Lithonia PT2U MV Parabolic Spec Sheet
Total Page:16
File Type:pdf, Size:1020Kb
FEATURES & SPECIFICATIONS INTENDED USE — Designed for use in open area applications and electronic offices where optical control, visual comfort and light cut-off are important. Attributes: Design optimized for use with T8 lamps and low-profile electronic ballasts. Aluminum louvers utilize the latest developments in louver finishing for minimized louver iridescence. CONSTRUCTION — Black reveal provides floating louver appearance, conceals optional air-supply slots. Square corner end plates improve strength and durability. Integral T-bar safety clips hold fixture to T-bar securely; no fasteners required. Heavy-gauge hinges die-formed for maximum strength; spring action latches concealed in black reveal. Parabolics Housing formed from cold-rolled steel. Louver formed from anodized aluminum. No asbestos used in this product. Finish: Five-stage iron-phosphate pretreatment ensures superior paint adhesion. Painted parts finished with high-gloss, baked white enamel. ELECTRICAL — Electronic ballasts are sound rated A. Full light output, reduced energy. Less than 10% THD multi-volt operation (120-277). Fixture conforms to UL1570 and is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required temperatures. LISTINGS — UL Listed (Standard). WARRANTY — 2-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx NOTE: Actual performance may differ as a result of end-user environment and application. Specifications subject to change without notice. Specifications PT2U 2x2: 9-cell Specifications PT3 2x4: 18-cell Length: 24 (61.0) Length: 48 (122.0) Width: 24 (61.0) Width: 24 (61.0) Depth: 4-1/2 (11.4) Depth: 4-1/2 (11.4) Weight: 32 lbs (14.5 kg) Weight: 32 lbs (14.5 kg) All dimensions are inches (centimeters) unless otherwise indicated. ORDERING INFORMATION Catalog # of # of Ballast # of Lamp Lamp Pallet Number UPC Description Lamps Cells Wattage Voltage type Ballasts type Pre-wired included qty. PT3 MV 745975079155 2x4 recessed, static 3 18 32 120-277 Electronic, instant start 1 N/A N N 20 PT3L MV 745975079421 2x4 recessed, static 3 18 32 120-277 Electronic, instant start 1 3500 K N Y 20 PT3LW MV 745975079360 2x4 recessed, static 3 18 32 120-277 Electronic, instant start 1 3500 K Y Y 20 PT3 2MV 745975118373 2x4 recessed, static 3 18 32 120-277 Electronic, instant start 2 N/A N N 20 PT3A MV 745975079513 2x4 recessed, air 3 18 32 120-277 Electronic, instant start 1 N/A N N 20 PT2U MV 745975079247 2x2 recessed, static 2 9 32-U lamp 120-277 Electronic, instant start 1 N/A N N 40 PT2UA MV 745975490417 2x2 recessed, air 2 9 32-U lamp 120-277 Electronic, instant start 1 N/A N N 40 PT2UALW MV 745975466580 2x2 recessed, air 2 9 32-U lamp 120-277 Electronic, instant start 1 3500 K Y Y 40 PT3L41 MV 745976877781 2x4 recessed, static 3 18 32 120-277 Electronic, instant start 1 4100 K N Y 20 PT3L41W MV 745975728473 2x4 recessed, static 3 18 32 120-277 Electronic, instant start 1 4100 K Y Y 20 FLUORESCENT PARABOLIC Parabolics 2'x4' and 2'x2' MOUNTING DATA DIMENSIONS All dimensions are inches (centimeters) unless otherwise indicated. Appropriate Ceiling Type Trim Type Exposed grid tee G Concealed grid tee G, ST 4-1/2 2-13/16 3-1/2 (11.4) (7.1) (8.9) 24 3” end blade depth (61.0) PHOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedures. Floor reflectances are 20%. Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request. TEST NO: LTL14671 CS PT3 MV LUMENS PER LAMP: 2850 LUM. EFF. - 75.1% LAMPS PER LUMINAIRE: 3 Coefficients of Utilization fp %02 pc 80% 70% 50% pw 50% 30% 10% 50% 30% 10% 50% 30% 10% 0 89 89 89 87 87 87 83 83 83 1 80 78 75 79 76 74 76 74 72 2 71 67 63 70 66 63 67 64 61 3 64 58 54 62 57 53 60 56 53 4 57 51 46 56 50 46 54 49 45 5 51 45 40 50 44 40 49 44 40 RCR 6 46 40 35 45 39 35 44 39 35 7 42 36 31 41 35 31 40 35 31 8 38 32 28 38 32 28 37 31 28 9 35 29 25 34 29 25 34 28 25 10 32 26 23 32 26 23 31 26 22 Zonal Lumen Summary Zone Lumens % Lamp% Fixture 0° - 30° 1982.1 23.2 30.9 0° - 40° 3413.2 39.9 53.1 0° - 60° 5866.8 68.6 91.4 0° - 90° 6422.1 75.1 100.0 90° - 180° 0.0 0.0 0.0 0° - 180° 6422.1 75.1 100.0 PARABOLICS.