Chief Constable of Derbyshire Constabulary Trading As EMSOU-FS
Total Page:16
File Type:pdf, Size:1020Kb
Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Chief Constable of Derbyshire Constabulary trading as EMSOU-FS Issue No: 035 Issue date: 19 July 2021 EMSOU Forensic Services Contact: Ms Louise Shaw Arrow Centre E-Mail: [email protected] 7683 Annesley Road Website: www.derbyshire.police.uk Hucknall Accredited to Nottinghamshire ISO/IEC 17025:2017 NG15 8AY Testing performed by the Organisation at the locations specified Locations covered by the organisation and their relevant activities Laboratory locations: Location details Activity Location code Address Local contact Forensic Analysis ARR Arrow Centre Ms Louise Shaw Annesley Road Hucknall E-Mail: [email protected] NG15 8AY Website: www.derbyshire.police.uk United Kingdom Address Local contact Forensic Analysis LEI Leicestershire Police HQ Ms Louise Shaw Enderby Leicester E-Mail: [email protected] LE19 2BX Website: www.derbyshire.police.uk Address Local contact Forensic Analysis DER Derbyshire Police HQ Ms Louise Shaw Butterley Hall Ripley E-Mail: [email protected] DE5 3RS Website: www.derbyshire.police.uk Address Local contact Forensic Analysis NOT Nottinghamshire Police HQ Ms Louise Shaw Sherwood Lodge Arnold E-Mail: [email protected] NG5 8PP Website: www.derbyshire.police.uk Address Local contact Forensic Analysis NOR Northamptonshire Police HQ Ms Louise Shaw Wootton Hall Northampton E-Mail: [email protected] NN4 0JQ Website: www.derbyshire.police.uk Assessment Manager: HM1 Page 1 of 14 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines -u po n - Thames, TW18 3HR, UK Chief Constable of Derbyshire Constabulary trading as EMSOU-FS 7683 Issue No: 035 Issue date: 19 July 2021 Accredited to ISO/IEC 17025:2017 Testing performed by the Organisation at the locations specified Location Location details Activity code Address Local contact Forensic Analysis LIN Lincolnshire Police HQ Ms Louise Shaw Deepdale Lane Nettleham E-Mail: [email protected] Lincoln Website: www.derbyshire.police.uk LN2 2LT Address Local contact Forensic Analysis DII Discrete location Ms Louise Shaw E-Mail: [email protected] Website: www.derbyshire.police.uk Assessment Manager: HM1 Page 2 of 14 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines -u po n - Thames, TW18 3HR, UK Chief Constable of Derbyshire Constabulary trading as EMSOU-FS 7683 Issue No: 035 Issue date: 19 July 2021 Accredited to ISO/IEC 17025:2017 Testing performed by the Organisation at the locations specified DETAIL OF ACCREDITATION Materials/Products tested Type of test/Properties Standard specifications/ Location measured/Range of Equipment/Techniques used Code measurement Forensic Testing The organisation has demonstrated adherence to the relevant requirements of the Forensic Science Regulators Code of Practice and Conduct in relation to their Forensic Activities BODY FLUIDS and Forensic Analysis TISSUES Non-porous materials and Recovery and preparation, Documented in-house method ARR paper items (excluding including for contingency (FS-TP-04) using: clothing) purposes, for subsequent DNA - Swabs and swabbing analysis by an ISO/IEC 17025 accredited laboratory of the following, from previously identified / indicated suspected blood stains (excludes searching) - Blood Presumptive testing for blood Documented in-house method ARR via detection of: (FS-WI-18) using: - Peroxidase KM (Kastle Mayer) Any Material Recovery and preparation, Documented In-House Methods ARR including for contingency (FS-TP-04) using: purposes, for subsequent DNA - Swabs and swabbing analysis by an ISO/IEC 17025 accredited laboratory of the following from searched materials: - Cellular material Assessment Manager: HM1 Page 3 of 14 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines -u po n - Thames, TW18 3HR, UK Chief Constable of Derbyshire Constabulary trading as EMSOU-FS 7683 Issue No: 035 Issue date: 19 July 2021 Accredited to ISO/IEC 17025:2017 Testing performed by the Organisation at the locations specified Materials/Products tested Type of test/Properties Standard specifications/ Location measured/Range of Equipment/Techniques used Code measurement DRUGS (and materials Forensic Analysis (cont’d) suspected of containing drugs) Legal classification of Documented in-house method ARR controlled drugs (Misuse of (FS-TP-201 and FS-TP-205) Drugs Act 1971) using GCMS Identification of; - Amphetamine - Cocaine - Delta-9-THC - Diazepam - Dihydrocodeine - Heroin - Ketamine - Methadone - Methylamphetamine - Methylenedioxymethyl