IBM Power 575 Supercomputing Node

Total Page:16

File Type:pdf, Size:1020Kb

IBM Power 575 Supercomputing Node Extreme performance supercomputer building blocks IBM Power 575 supercomputing node with specialized software from IBM, this system is designed to perform and rep- resents the latest Power technology available. Ideal workloads for this system include high performance computing (HPC) applications such as weather and climate modeling, computational chem- istry, physics, computer-aided engineer- ing, computational fluid dynamics and petroleum exploration that require highly Power 575 node intense computations where the work- load is aligned with parallel processing The IBM Power™ 575 supercomputing methodologies. IBM has long been a Highlights node is designed for organizations that leader in these application areas and, require a highly scalable system with ■ Optimized for running large, with this system, enables you to inno- extreme parallel processing perform- highly parallel computationally- vate and mold the future. ance and dense, modular packaging. intensive workloads and Use it in clustered configurations of as algorithms Densely packing up to 448 POWER6™ few as 32 processor cores or in world- processor cores per frame, each one class supercomputer configurations of ■ Application affinity for weather running at 4.7 GHz with innovative thousands of processors. Combined and climate modeling, compu- cooling features, the 32-core tational chemistry, physics, computer-aided engineering, computational fluid dynamics and petroleum exploration Power 575 supercomputing node is the Power 575 is estimated to achieve solve the world’s greatest problems. designed for speed and tuned for per- over five times the GFLOPS per frame Starting with the lightning fast 4.7 GHz formance. Available in increments of as its predecessor with POWER5+™ processor, adding the ultra dense pack- 2U building blocks, hundreds of these technology.1 The radical new approach aging of 32 cores in a 2U node and nodes can be clustered together to to HPC represented by the Power 575 injected with a chilled coolant to enable tackle the world’s greatest problems. system marks another step in the evo- peak performance, this system is a Supported by up to 3.5 TB of memory lution of modular clusters designed to supersonic race car on the IT highway. per frame and super fast interconnects, Feature Benefits Extreme POWER6 performance ● Ability to solve problems faster or tackle even larger problems ● Ability to respond to increasingly complex challenges ● Ability to inject more variables into equations to improve modeling accuracy Innovative modular design ● Ability to buy the exact size system required ● Ability to easily grow the system over time ● Greater packaging density requires less floor space thereby reducing operational costs Radical energy-efficient cooling ● Enables greater performance with a smaller footprint technology ● Supports environmental goals by optimizing energy usage ● Reduces operational costs Ultra-scalable ● Allows for extreme performance ● Enables centralized management of multiple interconnected systems Mainframe-inspired reliability ● Improved assurance that work will not be interrupted ● Better customer satisfaction due to reliable and predictable operations ● Faster repair when required due to sophisticated system diagnostics Extensive software support ● Ability to select the right application to meet your needs Extreme POWER6 performance achieved with 448 processor cores in a all 32 POWER6 processor cores and With years of patent leadership and single footprint (fourteen 32-core nodes with the aid of pumping devices decades of IT experience, it is no sur- packaged in a single 42U 24-inch mounted in the base of the frame, prise that IBM technology is the system frame). Nodes can be config- direct chilled coolant over the proces- industry-leader for processor perform- ured with or without support for internal sors to keep them running at peak ance. The ultra-high frequency of and/or external I/O devices. Compared intensity. POWER6 575 technology provides a to its POWER5+ predecessor, the superscalar design with over twice the Power 575 node delivers twice the In addition, ambient air is directed clock speed and