Fibre Channel SAN Configuration Guide ESX 4.0 Esxi 4.0 Vcenter Server 4.0
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Clustered Data ONTAP® 8.3 SAN Configuration Guide
Updated for 8.3.1 Clustered Data ONTAP® 8.3 SAN Configuration Guide NetApp, Inc. Telephone: +1 (408) 822-6000 Part number: 215-10114_A0 495 East Java Drive Fax: +1 (408) 822-4501 June 2015 Sunnyvale, CA 94089 Support telephone: +1 (888) 463-8277 U.S. Web: www.netapp.com Feedback: [email protected] Table of Contents | 3 Contents Considerations for iSCSI configurations .................................................... 5 Ways to configure iSCSI SAN hosts with single nodes .............................................. 5 Ways to configure iSCSI SAN hosts with HA pairs ................................................... 7 Benefits of using VLANs in iSCSI configurations ..................................................... 8 Static VLANs .................................................................................................. 8 Dynamic VLANs ............................................................................................. 9 Considerations for FC configurations ...................................................... 10 Ways to configure FC SAN hosts with single nodes ................................................. 10 Ways to configure FC with HA pairs ........................................................................ 12 FC switch configuration best practices ..................................................................... 13 Supported number of FC hop counts ......................................................................... 13 Supported FC ports ................................................................................................... -
Sun Storage 16 Gb Fibre Channel Pcie Host Bus Adapter, Emulex Installation Guide for HBA Model 7101684
Sun Storage 16 Gb Fibre Channel PCIe Host Bus Adapter, Emulex Installation Guide For HBA Model 7101684 Part No: E24462-10 August 2018 Sun Storage 16 Gb Fibre Channel PCIe Host Bus Adapter, Emulex Installation Guide For HBA Model 7101684 Part No: E24462-10 Copyright © 2017, 2018, Oracle and/or its affiliates. All rights reserved. This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering, disassembly, or decompilation of this software, unless required by law for interoperability, is prohibited. The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report them to us in writing. If this is software or related documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, then the following notice is applicable: U.S. GOVERNMENT END USERS: Oracle programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, delivered to U.S. Government end users are "commercial computer software" pursuant to the applicable Federal Acquisition Regulation and agency-specific supplemental regulations. As such, use, duplication, disclosure, modification, and adaptation of the programs, including any operating system, integrated software, any programs installed on the hardware, and/or documentation, shall be subject to license terms and license restrictions applicable to the programs. -
SAS Enters the Mainstream Although Adoption of Serial Attached SCSI
SAS enters the mainstream By the InfoStor staff http://www.infostor.com/articles/article_display.cfm?Section=ARTCL&C=Newst&ARTICLE_ID=295373&KEYWORDS=Adaptec&p=23 Although adoption of Serial Attached SCSI (SAS) is still in the infancy stages, the next 12 months bode well for proponents of the relatively new disk drive/array interface. For example, in a recent InfoStor QuickVote reader poll, 27% of the respondents said SAS will account for the majority of their disk drive purchases over the next year, although Serial ATA (SATA) topped the list with 37% of the respondents, followed by Fibre Channel with 32%. Only 4% of the poll respondents cited the aging parallel SCSI interface (see figure). However, surveys of InfoStor’s readers are skewed by the fact that almost half of our readers are in the channel (primarily VARs and systems/storage integrators), and the channel moves faster than end users in terms of adopting (or at least kicking the tires on) new technologies such as serial interfaces. Click here to enlarge image To get a more accurate view of the pace of adoption of serial interfaces such as SAS, consider market research predictions from firms such as Gartner and International Data Corp. (IDC). Yet even in those firms’ predictions, SAS is coming on surprisingly strong, mostly at the expense of its parallel SCSI predecessor. For example, Gartner predicts SAS disk drives will account for 16.4% of all multi-user drive shipments this year and will garner almost 45% of the overall market in 2009 (see figure on p. 18). -
Gen 6 Fibre Channel Technology
