to PA terraced houses due to the positive unintended effects such as low density housing, etc. If critical criteria for demand and supply in housing remain constant, it is found that PA terraced housing development offers competitive returns to the developer relative to the returns for conventional terraced housing scheme. Keyworh: Orientation, Indoor Comfort and Operational Energy 1.0 INTRODUCTION 1.1 Housing and Energy The recent public awareness on sustainability calls for housing to not only serves as a basic shelter but also to be energy efficient, i.e., designed to make occupants need low operational energy.
    [Show full text]
  • Building a Safe Room Inside Your House COURTESY of NOAA/NSSL Includes Construction Plans and Cost Estimates
    FEMA 320 FIRST EDITION October 1998 COURTESY OF NASA COURTESY Taking Shelter From the Storm: Building a Safe Room Inside Your House COURTESY OF NOAA/NSSL Includes Construction Plans and Cost Estimates Federal Emergency Management Agency Mitigation Directorate 500 C Street, SW. • Washington, DC 20472 www.fema.gov Acknowledgments This booklet and the construction drawings it contains would not have been possible without the pioneering work of the Wind Engineering Research Center at Texas Tech University, the diligent efforts of the design team, and the constructive suggestions of the reviewers. Design Team Reviewers Paul Tertell, P.E. Dennis Lee Project Officer Hurricane Program Manager Program Policy and Assessment Branch Mitigation Division Mitigation Directorate FEMA Region VI FEMA Denton, Texas Washington, DC Bill Massey Clifford Oliver, CEM Hurricane Program Manager Chief, Program Policy and Assessment Branch Mitigation Division Mitigation Directorate FEMA Region IV FEMA Atlanta, Georgia Washington, DC TIm Sheckler, P.E. Dr. Ernst Kiesling, P.E. Civil Engineer Professor of Civil Engineering National Earthquake Program Office Wind Engineering Research Center Mitigation Directorate Texas Tech University FEMA Lubbock, Texas Washington, DC Dr. Kishor Mehta, P.E. Dr. Richard Peterson Director, Wind Engineering Research Center Chairman, Department of Geosciences Texas Tech University Texas Tech University Lubbock, Texas Lubbock, Texas Russell Carter, E.I.T. Larry Tanner, P.E., R.A. Research Associate Research Associate Wind Engineering Research Center Wind Engineering Research Center Texas Tech University Texas Tech University Lubbock, Texas Lubbock, Texas William Coulbourne, P.E. Richard Vognild, P.E Structural Engineer Director, Technical Services Greenhorne & O’Mara, Inc. Southern Building Code Congress International Greenbelt, Maryland Birmingham, Alabama Jay Crandell, P.E.
    [Show full text]
  • Craguns Resort Map.Pdf
    GULL LAKE . Steamboat Bay Irma’s Kitchen Dock Parking Grassy Knoll Lake Deck Lake Lake Access North Beach Lake Lake Access Wedding Site Access Access Access Lake Cabana Café Restaurant Access Hilltops Lounge Market 343-345 Lakeview Cabins Hospitality Bayview Villas Lake 684 Room 340 685 686 687 688 Access 689 Photo Opportunity Welcome to Cabin 115 resort on gull lake 1-800-CRAGUNS (1-800-272-4867) . LOCAL: 218-825-2700 . www.craguns.com DINING LAUNDRY FACILITIES MEETING ROOMS u u Lakeside Dining Room Poolside, by Room 230 u Lakeshore (Brown Signs) u Tech Center (Yellow Signs) Located at the Legacy Maps not to scale. Updated 10/17 68-2992 u Cabana Café u Shoreline Suites, One level below dining room One level below 200-211 Courses at Cragun’s: u by Room 280 u Tech 1: By Room 162, Irma’s Kitchen (Seasonal) Paul Bunyan (Blue Signs) u Audubon Room u u By Cabin 651, North of through Door E Bear Trap Lounge One level below indoor pool u Pavilion u Outdoor Pool (Summer Only) u Tech 2: Under Rooms 204-207, Legacy Grille (Seasonal) Pioneer (Black Signs) u Legacy Grille Halfway down dining room through Door D POP MACHINES Turn left at Cragun’s entrance FIREWOOD stairs, on right Tech 3: Under Rooms 200-203, u Lobby through Door C or B onto CR 77 toward Brainerd. Please call Ext. 8700 for u Dutch (Black Signs) u Drive approximately one mile Marina u Shoreline Meeting Room delivery and instructions. Halfway down dining room and turn left onto u The Centre At base of Shoreline Suite stairs, on left, OR halfway down CR 70.
