W05 Emergency Water Supply for Firefighting
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Technical Bulletins: Drinking from a Fire Hydrant: the Fire Department's Role in Protecting the Public Water System
University of Tennessee, Knoxville TRACE: Tennessee Research and Creative Exchange MTAS Publications: Technical Bulletins Municipal Technical Advisory Service (MTAS) 3-1-2006 Technical Bulletins: Drinking from a Fire Hydrant: The Fire Department's Role in Protecting the Public Water System Gary West Municipal Technical Advisory Service Follow this and additional works at: https://trace.tennessee.edu/utk_mtastech Part of the Public Administration Commons The MTAS publications provided on this website are archival documents intended for informational purposes only and should not be considered as authoritative. The content contained in these publications may be outdated, and the laws referenced therein may have changed or may not be applicable to your city or circumstances. For current information, please visit the MTAS website at: mtas.tennessee.edu. Recommended Citation West, Gary, "Technical Bulletins: Drinking from a Fire Hydrant: The Fire Department's Role in Protecting the Public Water System" (2006). MTAS Publications: Technical Bulletins. https://trace.tennessee.edu/utk_mtastech/20 This Bulletin is brought to you for free and open access by the Municipal Technical Advisory Service (MTAS) at TRACE: Tennessee Research and Creative Exchange. It has been accepted for inclusion in MTAS Publications: Technical Bulletins by an authorized administrator of TRACE: Tennessee Research and Creative Exchange. For more information, please contact [email protected]. TECHNICAL bulletin 03-01-06 DRINKING FROM A FIRE HYDRANT: The Fire Department’s Role in Protecting the Public Water System Gary L. West, Fire Management Consultant A revised state regulation concerning fire in carrying out the state’s primary enforcement hydrants is causing concern for fire department responsibility under the Federal Safe Drinking leaders, providers of public water supplies, Water Act. -
Fire Service Features of Buildings and Fire Protection Systems
Fire Service Features of Buildings and Fire Protection Systems OSHA 3256-09R 2015 Occupational Safety and Health Act of 1970 “To assure safe and healthful working conditions for working men and women; by authorizing enforcement of the standards developed under the Act; by assisting and encouraging the States in their efforts to assure safe and healthful working conditions; by providing for research, information, education, and training in the field of occupational safety and health.” This publication provides a general overview of a particular standards- related topic. This publication does not alter or determine compliance responsibilities which are set forth in OSHA standards and the Occupational Safety and Health Act. Moreover, because interpretations and enforcement policy may change over time, for additional guidance on OSHA compliance requirements the reader should consult current administrative interpretations and decisions by the Occupational Safety and Health Review Commission and the courts. Material contained in this publication is in the public domain and may be reproduced, fully or partially, without permission. Source credit is requested but not required. This information will be made available to sensory-impaired individuals upon request. Voice phone: (202) 693-1999; teletypewriter (TTY) number: 1-877-889-5627. This guidance document is not a standard or regulation, and it creates no new legal obligations. It contains recommendations as well as descriptions of mandatory safety and health standards. The recommendations are advisory in nature, informational in content, and are intended to assist employers in providing a safe and healthful workplace. The Occupational Safety and Health Act requires employers to comply with safety and health standards and regulations promulgated by OSHA or by a state with an OSHA-approved state plan. -
A Preparedness Guide for Firefighters and Their Families
