Arc Fault Circuit Interrupters the Next Generation of Fire Prevention - the Next Generation of Recovery Opportunities
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Xpole Pfim-X
Eaton.com Protective Devices Residual Current Devices PFIM-X Catalog Protective Devices General 1.1 Residual Current Devices - General Data Short description of the most important RCD types Symbol Description Eaton standard. Suitable for outdoor installation (distribution boxes for outdoor installation and building sites) up to -25° C. Conditionally surge-current proof (>250 A, 8/20 µs) for general application. Type AC: AC current sensitive RCCB Type A: AC and pulsating DC current sensitive RCCB, not affected by smooth DC fault currents up to 6 mA Type F: AC and pulsating DC current sensitive RCCB, trips also at frequency mixtures (10 Hz, 50 Hz, 1000 Hz), min. 10 ms time-delayed, min. 3 kA surge current proof, higher load capacity with smooth DC fault currents up to 10 mA Frequency range up to 20 kHz Trips also at frequency mixtures (10 Hz, 50 Hz, 1000 Hz) Type B: All-current sensitive RCD switchgear for applications where DC fault currents may occur. Non-selective, non- delayed. Protection against all kinds of fault currents. Type B+: All-current sensitive RCD switchgear for applications where DC fault currents may occur. Non-selective, non-delayed. Protection against all kinds of fault currents. Provides enhanced fire safety. RCD of type G (min 10 ms time delay) surge current-proof up to 3 kA. For system components where protection G against unwanted tripping is needed to avoid personal injury and damage to property. Also for systems involving ÖVE E 8601 long lines with high capacitive reactance. Some versions are sensitive to pulsating DC. Some versions are available in all-current sensitive design. -
The IT Earthing System (Unearthed Neutral) in LV
Collection Technique .......................................................................... Cahier technique no. 178 The IT earthing system (unearthed neutral) in LV F. Jullien I. Héritier “Cahiers Techniques” is a collection of documents intended for engineers and technicians, people in the industry who are looking for more in-depth information in order to complement that given in product catalogues. Furthermore, these “Cahiers Techniques” are often considered as helpful “tools” for training courses. They provide knowledge on new technical and technological developments in the electrotechnical field and electronics. They also provide better understanding of various phenomena observed in electrical installations, systems and equipments. Each “Cahier Technique” provides an in-depth study of a precise subject in the fields of electrical networks, protection devices, monitoring and control and industrial automation systems. The latest publications can be downloaded from the Schneider Electric internet web site. Code: http://www.schneider-electric.com Section: Experts’ place Please contact your Schneider Electric representative if you want either a “Cahier Technique” or the list of available titles. The “Cahiers Techniques” collection is part of the Schneider Electric’s “Collection technique”. Foreword The author disclaims all responsibility subsequent to incorrect use of information or diagrams reproduced in this document, and cannot be held responsible for any errors or oversights, or for the consequences of using information and diagrams contained in this document. Reproduction of all or part of a “Cahier Technique” is authorised with the prior consent of the Scientific and Technical Division. The statement “Extracted from Schneider Electric “Cahier Technique” no. .....” (please specify) is compulsory. no. 178 The IT earthing system (unearthed neutral) in LV François JULLIEN Joined Schneider Electric’s Low Voltage activity in 1987. -
Technical Application Papers No.3 Distribution Systems and Protection Against Indirect Contact and Earth Fault
Technical Application Papers No.3 Distribution systems and protection against indirect contact and earth fault Technical Application Papers Distribution systems and protection against indirect contact and earth fault Index 6.2.1 Miniature circuit-breakers System pro M and System pro M compact with 1 Introduction ........................................2 residual current protection ....................23 6.2.2 Residual current releases for Tmax 2 Main definitions ..............................3 moulded-case circuit-breakers ..............28 6.2.3 Electronic releases PR… ranges for 3 Protection against earth moulded-case and air circuit-breakers with integrated residual current protection ....29 fault 6.2.4 Residual current relay with external transformer ...........................................30 3.1 General aspects ......................................5 6.3 The solution with function G ..................31 4 Classification of electrical 6.4 Protection function G or residual current distribution systems protection? ...........................................33 6.4.1 Typical applications of residual current ........................................... circuit-breakers 4.1 TT system ...............................................6 33 4.2 TN system ...............................................6 6.4.2 Typical applications of moulded-case 4.3 IT system ................................................7 and air circuit-breakers equipped with function G against earth fault .................34 4.4 Conclusions ............................................7 -