amphetamine (MDMA) - Methylethylcathinone (MEC) - Methylmethcathinone (MMC) - Methylone (MDMC) - Sildenafil - 5F-AKB48 Identification of additives and Documented in-house method ARR diluents commonly associated (FS-TP-201 and FS-TP-205) with drugs; using GCMS - Benzocaine - Caffeine - Ibuprofen - Lidocaine - Paracetamol - Phenacetin - Tetramisole Quantification of; Documented in-house method ARR - Amphetamine (FS-TP-201 and FS-TP-203) - Cocaine using HPLC - Heroin - Methylenedioxymethyl amphetamine (MDMA) Assessment Manager: HM1 Page 4 of 14 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines -u po n - Thames, TW18 3HR, UK Chief Constable of Derbyshire Constabulary trading as EMSOU-FS 7683 Issue No: 035 Issue date: 19 July 2021 Accredited to ISO/IEC 17025:2017 Testing performed by the Organisation at the locations specified Materials/Products tested Type of test/Properties Standard specifications/ Location measured/Range of Equipment/Techniques used Code measurement MARKS AND Forensic Analysis (cont’d) IMPRESSIONS Fingermarks Enhancement of fingermarks Documented In-House Methods ARR Any material which is and palm marks using chemical enhancement and capable of retaining friction lighting techniques (method ridge marks numbers provided in brackets) : - ESDA (FS/TP/306) - Acid Treatments (Ethanol formulation) : Acid Black 1, Acid Violet 17, Acid Yellow 7 (FS/TP/305) - Cyanoacrylate (CNA) Fuming (FS/TP/300) - Basic Yellow 40 (BY40) (Ethanol formulation)(FS/TP/304) - Ninhydrin (FS/TP/302) - Physical Developer (FS/TP/303) - Liquid Powder Suspension (Iron Oxide, Carbon Black, Titanium Oxide) (FS/TP/310) - Solvent Black 3 (FS/TP/322) - 1,2-Indandione (FS/TP/324) Documented In-House Methods ARR using lighting techniques - White Light and Filtered Sources (FS/TP/312) - High Energy Light Sources (FS/TP/312) Crimelites UV (λ350-380nm) Violet (λ395-425nm) Blue (λ420-470nm) Blue/Green (λ445- 510nm) Green (λ480-560nm) Orange (λ570-610nm) Assessment Manager: HM1 Page 5 of 14 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines -u po n - Thames, TW18 3HR, UK Chief Constable of Derbyshire Constabulary trading as EMSOU-FS 7683 Issue No: 035 Issue date: 19 July 2021 Accredited to ISO/IEC 17025:2017 Testing performed by the Organisation at the locations specified Materials/Products tested Type of test/Properties Standard specifications/ Location measured/Range of Equipment/Techniques used Code measurement MARKS AND Forensic Analysis (cont’d) IMPRESSIONS (cont’d) Documented In-House Methods ARR for imaging / digital capture (FS/TP/307) - DCS Developed fingerprint marks Determination of the presence Documented In-House methods ARR of friction ridge characteristics using visual examination for the purpose of subsequent (FS/TP/308) comparison Fingermark and palm mark Visual analysis, comparison Documented in-house methods ARR friction ridge detail and evaluation of recovered (FS-TP-500) using visual friction ridge detail with finger, examination, low power thumb and palm from: magnification and automated • Known inked Tenprint fingerprint recognition system sets IDENT 1. • Known electronic Tenprint sets Fingermark and palm mark Visual analysis, comparison Documented in-house methods ARR friction ridge detail and evaluation of recovered (FS-TP-505) using visual friction ridge detail with finger, examination, low power thumb and palm from: magnification, comparators, • Known inked Tenprint dimensional measurements and sets reference database (AFIS) • Known electronic Tenprint sets Opinion and Interpretation Documented in-house methods ARR The evaluation of matching using: features between marks to • Personal experience determine the attribution of the • Databases target mark Assessment Manager: HM1 Page 6 of 14 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines -u po n - Thames, TW18 3HR, UK Chief Constable of Derbyshire Constabulary trading as EMSOU-FS 7683 Issue No: 035 Issue date: 19 July 2021 Accredited to ISO/IEC 17025:2017 Testing performed by the Organisation at the locations specified Materials/Products tested Type of test/Properties Standard specifications/ Location measured/Range of Equipment/Techniques used Code measurement DIGITAL DEVICES AND Forensic Analysis DATA Computers and digital Physical capture and Documented in-house method(s) LEI,DER storage devices preservation of data (FS/TP/800 / DER-TP-800) using: - Hard disk drives - EnCase - Solid state drives - FTK Imager - Memory cards - Tableau Hardware - USB flash drives Forensic Write Blockers - Compact discs - Tableau TX1 (LEI only) - Digital