Certific at E of Insy Ection
Total Page:16
File Type:pdf, Size:1020Kb
United States of America Department of Homeland Security United States Coast Guard Certific at e of Insy ection For ships on international voyages this certificate fulfills the requirements of SOLAS 74 as amended, regulation V/1 4, for a SAFE MANNING DOCUI\,4ENT Vessel Name Official Number IMO Number Call Sign Service FMT 3298 1294599 Tank Barge Hailing Port Hull l,4aterial Horsepower Propulsion NEW ORLEANS, LA Steel UNITED STATES Place Built Deliwry Date Keel Laid Date Gross Tons Net Tons DWT Length ASHLAND CITY, TN R-1619 R-1 6 13 R-297.5 29Ju12019 14Jun2019 894 t- t- t-0 Owner Operator AMERICAN INLAND MARINE LLC FMT INDUSTRIES LLC 3838 NORTH CAUSEWAY BLVD STE 3335 2360 FIFTH STREET METAIRIE, LA 7OOO2 MANDEVILLE, LA70471 UNITED STATES UNITED STATES This vessel must be manned with the following licensed and unlicensed Personnel. lncluded in which there must be 0 Certified Lifeboatmen, 0 Certified Tankermen, 0 HSC Type Rating, and 0 GMDSS Operators. 0 Masters 0 Licensed Mates 0 Chief Engineers 0 Oilers 0 Chief Mates 0 First Class Pilots 0 First Assistant Engineers 0 Second Mates 0 Radio Officers 0 Second Assistant Engineers 0 Third Mates 0 Able Seamen 0 Third Assistant Engineers 0 Master First Class Pilot 0 Ordinary Seamen 0 Licensed Engineers 0 Mate First Class Pilots 0 Deckhands 0 Qualified Member Engineer ln addition, this vessel may carry 0 Passengers, 0 Other Persons in crew, 0 Persons in addition to crew, and no Others. Total Persons allowed:0 Route Permitted And Conditions Of Operation: ---Lakes, Bays, and Sounds plus Limited Coastwise-- Also, in fair weather only, linited coastwise, not more than twelve (12) mifes from shore between St. Marks and Carrabelle, Florida. (does not require a loadline certificate.) This vessel has been granted a fresh water service examination interval in accordance with 46 CFR 31.10-21(a) (2\ . Tt this vessef is operated in salt water more than slx months in any twelve month period, the vessel must be inspected using salt water intervals per 46 cFR 31.10-21(a) (1)and the cognizant ocMI notified in writing as soon as this change in status occurs. ***SEE NEXT PAGE FOR ADDITIONAL CERTIFICATE INFORMATION*** With this lnspection for Certification having been completed at Ashland City, TN, UNITED STATES, the Officer in Charge, Marine lnspection, Sector Ohio Valley certified the vessel, in all respects, is in conformity with the laws and the rules and reoulations prescribed thereunder. |1f,ff&q;,elinsPection Annual/Period iclRe-lnspection This certificate Date Zone A/P/R Signature R.S. WAD USCG, By Direction Officer in Charge Sector Ohio Valley lnspection Zone Dcpt. Sec., USCG, CG-841 (Rev 4-2000)(v2) OMB No. 2l l5-0517 United States of America Certification Date: 29 Jul2O19 Department of Homeland Security iration Date: 29 Jul2024 United States Coast Guard Certfficat e of Insy ection Vessel Name: FMT 3298 ---Hull Exams--- Exam Type Next Exam Last Exam Prior Exam DryDock 31Ju12029 29Jut2019 lnternalStructure 31Ju12024 29Ju12019 --- Liquid/Gas/Solid Gargo Authority/Conditions --- AuthoTization: FLAMMABLE/COMBUSTIBLE LIQUIDS IN 46 CFR TABLE 30,25-1AND SPECIFIED HAZARDOUS CARGOES TotalCapacity Units Highest Grade Type Part151 Regulated Par1153 Regulated Part154 Regulated 28966 Barrels A Yes No No *Hazardous Bulk Solids Authority* Not Authorized *Loading Gonstraints - Structural* Tank Number Max Cargo Weight per Tank (short tons) Maximum Density (lbs/gal) 1PlS 861 13.58 2 PtS 874 13.58 3 PiS 754 13.58 SLOP P/S *Loading Constraints - Stability. Hull Type Maximum Load Maximum Draft Max Density Route Description (short tons) (fVin) (lbs/gal) ll 3910 10ft 3in 13.58 R, LBS lll 4740 11ft 11in 13.58 R, LBS *Gonditions Of Carriage* Only those cargoes named in the vessel's Cargo Authority Attachment, Serial No. C1-1902062, dated 26-Jun-2019 may be carried, and then only in the tanks indicated. When the vessel is carrying cargoes containing greater than 0.5% benzene, the person in charge is responsible for ensuring the provisions of 46 US Code of Federal Regulations Part 197, Subpart C are Applied. Per 46 CFR 1 50.1 30, the person in charge of the vessel is responsible for ensuring the compatibility requirements of 46 CFR 150 are met. Cargoes must be checked for compatibility using the figures, tables, and appendices of 46 CFR 150 in conjunction with the reactive group numbers from the "Compat Group No" column listed in the vessel's Cargo Authority Attachment. The maximum design density of cargo which may be filled to the tank top