WHITE PAPER Better Performance, Better Insight for Your Mainframe Storage Network with Brocade Gen 6 TABLE OF CONTENTS Brocade and the IBM z Systems IO product team share a unique Overview .............................................................. 1 history of technical development, which has produced the world’s most Technology Highlights .................................. 2 advanced mainframe computing and storage systems. Brocade’s Gen 6 Fibre Channel Technology technical heritage can be traced to the late 1980s, with the creation of Benefits for z Systems and Flash channel extension technologies to extend data centers beyond the “glass- Storage ................................................................ 7 house.” IBM revolutionized the classic “computer room” with the invention Summary ............................................................. 9 of the original ESCON Storage Area Network (SAN) of the 1990s, and, in the 2000s, it facilitated geographically dispersed FICON® storage systems. Today, the most compelling innovations in mainframe storage networking technology are the product of this nearly 30-year partnership between Brocade and IBM z Systems. As the flash era of the 2010s disrupts between the business teams allows both the traditional mainframe storage organizations to guide the introduction networking mindset, Brocade and of key technologies to the market place, IBM have released a series of features while the integration between the system that address the demands of the data test and qualification teams ensures the center. These technologies leverage the integrity of those products. Driving these fundamental capabilities of Gen 5 and efforts are the deep technical relationships Gen 6 Fibre Channel, and extend them to between the Brocade and IBM z Systems the applications driving the world’s most IO architecture and development teams, critical systems. -
FICON Native Implementation and Reference Guide
Front cover FICON Native Implementation and Reference Guide Architecture, terminology, and topology concepts Planning, implemention, and migration guidance Realistic examples and scenarios Bill White JongHak Kim Manfred Lindenau Ken Trowell ibm.com/redbooks International Technical Support Organization FICON Native Implementation and Reference Guide October 2002 SG24-6266-01 Note: Before using this information and the product it supports, read the information in “Notices” on page vii. Second Edition (October 2002) This edition applies to FICON channel adaptors installed and running in FICON native (FC) mode in the IBM zSeries procressors (at hardware driver level 3G) and the IBM 9672 Generation 5 and Generation 6 processors (at hardware driver level 26). © Copyright International Business Machines Corporation 2001, 2002. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . vii Trademarks . viii Preface . ix The team that wrote this redbook. ix Become a published author . .x Comments welcome. .x Chapter 1. Overview . 1 1.1 How to use this redbook . 2 1.2 Introduction to FICON . 2 1.3 zSeries and S/390 9672 G5/G6 I/O connectivity. 3 1.4 zSeries and S/390 FICON channel benefits . 5 Chapter 2. FICON topology and terminology . 9 2.1 Basic Fibre Channel terminology . 10 2.2 FICON channel topology. 12 2.2.1 Point-to-point configuration . 14 2.2.2 Switched point-to-point configuration . 15 2.2.3 Cascaded FICON Directors configuration. 16 2.3 Access control. 18 2.4 Fibre Channel and FICON terminology. -
Serial Attached SCSI (SAS)
Storage A New Technology Hits the Enterprise Market: Serial Attached SCSI (SAS) A New Interface Technology Addresses New Requirements Enterprise data access and transfer demands are no longer driven by advances in CPU processing power alone. Beyond the sheer volume of data, information routinely consists of rich content that increases the need for capacity. High-speed networks have increased the velocity of data center activity. Networked applications have increased the rate of transactions. Serial Attached SCSI (SAS) addresses the technical requirements for performance and availability in these more I/O-intensive, mission-critical environments. Still, IT managers are pressed on the other side by cost constraints and the need White paper for flexibility and scalability in their systems. While application requirements are the first measure of a storage technology, systems based on SAS deliver on this second front as well. Because SAS is software compatible with Parallel SCSI and is interoperable with Serial ATA (SATA), SAS technology offers the ability to manage costs by staging deployment and fine-tuning a data center’s storage configuration on an ongoing basis. When presented in a small form factor (SFF) 2.5” hard disk drive, SAS even addresses the increasingly important facility considerations of space, heat, and power consumption in the data center. The backplanes, enclosures and cabling are less cumbersome than before. Connectors are smaller, cables are thinner and easier to route impeding less airflow, and both SAS and SATA HDDs can share a common backplane. White paper Getting this new technology to the market in a workable, compatible fashion takes various companies coming together. -
