Deployment and Configuration Guide EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays

Abstract This document provides guidance on host and switching devices that are validated for use with Dell EMC SC Series, Dell PS Series, and Dell FS Series (FluidFS) storage solutions.

May 2021

DSCM Table of contents

Table of contents 1 Overview ...... 5 1.1 Definitions ...... 5 1.2 Abbreviations and Terminology ...... 5 1.3 Conventions used in this document ...... 7 2 Dell Storage support policy statement ...... 8 2.1 Level 1: Full contractual support ...... 8 2.2 Level 2: Conditional support ...... 8 2.3 Level 3: Commercially reasonable effort ...... 9 2.4 Level 4: No support ...... 9 2.5 Support for cross-platform coexisting solutions ...... 9 2.6 FS Series additional support statement ...... 10 2.6.1 Switch support policy ...... 10 2.6.2 Client OS environment support policy ...... 11 2.6.3 MD Series support policy statement ...... 11 2.7 Other statements ...... 11 2.7.1 Operating system, switch, and server adapter settings...... 11 2.7.2 Server interoperability ...... 12 2.7.3 Host connectivity adapters and server vendor support ...... 12 2.7.4 Persistent FCIDs...... 12 2.7.5 Limits of supportability ...... 12 3 Switches ...... 13 3.1 Switches (SC, SCv, and FS Series) ...... 13 3.2 Fibre channel over Ethernet Switches (SC Series) ...... 14 3.3 iSCSI Switches ...... 15 3.3.1 1/10 iSCSI Switches (SC, SCv, and FS Series) ...... 15 3.3.2 25/100Gb iSCSI Switches (SC, SCv Series) ...... 16 3.3.3 1/10Gb Switches (PS Series) ...... 17 3.4 iSCSI over DCB support (SC, SCv and PS Series) ...... 24 4 Host connectivity ...... 29 4.1 Required Adapter and Server OS Settings ...... 29 4.2 Fibre Channel Adapters (SC and SCv Series) ...... 30 4.3 iSCSI Adapters ...... 67 4.3.1 iSCSI converged network and host bus adapters (SC and SCv Series)...... 67 4.3.2 Software iSCSI initiators (SC and SCv Series) ...... 75 4.3.3 iSCSI converged network and host bus adapters (PS Series) ...... 80

2 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Table of contents

4.3.4 Network interface cards for boot from SAN and DCB support for iSCSI (PS Series) ...... 87 4.3.5 Software iSCSI initiators (PS Series) ...... 90 4.4 SAS Adapters (SC and SCv Series)...... 92 4.5 Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series) ...... 100 4.5.1 FCoE converged network and host bus adapters (SC, SCv Series) ...... 100 4.5.2 Software FCoE initiators (SC and SCv Series) ...... 105 5 Other support matrices ...... 106 5.1 Cisco UCS support ...... 106 5.2 appliances ...... 106 5.3 KMS solutions ...... 106 5.4 Data Protection ...... 107 A Required Adapter and Server OS Settings ...... 108 A.1 Adapter Settings ...... 108 A.1.1 Cisco Fibre Channel Adapters ...... 108 A.1.2 Emulex Fibre Channel Adapters ...... 108 A.1.3 QLogic Fibre Channel Adapters (and re-branded adapters based on QLogic) ...... 109 A.2 Server OS Settings ...... 110 A.2.1 Windows Server 2008r2 ...... 110 A.2.2 Windows Server 2012 and Later ...... 116 A.2.3 Linux (Red Hat, SuSE, Oracle, Ubuntu) ...... 122 A.2.4 VMware ...... 125 A.2.5 Oracle Solaris ...... 126 A.2.6 IBM AIX ...... 127 A.2.7 Citrix Hypervisor (XenServer) ...... 128 A.2.8 HP-UX 11i ...... 129 B SC and SCv Fibre Channel Zoning ...... 130 C Deprecated devices ...... 131 C.1 Host configurations ...... 131 C.1.1 SC Series ...... 131 C.1.2 PS Series ...... 141 C.2 Deprecated switches ...... 145 C.2.1 SC Series and PS Series ...... 145 C.2.2 FS Series ...... 147 D Technical support and additional resources ...... 148 D.1 Related documentation ...... 148 D.2 RPQ process ...... 148

3 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Table of contents

The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose.

Use, copying, and distribution of any software described in this publication requires an applicable software license.

This document may contain certain words that are not consistent with Dell's current language guidelines. Dell plans to update the document over subsequent future releases to revise these words accordingly.

This document may contain language from third party content that is not under Dell's control and is not consistent with Dell's current guidelines for Dell's own content. When such third party content is updated by the relevant third parties, this document will be revised accordingly.

Copyright © 2015–2021 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. [4/23/2020] [Deployment and Configuration Guide] [DSCM]

4 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Overview

1 Overview This compatibility matrix describes SAN components (such as switches, host bus Adapters, and operating systems) that have been tested in Dell storage labs. The testing results demonstrate that Dell SC Series, PS Series, and FS Series products, as tested and under normal operating conditions, will operate as expected and as described in Dell Storage product documentation.

The first portion of this document describes the Dell commitment to supporting the various products that have been tested and those products or components that have not been tested. This section describes a multi- tiered support policy that describes any limitations to a customer’s supportability for Dell and non- Dell components when those components or their constituent software (such as drivers and firmware) are not listed in this matrix.

The second part of this document lists switches that have been tested and confirmed to be interoperable with Dell SC Series, PS Series, and FS Series products. The resulting configurations are separated by networking technology (Fibre Channel or Ethernet) and product vendor/model.

The final section of this document details the hardware and software used when testing different host network connectivity devices (network interface controllers, converged network Adapters, and host bus Adapters) and storage initiators in a variety of operating-system environments. The results are separated by protocol and then grouped by operating system.

1.1 Definitions For the purposes of this document, the following definitions apply:

Storage solution: The end-to-end set of components, such as the operating system, network controller, switch, and switch firmware, and array firmware that permits a host to target communication.

Component: The individual parts of a storage solution in the form of host network interface Adapters, iSCSI initiators, iSCSI host bus Adapters, switches, and arrays.

Comparable models: These can include similar devices based on the same architecture and from the same vendor, or newer firmware versions.

1.2 Abbreviations and Terminology Abbreviations and terminonolgy used in this document are defined below.

Abbreviation Term Descriptions L1, L2, L3 Level 1, Level 2, The support level provided for a particular feature (see Level 3 the section, Dell Storage support policy statement for details) BfS Boot from SAN A general term referring to functionality on a CNA/HBA/NIC to allow bare-metal OS boot from a remote, SAN-based target/LUN/volume CNA Converged A networking device that supports DCB and can manage network Adapter more than one class of network traffic, typically consisting of storage and non- storage traffic types

5 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Overview

Abbreviation Term Descriptions Conv Converged Includes functionality to support FC native and Ethernet Ethernet (DCB) native ports in the same switch to facilitate support for capable switch FC/FCoE/TCP functionality DCB Data Center Used to support converged networking solutions that Bridging host FCoE or iSCSI traffic and TCP/IP traffic simultaneously Eth Ethernet The most common type of general purpose networking defined by a group of standards maintained by the Institute of Electrical and Electronics Engineers (IEEE) FC Fibre Channel A networking technology used in storage networks FCoE Fibre Channel A storage protocol that enables Fibre Channel over Ethernet communication over Ethernet networks FW Firmware Typically, the main operating system for an appliance- type device or component such as a NIC, switch, or other device; typically, not user- interactive, though it may contain subsystems that provide user interaction such as a command line interface HBA Host bus Adapter Indicates a device that provides hardware-based FC/FCoE/iSCSI storage functionality iBFT iSCSI Boot A specific, standards-based BfS technology that supports Firmware Table booting from iSCSI-protocol-based targets; part of the ACPI 3.0 standard MLAG Multi-chassis link General term or specific feature offering by some switch aggregation vendors for switch-to-switch multipath interconnection NA Not applicable This feature or function is not applicable NIC Network interface A networking device that provides Ethernet and optional controller TCP/IP functionality and may or may not provide SAN/network boot functionality; for SAN solutions, this requires a software-based protocol initiator (FCoE/iSCSI) to access SAN remote targets OS Operating system The core software of a system RTM Release to Initial-release version of an operating system from the manufacturing vendor SC/SCOS Storage Center The core software of the SC Series products that Operating System provides all storage and management functionality VLT Virtual Link Proprietary switch-to-switch multipathing solution Trunking provided by certain switch products vPC Virtual Port Proprietary switch-to-switch multipathing solution Channel provided by certain Cisco® network products, specifically Cisco Nexus® products In-box The version included with each release of a given operating system by the vendor OS Operating system The core software of a system

6 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Overview

1.3 Conventions used in this document Blue Text is used for all section titles. When visible in body text or tables, blue text indicates a change or addition from the previous version of the Dell Storage Compatibility Matrix (DSCM).

The remainder of the DSCM is organized by storage network component family starting with section 3. The following hierarchy is used:

• Component class (switch, host connectivity adapters, other components) • Array family (SC, SCv, PS, FS) • Component tables by storage protocol (FC, FCoE, iSCSI, etc.)

7 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Dell Storage support policy statement

2 Dell Storage support policy statement This compatibility matrix details devices that have been tested by Dell storage test labs. While Dell tests on a wide variety of devices, it is impossible to test every device or version for all vendors with which Dell Storage products can interoperate. Therefore, the information presented in this document does not constitute a complete list of what is supportable, but simply a list of what has been specifically tested.

Regardless of the support level (described in the following sections), Dell Storage customers will always be provided full contractual support of their storage solution.

Each row in a table defines a SAN component and the software or firmware that was tested with that component. Each of these entries constitutes a supportable configuration.

Based on this matrix, a customer configuration will be classified into one of three levels of supportability described below. Each level of supportability also references the requirement for designing the SAN subsystem using recommended practices suitable for the each Dell Storage product family. These recommended practices are documented in a variety of technical white papers as well as consolidated in the Dell EqualLogic Configuration Guide and the Dell SC Series knowledge center.

Contact your Dell sales representative with questions about how to classify your proposed configuration.

2.1 Level 1: Full contractual support For tested components listed in this compatibility matrix, (and for the specific firmware or software version listed), Dell will provide solution support under an active Dell ProSupport™ or Copilot support contract, assuming that all other components in the storage solution are also under contracted support with their respective manufacturers and that documented, recommended design best practices are followed.

Note: The exception is that iSCSI switches are not specifically listed in the support matrix. They are however supported if they meet the criteria specified in section 3.3.1.

2.2 Level 2: Conditional support In addition to the component versions tested by Dell and listed in this compatibility matrix, the compatibility of comparable hardware models can be projected based upon the results for the systems actually tested and will be designated as conditionally supported.

Dell will provide full contractual support for the storage solution under an active ProSupport or Copilot support contract, assuming that all components in the storage solution are also under contracted support with their respective manufacturers and that documented, recommended design best practices are followed.

Resolution of functional and/or performance issues may be out of Dell control. In such cases, these issues will need to be addressed by the applicable component or software/firmware vendor. If these issue(s) cannot be resolved in a timely manner by Dell or the component vendor, Dell may require, in its sole discretion and as a condition of continuing support, that the customer replace the component in question with one that was tested and/or will upgrade or downgrade to a supported software version.

8 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Dell Storage support policy statement

Examples of conditional support situations include, but are not limited to:

• If a switch or server Adapter shares the same underlying ASIC or chipset and is from the same vendor as a tested configuration, then it may produce similar results. • If a component is an identical model of a component listed, but differs in firmware or driver version, it may produce similar results for any firmware and/or drivers that are newer than those listed. For example, if version X of software/firmware has been tested and is listed as Level 1, then software/firmware versions newer than version X are expected to work.

Failure of a conditionally supported component to provide the same service level as the similar device listed (unless Dell has communicated end of support or a specific incompatibility for a particular product, firmware, or software version) would be treated as a bug that needs to be fixed by the device or software/firmware vendor.

2.3 Level 3: Commercially reasonable effort Level 3 support applies to components not listed within this compatibility matrix, or instances in which a customer has not or is not willing to apply accepted Dell recommended practices for the specific storage family’s SAN design and implementation. If the customer has an active support contract with the appropriate vendor(s), and an active ProSupport or Copilot support contract, Dell will provide storage solution full contractual support for all Dell branded components and provide commercially reasonable effort (CRE) support for any untested component of the configuration. This support level lasts until such time as it is determined, in Dell’s sole discretion that a problem lies within the untested component or results from the way they interoperate with Dell components.

Dell does not guarantee that issues undertaken on a CRE basis will be resolved in a timely fashion, or at all. There is a possibility that the customer would need to replace an untested component or take the affected system out of production to resolve the issues.

2.4 Level 4: No support Level 4 indicates that the device is not supported in any way for use with the specified array family as listed. While this is not a common occurrence, there are situations where specific features or functions required to support the array are not available in the device listed.

2.5 Support for cross-platform coexisting solutions Cross-platform coexisting solutions are defined as SAN environments that host more than one storage platform technology. In general, this could be two or more array technology solutions from the same vendor or different vendors. Examples include:

• A SAN solution that is hosting a Dell SC Series array as well as an EMC array solution, while sharing the same network resources • A SAN solution that is hosting a Dell SC Series array as well as a Dell PS Series array solution, while sharing the same network resources

Dell supports the following scenarios involving two or more array solutions sharing a common network infrastructure:

9 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Dell Storage support policy statement

• A Dell PS Series SAN infrastructure introducing or adding a Dell SC Series array solution to the existing PS Series SAN

Note: Any other array coexistence solution is not supported at the time of the publish date of this document.

This scenario implies that certain criteria will be assumed and only these configurations will receive Level 1 support:

• iSCSI only • A single IP subnet • PS Series Host Integration Tools may (or may not) be installed on individual hosts where supported

To determine the support level of the coexistence solution, the following rules apply:

• Level 1 support is provided, assuming that for each array solution (PS Series and SC Series), all of the components used (operating systems, Adapters, and switches) are listed in the matrices included in this document, and that the support policy statement described earlier in this document is applied to each solution • Level 2 support is provided if any included component qualifies for Level 2 support for either of the array solutions • Level 3 support is provided for any other solutions

2.6 FS Series additional support statement The FS Series of products are NAS appliances that work with the various Dell Storage PS Series and SC Series products. All FS Series products are tested for interoperability with their respective back-end storage array products, and Dell will support any and all issues arising in or between these products while the products are under warranty and/or under an active ProSupport or Copilot support contract for both products.

The following sections describe general support policies for the FS Series, particularly as they relate to the results published in this document. There are additional environmental and cabling considerations that should be taken into account when building a storage solution that includes FS Series NAS appliances.

Please consult other FS Series documentation or contact your Dell account representative to ensure that all the relevant factors have been taken into consideration.

2.6.1 Switch support policy Dell tests switches for two of the three networks associated with an FS Series NAS cluster, namely the back- end iSCSI or Fibre Channel (FC) network situated between the NAS controllers and the PS Series or SC Series storage arrays. The FS76x0 Series NAS appliances connect to the PS Series SAN arrays using the industry-standard iSCSI protocol, while the FS8000 Series NAS appliances connect to the SC Series SAN arrays using either iSCSI or Fibre Channel. For proper configuration, at least one switch is required (a minimum of two switches is recommended) to interconnect these products. Direct connection of any FS Series NAS appliances and the respective arrays is not supported.

The three levels of support described previously are applicable to the FS Series switches listed in this matrix for back-end network configuration.

10 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Dell Storage support policy statement

There are two other networks associated with an FS76x0 Series cluster, namely the front-end connection to the customer’s existing client network, and the cluster or private interconnect network for communication between FS76x0 Series controllers. Both of these networks are Ethernet based.

Any Ethernet switch listed for use as a back-end switch is also valid for use as a private interconnect network switch and can be used for both back-end and private simultaneously.

2.6.2 Client OS environment support policy Although Dell tests the FS Series NAS solution in a variety of client operating system environments, this document does not provide resulting compatibility data. The statements made with respect to compatibility for the FS Series in this document are not to be construed as a guarantee of interoperability or supportability of client operating systems.

2.6.3 MD Series support policy statement The following MD Series array products have separate set of support documentation currently available on the website:

• MD34xx/38xx : http://dell.to/1Ov6cYQ • MD32xx/36xx : http://dell.to/1HOZiZP

General support is provided as follows:

• Level 1 support for iSCSI and FC for all industry-standards-based switches • Level 1 support for iSCSI software-based initiators for the supported shipping versions of the following operating systems: • Microsoft® Windows® • Red Hat® Enterprise Linux® • SUSE® Linux Enterprise Server • VMware® ESX®/ESXi™ • Level 1 support for all standards-based Ethernet NICs for use with the above iSCSI software-based initiators, including those that support TCP-offload functionality • Level 1 support for all RFC 3720 compliant iSCSI hardware-based initiators/HBAs • Level 1 support for Brocade®, QLogic®, and Emulex® Fibre Channel HBAs as listed in section 18 of the support matrix documents listed previously in this section.

All other devices and software not currently listed previously or in the linked support matrix documents would be supported on a Level 3 (commercially reasonable effort) basis.

2.7 Other statements

2.7.1 Operating system, switch, and server adapter settings Although this document does not cover recommended practices, optimized SAN or NAS solutions consisting of supported hardware and software (as defined in this document) are based on recommended practices documented in Dell white papers. These documents are downloadable from Dell Support and are frequently updated with recommended practices and recommended settings for various operating systems, switches, and server adapters.

11 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Dell Storage support policy statement

2.7.2 Server interoperability This compatibility matrix details interoperability from the storage array to various server hosts through a switched network and one or more network Adapters or host bus Adapters (HBAs). Testing of, and support for, a specific server platform (such as Dell PowerEdge™ servers) was not performed as part of this program and customers should visit the server vendor’s website to determine which operating systems and Adapters are supported by the server vendor.

2.7.3 Host connectivity adapters and server vendor support This matrix lists many host network Adapters and HBAs that have been tested for use within the indicated Dell Storage array family SAN environment. It is not implied that all of these Adapters and their driver/firmware stacks are supported by any or all server vendors. The reader must ensure that the host network Adapter and its associated drivers are included on the vendor's hardware compatibility list. This recommendation also applies to Dell PowerEdge server products. Inclusion in this document's adapter compatibility tables should not be interpreted as that adapter and driver/firmware combination as being supported by any vendor’s for use with their server products.

2.7.4 Persistent FCIDs With HP-UX 11i v1 and v2, it is recommended to operate Storage Center in Legacy port mode in concurrence with the use of Persistent FCID (Cisco) or Persistent PID (Brocade FOS v6.0.4 or newer & 8GB only) switches (switch-wide or per VSAN accordingly to vendor specifications).

With HP-UX 11i v3 (Agile Addressing/Naming), the Storage Center can be operated in either Legacy or Virtual port modes. The use of Persistent FCID or Persistent PID is not required for use with HP-UX 11i v3.

Additional information regarding switch level port persistency can be obtained from published Copilot Services Technical Alerts (CSTAs) located on Knowledge Center at the Dell SC Customer Portal.

The Dell Storage Software Suite for AIX v2.2.0.x introduces new features, enhancements and remove the need of certain legacy requirements. These new features and enhancements are as noted below. This will be the only package made available by Dell to customers requesting this driver package and will replace the existing PCM v1.2.0.1 (and v1.0.0.5) currently in use.

• Supports AIX v6.1 thru v7.1 • Supports use of Storage Center in Virtual port mode • Negates the need of use of Persistent FCID/PID-enabled switches • Enhanced hdisk lscfg details • Allows AIX OS to survive Storage Center controller failover events of up to 60 seconds

2.7.5 Limits of supportability If any recommendations made by Dell to resolve customer issues — whether they are functional or performance related — are not followed, Dell cannot guarantee that the issue can be resolved to the satisfaction of the customer. The ability of Dell to provide customer support is dependent on the customer’s willingness to implement solution recommendations from Dell.

12 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Switches (SC, SCv, and FS Series)

3 Switches

3.1 Fibre Channel Switches (SC, SCv, and FS Series) Fibre Channel switches listed in this section are supported at Level 1 (as described previously) for the listed switch firmware versions. Switches listed in this table are supported with Storage Center OS (SCOS) and FluidFS. Unless specifically stated in the notes column, SCOS 6.6 or later is required.