Circuit Breaker Control Guidelines for Vacclad-W Metal-Clad Switchgear
Application Paper AP083012EN Circuit breaker control guidelines for VacClad-W metal-clad switchgear Circuit breaker control Control breaker control equipment Relays Eaton’s VCP-W circuit breaker has a motor charged Microprocessor-based or solid-state relays spring type stored energy closing mechanism. would generally require dc power or reliable Closing the breaker charges accelerating springs. uninterruptible ac supply for their logic circuits. Protective relays or the control switch will energize a shunt trip coil to release the accelerating springs Auxiliary switches and open the breaker. This requires a reliable Optional circuit breaker and cell auxiliary switches source of control power for the breaker to function are available where needed for interlocking or as a protective device. Figure 2 and Figure 3 control of auxiliary devices. Typical applications and show typical ac and dc control schematics for type operation are described in Figure 1 and Table 1. VCP-W circuit breakers. Breaker auxiliary switches and MOC switches For ac control, a capacitor trip device is used are used for breaker open/close status and with each circuit breaker shunt trip to ensure that interlocking. energy will be available for tripping during fault conditions. A control power transformer is required Auxiliary contacts available for controls or external on the source side of each incoming line breaker. use from auxiliary switch located on the circuit Closing bus tie or bus sectionalizing breakers breaker are typically limited in number by the will require automatic transfer of control power. breaker control requirements as follows: This control power transformer may also supply • Breakers with ac control voltage: 1NO and 3NC other ac auxiliary power requirements for the switchgear. -
7 CONTROL and PROTECTION of HYDRO ELECTRIC STATION 7.1 Introduction 7.1.1 Control System the Main Control And
CHAPTER –7 CONTROL AND PROTECTION OF HYDRO ELECTRIC STATION 7.1 Introduction 7.1.1 Control System The main control and automation system in a hydroelectric power plant are associated with start and stop sequence for the unit and optimum running control of power (real and reactive), voltage and frequency. Data acquisition and retrieval is used to cover such operations as relaying plant operating status, instantaneous system efficiency, or monthly plant factor, to the operators and managers. Type of control equipment and levels of control to be applied to a hydro plant are affected by such factors as number, size and type of turbine and generator. The control equipment for a hydro power plant include control circuits/logic, control devices, indication, instrumentation, protection and annunciation at the main control board and at the unit control board for generation, conversion and transmission operation including grid interconnected operation of hydro stations including small hydro stations. These features are necessary to provide operators with the facilities required for the control and supervision of the station’s major and auxiliary equipment. In the design of these features consideration must be given to the size and importance of the station with respect to other stations in the power system, location of the main control room with respect to the equipments to be controlled and all other station features which influence the control system. The control system of a power station plays an important role in the station’s rendering reliable service; this function should be kept in mind in the design of all control features. -
Microgrid Design Considerations
Microgrid Design Considerations Dr. Arindam Maitra, EPRI September 8, 2016 Part 3 of 3 © 2015 Electric Power Research Institute, Inc. All rights reserved. Outline – Microgrid Design and Analysis Tutorial Part II Time Topics 14:30-15:00 Design analysis • Needs and Key Interconnection Issues (Arindam Maitra) 15:30-17:30 Design analysis (cont.) • Methods and Tools • Case Studies #1: Renewable Rich Microgrids - Protection Case Studies (Mohamed El Khatib) #2: Rural radial #3: Secondary n/w 17:00-17:30 Q&A 17:30 Adjourn 2 © 2015 Electric Power Research Institute, Inc. All rights reserved. Microgrids .Optimization of microgrid design is challenging and inherently contains many unknowns… Regulatory Issues Value of Resiliency System Design Challenges Engineering Studies Costs 3 © 2015 Electric Power Research Institute, Inc. All rights reserved. Integrating Customer DER with Utility Assets Customer Utility Assets Assets Micro Grid Controller SCADA/DMS/ / DERMS* Enterprise Integrate d Grid Energy Storage* Isolating Device* Distribution Transformer *New assets 4 © 2015 Electric Power Research Institute, Inc. All rights reserved. Microgrid Types .Commercial/Industrial Microgrids: Built with the goal of reducing demand and costs during normal operation, although the operation of critical functions during outages is also important, especially for data centers. .Community/City/Utility and Network Microgrids: Improve reliability of critical infrastructure, deferred asset investment, emission and energy policy targets and also promote community participation. .University Campus Microgrids: Meet the high reliability needs for research labs, campus housing, large heating and cooling demands at large cost reduction opportunities, and lower emission targets. Most campuses already have DG resources, with microgrid technology linking them together. -
