Microwave Measurements of Hall Mobilities in Semiconductors

Total Page:16

File Type:pdf, Size:1020Kb

Microwave Measurements of Hall Mobilities in Semiconductors MICROWAVE MEASUREMENTS OF HALL MOBILITIES IN SEMICONDUCTORS by Yuiehiro Nishina A Dissertation Submitted to the Graduate Faculty in Partial Fulfillment of The Requirements for the Degree of DOCTOR OF PHILOSOPHY Major Subject: Physics Approved: Signature was redacted for privacy. In Chargé of Major Work Signature was redacted for privacy. /Head of Major Department / Signature was redacted for privacy. Iowa State University Of Science and Technology Ames, Iowa 1960 il TABLE OF CONTENTS Page ABSTRACT vi I. INTRODUCTION 1 A. Hall Effect 1 B. Hall Effect In High Frequency Field .... 4 C. Previous Work on Microwave Hall Effect Measurement 6 D. Purpose of This Investigation 8 II. THEORY 9 A. Conductivity Tensor 9 B. Conductivity Tensor and the Hall Effect . 12 C. Principle of Measurement 15 1. Microwave degenerate cavity 15 2. Microwave power relationship 19 III. EXPERIMENTAL PROCEDURE 26 A. Microwave Measurement 26 1. Microwave cavity £6 2. Sample preparation 29 3. Temperature measurement and control . 31 4. Microwave measurement 34 B . D . C. Measurement 38 1. Cryostat and sample preparation .... 38 2. Electrical measurement 41 IV. EXPERIMENTAL RESULTS 45 A. N-type Germanium 45 1. Room temperature measurement 45 2. Low temperature measurement 52 B . P-type Germanium 57 iii Page V. DISCUSSION 65 A. Errors 65 1. Microwave measurement 65 c- D-C. measurement 68 B. Effect of Depolarization 70 C. Effect of Cyclotron Resonance 73 D - Future v/ork 76 VI. CONCLUSION 78 VII. REFERENCES 80 VIII. ACKNOWLEDGMENTS 83 IX. APPENDIX 84 iv LIST OF TABLES Page /Pjj i Table 1. Magnetic field dependence of VPII/-= i 1_ + R_| I for n-type germanium (GK-ô) at room temperature 85 Table 'c. Geometrical dependence of l^~ i i 1 — VP1 I 1 + R I Bo for n-type germanium (GN-6) at room temperature 86 Table 3. Magnetic field dependence of for n-type germanium (GK-5) 87 Table 4. Microwave Hall mobility of n-type germanium (GN-5) in low temperatures. ... 89 Taole 5. D.C. electrical measurement of n-type germanium ( GN-5-b) 90 /p7 Tacle 6. Magnetic field dependence of l~ for p-type germanium (GP-1) 91 Table 7. Microwave Hall mobility of p-type germanium (GP-1) in low temperatures. ... 93 Table 8. Magnetic field dependence of microwave Hall mobility in p-type germanium (GP-1) .... 94 Table 9. D.C. electrical measurement of p-type germanium ( GP-1-1) 95 Table 10. Magnetic field dependence of D.C. R^• 0~(B0) of p-type germanium ( GP-1-1) 96 V LIST OF FIGURES Page Fig. 1. Principle of microwave Hall mobility measurement 16 Fig. 2. Cavity construction for low temperature measurement 27 Fig. 3. Details of sample mounting on microwave cavity 30 Fig. 4. Schematic diagram of temperature measurement and control 33 Fig. 5. Schematic diagram of microwave circuit ... 35 Fig. 6. Cryostat for D.C. measurement 39 Fig. 7. Sample holder for D.C. measurement 40 Fig. 8. Notations for D.C. electrical measurement. 42 /Pc 1 Fig. 9. Magnetic field dependence of Ljz. V r j Jl + n| for n-type germanium at room temperature . 49 /pp i i Fig. 10. Geometrical dependence of . „• — V^i jl + K| ti0 for n-type germanium at room temperature . 53 IpZ Fig. 11. Magnetic field dependence of ^ for n-type germanium 4 f 55 Fig. 12. Hall mobility of n-type germanium vs. temperature 56 Fig. 13. Magnetic field dependence of for p-type germanium .4- 57 Fig. 14. Hall mobility of p-type germanium vs. temperature 61 Fig. 15. Hall mobility of p-type germanium vs. magnetic field 62 Fig. 16. Effect of cyclotron resonance on microwave power relationship 75 vi ABSTRACT The Hall mobilities of germanium single crystals were measured with a microwave frequency of 9000 Mc/sec over the temperature range 30°K to 300°K. A rectangular sample occu­ pied the central part of a wall of a rectangular cavity, which was doubly degenerate in the TE^01 mode and in the TE011 mode at a single resonance microwave frequency. The external mag­ netic field and the microwave field associated with one of the two modes gave rise to the other mode of oscillation, owing to excitation by the microwave Hall field. The theo­ retical analysis was verified by measurements on an n-type sample having a room temperature resistivity of 0.40 ohm cm. The measured Hall mobility at microwave frequencies (with a size correction) was compared with the D.C. Hall mobility between 30°K and 300°K. The maximum discrepancy was 