Fibre Channel and Iscsi Configuration Guide for the Data ONTAP® 8.0 Release Family
Fibre Channel and iSCSI Configuration Guide for the Data ONTAP® 8.0 Release Family NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web: www.netapp.com Feedback: [email protected] Part number: 215-08164_A0 August 2013 Table of Contents | 3 Contents iSCSI configurations .................................................................................... 6 Single-network HA pair in an iSCSI SAN .................................................................. 6 Multi-network HA pair in an iSCSI SAN ................................................................... 7 Direct-attached single-controller configurations in an iSCSI SAN ............................ 8 VLANs for iSCSI configurations ................................................................................ 9 Static VLANs ................................................................................................ 10 Dynamic VLANs ........................................................................................... 10 Fibre Channel configurations .................................................................... 11 FC onboard and expansion port combinations .......................................................... 11 Fibre Channel supported hop count .......................................................................... 12 Fibre Channel supported speeds ................................................................................ 13 Fibre Channel switch -
Microsoft SQL Server 2008 DSS Performance with Fcoe, Iscsi, And
Technical Report Evaluating the Performance of FCoE, iSCSI, and FC Using DSS Workloads with Microsoft SQL Server 2008 Wei Liu, NetApp Kent Swalin, Vinay Kulkarni, IBM Scott Hinckley, Emulex June 2010 | TR-3853 ABSTRACT This technical report describes a series of tests performed by NetApp and IBM with support from Emulex to compare the performance of different storage protocols (FCoE, iSCSI, and Fibre Channel) using Decision Support System (DSS) workloads with Microsoft® SQL Server® 2008 on IBM x3850 X5 server, NetApp® FAS3070 storage systems, and Emulex adapters. TABLE OF CONTENTS 1 EXECUTIVE SUMMARY ............................................................................................................. 3 2 INTRODUCTION ......................................................................................................................... 3 3 TEST ENVIRONMENT ................................................................................................................ 3 3.1 IBM SYSTEM 3850 X5 SERVER ................................................................................................................. 4 3.2 EMULEX LPe12002-M8 HBA ...................................................................................................................... 5 3.3 EMULEX OCe10102 CNA ........................................................................................................................... 5 3.4 NETAPP FAS3070 STORAGE ................................................................................................................... -
EMC’S Perspective: a Look Forward
The Performance Impact of NVM Express and NVM Express over Fabrics PRESENTATION TITLE GOES HERE Live: November 13, 2014 Presented by experts from Cisco, EMC and Intel Webcast Presenters J Metz, R&D Engineer for the Office of the CTO, Cisco Amber Huffman, Senior Principal Engineer, Intel Steve Sardella , Distinguished Engineer, EMC Dave Minturn, Storage Architect, Intel SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies and individual members may use this material in presentations and literature under the following conditions: Any slide or slides used must be reproduced in their entirety without modification The SNIA must be acknowledged as the source of any material used in the body of any document containing material from these presentations. This presentation is a project of the SNIA Education Committee. Neither the author nor the presenter is an attorney and nothing in this presentation is intended to be, or should be construed as legal advice or an opinion of counsel. If you need legal advice or a legal opinion please contact your attorney. The information presented herein represents the author's personal opinion and current understanding of the relevant issues involved. The author, the presenter, and the SNIA do not assume any responsibility or liability for damages arising out of any reliance on or use of this information. NO WARRANTIES, EXPRESS OR IMPLIED. USE AT YOUR OWN RISK. 3 What This Presentation Is A discussion of a new way of talking to Non-Volatile -