A Preparedness Guide for Firefighters and Their Families JULY 2019 A Preparedness Guide for Firefighters and Their Families July 2019 NOTE: This publication is a draft proof of concept for NWCG member agencies. The information contained is currently under review. All source sites and documents should be considered the authority on the information referenced; consult with the identified sources or with your agency human resources office for more information. Please provide input to the development of this publication through your agency program manager assigned to the NWCG Risk Management Committee (RMC). View the complete roster at https://www.nwcg.gov/committees/risk-management-committee/roster. A Preparedness Guide for Firefighters and Their Families provides honest information, resources, and conversation starters to give you, the firefighter, tools that will be helpful in preparing yourself and your family for realities of a career in wildland firefighting. This guide does not set any standards or mandates; rather, it is intended to provide you with helpful information to bridge the gap between “all is well” and managing the unexpected. This Guide will help firefighters and their families prepare for and respond to a realm of planned and unplanned situations in the world of wildland firefighting. The content, designed to help make informed decisions throughout a firefighting career, will cover: • hazards and risks associated with wildland firefighting; • discussing your wildland firefighter job with family and friends; • resources for peer support, individual counsel, planning, and response to death and serious injury; and • organizations that support wildland firefighters and their families. Preparing yourself and your family for this exciting and, at times, dangerous work can be both challenging and rewarding. -
Wildland Fire Incident Management Field Guide
A publication of the National Wildfire Coordinating Group Wildland Fire Incident Management Field Guide PMS 210 April 2013 Wildland Fire Incident Management Field Guide April 2013 PMS 210 Sponsored for NWCG publication by the NWCG Operations and Workforce Development Committee. Comments regarding the content of this product should be directed to the Operations and Workforce Development Committee, contact and other information about this committee is located on the NWCG Web site at http://www.nwcg.gov. Questions and comments may also be emailed to [email protected]. This product is available electronically from the NWCG Web site at http://www.nwcg.gov. Previous editions: this product replaces PMS 410-1, Fireline Handbook, NWCG Handbook 3, March 2004. The National Wildfire Coordinating Group (NWCG) has approved the contents of this product for the guidance of its member agencies and is not responsible for the interpretation or use of this information by anyone else. NWCG’s intent is to specifically identify all copyrighted content used in NWCG products. All other NWCG information is in the public domain. Use of public domain information, including copying, is permitted. Use of NWCG information within another document is permitted, if NWCG information is accurately credited to the NWCG. The NWCG logo may not be used except on NWCG-authorized information. “National Wildfire Coordinating Group,” “NWCG,” and the NWCG logo are trademarks of the National Wildfire Coordinating Group. The use of trade, firm, or corporation names or trademarks in this product is for the information and convenience of the reader and does not constitute an endorsement by the National Wildfire Coordinating Group or its member agencies of any product or service to the exclusion of others that may be suitable. -
Chapter 2 Water Distribution Design and Construction Standards And