15%. The estimated experimental error in the microwave measurement was 16/&. The magnetic field dependence of the microwave Hall mobility in a p-type sample, having a room temperature resis­ tivity of 0.77 ohm cm, was in qualitative agreement with the D.C. results obtained oy Willardson et al. 1 I. INTRODUCTION A. Hall Effect In the study of electronic structure of solids, particu­ larly in conductors and semiconductors, the Hall effect con­ tributes to our knowledge of the sign and concentration of the free charge carriers. The effect was found by E. H. Hall in 1879, and it can be explained in terms of the definition of the Hall coefficient R^ If a rectangular coordinate is designated along each axial direction of a rectangular con­ ductor, the Hall coefficient R^is expressed as Rw& ' (1'1) where Jx = trie static current density in the x direction, Bz = the static magnetic field of induction, Ey = tne static electric field induced by the Hall effect with no current in this direction, i.e. Jy = 0. All quantities are given in MKS units. Another quantity of fundamental importance is the Hall mobility, u, defined as u = F^r , (1.2) where cr is the D.C. conductivity. The physical implications of the Hall coefficient and the Hall mobility in semiconductors can be clarified if the analysis is made by means of Boltzmann1s transport equation + V-*f + ' (1*3) 1 MIc - where f is the distribution function of the carriers and ["^-£*1 is the rate of change of f due to the scattering of J° 2 f the carriers. For a steady state one has =0. As ex­ plained by Wilson (1, p. £09), when the static electric and magnetic fields are applied in a semiconductor where the existence of a relaxation time T is assumed, Equation 1.3 becomes, for the isothermal case, f - t•of __ e [E + V x B]-7 kf . (1.4) Here fQ is the value of f when there is no external force on the carriers. If f is expressed as f = f0 - "v • <f> (£ ) , (1.5) —> and if the terms of higher order in V are neglected, Equation k> 2 1.4 can be solved for spherical energy surfaces ( 6 = A_K_), provided SL. <f> ( € ) = e(mE + fx B j. (1.6) The use of Equations 1.5 with 1.6 gives the relationship be­ tween the current density and the applied field. If Maxwell-BoItzmann distribution is assumed for the carriers, one obtains, for B 1 , m CT= Ne%T> (1.7) m ' Rh - h • (1-8) U - RhCT - r! <Xy ' (1,9) • eo 3 wnere = —j= J g x^ exp x dx , (1.10) 3(W J 0 X = r£=r , (1.11) A0 1 and 3 yOÛ î (an)fc / N = / 6 ^ fo dC (1.12) " 2 7f*k3 y Vn'0 = density of carriers. Equation 1.10 Implies that <g7 is the averspe value of g over the Boltzmann distribution. If it is assumed that p r = T0(t)£ , (i.i3) Equation 1.9 reduces to i K-. T i -P I l ^ x /T"«/ 5 u = im R*• o0 U0T) NF + P)/N|) • (1-14) Hence the value of p for a scattering mechanism would be exhibited in the temperature dependence of the Hall mobility. Seitz (%) derived the temperature dependence of the mobil­ ity for lattice scattering. The analysis indicated thst the mobility should change as T In the low temper­ ature region the scattering by ionized impurity atoms be­ comes predominant. According to the Conwell and V/eisskopf formula (3), the mobility shows the T3//^ dependence. 4 In case of germanium, however, the temperature dependences of the mobilities in the lattice scattering range are T_1'for electrons and T ' for holes as they were found by Morin et al. (4) and by Prince (5), respectively. B. Hall Effect in High Frequency Field In the previous discussion all external fields applied in the solids were treated as static and the solution to the Boltzmann's Equation 1.3 was true for = 0. If the ex­ ternal field changes in a time comparable to relaxation time, the charge carriers are no longer in a steady state. Particularly, if the external fields change sinusoidally the deviation in f from f0 also has to change in the same manner. Hence one obtains -|I = jo> (f - f0) , (1.15) where co is the angular frequency of the external fields. Then the solution to Equation 1.3 can be obtained in the same manner as in the case of steady state except is replaced by ^ . When an electromagnetic wave is propagating in the Z direction along which a static magnetic field of induction B is applied, the solution to Equation 1.3 with the assumptions made in the previous discussion gives *This substitution was used conveniently in the analysis by Donovan (6). Jx " ¥ fE* <rrw> + Ey<(rrwf>i B} (1"16) y m- (- Ex<C(l + 7»^) B * Ey C + (1'17) where the higher powers of ^ ^ ^^ ^ B are neglected.