Switches listed below, with a “Switch Type” of “Converged” are also supported for use with FCoE servers as listed in the Fibre Channel over Ethernet (FCoE) Adapter section.

Fibre Channel zoning requirements, as shown in Appendix B, Fibre Channel Zoning, must be observed in order to maintain IO during Storage Center controller failovers and network/fabric path failovers.

OEM Switch Model Connectrix Switch Switch Type Switch Switch Notes Model Firmware Brocade 300 DS-300B FC 7.3.x Brocade 300 DS-300B FC 7.4.x Brocade 6505, 6510, DS-6505B, DS-6510B, FC 7.4.x 6520 DS-6520B Brocade 6505, 6510, DS-6505B, DS-6510B, FC 8.1.x SCOS 7.2.x or later 6520 DS-6520B Brocade 6505, 6510, DS-6505B, DS-6510B, FC 8.2.x SCOS 7.2.x or later 6520 DS-6520B Brocade DCX-8510-4 ED-DCX8510-4B FC 7.3.x Brocade DCX-8510-4 ED-DCX8510-4B FC 7.4.x Brocade G610, G620, DS-6610B, DS-6620B, FC 8.0.x SCOS 7.1.x or later G630, X6 DS-6630B, ED-DCX6 Brocade G610, G620, DS-6610B, DS-6620B, FC 8.1.x SCOS 7.2.x or later G630, X6 DS-6630B, ED-DCX6 Brocade G610, G620, DS-6610B, DS-6620B, FC 8.2.x SCOS 7.2.x or later G630, X6 DS-6630B, ED-DCX6 Cisco MDS 91xxS family MDS 91xxS family FC 8.2(x) SCOS 7.2.x or later Cisco MDS 92xx family MDS 92xx family FC 6.2(x) Cisco MDS family MDS 91xx family FC 6.2(x) Cisco MDS family MDS 91xx family FC 8.2.x SCOS 7.2.x or later Cisco Nexus 55xxUP - Converged 7.2(x) SCOS 6.7.x or later family Cisco Nexus 55xxUP - Converged 7.3(x) family Cisco UCS 6324 FI - Converged 3.0(x) Cisco UCS 6324 FI - Converged 3.1(x) Dell FN2210S - Converged 9.9(x) Dell M6505 - FC 7.4.x Dell M6505 - FC 8.1.x SCOS 7.2.x or later Dell MX9116n - Converged 10.4(x) SCOS 7.2.x or later; 16Gb FC Direct Connect Only Dell MXG610s - FC 8.1.0_lnx2 SCOS 7.3.x or later Dell MXL Blade - Converged 9.8(x) Dell MXL Blade - Converged 9.9(x)

13 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre channel over Ethernet Switches (SC Series)

Dell S4148U - Converged 10.4(x) SCOS 7.2.x or later

3.2 Fibre channel over Ethernet Switches (SC Series) Fibre Channel over Ethernet (FCoE) switches listed in this section are supported at Level 1 (as described previously) for the listed switch firmware versions. Switches listed in this table are supported with any Storage Center OS (SCOS) 5.5.x or later.

Switches listed in the Fibre Channel Switches section, with a “Switch Type” of “Converged” are also supported for use with FCoE servers as listed in the Fibre Channel over Ethernet (FCoE) Adapter section.

OEM Switch Model Switch Type Switch Firmware Switch Notes Cisco Nexus 55xxUP family Converged 7.2(x) SCOS 6.7.x or later Cisco Nexus 55xxUP family Converged 7.3(x) Dell M8428-k Ethernet v6.4.x

14 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM 1/10 iSCSI Switches (SC, SCv, and FS Series)

3.3 iSCSI Switches

3.3.1 1/10 iSCSI Switches (SC, SCv, and FS Series) Dell supports the use of a 1/10Gb Ethernet switch for use within SC Series iSCSI SAN solutions which meets a minimum set of criteria that Dell has determined are necessary to ensure the proper functionality of the SAN solution.

Note: For FluidFS, the iSCSI SAN switch may also be used for Interconnect (in multi-appliance configurations) and so Jumbo Frames should be supported independently of storage array.

Dell ProSupport service offerings will provide customers contractual support (Level 1 support) for iSCSI SAN based connectivity in a dedicated SAN infrastructure using any Ethernet switch that provide the following functionality and features:

• All switching components in the SAN must have active support contracts in place with device vendor • Non-blocking backplane • Link level flow control (IEEE 802.3x) on ingress/inbound switch ports (also known as “Rx Flow Control” or “receive-side flow control” from the switch port’s point of view) • Dynamic packet buffer management with a minimum of: • 4MB of packet buffer for 1Gbps switches • 9MB of packet buffer for 10Gbps switches • Ability to configure ports to immediate forwarding state for edge ports (may be known as “portfast” mode) • Jumbo Frames (MTU 9000+ bytes) support if enabled on storage array • Unicast storm control configuration • VLAN and VLAN Tagging support • Switch has a valid support contract in effect from the switch vendor at the time of the incident Protocols and standards requirements: • IEEE 802.1 AB LLDP • IEEE 802.1p L2 Prioritization • IEEE 802.1X Network Access Control • IEEE 802.3x Flow Control • IEEE 802.3z Gigabit Ethernet (1000Base-X) with QSA • IEEE 802.1Q VLAN Tagging, Double VLAN Tagging, GVRP if enabled on storage array • IEEE 802.3ac Frame Extensions for VLAN Tagging • IETF RFC793 TCP • IETF RFC1042 Ethernet Transmission

These features are typically present in certain classes of switches from switch vendors that are targeted at data center environments. These switches may be described by switch vendors as “enterprise class”, “top of rack” or “data center edge” offerings.

Please work with your Dell storage expert to determine whether your switch is suitable for use with an iSCSI SAN solution.

15 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM 25/100Gb iSCSI Switches (SC, SCv Series)

3.3.2 25/100Gb iSCSI Switches (SC, SCv Series) 25Gb and 100Gb iSCSI switches listed in this section are supported at Level 1 (as described previously) for the listed switch firmware versions.

Note: With 25Gb, disable auto-negotiation with the copper break-out cables.

Switch OEM Switch Model Protocol Switch Type Firmware Switch Notes Dell MX9116n iSCSI Converged 10.4(x) SCOS 7.2.x or later Dell MX5108n iSCSI Converged 10.4(x) SCOS 7.2.x or later Dell S4148U-ON iSCSI Converged 10.4(x) SCOS 7.2.x or later Dell S4148x-ON iSCSI Ethernet 10.4(x) SCOS 7.2.x or later Dell S4112x-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later Dell S4128x-ON iSCSI Ethernet 10.5(x) SCOS 7.3.x or later Dell S4248x-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later Dell S5212F-ON iSCSI Converged 10.4(x) SCOS 7.3.x or later Dell S5212F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later Dell S5224F-ON iSCSI Converged 10.4(x) SCOS 7.3.x or later Dell S5224F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later Dell S5232F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later Dell S5248F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later Dell S5296F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later Dell Z9264F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later Dell Z9332F-ON iSCSI Converged 10.5(x) SCOS 7.3.x or later Dell Z9100-ON iSCSI Converged 9.13(x) SCOS 7.3.x or later

16 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM 1/10Gb Switches (PS Series)

3.3.3 1/10Gb Switches (PS Series) For PS Series arrays, switches listed in this section are supported at Level 1 (as described previously) for the switch firmware versions listed and PS Series array operating system versions.

Note: Attaching 10GbE arrays to switches that are designed and provide predominately 1GbE ports (1GbE switches) is not supported due to the potential of performance limitations that could result in data- unavailable scenarios. By design, 1GbE switches typically do not have the resources to manage 10GbE edge traffic.

Note: PS6210/6610 and PS4210 can be attached to 1GbE switches via the switch’s 1GbE RJ-45 ports. In this mode, the array will operate at 1Gb only.

Vendor Model Type Switch FW PS OS Switch Interconnect Version vPC/VLT Stacking LA G Arista 7050S Eth 4.17.0F 9.0.x N/A N/A L1 Arista 7280SR Eth 4.16.7FX-7500R 9.0.x N/A N/A L1 Brocade RX Eth 2.7x 5.0.2 N/A N/A L1 Brocade RX Eth 2.8.x 6.0.x N/A N/A L1 Brocade TurboIron 24X Eth 4.2.x 4.3.x N/A N/A L1 Brocade TurboIron 24X Eth 7.3.x L2 N/A N/A L2 Brocade VDX 6720 Conv 2.0.x 5.1.x N/A L3 L1 Brocade VDX 6720 Conv 5.0.x 7.0.x N/A L3 L1 Brocade VDX 6940 Conv 7.0.1 9.0.x N/A L3 L1 Cisco Catalyst 3750X-48T-L Eth 12.x 5.1.x N/A L1 L1 Cisco Catalyst 3750X-48T-L Eth 6.0.x N/A L1 L1 Cisco Catalyst 3750X-48T-L Eth 7.0.x N/A L1 L1 Cisco Catalyst 3750X-48T-L Eth 8.0.x N/A L1 L1 Cisco Catalyst 3850 Family Eth 3.07.04E 8.0.x N/A L1 L1 Cisco Catalyst 4948-10G Eth 12.2.x 4.3.x N/A N/A L1 Cisco Catalyst 4948-10G Eth 15.0.x 7.0.x N/A N/A L1 Cisco Catalyst 4948-10G Eth 8.0.x N/A L1 L1 Cisco Catalyst 4948-10G Eth 8.1.x N/A L1 L1 Cisco Catalyst 4948-10G Eth 9.0.x N/A N/A L1 Cisco Catalyst 4948E Eth 15.2.x 7.0.x N/A N/A L1 Cisco Catalyst 4948E Eth 15.2.x 8.1.x N/A N/A L1 Cisco Catalyst 4948E Eth 9.0.x N/A N/A L1

17 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM 1/10Gb Switches (PS Series)

Vendor Model Type Switch FW PS OS Switch Interconnect Version vPC/VLT Stacking LA G Cisco Nexus 55xxUP Conv 5.2.x 6.0.x L1 N/A L1 Cisco Nexus 55xxUP Conv 6.0.x 6.0.x L1 N/A L1 Cisco Nexus 55xxUP Conv 7.0.x 7.0.x L1 N/A L1 Cisco Nexus 55xxUP Conv 8.0.x L1 L1 L1 Cisco Nexus 55xxUP Conv 7.1.x 8.1.x L1 N/A L1 Cisco Nexus 55xxUP Conv 7.2.x 9.0.x L1 N/A L1 Cisco Nexus 5648Q (no DCB) Eth 7.3(2)N1(1) 9.1 L1 NA L1 Cisco Nexus 6000 Family Conv 7.0.x 7.0.x L1 N/A L1 Cisco Nexus 6000 Family Conv 7.0.x 7.1.x L1 N/A L1 Cisco Nexus 6000 Family Conv 7.1.x 8.1.x L1 N/A L1 Cisco Nexus 6000 Family Conv 7.2.x 9.0.x L1 N/A L1 Cisco Nexus 7000 Family Conv 6.1.x 6.0.x L3 N/A L1 Cisco Nexus 7000 Family Conv 6.2.x 7.0.x L3 N/A L1 Cisco Nexus 7000 Family Conv 8.0.x N/A N/A L1 Cisco Nexus 7000 Family Conv 8.1.x N/A N/A L1 Cisco Nexus 7000 Family Conv 9.0.x L1 N/A L1 Cisco Nexus 9372PX (no DCB) Eth 7.0(3) I5(2) 9.1 L1 NA L1 Cisco Nexus 9500 Conv 7.0(3) 7.1.x L1 N/A L1 Cisco Nexus 9500 Conv 9.0.x L1 N/A L1 Dell Dell Networking N2000 Eth 6.0.x 7.0.x N/A L1 L1 Dell Dell Networking N2000 Eth 8.0.x N/A L1 L1 Dell Dell Networking N2000 Eth 6.2.x 8.1.x N/A L1 L1 Dell Dell Networking N2000 Eth 9.0.x L3 L1 L1 Dell Dell Networking N3000 Eth 6.0.x 7.0.x N/A L1 L1 Dell Dell Networking N3000 Eth 8.0.x N/A L1 L1 Dell Dell Networking N3000 Eth 6.2.x 8.1.x N/A L1 L1 Dell Dell Networking N3000 Eth 9.0.x L3 L1 L1 Dell Dell Networking N4000 Eth 6.0.x 7.0.x N/A L1 L1 Dell Dell Networking N4000 Eth 6.1.x 7.1.x N/A L1 L1 Dell Dell Networking N4000 Eth 6.1.x 8.0.x N/A L1 L1 Dell Dell Networking N4000 Eth 6.2.x 8.1.x N/A L1 L1

18 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM 1/10Gb Switches (PS Series)

Vendor Model Type Switch FW PS OS Switch Interconnect Version vPC/VLT Stacking LA G Dell Dell Networking N4000 Eth 9.0.x L3 L1 L1 Dell Dell Networking S3000- ON Eth 9.8.x 7.1.x N/A L1 L1 Dell Dell Networking S3000- ON Eth 9.9.x 8.1.x L1 L1 L1 Dell Dell Networking S3000- ON Eth 9.0.x L1 L1 L1 Dell Dell Networking S3000- ON Eth 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking S3000- ON Eth 10.3.1 9.0.x L1 L1 L1 Dell Dell Networking S3100 Eth 9.8.x 9.0.x L1 L1 L1 Dell Dell Networking S4000- ON Eth 9.8.x 7.1.x L1 L1 L1 Dell Dell Networking S4000- ON Eth 9.9.x 8.1.x L1 L1 L1 Dell Dell Networking S4000- ON Eth 9.0.x L1 L1 L1 Dell Dell Networking S4000- ON Eth 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking S4000- ON Eth 10.3.1 9.1.x L1 L1 L1 Dell Dell Networking S4128F Conv 10.3.1E 9.1 L1 NA L1 Dell Dell Networking S4148F Conv 10.3.1E 9.1 L1 NA L1 Dell Dell Networking S4148T Conv 10.3.1E 9.1 L1 NA L1 Dell Dell Networking S4148U Conv 10.3.1E 9.1 L1 NA L1 Dell Dell Networking S4148FE Conv 10.3.1E 9.1 L1 NA L1 Dell Dell Networking S4248FB Conv 10.4.0E(R2) 9.1 L1 NA L1 Dell Dell Networking S4248FBL Conv 10.4.0E(R2) 9.1 L1 NA L1 Dell Dell Networking S5000 Conv 9.0.x 6.0.x L1 L1 L1 Dell Dell Networking S5000 Conv 7.0.x L1 L1 L1 Dell Dell Networking S5000 Conv 9.1.x 7.0.x L1 L1 L1 Dell Dell Networking S5000 Conv 8.0.x L1 L1 L1 Dell Dell Networking S5000 Conv 9.6.x 7.0.x L1 L1 L1 Dell Dell Networking S5000 Conv 9.7.x 8.0.x L1 L1 L1 Dell Dell Networking S5000 Conv 9.8.x 7.1.x L1 L1 L1 Dell Dell Networking S5000 Conv 9.9.x 8.1.x L1 L1 L1 Dell Dell Networking S5000 Conv 9.0.x L1 L1 L1 Dell Dell Networking S5000 Conv 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking S6000 Eth 9.0.x 6.0.x L1 L1 L1 Dell Dell Networking S6000 Eth 9.3.x 7.0.x L1 L1 L1

19 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM 1/10Gb Switches (PS Series)

Vendor Model Type Switch FW PS OS Switch Interconnect Version vPC/VLT Stacking LA G Dell Dell Networking S6000 Eth 9.4.x 7.0.x L1 L1 L1 Dell Dell Networking S6000 Eth 9.6.x 7.0.x L1 L1 L1 Dell Dell Networking S6000 Eth 8.0.x L1 L1 L1 Dell Dell Networking S6000 Eth 9.7.x 7.1.x L1 L1 L1 Dell Dell Networking S6000 Eth 9.8.x 7.1.x L1 L1 L1 Dell Dell Networking S6000 Eth 9.9.x 8.1.x L1 L1 L1 Dell Dell Networking S6000 Eth 9.0.x L1 L1 L1 Dell Dell Networking S6000 Eth 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking S6010 Eth 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking Z9000 Eth 9.3.x 7.0.x L1 L1 L1 Dell Dell Networking Z9000 Eth 9.4.x 7.0.x L1 L1 L1 Dell Dell Networking Z9000 Eth 9.7.x 7.1.x L1 L1 L1 Dell Dell Networking Z9000 Eth 9.8.x 7.1.x L1 L1 L1 Dell Dell Networking Z9000 Eth 9.9.x 8.1.x L1 L1 L1 Dell Dell Networking Z9000 Eth 9.0.x L1 L1 L1 Dell Dell Networking Z9000 Eth 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking Z9500 Eth 9.5.x 7.0.x L1 L1 L1 Dell Dell Networking Z9500 Eth 9.7.x 7.1.x L1 L1 L1 Dell Dell Networking Z9500 Eth 8.0.x L1 L1 L1 Dell Dell Networking Z9500 Eth 9.0.x L1 L1 L1 Dell Dell Networking Z9500 Eth 9.8.x 7.1.x L1 L1 L1 Dell Dell Networking Z9500 Eth 9.9.x 8.1.x L1 L1 L1 Dell Dell Networking Z9500 Eth 9.0.x L1 L1 L1 Dell Dell Networking Z9500 Eth 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking C-7000 Eth 7.7.x 4.3.x N/A N/A L1 Dell Dell Networking C-9000 Eth 9.9.x 8.1.x L3 N/A L1 Dell Dell Networking C-9000 Eth 9.0.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 8.3.x 5.2.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 6.0.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 9.2.x 6.0.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 7.0.x L1 L1 L1

20 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM 1/10Gb Switches (PS Series)

Vendor Model Type Switch FW PS OS Switch Interconnect Version vPC/VLT Stacking LA G Dell Dell Networking MXL/IOA Eth 9.4.x 7.0.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 9.6.x 7.0.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 8.0.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 9.7.x 7.1.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 9.8.x 7.1.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 9.9.x 8.1.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 9.0.x L1 L1 L1 Dell Dell Networking MXL/IOA Eth 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking S4810 Eth 8.3.x 5.1.x N/A L1 L1 Dell Dell Networking S4810 Eth 8.3.x 5.2.x N/A L1 L1 Dell Dell Networking S4810 Eth 6.0.x N/A L1 L1 Dell Dell Networking S4810 Eth 9.1.x 6.0.x L1 L1 L1 Dell Dell Networking S4810 Eth 9.2.x 7.0.x L1 L1 L1 Dell Dell Networking S4810 Eth 9.4.x 7.0.x L1 L1 L1 Dell Dell Networking S4810 Eth 9.5.x 8.0.x L1 L1 L1 Dell Dell Networking S4810 Eth 9.6.x 7.0.x L1 L1 L1 Dell Dell Networking S4810 Eth 7.1.x L1 L1 L1 Dell Dell Networking S4810 Eth 9.7.x 7.1.x L1 L1 L1 Dell Dell Networking S4810 Eth 9.8.x 7.1.x L1 L1 L1 Dell Dell Networking S4810 Eth 9.9.x 8.1.x L1 L1 L1 Dell Dell Networking S4810 Eth 9.0.x L1 L1 L1 Dell Dell Networking S4810 Eth 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking S4820T Eth 8.3.x 6.0.x L1 L1 L1 Dell Dell Networking S4820T Eth 9.2.x 7.0.x L1 L1 L1 Dell Dell Networking S4820T Eth 8.0.x L1 L1 L1 Dell Dell Networking S4820T Eth 9.4.x 7.0.x L1 L1 L1 Dell Dell Networking S4820T Eth 9.6.x 7.0.x L1 L1 L1 Dell Dell Networking S4820T Eth 9.7.x 7.1.x L1 L1 L1 Dell Dell Networking S4820T Eth 9.8.x 7.1.x L1 L1 L1 Dell Dell Networking S4820T Eth 9.9.x 8.1.x L1 L1 L1 Dell Dell Networking S4820T Eth 9.0.x L1 L1 L1

21 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM 1/10Gb Switches (PS Series)

