Versette User’S Manual

Total Page:16

File Type:pdf, Size:1020Kb

Versette User’S Manual Thermo Scientific Versette User’s Manual D09888 Revision 2.3 March 28, 2011 Thermo Fisher Scientific Inc. provides this document to its customers with a product purchase to use in the product operation. This document is copyright protected and any reproduction of the whole or any part of this document is strictly prohibited, except with the written authorization of Thermo Fisher Scientific Inc. The contents of this document are subject to change without notice. All technical information in this document is for reference purposes only. System configurations and specifications in this document supersede all previous information received by the purchaser. Thermo Fisher Scientific Inc. makes no representations that this document is complete, accurate or error- free and assumes no responsibility and will not be liable for any errors, omissions, damage or loss that might result from any use of this document, even if the information in the document is followed properly. This document is not part of any sales contract between Thermo Fisher Scientific Inc. and a purchaser. This document shall in no way govern or modify any Terms and Conditions of Sale, which Terms and Conditions of Sale shall govern all conflicting information between the two documents. Release history: 21 December 2010, Rev. 1.9 Initial release. 6 January 2011, Rev. 2.0 17 January 2011, Rev. 2.1 - Added Cert. of Compliance. Updated SMC Calibration. 21 January 2011, Rev. 2.2 - Update to SMC Calibration. 28 March 2011, Rev. 2.3 - Update to Calibration sequences, and install of 2-stage system. For Research Use Only. Not for use in diagnostic procedures. PATENT PENDING © 2010-2011 Thermo Scientific Inc. All rights reserved. Declaration of Conformity Legal Identity: Thermo Fisher Scientific 81 Wyman Street Waltham, MA 02454 Authorized Representative: Thermo Fisher Scientific 22 Friars Drive Hudson, NH 03051 Equipment Identification Type of Equipment: Laboratory - Versette Automated Liquid Handler 650-01-BS, BASE TOWER Serial Numbers 1010 to 1500 We, Thermo Fisher Scientific, hereby declare that the devices mentioned above comply with the European Low Voltage Directive 2006/95/EC & 2004/108/EEC EMC Directive Common Technical Specifications EN55011 (2007) used for demonstration of EN61326-1 (2006) compliance: EN61000-3-2 (2000) + A2 (2005) EN61000-3-3 (1995) + A2 (2005) EN61010-1 (2001, 2nd ED.) Date of Validity: November 17, 2010 Name of Authorized Signatory: Michael Morrison Position Held in Company Operations Manager Location @ Signing Hudson, NH Signature: Thermo SCIENTIFIC WEEE Compliance This product is required to comply with the European Union’s Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96/EC. It is marked with the following symbol: Thermo Fisher Scientific has contracted with one or more recycling or disposal companies in each European Union (EU) Member State, and these companies should dispose of or recycle this product. Contact Thermo for further information on Thermo Fisher Scientific’s compliance with these Directives and the recyclers in your country. WEEE Konformität Dieses Produkt muss die EU Waste Electrical & Electronic Equipment (WEEE) Richtlinie 2002/96/EC erfüllen. Das Produkt ist durch folgendes Symbol gekennzeichnet: Thermo Fisher Scientific hat Vereinbarungen mit Verwertungs-/Entsorgungsfirmen in allen EU-Mitgliedsstaaten getroffen, damit dieses Produkt durch diese Firmen wiederverwertet oder entsorgt werden kann. Mehr Information über die Einhaltung dieser Anweisungen durch Thermo Fisher Scientific, über die Verwerter, und weitere Hinweise, die nützlich sind, um die Produkte zu identifizieren, die unter diese RoHS Anweisung fallen, bitte kontaktieren Sie Thermo für weitere Informationen. Thermo SCIENTIFIC Conformité DEEE Ce produit doit être conforme à la directive européenne (2002/96/EC) des Déchets d'Equipements Electriques et Electroniques (DEEE). Il est marqué par le symbole suivant: Thermo Fisher Scientific s'est associé avec une ou plusieurs compagnies de recyclage dans chaque état membre de l’union européenne et ce produit devrait être collecté ou recyclé par celles-ci. Davantage d'informations sur la conformité de Thermo Fisher Scientific