twice the memory packaging density and thereby enables across the remaining components bandwidth of previous IBM generations. substantially higher sustained through- and the entire air cooling load is POWER6 processors feature enhanced put for high performance computing reduced by the integrated rear door simultaneous multithreading with (HPC) applications. heat exchanger located at the rear of support for Hardware Decimal the system. Inside, sealed tubes filled Floating-Point and an AltiVec™ SIMD The highly efficient DC power distribu- with chilled water absorb the heat gen- accelerator for added performance. tion module is integrated into the erated in a fully populated rack and hinged lid of the node. This innovative carry it away so it is not released into Arrange 32 of these high-powered power system relies on embedded cir- the datacenter. Similar to the optional engines together in a single slim-line cuitry rather than external wiring, pro- IBM Rear Door Heat eXchanger for rack node with 256 GB of memory and a viding more reliable and efficient power installations, this unit is now integrated dual 2-port 4X host channel adapter, distribution. This power module into the same cooling loop as the rest and you have a system designed for includes precision intelligent monitoring of the system and standard for all speed. One Power 575 node is esti- and control functions that are designed Power 575 systems. mated to achieve over 600 GFLOPS, to help assure power delivery is opti- 4.95 times the performance of its pred- mized at all times and provides alert Years in development by IBM, the ecessor with POWER5+ technology.3 data to the node service processor in industry’s leader in IT patents, this revo- the case of a fault. lutionary dual partnership of cold- Innovative modular design plates and Rear Door Heat eXchanger Mounted in a sleek 2U enclosure, the Radical energy-efficient cooling are integrated into the advanced, inno- Power 575 supercomputing node fea- technology vative design of the Power 575 system. tures innovative, elegant design and With the introduction of the Power 575, Leveraging existing chilled water supply packaging that facilitates ease of serv- IBM is announcing the availability of for air conditioning systems already ice and flexibility. Few systems can new water cooling technology that can located in a majority of datacenters match the extraordinary density help reduce related energy costs. around the globe, this system is Cold-plates are directly mounted over designed to reduce server heat emis- Mainframe-inspired reliability features arrangement. Support for 200v to 240v, sions by up to 80 percent (versus a Among the world-class RAS capabilities 380v to 415v, and 480v three phase comparable air cooled system providing provided in the Power 575 are a power inputs allow clients to enjoy equivalent system performance).4 sophisticated service processor; hot- reduced facility equipment cost and plug, hot-swappable and redundant help improve energy efficiency. The abil- Scale-up or scale-out easily components; IBM Chipkill™ ECC and ity of the 575 to tolerate power distur- Power 575 supercomputing nodes can bit-steering memory; First Failure Data bances is exceptional in comparison to be easily scaled within the system Capture mechanisms; and dynamic most other computing equipment. frame or replicated within the cluster to deallocation of system components. meet growing workload requirements. These capabilities help to increase sys- Extensive software support Equipped with 32 GB of memory in its tem availability and allow more work to The Power 575 supercomputing node minimum configuration, each node be processed with less operational dis- can run both AIX® and Linux® operat- can scale-up to 256 GB. Two hot- ruption. New with POWER6 technology, ing systems simultaneously to provide swappable disk drives allow disk Processor Instruction Retry provides for the flexibility to support a full range of storage capacity from 73.4 GB to the continuous monitoring of processor HPC applications as required. AIX is an 293.6 GB per node. For even greater status with the capability to restart a industrial-strength UNIX® operating disk capacity, the optional 12X I/O processor if certain errors are detected. system (OS) tuned for application per- drawer supports up to 16 Ultra3 SCSI If required, workloads can be redirected formance and delivers exceptional disk bays or the optional 12S expan- to alternate processors, all without dis- scalability for clusters of all sizes. Web- sion drawer for up to 12 hot-swap SAS ruption to application execution. based remote management tools give drives per drawer. administrators centralized control of the The Power 575 system includes struc- system, enabling them to monitor key A Power 575 cluster can scale-out tural elements at the frame level to help resources, including adapter and net- easily and cost-effectively as workload ensure outstanding availability even in work availability, file system status and requirements increase. Each system the event of facility power problems. processor workload. frame accommodates up to 14 nodes. The 575 system frame uses IBM’s Organizations can add system frames leading-edge rack level distributed The 575 node also supports the Linux to build a system cluster with hundreds power conversion architecture to OS allowing a broad choice of applica- of nodes and thousands
Recommended publications
  • Wind Rose Data Comes in the Form >200,000 Wind Rose Images
    Making Wind Speed and Direction Maps Rich Stromberg Alaska Energy Authority [email protected]/907-771-3053 6/30/2011 Wind Direction Maps 1 Wind rose data comes in the form of >200,000 wind rose images across Alaska 6/30/2011 Wind Direction Maps 2 Wind rose data is quantified in very large Excel™ spreadsheets for each region of the state • Fields: X Y X_1 Y_1 FILE FREQ1 FREQ2 FREQ3 FREQ4 FREQ5 FREQ6 FREQ7 FREQ8 FREQ9 FREQ10 FREQ11 FREQ12 FREQ13 FREQ14 FREQ15 FREQ16 SPEED1 SPEED2 SPEED3 SPEED4 SPEED5 SPEED6 SPEED7 SPEED8 SPEED9 SPEED10 SPEED11 SPEED12 SPEED13 SPEED14 SPEED15 SPEED16 POWER1 POWER2 POWER3 POWER4 POWER5 POWER6 POWER7 POWER8 POWER9 POWER10 POWER11 POWER12 POWER13 POWER14 POWER15 POWER16 WEIBC1 WEIBC2 WEIBC3 WEIBC4 WEIBC5 WEIBC6 WEIBC7 WEIBC8 WEIBC9 WEIBC10 WEIBC11 WEIBC12 WEIBC13 WEIBC14 WEIBC15 WEIBC16 WEIBK1 WEIBK2 WEIBK3 WEIBK4 WEIBK5 WEIBK6 WEIBK7 WEIBK8 WEIBK9 WEIBK10 WEIBK11 WEIBK12 WEIBK13 WEIBK14 WEIBK15 WEIBK16 6/30/2011 Wind Direction Maps 3 Data set is thinned down to wind power density • Fields: X Y • POWER1 POWER2 POWER3 POWER4 POWER5 POWER6 POWER7 POWER8 POWER9 POWER10 POWER11 POWER12 POWER13 POWER14 POWER15 POWER16 • Power1 is the wind power density coming from the north (0 degrees). Power 2 is wind power from 22.5 deg.,…Power 9 is south (180 deg.), etc… 6/30/2011 Wind Direction Maps 4 Spreadsheet calculations X Y POWER1 POWER2 POWER3 POWER4 POWER5 POWER6 POWER7 POWER8 POWER9 POWER10 POWER11 POWER12 POWER13 POWER14 POWER15 POWER16 Max Wind Dir Prim 2nd Wind Dir Sec -132.7365 54.4833 0.643 0.767 1.911 4.083
    [Show full text]
  • POWER® Processor-Based Systems
    IBM® Power® Systems RAS Introduction to IBM® Power® Reliability, Availability, and Serviceability for POWER9® processor-based systems using IBM PowerVM™ With Updates covering the latest 4+ Socket Power10 processor-based systems IBM Systems Group Daniel Henderson, Irving Baysah Trademarks, Copyrights, Notices and Acknowledgements Trademarks IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. These and other IBM trademarked terms are marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml The following terms are trademarks of the International Business Machines Corporation in the United States, other countries, or both: Active AIX® POWER® POWER Power Power Systems Memory™ Hypervisor™ Systems™ Software™ Power® POWER POWER7 POWER8™ POWER® PowerLinux™ 7® +™ POWER® PowerHA® POWER6 ® PowerVM System System PowerVC™ POWER Power Architecture™ ® x® z® Hypervisor™ Additional Trademarks may be identified in the body of this document. Other company, product, or service names may be trademarks or service marks of others. Notices The last page of this document contains copyright information, important notices, and other information. Acknowledgements While this whitepaper has two principal authors/editors it is the culmination of the work of a number of different subject matter experts within IBM who contributed ideas, detailed technical information, and the occasional photograph and section of description.