Vendor Model Type Switch FW PS OS Switch Interconnect Version vPC/VLT Stacking LA G Dell Dell Networking S4820T Eth 9.10.x 9.0.x L1 L1 L1 Dell Dell Networking S25N/S50N Eth 7.7.x 4.3.x N/A L1 L1 Dell Dell Networking S25N/S50N Eth 8.4.x 5.1.x N/A L1 L1 Dell Dell Networking S25N/S50N Eth 6.0.x N/A L1 L1 Dell Dell Networking S25N/S50N Eth 7.0.x N/A L1 L1 Dell Dell Networking S55 Eth 8.3.x 5.1.x N/A L1 L1 Dell Dell Networking S55 Eth 6.0.x N/A L1 L1 Dell Dell Networking S55 Eth 7.0.x N/A L1 L1 Dell Dell Networking S55 Eth 8.0.x N/A L1 L1 Dell Dell Networking S55 Eth 9.0.x L1 L1 L1 Dell Dell Networking S60 Eth 8.3.x 5.1.x N/A L1 L1 Dell Dell Networking S60 Eth 6.0.x N/A L1 L1 Dell Dell Networking S60 Eth 7.0.x N/A L1 L1 Dell Dell Networking S60 Eth 8.0.x N/A L1 L1 Dell Dell Networking S60 Eth 8.3.x 8.1.x N/A L1 L1 Dell Dell Networking S60 Eth 9.0.x L1 L1 L1 Dell PowerConnect 70xx Family Eth 4.1.x 4.3.x N/A L1 L1 Dell PowerConnect 70xx Family Eth 4.2.x 6.0.x N/A L1 L1 Dell PowerConnect 70xx Family Eth 5.0.x 6.0.x N/A L1 L1 Dell PowerConnect 70xx Family Eth 5.1.x 6.0.x N/A L1 L1 Dell PowerConnect 70xx Family Eth 7.0.x N/A L1 L1 Dell PowerConnect 70xx Family Eth 9.0.x N/A L1 L1 Dell PowerConnect 81xx Family Eth 5.0.x 5.2.x N/A L1 L1 Dell PowerConnect 81xx Family Eth 6.0.x N/A L1 L1 Dell PowerConnect 81xx Family Eth 5.1.x 6.0.x N/A L1 L1 Dell PowerConnect 81xx Family Eth 7.0.x N/A L1 L1 Dell PowerConnect 81xx Family Eth 6.0.x 7.0.x N/A L1 L1 Dell PowerConnect M6348 Eth 3.1.x 4.3.x N/A L1 L1 Dell PowerConnect M6348 Eth 4.2.x 6.0.x N/A L1 L1 Dell PowerConnect M6348 Eth 5.0.x 6.0.x N/A L1 L1 Dell PowerConnect M6348 Eth 5.1.x 6.0.x N/A L1 L1

22 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM 1/10Gb Switches (PS Series)

Vendor Model Type Switch FW PS OS Switch Interconnect Version vPC/VLT Stacking LA G Dell PowerConnect M6348 Eth 7.0.x N/A L1 L1 Dell PowerConnect M6348 Eth 8.0.x N/A L1 L1 Dell PowerConnect M8428-k Eth 6.3.x 6.0.x N/A L3 L1 Dell PowerConnect M8428-k Eth 7.0.x N/A L3 L1 Dell PowerConnect M8428-k Eth 8.0.x N/A L1 L1 Dell PowerEdge IO Aggregator Eth 8.3.x 6.0.x N/A L1 L1 Dell PowerEdge IO Aggregator Eth 9.2.x 6.0.x L1 L1 L1 Dell PowerEdge IO Aggregator Eth 7.0.x L1 L1 L1 Dell PowerEdge IO Aggregator Eth 9.6.x 7.0.x L1 L1 L1 Dell PowerEdge IO Aggregator Eth 8.0.x L1 L1 L1 CE6850 Eth 8.100 9.1.x L1 NA L1 HP 5900AF-48G Eth 7.1.x 7.0.x N/A L3 L1 HP 5900AF-48G Eth 8.0.x N/A L1 L1

23 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI over DCB support (SC, SCv and PS Series)

3.4 iSCSI over DCB support (SC, SCv and PS Series) The following table indicates switches that have been tested with each array family’s native iSCSI over DCB features.

SC Series arrays, with the release of SC Operating System (SCOS) 7.0 now support iSCSI over DCB. With this support, the SC series supports the following DCB standards:

• IEEE 802.1Qbb – Priority Flow Control • IEEE 802.1Qaz – Enhanced Transmission Selection • IEEE 802.1Qaz – Exchange Protocol (IEEE DCBx)

Note: SC Series arrays do not support pre-IEEE DCBx standards such as converged enhanced Ethernet (CEE) or data center Ethernet (DCE) for iSCSI over DCB functionality. Switches that are listed in the table below that only support these pre-IEEE versions are designated as “L4” indicating there is “No Support”.

Note: SC Series iSCSI over DCB is supported on controllers using the Chelsio T5xxx iSCSI Adapters at this time.

Vendor Model Type Switch FW PS SC Notes Version OS OS Cisco Nexus 55xxUP Conv 7.0.x 7.0. L4 Cisco Nexus switches only x support CEE version of DCBx and are not compatible with SC Series Cisco Nexus 55xxUP 8.0. L4 Array iSCSI over DCB x functionality Cisco Nexus 55xxUP 7.1.x 8.1. L4 x Cisco Nexus 6000 Family Conv 7.0.x 7.0. L4 x Cisco Nexus 6000 Family 7.1. L4 x Cisco Nexus 6000 Family 7.1.x 8.1. L4 x Dell Dell Networking N4000 Eth 6.0.x 7.0. L4 Switches based on DNOS 6.x x prior to 6.3.0.3 only support CEE version Dell Dell Networking N4000 6.1.x 7.1. L4 of DCBx and are not compatible x with SC Series Array iSCSI over Dell Dell Networking N4000 8.0. L4 DCB functionality x Dell Dell Networking N4000 6.2.x 8.1. L4 x Dell Dell Networking N4000 6.3.x 8.0. 7.0.x SC DCB support requires DNOS x 6.3.0.3 or later Dell Dell Networking S4000-ON Eth 9.8.x 7.1. L3 x

24 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI over DCB support (SC, SCv and PS Series)

Vendor Model Type Switch FW PS SC Notes Version OS OS Dell Dell Networking S4000-ON 9.9.x 8.1. 7.0.x x Dell Dell Networking S4000-ON 9.10.x 8.1. 7.0.x x Dell Dell Networking S4000-ON Conv 10.3.1 9.1 7.2.1 Dell Dell Networking S4128F Conv 10.3.1E 9.1 7.2.1 Dell Dell Networking S4148F Conv 10.3.1E 9.1 7.2.1 Dell Dell Networking S4128T Conv 10.3.1E 9.1 7.2.1 Dell Dell Networking S4148T Conv 10.3.1E 9.1 7.2.1 Dell Dell Networking S4148U Conv 10.3.1E 9.1 7.2.1 Dell Dell Networking S4148FE Conv 10.3.1E 9.1 7.2.1 Dell Dell Networking S4248FB Conv 10.4.0E(R2) 9.1 7.2.1 Dell Dell Networking S4248FBL Conv 10.4.0E(R2) 9.1 7.2.1 Dell DN S5000 Conv 9.0.x 6.0. L3 x Dell DN S5000 7.0. L3 x Dell DN S5000 Conv 9.1.x 7.0. L3 x Dell DN S5000 9.1.x 8.0. L3 x Dell DN S5000 9.6.x 7.0. L3 x Dell DN S5000 9.7.x 8.0. L3 x Dell DN S5000 9.8.x 7.1. L3 x Dell DN S5000 9.9.x 8.1. 7.0.x x Dell DN S5000 9.10.x 8.1. 7.0.x x Dell Dell Networking S5048F Conv 9.12.1 9.1 7.2.1 LLFC is not supported. Only Dell Dell Networking S5048F Conv 9.12.1 9.1 7.2.1 LLFC is not supported. Only Dell Dell Networking S6000 Eth 9.0.x 6.0. L3 x

25 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI over DCB support (SC, SCv and PS Series)

Vendor Model Type Switch FW PS SC Notes Version OS OS Dell Dell Networking S6000 9.3.x 7.0. L3 x Dell Dell Networking S6000 9.4.x 7.0. L3 x Dell Dell Networking S6000 9.6.x 7.0. L3 x Dell Dell Networking S6000 8.0. L3 x Dell Dell Networking S6000 9.7.x 7.1. L3 x Dell Dell Networking S6000 9.8.x 7.1. L3 x Dell Dell Networking S6000 9.9.x 8.1. 7.0.x x Dell Dell Networking S6000 9.10.x 8.1. 7.0.x x Dell Dell Networking S6100 Conv 9.10.x 8.1. 7.0.x x Dell Dell Networking Z9000 Eth 9.7.x 7.1. L3 x Dell Dell Networking Z9000 9.8.x 7.1. L3 x Dell Dell Networking Z9000 9.9.x 8.1. 7.0.x x Dell Dell Networking Z9000 9.10.x 8.1. 7.0.x x Dell Z9100 Conv 9.10.x 8.1. 7.0.x x Dell Dell Networking Z9500 Eth 9.7.x 7.1. L3 x Dell Dell Networking Z9500 8.0. L3 x Dell Dell Networking Z9500 9.8.x 7.1. L3 x Dell Dell Networking Z9500 9.9.x 8.1. 7.0.x x Dell Dell Networking Z9500 9.10.x 8.1. 7.0.x x Dell Dell Networking C-9000 Eth 9.9.x 8.1. 7.0.x All SAN ports must be 10GbE and x DCB enabled Dell Dell Networking C-9000 9.10.x 8.1. 7.0.x x Dell Dell Networking MXL/IOA Eth 9.2.x 6.0. L3 x Dell Dell Networking MXL/IOA 7.0. L3 x Dell Dell Networking MXL/IOA 9.4.x 7.0. L3 x Dell Dell Networking MXL/IOA 9.6.x 7.0. L3 x Dell Dell Networking MXL/IOA 8.0. L3 x Dell Dell Networking MXL/IOA 9.7.x 7.1. L3 x Dell Dell Networking MXL/IOA 9.8.x 7.1. L3 x

26 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI over DCB support (SC, SCv and PS Series)

Vendor Model Type Switch FW PS SC Notes Version OS OS Dell Dell Networking MXL/IOA 9.9.x 8.1. 7.0.x x Dell Dell Networking MXL/IOA 9.10.x 8.1. 7.0.x x Dell Dell Networking S4810 Eth 8.3.x 5.2. L3 x Dell Dell Networking S4810 6.0. L3 x Dell Dell Networking S4810 9.1.x 6.0. L3 x Dell Dell Networking S4810 9.2.x 7.0. L3 x Dell Dell Networking S4810 9.4.x 7.0. L3 x Dell Dell Networking S4810 9.5.x 8.0. L3 x Dell Dell Networking S4810 9.6.x 7.0. L3 x Dell Dell Networking S4810 7.1. L3 x Dell Dell Networking S4810 9.7.x 7.1. L3 x Dell Dell Networking S4810 9.8.x 7.1. L3 x Dell Dell Networking S4810 9.9.x 8.1. 7.0.x x Dell Dell Networking S4810 9.10.x 8.1. 7.0.x x Dell Dell Networking S4820T Eth 8.3.x 6.0. L3 x Dell Dell Networking S4820T 9.2.x 7.0. L3 x Dell Dell Networking S4820T 8.0. L3 x Dell Dell Networking S4820T 9.4.x 7.0. L3 x Dell Dell Networking S4820T 9.6.x 7.0. L3 x Dell Dell Networking S4820T 9.7.x 7.1. L3 x Dell Dell Networking S4820T 9.8.x 7.1. L3 x

27 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI over DCB support (SC, SCv and PS Series)

Vendor Model Type Switch FW PS SC Notes Version OS OS Dell Dell Networking S4820T 9.9.x 8.1. 7.0.x x Dell Dell Networking S4820T 9.10.x 8.1. 7.0.x x Dell PowerConnect 81xx Family Eth 5.0.x 5.2. L4 Switches based on DNOS 6.x x prior to 6.3.0.3 only support CEE version Dell PowerConnect 81xx Family 6.0. L4 of DCBx and are not compatible x with SC Dell PowerConnect 81xx Family 5.1.x 6.0. L4 Series Array iSCSI over DCB x functionality Dell PowerConnect 81xx Family 7.0. L4 x Dell PowerConnect 81xx Family 6.0.x 7.0. L4 PowerConnect 81xx switches with x DNOS 6.x or later are considered Dell Networking N4000 switches Dell PowerEdge IO Aggregator Eth 9.2.x 6.0. L3 x Dell PowerEdge IO Aggregator 7.0. L3 x Dell PowerEdge IO Aggregator 9.6.x 7.0. L3 x Dell PowerEdge IO Aggregator 8.0. L3 x Dell PowerEdge IO Aggregator 9.7.x 7.1. L3 x Dell PowerEdge IO Aggregator 9.8.x 7.1. L3 x Dell PowerEdge IO Aggregator 9.9.x 8.1. 7.0.x x Dell PowerEdge IO Aggregator 9.10.x 8.1. 7.0.x x

28 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Host connectivity

4 Host connectivity Configurations listed in this section are supported at Level 1 for the listed Adapter/NIC operating system/driver/firmware and array firmware combinations.

The model SCv2000, SCv2020, and SCv2080 only support a subset of host operating systems. These are:

• Citrix XenServer (now known as Hypervisor), • Microsoft Windows Server, • SUSE SLES • RHEL • VMware ESXi

All other supported Storage Center models support all OS’s and adapters listed in the following table.

Boot from SAN is tested with some OS-adapter combinations. If the BFS column has a “Y”, then Boot from SAN was successfully tested with this OS-Adapter combination. If the BFS column has an “N”, then Boot from SAN was not tested and is supported as Level 3, Commercially reasonable effort as described in 2.3 above. If the BFS column has a “Not Supported”, then Boot from SAN has not been tested and is not supported, as described in section 2.4 above.

Unless otherwise noted, the OS-provided native multipath IO functionality for all validations listed.

4.1 Required Adapter and Server OS Settings Server host bus adapters and converged network adapters (hereafter called adapters) require specific configuration settings in order to maintain IO during Storage Center controller failovers and network/fabric path failovers. Some of these settings are identical for all supported operating systems and others vary by operating system. Refer to Appendix A, Required Adapter and OS Settings.

29 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

4.2 Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 6.7.x No Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 7.1.x No Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 7.2.x No Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 7.3.x No Multipath supported with SCOS 7.4.5 or Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 7.4.x No later Multipath supported with SCOS 7.4.5 or Apple Mac OS X 10.x LSI 7204EP OS Built-In - 1.3.23.0 7.5.x No later Multipath supported with SCOS 7.4.5 or Apple Mac OS X 10.x Promise SANLink 2.09 (SR3.0.8) - 1.1.65.43 7.4.x No later Multipath supported with SCOS 7.4.5 or Apple Mac OS X 10.x Promise SANLink 2.09 (SR3.0.8) - 1.1.65.43 7.5.x No later Citrix XenServer 6.5 Emulex LPe1200x/LPe1205 10.2.340.0 5.13a11 2.02A1 7.1.x Yes Citrix XenServer 6.5 Emulex LPe1200x/LPe1205 10.2.340.0 5.13a3 2.01A12 6.7.x Yes Citrix XenServer 6.5 QLogic QxE256x 8.07.00.09.66.5-k 3.27 7.04.00 6.7.x Yes Citrix XenServer 6.5 QLogic QxE256x 8.07.00.09.66.5-k 3.29 8.01.02 7.1.x Yes Citrix XenServer 7.0 Emulex LPe1200x/LPe1205 11.0.0.12 5.13a11 2.02A1 7.1.x Yes Citrix XenServer 7.0 Emulex LPe1200x/LPe1205 11.0.0.12 5.13a11 2.02A1 7.2.x Yes Citrix XenServer 7.0 Emulex LPe1200x/LPe1205 11.1.210.1 5.13a11 2.02A1 7.2.x Yes Citrix XenServer 7.0 QLogic QxE256x 8.07.00.33.77.0-k 3.29 8.01.02 7.1.x Yes Citrix XenServer 7.0 QLogic QxE256x 8.07.00.33.77.0-k 3.29 8.01.02 7.2.x Yes Citrix XenServer 7.0 QLogic QxE256x 8.07.00.41.77.1-k 3.29 8.01.02 7.2.x Yes Citrix XenServer 7.1 Emulex LPe1200x/LPe1205 11.0.0.12 5.13a11 2.02A1 7.2.x Yes

30 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Citrix XenServer 7.1 QLogic QxE256x 8.07.00.33.77.0-k 3.29 8.01.02 7.2.x Yes Citrix XenServer 7.2 Emulex LPe1200x/LPe1205 11.1.210.1 11.40a6 2.02a3 7.3.x Yes Citrix XenServer 7.2 Emulex LPe1200x/LPe1205 11.1.210.1 5.13a11 2.02A1 7.2.x Yes Citrix XenServer 7.2 QLogic QxE256x 8.07.00.41.77.1-k 3.29 8.01.02 7.2.x Yes Citrix XenServer 7.2 QLogic QxE256x 8.07.00.41.77.1-k 3.43 8.07.00 7.3.x Yes Citrix XenServer 7.6 Emulex LPe1200x/LPe1205 11.1.210.1 12.00a4 2.02A4 7.3.x Yes Citrix XenServer 7.6 Emulex LPe1200x/LPe1205 11.1.210.1 12.00a4 2.02A4 7.4.x Yes Citrix XenServer 7.6 QLogic QxE256x 8.08.00.07.71.0-k 3.43 8.08.01 7.3.x Yes Citrix XenServer 7.6 QLogic QxE256x 8.08.00.07.71.0-k 3.43 8.08.01 7.4.x Yes Citrix Hypervisor (XenServer) 8.0 Emulex LPe1200x/LPe1205 12.0.0.10 12.00a4 2.02A4 7.3.x Yes Citrix Hypervisor (XenServer) 8.0 Emulex LPe1200x/LPe1205 12.0.0.10 12.00a4 2.02A4 7.4.x Yes Citrix Hypervisor (XenServer) 8.0 QLogic QxE256x 10.00.00.11.80.0-k 3.43 8.08.01 7.3.x Yes Citrix Hypervisor (XenServer) 8.0 QLogic QxE256x 10.00.00.11.80.0-k 3.43 8.08.01 7.4.x Yes Citrix Hypervisor (XenServer) 8.2 Emulex LPe1200x/LPe1205 12.0.0.10 12.00a4 2.02A4 7.5.x Yes Citrix Hypervisor (XenServer) 8.2 QLogic QxE256x 10.01.00.54.80.0-k 3.43 8.08.01 7.5.x Yes HP HP-UX 11iv3 HP AB379A B.11.31.1705 1.05 4.00.070 7.3.x Yes HP HP-UX 11iv3 HP AB379A B.11.31.1705 1.05 4.00.070 7.4.x Yes HP HP-UX 11iv3 HP AB379A B.11.31.1705 1.05 4.00.070 7.5.x Yes HP HP-UX 11iv3 HP AD194 B.11.31.1705 1.05 4.00.070 6.7.x Yes HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 6.7.x Yes HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 7.1.x Yes HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 7.2.x Yes HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 7.3.x Yes HP HP-UX 11iv3 HP AH401A B.11.31.1009 2.22 5.03.15 7.4.x Yes HP HP-UX 11iv3 HP AH401A B.11.31.1705 2.22 5.03.15 6.7.x Yes