Product Manual: Ultrastar DC HC620 (Hs14) SAS OEM
Hard disk drive specifications Ultrastar® DC HC620 (previously known as Ultrastar Hs14 14TB/15TB) 3.5 inch Serial Attached SCSI hard disk drive Model: HSH721414AL52M0/4 HSH721414AL42M0/4 HSH721415AL52M0/4 HSH721415AL42M0/4 Revision 1.6 31 January 2020 1 Hard Disk Drive Specification Publication Disclaimer Information One MB is equal to one million bytes, one GB is equal to one billion bytes and one TB equals 1,000GB (one trillion bytes) when referring to storage capacity. Accessible capacity will vary from the stated capacity due to formatting and partitioning of the drive, the computer’s operating system, and other factors. The following paragraph does not apply to any jurisdiction where such provisions are inconsistent with local law: THIS PUBLICATION IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. There may be improvements or changes in any products or programs described in this publication at any time. It is possible that this publication may contain reference to, or information about, Western Digital products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Western Digital Corporation intends to announce such Western Digital products, programming, or services in your country. Technical information about this product is available by contacting your local Western Digital product representative or on the Internet at: [email protected]. -
Comparing Fibre Channel, Serial Attached SCSI (SAS) and Serial ATA (SATA)
Comparing Fibre Channel, Serial Attached SCSI (SAS) and Serial ATA (SATA) by Allen Hin Wing Lam Bachelor ofElectrical Engineering Carleton University 1996 PROJECT SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF MASTER OF ENGINEERING In the School ofEngineering Science © Allen Hin Wing Lam 2009 SIMON FRASER UNIVERSITY Fall 2009 All rights reserved. However, in accordance with the Copyright Act ofCanada, this work may be reproduced, without authorization, under the conditions for Fair Dealing. Therefore, limited reproduction ofthis work for the purposes ofprivate study, research, criticism, review and news reporting is likely to be in accordance with the law, particularly ifcited appropriately. Approval Name: Allen Hin Wing Lam Degree: Master ofEngineering Title ofProject: Comparing Fibre Channel, Serial Attached SCSI (SAS) and Serial ATA (SATA) Examining Committee: Chair: Dr. Daniel Lee Chair ofCommittee Associate Professor, School ofEngineering Science Simon Fraser University Dr. Stephen Hardy Senior Supervisor Professor, School ofEngineering Science Simon Fraser University Jim Younger Manager, Product Engineering PMC- Sierra, Inc. Date ofDefence/Approval r 11 SIMON FRASER UNIVERSITY LIBRARY Declaration of Partial Copyright Licence The author, whose copyright is declared on the title page of this work, has granted to Simon Fraser University the right to lend this thesis, project or extended essay to users of the Simon Fraser University Library, and to make partial or single copies only for such users or in response -
Brocade G620 Switch Datasheet
DATA SHEET Brocade G620 Switch Ultra-dense, Highly Scalable, Easy-to-Use Enterprise-Class Storage Networking Switch HIGHLIGHTS Today’s mission-critical storage environments require greater • Provides high scalability in an ultra- consistency, predictability, and performance to keep pace with growing dense, 1U, 64-port switch to support business demands. Faced with explosive data growth, data centers high-density server virtualization, need more IO capacity to accommodate the massive amounts of data, cloud architectures, and flash-based applications, and workloads. In addition to this surge in data, collective storage environments expectations for availability continue to rise. Users expect applications to • Increases performance for demanding workloads across 32 Gbps links and be available and accessible from anywhere, at any time, on any device. shatters application performance barriers with up to 100 million IOPS To meet these dynamic and growing The Brocade® G620 Switch meets the • Enables “pay-as-you-grow” business demands, organizations need to demands of hyper-scale virtualization, scalability—with 24 to 64 ports—for deploy and scale up applications quickly. larger cloud infrastructures, and growing on-demand flexibility As a result, many are moving to higher flash-based storage environments by • Provides proactive, non-intrusive, Virtual Machine (VM) densities to enable delivering market-leading Gen 6 Fibre real-time monitoring and alerting of rapid deployment of new applications Channel technology and capabilities. It storage IO health and performance and deploying flash storage to help those provides a high-density building block for with IO Insight, the industry’s first applications scale to support thousands increased scalability, designed to support integrated network sensors of users.