Recommended publications
  • The Absolute Measurement of Capacity
    THE ABSOLUTE MEASUREMENT OF CAPACITY. By Edwakd B. Rosa and Frederick "W. Grover. 1. The Method Employed. The usual method of determining the capacity of a condenser in electromagnetic measure is Maxwell's bridge method, using a tuning fork or a rotating commutator to charge and discharge the condenser, Fig. 1. which is placed in the fourth arm of a Wheatstone bridge. This is a null method, is adapted to measuring large and small capacities equally well, and requires an accurate knowledge only of a resistance and the rate of the fork or commutator. 153 154 BULLETIN OF THE BUREAU OF STANDARDS. [vol.1, no. 2. The formula for the capacity C of the condenser as given by J. J Thomson, is as follows: * i_L a (a+h+d){a+c+g) 0= (1) ncd \} +c{a+l+d))\} + d(a+c+g)) in which <z, c, and d are the resistances of three arms of a Wheatstone bridge, b and g are battery and galvanometer resistances, respectively, and n is the number of times the condenser is charged and discharged per second. When the vibrating arm P touches Q the condenser is charged, and when it touches P it is short circuited and discharged. When Pis not touching Q the arm BD of the bridge is interrupted and a current flows from D to C through the galvanometer; when P touches Q the condenser is charged by a current coming partly through c and partly through g from C to D. Thus the current through the galvanometer is alternately in opposite directions, and when these opposing currents balance each other there is no deflection of the gal- vanometer.
    [Show full text]
  • An Analysis of Inertial Seisometer-Galvanometer
    NBSIR 76-1089 An Analysis of Inertial Seisdmeter-Galvanorneter Combinations D. P. Johnson and H. Matheson Mechanics Division Institute for Basic Standards National Bureau of Standards Washington, D. C. 20234 June 1976 Final U. S. DEPARTMENT OF COMMERCE NATIONAL BUREAU Of STANDARDS • TABLE OF CONTENTS Page SECTION 1 INTRODUCTION ^ 1 . 1 Background 1.2 Scope ^ 1.3 Introductory Details 2 ELECTROMAGNETIC SECTION 2 GENERAL EQUATIONS OF MOTION OF AN INERTIAL SEISMOMETER 3 2.1 Dynaniical Theory 2 2.1.1 Mechanics ^ 2.1.2 Electrodynamics 5 2.2 Choice of Coordinates ^ 2.2.1 The Coordinate of Earth Motion 7 2.2.2 The Coordinate of Bob Motion 7 2.2.3 The Electrical Coordinate 7 2.2.4 The Magnetic Coordinate 3 2.3 Condition of Constraint: Riagnet 3 2.4 The Lagrangian Function • 2.4.1 Mechanical Kinetic Energy 10 2.4.2 Electrokinetic and Electro- potential Energy H 2.4.3 Gravitational Potential Energy 12 2.4.4 Mechanical Potential Energy 13 2.5 Tne General Equations of Motion i4 2.6 The Linearized Equations of Motion 2.7 Philosophical Notes and Interpretations 18 2.8 Extension to Two Coil Systems 18 2.8.1 General 2.8.2 Equations of Motion -^9 2.8.3 Reciprocity Calibration Using the Basic Instrument 21 2.8.4 Reciprocity Calibration Using Auxiliary Calibrating Coils . 23 2.9 Application to Other Electromagnetic Transducers - SECTION 3 RESPONSE CFARACTERISTICS OF A SEISMOMETER WITH A- RESISTIVE LOAD 3.1 Introduction 3.2 Seismometer with Resistive Load II TABLE GF CONTENTS Page 3.2.1 Steady State Response 27 3.