31 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version HP HP-UX 11iv3 HP AH401A B.11.31.1705 2.22 5.03.15 7.3.x Yes HP HP-UX 11iv3 HP AH401A B.11.31.1705 2.22 5.03.15 7.4.x Yes HP HP-UX 11iv3 HP AH401A B.11.31.1705 2.22 5.03.15 7.5.x Yes HP HP-UX 11iv3 HP AH403A B.11.31.1708 UU11.40A9 2.03X14 6.7.x Yes HP HP-UX 11iv3 HP AH403A B.11.31.1708 UU11.40A9 2.03X14 7.3.x Yes HP HP-UX 11iv3 HP AH403A B.11.31.1708 UU11.40A9 2.03X14 7.4.x Yes HP HP-UX 11iv3 HP AH403A B.11.31.1708 UU11.40A9 2.03X14 7.5.x Yes HP HP-UX 11iv3 HP AT094A B.11.31.1708 UU11.40A9 2.03X14 6.7.x Yes HP HP-UX 11iv3 HP AT094A B.11.31.1708 UU11.40A9 2.03X14 7.3.x Yes HP HP-UX 11iv3 HP AT094A B.11.31.1708 UU11.40A9 2.03X14 7.4.x Yes HP HP-UX 11iv3 HP AT094A B.11.31.1708 UU11.40A9 2.03X14 7.5.x Yes HP OpenVMS 8.4 HP AD194 2.05 - 4.04.004 7.3.x Yes HP OpenVMS 8.4 HP AD194 2.05 - 4.04.004 7.4.x Yes HP OpenVMS 8.4 HP FCA2354 2.05 - 4.04.004 6.7.x Yes HP OpenVMS 8.4 HP FCA2354 2.05 - 4.04.004 7.1.x Yes HP OpenVMS 8.4 HP FCA2354 2.05 - 4.04.004 7.2.x Yes Tested with Multipath driver IBM AIX 6.1 IBM 577D 6.1.7.0 3.10X2 2.02X7 7.1.x Yes MPAIX03.00.00.007 Tested with Multipath driver IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 6.7.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 7.1.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 7.2.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 7.3.x Yes MPAIX03.00.02.005

32 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Tested with Multipath driver IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 7.4.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 6.1 IBM 577D 6.1.9.200 3.10X2 2.02X7 7.5.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 1.1.58.4 7.2.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 1.1.58.4 7.3.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 2.02X7 6.7.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 2.02X7 7.1.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 11.2.211.21 7.3.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 11.2.211.21 7.4.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 6.1 IBM 577F 6.1.9.200 3.10X2 11.2.211.21 7.5.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.1 IBM 577D 7.1.0.22 3.10X2 2.02X7 7.1.x Yes MPAIX03.00.00.007 Tested with Multipath driver IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 6.7.x Yes MPAIX03.00.01.006

33 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Tested with Multipath driver IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 7.1.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 7.2.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 7.3.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 7.4.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.1 IBM 577D 7.1.4.30 3.10X2 2.02X7 7.5.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 1.1.58.4 7.2.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 1.1.58.4 7.3.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 2.02X7 6.7.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 2.02X7 7.1.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 11.2.211.21 7.3.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 11.2.211.21 7.4.x Yes MPAIX03.00.02.005

34 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Tested with Multipath driver IBM AIX 7.1 IBM 577F 7.1.4.30 3.10X2 11.2.211.21 7.5.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 6.7.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 7.1.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 7.2.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 7.3.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 7.4.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.2 IBM 577D 7.2.1.0 3.10X2 2.02X7 7.5.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 1.1.58.4 7.2.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 1.1.58.4 7.3.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 2.02X7 6.7.x Yes MPAIX03.00.01.006 Tested with Multipath driver IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 2.02X7 7.1.x Yes MPAIX03.00.01.006

35 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Tested with Multipath driver IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 11.2.211.21 7.3.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 11.2.211.21 7.4.x Yes MPAIX03.00.02.005 Tested with Multipath driver IBM AIX 7.2 IBM 577F 7.2.1.1 3.10X2 11.2.211.21 7.5.x Yes MPAIX03.00.02.005 Microsoft 2008 Windows Server R2 SP1 Cisco VIC-13xx 2.1.0.34 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 10.6.114.0 6.03X1 2.01A12 6.7.x Yes Dell fw kit: 01.06.01 Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 10.6.114.0 6.03X1 2.01A12 7.1.x Yes Dell fw kit: 01.06.01 Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 11.0.247.0 5.12a11 2.01A12 7.2.x Yes Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 11.0.247.0 7.00x1 2.01A12 7.1.x Yes Dell fw kit: 02.00.04 Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 11.0.247.0 7.00x1 2.01A12 7.2.x Yes Dell fw kit: 02.00.04 Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 11.0.247.0 7.00x1 2.02A1 6.7.x Yes Dell fw kit: 02.00.04 Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 11.0.247.0 7.00x1 2.02A1 7.2.x Yes Dell fw kit: 02.00.04

36 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 11.2.124.0 11.40a6 2.02a3 7.3.x Yes Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 11.2.124.0 5.12a11 2.02a3 7.2.x Yes Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 11.2.124.0 6.03X1 2.02a3 7.2.x Yes Dell fw kit: 02.01.01* Microsoft 2008 Windows Server R2 SP1 Emulex LPe1200x/LPe1205 11.2.124.0 6.03X1 2.02a3 7.3.x Yes Dell fw kit: 02.01.01* Microsoft 2008 Windows Server R2 SP1 Emulex LPx1500x/LPx1600x 10.4.246.0 10.4.255.16 10.4.255.16 6.7.x Yes Microsoft 2008 Windows Server R2 SP1 Emulex LPx1500x/LPx1600x 10.6.114.0 10.6.144.21 10.6.144.21 7.1.x Yes Microsoft 2008 Windows Server R2 SP1 Emulex LPx1500x/LPx1600x 11.0.247.0 11.1.38.61 11.1.38.61 7.1.x Yes Microsoft 2008 Windows Server R2 SP1 Emulex LPx1500x/LPx1600x 11.0.247.0 11.1.38.61 11.1.38.61 7.2.x Yes Microsoft 2008 Windows Server R2 SP1 Emulex LPx1500x/LPx1600x 11.2.124.0 11.4.142.23 11.4.142.23 7.2.x Yes Microsoft 2008 Windows Server R2 SP1 Emulex LPx1500x/LPx1600x 11.2.124.0 11.4.142.23 11.4.142.23 7.3.x Yes Microsoft 2008 Windows Server R2 SP1 QLogic QxE256x 9.1.13.20 3.27 7.04.00 6.7.x Yes

37 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2008 Windows Server R2 SP1 QLogic QxE256x 9.1.15.21 3.29 8.01.02 7.1.x Yes Microsoft 2008 Windows Server R2 SP1 QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.1.x Yes Microsoft 2008 Windows Server R2 SP1 QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.2.x Yes Microsoft 2008 Windows Server R2 SP1 QLogic QxE256x 9.2.3.20 3.29 8.02.00 7.2.x Yes Microsoft 2008 Windows Server R2 SP1 QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.2.x Yes Microsoft 2008 Windows Server R2 SP1 QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes Microsoft 2008 Windows Server R2 SP1 QLogic QxE257x 9.1.13.20 3.24 7.04.00 6.7.x Yes Dell fw kit: 3.22.00 Microsoft 2008 Windows Server R2 SP1 QLogic QxE257x 9.1.15.21 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.22.07 Microsoft 2008 Windows Server R2 SP1 QLogic QxE257x 9.1.8.6 3.31 4.06.01 6.7.x Yes Dell fw kit: 03.22.08 Microsoft 2008 Windows Server R2 SP1 QLogic QxE257x 9.1.8.6 3.31 4.06.01 7.1.x Yes Dell fw kit: 03.22.08 Microsoft 2008 Windows Server R2 SP1 QLogic QxE257x 9.1.8.6 3.31 4.06.01 7.2.x Yes Dell fw kit: 03.22.08

38 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2008 Windows Server R2 SP1 QLogic QxE257x 9.2.3.20 3.4 8.05.00 7.2.x Yes Dell fw kit: 09.00.03 Microsoft 2008 Windows Server R2 SP1 QLogic QxE257x 9.2.3.20 3.4 8.05.00 7.3.x Yes Dell fw kit: 09.00.03 Microsoft 2008 Windows Server R2 SP1 QLogic QxE266x 9.1.13.20 - 8.00.00 6.7.x No Microsoft 2008 Windows Server R2 SP1 QLogic QxE266x 9.1.15.21 - 8.01.02 7.1.x No Microsoft 2008 Windows Server R2 SP1 QLogic QxE266x 9.1.17.21 - 8.03.01 7.1.x No Microsoft 2008 Windows Server R2 SP1 QLogic QxE266x 9.2.3.20 - 8.05.01 7.3.x No Microsoft 2008 Windows Server R2 SP1 QLogic QxE266x 9.2.3.20 3.32 8.03.01 7.2.x Yes Microsoft 2012 Windows Server QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.2.x Yes Microsoft 2012 Windows Server QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes Microsoft 2012 Windows Server QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.4.x Yes Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.19 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.19 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.19 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k)

39 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.19 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.19 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d) Microsoft 2012 Windows Server R2 Cisco VIC-13xx 2.4.0.20 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d) Microsoft 2012 Windows Server R2 Emulex LPe1200x/LPe1205 10.6.114.0 5.13a11 2.02A1 6.7.x Yes Microsoft 2012 Windows Server R2 Emulex LPe1200x/LPe1205 10.6.114.0 5.13a11 2.02A1 7.1.x Yes Microsoft 2012 Windows Server R2 Emulex LPe1200x/LPe1205 11.0.247.0 7.00.a2 2.02A1 7.1.x Yes Microsoft 2012 Windows Server R2 Emulex LPe1200x/LPe1205 11.0.247.0 7.00.a2 2.02A1 7.2.x Yes Microsoft 2012 Windows Server R2 Emulex LPe1200x/LPe1205 11.4.142.11 - 2.02a3 7.3.x No

40 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2012 Windows Server R2 Emulex LPe1200x/LPe1205 11.4.142.11 - 2.02A4 7.3.x No Microsoft 2012 Windows Server R2 Emulex LPe1200x/LPe1205 12.2.207.0 12.00a4 2.02A4 7.4.x Yes Microsoft 2012 Windows Server R2 Emulex LPe1200x/LPe1205 12.2.284.0 12.00a4 2.02A4 7.4.x Yes Microsoft 2012 Windows Server R2 Emulex LPe1200x/LPe1205 12.2.284.0 12.00a4 2.02A4 7.5.x Yes Microsoft 2012 Windows Server R2 Emulex LPx1500x/LPx1600x 10.6.114.0 10.6.144.21 10.6.144.21 6.7.x Yes Microsoft 2012 Windows Server R2 Emulex LPx1500x/LPx1600x 10.6.114.0 10.6.144.21 10.6.144.21 7.1.x Yes Microsoft 2012 Windows Server R2 Emulex LPx1500x/LPx1600x 10.6.114.0 11.0.270.9 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04 Microsoft 2012 Windows Server R2 Emulex LPx1500x/LPx1600x 10.6.114.0 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04 Microsoft 2012 Windows Server R2 Emulex LPx1500x/LPx1600x 11.2.139.0 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01 Microsoft 2012 Windows Server R2 Emulex LPx1500x/LPx1600x 11.2.139.0 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01 Microsoft 2012 Windows Server R2 Emulex LPx1500x/LPx1600x 12.2.207.0 12.0.257.12 12.0.257.12 7.4.x Yes Microsoft 2012 Windows Server R2 Emulex LPx1500x/LPx1600x 12.2.284.0 12.0.257.12 12.0.257.12 7.4.x Yes Microsoft 2012 Windows Server R2 Emulex LPx1500x/LPx1600x 12.2.284.0 12.0.257.19 12.0.257.19 7.5.x Yes Microsoft 2012 Windows Server R2 Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.142.23 11.4.142.23 7.2.x Yes Microsoft 2012 Windows Server R2 Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.142.23 11.4.142.23 7.3.x Yes Microsoft 2012 Windows Server R2 Emulex LPx3100x/LPx3200x 12.0.193.13 11.4.258.15 11.4.258.15 7.3.x Yes Dell fw kit: 2.03.02 Microsoft 2012 Windows Server R2 Emulex LPx3100x/LPx3200x 12.0.367.0 12.0.257.12 12.0.257.12 7.4.x Yes

41 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2012 Windows Server R2 Emulex LPx3100x/LPx3200x 12.2.284.0 12.2.350.10 12.2.350.10 7.4.x Yes Microsoft 2012 Windows Server R2 Emulex LPx3100x/LPx3200x 12.2.284.0 12.4.282.10 12.4.282.10 7.5.x Yes Microsoft 2012 Windows Server R2 Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.2.x No Microsoft 2012 Windows Server R2 Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.4.x No Microsoft 2012 Windows Server R2 Emulex LPx3500x 12.2.284.0 12.4.282.10 12.4.282.10 7.5.x No Microsoft 2012 Windows Server R2 QLogic QxE256x 9.1.13.20 3.27 7.04.00 6.7.x Yes Microsoft 2012 Windows Server R2 QLogic QxE256x 9.1.15.21 3.29 8.01.02 7.1.x Yes Microsoft 2012 Windows Server R2 QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.1.x Yes Microsoft 2012 Windows Server R2 QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE256x 9.2.3.20 3.29 8.01.02 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes Microsoft 2012 Windows Server R2 QLogic QxE256x 9.2.9.20 3.43 8.01.02 7.3.x Yes Microsoft 2012 Windows Server R2 QLogic QxE256x 9.2.9.20 3.43 8.01.02 7.4.x Yes Microsoft 2012 3.43 Windows Server R2 QLogic QxE256x 9.3.3.20 15.05.14 7.5.x Yes Microsoft 2012 Windows Server R2 QLogic QxE266x 9.1.13.20 3.27 7.04.01 6.7.x Yes Microsoft 2012 Windows Server R2 QLogic QxE266x 9.1.13.20 3.28 8.00.00 6.7.x Yes

42 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2012 Windows Server R2 QLogic QxE266x 9.1.13.20 3.29 7.04.00 6.7.x Yes Dell fw kit: 3.11.18 Microsoft 2012 Windows Server R2 QLogic QxE266x 9.1.15.21 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.11.25 Microsoft 2012 Windows Server R2 QLogic QxE266x 9.1.17.21 3.32 8.03.01 7.1.x Yes Microsoft 2012 Windows Server R2 QLogic QxE266x 9.1.17.21 3.32 8.03.01 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE266x 9.1.18.20 3.44 8.03.01 7.1.x Yes Dell fw kit: 08.00.15 Microsoft 2012 Windows Server R2 QLogic QxE266x 9.1.18.20 3.44 8.03.01 7.2.x Yes Dell fw kit: 08.00.15 Microsoft 2012 Windows Server R2 QLogic QxE266x 9.2.3.20 3.32 8.03.01 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE266x 9.2.3.20 3.43 8.05.01 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE266x 9.2.3.20 3.43 8.05.01 7.3.x Yes Microsoft 2012 Windows Server R2 QLogic QxE266x 9.2.3.22 3.43 8.05.01 7.2.x Yes Dell fw kit: 09.00.06 Microsoft 2012 Windows Server R2 QLogic QxE266x 9.2.3.22 3.43 8.05.01 7.3.x Yes Dell fw kit: 09.00.06 Microsoft 2012 Windows Server R2 QLogic QxE266x 9.2.9.20 3.45 8.07.11 7.3.x Yes Microsoft 2012 Windows Server R2 QLogic QxE266x 9.2.9.20 3.45 8.07.11 7.4.x Yes Microsoft 2012 Windows Server R2 QLogic QxE266x 9.2.9.20 3.45 8.07.11 7.5.x Yes Microsoft 2012 Windows Server R2 QLogic QxE269x 9.2.3.20 3.38 8.03.05 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.3.x Yes

43 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2012 Windows Server R2 QLogic QxE269x 9.2.9.20 3.62 8.07.80 7.3.x Yes Microsoft 2012 Windows Server R2 QLogic QxE269x 9.2.9.20 3.62 14.07.05 7.3.x Yes Microsoft 2012 Windows Server R2 QLogic QxE269x 9.2.9.20 3.62 8.07.80 7.4.x Yes Microsoft 2012 Windows Server R2 QLogic QxE269x 9.3.3.20 3.62 8.08.231 7.5.x Yes Microsoft 2012 Windows Server R2 QLogic QxE274x 9.1.17.21 - 8.03.04 7.1.x No Microsoft 2012 Windows Server R2 QLogic QxE274x 9.2.3.20 3.38 8.03.05 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.3.x Yes Microsoft 2012 Windows Server R2 QLogic QxE274x 9.2.9.20 3.62 8.07.80 7.3.x Yes Microsoft 2012 Windows Server R2 QLogic QxE274x 9.2.9.20 3.62 8.07.80 7.4.x Yes Microsoft 2012 Windows Server R2 QLogic QxE274x 9.3.3.20 3.62 8.08.231 7.5.x Yes Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.7 2.2(8d) 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2(8d) Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.7 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.7 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.8 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a) Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.8 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c) Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.8 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g)

44 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.8 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g) Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.8 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e) Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.8 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e) Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.8 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j) Microsoft 2016 Windows Server Cisco VIC-13xx 3.0.0.8 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j) Microsoft 2016 Windows Server Cisco VIC-13xx 3.1.0.11 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d) Microsoft 2016 Windows Server Cisco VIC-13xx 3.1.0.11 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d) Microsoft 2016 Windows Server Cisco VIC-14xx 3.1.0.11 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a) Microsoft 2016 Windows Server Cisco VIC-14xx 3.1.0.11 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a) Microsoft 2016 Windows Server Emulex LPx1500x/LPx1600x 11.0.247.0 11.0.270.2002 11.0.270.2002 6.7.x Yes Microsoft 2016 Windows Server Emulex LPx1500x/LPx1600x 11.0.247.0 11.0.270.2002 11.0.270.2002 7.1.x Yes Microsoft 2016 Windows Server Emulex LPx1500x/LPx1600x 11.0.247.0 11.0.270.2002 11.0.270.2002 7.2.x Yes Microsoft 2016 Windows Server Emulex LPx1500x/LPx1600x 12.2.284.0 12.0.257.12 12.0.257.12 7.5.x Yes Microsoft 2016 Windows Server Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.142.23 11.4.142.23 7.2.x Yes Microsoft 2016 Windows Server Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.142.23 11.4.142.23 7.3.x Yes Microsoft 2016 Windows Server Emulex LPx3100x/LPx3200x 12.0.193.13 11.4.258.15 11.4.258.15 7.3.x Yes Dell fw kit: 2.03.02 Microsoft 2016 Windows Server Emulex LPx3100x/LPx3200x 12.0.193.13 12.0.257.12 12.0.257.12 7.4.x Yes

45 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2016 Windows Server Emulex LPx3100x/LPx3200x 12.2.284.0 12.2.350.10 12.2.350.10 7.4.x Yes Microsoft 2016 Windows Server Emulex LPx3100x/LPx3200x 12.2.284.0 12.2.350.10 12.2.350.10 7.5.x Yes Microsoft 2016 Windows Server Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.3.x No Microsoft 2016 Windows Server Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.4.x No Microsoft 2016 Windows Server Emulex LPx3500x 12.2.284.0 - 12.2.350.12 7.4.x No Microsoft 2016 Windows Server Emulex LPx3500x 12.4.284.0 12.4.282.9 12.4.282.10 7.5.x Yes Microsoft 2016 Windows Server QLogic QxE256x 9.1.17.21 3.29 8.01.02 6.7.x Yes Microsoft 2016 Windows Server QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.1.x Yes Microsoft 2016 Windows Server QLogic QxE256x 9.1.17.21 3.29 8.01.02 7.2.x Yes Microsoft 2016 Windows Server QLogic QxE256x 9.2.3.20 3.29 8.01.02 7.2.x Yes Microsoft 2016 Windows Server QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.2.x Yes Microsoft 2016 Windows Server QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes Microsoft 2016 Windows Server QLogic QxE256x 9.2.9.20 3.43 8.01.02 7.4.x Yes Microsoft 2016 Windows Server QLogic QxE256x 9.2.9.23 3.45 8.08.01 7.5.x Yes Microsoft 2016 Windows Server QLogic QxE266x 9.1.17.21 3.32 8.03.01 6.7.x Yes Microsoft 2016 Windows Server QLogic QxE266x 9.1.17.21 3.32 8.03.01 7.1.x Yes Microsoft 2016 Windows Server QLogic QxE266x 9.1.17.21 3.32 8.03.01 7.2.x Yes

