Installation Instructions and Use and Care Guide
Total Page:16
File Type:pdf, Size:1020Kb
Installation Instructions and Use and Care Guide 30" (76.2 cm) 36" (91.4 cm) Retractable (Pop-up) Downdraft Vent Systems IMPORTANT: Quick Reference Table of Contents: Read and save Pages 2 Before you start these instructions. 3 Electrical requirements 4 Product dimensions 4 Cabinet dimensions IMPORTANT: 5 Countertop cutout dimensions Installer: Leave Installation Instructions with 6 Vent system requirements the homeowner. Interior-mounted vent motor Homeowner: Keep Installation Instructions for 7- 9 Installation steps future reference. 9 Vent system requirements Save Installation Instructions for local electrical Exterior-mounted vent motor inspector's use. 10 - 11 Installation steps 12 Use and Care Information Part No. 4329225/9763381 13 Accessories Mobile home installation Parts supplied Before you start... The installation of this downdraft vent system must conform to the for installation: Your safety and the safety of Manufactured Home Construction others are very important. Safety Standards, Title 24 CFR, Part 328 (formerly the Federal We have provided many important Standard for Mobile Home safety messages in this manual Construction and Safety, Title 24, and on your appliance. Always HUD, Part 280) or when such read and obey all safety standard is not applicable, the messages. Standard for Manufactured Home This is the safety alert Installation 1982 (Manufactured • 1 top trim symbol. Home Sites, Communities and • 2 end caps This symbol alerts you to Setups) ANSI A225.1/NFPA 501A*, • 2 lower support legs potential hazards that can kill or or latest edition, or with local • 2 overcounter support brackets hurt you and others. codes. • 2 undercounter mounting brackets • 1 bag of fasteners All safety messages will follow the All openings in the wall or floor • 1 metal cover safety alert symbol and either the where retractable downdraft vent • 1 backdraft damper word “DANGER” or “WARNING”. is to be installed must be sealed. • literature package These words mean: Electrical ground is required. See • optional support and two screws (36" (91.4 cm) models only DANGER “Electrical requirements,” page 3. When installing downdraft vent, You can be killed or seriously the cabinet drawer will need to be injured if you don’t immediately removed and the drawer front Parts needed follow instructions. installed permanently to cabinet. for installation: NOTE: Downdraft vent is installed WARNING • 2 U.L.- or C.S.A.-listed 1/2" (12.7 mm) directly behind the cooktop. Install conduit connectors (3 are required if You can be killed or seriously downdraft vent first. the exterior-mounted vent motor injured if you don’t follow Cabinet construction: Downdraft is used.) instructions. vent is designed for use in a • 1 wall cap for interior-mounted All safety messages will tell you cabinet with a depth of 24" motor what the potential hazard is, tell you • vent system (61 cm). Some installations • power supply cable how to reduce the chance of injury, require a countertop deeper than • wiring cable for optional remote and tell you what can happen if the 25" (63.5 cm). See chart on page 5. blower kit. instructions are not followed. The maximum depth of the overhead cabinet is 13" (33 cm). IMPORTANT: Observe all governing Overhead cabinets installed at codes and ordinances. either side of the downdraft vent Tools needed for Failure to meet codes and must be 18" (45.7 cm) above the cooking surface. installation: ordinances could lead to fire or • safety glasses See cooktop Installation electrical shock. • gloves Instructions before making any Proper installation is your cutouts and for the minimum • jig or keyhole saw responsibility. Make sure you have distance between the front edge • drill with 1/8" drill bit everything necessary for correct of the countertop and front edge • pencil installation. It is the responsibility of cooktop. The minimum • measuring tape of the installer to comply with the horizontal distance between the • flat-blade screwdriver installation clearances specified on overhead cabinets is the same as • Phillips screwdriver the model/serial rating plate. The the width of the installed • 3/8" (9.5 mm) nut driver or ratchet model/serial rating plate is located downdraft vent. • level on the front of the downdraft vent • pliers above the wiring box cover. When installing a 36" (91.4 cm) retractable downdraft vent with • metal snips Check location where downdraft “Create-A-Cooktop” modules, the • wire stripper or utility knife vent will be installed. The location optional support must be installed • caulking gun and weatherproof caulk should be away from strong draft on the front of the downdraft vent. • duct tape areas, such as windows, doors and See installation steps for details. strong heating vents or fans. Before making countertop cutout, check that downdraft vent and cooktop location will clear cabinet walls, backsplash, and rear wall studs inside cabinet. 