PTM-305 Portable, Battery Provided Stylus to Control and Configure Powered, Personal Test Monitor Provides Each Operation

Total Page:16

File Type:pdf, Size:1020Kb

PTM-305 Portable, Battery Provided Stylus to Control and Configure Powered, Personal Test Monitor Provides Each Operation MODEL PTMPTM--305305 TEST & MEASUREMENT TEST AND MEASUREMENT PERSONAL TEST MONITOR Unparalleled flexibility in a palm-sized package. Videotek’s PTM-305 portable, battery provided stylus to control and configure powered, personal test monitor provides each operation. And maintaining power PTM-305 Specifications multi-format functionality and versatility in the field won’t be a problem • Multiple functionality that set it apart from other handheld the PTM-305 runs on standard - Color Monitor products on the market. re-chargeable “AA” NiMH batteries. No - Vectorscope special battery packs are required. With a powerful array of features and - Waveform Monitor functions that include Analog and The PTM-305 includes two video inputs, - Test Signal Generator Digital Video Test Signal Generators, one for monitoring composite analog - Embedded Audio Monitor Color Monitor, Waveform, Vectorscope NTSC and PAL video signals and the and an Audio Analyzer/Monitor, the second for monitoring SD-SDI signals - Serial Data Analyzer lightweight PTM-305 is ideal for moni- formatted in SMPTE 259M-C with • Multi-formats toring field production camera setup, embedded audio. The test signal - SD-SDI equipment installation, or troubleshoot- generator has individual outputs of - Composite Analog (PAL/NTSC) ing signal path issues related to analog composite analog video and SD-SDI. • Portable, handheld - PDA-sized and standard definition digital formats. The stereo headphone output - Weighs under one pound may be configured to monitor This PDA-sized test and measurement • Integrated 320 x 240 color embedded audio from the SDI source or instrument was designed to offer the LCD Display double as a monaural analog tone convenience of portability without generator output. • Touch Screen Operation sacrificing function and performance. To enhance the user’s experience, the Standard accessories include a PTM-305 features an integrated 320 x sunshield, stylus, batteries, battery 240 color LCD display, utilizing charger, power adapter, and a belt-style touch-screen technology and the pouch. www.amt.com • Color Picture Monitor • Audio Tone Generator - Zoom and Pulse Cross Mode - Audio frequency fixed selections - Horizontal and Vertical Offset 400 Hz, 1 kHz, 10 kHz • Waveform Monitor - Audio frequency range selections 10 Hz to 20 kHz in 10 Hz steps - Composite Video Input - Audio amplitude selections: +4, 0, -4, Composite or RGB Levels -8, -18, -20 dB, variable - Serial Digital Video Input - Audio amplitude variable range: RGB or Y, PB, PR Levels +4 dB to -59 dB in 1 dB steps - Color Display • Analog Audio monaural tone output: - Digital Line Select - THD: ≤ 1% - Persistence Adjustable - Maximum Level: +4 dBu - Zoom and Pan Mode - Connector: Miniature stereo headphone jack • Vectorscope - 16 bit DAC - 75% and 100% Display Mode • Power Management - Digital Line Select - Auto shutdown of unused functions The PTM-305’s vector display. - Persistence Adjustable - Up to 4 Hour Operation (Battery) • Serial Digital Data Analyzer (Function Dependent) - SAV Position • Serial Digital Output • Color TFT touch screen LCD - SAV XYZ Word - Return Loss > 15db at 270MHz - 320 x 240 Pixels - EAV Position - Output Data Rate 270Mb/s - 54 x 72 mm Display - EAV XYZ Word - Output Jitter ≤ 0.2 UI • Test Signal Generator - ANC Check Sum • Composite Analog Output - Test Signals - Active Field CRC - 10 bit DAC Color Bars: - Full Field CRC - Interpolation 8:8:8 Split Field 75% & 100% - EDH Flags - S/N ratio (Ramp) > 60db rms Full Field 75% & 100% - Active Picture EDH • Serial Digital Input (SMPTE - 259 M-C) Multi Burst, Multi Pulse - Full Field EDH • Composite Analog Input (NTSC - PAL) Sweep • Embedded Serial Audio Monitor • Physical Specifications Sin X - AES/EBU 48kHz Audio Data Supported - 136mm High x 80mm Wide x 35mm Deep Window test signal - Analyze any one pair from 4 groups - 411 grams (14.5 oz) - Freq. Stab. 50ppm - Stereo Bar Graph Peak Hold - Operating Temperature 0 to 40º C - EDH insertion Audio Meters - Non Operating Temperature -30 to +85º C - Embed Tone in any Single Audio Group - Stereo Bar Graph Average Audio - Power: 6 “AA” NiMH batteries with Meters - Audio Frequency and Amplitude battery charger and AC power adapters Adjustable - 16 Bit Stereo DAC included. - Serial Digital Video Output - Variable Stereo Headphone output 525/59.94, 625/50 (from embedded audio sources) - Composite Video Output NTSC-(M/J) or PAL or PAL-M Toll Free +1 800 800 5719 Main +1 610 327 2292 For more information please visit www.broadcast.harris.com/videotek Harris is a registered trademark of Harris Corporation. Trademarks and tradenames are the property of their respective companies. Broadcast Communications Division | 4393 Digital Way | Mason, OH USA 45040 www.broadcast.harris.com | Tel: 1-513-459-3400 ©2006 Harris Corporation DS_PTM_0706 .