CHAPTER 2 WATER DISTRIBUTION DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS November 1998 Revised May 2007 Prepared by : City of Marysville Public Works / Community Development CITY OF MARYSVILLE DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS CHAPTER 2 - WATER DISTRIBUTION Page No. 2-000 Water 2-1 2-010 General 2-1 2-020 Design Standards 2-2 2-030 Connections to Existing Water Main 2-2 2-040 Service Interruption 2-3 2-050 A. Water System Materials 2-3 B. Main Line 2-4 C. Dead End Line 2-4 D. Flexible Gasketed Joints - D.I. 2-4 E. Fittings 2-5 F. Polyethylene Encasement 2-5 G. Minimum Cover 2-5 H. Couplings 2-5 I. Adapters 2-6 J. Bolts in Piping 2-6 2-060 Hydrants 2-6 A. Requirements 2-6 B. Hydrant Leads 2-6 C. Installation 2-6 D. Hydrant Spacing and Guidelines 2-7 2-070 Valves 2-10 A. Gate Valves 2-11 B. Butterfly Valves 2-11 C. Valve Boxes 2-11 D. Operating Valve Nut Extensions 2-11 E. Valve Marker Post 2-12 F. Check Valves 2-12 G. Air & Vacuum Release Valves 2-12 2-080 Pressure Reducing Stations and Pressure Reducing Valves 2-12 2-090 Service Connections 2-14 2-100 Steel Casing 2-16 2-110 Galvanized Iron Pipe 2-16 2-120 Blowoff Assembly 2-17 2-130 Concrete Bedding & Blocking 2-17 2-140 Joint Restraint 2-17 2-150 Backflow Prevention 2-18 1. Reduced Pressure Backflow Assembly with Detector 2. Double Check Valve Assembly 3. -
CHAPTER 17 FIRE DEPARTMENT SECTION 17-1 Fire Chief SECTION
CHAPTER 17 FIRE DEPARTMENT SECTION 17-1 Fire Chief SECTION 17-2 Fire Marshall SECTION 17-3 Salary. When and How Paid SECTION 17-4 Duties and Powers SECTION 17-5 Authority to Remove Poles, Wires, and Buildings. Limitations SECTION 17-6 Fire Department May blockade Street SECTION 17-7 Limits At Fire SECTION 17-8 Unlawful Interference with Officers, Apparatus, Water, etc. Penalty SECTION 17-9 Fire Hydrants, Parking Nearby SECTION 17-10 Fire Hydrants on Private Property SECTION 17-11 Use of Water SECTION 17-12 Theaters, Places of Public Assembly. Chief to Prescribe Rules SECTION 17-13 Combustibles SECTION 17-14 Right to Enter Premises SECTION 17-15 Dangerous and Defective Structures, Combustible Waste, Explosives, Storage of, Notice to Make Safe SECTION 17-16 Unoccupied Buildings SECTION 17-17 Investigation After Fire. Report SECTION 17-18 Wilfully or Negligently Causing Fire SECTION 17-19 Throwing Lighted Objects from Vehicle SECTION 17-20 Driving Over Fire Hose SECTION 17-21 Right of Way SECTION 17-22 Apparatus SECTION 17-23 Interference with Apparatus. Penalty SECTION 17-24 False Alarm. Penalty SECTION 17-25 False Alarm. Practice Runs SECTION 17-26 Open Burning SECTION 17-27 Knox Box SECTION 17-28 Traffic Control Preemption Equipment CHAPTER 17 FIRE Department SECTION 17-1. Fire Chief. The Mayor, with the consent of and approval of the City Council, shall appoint the Chief of the Fire Department. The City Manager shall initiate the recruitment process as determined by the City personnel policies. Volunteer firefighters will be part of the selection committee. The Fire Chief shall organize and direct the activities and staff to protect lives and property of the City. -
Fire Hydrant & Fire Water Supply Requirements
Chambers County Fire Marshal’s Office Fire Hydrant & Fire Water Requirements Fire Water Requirement: Chambers County Fire Code and International Fire Code, 2018 Edition, require approved fire water supplies for fire protection (Section 507). The inability of a proposed occupancy to provide adequate water and distribution systems for fire protection, as deemed necessary by the fire code official according to the hazards associated with the occupancy, shall constitute grounds to deny the issuance of a permit (Chambers County Fire Code, Exhibit A, Sec. 507.1.1). Fire Hydrants: 1. If you are in an area served by a water district or municipal services, fire hydrants are required if a 6” or larger main fronts any side of your property. In areas not served by a water district or municipal services, see the last section of this document, “Fire Water Supplies in Undeveloped Areas”. 2. The maximum distance from a fire hydrant to a building is 400’ per IFC 2018 507.5.1, with an allowable increase of up to 600’ for a building with an automatic sprinkler system. This distance should be determined “as a hose would lay”, and measured to the exterior portions of the building (perimeter of building). More than one hydrant may be necessary to meet this requirement. 3. Hydrants shall be located out of the collapse zone of a building (NFPA 24 2016 7.2.4). 4. Hydrants shall have unobstructed access (507.5.4). (ie., not blocked by fences, etc.) 5. A hydrant must be located within 100’ from an FDC. 6. The use of a hydrant must not require the blocking of main driveways or access into the facility. -
Fire Hydrant Inspection and Maintenance
