Worcester Controls Product Catalog

Experience In Motion To Access Literature On-line More information about products can be obtained on-line. It’s easy to find… it’s free… and you do Table of Contents not need a password. Do This: Section Page Product Index...... 3  Go to www.flowserve.com/library 3-piece...... 4  Search the library Flanged...... 5 Wafer...... 6 Directional...... 6 Enter criteria or Enter keyword or literature number Special Service Fugitive Emissions...... 6 Chlorine...... 7 Firesafe...... 7 Cryogenic...... 7 High Purity...... 8 Tank Bottom...... 8 High ...... 9 Control...... 9 Actuation Actuator Electric...... 10 Pneumatic...... 11 Switch Box The most recent version of each product bulletin will be End Mount...... 12 available on this site. Top Mount...... 12-13 Once you have the PDF, you can: Positioner • read it Pneumatic...... 14 • print it Electric...... 15 • download it • even e-mail it flowserve.com

Flowserve rotary offer easy maintenance and automation backed by market-friendly expertise and quality heritage brands

Product Index

Product Page Product Page Series Series 34 11 DFC17 15 36 10 DFP17 15 44 4 DS/DM 6 45 4 ELK39 12 59 4 F39 11 F519/529 5 75 10 F819/829 5 94 6 F72 10 151 6 FZ44 7 301 6 FZ51/52 7 51/52 5 FZ94 7 ACCESS 11 H44 9 AF17 15 H71 9 AF44 7 L93 Pulsair 14 AF51/52 7 PT 9 AF94 7 TB59 8 Aviator/BUSwitch 13 W7000 14 14 C4 7 W8000 C44 7 WWS/WWM 12 C51 7 WK70 8 CL44 7 WK74 8 CL51/52 7 WPS/WPM 12 CL94 7 WXCL 13 CPT 10

3 Series 44 Series 59 Series 45/59 3-Piece Regular Port 3-Piece Full Port 3-Piece Larger Sizes Three-Piece

Features Features Features • 3 Piece Regular Port design Ball Valve • 3 Piece Full Port design Ball Valve • Large-diamater, 3 Piece design Ball Valve • ASME class 600 design • ASME class 600 design • ASME Class 300 design • Meets ASME B16.34 requirements • Meets ASME B16.34 requirements • Three piece design allows valve to act as a valve (consult Pressure/Temperature Charts) (consult Pressure/Temperature Charts) and union • “Live loaded” stem seal design • “Live loaded” stem seal • Large diameter bore for O.E.M. equipment and • Multiple soft and metal seat options • Multiple soft and metal seat options packaging systems • Tight Shut off and Bi-Directional sealing • Tight Shut off and Bi-Directional Sealing • Compact design with multiple options • Cavity Filled Designs • Cavity Filled Designs • Tight Shut off and Bi-Directional sealing • Special Service Applications: • Full Port design minimizes pressure drop • Cavity Filled Designs UL, FM, USCG and other Special service across the valve and maintains a high approvals efficiency,reducing pumping cost. Sizes • Locking Device as standard • Locking Device as standard • 45 Series 2½" to 6" 59 Series 2½ to 4" Sizes Sizes • Screwed end • ¼˝ to 2˝ • ¼˝ to 2˝ • Socket weld • Screwed end • Screwed end • Butt weld • Socket weld • Socket weld • Butt weld, Solder ends ( only) • Butt weld, Solder ends (Brass only) Materials • Carbon Steel Materials Materials • Stainless Steel • Carbon Steel • Carbon Steel Standards • Stainless Steel • Stainless Steel • ASME B16.34 • Brass • Brass • S.E. to ASME B 2.1 • Monel • Monel • S.W. to ASME B 16.11 • Alloy 20 • Alloy 20 • Hastelloy-C • Hastelloy C

Standards Standards • ASME B16.34 • ASME B16.34 • S.E. to ASME B 2.1 • S.E. to ASME B 2.1 • S.W. to ASME B 16.11 • S.W. to ASME B 16.11

Get more information: Get more information: Get more information: Product brochure: Product brochure: Product brochure: • WCABR1050 • WCABR1050 • WCABR1050

IOM: IOM: IOM: • WCENIM2030 • WCENIM2030 (for Miser) • WCENIM2046 • WCENIM2054 (for FM) See page 2. See page 2. See page 2.