Recommended publications
  • Modern Architecture Advances Vector Network Analyzer Performance Vector Network Analyzers (Vnas) Are Based on the Use of Either Mixers Or Samplers
    White Paper Modern Architecture Advances Vector Network Analyzer Performance Vector Network Analyzers (VNAs) are based on the use of either mixers or samplers. In traditional sampling VNAs, samplers are gated by pulses generated with a Step-Recovery Diode (SRD) circuit, with the Local Oscillator (LO) and RF source phase locked to a common frequency reference. An alternative architecture is a VNA based on Nonlinear Transmission Line (NLTL) samplers and distributed harmonic generators. NLTL-based samplers configured to provide scalable operation characteristics now offer a more beneficial alternative. Not only do they allow for a simplified VNA architecture, but they also enable VNAs that are much more cost effective than those employing fundamental mixing. This paper provides an overview of the high-frequency technology deployed in Anritsu’s VNA families. It is shown that NLTL technology results in miniature VNA reflectometers that provide enhanced performance over broad frequency ranges, and reduced measurement complexity when compared with existing solutions. These capabilities, combined with the frequency-scalable nature of the reflectometers provide VNA users with a unique and compelling solution for their current and future high-frequency measurement needs. Limitations of Prior VNA Architectures VNAs make use of samplers, harmonic mixers, or combinations thereof to down-convert measurement signals to intermediate frequencies (IF) before digitizing them. Such down-conversion components play a critical role in VNAs because they set bounds on important parameters like conversion efficiency, receiver compression, isolation between measurement channels, and spurious generation at the ports of a device under test (DUT). Mixers tend to be the down converters of choice at RF frequencies, due mainly to their simpler local oscillator (LO) drive system and enhanced spur-management advantages.
    [Show full text]
  • Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science
    Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science 6.002 - Circuits and Electronics Fall 2004 Lab Equipment Handout (Handout F04-009) Prepared by Iahn Cajigas González (EECS '02) Updated by Ben Walker (EECS ’03) in September, 2003 This handout is intended to provide a brief technical overview of the lab instruments which we will be using in 6.002: the oscilloscope, multimeter, function generator, and the protoboard. It incorporates much of the material found in the individual instrument manuals, while including some background information as to how each of the instruments work. The goal of this handout is to serve as a reference of common lab procedures and terminology, while trying to build technical intuition about each instrument's functionality and familiarizing students with their use. Students with previous lab experience might find it helpful to simply skim over the handout and focus only on unfamiliar sections and terminology. THE OSCILLOSCOPE The oscilloscope is an electronic instrument based on the cathode ray tube (CRT) – not unlike the picture tube of a television set – which is capable of generating a graph of an input signal versus a second variable. In most applications the vertical (Y) axis represents voltage and the horizontal (X) axis represents time (although other configurations are possible). Essentially, the oscilloscope consists of four main parts: an electron gun, a time-base generator (that serves as a clock), two sets of deflection plates used to steer the electron beam, and a phosphorescent screen which lights up when struck by electrons. The electron gun, deflection plates, and the phosphorescent screen are all enclosed by a glass envelope which has been sealed and evacuated.