à ces directives, les recycleurs dans votre pays et les informations sur les produits Thermo Fisher Scientific qui peuvent aider la détection des substances sujettes à la directive RoHS sont disponibles s'il vous plaît contacter Thermique pour les plus amples informations. Thermo SCIENTIFIC EMC Directive 89/336/EEC EMC compliance has been evaluated by TUV SUD America Inc. EN55011 Radiated & Conducted Emissions, Industrial, scientific, and medical (ISM) products and applications, Class B, Group 1 FCC Part 15 Class B Radiated and Conducted emissions, incluidng ICES-003, AS/NZA, and CISPR22, and EN55022. EN61000-3-2 & 3-3 Harmonics and Flicker EN61326-1 Including EN61000-4-2 - ESD EN61000-4-3 - Radiated Immunity EN61000-4-4 - EFT/Burst EN61000-4-5 - Surge EN61000-4-6 - Conducted Susceptibility EN61000-4-8 - Magnetics EN61000-4-11 - Dips/Dropouts IEC 60068-2-1 Cold Test IEC 60068-2-2 Dry Heat Test IEC 60068-2-3 Humidity Static EN61010-1 (sub) Safety Requirements Low Voltage Safety Compliance This device complies with Low Voltage Directive 73/23/EEC and harmonized standard EN 61010-1:2001. Thermo SCIENTIFIC FCC Compliance Statement THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. CAUTION Read and understand the various precautionary notes, signs, and symbols contained inside this manual pertaining to the safe use and operation of this product before using the device. Notice on Lifting and Handling of Thermo Scientific Instruments For your safety, and in compliance with international regulations, the physical handling of this Thermo Fisher Scientific instrument requires a team effort to lift and/or move the instrument. This instrument is too heavy and/or bulky for one person alone to handle safely. Notice on the Proper Use of Thermo Scientific Instruments In compliance with international regulations: Use of this instrument in a manner not specified by Thermo Fisher Scientific could impair any protection provided by the instrument. Notice on the Susceptibility to Electromagnetic Transmissions Your instrument is designed to work in a controlled electromagnetic environment. Do not use radio frequency transmitters, such as mobile phones, in close proximity to the instrument. For manufacturing location, see the label on the instrument. Contents Contents About this User Manual. .7 Intended users. 7 How to use this user’s manual. 7 Related Documentation . 8 Contacting Us . 8 Safety and Special Notices . 9 Safety symbols and markings . 10 Chapter 1 Introduction . 11 System Features. 12 Principle of Operation. 13 Advantages of using the Versette system . 15 Safety . 15 Chapter 2 System Overview. 23 General Description . 23 System Configuration . 24 Accessory Options . 25 Instrument layout . 29 Chapter 3 Installation . 39 Site requirements. 39 Requirements . 42 Precautions and limitations . 43 System installation procedure . 44 Use of a Reservoir with the Non-Contact Fill Option . 60 Using a Tip Wash Station . 62 Using a Pipette Tip Waste System. 64 Using Pipette Head Nests . 67 Using a Sealed Storage Tube Piercing Manifold . 69 Using a Barcode Reader. 72 Using a Vacuum Manifold . 76 Operational check . 77 Chapter 4 Operation . 79 Theory of operation. 80 Precautions and limitations . 80 Initial system startup . 81 Operation overview . 82 Programs . 83 Touchscreen operation . 84 Using Tube Adapters. 133 System Shutdown . 133 Thermo Scientific Versette User’s Manual Rev. 2.3 1 Contents ControlMate Software. 135 Chapter 5 Frequently Asked Questions . 139 Q&As . 139 Chapter 6 Calibration for SMC Pipetting Modules Only. 141 Calibrating the System Coordinates. 142 Required Equipment . 144 BEFORE CALIBRATION . 144 STEP 1: Install the SMC Pipetting Module and SMC Teach Tool . 148 STEP 2: Calibrate Stage XY . 155 STEP 3: Calibrate the Z-axis . 162 STEP 4: Calibrate the Serial Dilute coordinates . 168 STEP 5: Calibrate the Serial Dilute Nest Positions . 176 STEP 6: Calibrate Serial Dilute Syringe Axis (“S-Axis”) . 180 STEP 7: Eject Teach Tool and Verify Head and Tip Pickup. 184 Chapter 7 Calibration for NTC Pipetting Modules Only . 189 Calibrating the system coordinates . 190 Required Equipment . 192 BEFORE CALIBRATION . 192 STEP 1: Install the NTC Pipetting Module and NTC Teach Tool. 196 STEP 2: Calibrate Stage XY Coordinates. ..