4 Series 51/52 Series F519/F529 Series F819/F829 Flanged Regular Port Flanged Full Port Flanged Full Port Flanged

Features Features Features • Flanged Regular Port Unibody Design • Flanged Full Port Unibody Design • Flanged Full Port Split Body Design • ASME class 150/300 • ASME class 150/300 • ASME class 150/300 • Tight shut-off • ISO 5211 mounting • ISO 5211 mounting • “Live loaded” stem seal • “Live loaded” stem seal • Full Port design minimizes pressure drop • Multiple soft and metal seat options • Multiple soft and metal seat options across the valve and maintains a high • Wide variety of Body, Seat and Seal materi • Full Port design minimizes pressure drop efficiency,reducing pumping cost. als means dependable, high cycle control on across the valve and maintains a high • Wide variety of Body, Seat and Seal materi- Steam, Petroleum products, Chemicals and efficiency,reducing pumping cost. als means dependable, high cycle control on abrasive liquids • Wide variety of Body, Seat and Seal materi- Steam, Petroleum products, Chemicals and • Pre-drilled mounting holes for actuation als means dependable, high cycle control on abrasive liquids • Tight Shut off and Bi-Directional sealing Steam, Petroleum products, Chemicals and abrasive liquids • Firesafe by design Sizes Sizes • 2˝ to 8˝ • 1/2˝ to 10“ Flanged Sizes • ASME 150# and 300# class • ASME 150# and 300# class • ½˝ to 1½˝ • ASME 150# and 300# class Materials Materials Carbon Steel • Carbon Steel Materials Stainless Steel • Stainless Steel • Carbon Steel • Stainless Steel Standards Standards • API 6D • ASME B16.34 Standards • API 607 4th Edition • ASME B16.34 • ASME B16.34 • API 607 Fire Test • NACE MRO1-75

Get more information: Get more information: Get more information: Product brochure: Product brochure: Product brochure: • WCABR1013 • WCENBR0032 • WCENBR0032

IOM: IOM: IOM: • WCENIM2014 (for smallvalves) • WCEIM0519 • WCENIM0013 (for std. valve) • WCENIM2015 (for large valves) • WCENIM2057 (for fugitive emission) • WCENIM2052 (for FM) See page 2.

See page 2. See page 2.

5 www.flowserve.com fugitive Emissions. WCABR1023 WCENIM2003 (for Series 94) WCENIM2057 (for Series E818/828) API 607 Fire Test S.W. to ASME B 16.11 S.E. to ASME B 2.1 ASME B16.34 Hastelloy-C trim option Stainless Steel Carbon Steel ½˝ to 8˝ Flanged design Butt weld Socket weld Screwed end ½˝ to 2˝ 3 piece design Pressure classes to ASME 600 Suitable for Category M services High cycle capability High Vacuum capability Double „live loaded“ Stem seal design allowed applications, where no stem leakage is Outstanding performance on high-cycle Specially designed to control and minimize Specially designed to control IOM: • • See page 2. Get more information: Product brochure: • Series 94, 94-150, 94-300, 94-300, 94-150, 94, Series 94-600 Emission Fugitive

• • • Standards • • • Materials • • • • • Sizes • • • • • •

• Features • WCABR1052 WCENIM2030 (for Miser) WCENIM0009 (for 18/19) Multi-port Diverter Valves Three-piece or flanged design Bottom entry or side entry Full port or regular port 90 or 180 degree operation The D51 cast flanged have similar operations as the D44/D4 but for larger sizes The D44/D4 3-piece diverter valve is designed to accept media through a bottom inlet port and direct it to either of two outlet ports ASME 150 flanges The 18/19 Series is extremely adaptive . Up to 5 ports . multiple seat and body materials . regular or full port . Optional fugitive emission design . Class 150 or 300 . Screwed, socket or butt weld and slip-on flanges WCENIM2015 (for large valves)

Get more information: Product brochure: • IOM: • • See page 2. Features • • • • • • • • • Sizes ½˝ to 2˝ for D44/D4 3-piece valve 2˝ to 8˝ for D51 Flanged valve 1˝ to 6˝ for Series 18 & 19 valve Materials Carbon Steel Stainless Steel Standards ASME B16.34 API 607 Fire Test • Series D44/D4, D51, 18/19 D51, D44/D4, Series Directional

WCABR1041 WCENIM2015 Wafer Design Designed for light weight. Symmetrically balanced to avoid side loads from actuation 40-60% less weight than conventional ball valves Suitable for Steam processes including veg- etable peelers, Steam ejectors, Distilleries, and more. 3˝ to 6˝ ASME 150# and 300# class Rated at 720 CWP Carbon Steel Stainless Steel Ductile iron • IOM: • Get more information: Product brochure: See page 2.