    [Show full text]
  • Openpower AI CERN V1.Pdf
    Moore’s Law Processor Technology Firmware / OS Linux Accelerator sSoftware OpenStack Storage Network ... Price/Performance POWER8 2000 2020 DRAM Memory Chips Buffer Power8: Up to 12 Cores, up to 96 Threads L1, L2, L3 + L4 Caches Up to 1 TB per socket https://www.ibm.com/blogs/syst Up to 230 GB/s sustained memory ems/power-systems- openpower-enable- bandwidth acceleration/ System System Memory Memory 115 GB/s 115 GB/s POWER8 POWER8 CPU CPU NVLink NVLink 80 GB/s 80 GB/s P100 P100 P100 P100 GPU GPU GPU GPU GPU GPU GPU GPU Memory Memory Memory Memory GPU PCIe CPU 16 GB/s System bottleneck Graphics System Memory Memory IBM aDVantage: data communication and GPU performance POWER8 + 78 ms Tesla P100+NVLink x86 baseD 170 ms GPU system ImageNet / Alexnet: Minibatch size = 128 ADD: Coherent Accelerator Processor Interface (CAPI) FPGA CAPP PCIe POWER8 Processor ...FPGAs, networking, memory... Typical I/O MoDel Flow Copy or Pin MMIO Notify Poll / Int Copy or Unpin Ret. From DD DD Call Acceleration Source Data Accelerator Completion Result Data Completion Flow with a Coherent MoDel ShareD Mem. ShareD Memory Acceleration Notify Accelerator Completion Focus on Enterprise Scale-Up Focus on Scale-Out and Enterprise Future Technology and Performance DriVen Cost and Acceleration DriVen Partner Chip POWER6 Architecture POWER7 Architecture POWER8 Architecture POWER9 Architecture POWER10 POWER8/9 2007 2008 2010 2012 2014 2016 2017 TBD 2018 - 20 2020+ POWER6 POWER6+ POWER7 POWER7+ POWER8 POWER8 P9 SO P9 SU P9 SO 2 cores 2 cores 8 cores 8 cores 12 cores w/ NVLink
    [Show full text]
  • From Blue Gene to Cell Power.Org Moscow, JSCC Technical Day November 30, 2005
    IBM eServer pSeries™ From Blue Gene to Cell Power.org Moscow, JSCC Technical Day November 30, 2005 Dr. Luigi Brochard IBM Distinguished Engineer Deep Computing Architect [email protected] © 2004 IBM Corporation IBM eServer pSeries™ Technology Trends As frequency increase is limited due to power limitation Dual core is a way to : 2 x Peak Performance per chip (and per cycle) But at the expense of frequency (around 20% down) Another way is to increase Flop/cycle © 2004 IBM Corporation IBM eServer pSeries™ IBM innovations POWER : FMA in 1990 with POWER: 2 Flop/cycle/chip Double FMA in 1992 with POWER2 : 4 Flop/cycle/chip Dual core in 2001 with POWER4: 8 Flop/cycle/chip Quadruple core modules in Oct 2005 with POWER5: 16 Flop/cycle/module PowerPC: VMX in 2003 with ppc970FX : 8 Flops/cycle/core, 32bit only Dual VMX+ FMA with pp970MP in 1Q06 Blue Gene: Low frequency , system on a chip, tight integration of thousands of cpus Cell : 8 SIMD units and a ppc970 core on a chip : 64 Flop/cycle/chip © 2004 IBM Corporation IBM eServer pSeries™ Technology Trends As needs diversify, systems are heterogeneous and distributed GRID technologies are an essential part to create cooperative environments based on standards © 2004 IBM Corporation IBM eServer pSeries™ IBM innovations IBM is : a sponsor of Globus Alliances contributing to Globus Tool Kit open souce a founding member of Globus Consortium IBM is extending its products Global file systems : – Multi platform and multi cluster GPFS Meta schedulers : – Multi platform
    [Show full text]
  • Progress Codes
    Power Systems Progress codes Power Systems Progress codes Note Before using this information and the product it supports, read the information in “Notices,” on page 109, “Safety notices” on page v, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. This edition applies to IBM Power Systems™ servers that contain the POWER6® processor and to all associated models. © Copyright IBM Corporation 2007, 2009. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Safety notices ............v Chapter 13. (CAxx) Partition firmware progress codes ...........79 Chapter 1. Progress codes overview . 1 Chapter 14. (CF00) Linux kernel boot Chapter 2. AIX IPL progress codes . 3 progress codes ...........91 Chapter 3. AIX diagnostic load Chapter 15. (D1xx) Service processor progress indicators .........29 firmware progress codes .......93 Chapter 4. Dump progress indicators Chapter 16. (D1xx) Service processor (dump status codes) .........33 status progress codes ........95 Chapter 5. AIX crash progress codes Chapter 17. (D1xx) Service processor (category 1) ............35 dump status progress codes .....97 Chapter 6. AIX crash progress codes Chapter 18. (D1xx) Platform dump (category 2) ............37 status progress codes .......101 Chapter 7. AIX crash progress codes Chapter 19. (D2xx) Partition status (category 3) ............39 progress codes ..........103 Chapter 8. (C1xx) Service processor Chapter 20. (D6xx) General status progress codes ...........41 progress codes ..........105 Chapter 9. (C2xx) Virtual service Chapter 21. (D9xx) General status processor progress codes ......63 progress codes ..........107 Chapter 10. (C3xx, C5xx, C6xx) IPL Appendix. Notices .........109 status progress codes ........67 Trademarks ..............110 Electronic emission notices .........111 Chapter 11.