    [Show full text]
  • Electrical & Electronics Measurement Laboratory Manual
    DEPT. OF I&E ENGG. DR, M, C. Tripathy CET, BPUT Electrical & Electronics Measurement Laboratory Manual By Dr. Madhab Chandra Tripathy Assistant Professor DEPARTMENT OF INSTRUMENTAION AND ELECTRONICS ENGINEERING COLLEGE OF ENGINEERING AND TECHNOLOGY BHUBANESWAR-751003 PAGE 1 | EXPT - 1 ELECTRICAL &ELECTRONICS MEASUREMENT LAB DEPT. OF I&E ENGG. DR, M, C. Tripathy CET, BPUT List of Experiments PCEE7204 Electrical and Electronics Measurement Lab Select any 8 experiments from the list of 10 experiments 1. Measurement of Low Resistance by Kelvin’s Double Bridge Method. 2. Measurement of Self Inductance and Capacitance using Bridges. 3. Study of Galvanometer and Determination of Sensitivity and Galvanometer Constants. 4. Calibration of Voltmeters and Ammeters using Potentiometers. 5. Testing of Energy meters (Single phase type). 6. Measurement of Iron Loss from B-H Curve by using CRO. 7. Measurement of R, L, and C using Q-meter. 8. Measurement of Power in a single phase circuit by using CTs and PTs. 9. Measurement of Power and Power Factor in a three phase AC circuit by two-wattmeter method. 10. Study of Spectrum Analyzers. PAGE 2 | EXPT - 1 ELECTRICAL &ELECTRONICS MEASUREMENT LAB DEPT. OF I&E ENGG. DR, M, C. Tripathy CET, BPUT DO’S AND DON’TS IN THE LAB DO’S:- 1. Students should carry observation notes and records completed in all aspects. 2. Correct specifications of the equipment have to be mentioned in the circuit diagram. 3. Students should be aware of the operation of equipments. 4. Students should take care of the laboratory equipments/ Instruments. 5. After completing the connections, students should get the circuits verified by the Lab Instructor.
    [Show full text]
  • Manual S/N Prefix 11
    HP Archive This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web ! On-line curator: Glenn Robb This document is for FREE distribution only! OPERATING AND SERVICING MANUAL FOR MODEL 475B TUNABLE BOLOMETER MOUNT Serial 11 and Above Copyright 1956 by Hewlett-Packard Company The information contained in this booklet is intended for the operation and main· tenance oC Hewlett-Packard equipment and is not to be used otherwise or reproduced without the written consent of the Hewlett­ Packard Company. HEWLETT-PACKARD COMPANY 275 PAGE MILL ROAD, PALO ALTO, CALIFORNIA, U. S. A. 475BOOl-1 SPECIFICATIONS FREQUENCY RANGE: Approximately 1000 - 4000 MC (varies with SWR and phase of source and value of bolometer load.) POWER RANGE: 0.1 to 10 milliwatts (with -hp- Model 430C Microwave Power Meter.) FITTINGS: Input Connector - Type N female (UG 23/U). Output Connector (bolometer dc connec­ tion) - Type BNC (UG 89/U). Type N Male Connector (UG 21/U) sup­ plied to replace bolometer connector so that mount may be used as a conven­ tional double -stub transformer. POWER SENSITIVE ELEMENT: Selected 1/100 ampere instrument fuse. Sperry 821 or Narda N821 Barretter. Western Electric Type D166382 Ther­ mistor. OVERALL DIMENSIONS: 1811 long x 7-3/8" wide x 3-5/811 deep. WEIGHT: 8 pounds. ...... ...... Pl ::l P. Pl 0-' o <: Cil >+>­ -J lJ1 lJj o o ...... ......I • OPERATING INSTRUC TIONS INSPECTION This instrument has been thoroughly tested and inspected before being shipped and is ready for use when received. After the instrument is unpacked, it should be carefully inspected for any damage received in transit.