2 Electrical requirements IMPORTANT: Observe all governing codes and ordinances. C. Wire sizes and connections E. A U.L.- or C.S.A.-listed, 1/2" must conform to the (12.7 mm) conduit connector It is the customer’s responsibility: requirements of the National must be provided at each end of • To contact a qualified electrical Electrical Code, ANSI/NFPA 70 — the power supply cable (at the installer. latest edition*, or CSA Standards downdraft vent and at the C22.1-94, Canadian Electrical junction box). • To assure that the electrical Code, Part 1 and C22.2 No. 0-M91 installation is adequate and in - latest edition** and all local conformance with National codes and ordinances. A wiring diagram is located Electrical Code, ANSI/NFPA 70 F. on the downdraft vent base — latest edition*, or CSA above the wiring box cover. Standards C22.1-94, Canadian WARNING — TO REDUCE THE Electrical Code, Part 1 and RISK OF FIRE, ELECTRIC C22.2 No. 0-M91 - latest SHOCK, OR INJURY TO Copies of the standards listed may be edition** and all local codes PERSONS, OBSERVE THE obtained from: and ordinances. FOLLOWING: * National Fire Protection Association If codes permit and a separate Installation work and electrical One Batterymarch Park ground wire is used, it is wiring must be done by qualified Quincy, Massachusetts 02269 recommended that a qualified person(s) in accordance with all **CSA International electrician determine that the applicable Codes and Standards, 8501 East Pleasant Valley Road ground path is adequate. including fire related construction. Cleveland, Ohio 44131-5575 Do not ground to a gas pipe. Sufficient air is needed for proper combustion and exhausting of Check with a qualified electrician if gases through the flue (chimney) you are not sure downdraft vent is of fuel burning equipment to properly grounded. prevent back drafting. Follow the Do not have a fuse in the neutral heating equipment or ground circuit. manufacturer’s guideline and safety standards such as those IMPORTANT: Save Installation published by the National Fire instructions for electrical Protection Association inspector’s use. (NFPA),and the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When cutting or drilling into wall A. A 120-volt, 60-Hz, AC-only, or ceiling, do not damage fused electrical supply is required electrical wiring and other hidden on a separate 15 amp circuit. A utilities. time-delay fuse or circuit breaker Ducted fans must always be is recommended. The fuse must vented to the outdoors. be sized per local codes in accordance with the electrical WARNING — To reduce the risk of fire, use only metal ductwork. rating of the downdraft vent as specified on the model/serial This unit must be grounded. rating plate located on the front of the downdraft vent above the wiring box cover. D. This downdraft vent should be connected directly to the fused disconnect (or circuit breaker) B. The downdraft vent must through flexible, armored or non- be connected with copper wire metallic sheathed, copper cable. only. Allow some slack in the cable so the downdraft vent can be moved if servicing is ever necessary. 3 Product dimensions top trim widths 30" vent (76.2 cm) 36" vent (91.4 cm) 8-1/4" (21 cm) retractable vent height 4" (10.2 cm) 1-1/2" (3.8 cm) 16" (40.6 cm) 27" (68.6 cm) for 30" (76.2 cm) vent 3/8" (9.5 mm) 33" (83.8 cm) for 36" (91.4 cm) vent 8" (20.3 cm) 26-1/8" 5/8" (66.4 cm) 3-1/4"x 10" 9" (22.9 cm) Dia. (15.9 mm) (8.3 cm x 25.4 cm) NOTE: A 10" (2.5 16" cm) round vent (40.6 cm) system adapter 8" collar attaches over (20,3 cm) this hole. Adapter collar is supplied 16" 5/8" with exterior (40.6 cm) (15.9 mm) blower. 16" (40.6 cm) EXTERIOR-MOUNTED 2-1/8” BLOWER MOTOR INTERNAL (54 cm) BLOWER 9-3/8" MOTOR (23.8 cm) Cabinet dimensions 4-1/8"+A (10.5 cm) See cooktop manufacturer’s instructions for cooktop cutout A = 1/2" (12.7 mm) depth and width. min. Use dimensions for vent system cutout location that applies to 23-9/16" your installation. (59.8 cm) 17-9/16" (44.6 cm) 17-3/16" (43.7 cm) all cutouts are for 3/8" 3-1/4" x 10" (9.5 mm) Vent system cutout dimensions for internal (8.3 cm x 25.4 cm) blower models only. vent system Exterior mounted blower systems connect with 10" (25.4 cm) round vent. The cutout Locate power supply locations for this vent system will depend junction box at lower upon your specific installation. right hand rear corner of cabinet. centerline of cooktop cutout 4 Countertop cutout dimensions 1-7/8" 27-1/2" (69.9 cm) for 30" (76.2 cm) vent (4.8 cm) 33-1/2" (85.1 cm) for 36" (91.4 cm) vent Some models require a countertop deeper than 1/4" 25" (63.5 cm); see cutout (6.4 mm) dimensions chart below.