    [Show full text]
  • IBM Power Roadmap
    POWER6™ Processor and Systems Jim McInnes [email protected] Compiler Optimization IBM Canada Toronto Software Lab © 2007 IBM Corporation All statements regarding IBM future directions and intent are subject to change or withdrawal without notice and represent goals and objectives only Role .I am a Technical leader in the Compiler Optimization Team . Focal point to the hardware development team . Member of the Power ISA Architecture Board .For each new microarchitecture I . help direct the design toward helpful features . Design and deliver specific compiler optimizations to enable hardware exploitation 2 IBM POWER6 Overview © 2007 IBM Corporation All statements regarding IBM future directions and intent are subject to change or withdrawal without notice and represent goals and objectives only POWER5 Chip Overview High frequency dual-core chip . 8 execution units 2LS, 2FP, 2FX, 1BR, 1CR . 1.9MB on-chip shared L2 – point of coherency, 3 slices . On-chip L3 directory and controller . On-chip memory controller Technology & Chip Stats . 130nm lithography, Cu, SOI . 276M transistors, 389 mm2 . I/Os: 2313 signal, 3057 Power/Gnd 3 IBM POWER6 Overview © 2007 IBM Corporation All statements regarding IBM future directions and intent are subject to change or withdrawal without notice and represent goals and objectives only POWER6 Chip Overview SDU RU Ultra-high frequency dual-core chip IFU FXU . 8 execution units L2 Core0 VMX L2 2LS, 2FP, 2FX, 1BR, 1VMX QUAD LSU FPU QUAD . 2 x 4MB on-chip L2 – point of L3 coherency, 4 quads L2 CNTL CNTL . On-chip L3 directory and controller . Two on-chip memory controllers M FBC GXC M Technology & Chip stats C C .
    [Show full text]
  • Power Architecture® ISA 2.06 Stride N Prefetch Engines to Boost Application's Performance
    Power Architecture® ISA 2.06 Stride N prefetch Engines to boost Application's performance History of IBM POWER architecture: POWER stands for Performance Optimization with Enhanced RISC. Power architecture is synonymous with performance. Introduced by IBM in 1991, POWER1 was a superscalar design that implemented register renaming andout-of-order execution. In Power2, additional FP unit and caches were added to boost performance. In 1996 IBM released successor of the POWER2 called P2SC (POWER2 Super chip), which is a single chip implementation of POWER2. P2SC is used to power the 30-node IBM Deep Blue supercomputer that beat world Chess Champion Garry Kasparov at chess in 1997. Power3, first 64 bit SMP, featured a data prefetch engine, non-blocking interleaved data cache, dual floating point execution units, and many other goodies. Power3 also unified the PowerPC and POWER Instruction set and was used in IBM's RS/6000 servers. The POWER3-II reimplemented POWER3 using copper interconnects, delivering double the performance at about the same price. Power4 was the first Gigahertz dual core processor launched in 2001 which was awarded the MicroProcessor Technology Award in recognition of its innovations and technology exploitation. Power5 came in with symmetric multi threading (SMT) feature to further increase application's performance. In 2004, IBM with 15 other companies founded Power.org. Power.org released the Power ISA v2.03 in September 2006, Power ISA v.2.04 in June 2007 and Power ISA v.2.05 with many advanced features such as VMX, virtualization, variable length encoding, hyper visor functionality, logical partitioning, virtual page handling, Decimal Floating point and so on which further boosted the architecture leadership in the market place and POWER5+, Cell, POWER6, PA6T, Titan are various compliant cores.