46 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2016 Windows Server QLogic QxE266x 9.2.3.20 3.32 8.03.01 7.2.x Yes Microsoft 2016 Windows Server QLogic QxE266x 9.2.3.20 3.43 8.05.01 7.2.x Yes Microsoft 2016 Windows Server QLogic QxE266x 9.2.3.20 3.43 8.05.01 7.3.x Yes Microsoft 2016 Windows Server QLogic QxE266x 9.2.9.20 3.43 8.05.01 7.4.x Yes Microsoft 2016 Windows Server QLogic QxE266x 9.2.9.23 3.62 8.08.232 7.5.x Yes Microsoft 2016 Windows Server QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.2.x Yes Microsoft 2016 Windows Server QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.3.x Yes Microsoft 2016 Windows Server QLogic QxE269x 9.2.9.20 3.43 8.05.00 7.4.x Yes Microsoft 2016 Windows Server QLogic QxE269x 9.2.9.20 3.62 8.07.80 7.3.x Yes Microsoft 2016 Windows Server QLogic QxE269x 9.3.3.20 3.62 9.03.40 7.5.x Yes Microsoft 2016 Windows Server QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.2.x Yes Microsoft 2016 Windows Server QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.3.x Yes Microsoft 2016 Windows Server QLogic QxE274x 9.2.9.20 3.43 8.05.00 7.4.x Yes Microsoft 2016 Windows Server QLogic QxE274x 9.2.9.20 3.62 8.07.80 7.3.x Yes Microsoft 2016 Windows Server QLogic QxE274x 9.3.3.20 3.62 8.08.231 7.5.x Yes Microsoft 2019 Windows Server Cisco VIC-14xx 3.2.0.14 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a) Microsoft 2019 Windows Server Cisco VIC-14xx 3.2.0.14 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a)

47 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2019 Windows Server Emulex LPe1200x/LPe1205 11.4.142.11 12.00a4 2.02A4 7.3.x Yes Microsoft 2019 Windows Server Emulex LPe1200x/LPe1205 12.0.367.0 12.00a4 2.02A4 7.4.x Yes Microsoft 2019 Windows Server Emulex LPe1200x/LPe1205 12.2.284.0 12.00a4 2.02A4 7.4.x Yes Microsoft 2019 Windows Server Emulex LPe1200x/LPe1205 12.6.165.0 12.00a4 2.02A4 7.5.X Yes Microsoft 2019 Windows Server Emulex LPx1500x/LPx1600x 11.4.142.11 11.4.142.23 11.4.142.23 7.3.x Yes Microsoft 2019 Windows Server Emulex LPx1500x/LPx1600x 12.0.367.0 11.4.142.23 11.4.142.23 7.4.x Yes Microsoft 2019 Windows Server Emulex LPx1500x/LPx1600x 12.2.284.0 11.4.142.23 11.4.142.23 7.4.x Yes Microsoft 2019 Windows Server Emulex LPx1500x/LPx1600x 12.6.165.0 12.0.257.12 12.0.257.12 7.5.x Yes Microsoft 2019 Windows Server Emulex LPx3100x/LPx3200x 11.4.142.11 11.4.258.12 11.4.258.15 7.3.x Yes Microsoft 2019 Windows Server Emulex LPx3100x/LPx3200x 11.4.142.11 12.0.257.12 12.0.257.12 7.4.x Yes Microsoft 2019 Windows Server Emulex LPx3100x/LPx3200x 12.2.284.0 12.2.350.10 12.2.350.10 7.4.x Yes Microsoft 2019 12.6.165.0 12.4.282.9 12.4.282.10 Windows Server Emulex LPx3100x/LPx3200x 7.5.x Yes Microsoft 2019 Windows Server Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.3.x No Microsoft 2019 Windows Server Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.4.x No Microsoft 2019 Windows Server Emulex LPx3500x 12.2.284.0 - 12.2.350.12 7.4.x No Microsoft 2019 Windows Server Emulex LPx3500x 12.6.165.0 12.4.282.9 12.4.282.10 7.5.x No Microsoft 2019 Windows Server QLogic QxE256x 9.2.3.20 3.43 8.01.02 7.3.x Yes

48 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2019 Windows Server QLogic QxE256x 9.2.8.21 3.43 8.01.02 7.4.x Yes Microsoft 2019 Windows Server QLogic QxE256x 9.2.9.23 3.45 8.08.01 7.5.x Yes Microsoft 2019 Windows Server QLogic QxE266x 9.2.3.20 - 8.05.01 7.3.x No Microsoft 2019 Windows Server QLogic QxE266x 9.2.8.21 - 8.05.01 7.4.x No Microsoft 2019 9.2.9.23 3.62 8.08.232 Windows Server QLogic QxE266x 7.5.x No Microsoft 2019 Windows Server QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.3.x Yes Microsoft 2019 Windows Server QLogic QxE269x 9.2.9.23 3.43 8.05.00 7.4.x Yes Microsoft 2019 Windows Server QLogic QxE269x 9.2.9.23 3.62 9.03.40 7.5.x Yes Microsoft 2019 Windows Server QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.3.x Yes Microsoft 2019 Windows Server QLogic QxE274x 9.2.9.23 3.43 8.05.00 7.4.x Yes Microsoft 2019 9.2.9.23 3.62 8.08.231 Windows Server QLogic QxE274x 7.5.x Yes Oracle Linux Server 6.x UEK QLogic QxE266x 8.05.00.03.39.0-k 3.24 7.03.00 6.7.x Yes Oracle Linux Server 7.x UEK Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 6.7.x Yes Oracle Linux Server 7.x UEK Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.1.x Yes Oracle Linux Server 7.x UEK Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.2.x Yes Oracle Linux Server 7.x UEK Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.3.x Yes Oracle Linux Server 7.x UEK Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.4.x Yes

49 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Oracle Linux Server 7.x UEK Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 6.7.x Yes Oracle Linux Server 7.x UEK Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 7.1.x Yes Oracle Linux Server 7.x UEK Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 7.2.x Yes Oracle Linux Server 7.x UEK Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 7.3.x Yes Oracle Linux Server 7.x UEK Emulex LPx3100x/LPx3200x 11.1.0.4 11.0.270.9 11.0.270.18 7.4.x Yes Oracle Linux Server 7.x UEK QLogic QxE256x 8.07.00.16.39.0-k 3.24 7.05.00 6.7.x Yes Oracle Linux Server 7.x UEK QLogic QxE256x 8.07.00.26.39.0-k 3.24 8.02.00 7.1.x Yes Oracle Linux Server 7.x UEK QLogic QxE256x 8.07.00.38.40.0-k 3.29 8.01.02 6.7.x Yes Oracle Linux Server 7.x UEK QLogic QxE256x 8.07.00.38.40.0-k 3.29 8.01.02 7.1.x Yes Oracle Linux Server 7.x UEK QLogic QxE256x 8.07.00.38.40.0-k 3.29 8.01.02 7.2.x Yes Oracle Linux Server 7.x UEK QLogic QxE256x 9.00.00.00.40.0-k 3.29 8.01.02 7.3.x Yes Oracle Linux Server 7.x UEK QLogic QxE256x 9.00.00.00.40.0-k 3.29 8.01.02 7.4.x Yes Oracle Linux Server 7.x UEK QLogic QxE266x 8.07.00.16.39.0-k 3.24 7.03.00 6.7.x Yes Oracle Linux Server 7.x UEK QLogic QxE266x 8.07.00.26.39.0-k 3.24 7.03.00 7.1.x Yes Oracle Linux Server 7.x UEK QLogic QxE266x 8.07.00.38.40.0-k 3.32 8.03.01 6.7.x Yes Oracle Linux Server 7.x UEK QLogic QxE266x 8.07.00.38.40.0-k 3.32 8.03.01 7.1.x Yes Oracle Linux Server 7.x UEK QLogic QxE266x 8.07.00.38.40.0-k 3.32 8.03.01 7.2.x Yes

50 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Oracle Linux Server 7.x UEK QLogic QxE266x 9.00.00.00.40.0-k 3.32 8.03.01 7.3.x Yes Oracle Linux Server 7.x UEK QLogic QxE266x 9.00.00.00.40.0-k 3.32 8.03.01 7.4.x Yes Oracle Linux Server 7.x UEK QLogic QxE269x 8.07.00.38.40.0-k 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06 Oracle Linux Server 7.x UEK QLogic QxE269x 8.07.00.38.40.0-k 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06 Oracle Linux Server 7.x UEK QLogic QxE269x 8.07.00.38.40.0-k 3.43 8.05.00 7.4.x Yes Dell fw kit: 09.00.06 Oracle Linux Server 7.x UEK QLogic QxE274x 8.07.00.38.40.0-k 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06 Oracle Linux Server 7.x UEK QLogic QxE274x 8.07.00.38.40.0-k 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06 Oracle Linux Server 7.x UEK QLogic QxE274x 8.07.00.38.40.0-k 3.43 8.05.00 7.4.x Yes Dell fw kit: 09.00.06 Oracle Linux Server 8.x UEK Emulex LPx1500x/LPx1600x 12.6.0.3 12.0.257.12 12.0.257.12 7.5.x Yes Oracle Linux Server 8.x UEK Emulex LPx3100x/LPx3200x 12.6.0.3 12.0.257.12 12.0.257.12 7.5.x Yes Oracle Linux Server 8.x UEK QLogic QxE256x 10.01.00.22.81.1-k 3.45 8.07.00 7.5.x Yes Oracle Linux Server 8.x UEK QLogic QxE266x 10.01.00.22.81.1-k 3.24 7.03.00 7.5.x Yes Oracle Linux Server 8.x UEK QLogic QxE269x 10.01.00.22.81.1-k 3.43 8.05.00 7.5.x Yes Oracle Linux Server 8.x UEK QLogic QxE274x 10.01.00.22.81.1-k 3.62 8.08.231 7.5.x Yes Oracle OVM 3.3.1 QLogic QxE256x 8.07.00.16.39.0-k - 7.01.00 6.7.x No Oracle OVM 3.3.1 QLogic QxE266x 8.07.00.16.39.0-k - 7.00.01 6.7.x No Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 6.7.x Yes Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.1.x Yes Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.2.x Yes Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.1.0.4 11.0.270.9 11.0.270.2002 7.3.x Yes

51 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.4.0.7 12.0.257.12 12.0.257.12 7.4.x Yes Oracle OVM 3.4.x Emulex LPx1500x/LPx1600x 11.4.0.7 12.0.257.12 12.0.257.12 7.5.x Yes Oracle OVM 3.4.x Emulex LPx3100x/LPx3200x 11.4.0.7 12.0.257.12 12.0.257.12 7.4.x Yes Oracle OVM 3.4.x Emulex LPx3100x/LPx3200x 11.4.0.7 12.0.257.12 12.0.257.12 7.5.x Yes Oracle OVM 3.4.x QLogic QxE256x 8.07.00.26.39.0-k - 7.01.00 7.1.x No Oracle OVM 3.4.x QLogic QxE256x 8.07.00.38.40.0-k - 8.01.02 6.7.x No Oracle OVM 3.4.x QLogic QxE256x 8.07.00.38.40.0-k - 8.01.02 7.1.x No Oracle OVM 3.4.x QLogic QxE256x 8.07.00.38.40.0-k - 8.01.02 7.2.x No Oracle OVM 3.4.x QLogic QxE256x 8.07.00.38.40.0-k - 8.01.02 7.3.x No Oracle OVM 3.4.x QLogic QxE256x 9.00.00.00.41.0-k1 3.45 8.07.11 7.4.x Yes Oracle OVM 3.4.x QLogic QxE256x 9.00.00.00.41.0-k1 3.45 8.07.11 7.5.x Yes Oracle OVM 3.4.x QLogic QxE266x 8.07.00.26.39.0-k - 7.00.01 7.1.x No Oracle OVM 3.4.x QLogic QxE266x 8.07.00.38.40.0-k - 8.03.01 6.7.x No Oracle OVM 3.4.x QLogic QxE266x 8.07.00.38.40.0-k - 8.03.01 7.1.x No Oracle OVM 3.4.x QLogic QxE266x 8.07.00.38.40.0-k - 8.03.01 7.2.x No Oracle OVM 3.4.x QLogic QxE266x 8.07.00.38.40.0-k - 8.03.01 7.3.x No Oracle OVM 3.4.x QLogic QxE266x 9.00.00.00.41.0-k1 3.45 8.07.11 7.4.x Yes Oracle OVM 3.4.x QLogic QxE266x 9.00.00.00.41.0-k1 3.45 8.07.11 7.5.x Yes Oracle Solaris 10 SPARC QLogic QxE256x v20110825-3.06 3.27 7.04.00 6.7.x Yes Oracle Solaris 10 SPARC QLogic QxE256x v20110825-3.06 3.27 7.04.00 7.1.x Yes Oracle Solaris 10 SPARC QLogic QxE256x v20110825-3.06 3.27 7.04.00 7.2.x Yes Oracle Solaris 10 SPARC QLogic QxE256x v20110825-3.06 3.27 7.04.00 7.3.x Yes Oracle Solaris 10 SPARC QLogic QxE256x 170516-5.06c 3.29 8.05.00 7.4.x Yes Oracle Solaris 10 7.5.x Yes SPARC QLogic QxE256x 170516-5.06c 3.29 8.05.00 Oracle Solaris 10 x86_64 QLogic QxE256x v20110825-3.06 3.2 5.09.00 6.7.x Yes

52 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Oracle Solaris 10 x86_64 QLogic QxE256x v20110825-3.06 3.2 5.09.00 7.1.x Yes Oracle Solaris 10 x86_64 QLogic QxE256x v20110825-3.06 3.2 5.09.00 7.2.x Yes Oracle Solaris 10 x86_64 QLogic QxE256x v20110825-3.06 3.2 5.09.00 7.3.x Yes Oracle Solaris 10 x86_64 QLogic QxE256x 170516-5.06c 3.43 8.05.00 7.4.x Yes Oracle Solaris 10 7.5.x Yes x86_64 QLogic QxE256x 170516-5.06c 3.43 8.05.00 Oracle Solaris 11 SPARC Emulex LPe16002-o 3.3.00.1 12.0.193.34 12.0.193.34 7.3.x Yes Oracle Solaris 11 SPARC Emulex LPe16002-o 3.3.00.1 12.0.193.34 12.0.193.34 7.4.x Yes Oracle Solaris 11 SPARC Emulex LPe16002-o 3.3.00.1 12.0.193.34 12.0.193.34 7.5.x Yes Oracle Solaris 11 SPARC QLogic QxE256x 171019-5.07 3.43 8.05.00 6.7.x Yes Oracle Solaris 11 SPARC QLogic QxE256x 171019-5.07 3.43 8.05.00 7.2.x Yes Oracle Solaris 11 SPARC QLogic QxE256x 171019-5.07 3.43 8.05.00 7.3.x Yes Oracle Solaris 11 SPARC QLogic QxE256x 171019-5.07 3.43 8.05.00 7.4.x Yes Oracle Solaris 11 SPARC QLogic QxE256x 171019-5.07 3.43 8.05.00 7.5.x Yes Oracle Solaris 11 SPARC QLogic QxE256x v20120717-4.01 3.27 7.04.00 6.7.x Yes Oracle Solaris 11 SPARC QLogic QxE256x v20120717-4.01 3.27 7.04.00 7.1.x Yes Oracle Solaris 11 SPARC QLogic QxE256x v20120717-4.01 3.27 7.04.00 7.2.x Yes Oracle Solaris 11 SPARC QLogic QxE256x v20120717-4.01 3.27 7.04.00 7.3.x Yes

53 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Oracle Solaris 11 SPARC QLogic QxE274x 171019-5.07 3.62 8.07.70 6.7.x Yes Oracle Solaris 11 SPARC QLogic QxE274x 171019-5.07 3.62 8.07.70 7.2.x Yes Oracle Solaris 11 SPARC QLogic QxE274x 171019-5.07 3.62 8.07.70 7.3.x Yes Oracle Solaris 11 SPARC QLogic QxE274x 171019-5.07 3.62 8.07.70 7.4.x Yes Oracle Solaris 11 SPARC QLogic QxE274x 171019-5.07 3.62 8.07.70 7.5.x Yes Oracle Solaris 11 x86_64 Emulex LPe1200x/LPe1205 3.3.00.1 5.13a3 2.01a11 7.3.x Yes Oracle Solaris 11 x86_64 Emulex LPe1200x/LPe1205 3.3.00.1 5.13a3 2.01a11 7.4.x Yes Oracle Solaris 11 x86_64 Emulex LPe1200x/LPe1205 3.3.00.1 5.13a3 2.01a11 7.5.x Yes Oracle Solaris 11 x86_64 Emulex LPe1200x/LPe1205 v20120210-2.70i 5.13a3 2.01a11 6.7.x Yes Oracle Solaris 11 x86_64 Emulex LPe1200x/LPe1205 v20120210-2.70i 5.13a3 2.01a11 7.1.x Yes Oracle Solaris 11 x86_64 Emulex LPe1200x/LPe1205 v20120210-2.70i 5.13a3 2.01a11 7.2.x Yes Oracle Solaris 11 x86_64 Emulex LPe1200x/LPe1205 v20120210-2.70i 5.13a3 2.01a11 7.3.x Yes Oracle Solaris 11 x86_64 QLogic QxE256x 171019-5.07 3.29 8.05.00 7.3.x Yes Oracle Solaris 11 x86_64 QLogic QxE256x 171019-5.07 3.29 8.05.00 7.4.x Yes Oracle Solaris 11 x86_64 QLogic QxE256x 171019-5.07 3.29 8.05.00 7.5.x Yes Oracle Solaris 11 x86_64 QLogic QxE274x 171019-5.07 3.62 8.07.70 7.3.x Yes Oracle Solaris 11 x86_64 QLogic QxE274x 171019-5.07 3.62 8.07.70 7.4.x Yes

54 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Oracle Solaris 11 x86_64 QLogic QxE274x 171019-5.07 3.62 8.07.70 7.5.x Yes Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.27 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.34 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.34 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.37 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.37 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d) Red Hat RHEL 6.x Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d) Red Hat RHEL 6.x Cisco VIC-14xx 1.6.0.50 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a) Red Hat RHEL 6.x Cisco VIC-14xx 1.6.0.50 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a) Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 10.6.0.20 5.13a11 2.02A1 6.7.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 10.6.0.20 5.13a11 2.02A1 7.1.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 10.6.0.20 7.00a2 2.02A1 7.2.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.4 5.13a11 2.02A1 7.2.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.4 7.00a2 2.02A1 6.7.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.4 7.00a2 2.02A1 7.1.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.4 7.00a2 2.02A1 7.2.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.6 11.40a6 2.02a3 7.3.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.0.6 5.13a11 2.02A1 7.2.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.1.6 12.00a4 2.02A4 7.3.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 11.0.1.6 12.00a4 2.02A4 7.4.x Yes Red Hat RHEL 6.x Emulex LPe1200x/LPe1205 8.3.5.68.5p 5.13a10 2.01A12 6.7.x Yes

55 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Red Hat RHEL 6.x Emulex LPx1500x/LPx1600x 11.0.0.6 11.0.270.14 11.0.270.2002 7.2.x Yes Red Hat RHEL 6.x Emulex LPx1500x/LPx1600x 11.0.0.6 11.2.216.9 11.2.216.9 7.3.x Yes Red Hat RHEL 6.x Emulex LPx1500x/LPx1600x 11.0.1.6 11.4.258.16 11.4.258.16 7.3.x Yes Red Hat RHEL 6.x Emulex LPx1500x/LPx1600x 11.0.1.6 12.0.257.12 12.0.257.12 7.4.x Yes Red Hat RHEL 6.x Emulex LPx3100x/LPx3200x 11.0.1.6 11.0.270.18 11.0.270.18 7.3.x Yes Dell fw kit: 2.00.03 Red Hat RHEL 6.x Emulex LPx3100x/LPx3200x 11.0.1.6 11.0.270.18 11.0.270.18 7.4.x Yes Dell fw kit: 2.00.03 Red Hat RHEL 6.x QLogic QxE256x 8.05.00.03.06.5-k2 3.27 7.04.00 6.7.x Yes Red Hat RHEL 6.x QLogic QxE256x 8.07.00.16.06.7-k 3.29 8.01.02 6.7.x Yes Red Hat RHEL 6.x QLogic QxE256x 8.07.00.16.06.7-k 3.29 8.01.02 7.1.x Yes Red Hat RHEL 6.x QLogic QxE256x 8.07.00.16.06.7-k 3.29 8.01.02 7.2.x Yes Red Hat RHEL 6.x QLogic QxE256x 8.07.00.26.06.8-k 3.29 8.01.02 7.2.x Yes Red Hat RHEL 6.x QLogic QxE256x 8.07.00.26.06.8-k 3.43 8.07.00 7.3.x Yes Red Hat RHEL 6.x QLogic QxE256x 8.07.00.26.06.8-k 3.43 8.08.01 7.4.x Yes Red Hat RHEL 6.x QLogic QxE266x 8.07.00.26.06.8-k 3.17 6.04.00 7.2.x Yes Red Hat RHEL 6.x QLogic QxE266x 8.07.00.26.06.8-k 3.24 7.03.00 7.3.x Yes Red Hat RHEL 6.x QLogic QxE266x 8.07.00.26.06.8-k 3.24 7.03.00 7.4.x Yes Red Hat RHEL 6.x QLogic QxE269x 8.07.00.26.06.8-k 3.62 8.08.204 7.3.x Yes Dell fw kit: 14.10.05 Red Hat RHEL 6.x QLogic QxE269x 8.07.00.26.06.8-k 3.62 8.08.204 7.4.x Yes Dell fw kit: 14.10.05 Red Hat RHEL 6.x QLogic QxE274x 8.07.00.26.06.8-k 3.62 8.08.204 7.3.x Yes Dell fw kit: 14.10.05 Red Hat RHEL 6.x QLogic QxE274x 8.07.00.26.06.8-k 3.62 8.08.204 7.4.x Yes Dell fw kit: 14.10.05 Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.25 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.25 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.25 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.30 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.30 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.34 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.34 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.34 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.34 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.36 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.36 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g)