EDTI's Technical Guideline for Interconnection of Generators to The
TECHNICAL GUIDELINE FOR THE INTERCONNECTION OF DISTRIBUTED ENERGY RESOURCES TO EPCOR DISTRIBUTION AND TRANSMISSION INC.’S DISTRIBUTION SYSTEM January 5, 2017 Francesco Mannarino SVP, Electricity Operations Mansur Bitar Director, Distribution Kirstine Hull Director, Planning & Engineering Darren McCrank Director, System Operations Rob Reimer Director, Metering & Wholesale Energy Suresh Sharma Director, Transmission EPCOR acknowledges the use of other documents developed by the utility industry and industry committees as the framework and sources in producing this technical guideline. Technical Guideline for Interconnection of Distributed Energy Resources to EDTI’s Distribution System Version 3 2 CONTENTS INTRODUCTION AND LIMITATION 6 1.0 GENERAL INTERCONNECTION AND PROTECTION REQUIREMENTS 9 1.1 EDTI’S DISTRIBUTION SYSTEM 10 1.1.1 General Characteristics 11 1.1.2 System Frequency 11 1.1.3 Voltage Regulation 11 1.1.4 Power Quality 12 1.1.5 Voltage Unbalance 12 1.1.6 Fault Levels 12 1.1.7 System Grounding 12 1.1.8 Fault and Line Clearing 12 1.1.9 Limit for DER Connection 13 1.2 DER FACILITY 13 1.2.1 Smart Inverters 1.2.2 Mitigation of Adverse Effects 13 1.2.3 Synchronism 13 1.2.4 Voltage Regulation and Power Factor 14 1.2.5 Frequency Control 15 1.2.6 Voltage Unbalance 16 1.2.7 Grounding 16 1.2.8 Resonance and Self-Excitation of Induction Generators 16 1.2.9 Single-Phase DER Facilities 16 Technical Guideline for Interconnection of Distributed Energy Resources to EDTI’s Distribution System Version 3 3 1.3 INTERCONNECTION 17 1.3.1 Safety 17 1.3.2 -
Connecting a Microgeneration System to a Domestic Or Similar Electrical Installation
Best Pracce Guide 3 (Issue 3) Connecting a microgeneration system to a domestic or similar electrical installation (in parallel with the mains supply) Page 1 Best Practice Guide Electrical Safety First is indebted to the following organisations for their contribution and/or support to the development of this Guide: BEAMA In electronic format, this Guide is intended to be made available free www.beama.org.uk of charge to all interested parties. Further copies may be downloaded from the websites of some of the contributing organisations. British Gas www.britishgas.co.uk The version of this Guide on the Electrical Safety First website (www.electricalsafetyfirst.org.uk) will always be the latest. Feedback on any of the Best Practice Guides is always welcome – email Certsure [email protected] www.certsure.com Electrical Safety First is supported by all sectors of the electrical industry, approvals and research bodies, consumer interest City & Guilds organisations, the electrical distribution industry, professional institutes www.cityandguilds.com and institutions, regulatory bodies, trade and industry associations and federations, trade unions, and local and central government. ECA *Electrical Safety First (formerly the National Inspection Council for www.eca.co.uk Electrical Installation Contracting) is a charitable non-profit making organisation set up in 1956 to protect users of electricity against the ENA hazards of unsafe and unsound electrical installations. www.energynetworks.org HSE www.hse.gov.uk Institution of Engineering -
All About Control Transformers
® All About Control Transformers Introduction Calculating the transformer VA Power Control transformers change the high Line Voltage to a lower Requirement voltage that is used to control HVAC, Refrigeration, and other Transformer power is rated by the VA (Volt-Amperes) capability. equipment. The Line Voltage is called the Primary Voltage and To determine the required transformer VA, multiply the the Control Voltage is called the Secondary Voltage. All transformer output control voltage by the required Amperes. transformers are used only with Alternating Voltage and Current, abbreviated as VAC. Transformers do not convert Alternating VA=Volts X Amperes Voltage to Direct Voltage, abbreviated as DCV or simply DC. To determine the maximum output current of a transformer, divide the transformer VA rating by the transformer output voltage. Control Voltage and Class 2 Specifications Amperes=VA/Volts The HVAC/R industry standard control voltage is 24 VAC. This voltage was chosen because it is high enough to power most motor start contactors, fan relays, and other related equipment Using a Circuit Breaker Control but not high enough to cause harm to individuals. Transformer to find Defective Components For safety, control transformers should be UL or CSA recognized If a technician finds the control transformer in defective as Class 2 transformers. This safety rating guarantees the equipment does not have a 24 VAC output, most of the time following safety specifications: something caused the transformer to fail and simply replacing the transformer will not solve the problem. A) The maximum control voltage is 30 VAC. If a voltage is 30 VAC or less it will not harm an individual. -