Fire Hydrant Inspection and Maintenance City of Defiance Water Division November 24, 2009 This manual was developed by the City of Defiance Water Division with the assistance of the Fire Division and Engineering Division. This manual was adopted by action of the City of Defiance Board of Control on November 24, 2009. This manual is available online at www.cityofdefiance.com/water/reports.shtml 2 Table of Contents Background …………………………………………………………………………… 5 Scope ……………………………………………………………………………………. 5 Privately Owned Hydrants ………………………………………………………… 5 Guidance Manuals and Publications ……………………………………………. 5 Dynamics of Water …………………………………………………………………. 6 WATER HAMMER BROWN WATER Purpose and Uses of Fire Hydrants …………………………………………….. 6 FIRE SUPPRESSION LINE FLUSHING TESTING SYSTEM OTHER USES BACKFLOW PREVENTION REQUIREMENTS Notification to Water Division …………………………………………………… 7 PRIOR TO OPERATION AFTER OPERATION Dry Barrel Hydrants ………………………………………………………………… 7 DIAGRAM OF TYPICAL HYDRANT PARTS Storz Fittings …………………………………………………………………………. 9 Painting and Color Coding Fire Hydrants ……………………………………... 9 PURPOSE DEFIANCE HYDRANT COLORS FIRE FLOW COLOR CODES Hydrant Repairs and Maintenance ……………………………………………… 10 RESPONSIBILITY Installation of Hydrants …………………………………………………………… 10 RESPONSIBILITY FOR INSTALLATION HYDRANT EXTENSIONS INSPECTION OF NEW HYDRANTS GENERAL SPECIFICATION SHEET FOR HYDRANT INSTALLATION 3 Table of Contents (cont.) Routine Inspection …………………………………………………………………. 12 FREQUENCY PROCEDURE Fire Flow Testing ……………………………………………………………………. 14 PURPOSE -
Fire Flow and Hydrant Requirements
Fire Marshal’s Offices North Division South Division East Division 4755 SW Griffith Dr. 7401 SW Washo Court 320 Warner Milne Rd Beaverton, OR 97076 Tualatin, OR 97062 PO Box 351 (503)526-2469 (503)612-7000 Oregon City, OR 97045 Fax (503)526-2538 Fax (503)612-7003 (503)652-1365 Fax (503)657-7913 FIRE FLOW and FIRE HYDRANT REQUIREMENTS The fire code requires that every building site have adequate water for fire fighting. The amount of water necessary to fight a fire for a particular building is called the required fire flow (GPM). It is based on the type of construction, building size, and fire hazard of the occupancy. Available fire flow is the amount of water available at the hydrants. Applicable fire flow is the amount of water that the fire department can deliver at a fire without depleting its ability to respond to other emergencies. The applicable fire flow also describes the level of acceptable risk of loss that the fire district is willing to take. The required fire flow cannot exceed either the available or applicable fire flow (3000GPM). The following information is from the 1997 Edition of the Uniform Fire Code (UFC) Article 9 and Appendix III-A as amended by Tualatin Valley Fire and Rescue Fire Prevention Ordinance 99-01 Section X. This will help you determine numbers and placement of fire hydrants, and fire flow requirements for your project and document those requirements for the fire district and building department records. Oregon Structural Specialty Code 901.2 requires that the fire fighting water supplies be designed and installed in accordance with the UFC. -
Media Kit Vs1 DRAFT
Jan Brewer Arizona State Forestry Division Governor Office of the State Forester 1110 W. Washington St., Suite 100 Scott Hunt Phoenix, AZ 85007 State Forester (602) 771-1400 For Immediate Release Contact: Carrie Dennett, PIO Sept. 28, 2013 (602) 399-3078 State Forester Releases Yarnell Hill Accident Investigation Report PHOENIX, Ariz. – The Arizona State Forester today released the Yarnell Hill Fire Serious Accident Investigation Report, which analyzes the circumstances leading to the June 30 entrapment and deaths of 19 firefighters of the Granite Mountain Interagency Hotshot Crew. The report and accompanying documents are available at https://sites.google.com/site/yarnellreport/. The State of Arizona convened an accident investigation team July 3 to review the conditions and events leading to the tragedy. The investigation team visited the site of the accident, reviewed audio and video files, interviewed individuals associated with the incident, reviewed fire weather and behavior data, and examined available records and physical evidence. The resulting report contains the most complete