    [Show full text]
  • Building Numbers, Street Addresses, Room Numbers
    www.facilities.ufl.edu BUSINESS AFFAIRS PLANNING DESIGN AND CONSTRUCTION PDC PROJECT MANAGEMENT GUIDE PMG-E14: BUILDING NUMBERS, STREET ADDRESSES, AND ROOM NUMBERS PURPOSE: To communicate guidelines and procedures for numbering facilities, establishing street addresses, and assigning space/room numbers. A. Introduction Planning Design and Construction (PDC) is responsible for numbering, tracking, and reporting facilities-related information for the University. PDC utilizes CAD/BIM technology in the data-basing of facilities information, so a meaningful numbering and CAD/BIM standard must be followed. Additionally, PDC is required to annually submit the Physical Facilities Space File to the Board of Governors and must take necessary actions to ensure the incorporation of required data elements into its operating database. Data elements are based on the Postsecondary Education Facilities Inventory and Classification Manual, 2006. B. Street Addresses A request for a street address should be made by the PDC Project Manager (PM) once a project’s physical locale has been established and before site work begins. At a minimum, the building footprint and major entry doors should be settled to establish an appropriate address. Requests for a new address will be coordinated through PDC Space Management & Analysis (SMA) staff. Upon assignment of the street address, the new address will be entered in UF-STARS for local notification to PeopleSoft, Purchasing, EH&S, and the UF community. The Alachua County E911 office will be responsible for notification to the Alachua County Call Center, USPS, major package carriers, and other external entities. New addresses outside of Alachua County should be requested by the PDC PM through PDC SMA, which will work with the appropriate local authorities.
    [Show full text]
  • Domestic Servants Personal Lives
    Explore More Domestic Servants Personal Lives In their leisure time, domestic servants likely enjoyed the same hobbies and pleasures as people in other jobs during this era. Sewing, reading, playing musical instruments, chatting over tea, or having evening gatherings in their employer’s kitchen or servants’ hall were common diversions, and may have occurred here at Lucknow. A space like the servants' hall, set aside solely for the enjoyment and rest of the servants, would have been a luxury that existed in only the wealthiest homes. Though the servants’ hall was a spot to rest and have a meal, note that the intercom, telephone, and home alarm system were in this space so a servant’s break might be frequently interrupted. For many servants in the early 20th century, Sunday would have been a typical day off to attend church, a local festival, or perhaps go to the movies. Unfortunately, domestic service workers battled the social stigma attached to their job titles, a problem which had persisted for centuries. Service was considered by some to be a disgraceful and dishonorable profession. For the most part, its workers endured a low social status in American society. A group of domestic servants, probably early 1920s. MORE ON OTHER SIDE Explore More Domestic Servants Personal Lives We don’t know for sure what it was like to live and work at Lucknow as a domestic servant, but first person accounts from people in domestic service during this era, as well as historic documents and photographs, help illustrate the experience. By the twentieth century, domestic servants had more personal freedom than they had in previous eras.
    [Show full text]
  • PLUMBING DICTIONARY Sixth Edition
    as to produce smooth threads. 2. An oil or oily preparation used as a cutting fluid espe cially a water-soluble oil (such as a mineral oil containing- a fatty oil) Cut Grooving (cut groov-ing) the process of machining away material, providing a groove into a pipe to allow for a mechani cal coupling to be installed.This process was invented by Victau - lic Corp. in 1925. Cut Grooving is designed for stanard weight- ceives or heavier wall thickness pipe. tetrafluoroethylene (tet-ra-- theseveral lower variouslyterminal, whichshaped re or decalescensecryolite (de-ca-les-cen- ming and flood consisting(cry-o-lite) of sodium-alumi earthfluo-ro-eth-yl-ene) by alternately dam a colorless, thegrooved vapors tools. from 4. anonpressure tool used by se) a decrease in temperaturea mineral nonflammable gas used in mak- metalworkers to shape material thatnum occurs fluoride. while Usedheating for soldermet- ing a stream. See STANK. or the pressure sterilizers, and - spannering heat resistantwrench and(span-ner acid re - conductsto a desired the form vapors. 5. a tooldirectly used al ingthrough copper a rangeand inalloys which when a mixed with phosphoric acid.- wrench)sistant plastics 1. one ofsuch various as teflon. tools to setthe theouter teeth air. of Sometimesaatmosphere circular or exhaust vent. See change in a structure occurs. Also used for soldering alumi forAbbr. tightening, T.F.E. or loosening,chiefly Brit.: orcalled band vapor, saw. steam,6. a tool used to degree of hazard (de-gree stench trap (stench trap) num bronze when mixed with nutsthermal and bolts.expansion 2. (water) straightenLOCAL VENT.