    [Show full text]
  • Tektronix Signal Generator
    Signal Generator Fundamentals Signal Generator Fundamentals Table of Contents The Complete Measurement System · · · · · · · · · · · · · · · 5 Complex Waves · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 15 The Signal Generator · · · · · · · · · · · · · · · · · · · · · · · · · · · · 6 Signal Modulation · · · · · · · · · · · · · · · · · · · · · · · · · · · 15 Analog or Digital? · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 7 Analog Modulation · · · · · · · · · · · · · · · · · · · · · · · · · 15 Basic Signal Generator Applications· · · · · · · · · · · · · · · · 8 Digital Modulation · · · · · · · · · · · · · · · · · · · · · · · · · · 15 Verification · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 8 Frequency Sweep · · · · · · · · · · · · · · · · · · · · · · · · · · · 16 Testing Digital Modulator Transmitters and Receivers · · 8 Quadrature Modulation · · · · · · · · · · · · · · · · · · · · · 16 Characterization · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 8 Digital Patterns and Formats · · · · · · · · · · · · · · · · · · · 16 Testing D/A and A/D Converters · · · · · · · · · · · · · · · · · 8 Bit Streams · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 17 Stress/Margin Testing · · · · · · · · · · · · · · · · · · · · · · · · · · · 9 Types of Signal Generators · · · · · · · · · · · · · · · · · · · · · · 17 Stressing Communication Receivers · · · · · · · · · · · · · · 9 Analog and Mixed Signal Generators · · · · · · · · · · · · · · 18 Signal Generation Techniques
    [Show full text]
  • How to Measure the Loop Transfer Function of Power Supplies (Rev. A)
    Application Report SNVA364A–October 2008–Revised April 2013 AN-1889 How to Measure the Loop Transfer Function of Power Supplies ..................................................................................................................................................... ABSTRACT This application report shows how to measure the critical points of a bode plot with only an audio generator (or simple signal generator) and an oscilloscope. The method is explained in an easy to follow step-by-step manner so that a power supply designer can start performing these measurements in a short amount of time. Contents 1 Introduction .................................................................................................................. 2 2 Step 1: Setting up the Circuit .............................................................................................. 2 3 Step 2: The Injection Transformer ........................................................................................ 4 4 Step 3: Preparing the Signal Generator .................................................................................. 4 5 Step 4: Hooking up the Oscilloscope ..................................................................................... 4 6 Step 5: Preparing the Power Supply ..................................................................................... 4 7 Step 6: Taking the Measurement ......................................................................................... 5 8 Step 7: Analyzing a Bode Plot ...........................................................................................