    [Show full text]
  • (Ohmmeter). Aims: • Calibrating of a Sensitive Galvanometer for Measuring a Resistance
    Exp ( ) Calibrating of a sensitive galvanometer for measuring a resistance (Ohmmeter). Aims: • Calibrating of a sensitive galvanometer for measuring a resistance. The theory When a galvanometer is used as an ohmmeter for measuring an ohmic resistance R, the deviation angle θ of the galvanometer’s coil is directly proportional to the flowing current through the coil and inversely proportional to the value of the resistance. The deviation will reach to the maximum end when the resistance equals to zero or the current has the maximum value. For this reason, the scale will be divide by inversely way in comparison with the ammeter and the voltmeter. The original circuit as shown in Fig(1) consists of a dry cell(E) , rheostat and ammeter (A) are connected in series with small resistor s has the range of 1 omega. The two terminals of “s” are connected in parallel to another combination includes a sensitive galvanometer “G” which has internal resistance “r” and a resistors box “R”, this combination is called the measuring circuit. When the value of R equals zero, and by moving the rheostat in the original circuit, it is possible to set the flowing electric current in measuring the circuit as a maximum value od deviation in the galvanometer. By assigning different values of R, the deviation θ is decreasing with increasing the value of R or by another meaning when the flowing current through the galvanometer decreases. Therefore, the current through the galvanometer is inversely proportional to the value of R according the following Figure 1: Ohmmeter Circuit diagram equation; V=I(R+r) R=V/I-r or R=V/θ-r 1 | P a g e This is a straight-line equation between R and (1/θ) as shown in Fig(2).
    [Show full text]
  • Ballastic Galvanometer This Is a Sophisticated Instrument. This
    Ballastic galvanometer This is a sophisticated instrument. This works on the principle of PMMC meter. The only difference is the type of suspension is used for this meter. Lamp and glass scale method is used to obtain the deflection. A small mirror is attached to the moving system. Phosphorous bronze wire is used for suspension. When the D.C. voltage is applied to the terminals of moving coil, current flows through it. When a current carrying coil kept in the magnetic field, produced by permanent magnet, it experiences a force. The coil deflects and mirror deflects. The light spot on the glass scale also move. This deflection is proportional to the current through the coil. Q i = , Q = it = idt t Q , deflection Charge Fig 2.27 Ballastic galvanometer Measurements of flux and flux density (Method of reversal) D.C. voltage is applied to the electromagnet through a variable resistance R1 and a reversing switch. The voltage applied to the toroid can be reversed by changing the switch from position 2 to position ‘1’. Let the switch be in position ‘2’ initially. A constant current flows through the toroid and a constant flux is established in the core of the magnet. A search coil of few turns is provided on the toroid. The B.G. is connected to the search coil through a current limiting resistance. When it is required to measure the flux, the switch is changed from position ‘2’ to position ‘1’. Hence the flux reduced to zero and it starts increasing in the reverse direction. The flux goes from + to - , in time ‘t’ second.
    [Show full text]
  • 802314-3) Laboratory Manual (Fall 2016: Term 1, 1437/1438H
    اﳌﻤﻠﻜﺔ اﻟﻌﺮﺑﻴﺔ اﻟﺴﻌﻮدﻳﺔ KINGDOM OF SAUDI ARABIA Ministry of Higher Education وزارة اﻟﺘﻌﻠﻴﻢ اﻟﻌﺎﱄ - ﺟﺎﻣﻌﺔ أم اﻟﻘﺮى Umm Al-Qura University ﻛﻠﻴﺔ اﳍﻨﺪﺳﺔ و اﻟﻌﻤﺎرة اﻹﺳﻼﻣﻴﺔ College of Engineering and Islamic Architecture ﻗﺴﻢ اﳍﻨﺪﺳﺔ اﻟﻜﻬﺮ?ﺋﻴﺔ Electrical Engineering Department ELECTRICAL AND ELECTRONIC MEASUREMENTS (802314-3) Laboratory Manual (Fall 2016: Term 1, 1437/1438H) Prepared by: Dr. Makbul Anwari Approved by: Control Sequence Committee Table of Contents Page 1. Introduction 3 2. Laboratory Safety 3 3. Lab Report 5 4. Experiment # 1: 6 5. Experiment # 2: 11 6. Experiment # 3: 19 7. Experiment # 4: 25 8. Experiment # 5: 29 2 Introduction This manual has been prepared for use in the course 802314-3, Electrical and Electronic Measurements. The laboratory exercises are devised is such a way as to reinforce the concepts taught in the lectures. Before performing the experiments the student must be aware of the basic laboratory safety rules for minimizing any potential dangers. The students must complete and submit the pre-lab report of each exercise before performing the experiment. The objective of the experiment must be kept in mind throughout the lab experiment. Laboratory Safety: ∑ Safety in the electrical engineering laboratory, as everywhere else, is a matter of the knowledge of potential hazards, following safety regulations and precautions, and common sense. ∑ Observing safety precautions is important due to pronounced hazards in any electrical engineering laboratory. ∑ All the UQU Electrical Engineering Students, Teaching Assistants, Lab Engineers, and Lab technicians are required to be familiar with the LABORATORY SAFETY GUIDELINES FOR THE UQU ELECTRICAL ENGINEERING UNDERGRADUATE LAB AREAS published on the department web-page.