    [Show full text]
  • POWER8: the First Openpower Processor
    POWER8: The first OpenPOWER processor Dr. Michael Gschwind Senior Technical Staff Member & Senior Manager IBM Power Systems #OpenPOWERSummit Join the conversation at #OpenPOWERSummit 1 OpenPOWER is about choice in large-scale data centers The choice to The choice to The choice to differentiate innovate grow . build workload • collaborative • delivered system optimized innovation in open performance solutions ecosystem • new capabilities . use best-of- • with open instead of breed interfaces technology scaling components from an open ecosystem Join the conversation at #OpenPOWERSummit Why Power and Why Now? . Power is optimized for server workloads . Power8 was optimized to simplify application porting . Power8 includes CAPI, the Coherent Accelerator Processor Interconnect • Building on a long history of IBM workload acceleration Join the conversation at #OpenPOWERSummit POWER8 Processor Cores • 12 cores (SMT8) 96 threads per chip • 2X internal data flows/queues • 64K data cache, 32K instruction cache Caches • 512 KB SRAM L2 / core • 96 MB eDRAM shared L3 • Up to 128 MB eDRAM L4 (off-chip) Accelerators • Crypto & memory expansion • Transactional Memory • VMM assist • Data Move / VM Mobility • Coherent Accelerator Processor Interface (CAPI) Join the conversation at #OpenPOWERSummit 4 POWER8 Core •Up to eight hardware threads per core (SMT8) •8 dispatch •10 issue •16 execution pipes: •2 FXU, 2 LSU, 2 LU, 4 FPU, 2 VMX, 1 Crypto, 1 DFU, 1 CR, 1 BR •Larger Issue queues (4 x 16-entry) •Larger global completion, Load/Store reorder queue •Improved branch prediction •Improved unaligned storage access •Improved data prefetch Join the conversation at #OpenPOWERSummit 5 POWER8 Architecture . High-performance LE support – Foundation for a new ecosystem . Organic application growth Power evolution – Instruction Fusion 1600 PowerPC .
    [Show full text]
  • IBM System P 570 with New POWER6 Processor Increases Bandwidth and Capacity
    IBM United States Announcement 107-288, dated May 22, 2007 IBM System p 570 with new POWER6 processor increases bandwidth and capacity Description .................................................2 At a glance Statement of general direction .................12 Publications ............................................. 14 The System p 570 mid-range server is designed to deliver outstanding Services ...................................................16 price/performance, mainframe-inspired reliability and availability Technical information ...............................16 features, flexible capacity upgrades, and innovative virtualization IBM Electronic Services ...........................25 technologies. The System p 570 features: Terms and conditions .............................. 26 • Powerful new IBM POWER6 processors Prices .......................................................29 • 2-, 4-, 8-, 12-, and 16-core configurations Order now ................................................42 • Three processor frequency choices: 3.5 GHz, 4.2 GHz, and 4.7 GHz • Up to 768 GB of DDR2 memory • Memory frequencies of up to 667 MHz • Six Serial Attached SCSI (SAS) DASD drives per enclosure (24 max per system) • Up to 7.2 TB of internal disk storage • Modular rack-mount design with one to four CEC enclosures • Seven I/O expansion slots per enclosure (28 max per system) • Dynamic logical partitions — up to 160 per system (optional) • Innovative on demand features for both processors and memory • Integrated Virtual Ethernet ports — select from 1 Gb and 10 Gb options For ordering, contact: Your IBM representative or the Americas Call Centers at 800-IBM-CALL Reference: YE001 Overview The innovative System p™ 570 with POWER6™ dual-core processors is a 2- to 16-core SMP, rack-mounted server. The new POWER6 processors in this server are 64-bit, dual cores on a single chip module, with 32 MB of L3 cache, 8 MB of L2 cache, and 12 DDR2 memory DIMM slots.
    [Show full text]
  • Power8 Quser Mspl Nov 2015 Handout