    [Show full text]
  • Simple RF-Power Measurement
    By Wes Hayward, W7ZOI, and Bob Larkin, W7PUA Simple RF-Power Measurement Making power PHOTO S BY JOE BO TTIGLIERI, AA1G measurements from W nanowatts to 100 watts is easy with these simple homebrewed instruments! easuring RF power is central to power indicators. power meter, extending the upper limit by almost everything that we do as The power-measuring system de- 40 dB, allowing measurement of up to Mradio amateurs and experiment- scribed here is based on a recently intro- 100 W (+50 dBm). ers. Those applications range from sim- duced IC from Analog Devices: the ply measuring the power output of our AD8307. The core of this system is a The Power Meter transmitters to our workbench experi- battery operated instrument that allows The cornerstone of the power-meter mentations that call for measuring the LO us to directly measure signals of over circuit shown in Figure 1 is an Analog power applied to the mixers within our 20 mW (+13 dBm) to less than 0.1 nW Devices AD8307AN logarithmic amplifier receivers. Even our receiver S meters are (−70 dBm). A tap circuit supplements the IC, U1. Although you might consider the 1 Figure 1—Schematic of the 1- to 500-MHz wattmeter. Unless otherwise specified, resistors are /4-W 5%-tolerance carbon- composition or metal-film units. Equivalent parts can be substituted; n.c. indicates no connection. Most parts are available from Kanga US; see Note 2. J1—N or BNC connector S1—SPST toggle Misc: See Note 2; copper-clad board, 3 L1—1 turn of a C1 lead, /16-inch ID; see U1—AD8307; see Note 1.
    [Show full text]
  • The Essential Signal Generator Guide Building a Solid Foundation in RF – Part 2
    The Essential Signal Generator Guide Building a Solid Foundation in RF – Part 2 Introduction Having a robust and reliable high-speed wireless connection helps win and retain customers. It has quickly become a requirement for doing business. In order to meet this requirement, you need the right signal generator. As frequency spectrum is a finite resource, complex modulation schemes are needed to increase spectral efficiency, which allows for far higher data rates. Unfortunately, complex modulation schemes depend on accurate and stable signal generators to work effectively. With all the specifications and features available out there, getting the right signal generator for the job can be a daunting task. In this second part of our two-part white paper, we help you gain a sound understanding of various modulation schemes, the importance of spectral purity, and how distortion can help you. We will also explore how you can use smart software to significantly improve your productivity. Find us at www.keysight.com Page 1 Contents In Part 2 of our two-part eBook, we will highlight more advanced features such as modulation, spectral purity, and distortion. We introduced the signal generator and looked at basic specifications such as power, accuracy, and speed in Part 1. Section 5. IQ Modulation Learn about basic I/Q modulation and its key characteristics, and stress-test your designs with I/Q impairments. Section 6. Spectral Purity Spectral purity performance is a key factor in obtaining accurate measurements. Understand phase noise requirements in signal generation. Section 7. Distortion Performance Get to know the different types of distortions and why they matter to your measurements.
    [Show full text]
  • A Guide to Calibrating Your Spectrum Analyzer
    A Guide to Calibrating Your Spectrum Analyzer Application Note Introduction As a technician or engineer who works with example, the test for noise sidebands that deter- electronics, you rely on your spectrum analyzer to mines whether the spectrum analyzer meets its verify that the devices you design, manufacture, phase noise specification often expresses the results and test—devices such as cell phones, TV broadcast in dBc, while analyzer specifications are typically systems, and test equipment—are generating the quoted in dBc/Hz. Consequently, the test engineer proper signals at the intended frequencies and must convert dBc to dBc/Hz as well as applying levels. For example, if you work with cellular radio several correction factors to determine whether the systems, you need to ensure that carrier signal spectrum analyzer is in compliance with specifications. harmonics won’t interfere with other systems For these reasons, spectrum analyzer calibra- operating at the same frequencies as the harmon- tion is a task best handled by skilled metrolo- ics; that intermodulation will not distort the infor- gists, who have both the necessary equipment mation modulated onto the carrier; that the device and an in-depth understanding of the procedures complies with regulatory requirements by operating involved. Still, it’s helpful for everyone who works at the assigned frequency and staying within the with spectrum analyzers to understand the value allocated channel bandwidth; and that unwanted of calibrating these instruments. This application emissions, whether radiated or conducted through note is intended both to help application engineers power lines or other wires, do not impair the opera- who work with spectrum analyzers understand the tion of other systems.