Recommended publications
  • VACUUM RECOVERY of ASPHALT EMULSION RESIDUE (An Arizona Method)
    ARIZ 504 July 1980 (3 Pages) VACUUM RECOVERY OF ASPHALT EMULSION RESIDUE (An Arizona Method) Scope (d) No. 10 sieve conforming to AASHTO designation M 92. I. This method describes a low temperature vacuum procedure for recovery of the asphalt residue (e) Vacuum recovery apparatus as shown from asphalt emulsions. It is is not suitable for assembled in Fig. I. quantitative recovery of solvents from emulsions I) Vacuum source capable of producing an containing low boiling range distillates. absolute vacuum within the system of approximately 710 mm (28 in.) mercury. Apparatus 2) Thermometer - shall have a range of _5° to 1. The apparatus shall consist of the following: +200°C (23°F to 392°F). The overall length (a) Brass stirring rod. shall be 600 mm (24 in.) and the distance from the bottom of the bulb to the zero point (b) 8 oz. ointment can. shall be 300 mm (12 in.) (c) 100 ml. stainless steel beaker. 3) Stirrer hot plate. VACUUM RECOVERY APPARATUS 300 mm Allihn condenser H20 Out / Thermometer Vacuum Release Pinch Clamp 500 m. 1,000 ml. Filtration Flask Filtration Flask Teflon Stirring Bar H20 In 500 ml. Filtration Flask Portable Heat Gun FIGURE I ARIZ 504 July 1980 4) Teflon covered stirring bar. (g) Insert the stoppered themometer (positioned 5) 1000 ml. and two 500 ml. filtering flasks with in the stopper at an angle to prevent contact with tubulation. stirring bar) into the flask and set on hot plate at a medium high heat setting (#4). The bulb of the 6) 300 mm Allihn condensor.
    [Show full text]
  • Temperature Distribution in a Vacuum Flask
    Solved with COMSOL Multiphysics 5.0 Temperature Distribution in a Vacuum Flask Introduction The following example solves for the temperature distribution within a vacuum flask holding hot coffee. The main interest here is to illustrate how to use MATLAB® functions to define material properties and boundary condition directly within the COMSOL model. Two MATLAB functions are used to define the temperature dependent thermal conductivity of the vacuum flask shell and the insulation foam, while a third function defines the heat transfer coefficient that corresponds to a natural convective cooling for a vertical plate and surrounding air. Model Definition Assume axial symmetry for this simulation to reduce the model geometry to the 2D cross-section of the vacuum flask geometry shown in Figure 1. The vacuum flask consists of a steel shell isolated with a foam material, and a cork made of nylon. On the inside wall apply a constant temperature, assuming that the vacuum flask is filled with coffee of constant temperature. 1 | TEMPERATURE DISTRIBUTION IN A VACUUM FLASK Solved with COMSOL Multiphysics 5.0 Nylon cork Air Steel shell Constant temperature Insulation foam Figure 1: Cross section of the vacuum flask geometry Define the temperature dependent thermal conductivity of steel according to the following polynomial expression: –4 2 –8 3 ksteel = 71.12– 0.115T + 1.16e T – 4.25e T As shown in Figure 2, in the temperature interval of interest for the model, the thermal conductivity decreases with increasing temperature. 2 | TEMPERATURE DISTRIBUTION IN A VACUUM FLASK Solved with COMSOL Multiphysics 5.0 Figure 2: Thermal conductivity of the steel wall versus temperature.