• • • Sizes • • • Materials • Bronze • • • Features • Series 151 and 301 and 151 Series Pattern Wafer

Wafer, Directional and Fugitive Emissions 6 Series CL94, CL44, CL 51/52 Series AF44, FZ44, AF51/52, FZ51/52, Series C4, C44, and C51 FM51/52, AF94, FZ94,F519/529, F819/829 Cholrine Cryogenic Firesafe

Features Features Features • Special for Chlorine Service • Fire-Safe Valves • Cryogenic Services

• Liquid and gas • Ensure operational integrity before, during, • High-performance, shutoff valves for inter- Chlorine, Firesafe, Cryogenic • Relief vent in ball vents to the high pressure and after a fire. mittent and continuous flow applications side • Tight Shut off, Anti static, no external leak- with temperatures to -425°F • Constructed in accordance with the recom- age • Positive Ball/Cavity relief with V3 vent hole mendations of the Chlorine Institute includ- • Available with 94 FEM stem design • Zero Leak packing ing special testing, cleaning and packaging • Pressure classes to ASME 600 • Effective Bonnet Extensions • Available with 94 FEM stem design • Valves designed for low thermal stress, auto- • Assembled in Class 1000 clean room Sizes mation and Fire Safety • Pressure classes to ASME 600 • ½˝ to 2˝ 3 piece design • Assembled in Class 1000 clean room • Screwed end • Pressure classes to ASME 600 Sizes • Socket weld • ½˝ to 2˝ 3 piece design • Butt weld Sizes • Screwed end • ½˝ to 10˝ Flanged design • ½˝ to 2˝ 3 piece design • Socket weld • Screwed end • Butt weld Standards • Socket weld • ½˝ to 4˝ Flanged design • ASME B16.34 • Butt weld • API 607 Fire Test • ½˝ to 6˝ Flanged design Materials • EXES 3-14-1-2A Carbon Steel/Monel Trim • FM 7440 Materials • Brass Standards • Stainless Steel • ASME B16.34 • Chlorine Institute Pamphlet 6 Standards • MSS-SP-72, B31.1, B31.3 • ASME B16.34 • API 607 Fire Test

Get more information: Get more information: Get more information: Product brochure: Product brochure: Product brochure: • WWCABR1039 • WCABR1029 • WCABR1040

IOM: IOM: IOM: • WCENIM2003 (for series 94) • WCENIM2003 (for series 94) • WCENIM2006 (for R12/R6 or earlier) • WCENIM2014 (for small 51/52) • WCENIM2014 (for small 51/52) • WCENIM2038 (for std. valve) • WCENIM2015 (for large 51/52) • WCENIM2015 (for large 51/52 & 151/301) • WCENIM2030 (for Miser) • WCENIM2020 (for series 818/828) See page 2. • WCENIM2030 (for Miser) See page 2. • WCENIM2047 (for series 82/83) • WCENIM2052 (for 51/52 FM) • WCENIM2054 (for O&G shutoff FM) • WCENIM2057 (for fugitive emissions)

See page 2.

7 www.flowserve.com

WCENBR1028 WCENIM2001 Socket weld, Butt weld Screwed end 1˝ to 4˝ 3 piece design Pressure classes to ASME 300 services Available prepared for O2 and vacuum tank bottom end piece design. Worcester 3 pc design advantages with a and Cosmetic Processing For Biotech, Pharmaceutical, Food, Chemical Flush, Tank-bottom Drain valve Flush, Tank-bottom Drain Get more information: Product brochure: • IOM: • See page 2. • • Sizes • •

• Features • Series TB59 Series Bottom Tank

WCABR1037 WCAIM2018 High Purity, Cast 316L - Tube bore High Purity, Cast 316L Class 100 Clean Room Assembly 20Ra interior surface finish Controlled ferrite <5% Controlled sulfer for orbital welding CMTRs standard 3" to 4" 3 piece design Extended butt weld Hygienic Clamp ASTM A351-CF3M, ASTM A479 Interior Surface Finish: 20Ra standard, 15Ra electropolished Seats/Seals: PTFE, Polyfill ASME BPE USP VI High purity and aseptic processes, sterile steam, high purity water, fermentation, lyophilization, food processing Get more information: Product brochure: • IOM: • See page 2. • • • • • • Sizes • • • Materials: • • • Standards • • FDA(21CFR) • • USDA Applications • Features Series WK74 Series Purity High