    [Show full text]
  • HD-STAR® Handheld HD-SDI and SD-SDI Generator and Monitor
    HD-STAR® Handheld HD-SDI and SD-SDI Generator and Monitor FEATURES • Multiple functionality – Color monitor – Vectorscope – Waveform monitor VIDEO TEST – Test signal generator – Embedded audio monitor // – Serial data analyzer T N • Multiformats – HD-SDI – SD-SDI EME • Portable, handheld – PDA-sized SUR – Weighs under one pound with battery • Integrated 320x240 color LCD display EA • Touchscreen operation ND M A PRODUCT DETAILS T With a powerful array of features and functions that include a video test signal gen- S erator, color monitor, waveform monitor, vectorscope, serial data analyzer and an au- E T dio analyzer/monitor, the lightweight HD-STAR is ideal for monitoring field production camera setup, equipment installation, or troubleshooting signal path issues related to high-definition and standard-definition digital formats. The Videotek® HD-STAR® is a portable, battery-powered HD-SDI and SD-SDI This PDA-sized test monitor was designed to offer the convenience of portability without video generator and monitor. Also possessing embedded audio generator and sacrificing function and performance. To enhance the user’s experience, the HD-STAR monitor capabilities, the HD-STAR provides a level of multiformat functionality and features an integrated 320x240 color LCD display, utilizing touchscreen technology to control and configure each operation. Maintaining power in versatility that sets it apart from other handheld test and measurement products the field won’t be a problem — the HD-STAR runs on a Li-Ion battery pack. on the market. The HD-STAR includes one looping video input for monitoring HD-SDI and SD-SDI sig- nals formatted in SMPTE 292 M or SMPTE 259 M-C with embedded audio.
    [Show full text]
  • The 802R-PCI Is a Programmable Video Signal Generator for Testing Analog Hundreds of Formats and Patterns Included
    KEY FEATURES + BENEFITS 24 bits per pixel up to 100 MHz. 8-bits up to 300 MHz. Analog-VGA and Digital-EGA outputs. Compact 1/2-slot PCI card size Self-calibrating analog video outputs are electronically adjusted against an internal precision reference. Video Generator Manager provides VIDEO TEST GENERATOR a Microsoft Windows-based user interface to the generator. The 802R-PCI is a programmable video signal generator for testing analog Hundreds of formats and patterns included. and digital devices. The compact 1/2-slot PCI-based design saves space in HDTV/SDTV Signal Support. production environments. Control the generator with our Video Generator Generates bi-polar sync and YPrPb color difference video. Manager software, or use our Software Development Kit to create with your Software Development Kit for writing own application. Or use the extensive command interface to programatically your own Windows® or DOS control every aspect of the generator, from loading video formats and images, applications to control generator. to creating custom video formats and images. Create test sequences to auto- Display bitmap images stored on PC. mate repetitive testing procedures. PC memory mapped for drawing directly into the generators video memory from your application using your PC's processor. DMA. High speed 32-bit PCI data bus at 33 MHz. 5 volt or 3.3 volt PCI slot. User-installable firmware and gate- ware. 802R-PCI APPLICATION TESTS SPECIFICATIONS 802R-PCI HDCP Pixel Clock Device Communication HDMI and DVI Authentication and encryption of Range:
    [Show full text]
  • Design of Multiple Waveform Generator & Frequency Counter
    International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395 -0056 Volume: 03 Issue: 07 | July-2016 www.irjet.net p-ISSN: 2395-0072 Design of Multiple Waveform Generator & Frequency Counter Based On DDS Mr. Pranjal A. Charde1, Prof. P.R. Lakhe2, Mr. Akshay P. Nanote3 1 M. Tech. Research Scholar, Electronics (Communication Engg.)S.D.C.E. Selukate, Wardha, Maharashtra, India 2Assistant Professor Department of Electronics and Communication Engineering S.D.C.E. Selukate. Wardha, Maharashtra, India 3Assistant Manager Gupta Energy Pvt. Ltd., Deoli, Wardha, Maharashtra, India ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - Direct Digital Synthesizer (DDS) is important role in modern digital communication. DDS is new frequency synthesis technique which starts from the concept of phase and directly synthesis waveform required. It has beneficial for fast frequency switching, fine frequency resolution, large bandwidth, and good spectral purity. DDS consists of a phase accumulator, a phase to sine amplitude converter, digital to analog converter. The DDS consisting multiple waveform Fig. DDS Architecture generators. DDS producing sine and cosine output Phase Accumulator: - It consists of Phase register and simultaneously by using only one lookup table. It has adder. Input 32 bit is provided to phase accumulator able to work in high speed frequencies and it is a method for each clock cycle, the content of phase register for digitally creating arbitrary waveforms from a single, increases by adding previous count and current count fixed frequency reference clock. It also consumes very then corresponding voltage level value is provided to less power than the conventional signal generator. DDS LUTs. circuit occupies less area and power dissipation.