56 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d) Red Hat RHEL 7.x Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d) Red Hat RHEL 7.x Cisco VIC-14xx 2.0.0.42 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a) Red Hat RHEL 7.x Cisco VIC-14xx 2.0.0.42 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a) Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.2.8021.1 5.13a3 2.01A12 6.7.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 5.13a11 2.02A1 6.7.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 5.13a11 2.02A1 7.1.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 5.13a11 2.02A1 7.2.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 7.00a2 2.02A1 6.7.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 7.00a2 2.02A1 7.1.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 10.7.0.1 7.00a2 2.02A1 7.2.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 11.2.0.6 11.40a6 2.02a3 7.3.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 11.2.0.6 5.13a11 2.02A1 7.2.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 11.4.0.4 12.00a4 2.02A4 7.3.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 12.0.0.5 12.00a4 2.02A4 7.4.x Yes Red Hat RHEL 7.x Emulex LPe1200x/LPe1205 12.0.0.13 12.00a4 2.02A4 7.5.x Yes Red Hat RHEL 7.x Emulex LPx1500x/LPx1600x 11.2.0.6 11.0.270.14 11.0.270.2002 7.2.x Yes Red Hat RHEL 7.x Emulex LPx1500x/LPx1600x 11.2.0.6 11.2.216.9 11.2.216.9 7.3.x Yes Red Hat RHEL 7.x Emulex LPx1500x/LPx1600x 11.4.0.4 11.4.258.16 11.4.258.16 7.3.x Yes Red Hat RHEL 7.x Emulex LPx1500x/LPx1600x 12.0.0.5 12.0.257.12 12.0.257.12 7.4.x Yes Red Hat RHEL 7.x Emulex LPx1500x/LPx1600x 12.0.0.5 12.0.257.12 12.0.257.12 7.5.x Yes Red Hat RHEL 7.x Emulex LPx3100x/LPx3200x 11.2.0.6 11.4.165.16 11.4.165.16 7.3.x Yes Dell fw kit: 02.02.01 Red Hat RHEL 7.x Emulex LPx3100x/LPx3200x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.00.04 Red Hat RHEL 7.x Emulex LPx3100x/LPx3200x 11.4.0.4 11.4.258.15 11.4.258.15 7.3.x Yes Dell fw kit: 02.03.02 Red Hat RHEL 7.x Emulex LPx3100x/LPx3200x 11.4.0.4 12.0.257.12 12.0.257.12 7.4.x Yes Red Hat RHEL 7.x Emulex LPx3100x/LPx3200x 12.0.0.13 12.4.282.9 12.4.282.10 7.5.x Yes Red Hat RHEL 7.x Emulex LPx3500x 12.0.257.9 - 12.0.257.15 7.3.x No Red Hat RHEL 7.x Emulex LPx3500x 12.0.0.5 - 12.0.257.15 7.4.x No Dell fw kit: 3.00.12 Red Hat RHEL 7.x Emulex LPx3500x 12.0.0.13 12.4.282.9 12.4.282.10 7.5.x No Dell fw Kit: 3.02.18

57 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Red Hat RHEL 7.x QLogic QxE256x 10.00.00.06.07.6-k 3.43 8.08.01 7.4.x Yes Red Hat RHEL 7.x QLogic QxE256x 8.07.00.08.07.1-k2 3.27 7.04.00 6.7.x Yes Red Hat RHEL 7.x QLogic QxE256x 8.07.00.18.07.2-k 3.29 8.01.02 6.7.x Yes Red Hat RHEL 7.x QLogic QxE256x 8.07.00.18.07.2-k 3.29 8.01.02 7.1.x Yes Red Hat RHEL 7.x QLogic QxE256x 8.07.00.18.07.2-k 3.29 8.01.02 7.2.x Yes Red Hat RHEL 7.x QLogic QxE256x 8.07.00.38.07.4-k1 3.29 8.01.02 7.2.x Yes Red Hat RHEL 7.x QLogic QxE256x 8.07.00.38.07.4-k1 3.43 8.07.00 7.3.x Yes Red Hat RHEL 7.x QLogic QxE256x 9.00.00.00.07.5-k1 3.43 8.08.01 7.3.x Yes Red Hat RHEL 7.x QLogic QxE256x 10.01.00.20.07.8-k 3.45 8.08.207 7.5.x Yes Red Hat RHEL 7.x QLogic QxE266x 8.07.00.08.07.1-k2 3.28 8.00.00 6.7.x Yes Red Hat RHEL 7.x QLogic QxE266x 8.07.00.18.07.2-k 3.29 8.01.02 6.7.x Yes Red Hat RHEL 7.x QLogic QxE266x 8.07.00.18.07.2-k 3.29 8.01.02 7.1.x Yes Red Hat RHEL 7.x QLogic QxE266x 8.07.00.18.07.2-k 3.29 8.01.02 7.2.x Yes Red Hat RHEL 7.x QLogic QxE266x 8.07.00.38.07.4-k1 3.32 8.03.01 7.2.x Yes Red Hat RHEL 7.x QLogic QxE266x 8.07.00.38.07.4-k1 3.43 8.07.12 7.3.x Yes Red Hat RHEL 7.x QLogic QxE266x 9.00.00.00.07.5-k1 3.45 8.07.11 7.3.x Yes Red Hat RHEL 7.x QLogic QxE266x 10.00.00.06.07.6-k 3.45 8.07.11 7.4.x Yes Red Hat RHEL 7.x QLogic QxE266x 10.01.00.20.07.8-k 3.62 8.08.207 7.5.x Yes Red Hat RHEL 7.x QLogic QxE269x 8.07.00.38.07.4-k1 3.38 8.03.05 7.2.x Yes Dell fw kit: 08.00.15 Red Hat RHEL 7.x QLogic QxE269x 8.07.00.38.07.4-k1 3.38 8.03.05 7.3.x Yes Dell fw kit: 08.00.15 Red Hat RHEL 7.x QLogic QxE269x 9.00.00.00.07.5-k1 3.62 8.07.80 7.3.x Yes Dell fw kit: 14.04.09 Red Hat RHEL 7.x QLogic QxE269x 9.00.00.00.07.5-k1 3.62 8.07.80 7.4.x Yes Dell fw kit: 14.04.09 Red Hat RHEL 7.x QLogic QxE269x 10.01.00.20.07.8-k 3.62 8.08.231 7.5.x Yes Dell fw kit: 15.05.14 Red Hat RHEL 7.x QLogic QxE274x 8.07.00.38.07.4-k1 3.38 8.03.05 7.2.x Yes Dell fw kit: 08.00.14 Red Hat RHEL 7.x QLogic QxE274x 8.07.00.38.07.4-k1 3.38 8.03.05 7.3.x Yes Dell fw kit: 08.00.14 Red Hat RHEL 7.x QLogic QxE274x 9.00.00.00.07.5-k1 3.62 8.07.80 7.3.x Yes Dell fw kit: 14.04.09 Red Hat RHEL 7.x QLogic QxE274x 9.00.00.00.07.5-k1 3.62 8.07.80 7.4.x Yes Dell fw kit: 14.04.09 Red Hat RHEL 7.x QLogic QxE274x 10.01.00.20.07.8-k 3.62 8.08.231 7.5.x Yes Dell fw kit: 15.05.13 Red Hat RHEL 8.x Cisco VIC-13xx 1.6.0.34 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j) Red Hat RHEL 8.x Cisco VIC-13xx 1.6.0.34 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j) Red Hat RHEL 8.x Cisco VIC-13xx 1.6.0.34 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d)

58 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Red Hat RHEL 8.x Cisco VIC-13xx 1.6.0.34 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d) Red Hat RHEL 8.x Cisco VIC-14xx 1.6.0.34 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a) Red Hat RHEL 8.x Cisco VIC-14xx 1.6.0.34 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a) Red Hat RHEL 8.x Emulex LPe1200x/LPe1205 12.0.0.6 12.00a4 2.02A4 7.3.x Yes Red Hat RHEL 8.x Emulex LPe1200x/LPe1205 12.0.0.6 12.00a4 2.02A4 7.4.x Yes Red Hat RHEL 8.x Emulex LPe1200x/LPe1205 12.6.0.2 12.00a4 2.02A4 7.5.x Yes Red Hat RHEL 8.x Emulex LPx1500x/LPx1600x 12.0.0.6 11.4.258.16 11.4.258.16 7.3.x Yes Red Hat RHEL 8.x Emulex LPx1500x/LPx1600x 12.0.0.6 12.0.257.12 12.0.257.12 7.4.x Yes Red Hat RHEL 8.x Emulex LPx1500x/LPx1600x 12.6.0.2 12.0.257.12 12.0.257.19 7.5.x Yes Red Hat RHEL 8.x Emulex LPx3100x/LPx3200x 12.0.0.6 11.0.270.18 11.0.270.18 7.3.x Yes Dell fw kit: 2.00.03 Red Hat RHEL 8.x Emulex LPx3100x/LPx3200x 12.0.0.6 11.0.270.18 11.0.270.18 7.4.x Yes Dell fw kit: 2.00.03 Red Hat RHEL 8.x Emulex LPx3100x/LPx3200x 12.6.0.2 12.0.257.12 12.0.257.19 7.5.x Yes Dell fw kit: 03.00.14 Red Hat RHEL 8.x Emulex LPx3500x 12.6.0.2 12.4.282.9 12.4.282.10 7.5.x No Dell fw Kit: 03.02.18 10.00.00.07.08.0- Red Hat RHEL 8.x QLogic QxE256x k1 3.43 8.07.00 7.3.x Yes 10.00.00.07.08.0- Red Hat RHEL 8.x QLogic QxE256x k1 3.43 8.08.01 7.4.x Yes Red Hat RHEL 8.x QLogic QxE256x 10.01.00.21.08.2-k 3.43 8.08.01 7.5.x Yes 10.00.00.07.08.0- Red Hat RHEL 8.x QLogic QxE266x k1 3.24 7.03.00 7.3.x Yes 10.00.00.07.08.0- Red Hat RHEL 8.x QLogic QxE266x k1 3.24 7.03.00 7.4.x Yes Red Hat RHEL 8.x QLogic QxE266x 10.01.00.21.08.2-k 3.24 7.03.00 7.5.x Yes 10.00.00.07.08.0- Red Hat RHEL 8.x QLogic QxE269x k1 3.62 8.08.204 7.3.x Yes Dell fw kit: 14.10.05 10.00.00.07.08.0- Red Hat RHEL 8.x QLogic QxE269x k1 3.62 8.08.204 7.4.x Yes Dell fw kit: 14.10.05 Red Hat RHEL 8.x QLogic QxE269x 10.01.00.21.09.2-k 3.62 8.08.231 7.5.x Yes Dell fw kit: 15.05.14 10.00.00.07.08.0- Red Hat RHEL 8.x QLogic QxE274x k1 3.62 8.08.204 7.3.x Yes Dell fw kit: 14.10.05 10.00.00.07.08.0- Red Hat RHEL 8.x QLogic QxE274x k1 3.62 8.08.204 7.4.x Yes Dell fw kit: 14.10.05

59 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Red Hat RHEL 8.x QLogic QxE274x 10.01.00.21.08.2-k 3.62 8.08.231 7.5.x Yes Dell fw kit: 15.05.13 SUSE SLES 11 SP3 QLogic QxE266x 8.04.00.13.11.3-k 3.28 8.00.00 6.7.x Yes SUSE SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.29 8.01.02 6.7.x Yes SUSE SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.29 8.01.02 7.1.x Yes SUSE SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.29 8.01.02 7.2.x Yes SUSE SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.32 8.03.01 7.2.x Yes SUSE SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.43 8.05.01 7.3.x Yes SUSE SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.45 8.07.11 7.3.x Yes SUSE SLES 11 SP4 QLogic QxE266x 8.07.00.18-k 3.45 8.07.11 7.4.x Yes SUSE SLES 12 Emulex LPe1200x/LPe1205 10.2.8040.1 5.13a0 2.01A12 6.7.x Yes SUSE SLES 12 SP1 Emulex LPe1200x/LPe1205 10.5.0.2 5.13a11 2.02A1 6.7.x Yes SUSE SLES 12 SP1 Emulex LPe1200x/LPe1205 10.5.0.2 5.13a11 2.02A1 7.1.x Yes SUSE SLES 12 SP1 Emulex LPe1200x/LPe1205 10.5.0.2 5.13a11 2.02A1 7.2.x Yes SUSE SLES 12 SP1 Emulex LPe1200x/LPe1205 10.5.0.2 7.00a2 2.02A1 7.2.x Yes SUSE SLES 12 SP1 Emulex LPe1200x/LPe1205 11.1.0.1 5.13a11 2.02A1 7.2.x Yes SUSE SLES 12 SP1 Emulex LPe1200x/LPe1205 11.4.0.1 11.40a6 2.02a3 7.3.x Yes SUSE SLES 12 SP1 Emulex LPe1200x/LPe1205 11.4.0.5 12.00a4 2.02A4 7.3.x Yes SUSE SLES 12 SP1 Emulex LPe1200x/LPe1205 11.4.0.7-1 12.00a4 2.02A4 7.4.x Yes SUSE SLES 12 SP4 Emulex LPe1200x/LPe1205 12.0.0.6 12.00a4 2.02A4 7.5.x Yes SUSE SLES 15 QLogic QxE266x 10.00.00.08-k 3.45 8.07.11 7.3.x Yes SUSE SLES 15 QLogic QxE266x 10.00.00.08-k 3.45 8.07.11 7.4.x Yes SUSE SLES 15 SP1 QLogic QxE266x 10.00.00.13-k 3.62 8.08.207 7.5.x Yes Ubuntu 18.4 Emulex LPx1500x/LPx1600x 12.0.0.0 12.0.257.12 12.0.257.12 7.3.x Yes Ubuntu 18.4 Emulex LPx1500x/LPx1600x 12.0.0.0 12.0.257.12 12.0.257.12 7.4.x Yes Ubuntu 18.4 Emulex LPx3100x/LPx3200x 12.0.0.0 12.0.257.12 12.0.257.12 7.3.x Yes Ubuntu 18.4 Emulex LPx3100x/LPx3200x 12.0.0.0 12.0.257.12 12.0.257.12 7.4.x Yes Ubuntu 18.4 QLogic QxE266x 10.00.00.02-k 3.45 8.07.11 7.3.x Yes Ubuntu 18.4 QLogic QxE266x 10.00.00.02-k 3.45 8.07.11 7.4.x Yes Ubuntu 18.4 QLogic QxE274x 10.00.00.02-k 3.62 8.07.80 7.3.x Yes Dell fw kit: 14.04.09 Ubuntu 18.4 QLogic QxE274x 10.00.00.02-k 3.62 8.07.80 7.4.x Yes Dell fw kit: 14.04.09 Ubuntu 20.04 Emulex LPx1500x/LPx1600x 12.6.0.4 12.0.257.12 12.0.257.19 7.5.x Yes

60 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version Ubuntu 20.04 Emulex LPx3100x/LPx3200x 12.6.0.4 12.4.282.9 12.4.282.10 7.5.x Yes Ubuntu 20.04 QLogic QxE266x 10.01.00.19-k 3.62 8.08.207 7.5.x Yes Ubuntu 20.04 QLogic QxE274x 10.01.00.19-k 3.62 8.08.231 7.5.x Yes Dell fw Kit: 15.05.13 VMware ESXi 5.5 Cisco VIC-13xx 1.6.0.16 3.0(2c) 3.0(2c) 6.7.x Yes VMware ESXi 5.5 Cisco VIC-13xx 1.6.0.28 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d VMware ESXi 5.5 Cisco VIC-13xx 1.6.0.28 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h) VMware ESXi 5.5 Cisco VIC-13xx 1.6.0.28 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k) VMware ESXi 5.5 Emulex LPx1500x/LPx1600x 10.6.126.0 10.6.133.18 10.6.133.18 6.7.x Yes Dell fw kit: 01.06.01 VMware ESXi 5.5 Emulex LPx1500x/LPx1600x 10.6.126.0 10.6.133.18 10.6.133.18 7.1.x Yes Dell fw kit: 01.06.01 VMware ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 6.7.x Yes Dell fw kit: 02.00.04 VMware ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04 VMware ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04 VMware ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 5.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 5.5 QLogic QxE257x 1.1.55.0 3.24 7.04.00 6.7.x Yes Dell fw kit: 3.22.00 VMware ESXi 5.5 QLogic QxE257x 1.1.55.0 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.22.07 VMware ESXi 5.5 QLogic QxE257x 1.1.55.0 3.31 8.01.02 7.1.x Yes Dell fw kit: 03.22.08 VMware ESXi 5.5 QLogic QxE257x 1.1.55.0 3.31 8.01.02 7.2.x Yes Dell fw kit: 03.22.08 VMware ESXi 5.5 QLogic QxE257x 1.1.70.0 3.31 8.01.02 6.7.x Yes Dell fw kit: 03.22.08 VMware ESXi 5.5 QLogic QxE257x 1.1.70.0 3.31 8.01.02 7.2.x Yes Dell fw kit: 03.22.08 VMware ESXi 5.5 QLogic QxE257x 1.1.70.0 3.4 8.01.02 7.2.x Yes Dell fw kit: 09.00.03 VMware ESXi 5.5 QLogic QxE257x 1.1.70.0 3.4 8.01.02 7.3.x Yes Dell fw kit: 09.00.03 VMware ESXi 5.5 QLogic QxE266x 1.1.55.0 3.29 7.04.00 6.7.x Yes Dell fw kit: 3.11.18 VMware ESXi 5.5 QLogic QxE266x 1.1.70.0 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.11.25 VMware ESXi 5.5 QLogic QxE266x 1.1.70.0 3.43 8.05.01 7.2.x Yes Dell fw kit: 09.00.06 VMware ESXi 5.5 QLogic QxE266x 1.1.70.0 3.43 8.05.01 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 5.5 QLogic QxE266x 1.1.70.0 3.44 8.03.01 7.1.x Yes Dell fw kit: 08.00.15 VMware ESXi 5.5 QLogic QxE266x 1.1.70.0 3.44 8.03.01 7.2.x Yes Dell fw kit: 08.00.15 VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.28 3.1(1h) 4.1(1f) 6.7.x Yes Cisco fw kit: 3.1(1h) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.28 3.1(1k) 4.1(1h) 6.7.x Yes Cisco fw kit: 3.1(1k) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.33 2.2.8d 4.1(2d) 6.7.x Yes Cisco fw kit: 2.2.8d