WCABR1036 WCAIM2018 High Purity, Forged F316L - Tube bore High Purity, Forged F316L Class 100 Clean Room Assembly 20Ra interior surface finish Controlled ferrite <1% Controlled sulfur for orbital welding ½" to 2" 3 piece design Extended butt weld Hygienic Clamp ASTM A182 F316L, ASTM A479 Interior Surface Finish: 20Ra standard, 15Ra electropolished Seats/Seals: PTFE, Polyfill ASME BPE USP VI Pharmaceutical/Biotech, microelectronics, steam distribution and distillation, fermentation, lyophilization, food and beverage Series WK70 Series Purity High Get more information: Product brochure: • IOM: • See page 2. Features

• • • • • CMTRs Sizes • • • Materials: • • • Standards • • FDA(21CFR) • • USDA Applications • •

High Purity, Tank Bottom 8 High-per Mizer Series 4,H44andPT See page2. • • • Standards • • • • • Sizes • • • • • Features • • IOM: • Product brochure: Get moreinformation: (Consult productcatalog) S.W. toASMEB16.11 S.E. toASMEB2.1 ASME B16.34 3" to6"Waferdesign ½˝ to6˝Flangeddesign Socket weld,Buttweld Screwed end ½˝ to2˝3piecedesign fluids andCNG Used inSteam,Hydraulics,gassesand aboveASME600to5000psi High Temperatureapplications Resilient seatedvalvesforHighpressureand High-Pressure Valves WCENIM2030 (forMiser) WCENIM2015 (forlarge51/51) WCABR1051

Hydromizer Series H71 • Features • • • Standards • • • Sizes • tions) • • • •

See page2. • Product brochure: Get moreinformation: • IOM: High-Pressure Valves (Consult productcatalog) S.W. toASMEB16.11 S.E. toASMEB2.1 ASME B16.34 Socket weld,Buttweld Screwed end ½˝ to2˝3piecedesign fluids, CNGandSubsea Used inSteam,Hydraulics,gassesand (Consult BrochureforPTcurvesandlimita- ASME Class2500(½"&¾") ASME Class1500(1"to2") High Temperatureapplications Resilient seatedvalvesforHighpressureand WCENIM2024 WCABR1051

See page2. • • • Standards • • • • • • Sizes • • • • • • • Features Series CPT • • IOM: • Product brochure: Get moreinformation: (Consult productcatalog) S.W. toASMEB16.11 S.E. toASMEB2.1 ASME B16.34 (Consult Literature) Pressure classestoASME600 3" to6"Waferdesign ½˝ to4˝Flangeddesign Socket andButtweld Screwed end ½˝ to2˝3-piecedesign Efficient ShearingAction High Rangeability Custom-cut CharacterizedSeats High CycleCapacity Zero externalleakage Precision Control,highcapacity with arevolutionarydesign The CPTisacharacterizedseatControlValve WCENIM2040 (forseries44,51,52) WCENIM2009 (forseries94) WCABR1001

www.flowserve.com

9 High Pressure, Control Valves

WCENBR1022 WCAIM2049 Oil Field Steam Generators Burner Management Water/Waste Water Tank Farms Oil & Gas Safety Shut Off Long operational life FM 7411 Fast moving valve closure Class 1, Div 1, Groups B, C, D Fail-safe on power failure No hydraulic reservoir- mounts in any position NEMA 4, 4X 120, 240 VAC, 24 VDC 0 F to 150 F Up to 900 in-lbs ( end of spring ) FM Approved Two Year Warranty Simple 2-wire control No clutches, battery packs or clock springs IOM: • See page 2. Get more information: Product brochure: • Features • Dampers • • • • • Applications • • • • Hazardous Area Classification • • Enclosure • Supply Voltage • Temperature Range • • Cost-effective Torque Range • • • • • F72 Series Actuator Electro-Hydraulic

WCABR1014 WCAIM2013 Process control for rotary valves, dampers and multi-turn chokes Boiler feed water Temperature control (steam, thermal fluid) Chemical, Power, Water/Waste Water, Food & Beverage, HVAC Two year warranty Baked epoxy coated Permanently lubricate gear train Manual override Thermal overload protection Reversable rotary operation Extended duty cycle motors Fail safe capability Positioners and P.I.D. controllers Hard anodised coating 150 - 3000 in-lbs 120, 240 VAC, 12, 24 VDC NEMA 4, 4X Class 1, Div 1, Groups C, D Get more information: Product brochure: • IOM: • See page 2. Features Applications • • • • • • • • • • Optional Features • • • • Torque Range • Temperature Range • -40 F to 150 F Supply Voltage • Enclosure • Hazardous Area Classification • 75 Series Actuator Electric

WCABR1006 (36 Series) WCABR1007 (36T Series) WCAIM2007 Compact size Permanently lubricated and sealed gear train Thermal overload protection Simple mounting and installation Additional output switch Solid-State timer option for automatic 150 in-lb and 550 in-lb output torques 0 F to 150 F 120, 240 VAC NEMA 1, 4 and 4X Industrial quarter-turn ball valves Air Drying Equipment Sampling systems Compressor installations Condensate draining Tank draining Get more information: Product brochure: • • IOM: • See page 2.

