3/9/2021 ALLDATA Repair 2015 Mercedes Benz Truck GL 450 4MATIC (166.864) V6-3.0L Turbo (276.821) THE POSITION OF THE ( BANK 1) IS IMPLAUSIBLE RELATIVE TO THE POSITION OF THE . THERE IS A SIGNAL ABOVE THE PERMISSIBLE LIMIT VALUE.

The position of the intake camshaft (cylinder bank 1) is implausible relative to the position of the crankshaft. There is a signal above the permissible limit value.

The position of the camshaft is implausible compared with the position of the crankshaft.

Test prerequisite

No error code for component 'B6/4 (Left intake camshaft Hall sensor)' is present. No error code for component 'B6/5 (Right intake camshaft Hall sensor)' is present. No error code for component 'B6/6 (Left exhaust camshaft Hall sensor)' is present. No error code for component 'B6/7 (Right exhaust camshaft Hall sensor)' is present. No error code for component 'B70 (Crankshaft Hall sensor)' is present. No fault in camshaft adjustment present.

Test procedure

Start combustion engine and allow to idle.

Status of associated actual values

Observe Type Converter from ° to ° of the following value: Float32ResponseParameter 'PRES_Nockenwellen_Auslass_Bank_2' (Position of exhaust camshaft of left cylinder bank) to the service 'DT_Nockenwellensteller_Auslass_Links' (Position of exhaust camshaft of left cylinder bank) (min: Linear Converter from ° to °: x - > 1.0 * x + -7.5 of the following value: Float32ResponseParameter 'PRES_Sollwinkel_Auslassventil_Bank_2' (Position of exhaust camshaft of left cylinder bank ( Specified value )) to the service 'DT_Nockenwellenwinkel_Sollwert_Auslass_Links' (Position of exhaust camshaft of left cylinder bank ( Specified value ))) (max: Linear Converter from ° to °: x -> 1.0 * x + 7.5 of the following value: Float32ResponseParameter 'PRES_Sollwinkel_Auslassventil_Bank_2' (Position of exhaust camshaft of left cylinder bank ( Specified value )) to the service 'DT_Nockenwellenwinkel_Sollwert_Auslass_Links' (Position of exhaust camshaft of left cylinder bank ( Specified value ))) Observe Type Converter from ° to ° of the following value: Float32ResponseParameter 'PRES_DOP_LABEL_wnwa_w' (Position of exhaust camshaft of right cylinder bank) to the service 'DT_Nockenwellensteller_Auslass_Rechts' (Position of exhaust camshaft of right cylinder bank) (min: Linear Converter from ° to °: x -> 1.0 * x + -7.5 of the following value: Float32ResponseParameter 'PRES_Sollwinkel_Auslassventil_Bank_1' (Position of exhaust camshaft of right cylinder bank ( Specified value )) to the service 'DT_Nockenwellenwinkel_Sollwert_Auslass_Rechts' (Position of exhaust camshaft of right cylinder bank ( Specified value ))) (max: Linear Converter from ° to °: x -> 1.0 * x + 7.5 of the following value: Float32ResponseParameter 'PRES_Sollwinkel_Auslassventil_Bank_1' (Position of exhaust camshaft of right cylinder bank ( Specified value )) to the service 'DT_Nockenwellenwinkel_Sollwert_Auslass_Rechts' (Position of exhaust camshaft of right cylinder bank ( Specified value ))) Observe Type Converter from ° to ° of the following value: Float32ResponseParameter 'PRES_Nockenwellen_Einlass_Bank_2' (Position of intake camshaft of left cylinder bank) to the service 'DT_Nockenwellenwinkel_Einlass_Links' (Position of intake camshaft of left cylinder bank) (min: Linear Converter from ° to °: x -> 1.0 * x + -7.5 of the following value: Float32ResponseParameter 'PRES_Sollwinkel_Einlassventil_Bank_2' (Position of intake camshaft of left cylinder bank ( Specified value )) to the service 'DT_Nockenwellenwinkel_Sollwert_Einlass_Links' (Position of intake camshaft of left cylinder bank ( Specified value ))) (max: Linear Converter from ° to °: x -> 1.0 * x + 7.5 of the following value: Float32ResponseParameter 'PRES_Sollwinkel_Einlassventil_Bank_2' (Position of intake camshaft of left cylinder bank ( Specified value )) to the service 'DT_Nockenwellenwinkel_Sollwert_Einlass_Links' (Position of intake camshaft of left cylinder bank ( Specified value ))) Observe Type Converter from ° to ° of the following value: Float32ResponseParameter 'PRES_Nockenwellen_Einlass_Bank_1' (Position of intake camshaft of right cylinder bank) to the service 'DT_Nockenwellenwinkel_Einlass_Rechts' (Position of intake camshaft of right cylinder bank) (min: Linear Converter from ° to °: x -> 1.0 * x + -7.5 of the following value: Float32ResponseParameter 'PRES_Sollwinkel_Einlassventil_Bank_1' (Position of intake camshaft of right cylinder bank ( Specified value )) to the service 'DT_Nockenwellenwinkel_Sollwert_Einlass_Rechts' (Position of intake camshaft of right cylinder bank ( Specified value ))) (max: Linear Converter from ° to °: x -> 1.0 * x + 7.5 of the following value: Float32ResponseParameter 'PRES_Sollwinkel_Einlassventil_Bank_1' (Position of intake camshaft of right cylinder bank ( Specified value )) to the service 'DT_Nockenwellenwinkel_Sollwert_Einlass_Rechts' (Position of intake camshaft of right cylinder bank ( Specified value )))

Question

Are the actual values OK? Yes No https://my.alldata.com/repair/#/repair/article/55303/guid/na-mb2012-2019166-MED17_7_V6LA_15941_html 1/2 3/9/2021 ALLDATA Repair

https://my.alldata.com/repair/#/repair/article/55303/guid/na-mb2012-2019166-MED17_7_V6LA_15941_html 2/2