information available about the accident. “Our mission was to find out what happened and to discern the facts surrounding this tragedy to the best of our ability,” said Jim Karels, investigation team lead and the State Forester for the Florida Forest Service. “We also hope this report facilitates learning within the wildland fire community in order to reduce the likelihood of repeating actions that contributed to the loss of life.” The 116-page report includes a fact-based narrative of the incident and offers the investigation team’s analysis, conclusions and recommendations. It also includes a discussion section that is meant to facilitate understanding and learning by exploring various perspectives and issues that arose during the investigation. -
Fire Master Plans for Commercial & Residential Development
Orange County Fire Authority Community Risk Reduction 1 Fire Authority Road, Building A, Irvine, CA 92602 www.ocfa.org 714-573-6100 Fire Master Plans for Commercial & Residential Development Guideline B-09 Serving the Cities of Aliso Viejo • Buena Park • Cypress • Dana Point • Garden Grove • Irvine • Laguna Hills • Laguna Niguel • Laguna Woods Lake Forest • La Palma • Los Alamitos • Mission Viejo • Rancho Santa Margarita • San Clemente • San Juan Capistrano Seal Beach • Santa Ana • Stanton • Tustin • Villa Park • Westminster • Yorba Linda • and Unincorporated Areas of Orange County Fire Master Plans for Commercial & Residential Development: B-09 February 23, 2021 Fire Master Plans for Commercial & Residential Development TABLE OF CONTENTS PURPOSE ....................................................................................................................... 2 SCOPE ............................................................................................................................ 2 Definitions................................................................................................................................ 2 SECTION 1: PLAN SUBMITTAL REQUIREMENTS ...................................................... 4 SECTION 2: FIRE ACCESS ROADWAYS ..................................................................... 5 Loading ................................................................................................................................... 5 Number Required ................................................................................................................... -
Water Tender and Engine Typing NWCG/NIMS/FIRESCOPE Changes November 2012
FIRESCOPE Task Force January 1, 2013 TO: California Fire Service CHARLES BUTLER, Chair Battalion Chief Los Angeles FD FROM: Kim Zagaris, Chief/California Emergency Management Agency, KIRK WELLS, Vice- Chair Battalion Chief, Orange Executive Coordinator/FIRESCOPE County Fire Authority BRAD DARBRO, Secretary RE: NWCG and NIMS Equipment Typing Changes Battalion Chief, Santa Clara County FD STEVE WINTER On June 5, 2008, the National Wildland Coordinating Group distributed a memorandum, detailing changes Battalion Chief Ventura County FD adopted to the national standards for the typing of engines and water tenders. This information was widely distributed to the California fire service, through the Regional and Area coordinators to ensure that the MIKE LOCOCO changes were universally known. Assistant Chief, Cal EMA, Fire and Rescue Branch Subsequent to this, it was determined by FIRESCOPE during the actions to revise the FIRESCOPE Field WOODY ENOS Division Chief, Santa Barbara Operations Guide (FOG), ICS 420-1, that some differences were noted to the ability of water tenders in County FD California to meet these standards. During several review sessions by the FIRESCOPE Task Force, DAVE STONE meetings of the Operations Team, and meetings of the Board of Directors, these differences were identified Assistant Chief, Los Angeles and noted by footnoted asterisk in the equipment typing charts within Chapter 13 of the 2012 FOG Guide. County FD SEAN FRALEY The decision by NWCG to split the typing of water tenders into Tactical and Support categories is based on Battalion Chief a sound rationale and further helps to define their roles between tactical/line functions and non- Kern County FD tactical/support functions.