    IBM Power Systems Power Systems Hardware: Today and Tomorrow November 2015 Mark Olson [email protected] © 2015 IBM Corporation IBM Power Systems POWER8 Chip © 2015 IBM Corporation IBM Power Systems Processor Technology Roadmap POWER11 Or whatever it is POWER10 named Or whatever it is POWER9 named Or whatever it is named POWER7 POWER8 POWER6 45 nm 22 nm POWER5 65 nm 130 nm POWER4 90 nm 180 nm 130 nm 2001 2004 2007 2010 2014 Future 3 © 2015 IBM Corporation IBM Power Systems Processor Chip Comparisons POWER5 POWER6 POWER7 POWER7+ POWER8 2004 2007 2010 2012 45nm SOI 32nm SOI 22nm SOI Technology 130nm SOI 65nm SOI eDRAM eDRAM eDRAM Compute Cores 2 2 8 8 12 Threads SMT2 SMT2 SMT4 SMT4 SMT8 Caching On-chip 1.9MB (L2) 8MB (L2) 2 + 32MB (L2+3) 2 + 80MB (L2+3) 6 + 96MB (L2+3) Off-chip 36MB (L3) 32MB (L3) None None 128MB (L4) Bandwidth Sust. Mem. 15GB/s 30GB/s 100GB/s 100GB/s 230GB/s Peak I/O 6GB/s 20GB/s 40GB/s 40GB/s 96GB/s 4 © 2015 IBM Corporation IBM Power Systems Processor Designs POWER5+ POWER6 POWER7 POWER7+ POWER8 Max cores 4 2 8 8 12 Technology 90nm 65nm 45nm 32nm 22nm Size 245 mm2 341 mm2 567 mm2 567 mm2 650 mm2 * Transistors 276 M 790 M 1.2 B 2.1 B 4.2 B * 1.9 4 - 5 3 – 4 Up to 4.4 Up to 4.1 Frequencies GHz GHz GHz GHz GHz ** SMT (threads) 2 2 4 4 8 L2 Cache 1.9MB Shared 4MB / Core 256KB / core 256KB / core 512KB/core 4MB / Core 10MB / Core 8MB / Core L3 Cache 36MB 32MB On chip On chip On chip L4 Cache -- -- -- -- Up to 128MB Bandwidth Sust memory 15GB/s 30GB/s 100GB/s 100GB/s 230GB/s Peak I/O 6GB/s 20GB/s 40GB/s 40GB/s 96GB/s * with 12-core
    [Show full text]
  • Computer Architectures an Overview
    Computer Architectures An Overview PDF generated using the open source mwlib toolkit. See http://code.pediapress.com/ for more information. PDF generated at: Sat, 25 Feb 2012 22:35:32 UTC Contents Articles Microarchitecture 1 x86 7 PowerPC 23 IBM POWER 33 MIPS architecture 39 SPARC 57 ARM architecture 65 DEC Alpha 80 AlphaStation 92 AlphaServer 95 Very long instruction word 103 Instruction-level parallelism 107 Explicitly parallel instruction computing 108 References Article Sources and Contributors 111 Image Sources, Licenses and Contributors 113 Article Licenses License 114 Microarchitecture 1 Microarchitecture In computer engineering, microarchitecture (sometimes abbreviated to µarch or uarch), also called computer organization, is the way a given instruction set architecture (ISA) is implemented on a processor. A given ISA may be implemented with different microarchitectures.[1] Implementations might vary due to different goals of a given design or due to shifts in technology.[2] Computer architecture is the combination of microarchitecture and instruction set design. Relation to instruction set architecture The ISA is roughly the same as the programming model of a processor as seen by an assembly language programmer or compiler writer. The ISA includes the execution model, processor registers, address and data formats among other things. The Intel Core microarchitecture microarchitecture includes the constituent parts of the processor and how these interconnect and interoperate to implement the ISA. The microarchitecture of a machine is usually represented as (more or less detailed) diagrams that describe the interconnections of the various microarchitectural elements of the machine, which may be everything from single gates and registers, to complete arithmetic logic units (ALU)s and even larger elements.
    [Show full text]
  • KVM on POWER7
    Developments in KVM on Power Paul Mackerras, IBM LTC OzLabs [email protected] Outline . Introduction . Little-endian support . OpenStack . Nested virtualization . Guest hotplug . Hardware error detection and recovery 2 21 October 2013 © 2013 IBM Introduction • We will be releasing POWER® machines with KVM – Announcement by Arvind Krishna, IBM executive • POWER8® processor disclosed at Hot Chips conference – 12 cores per chip, 8 threads per core – 96kB L1 cache, 512kB L2 cache, 8MB L3 cache per core on chip u u Guest Guest m host OS process m e e OS OS q host OS process q host OS process KVM Host Linux Kernel SAPPHIRE FSP POWER hardware 3 21 October 2013 © 2013 IBM Introduction • “Sapphire” firmware being developed for these machines – Team led by Ben Herrenschmidt – Successor to OPAL • Provides initialization and boot services for host OS – Load first-stage Linux kernel from flash – Probe the machine and set up device tree – Petitboot bootloader to load and run the host kernel (via kexec) • Provides low-level run-time services to host kernel – Communication with the service processor (FSP) • Console • Power and reboot control • Non-volatile memory • Time of day clock • Error logging facilities – Some low-level error detection and recovery services 4 21 October 2013 © 2013 IBM Little-endian Support • Modern POWER CPUs have a little-endian mode – Instructions and multi-byte data operands interpreted in little-endian byte order • Lowest-numbered byte is least significant, rather than most significant – “True” little endian, not address swizzling
    [Show full text]