    [Show full text]
  • Better Measurements Using RF Signal Generators Application Note 1390 Signal Sources Provide Precise, HINT 1
    9 Hints for Making Better Measurements Using RF Signal Generators Application Note 1390 Signal sources provide precise, HINT 1. HINT 6. highly stable test signals for a Improve Source’s Effective Improve FM Deviation Accuracy variety of component and system Harmonic Distortion test applications. Signal generators Use the Bessel Null method to set add precision modulation capabili- Use a low pass filter at the output of your signal generator’s frequency ties, and are used to simulate system your source to decrease its harmonic deviation. signals for receiver performance distortion. testing. HINT 7. HINT 2. Extend the Amplitude Range This guide helps you improve the Increase Power Level Accuracy accuracy of your measurements that Use an amplifier or an attenuator to involve using RF signal sources. You Use a power meter to increase the increase or decrease respectively, may increase the accuracy of your accuracy of the signal level at your the amplitude range of your signal data by using more than one of the device under test (DUT). source. hints in your test setup. HINT 3. HINT 8. Improve Frequency Accuracy Optimizing ACLR for CDMA Receiver Testing Select the appropriate frequency reference to improve absolute or Use the attenuator hold function to relative frequency accuracy. optimize for ACLR. HINT 4. HINT 9. Improve Source Match Select the Optimum Phase Noise Profile Use a fixed attenuator to reduce the mismatch error. Choose the appropriate phase noise profile to optimize in-channel or HINT 5. out-of-channel measurements. Combine Source Outputs for TOI Measurements Use a proper setup to isolate sources,improve match.
    [Show full text]
  • Course 1 RF Measurements Techniques Instructions
    CERN Accelerator School Course 1 RF Measurements Techniques Instructions Fritz Caspers Piotr Kowina Intermediate Level Accelerator Physics, CAS 2011, Chios, Greece Suggested measurements – overview Spectrum Analyzer test stand 1 Measurements of several types of modulation (AM FM PM) in the time and frequency domain. Superposition of AM and FM spectrum (unequal carrier side bands). Concept of a spectrum analyzer: the superheterodyne method. Practice all the different settings (video bandwidth, resolution bandwidth etc.). Advantage of FFT spectrum analyzers. Spectrum Analyzer test stand 2 Measurement of the TOI point of some amplifier (intermodulation tests). Concept of noise figure and noise temperature measurements, testing a noise diode, the basics of thermal noise. EMC measurements (e.g.: analyze your cell phone spectrum). Nonlinear distortion in general concept and application of vector spectrum analyzers, spectrogram mode. Measurement of the RF characteristic of a microwave detector diode (output voltage versus input power... transition between regime output voltage proportional input power and output voltage proportional input voltage). Spectrum Analyzer test stand 3 Concept of noise figure and noise temperature measurements, testing a noise diode, the basics of thermal noise. Noise figure measurements on amplifiers and also attenuators. The concept and meaning of ENR numbers. Noise temperature of the fluorescent tubes in the room using a satellite receiver Network Analyzer test stand 1 Calibration of the Vector Network Analyzer. Navigation in the Smith Chart. Application of the triple stub tuner for matching. Measurements of the light velocity using a trombone (constant impedance adjustable coax line) in the frequency domain. N-port (N=1…4) S-parameter measurements for different reciprocal and non- reciprocal RF-components.
    [Show full text]