• • • • • cycling Torque Range • Temperature Range • Supply Voltage • Enclosure • Applications • OEM installations • • • • • Features • 36 Series Actuator Electric

Electric Actuator 10 Pneumatic Actuator Series 34 Get moreinformation: • • Applications • Hazardous AreaClassification • Enclosure • Supply Voltage • Temperature Range • Torque Range • • • • • • • • Features See page2. • IOM: • Product brochure: Automative, OEM,Chemical&Water Industrial Qtr-Turnvalveautomation Class 1,DivGroupsA,B,C,D NEMA 1,4,4x 12, 24VDC,24,120,240,480VAC -25 Fto160F,Optional250 Up to1000in-lbs@100psiinput High temperatureoption Built-in solenoidairpilot Fail-safe springreturnoption Single externalairandelectricalconnections Adjustable speedcontrol Minimum airconsumption Baked epoxycoating Compact Scotch-Yokedesign WCAIM2008 WCENBR1004

Pneumatic Actuator Series F39 Features • • • Applications • Hazardous AreaClassification • Enclosure • Pressure Range • Supply Voltage • Temperature Range •Up to60,000in-lbs@120psiinput Torque Range • • • • • • • • •

• Product brochure: Get moreinformation: See page2. • IOM: High Performance,CycleDesign Power, Oil&Gas,FoodBeverage Chemical, Petrochemical&Refining, Class 1,DivGroupsA,B,C,D NEMA 1,4,4x 30-120psi DA,40-120psiSR 12, 24VDC,24,120,240VAC -40 Fto212F;(hightempoption300F) Limit stops End mountsolenoid/switchaccessories End capairsupplyports Multi-spring forcetransfer Polished stainlesssteelguiderods NAMUR, ISOmounting Extruded, anodizedaluminumbody Twin piston,doublerack&pinion Two-Year warranty WCENIM2036 WCENBR1003

• • • • • Applications ULCSAapproved • • Hazardous AreaClassification • Enclosure • Pressure Range • Supply Voltage • Temperature Range • Position Switch • Torque Range • • • • • • • Features See page2. • • IOM: • Product brochure: Get moreinformation: Pneumatic Actuator ACCESS WCAIM2023 (DeviceNet) WCAIM2028 (intrisicallysafe) Food &Beverage,Pharmaceutical Petrochemical &Refining,OilGas, Digital BusNetworks,Chemical, Intrinsically Safe,NRTL/Capproved Class 1,DivGroupsB,C,D NEMA 4,4X 40 to120psi 12, 24VDC,24,120,240VAC 0 Fto160 SPDT/DPDT, GoldContact,Proximity Up to60,000in-lbs@120psiinput Digital busnetworks Diagnostic LEDcircuitboard No mountingbrackets Manual overrideandspeedcontrol High flowspoolvalve Single electricalconnection Integral solenoid&positionswitch WCAIM2032 (AS-i) WCAIM2027 (standard) WCABR1024 www.flowserve.com 11 Pneumatic Actuator Series ELK39 Series WWS/WWM Series WPS/WPM End Mounted Switch Box Top Mounted Switch Box Top Mount Switch Box