    [Show full text]
  • TI S4 Audio Frequency Test Apparatus.Pdf
    TECHNICAL INSTRUCTION S.4 Audio-frequency Test Apparatus BRITISH BROADCASTING , CORPORATION ENGINEERING DlVlSlON - ', : . iv- TECHNICAL INSTRUCTION S.4 Third Issue 1966 instruction S.4 Page reissued May. 1966 CONTENTS Page Section I . Amplifier Detector AD14 . 1.1 Section 2 . Variable Attenuator AT119 . Section 3 . Wheatstone Bridge BG/I . Section 4 . Calibration IJnit CALI1 . Section 5. Harmonic Routine Tester FHP/3 . Section 6 . 0.B. Testing Unit 0BT/2 . Section . 7 . Fixed-frequency Oscillators OS/9. OS/ 10. OS/ IOA . Section 8 . Variable-frequency Oscillators TS/5 .. TS/7 . 1' . TS/8 . TS/9 . TS/ 10. TS/ 1OP . Section 9 . Portable Oscillators PTS/9 . PTS/IO . ... PTS/12 . PTS/13 . PTS/l5 .... PTS/l6 .... Appendix . The Zero Phase-shift Oscillator with Wien-bridge Control Section 10. Transmission Measuring Set TM/I . Section 1 I . Peak Programme Meter Amplifiers PPM/2 ..... PPM/6 . TPM/3 . Section 12 Valve Test Panels VT/4. VT/5 "d . Section 13. Microphone Cable Tester MCT/I . Section 14 . Aural Sensitivity Networks ASN/3. ASN/4 Section 15 . Portable Amplifier Detector PAD19 . Section 16. Portable Intermodulation Tester PIT11 Section 17. A.C. Test Meters ATM/I. ATM/IP . Section 18 . Routine Line Testers RLT/I. RLT/IP . Section 19. Standard Level Panel SLP/3 . Section 20 . A.C. Test Bay AC/55 . Section 21 . Fixed-frequency Oscillators: OS2 Series Standard Level Meter ME1611 . INSTRUCTION S.4 Page reissued May 1966 ... CIRCUIT DIAGRAMS AT END Fig. 1. Amplifier Detector AD14 Fig. 2. Wheatstone Bridge BG/1 Fig. 3. Harmonic Routine Tester FHP/3 Fig. 4. Oscillator OS/9 Fig.
    [Show full text]
  • A History of Impedance Measurements
    A History of Impedance Measurements by Henry P. Hall Preface 2 Scope 2 Acknowledgements 2 Part I. The Early Experimenters 1775-1915 3 1.1 Earliest Measurements, Dc Resistance 3 1.2 Dc to Ac, Capacitance and Inductance Measurements 6 1.3 An Abundance of Bridges 10 References, Part I 14 Part II. The First Commercial Instruments 1900-1945 16 2.1 Comment: Putting it All Together 16 2.2 Early Dc Bridges 16 2.3 Other Early Dc Instruments 20 2.4 Early Ac Bridges 21 2.5 Other Early Ac Instruments 25 References Part II 26 Part III. Electronics Comes of Age 1946-1965 28 3.1 Comment: The Post-War Boom 28 3.2 General Purpose, “RLC” or “Universal” Bridges 28 3.3 Dc Bridges 30 3.4 Precision Ac Bridges: The Transformer Ratio-Arm Bridge 32 3.5 RF Bridges 37 3.6 Special Purpose Bridges 38 3,7 Impedance Meters 39 3.8 Impedance Comparators 40 3.9 Electronics in Instruments 42 References Part III 44 Part IV. The Digital Era 1966-Present 47 4.1 Comment: Measurements in the Digital Age 47 4.2 Digital Dc Meters 47 4.3 Ac Digital Meters 48 4.4 Automatic Ac Bridges 50 4.5 Computer-Bridge Systems 52 4.6 Computers in Meters and Bridges 52 4.7 Computing Impedance Meters 53 4.8 Instruments in Use Today 55 4.9 A Long Way from Ohm 57 References Part IV 59 Appendices: A. A Transformer Equivalent Circuit 60 B. LRC or Universal Bridges 61 C. Microprocessor-Base Impedance Meters 62 A HISTORY OF IMPEDANCE MEASUREMENTS PART I.