61 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.33 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.33 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3d) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3d) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e) VMware ESXi 6.0 Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e) VMware ESXi 6.0 Emulex LPe1200x/LPe1205 10.5.70.0 6.03X1 2.01A12 6.7.x Yes Dell fw kit: 01.06.01 VMware ESXi 6.0 Emulex LPe1200x/LPe1205 10.6.126.0 6.03X1 2.01A12 7.1.x Yes Dell fw kit: 01.06.01 VMware ESXi 6.0 Emulex LPe1200x/LPe1205 11.1.145.18 7.00x1 2.02A1 6.7.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.0 Emulex LPe1200x/LPe1205 11.1.145.18 7.00x1 2.02A1 7.1.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.0 Emulex LPe1200x/LPe1205 11.1.145.18 7.00x1 2.02A1 7.2.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.0 Emulex LPe1200x/LPe1205 11.2.156.20 6.03X1 2.02a3 7.2.x Yes Dell fw kit: 02.01.01* VMware ESXi 6.0 Emulex LPe1200x/LPe1205 11.4.142.11 6.03X1 2.02a3 7.3.x Yes Dell fw kit: 02.01.01* VMware ESXi 6.0 Emulex LPx1500x/LPx1600x 10.6.126.0 10.6.133.18 10.6.133.18 6.7.x Yes Dell fw kit: 01.06.01 VMware ESXi 6.0 Emulex LPx1500x/LPx1600x 10.6.126.0 10.6.133.18 10.6.133.18 7.1.x Yes Dell fw kit: 01.06.01 VMware ESXi 6.0 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.0 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.0 Emulex LPx1500x/LPx1600x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.0 Emulex LPx1500x/LPx1600x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.0 Emulex LPx3100x/LPx3200x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.0 Emulex LPx3100x/LPx3200x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.0 QLogic QxE257x 2.1.20.0 3.24 7.04.00 6.7.x Yes Dell fw kit: 3.22.00 VMware ESXi 6.0 QLogic QxE257x 2.1.24.0 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.22.07 VMware ESXi 6.0 QLogic QxE257x 2.1.24.0 3.31 8.01.02 7.1.x Yes Dell fw kit: 03.22.08 VMware ESXi 6.0 QLogic QxE257x 2.1.24.0 3.31 8.01.02 7.2.x Yes Dell fw kit: 03.22.08 VMware ESXi 6.0 QLogic QxE257x 2.1.43.0 3.31 8.01.02 6.7.x Yes Dell fw kit: 03.22.08 VMware ESXi 6.0 QLogic QxE257x 2.1.43.0 3.31 8.01.02 7.2.x Yes Dell fw kit: 03.22.08 VMware ESXi 6.0 QLogic QxE257x 2.1.50.0 3.4 8.02.00 7.2.x Yes Dell fw kit: 09.00.03

62 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version VMware ESXi 6.0 QLogic QxE257x 2.1.57.0 3.4 8.02.00 7.3.x Yes Dell fw kit: 09.00.03 VMware ESXi 6.0 QLogic QxE266x 2.1.20.0 3.29 7.04.00 6.7.x Yes Dell fw kit: 3.11.18 VMware ESXi 6.0 QLogic QxE266x 2.1.24.0 3.29 8.01.02 7.1.x Yes Dell fw kit: 03.11.25 VMware ESXi 6.0 QLogic QxE266x 2.1.43.0 3.44 8.03.01 7.1.x Yes Dell fw kit: 08.00.15 VMware ESXi 6.0 QLogic QxE266x 2.1.43.0 3.44 8.03.01 7.2.x Yes Dell fw kit: 08.00.15 VMware ESXi 6.0 QLogic QxE266x 2.1.50.0 3.43 8.05.01 7.2.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.0 QLogic QxE266x 2.1.57.0 3.43 8.05.01 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.0 QLogic QxE269x 2.1.50.0 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.0 QLogic QxE269x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.0 QLogic QxE274x 2.1.50.0 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.0 QLogic QxE274x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.28 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.28 3.1(2b) 4.1(2d) 6.7.x Yes Cisco fw kit: 3.1(2b) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3a) 4.1(3a) 6.7.x Yes Cisco fw kit: 3.1(3a) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3c) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3c) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3d) 4.1(3a) 7.1.x Yes Cisco fw kit: 3.1(3d) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.1.x Yes Cisco fw kit: 3.1(3g) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.34 3.1(3g) 4.1(3f) 7.2.x Yes Cisco fw kit: 3.1(3g) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.1.x Yes Cisco fw kit: 3.2(3e) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.37 3.2(3e) 4.2(3b) 7.2.x Yes Cisco fw kit: 3.2(3e) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.37 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.37 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d) VMware ESXi 6.5 Cisco VIC-13xx 1.6.0.47 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d) VMware ESXi 6.5 Cisco VIC-14xx 1.6.0.50 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a) VMware ESXi 6.5 Cisco VIC-14xx 1.6.0.50 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a) VMware ESXi 6.5 Emulex LPe1200x/LPe1205 12.0.257.5-1oem 12.00a4 2.02A4 7.3.x Yes VMware ESXi 6.5 Emulex LPe1200x/LPe1205 12.0.257.5-1oem 12.00a4 2.02A4 7.4.x Yes VMware ESXi 6.5 Emulex LPx1500x/LPx1600x 11.1.0.6 11.0.270.9 11.0.270.2002 6.7.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.5 Emulex LPx1500x/LPx1600x 11.1.0.6 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04

63 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version VMware ESXi 6.5 Emulex LPx1500x/LPx1600x 11.1.145.18 11.0.270.9 11.0.270.2002 7.2.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.5 Emulex LPx1500x/LPx1600x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.5 Emulex LPx1500x/LPx1600x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.5 Emulex LPx1500x/LPx1600x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.3.x Yes VMware ESXi 6.5 Emulex LPx1500x/LPx1600x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes VMware ESXi 6.5 Emulex LPx3100x/LPx3200x 11.2.156.20 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.5 Emulex LPx3100x/LPx3200x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.5 Emulex LPx3100x/LPx3200x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.3.x Yes VMware ESXi 6.5 Emulex LPx3100x/LPx3200x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes VMware ESXi 6.5 Emulex LPx3500x 12.0.257.5 12.0.257.12 12.0.257.15 7.3.x Yes VMware ESXi 6.5 Emulex LPx3500x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes VMware ESXi 6.5 QLogic QxE256x 2.1.74.0 3.27 7.4.0 7.3.x Yes VMware ESXi 6.5 QLogic QxE256x 2.1.74.0 3.27 7.4.0 7.4.x Yes VMware ESXi 6.5 QLogic QxE266x 2.1.43.0 3.44 8.03.01 6.7.x Yes Dell fw kit: 08.00.15 VMware ESXi 6.5 QLogic QxE266x 2.1.43.0 3.44 8.03.01 7.1.x Yes Dell fw kit: 08.00.15 VMware ESXi 6.5 QLogic QxE266x 2.1.43.0 3.44 8.03.01 7.2.x Yes Dell fw kit: 08.00.15 VMware ESXi 6.5 QLogic QxE266x 2.1.50.0 3.43 8.05.01 7.2.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.5 QLogic QxE266x 2.1.57.0 3.43 8.05.01 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.5 QLogic QxE266x 2.1.74.0 3.45 8.7.11 7.3.x Yes VMware ESXi 6.5 QLogic QxE266x 2.1.74.0 3.45 8.7.11 7.4.x Yes VMware ESXi 6.5 QLogic QxE269x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.5 QLogic QxE269x 2.1.74.0 3.62 8.07.80 7.3.x Yes VMware ESXi 6.5 QLogic QxE269x 2.1.74.0 3.62 8.07.80 7.4.x Yes VMware ESXi 6.5 QLogic QxE269x 9.2.3.20 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.5 QLogic QxE274x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.5 QLogic QxE274x 2.1.74.0 3.62 8.07.80 7.3.x Yes VMware ESXi 6.5 QLogic QxE274x 2.1.74.0 3.62 8.07.80 7.4.x Yes VMware ESXi 6.5 QLogic QxE274x 9.2.3.20 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.7 Cisco VIC-13xx 4.0.0.14 3.2(3j) 4.2(3b) 7.3.x Yes Cisco fw kit: 3.2(3j) VMware ESXi 6.7 Cisco VIC-13xx 4.0.0.14 3.2(3j) 4.2(3b) 7.4.x Yes Cisco fw kit: 3.2(3j) VMware ESXi 6.7 Cisco VIC-13xx 4.0.0.24 4.0(2d) 4.3(2b) 7.3.x Yes Cisco fw kit: 4.0(2d)

64 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version VMware ESXi 6.7 Cisco VIC-13xx 4.0.0.24 4.0(2d) 4.3(2b) 7.4.x Yes Cisco fw kit: 4.0(2d) VMware ESXi 6.7 Cisco VIC-14xx 4.0.0.35 4.0(4a) 5.0(3a) 7.3.x Yes Cisco fw kit: 4.0(4a) VMware ESXi 6.7 Cisco VIC-14xx 4.0.0.35 4.0(4a) 5.0(3a) 7.4.x Yes Cisco fw kit: 4.0(4a) VMware ESXi 6.7 Emulex LPe1200x/LPe1205 12.0.257.5-1oem 12.00a4 2.02A4 7.3.x Yes VMware ESXi 6.7 Emulex LPe1200x/LPe1205 12.0.257.5-1oem 12.00a4 2.02A4 7.4.x Yes VMware ESXi 6.7 Emulex LPe1200x/LPe1205 12.6.182.2 12.00a4 2.02A4 7.5.x Yes VMware ESXi 6.7 Emulex LPx1500x/LPx1600x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.3.x Yes VMware ESXi 6.7 Emulex LPx1500x/LPx1600x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes VMware ESXi 6.7 Emulex LPx1500x/LPx1600x 12.6.182.2 12.0.257.19 12.0.257.19 7.5.x Yes VMware ESXi 6.7 Emulex LPx3100x/LPx3200x 11.4.142.11 11.2.216.9 11.2.216.9 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.7 Emulex LPx3100x/LPx3200x 11.4.142.11 11.2.216.9 11.2.216.9 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.7 Emulex LPx3100x/LPx3200x 12.0.193.14 12.0.257.12 12.0.257.12 7.3.x Yes Dell fw kit: 3.00.12 VMware ESXi 6.7 Emulex LPx3100x/LPx3200x 12.0.193.14 12.0.257.12 12.0.257.12 7.4.x Yes Dell fw kit: 3.00.12 VMware ESXi 6.7 Emulex LPx3100x/LPx3200x 12.6.182.2 12.4.282.10 12.4.282.10 7.5.x Yes Dell fw kit: 3.02.18 VMware ESXi 6.7 Emulex LPx3500x 12.0.257.5 12.0.257.12 12.0.257.15 7.3.x Yes VMware ESXi 6.7 Emulex LPx3500x 12.0.257.5-1oem 12.0.257.12 12.0.257.15 7.4.x Yes VMware ESXi 6.7 Emulex LPx3500x 12.6.182.2 12.4.282.10 12.4.282.10 7.5.x Yes VMware ESXi 6.7 QLogic QxE256x 3.1.9.0 3.27 7.4.0 7.3.x Yes VMware ESXi 6.7 QLogic QxE256x 3.1.9.0 3.27 7.4.0 7.4.x Yes VMware ESXi 6.7 QLogic QxE256x 3.1.36.0 3.27 8.08.207 7.5.x Yes VMware ESXi 6.7 QLogic QxE266x 3.1.9.0 3.45 8.7.11 7.3.x Yes VMware ESXi 6.7 QLogic QxE266x 3.1.9.0 3.45 8.7.11 7.4.x Yes VMware ESXi 6.7 QLogic QxE266x 3.1.36.0 3.62 8.08.232 7.5.x Yes VMware ESXi 6.7 QLogic QxE269x 3.1.8.0 3.62 8.07.80 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.7 QLogic QxE269x 3.1.8.0 3.62 8.07.80 7.4.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.7 QLogic QxE269x 3.1.36.0 3.62 9.03.40 7.5.x Yes VMware ESXi 6.7 QLogic QxE274x 2.1.57.0 3.43 8.05.00 7.2.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.7 QLogic QxE274x 2.1.57.0 3.43 8.05.00 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.7 QLogic QxE274x 3.1.8.0 3.62 8.07.80 7.3.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.7 QLogic QxE274x 3.1.8.0 3.62 8.07.80 7.4.x Yes Dell fw kit: 09.00.06 VMware ESXi 6.7 QLogic QxE274x 3.1.36.0 3.62 8.08.231 7.5.x Yes

65 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel Adapters (SC and SCv Series)

Operating System FC Host Adapter Driver BootCode Firmware SC BfS Notes Version VMware ESXi 7.0 Emulex LPe1200x/LPe1205 12.4.293.3 12.00a4 2.02A4 7.4.x Yes VMware ESXi 7.0 Emulex LPe1200x/LPe1205 12.6.278.10 12.00a4 2.02A4 7.5.x Yes VMware ESXi 7.0 Emulex LPx1500x/LPx1600x 12.4.293.3 12.0.257.19 12.0.257.19 7.4.x Yes VMware ESXi 7.0 Emulex LPx1500x/LPx1600x 12.6.278.10 12.0.257.19 12.0.257.19 7.5.x Yes VMware ESXi 7.0 Emulex LPx3100x/LPx3200x 12.4.293.3 12.2.350.10 12.2.350.10 7.4.x Yes VMware ESXi 7.0 Emulex LPx3100x/LPx3200x 12.6.278.10 12.4.282.10 12.4.282.10 7.5.x Yes VMware ESXi 7.0 Emulex LPx3500x 12.4.293.3 12.2.350.12 12.2.350.12 7.4.x Yes VMware ESXi 7.0 Emulex LPx3500x 12.6.278.10 12.4.282.10 12.4.282.10 7.5.x Yes VMware ESXi 7.0 QLogic QxE256x 4.0.1.0 3.27 8.08.01 7.4.x Yes VMware ESXi 7.0 QLogic QxE256x 4.1.14.0 3.27 8.08.207 7.5.x Yes VMware ESXi 7.0 QLogic QxE266x 4.0.1.0 3.62 8.08.207 7.4.x Yes VMware ESXi 7.0 QLogic QxE266x 4.1.14.0 3.62 8.08.232 7.5.x Yes VMware ESXi 7.0 QLogic QxE269x 4.0.1.0 3.62 8.08.231 7.4.x Yes VMware ESXi 7.0 QLogic QxE269x 4.1.14.0 3.62 9.03.40 7.5.x Yes VMware ESXi 7.0 QLogic QxE274x 4.0.1.0 3.62 8.08.231 7.4.x Yes VMware ESXi 7.0 QLogic QxE274x 4.1.14.0 3.62 8.08.231 7.5.x Yes Note: Support for VMware ESXi 7.0 includes 7.0 Update 2

66 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (SC and SCv Series)

4.3 iSCSI Adapters

4.3.1 iSCSI converged network and host bus adapters (SC and SCv Series)

Operating System iSCSI Host Adapter Driver BootCode Firmware SC BfS Notes Version Citrix XenServer 7.2 Broadcom 578xx 1.714.1 - 14.02.12 7.3.x No Microsoft 2008 Windows Server R2 SP1 Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 6.7.x Yes Microsoft 2008 Windows Server R2 SP1 Emulex OCx1410x 10.6.126.0 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01 Microsoft 2008 Windows Server R2 SP1 Emulex OCx1410x 11.0.271.0 - 11.0.270.2007 7.2.x No Dell fw kit: 02.00.04 Microsoft 2008 Windows Server R2 SP1 Emulex OCx1410x 11.2.1099.0 - 11.2.1197.13 7.2.x No Dell fw kit: 02.01.01 Microsoft 2008 Windows Server R2 SP1 Emulex OCx1410x 11.2.1099.0 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01 Microsoft 2008 Windows Server R2 SP1 QLogic QLE406x 2.1.4.26 - 3.0.1.75 6.7.x Yes Microsoft 2008 Windows Server R2 SP1 QLogic QLE406x 2.1.4.26 - 3.0.1.75 7.1.x Yes Microsoft 2008 Windows Server R2 SP1 QLogic QLE406x 2.1.4.26 - 3.0.1.75 7.2.x Yes

67 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (SC and SCv Series)

Operating System iSCSI Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2008 Windows Server R2 SP1 QLogic QxE826x 2.1.6.10 2.0.1.35 2.10.29 6.7.x Yes Microsoft 2008 Windows Server R2 SP1 Broadcom 578xx 7.12.32.0 7.12.1 08.07.25 7.2.x Yes Microsoft 2008 Windows Server R2 SP1 Broadcom 578xx 7.14.1.1 7.15.0 14.02.12 7.3.x Yes Dell fw kit: 14.02.01 Microsoft 2012 Windows Server Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 6.7.x Yes Microsoft 2012 Windows Server Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01 Microsoft 2012 Windows Server QLogic QxE826x 2.1.6.10 2.0.1.35 2.10.29 6.7.x Yes Microsoft 2012 Windows Server Broadcom 578xx 7.0.13.51 7.15.0 14.02.01 7.3.x Yes Microsoft 2012 Windows Server Broadcom 578xx 7.12.32.0 7.12.1 08.07.25 7.2.x Yes Microsoft 2012 Windows Server R2 QLogic QL41xxx 8.33.5.2 14.07.07 7.5.x No Microsoft 2012 Windows Server R2 Emulex OCx1410x 10.6.114.0 10.6.133.18 10.6.133.18 6.7.x Yes Microsoft 2012 Windows Server R2 Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 6.7.x Yes Microsoft 2012 Windows Server R2 Emulex OCx1410x 10.6.116.0 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01 Microsoft 2012 Windows Server R2 Emulex OCx1410x 11.0.271.0 11.0.243.16 11.0.243.16 7.1.x Yes Microsoft 2012 Windows Server R2 Emulex OCx1410x 11.0.271.0 11.0.270.15 11.0.270.15 7.1.x Yes Dell fw kit: 02.00.01 Microsoft 2012 Windows Server R2 Emulex OCx1410x 11.0.271.0 11.0.270.2007 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04

68 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (SC and SCv Series)

Operating System iSCSI Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2012 Windows Server R2 Emulex OCx1410x 11.0.271.0 11.0.270.2007 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04 Microsoft 2012 Windows Server R2 Emulex OCx1410x 11.2.1153.23 11.2.197.13 11.2.197.13 7.2.x Yes Dell fw kit: 02.01.01 Microsoft 2012 Windows Server R2 Emulex OCx1410x 11.2.1153.23 11.2.197.13 11.2.197.13 7.3.x Yes Dell fw kit: 02.01.01 Microsoft 2012 Windows Server R2 QLogic QLE406x 2.1.4.27 - 3.0.1.75 6.7.x No Microsoft 2012 Windows Server R2 QLogic QLE406x 2.1.4.27 - 3.0.1.75 7.1.x No Microsoft 2012 Windows Server R2 QLogic QLE406x 2.1.4.27 - 3.0.1.75 7.2.x No Microsoft 2012 Windows Server R2 QLogic QxE826x 2.1.6.10 2.0.1.35 2.10.29 6.7.x Yes Microsoft 2012 Windows Server R2 QLogic QxE826x 2.1.6.10 2.21 4.18.04 6.7.x Yes Dell fw kit: 2.10.29 Microsoft 2012 Windows Server R2 QLogic QxE826x 2.1.6.10 2.22 4.18.04 7.1.x Yes Dell fw kit: 02.10.38 Microsoft 2012 Windows Server R2 QLogic QxE826x 2.1.6.10 2.22 4.18.04 7.2.x Yes Dell fw kit: 02.10.38 Microsoft 2012 Windows Server R2 QLogic QxE826x 2.1.6.10 2.22 4.20.21 7.2.x Yes Dell fw kit: 09.00.03 Microsoft 2012 Windows Server R2 QLogic QxE826x 2.1.6.10 2.22 4.20.21 7.3.x Yes Dell fw kit: 09.00.03 Microsoft 2012 Windows Server R2 Broadcom 578xx 7.12.32.0 7.12.1 08.07.25 7.2.x Yes Microsoft 2012 Windows Server R2 Broadcom 578xx 7.4.4.0 7.15.0 14.02.12 7.3.x Yes Microsoft 2012 Not recommended with XL710, Windows Server R2 QLogic QL41xxx 8.33.5.2 - 14.07.07 7.3.x No i350, or x540 in Storage Center Microsoft 2012 Not recommended with XL710, Windows Server R2 QLogic QL41xxx 8.33.5.2 - 14.07.07 7.4.x No i350, or x540 in Storage Center Microsoft 2016 Windows Server Emulex OCx1410x 11.0.271.0 - 11.0.270.2007 7.2.x No Dell fw kit: 02.00.04