Switches

Features Features Features • End mount versus top mount • UltraDome visual position indicators for high • UltraDome visual position indicators for • Reduced assembly height contrast, wide angle viewing high contrast, wide angle viewing • Reduced installation envelope • Compliance to NAMUR VDI/VDE 3845 • Compliance to NAMUR VDI/VDE 3845 • Eliminates mounting kits mounting specifications eliminates coupler mounting specifications eliminates coupler • Multiple switch options and maximizes interchangeability and maximizes interchangeability • Aluminum enclosure • Captive stainless steel cover screws • Captive stainless steel cover screws • CSA & FM Approvals • Prewired multipoint terminal strip • Prewired multipoint terminal strip • Quick-Set spring loaded cams are extra wide • Quick-Set spring loaded cams are extra Housing Material and splined to permit tool-free limit switch wide and splined to permit tool-free limit • Die cast aluminum, epoxy coated calibration switch calibration • Extensive switch offering for a wide range of • Extensive switch offering for a wide range Enclosure applications including mechanical, of applications including mechanical, • NEMA 4, 4X; CSA approved proximity and solid state feedback options proximity, solid state and analog feedback options Hazardous Area Classifications Description • Class1, Div1, Groups C,D Provides a compact and economical glob- Description • Class1, Div2, Groups E,F, G ally certified weatherproof, non-incendive or Engineered resin enclosure provides excellent intrinsically safe package for visual and remote protection in harsh, corrosive environments. Position Switch electrical indication of valve position. Globally-certified weatherproof, non-incendive • SPDT/DPDT, Gold Contact, Proximity or intrinsically safe package for visual and Housing Material remote electrical indication of valve position. Temperature Range Die cast aluminum; dichromate conversion • 0 to 160 F undercoat; electrostatic powder top coat Housing Material Engineered resin enclosure; 25-33% fiberglass- Engineered resin enclosure; 25 - 33% Switch Ratings filled for harsh, corrosive applications fiberglass-filled for harsh, corrosive • SPDT-15 Amp, 125, 250, 480 VAC; 1/2A, 24 VDC applications • DPDT-10Amp, 125, 250 VAC; 0.3A,125 VDC Enclosure • Proximity Sensor - (5-200mA, 20-140 VAC, • IP66, IP67, NEMA 4, 4x Enclosure 10-140 VAC, UL listed, CSA Certified) • IP66, NEMA 4, 4x Hazardous Area Classifications Applications • Intrinsically Safe ATEX II 1GD Ex ia IIC T4/ Hazardous Area Classifications • Remote position indication T5/T6 • Intrinsically Safe ATEX II 1G Ex ia IIC T4/ • Relay device for pumps • Intrinsically Safe cCSAus, Cl. I, Div. 1, Gr. T5/T6 • Alarms and indicator lights A,B,C,D, Cl. II, Div. 1, Gr. F,G, Cl. III T3 • Increased Safety ATEX II 2G Ex e mb IIC T6 • Industrial, Chemical, Petrochemical installa- • 1, Gr. A,B,C,D, Cl. II, Div. 1, Gr. F,G, Cl. III T3 • Intrinsically Safe IECEX Ex ia IIC T4/T5/T6 tions • Non-Incendive cCSAus, Cl. I, Div. 2, Gr. • Intrinsically Safe cFMus/cCSAus, Cl. I,II,III, A,B,C,D, Cl. II, Div. 2, Gr E,F,G T3" Div. 1, Gr. A,B,C,D,E,F,G T5 • Non-Incendive cFMus/cCSAus, Cl. I, Div. 2, Gr. A,B,C,D, Cl. II, Div. 2, Gr E,F,G T5

Get more information: Get more information: Get more information: Product brochure: Product brochure: Product brochure: • WCABR1027 • WCENBR0135 • WCENBR0134

IOM: IOM: IOM: • WCAIM2051 • WCENIM0135 • WCENIM2075

See page 2. See page 2. See page 2. 12 Series WXCL Series DS/DM UltraSwitch™ Aviator BUSwitch Top Mounted Switch Box Top Mounted Switch Box Top Mount Integrated Valve Controller Switches

Features Features Description • UltraDome visual position indicators for high • Tool-free Quick-Set™ cams Designed for use with pneumatic rotary contrast, wide angle viewing • Switches available in a wide range of industrial valve actuators in hazardous • Compliance to NAMUR VDI/VDE 3845 options locations. With the same features as the mounting specifications eliminates coupler • Easily accessed pre-wired terminal strip UltraSwitch, the Aviator provides actuator/ and maximizes interchangeability • Minimum two open terminals are provided valve control by receiving a direct solenoid • Captive stainless steel cover screws • Housing of aluminum or corrosion voltage signal. Also provides remote • Prewired multipoint terminal strip resistant stainless steel indication of open and closed valve posi- • Quick-Set spring loaded cams are extra wide • Optional 4-20mA feedback signal tions by completing separate electrical cir- and splined to permit tool-free limit switch cuits. The BUSwitch provides actuator/valve calibration Description control by receiving a direct solenoid voltage • Extensive switch offering for a wide range of Compact housing in aluminium or corro- signal. Also provides remote indication of applications including mechanical, sion resistant stainless steel can be directly open and closed valve positions by complet- proximity, solid state, and analog feedback and easily mounted onto actuators for both ing separate electrical circuits. Available in the options rotary and linear indication and can be used following CAN bus protocols: AS-i, DeviceNet, as a junction box for direct connection of Foundation Fieldbus and Profibus DP. Description solenoid valves. Up to three cable entries • Provides a heavy-duty and rugged globally certi- and pre-wired switches to enable easy Housing Material fied explosion-proof package for visual and installation. • Aluminum (WNXV models) remote electrical indication of valve position • Engineered Resin (WR model) Housing Material Housing Material • Aluminum Enclosure • Die cast aluminum; dichromate conversion • Stainless steel • IP65, NEMA 4, 4X, 7 and 9 undercoat; electrostatic powder top coat