    [Show full text]
  • CO2 and Mass Chemistry
    CSI: Climate Status Investigations-High School CO2 and Mass Chemistry Background: Many students believe that gases like carbon dioxide (CO2) do not have mass. The fact is that atmospheric gases like CO2 and methane (CH4) have a tremendous amount of mass if you consider how much there is of them in our atmosphere. Goal: Students will determine if CO2 and CH4 have mass. Objectives: Students will … Identify that CO2 and CH4 have mass Use chemistry to determine the mass of CO2 and CH4 Learn about the density of CH4(g) Materials (per lab group): 1 - 125ml flask 1 large 12 inch balloon 1 pin (or scissors) 1 microspoon spatula 30g of baking soda 60ml of vinegar 50ml beaker Triple beam balance or similar scale Metal pie tin Safety glasses for each student CO2 and Mass – Data Sheet and Lab Procedure for each student CO2 and mass – CH4 Lab Procedure and Student Sheet for each student 60ml syringe of CH4 from Trapping CO2 lab Large bulb polyethylene transfer pipette Scissors Candle in holder Matches or lighter 3% dish soap solution Safety glasses for each student 2cm length latex tubing Time Required: Two, 45-60 minute periods Standards Met: S1, S2, S3, S6, S7 Procedure: PREP Gather all of the necessary lab materials and run a test lab to be certain of safety procedures. Give each group one lab set-up. Explain that they will be creating CO2 and CH4 in class and using these gases to examine mass and density. 1 The Keystone Center CSI: Climate Status Investigations-High School DAY ONE Review safety procedures with the students.
    [Show full text]
  • Liquefaction, Storage and Transfer of Cryofluids
    Storage and transfer of cryofluids Christian Gianese www.neel.cnrs.fr Guilty 1: Arsène d’Arsonval (1851 - 1940) He invented a glass container with double wall, the vacuum being done in the space between the outer and inner walls: the vase d'Arsonval. About 1902, he collaborated with Georges Claude on the liquefaction of gases and inspires industries Air Liquid. www.neel.cnrs.fr Guilty 2: James Dewar (1842 - 1923) He discovered a process to produce liquid oxygen in 1891 and liquid hydrogen in 1898, in industrial quantities. He developed an insulating bottle, the Dewar flask, still named after him, to study low temperature gas phenomena. In fact, he improves the d’Arsonval vessel by depositing a layer of silver on the inside wall, to minimize the heat input by radiation. He also used this bottle to transport liquid gases such as hydrogen. In 1905, he observed that cold charcoal could produce a vacuum. www.neel.cnrs.fr Thermos The first vacuum flasks for commercial use were made in 1904 when a german company, Thermos GmbH, was formed. Thermos, their tradename for their flasks, remains a registered trademark in some countries but was declared a genericized in the US in 1963 as it is colloquially synonymous with vacuum flasks in general; in fact it is far more common to speak of a domestic thermos than a vacuum flask. www.neel.cnrs.fr STORAGE www.neel.cnrs.fr The most important factors in storage systems Logistics Volume of storage, dimensions, transport, etc Reliability, safety Economics ! Rate of evaporation of cryogenic liquids (helium:
    [Show full text]
  • Carolina Biological Supply Staining Rack and Tray, a General Utility Stainless Steel Tray and Rack Well Is 8" L X 6" W and 1 1/2" S
    Bid # 18‐26 Science Supplies and Equipment Form of Proposal Item No. Item Description QTY Unit Vendor Names for Reference Purposes Only Carolina Biological Supply Staining rack and tray, a general utility stainless steel tray and rack well is 8" L x 6" W and 1 1/2" S. Overall size is 9" L x 7" W x 1 1/2" D. 4ea 1 # 742001 Electrophoresis chamber Tray makes a gel 3 1/4" W x 3 3/4" L. Safety interlock lid prevents operation unless lid is securely in place. Features 6ea 1/4" durable acrylic construction. Includes heavy, nonwarping gel‐ casting tray, makred to assist in easy sample loading and two 8‐tooth 2 combs for running 8 or 16 samples, # 213668 Microscope slide with 3 separate smears showing the characteristic 24 ea size and form of the following types of bacteria: baciluss, coccus and 3 spirillum Gram stain, # 293964 A whole mount of E. coli bacteria on a prepared microscope slide, # 24 ea 4 294546 24 ea 5 Streptococcus, wm gram stain slide, # 294738 1ea 6 Practice Pipetting stations Kit, # 211145 NOTE: THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT AN OFFICIAL BID DOCUMENT. 24 ea 7 Floating Microtube Racks, # 215578 Pyrex Glass Graduated Cylinder, Single Metric Scale, 1000 ml, # 4ea 8 721794 Page 1 of 14 Bid # 18‐26 Science Supplies and Equipment Form of Proposal Item No. Item Description QTY Unit Total Cost Vendor Names for Reference Purposes Only 10 ea 9 Sunflower Older Stem l.s. 12µm Microscope slide, # 303104 10 ea 10 Oscillatoria Slide, w.m.