    [Show full text]
  • SOHO Design in the Near Future
    Rochester Institute of Technology RIT Scholar Works Theses 12-2005 SOHO design in the near future SooJung Lee Follow this and additional works at: https://scholarworks.rit.edu/theses Recommended Citation Lee, SooJung, "SOHO design in the near future" (2005). Thesis. Rochester Institute of Technology. Accessed from This Thesis is brought to you for free and open access by RIT Scholar Works. It has been accepted for inclusion in Theses by an authorized administrator of RIT Scholar Works. For more information, please contact [email protected]. Rochester Institute of Technology A thesis Submitted to the Faculty of The College of Imaging Arts and Sciences In Candidacy for the Degree of Master of Fine Arts SOHO Design in the near future By SooJung Lee Dec. 2005 Approvals Chief Advisor: David Morgan David Morgan Date Associate Advisor: Nancy Chwiecko Nancy Chwiecko Date S z/ -tJ.b Associate Advisor: Stan Rickel Stan Rickel School Chairperson: Patti Lachance Patti Lachance Date 3 -..,2,2' Ob I, SooJung Lee, hereby grant permission to the Wallace Memorial Library of RIT to reproduce my thesis in whole or in part. Any reproduction will not be for commercial use or profit. Signature SooJung Lee Date __3....:....V_6-'-/_o_6 ____ _ Special thanks to Prof. David Morgan, Prof. Stan Rickel and Prof. Nancy Chwiecko - my amazing professors who always trust and encourage me sincerity but sometimes make me confused or surprised for leading me into better way for three years. Prof. Chan hong Min and Prof. Kwanbae Kim - who introduced me about the attractive
    [Show full text]
  • Residential Bathroom Remodels Handout
    Community Development City of Visalia Building & Safety 315 E. Acequia, Visalia, CA 93291 FAX: (559) 713-4812 Residential Bathroom Remodels GENERAL NOTES 1. All work is to comply with 2016 CRC, CBC, CMC, CPC, CEC, Cal Green Code & Title 24 state energy guidelines. 2. Use low flow toilets (1.28 gallons/flush), showerheads (2 gpm), kitchen faucets (1.8 gpm) and bathroom faucet (1.5 gpm). All non-compliant fixtures shall be replaced effective January 1, 2014 per Cal Green Code. 3. Toilets are to be positioned so they have 30” width and 24” front in finish clearances. 4. Provide a 12” minimum access panel to bathtub trap connection, unless plumbing is without slip joints. For jetted tubs, access shall be provided to service motor. 5. Control valves for showers and tub-showers shall be of the pressure balance or thermostatic mixing valve type. 6. The maximum hot water temperature discharging from the bath/whirlpool tub filler is limited to 120°F by an approved device with ASSE 1070 or CSA B125.3. Water heater thermostats are not considered for meeting this provision. 7. All water fixtures must be California approved lead free. 8. Shower compartments regardless of shape, shall have a minimum finished interior of 1024 square inches & shall also be capable of encompassing a 30” circle. (CPC 408.6) 9. All permanently installed luminaries shall be high efficacy, including screw-based which shall be marked Joint Appendix 8 (JA8-2016) compliant lamps. (CEnC 150.0 (G) 10. Controls: JA8 compliant light sources must be controlled by vacancy sensor/dimmer and at least one luminaire in the bathroom, garage, laundry room and utility room must be controlled by a vacancy sensor.
    [Show full text]
  • Lehi City Broadbent Community Room Rental Agreement 128 N 100 E
    Lehi City Broadbent Community Room Rental Agreement 128 N 100 E. Lehi, UT 84043 385-201-1000 General • The renter of the facility shall be at least 18 years of age. • The Broadbent Community Room located at the Lehi Police Station is also the Emergency Operation Center (EOC) for Lehi City. If an emergency occurs that constitutes opening the EOC, your event will be canceled, and your monies refunded. • Ordinances and rulings of Lehi City Corporation (hereafter referred to as the City) as to the occupancy capacity, use, and other safety factors shall be observed at all times • The facility shall not be used for sales, or promotional purposes, or for monetary or pecuniary gain of any form or nature whatsoever. • Any sound system, video, music, etc, shall be kept at a low volume so as not to disturb others using the facility and/or neighboring residents. • Renter shall be present during the period of the reservation from set-up through clean-up • If the facility is not left clean, the renter will be assessed a $40 per hour cleaning fee to be taken out of the deposit. • Failure to comply with any of the terms of the Renal Agreement shall cause the individual and/or group to forfeit the privilege to reserve the facility for one year. Rental Fees Rental fees for the facility shall be assessed as specified in the Lehi City Consolidated Fee Schedule. • No fees shall be pro-rated for a portion of an hour. Security Deposit • The purpose of the security deposit is to ensure proper clean-up and care of facility.