Enclosure Enclosure Hazardous Area Classifications • IP66, IP67, NEMA 4, 4X, 7 and 9 IP66, NEMA 4, 4X, 7 and 9 • Flameproof ATEX II 2G Ex d IIB T3/T4 • Flameproof IECEX Ex d IIB T3/T4 IP65 Hazardous Area Classifications Hazardous Area Classifications • Explosion-Proof cCSAus Cl. I, Div. 1, Gr. C • Flameproof ATEX II 2GD Ex d IIB T5, Ex tD • Flameproof ATEX II 2G Ex d IIC T4 Gb, Ex & D, Cl. II, Div. 1, Gr. E,F,G, Div. 2 F,G, Cl. A21 IP66/IP67 tb IIIC T113 °C Db IP66 III • Flameproof IECEX Ex d IIB T5, Ex tD A21 • Flameproof IECEX Ex d IIC T4 Gb, Ex tb • Flameproof cCSAus Cl. 1, Zone 1, Gr. IIB, Ex IP66/IP67 IIIC T113 °C Db IP66 d IIB T3/T4 IP65, Aex d IIB T3/T4 IP65 • Explosion-Proof cCSAus Cl. I, Div. 1, Gr. C & • Explosion-Proof CSA Cl. I, Div. 1, Gr. • Non-Incendive cCSAus Class I, Div. 2, Gr. D, Cl. II, Div. 1, Gr. E,F,G, Cl. III, T3 B,C,D, Cl. II, Div. 1, Gr. E,F,G, Cl. III T4 A,B,C,D • Non-Incendive cCSAus Cl. I, Div. 2, Gr. • Explosion-Proof CSAus Cl. I, Div. 1, Gr. • Intrinsically Safe FM(US/CAN)/cCSAus, Cl. A,B,C,D T3 A,B,C,D, Cl. II, Div. 1, Gr. E,F,G, Cl. III T4 I,II,III, Div. 1, Gr. A,B,C,D,E,F,G T5 • Intrinsically Safe FM(US/CAN)/cCSAus, Cl. I,II,III, Div. 1, Gr. A,B,C,D,E,F,G T5 • KOSHA Ex d IIB T5 • INMETRO Ex d IIB T5 Gb, Ex tb IIIC T100 °C Db IP65

Get more information: Get more information: Get more information: Product brochure: Product brochure: Product brochure: • WCENBR1057 • WCENBR0136 • WCENBR1057

Product Specification : IOM: IOM: WCENPS1056 • WCENIM0136 • AXENIOM0100

IOM: See page 2. See page 2. • WCENIM2076

See page 2. 1313 www.flowserve.com

WCAIM2055 Position indication, fail freeze, remote mount FM - Class1, Div1, Groups B,C,DI. I.S. - Class1, Div1, Group A,B,C,D CSA - Class1, Div1, Groups BCDEFG ATEX - EExd, EEx ia, EEx nl IP66, NEMA 4x Stainless steel Die cast aluminum, epoxy paint NAMUR output, ISO mounting Digital communication options “Zero” air bleed design Piezoelectric low power control Two-stage air delivery Auto calibration High visability graphic display Simple user interface Loop powered, microprocessor design Linear and rotary actuator control Linear and rotary actuator High performance digital process control for linear and rotary actuators for modulating control Get more information: Product brochure: • AWCABR1019 IOM: • See page 2.

Applications • I.S. - Class1, Div1, Group A,B,C,D Temperature Range • -22F to 185F Accessories • •

• Hazardous Area Classification • Enclosure • • Housing Material • • • • • • • • • • Features • Series L93 Pulsair L93 Series Positioner Mount Top Class II, Divisions 1 & 2, E,F,G Groups A, B, C, D T4 Groups A, B, C, D T4 WCENIM2078 Get more information: Product brochure: • AXENBR0007 IOM: • See page 2. Description provides extremely The APEX 8000 positioner precise control for a wide range of valve and damper applications. The two-stage pneumatic relay provides faster, more sensitive response characteristics to meet the most demanding control objectives. Pneumatic and electro-pneumatic input options available that can be field retrofitted. Also available with many advanced features such as limit switch feedback, analog feedback and UltraDome visual position indicators. Housing Material Die cast aluminum with electrostatic powder coating or optional epoxy coating Enclosure NEMA 4, 4x, 7 and 9 Hazardous Area Classifications • FM Class I, Divisions 1 & 2, Groups B,C,D, • FM Intrinsically Safe Class I, Division 1, • FM Class I Zone 0 AEx ia IIC T4 • FM Non-incendive Class I, Division 2, • ATEX Intrinsically Safe II 1 G EEx ia IIC T6 • FM Class I, Division 2, IIC T4 • ATEX II 2 GD EEx d IIB + H2 T6 Series APEX W8000 APEX Series Positioner Mount Top Severe Service ®