    [Show full text]
  • Organic Chemistry Ii
    University of Maribor Faculty of Chemistry and Chemical Engineering Laboratory for Organic and Polymer Chemistry and Technology Laboratory Course ORGANIC CHEMISTRY II Muzafera Paljevac and Peter Krajnc Proofreader: Dr. Victor Kennedy 1. THE LIST OF LABORATORY EXPERIMENTS IN ORGANIC CHEMISTRY II LAB COURSE 1. Determination of melting point 2. Continuous (fractional) distillation 3. Distillation with water steam 4. Recrystallization, Sublimation 5. Paper and thin layer chromatography _____________________________________________________________________________________ 6. Synthesis of acetylsalicylic acid 7. Synthesis of tert-butyl chloride 8. Synthesis of methyl orange 9. Synthesis of aniline 10. Synthesis of ethyl acetate 11. Synthesis of ethyl iodide 1 2. LABORATORY RULES AND REGULATIONS - You must wear a lab coat at all times when working in the laboratory. You are expected to provide your own lab coat, and you will not be allowed to work in the lab without one. - Safety glasses and gloves will be supplied when required and must be worn where notices, experimental instructions or supervisors say so. - Long hair must be tied back when using open flames. - Eating and drinking are strictly prohibited in the laboratory. - Coats, backpacks, etc., should not be left on the lab benches and stools. There are coat racks just outside the lab. Be aware that lab chemicals can destroy personal possessions. - Always wash your hands before leaving the lab. - Notify the instructor immediately in case of an accident. - Before leaving the laboratory, ensure that gas lines and water faucets are shut off. - Consider all chemicals to be hazardous, and minimize your exposure to them. Never taste chemicals; do not inhale the vapors of volatile chemicals or the dust of finely divided solids, and prevent contact between chemicals and your skin, eyes and clothing.
    [Show full text]
  • Simple Calorimeter for Heats of Fusion. Data on The
    U.S. Department of Commerce, Bureau of Standards RESEARCH PAPER RP607 Part of Bureau of Standards Journal of Research, Vol. 11, October 1933 A SIMPLE CALORIMETER FOR HEATS OF FUSION. DATA ON THE FUSION OF PSEUDOCUMENE, MESITYLENE (« AND 0), HEMIMELLITENE, o- AND m-XYLENE, AND ON TWO TRANSITIONS OF HEMIMELLITENE By Frederick D. Rossini abstract A vacuum flask with a thermoelement serves as a simple calorimeter for measuring heats of fusion quickly and economically, with an accuracy of a few percent. The following heats of fusion (with estimated uncertainties), in k-cal. per mole, were obtained: pseudocumene, — 44.1° C, 2.75±0.06; hemimelli- tene,-25.5° C, 2.00±0.05; mesitylene (a), — 44.8° C, 2.28±0.06; mesitylene (0), -51.7° C., 1.91±0.05; o-xylene,-25.3° C, 3.33±0.07; m-xylene,-47.9° C, 2.76 ±0.05. Hemimellitene was found to have two transitions below the freez- ing point, with the following heats of transition, in A>cal. per mole: hemimelli- tene (7-»0),-58±2° C.,0.28±0.04; hemimellitene (P^a),- 46 ± 1° C.,0.36±0.04. CONTENTS Page I. Introduction 553 II. Apparatus and method 553 III. Materials 554 IV. Standardization experiments 555 V. Experimental data 557 VI. Conclusion 559 I. INTRODUCTION The simple calorimeter described here was assembled in order to provide a means for measuring as quickly and economically as prac- ticable, and with an accuracy of a few percent, the heats of fusion of certain hydrocarbons for which there are no data.