Hydropower Plants As Black Start Resources
Hydropower Plants as Black Start Resources May 2019 Jose R. Gracia Patrick W. O’Connor Lawrence C. Markel Rui Shan D. Thomas Rizy Alfonso Tarditi ORNL/SPR-2018/1077 Approved for public release. Distribution is unlimited. Acknowledgments This work was authored by Oak Ridge National Laboratory, managed by UT-Battelle for the US Department of Energy, under contract DE-AC05-00OR22725 and supported by the HydroWIRES Initiative of the Energy Department’s Water Power Technologies Office (WPTO), under contract number DE-AC05-00OR22725. The authors would like to thank Stephen Signore of Oak Ridge National Laboratory for his help in determining the makeup of current black start units in the United States. Additional thanks go to Alejandro Moreno, Samuel Bockenhauer, and Rebecca O’Neil for their thoughtful comments on drafts of the white paper. HydroWIRES The US electricity system is changing rapidly with the large-scale addition of variable renewables, and the flexible capabilities of hydropower (including pumped storage hydropower) make it well-positioned to aid in integrating these variable resources while supporting grid reliability and resilience. Recognizing these challenges and opportunities, WPTO has launched a new initiative known as HydroWIRES: Water Innovation for a Resilient Electricity System. HydroWIRES is principally focused on understanding and supporting the changing role of hydropower in the evolving US electricity system. Through the HydroWIRES initiative, WPTO seeks to understand and drive utilization of the full potential of hydropower resources to contribute to electricity system reliability and resilience, now and into the future. HydroWIRES is distinguished in its close engagement with the US Department of Energy (DOE) national laboratories. -
HARNESSING HYDROPOWER the Earth’S Natural Resource
HARNESSING HYDROPOWER The Earth’s Natural Resource WESTERN AREA POWER ADMINISTRATION DAM AND HYDRO POWERPLANT SWITCHYARD INDEPENDENT POWER PRODUCER ELECTRIC COOP-OWNED OR OR INVESTOR-OWNED UTILITY MUNICIPAL UTILITY-OWNED GENERATION GENERATION HIGH-VOLTAGE TRANSMISSION DISTRIBUTION UTILITY SUBSTATION FARM HOME SMALL BUSINESS HOW ELECTRICITY REACHES YOU The hydropower system begins at a dam, where the powerplant converts the force of flowing water into electricity. Transmission lines carry electricity from the dam to a switchyard, which increases voltage for transmission across the country. Electricity is delivered to local utilities at substations, which decrease voltage for safe distribution to homes and businesses in cities, towns and rural areas. It provides light, runs electric motors, computers and appliances, and operates pumps to irrigate crops, using the same water originally used to generate that power. INTRODUCTION he growth of civilization has been linked to our ability to capture and use the force of flowing water to our benefit. Power from rushing water was first harnessed to process T food and provide energy for factories and plants. Over time that water power also became useful for efficient hydroelectric generation. Because the fuel for hydropower is supplied by nature’s own self-renewing hydrologic cycle—rain and snow filling the rivers, rivers rushing to the seas and water evaporating again to form clouds—it is an environmentally clean, renewable and economical energy source. Today hydroelectric plants use water power to produce seven percent of the nation’s electrical supply. HISTORY OF HYDROPOWER The water-driven machine is an ancient invention. In fact, the water- wheel was the first application of power- driven machinery. -
Teaching Power Circuit Breaker Testing to Undergraduates
Paper ID #23949 Teaching Power Circuit Breaker Testing to Undergraduates Dr. Glenn T. Wrate P.E., Northern Michigan University Glenn T. Wrate received his B.S.E.E. and M.S.E.E. from Michigan Technological University (MTU) in 1984 and 1986, respectively. While attending MTU, he worked for Bechtel Power Corporation on the Belle River and Midland power generating stations. After graduating MTU, he worked for the Los Ange- les Department of Water and Power from 1986 to 1992, primarily in the Special Studies and High Voltage DC (HVDC) Stations Group. He returned to MTU in 1992 to pursue a Ph.D. in Electrical Engineering. While completing his research he worked in the relay testing group at Northern States Power Company in Minneapolis. After obtaining his Ph.D., Glenn accepted an appointment as an Assistant Professor in the Electrical Engineering and Computer Science department at the Milwaukee School of Engineering (MSOE). In 1999 he was promoted to Associate Professor, in 2001 he won the Falk Engineering Educator Award and was promoted to head the Master of Science in Engineering (MSE) program. He received the Karl O. Werwath Engineering Research Award in 2003. In 2004 he moved from the MSE program to take over the Electrical Engineering program. After guiding the program through accreditation, he stepped down in 2007. Dr. Wrate has now returned to his boyhood home and is teaching at Northern Michigan University. He is a member of HKN and IEEE, a Registered Professional Engineer in California, and is a past chair of the Energy Conversion and Conservation Division of ASEE.