is 8.74 lbs/gal. Cargoes with higher densities, up to 13.5B lbs/gal, may be carried as slack loads, but shall not exceed the tank weight limits as listed below. Note: per46 CFR 151.10-15(cX2) the maximum tank weights listed above reflect uniform (within 5%) loading at the deepest draft allowed. When carrying Subchapter "O" cargoes at shallower drafts, the barge should always be loaded uniformly. **"VAPOR CONTROL SYSTEM*** ln accordance with 46 CFR 39, excluding part 39.4000, this vessel's vapor colleclion system has been inspected to the plans approved by MSC Letter C1-1902062 dated June 26, 2019 and has been found acceptable for the collection of bulk liquid cargo vapors annotated with "Yes" in the CAA's VCS column of the vessels's Cargo Authority Attachment. Dept. olHome Sec., USCG, CG-841 (Rev Page 2 of 3 OMB l7 United States of America Department of Homeland Security United States Goast Guard Certific at e of Insy ection Vessel Name: FMT 3298 The VCS system has been approved with a pressure side 1.5 psig Ptu valve with Coast Guard Approval162.017116714. The cargo tank top is suitable for a maximum allowable working pressure (MAWP) of 3 psi When the vessel is carrying cargoes containing greater than 0.5% benzene, the person in charge is responsible for ensuring the provisions of 46 US Code of Federal Regulations Part 197, Subpart C are applied. ln accordance with 46 CFR Part 39.1017 and 39.5000(e) this vessel's VCS has been evaluated and approved for multi- breasted tandem loading with other vessels specifically approved to tandem load with this vessel. -- lnspection Status -- *Fuel Tanks* lnternal Examinations Tank lD Previous Last Next AFT - 29Ju12019 *Cargo Tanks* lnternal Exam External Exam Tank ld Previous Last Next Previous Last Next 1 P/S 29Ju12019 31Ju12029 2 P/S 29Ju12019 31Ju12029 3 P/S 29Ju12019 31Ju12029 SLOP P/S 29Ju12019 31Ju12029 Hydro Test Tank ld Safety Valves Previous Last Next 1 P/S 29Ju12019 2PtS 29Ju12019 3 P/S 29Ju12019 SLOP P/S 29Ju12019 ---Gonditional Portable Fire Extinguisher Requirements--- Required Only During Transfer of Cargo or Operation of Barge Machinery --- Fire Fighting Equipment -- *Fire Extinguishers - Hand portable and semi-portable* Quantity Class Type 2 40-B ***END*** Dept. ofHorne Sec., USCG, CG-84t (Rev 4-2000)(v2) Page 3 of 3 No.2l l5-0517 [)cpartmcnt ol' Ilonieland Security Serial #: c1 - 1 902062 United States Coast Guard Dated: 26-Jun-19 Certfficute of Inspection C urgo A uthority Attachment Vessel Name: FMT 3298 Shipyard: Arcosa Ashland City officiar #: -1294599 Hull #: 5411 46 CFR 151 Tank Group Characteristics Tank Group Cargo ldentitl€lion Ca.go Enviaonmenlal lnfomation Tanks Special R€quirenrents Transfer Control Tnk Hull I'landling Temp Grp Taiks in Group Densily Press. , Temp. Tvp TYPe lG"uge Tanks Provided Space General Cont 13.6 A{mos. Amb ll 1ii lntegral PV Closed lt G i NR NA Ponabie .50,60..50,7qa). 55'1{b). {c), (e). (t). l.lR No 2ii Gravity .50 70{b), so,73, 0), 56,1 (a), (b). (c), .50'81(a).50- (d), (e). (r). (s). B1(b), Notes l under Environmenlal con{rol. Tanks, NR reans lhat the tank group is suitable only for those €rgoes whlch requre no environmen{al @ntrol in the €rgo lanks. that the vessel does rDl ha'/e a cargo controt space, and lhis requiremeol i;not applied. equipmenl located in a hazardous l@lion List of Authorized Ca Cargo ldentification Conditions of C arriage i i Vapor Re@very Compat I Chem Gro!p Sub Hull Tank I Appd VCS Special Requirements in 46 CFR lnsp. Name Code Grade No Chapler Type Group r{Yo.N) Category 1 51 General and Mal'ls of Period Authorized Subchapter O Carqoes Sodium acetate solution sAN 34 0/O 3 # A No N/A Acetonitrile ATN 37 o c lil A Yes 3 G Acrylonjtrile ACN 1s2 o c lt A Yes 4 s0.70{a)..55-1(e) Adiponitrile ADN o-' E ilA Yes 1 Alkyi (C7-C9) nilrates AKN 342 o NA III A No NiA 50.81..50.86 G Aminoelhvl ethanolamine AEE B OElllAYes1.55-1(b) G Ammonium bisullite solution (70% or less) ABX 43 o NA ill No N/A .50 73. 56-t(a), (bl. (c) G Ammonium hydroxide (28% or less NH3) AMH 6 o NA ilt No N/A .5Gr(a), tbt. {c). (0, (s) G Anlhracene oil (Coal lar fraclion) AHO o NA il No No Benzene BNZ oc llt Yes .5G60 G Benzene or hydrocarbon mixtures (having 10% Benzene or more) BHB 322 oc ilt Yes .50-60 Benzene or hydrocarbon (containing 1t2 mixtures Acelylene and 10% BHA oc lrl Yes .50.60, .s6 1(b). (d). (f). (s) c Benzene or Benzene. Toluene, Xylene mixtures (10% Benzene or more) BTX 32 O B/C ilt A yes 1 5$60 G Butyl acrylate (all isomers) BAR 14 o D ilt Yes 2 .5G70(a),.50€l(a), (b) G Butyl methacrylate BMH 14 o D ilt Yes 2 .s0 70(a).