    [Show full text]
  • APR PET S-12 Dissolution Screening
    PET Dissolution Test Document Code – PET-S-12 Publication or Revision Date: November 16, 2018 Introduction – Scope, Significance and Use This protocol is derived from a copyrighted method owned by M&G Polymers USA LLC and international copyright treaties protect the method. In consideration for the use of this method, users agree to hold APR and M&G Polymers USA LLC and its affiliated companies harmless and not be liable for any incidental, consequential or other indirect damages resulting from the use of this method. Disclaimer: This document has been prepared by the Association of Plastic Recyclers as a service to the plastic industry to promote the most efficient use of the nation’s plastic recycling infrastructure and to enhance the quality and quantity of recycled postconsumer plastic. The information in this document is offered without warranty of any kind, either expressed or implied, including WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, which are expressly disclaimed. APR and its members accept no responsibility for any harm or damages arising from the use of or reliance upon this information by any party. Participation in the Recognition Program is purely voluntary and does not guarantee compliance with any U.S. law or regulation or that a package or plastic article incorporating the innovation is recyclable or will be recycled. Equipment/Supplies List • Heat resistant gloves • Apron; full length that covers torso, arms and legs • Faceshield (hood sash if available) • Metal beaker with handle, at least 700 ml capacity • Fiberglass matting for setting hot beaker on while heating and cooling • Thermometer with metal armor casing • Safety glasses • Vented Hood • Hot Plate • 1000 ml filtering flask • Buchner funnel • Filter Paper (Whatman #1, 11 micron, VWR Catalog #28450-128) ©2018 Association of Plastic Recyclers.
    [Show full text]
  • BRAND - Your Partner in the Lab
    BRAND - Your Partner in the Lab. Worldwide. General Catalog 900 ® Trademark Index accu-jet®, BIO-CERT®, BLAUBRAND®, BRAND®, BRANDplates ®, cell-culture™, cellGrade™, Dispensette®, EASYCAL™, HandyStep®, hydroGrade™, immunoGrade™, inertGrade™, lipoGrade™, nano-cap™, PLASTIBRAND®, pureGrade™, QuikSip™, SafetyPrime™, seripettor®, Titrette®, Transferpette®, as well as the logo design marks depicted here, are trademarks of BRAND GMBH + CO KG, Germany. The following brands and trademarks as referenced in the current catalog are property of their respective third-party owners as listed below: Referenced brand/trademark Owner AMERSHAM® GE HEALTHCARE LIMITED, GB APPLIED BIOSYSTEMS® Applied Biosystems LLC, USA AR-GLAS® SCHOTT AKTIENGESELLSCHAFT, Germany AutoRep™ Rainin Instrument, LLC, USA BECKMAN® Beckman Coulter, Inc., USA BIOHIT® Sartorius Biohit Liquid Handling Oy, Finland BIOMETRA® Biometra Biomedizinische Analytik GmbH, Germany BIORAD® BIO-RAD LABORATORIES GMBH, Germany Combitips® Eppendorf AG, Germany COULTER COUNTER® BECKMAN COULTER INC., USA EDISONITE® Schülke & Mayr GbmH, Germany Encode™ Rainin Instrument, LLC, USA Eppendorf® Eppendorf AG, Germany FINNPIPETTE® Thermo Fisher Scientific Oy, Finland GILSON® Gilson, Inc., USA LightCycler® Roche Diagnostics GmbH, Germany MegaBace® GE Healthcare Bio-Sciences AB, GB METTLER TOLEDO® Mettler-Toledo AG, Switzerland MICROSOFT® MICROSOFT CORPORATION, USA MJ RESEARCH® BIO-RAD LABORATORIES, INC., USA Mucasol® Schülke & Mayr GbmH, Germany Mucocit® Schülke & Mayr GbmH, Germany Multipette® Eppendorf AG,
    [Show full text]
  • Mycoplasma Screening of Cultured Cells by Fluorescence Microscopy
    Mycoplasma Screening of Cultured Cells by Fluorescence Microscopy Prepare cell samples Make sure cells have been passages at least 2 times after a thaw so mycoplasma have recovery time from their time in cold storage!! 1. With sterile tweezers or Pasteur pipet attached to vacuum flask place one 22x22mm or 25mm round sterile glass coverslip into well of sterile 6well plate (# wells = # cell lines tested) or 35mm dish. 2. Add 3 ml of (cell line specific) complete medium without antibiotics (important because they may inhibit mycoplasma and produce a false negative) slowly to the well (touch first drop of medium to the edge of the coverslip until capillary action carries the liquid under the coverslip and completely covers the underside, which holds the coverslip to the dish and disallows cell growth on the underside). 3. Add 2-4 drops of cell suspension (approximately 10^5cells) to the medium in the well. Rock gently. (Note: For testing non-adherent cells, a negative indicator line must be used. The line to be tested must be coplated with the indicator line. Mycoplasma will transfer to the indicator line within 2 days and will be visualized.) 4. Incubate 2-3 days at appropriate temperature for cell line until they are approximately 70% confluent (mycoplasma live on the outer membrane, and thus are easier to visualize when cells are subconfluent). To Fix 1. Add 3 ml methanol gently to the side of the dish (do not remove growth medium). 2. Leave for 3 min at room temperature. 3. Aspirate methanol/medium solution. 4. Add 3 ml methanol for 15 min at room temperature.