Groups B,C,D Groups A,B,C,D AXENBR0006 Non-interactive zero and span adjustment greatly simplifies and reduces calibration. Interchangeable I/P Modules allow positioner to be field converted for 3-15 psi or 4-20 mA input signals Multiple cam options allow configuration of positioner characteristics to match valve requirements Gold-plated spool valves available in low or high flow versions to match actuator/valve load requirements Low-profile flat or optional UltraDome visual indicator provides full-area, wide angle viewing of valve position. Top-Mounted UltraSwitch optional for position feedback requirements • FM/CSA Class I, Divisions 1 and 2, • FM/CSA Class II, Groups E, F, G • ATEX II 2 G EEx d IIB + H2 • ATEX II 2 G EEx d IIC • FM Intrinsically Safe ATEX II 2 G EEx ia IIC • FM Intrinsically Safe Class I, Division 1, Get more information: Product brochure: • See page 2. NEMA 4, 4x • • • • • • Coating Hazardous Area Classifications Enclosure Features powder coating or TUFRAM Description provides accurate Compact, rugged design valve positioning at a competitive price. Available with pneumatic and electro- pneumatic input options that can be field retrofitted. Housing Material Die cast aluminum with electrostatic epoxy Series APEX W7000 APEX Series Positioner Mount Top

Positioners 14 Series AF17 Series DFP17 DataFlo Series DFC17 DataFlo Electric Actuator Positioner Electric Actuator Positioner Electric Actuator Controller Positioners

Features Features Features • Solid-state circuit board • Microprocessor control • Microprocessor PID control • Multiple signal inputs • Pushbutton calibration • Autotuning • LED calibration • Speed control • Local process control • Deadband control • Electronic travel stops • Pushbutton calibration • Direct and reverse acting • Adjustable dead band • Performance monitoring • Position feedback • Multiple I/O options • Mulitple I/O options • Digital network communications • Modbus network communications Housing Material • 20 programmable functions • RS485 network communications • Die cast aluminum, epoxy paint • Desktop software Housing Material Supply Voltage • Die cast aluminum, epoxy paint Housing Material • 12, 24 VDC, 120, 240 VAC • Die cast aluminum, epoxy paint Supply Voltage Standard Inputs • 12, 24 VDC, 120, 240 VAC Supply Voltage • 1-5mA, 4-20mA, 10-50mA, 0-135 ohm • 24 VDC, 120, 240 VAC 0-1000 ohm, 0-5 VDC, 0-10 VDC Standard Inputs • 1-5mA, 4-20mA, 10-50mA, 0-135 ohm, Standard Inputs Temperature Range 0-1000 ohm, 0-5 VDC, 0-10 VDC • 4-20mA, RTD, Thermocouple • -40F to 150F Temperature Range Temperature Range Accessories • -40F to 150F • -40F to 150F • Analog output module Accessories Accessories Applications • Analog output module • Analog output, 24VDC power supply • Position control for rotary electric actuators to control valves and dampers. Applications Applications • High performance control for Qtr-turn and • Direct process control (P.I.D.) for flow, tem- Multi-turn rotary electric actuators for modu- perature, pressure, level and Ph applications. lating control of valves and dampers. Primary industires: Food & beverage, OEM, Industrial & Automotive

Get more information: Get more information: Get more information: Product brochure: Product brochure: Product brochure: • WCABR1000 • WCENBR1021 • WCENBR1021

IOM: IOM: IOM: • WCAIM 2031 • WCAIM2037 • WCENIM2026 • WCAIM2050 See page 2. See page 2. See page 2. 15 www.flowserve.com Flowserve Corporation Flow Control 1978 Foreman Drive Cookeville, Tennessee 38501 Phone: 931 432 4021 Fax: 931 432 3105 www.flowserve.com

To find your local Flowserve representative, visit www.flowserve.com or call USA 1 800 225 6989

FCD WCENBR0001-05 03/18 Printed in USA. Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application.

While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimen- sions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices.

© 2007 Flowserve Corporation, Irving, Texas, USA. Flowserve is a registered trademark of Flowserve Corporation.

flowserve.com