    [Show full text]
  • 2020 Mandatory Design Standards for Multifamily Housing Part A
    MFA 2020 Mandatory Design Standards for Multifamily Housing Part A The following Design Standards, including the MFA 2020 Submission Instructions for Preliminary Architectural Documentation for Multifamily Housing Applications, contained herein as Part B, represent the minimum requirements for New Mexico Mortgage Finance Authority (MFA) financed rental housing and are herewith incorporated by reference into MFA’s 2020 Qualified Allocation Plan (QAP). Capitalized terms are defined either herein or in the QAP. MFA values excellence in design because well designed housing meets the needs of tenants, attracts market tenants and promotes community acceptance of housing financed by MFA. All Projects shall meet or exceed each of these standards, as well as the minimum requirements of all applicable building codes (hereinafter referred to as “Code”), regulations, and local zoning ordinances. In addition, Projects shall meet Americans with Disabilities Act (ADA) and Fair Housing Act (FHA) requirements as applicable. Depending on the funding sources and other partners’ requirements, the Project may also be subject to Uniform Federal Accessibility Standards (UFAS) requirements. Projects receiving HOME funding must meet the property standards of 24 CFR 92.251. Projects receiving National Housing Trust Funds must meet the property standards of 24 CFR 93.301 (f) (1) and (2).The development team is responsible to know and meet all accessibility requirements for their Project. MFA will not be reviewing submissions with the intent to identify compliance with these various laws, codes, and ordinances governing the design of the projects. Should we find a discrepancy in a design that does not meet a law, code, or ordinance, we will, as a courtesy, inform the designer of our findings.
    [Show full text]
  • Pittock Mansion Discovery Program
    Photo courtesy of Michael Henley Michael of courtesy Photo PITTOCK MANSION DISCOVERY PROGRAM DISCOVERY MANSION PITTOCK Location #20 - Laundry Room Look through the glass door to the laundry room. What tools do you see for doing the laundry? Looking at the tools, why do you think it took longer to do laundry in 1914 than today? Pittock Mansion was finished in 1914 and was the home of Henry and Georgiana Pittock and their family. Henry and Georgiana both worked to build Portland into the community we know. Henry was the founder of The Daily Oregonian newspaper. Georgiana cared for their family, managed their household, and worked raising money for charities. Both helped organize the Rose Festival. Instructions for use: Start at the location number assigned to your group and continue numerically. You will explore 20 stations on 3 floors of the mansion. Follow the maps and instructions in this booklet as you go. Expect to spend about 2-3 minutes per location. As you explore, think about how Henry Pittock life in Portland has changed over time! Georgiana Pittock Basement 20 Location #19 - Child’s Room Think about whether these toys are like toys today. Can you name a toy that kids play with today that kids in 1914 did not have? First Floor 2 3 1 4 8 7 5 6 Location #1 - The Library This room is where the Pittock family gathered in the evening. What might the family do for fun in this room? Oregon did not have any radio stations until 1922, and TV and computers were not yet invented in 1914, but the Pittocks could have played with stereoscopes like the ones in this room.
    [Show full text]
  • Multifamily Residential Unit and Hotel Room
    PROFILE2013 A Supplemental Factsheet - Updated Residential and Hotel Conversion Factors MULTIFAMILY RESIDENTIAL UNIT AND HOTEL ROOM CONVERSION FACTORS As a complimentary piece to Profile 2013, the Planning Multifamily Residential Units Division periodically releases supplemental factsheets on highly valued statistical elements and trends. A multifamily residential unit to residential GFA This supplemental factsheet focuses on multifamily conversion factor relies on the countywide average residential unit and hotel room Gross Floor Area (GFA) GFA of a multifamily residential unit. For an individual conversion factors. project this can be defined as the total residential GFA divided by the number of residential units. Taking the GFA is defined as the sum of the area of the horizontal mean of these individual project averages produces an surface of several floors of a building measured from average GFA of a multifamily residential unit for the the exterior faces of exterior walls. In various planning sample. and zoning processes, a conversion factor is needed to convert between the estimated number of residential Residential GFA excludes any retail space but includes units or hotel rooms and/or the estimated residential common building spaces such as hallways, lobbies, or hotel GFA of the project. These conversion factors and amenity rooms. Figure 1 shows the range of are primarily used in generating estimates of existing average GFA values of multifamily residential units by and forecasted development. completion year for a selected sample of individual multifamily projects. The green dot represents the Using site plan summaries and various county data mean of all the individual project averages for each sources, a list of recent and proposed multifamily completion year.
    [Show full text]