    [Show full text]
  • Inquiry-Based Laboratory Work in Chemistry
    INQUIRY-BASED LABORATORY WORK IN CHEMISTRY TEACHER’S GUIDE Derek Cheung Department of Curriculum and Instruction The Chinese University of Hong Kong Inquiry-based Laboratory Work in Chemistry: Teacher’s Guide / Derek Cheung Copyright © 2006 by Quality Education Fund, Hong Kong All rights reserved. Published by the Department of Curriculum and Instruction, The Chinese University of Hong Kong. No part of this book may be reproduced in any manner whatsoever without written permission, except in the case of use as instructional material in a school by a teacher. Note: The material in this teacher’s guide is for information only. No matter which inquiry-based lab activity teachers choose to try out, they should always conduct risks assessment in advance and highlight safety awareness before the lab begins. While every effort has been made in the preparation of this teacher’s guide to assure its accuracy, the Chinese University of Hong Kong and Quality Education Fund assume no liability resulting from errors or omissions in this teacher’s guide. In no event will the Chinese University of Hong Kong or Quality Education Fund be liable to users for any incidental, consequential or indirect damages resulting from the use of the information contained in the teacher’s guide. ISBN 962-85523-0-9 Printed and bound by Potential Technology and Internet Ltd. Contents Preface iv Teachers’ Concerns about Inquiry-based Laboratory Work 1 Secondary 4 – 5 Guided Inquiries 1. How much sodium bicarbonate is in one effervescent tablet? 4 2. What is the rate of a lightstick reaction? 18 3. Does toothpaste protect teeth? 29 4.
    [Show full text]
  • Pipettes Resource Guide 2018 Pipettes Resource Guide
    PIPETTES RESOURCE GUIDE 2018 PIPETTES RESOURCE GUIDE INTRODUCTION LESSON IN LIQUID HANDLING by Trevor Henderson, PhD by Erica Tennenhouse, PhD QUESTIONS TO ASK WHEN FOCUS ON PIPETTE TIP DESIGN BUYING A PIPETTE by Angelo DePalma, PhD by Lab Manager INSIGHTS INTO... PURCHASING TIPS • Personalized Pipettes by Angelo DePalma, PhD • Low-Volume Pipetting by Mike May, PhD and Angelo MAINTENANCE MATTERS DePalma, PhD by Rachel Muenz Lab Manager 2017 1 LabManager.com Introduction by Trevor Henderson, PhD Pipetting is part of nearly every laboratory’s workflow. The goal of pipetting is to ensure maximum accuracy and repeatability when transferring fluids. Research and development labs in the chemicals, foods, materials, and paints industries use pipettes routinely. However, it is in the life sciences that the greatest number of pipettes and related supplies are found. This established technology continues to undergo improvements, most related to usability and consistency. If you’re looking to buy one, there are many different features to take into consideration before making your purchase, including ergonomics, low force, fitting, ease of use, reliability, accuracy, and precision. Lab Manager 2017 2 LabManager.com PIPETTES RESOURCE GUIDE Questions to Ask When Buying a Bath or Chiller by Lab Manager How does my sample volume influence which pipette is the best fit? Pipettes come in a variety of different sizes to suit whichever volume needs are required. If you know you will always be pipetting the same volume of liquid, then a fixed volume pipette will be best. If the amount to be pipetted is changing from sample to sample, then a variable pipette will be ideal.
    [Show full text]