    [Show full text]
  • Complex Circuits Paige Cooper, Adriana Knight, Liz Larsen, Ryan Olesen Meters
    Complex Circuits Paige Cooper, Adriana Knight, Liz Larsen, Ryan Olesen Meters Voltmeters are devices that measure voltage → use parallel connections Ammeters are devices that measure current → use series connections If charges only flow in one direction, then the circuit is considered a Direct Current. In this unit we are talking about meters that utilize DCs. Parallel Connection - A parallel circuit has more than one resistor (anything that uses electricity to do work) and gets its name from having multiple (parallel) paths to move along . Charges can move through any of several paths. - More current flows through the smaller resistance. (More charges take the easiest path.) - As the charges move through the resistors they do work on the resistor and as a result, they lose electrical energy. - By the time each charge makes it back to the battery, it has lost all the electrical energy given to it by the battery. - a charge can only do as much work as was done on it by the battery Series Connection In a series connection the currents all go through the same series of components in the circuit. Because of this, all of the components carry the same current. There is only one path in which the current may go. Analog Meters : Galvanometers ● Analog: Needles that swivel and point at number on the scale ● Digital meters: numerical readouts ● Current flows through the Galvanometers and produces a proportional needle deflection ● Current sensitivity→ It is deflection produced in the galvanometer per unit current flowing through it, the maximum current that the instrument can measure. ● The internal resistance of galvanometers are close to zero.
    [Show full text]
  • The OHM Meter an Ohmmeter Is an Electrical Instrument That Measures
    The OHM meter An ohmmeter is an electrical instrument that measures electrical resistance, the opposition to an electric current. Micro-ohmmeters (microhmmeter or microohmmeter) make low resistance measurements. Megohmmeters (aka megaohmmeter or in the case of a trademarked device Megger) measure large values of resistance. The unit of measurement for resistance is ohms (). The original design of an ohmmeter provided a small battery to apply a voltage to a resistance. It uses a galvanometer to measure the electric current through the resistance. The scale of the galvanometer was marked in ohms, because the fixed voltage from the battery assured that as resistance is decreased, the current through the meter would increase. Ohmmeters form circuits by themselves, therefore they cannot be used within an assembled circuit. A more accurate type of ohmmeter has an electronic circuit that passes a constant current (I) through the resistance, and another circuit that measures the voltage (V) across the resistance. According to the following equation, derived from Ohm's Law, the value of the resistance (R) is given by: On the ohms ranges of a normal multimeter the unknown resistance is connected in series with a battery and the meter and the scale reads backwards. A variable resistor is included in the circuit so that the meter can be adjusted to read full scale with the test terminals shorted (Fig 1). In the shunt ohmmeter a battery and variable resistor are connected across a milli ammeter and the resistor is adjusted so that the meter reads full scale with the test terminals are unconnected (Fig.2).
    [Show full text]
  • Megohmmeter Model 1000N (Catalog# 185.100) Repair and Calibration Manual
    Rev. 8 3/04 MEGOHMMETER MODEL 1000N (CATALOG# 185.100) REPAIR AND CALIBRATION MANUAL MODEL 1000N REPAIR AND CALIBRATION MANUAL CAT. #185.100 TABLE OF CONTENTS Repair and Technical Services....................................................................................... 3 Introduction..................................................................................................................... 4 Specific Features............................................................................................................ 4 Principal Characteristics ................................................................................................. 4 Specifications ..................................................................................................................6 Operation........................................................................................................................ 7 Calibration .................................................................................................................... 11 Taking the Instrument Apart ......................................................................................... 14 Troubleshooting............................................................................................................ 17 Summary of Malfunctions ............................................................................................. 20 Component Parts List................................................................................................... 21 Mechanical
    [Show full text]