69 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (SC and SCv Series)

Operating System iSCSI Host Adapter Driver BootCode Firmware SC BfS Notes Version Microsoft 2016 Windows Server Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.2.x No Dell fw kit: 02.01.01 Microsoft 2016 Windows Server Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01 Microsoft 2016 Windows Server Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.4.x No Dell fw kit: 02.01.01 Microsoft 2016 Windows Server Emulex OCx1410x 11.2.1153.23 11.2.1197.13 7.5.x No Dell fw kit: 02.01.01 Microsoft 2016 Windows Server Broadcom 578xx 7.14.4.0 - 14.02.12 7.3.x No Microsoft 2016 Not recommended with XL710, Windows Server QLogic QL41xxx 8.24.5 - 14.07.04 7.3.x No i350, or x540 in Storage Center Microsoft 2016 Not recommended with XL710, Windows Server QLogic QL41xxx 8.33.5.2 - 14.07.07 7.3.x No i350, or x540 in Storage Center Microsoft 2016 Not recommended with XL710, Windows Server QLogic QL41xxx 8.33.5.2 - 14.07.07 7.4.x No i350, or x540 in Storage Center Microsoft 2016 Windows Server QLogic QL41xxx 8.53.1.0 - 15.15.11 7.5.x No Microsoft 2019 Windows Server Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01 Microsoft 2019 Windows Server Emulex OCx1410x 11.2.1153.23 - 11.2.1197.13 7.4.x No Dell fw kit: 02.01.01 Microsoft 2019 11.2.1153.23 11.2.1197.13 11.2.1197.13 Windows Server Emulex OCx1410x 7.5.x No Dell fw kit: 02.01.01 Microsoft 2019 Not recommended with XL710, Windows Server QLogic QL41xxx 8.33.5.2 - 14.07.07 7.3.x No i350, or x540 in Storage Center Microsoft 2019 Not recommended with XL710, Windows Server QLogic QL41xxx 8.33.5.2 - 14.07.07 7.4.x No i350, or x540 in Storage Center Microsoft 2019 Windows Server QLogic QL41xxx 8.53.1.0 - 15.15.11 7.5.x No Red Hat RHEL 6.x Emulex OCx1410x 10.4.272.0r 10.2.506.19 1.05.01 6.7.x Yes Red Hat RHEL 6.x Emulex OCx1410x 10.4.272.0r 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01 5.02.00.00.06.03- Red Hat RHEL 6.x QLogic QLE406x k4 - 3.0.1.75 6.7.x No

70 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (SC and SCv Series)

Operating System iSCSI Host Adapter Driver BootCode Firmware SC BfS Notes Version 5.03.00.00.06.07- Red Hat RHEL 6.x QLogic QLE406x k0 - 3.0.1.75 6.7.x No 5.03.00.00.06.07- Red Hat RHEL 6.x QLogic QLE406x k0 - 3.0.1.75 7.1.x No 5.03.00.00.06.07- Red Hat RHEL 6.x QLogic QLE406x k0 - 3.0.1.75 7.2.x No Red Hat RHEL 6.x QLogic QxE826x 5.4.1.9.0.0-ko 2.0.1.35 2.10.29 6.7.x Yes Red Hat RHEL 6.x Broadcom 578xx 1.712.30.0 7.15.0 14.02.12 7.3.x Yes Red Hat RHEL 6.x Broadcom 578xx 1.712.30.6 7.14.10 14.02.12 7.3.x Yes Red Hat RHEL 6.x Broadcom 578xx 2.7.10.1 7.12.1 08.07.25 7.2.x Yes Red Hat RHEL 7.x Emulex OCx1410x 10.6.0.0r - 11.0.270.2007 6.7.x No Dell fw kit: 02.00.04 Red Hat RHEL 7.x Emulex OCx1410x 10.6.0.0r - 11.0.270.2007 7.2.x No Dell fw kit: 02.00.04 Red Hat RHEL 7.x Emulex OCx1410x 11.2.1.0 - 11.0.270.2007 7.3.x No Dell fw kit: 02.00.04 Red Hat RHEL 7.x Emulex OCx1410x 11.4.0.0r - 11.0.270.2007 7.2.x No Dell fw kit: 02.00.04 Red Hat RHEL 7.x Emulex OCx1410x 11.4.0.1 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01 Red Hat RHEL 7.x Emulex OCx1410x 11.4.0.1 - 11.2.1197.13 7.4.x No Dell fw kit: 02.01.01 Red Hat RHEL 7.x Emulex OCx1410x 12.0.0.0r 11.2.1197.13 11.2.1197.13 7.5.x No Dell fw kit: 02.01.01 5.02.04.06.05.10- Red Hat RHEL 7.x QLogic QLE406x d0 - 3.0.1.75 6.7.x No 5.04.00.00.07.02- Red Hat RHEL 7.x QLogic QLE406x k0 - 3.0.1.75 6.7.x No Red Hat RHEL 7.x Broadcom 578xx 2.7.10.1 7.12.1 08.07.25 7.2.x Yes Red Hat RHEL 7.x QLogic QL41xxx 8.33.0.20 - 14.07.07 7.3.x No SUSE SLES 11 SP3 Emulex OCx1410x 10.4.114.0 10.2.506.19 1.05.01 6.7.x Yes SUSE SLES 11 SP3 Emulex OCx1410x 10.6.0.2 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01 5.03.00.06.11.3- SUSE SLES 11 SP3 QLogic QLE406x k0 - 3.0.1.75 6.7.x No 5.03.00.00.11.4- SUSE SLES 11 SP3 QLogic QxE826x ko 2.0.1.35 2.10.29 6.7.x Yes SUSE SLES 11 SP3 Broadcom 578xx 2.7.6.2 7.12.1 08.07.25 7.2.x Yes 5.03.00.00.11.4- SUSE SLES 11 SP4 QLogic QLE406x k0 - 3.0.1.75 6.7.x No

71 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (SC and SCv Series)

Operating System iSCSI Host Adapter Driver BootCode Firmware SC BfS Notes Version 5.03.00.00.11.4- SUSE SLES 11 SP4 QLogic QLE406x k0 - 3.0.1.75 7.1.x No 5.03.00.00.11.4- SUSE SLES 11 SP4 QLogic QLE406x k0 - 3.0.1.75 7.2.x No SUSE SLES 12 Emulex OCx1410x 10.6.0.2 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01 SUSE SLES 12 Emulex OCx1410x 10.6.0.2 10.6.133.18 1.06.01 7.2.x Yes Dell fw kit: 01.06.01 5.04.00.00.12.0- SUSE SLES 12 QLogic QLE406x k3 - 3.0.1.75 6.7.x No SUSE SLES 12 Broadcom 578xx 2.7.10.1 7.14.10 14.02.12 7.3.x Yes SUSE SLES 12 SP1 Emulex OCx1410x 10.6.0.0 - 11.0.243.16 7.2.x No SUSE SLES 12 SP1 Emulex OCx1410x 11.0.0.0 - 11.0.270.2007 7.2.x No SUSE SLES 12 SP1 Emulex OCx1410x 11.0.230.0 - 11.0.243.16 7.1.x No SUSE SLES 12 SP1 Emulex OCx1410x 11.2.1.0 - 11.2.1197.13 7.3.x No Dell fw kit: 02.01.01 SUSE SLES 12 SP1 Emulex OCx1410x 11.2.1.0 - 11.2.1197.13 7.4.x No Dell fw kit: 02.01.01 5.04.00.00.12.1- SUSE SLES 12 SP1 QLogic QLE406x k0 - 3.0.1.75 6.7.x No SUSE SLES 12 SP4 Emulex OCx1410x 11.2.1.0 11.2.1197.13 7.5.x No Dell fw kit: 02.01.01 VMware ESXi 5.5 Emulex OCx1410x 10.2.309.5 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01 VMware ESXi 5.5 Emulex OCx1410x 10.6.150.3 10.6.133.18 10.6.133.18 6.7.x Yes Dell fw kit: 01.06.01 VMware ESXi 5.5 Emulex OCx1410x 10.6.163.0 10.2.506.19 1.05.01 6.7.x Yes VMware ESXi 5.5 Emulex OCx1410x 11.0.231.0 11.0.270.15 11.0.231.0 7.1.x Yes Dell fw kit: 02.00.03 VMware ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 6.7.x Yes Dell fw kit: 02.00.04 VMware ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04 VMware ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04 VMware ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 5.5 Emulex OCx1410x 11.1.145.8 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 5.5 QLogic QxE826x 644.55.34.0 2.21 4.18.04 6.7.x Yes Dell fw kit: 2.10.29 VMware ESXi 5.5 QLogic QxE826x 644.55.34.0-1 2.0.1.35 2.10.29 6.7.x Yes VMware ESXi 5.5 QLogic QxE826x 644.55.36.0 2.22 4.18.04 7.1.x Yes Dell fw kit: 02.10.37 VMware ESXi 5.5 QLogic QxE826x 644.55.37.0 2.22 4.18.04 7.1.x Yes Dell fw kit: 02.10.38 VMware ESXi 5.5 QLogic QxE826x 644.55.37.0 2.22 4.18.04 7.2.x Yes Dell fw kit: 02.10.38

72 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (SC and SCv Series)

Operating System iSCSI Host Adapter Driver BootCode Firmware SC BfS Notes Version VMware ESXi 5.5 QLogic QxE826x 644.55.37.0 2.22 4.20.21 7.2.x Yes Dell fw kit: 09.00.03 VMware ESXi 5.5 QLogic QxE826x 644.55.37.0 2.22 4.20.21 7.3.x Yes Dell fw kit: 09.00.03 VMware ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.1 08.07.25 7.2.x Yes VMware ESXi 5.5 Broadcom 578xx 2.712 7.14.10 14.02.12 7.3.x Yes VMware ESXi 5.5 Broadcom 578xx 2.712.30.v55.1 7.12.4 7.12.17 6.7.x Yes VMware ESXi 5.5 Broadcom 578xx 2.712.70.v55.3 7.12.1 08.07.25 6.7.x Yes VMware ESXi 5.5 Broadcom 578xx 2.712.70.v55.3 7.12.1 08.07.25 7.1.x Yes VMware ESXi 5.5 Broadcom 578xx 2.712.70.v55.3 7.12.1 08.07.25 7.2.x Yes VMware ESXi 5.5 Broadcom 578xx 2.712.70.v55.3 7.12.5 7.12.19 7.1.x Yes VMware ESXi 5.5 Broadcom 578xx 2.713.10.v55.3 7.15.0 10.01.00 7.2.x Yes Dell fw kit: 10.01.00 VMware ESXi 5.5 Broadcom 578xx 2.713.10.v55.3 7.15.0 10.01.00 7.3.x Yes Dell fw kit: 10.01.00 VMware ESXi 6.0 Emulex OCx1410x 10.2.309.6 10.6.133.18 1.06.01 7.1.x Yes Dell fw kit: 01.06.01 VMware ESXi 6.0 Emulex OCx1410x 11.0.231.0 11.0.270.2002 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.03 VMware ESXi 6.0 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.0 Emulex OCx1410x 11.1.145.8 11.0.270.2007 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.0 Emulex OCx1410x 11.2.1147.5 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.0 Emulex OCx1410x 11.4.142.11 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.0 QLogic QxE826x 644.55.34.0 2.21 4.18.04 6.7.x Yes Dell fw kit: 2.10.29 VMware ESXi 6.0 QLogic QxE826x 644.55.36.0 2.22 4.18.04 7.1.x Yes Dell fw kit: 02.10.38 VMware ESXi 6.0 QLogic QxE826x 644.55.36.0 2.22 4.18.04 7.2.x Yes Dell fw kit: 02.10.38 VMware ESXi 6.0 QLogic QxE826x 644.55.37.0 2.22 4.20.21 7.2.x Yes Dell fw kit: 09.00.03 VMware ESXi 6.0 QLogic QxE826x 644.6.06.0 2.22 4.20.21 7.3.x Yes Dell fw kit: 09.00.03 VMware ESXi 6.0 Broadcom 578xx 1.712.70.v55.5 7.12.1 08.07.25 7.2.x Yes VMware ESXi 6.0 Broadcom 578xx 2.712 7.13.54 08.07.25 7.3.x Yes Dell fw kit: 14.02.12 VMware ESXi 6.5 QLogic QxE826x 644.6.06.0 - 4.18.04 7.2.x No Dell fw kit: 02.10.38 VMware ESXi 6.5 QLogic QxE826x 644.6.06.0 - 4.20.21 7.2.x No Dell fw kit: 09.00.03 VMware ESXi 6.5 QLogic QxE826x 644.6.06.0 - 4.20.21 7.3.x No Dell fw kit: 09.00.03 VMware ESXi 6.5 Broadcom 578xx 2.713 7.14.10 14.02.12 7.3.x Yes VMware ESXi 6.5 Broadcom 578xx 2.713.10.v60.3 - N/A 7.2.x No Dell fw kit: 08.07.25 VMware ESXi 6.5 Broadcom 578xx 2.713.30.v60.5 - 10.01.00 7.2.x No Dell fw kit: 10.01.00

73 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (SC and SCv Series)

Operating System iSCSI Host Adapter Driver BootCode Firmware SC BfS Notes Version Not recommended with XL710, VMware ESXi 6.5 QLogic QL41xxx 1.0.22.0-1 - 14.03.03 7.2.x No i350, or x540 in Storage Center Not recommended with XL710, VMware ESXi 6.5 QLogic QL41xxx 1.0.22.0-1 - 14.03.03 7.3.x No i350, or x540 in Storage Center Not recommended with XL710, VMware ESXi 6.5 QLogic QL41xxx 1.0.22.0-1 - 14.03.03 7.4.x No i350, or x540 in Storage Center Not recommended with XL710, VMware ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.3.x No i350, or x540 in Storage Center Not recommended with XL710, VMware ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.4.x No i350, or x540 in Storage Center Not recommended with XL710, VMware ESXi 6.7 QLogic QL41xxx 2.19.9.0 - 15.15.11 7.5.x No i350, or x540 in Storage Center Not recommended with XL710, VMware ESXi 7.0 QLogic QL41xxx 2.19.9.0 - 15.15.11 7.5.x No i350, or x540 in Storage Center Note: Support for VMware ESXi 7.0 includes 7.0 Update 2

74 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Software iSCSI initiators (SC and SCv Series)

4.3.2 Software iSCSI initiators (SC and SCv Series) Software iSCSI initiators are typically provided by the host OS vendor and can be used with any industry-standards-based network interface controller (NIC). The following table provides guidance on which software iSCSI initiators have been tested and the support level for advanced features, such as boot from SAN.

If boot from SAN functionality is desired, it is advised that the design include one of the Adapters listed in section 4 to ensure the indicated support level.

Operating System SC Version BfS Notes Citrix XenServer 6.5 6.7.x No Citrix XenServer 6.5 7.1.x No Citrix XenServer 7.0 7.1.x No Citrix XenServer 7.0 7.2.x No Citrix XenServer 7.1 7.2.x No Citrix XenServer 7.2 7.2.x No Citrix XenServer 7.2 7.3.x Yes Citrix XenServer 7.4 7.3.x No Citrix XenServer 7.6 7.4.x No Citrix Hypervisor (XenServer) 8.0 7.3.x No Citrix Hypervisor (XenServer) 8.0 7.4.x No Citrix Hypervisor (XenServer) 8.2 7.5.x No HP HP-UX 11iv3 6.7.x No HP HP-UX 11iv3 7.1.x No HP HP-UX 11iv3 7.2.x No HP HP-UX 11iv3 7.3.x No HP HP-UX 11iv3 7.4.x No HP HP-UX 11iv3 7.5.x No IBM AIX 6.1 6.7.x No IBM AIX 6.1 7.1.x No IBM AIX 6.1 7.2.x No IBM AIX 6.1 7.3.x No IBM AIX 7.1 6.7.x No

75 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Software iSCSI initiators (SC and SCv Series)

Operating System SC Version BfS Notes IBM AIX 7.1 7.1.x No IBM AIX 7.1 7.2.x No IBM AIX 7.1 7.3.x No IBM AIX 7.2 6.7.x No IBM AIX 7.2 7.1.x No IBM AIX 7.2 7.2.x No IBM AIX 7.2 7.3.x No Microsoft 2008 Windows Server R2 SP1 6.7.x Yes Microsoft 2008 Windows Server R2 SP1 7.1.x Yes Microsoft 2008 Windows Server R2 SP1 7.2.x Yes Microsoft 2008 Windows Server R2 SP1 7.3.x Yes Microsoft 2012 Windows Server 6.7.x Yes Microsoft 2012 Windows Server 7.1.x Yes Microsoft 2012 Windows Server 7.2.x Yes Microsoft 2012 Windows Server 7.3.x Yes Microsoft 2012 Windows Server R2 6.7.x Yes Microsoft 2012 Windows Server R2 7.1.x Yes Microsoft 2012 Windows Server R2 7.2.x Yes Microsoft 2012 Windows Server R2 7.3.x Yes Microsoft 2012 Windows Server R2 7.4.x No Microsoft 2012 Windows Server R2 7.5.x Yes Microsoft 2016 Windows Server 6.7.x Yes Microsoft 2016 Windows Server 7.1.x Yes Microsoft 2016 Windows Server 7.2.x Yes Microsoft 2016 Windows Server 7.3.x Yes Microsoft 2016 Windows Server 7.4.x No Microsoft 2016 Windows Server 7.5.x No Microsoft 2019 Windows Server 7.3.x No Microsoft 2019 Windows Server 7.4.x No Microsoft 2019 Windows Server 7.5.x No

76 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Software iSCSI initiators (SC and SCv Series)

Operating System SC Version BfS Notes Oracle Linux Server 6.x UEK 6.7.x No Oracle Linux Server 7.x UEK 6.7.x No Oracle Linux Server 7.x UEK 7.1.x No Oracle Linux Server 7.x UEK 7.2.x No Oracle Linux Server 7.x UEK 7.3.x No Oracle Linux Server 7.x UEK 7.4.x No Oracle Linux Server 8.x UEK 7.5.x No Oracle OVM 3.4.x 7.3.x No Oracle OVM 3.4.x 7.4.x No Oracle OVM 3.4.x 7.5.x No Oracle Solaris 10 SPARC 6.7.x No Oracle Solaris 10 SPARC 7.1.x No Oracle Solaris 10 x86_64 6.7.x No Oracle Solaris 10 x86_64 7.1.x No Oracle Solaris 11 SPARC 6.7.x No Oracle Solaris 11 SPARC 7.1.x No Oracle Solaris 11 x86_64 7.1.x No Oracle Solaris 11 x86_64 7.2.x No Oracle Solaris 11 x86_64 7.3.x No Red Hat RHEL 6.x 6.7.x Yes Red Hat RHEL 6.x 7.1.x Yes Red Hat RHEL 6.x 7.2.x Yes Red Hat RHEL 6.x 7.3.x Yes Red Hat RHEL 6.x 7.4.x No Red Hat RHEL 7.x 6.7.x Yes Red Hat RHEL 7.x 7.1.x Yes Red Hat RHEL 7.x 7.2.x Yes Red Hat RHEL 7.x 7.3.x No Red Hat RHEL 7.x 7.4.x No Red Hat RHEL 7.x 7.5.x No

77 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Software iSCSI initiators (SC and SCv Series)

Operating System SC Version BfS Notes Red Hat RHEL 8.x 7.3.x No Red Hat RHEL 8.x 7.4.x No Red Hat RHEL 8.x 7.5.x No SUSE SLES 11 SP3 6.7.x Yes SUSE SLES 11 SP3 7.1.x Yes SUSE SLES 11 SP3 7.2.x Yes SUSE SLES 11 SP4 6.7.x No SUSE SLES 11 SP4 7.1.x No SUSE SLES 11 SP4 7.2.x No SUSE SLES 11 SP4 7.3.x No SUSE SLES 11 SP4 7.4.x No SUSE SLES 12 6.7.x No SUSE SLES 12 7.1.x Yes SUSE SLES 12 7.2.x Yes SUSE SLES 12 7.3.x Yes SUSE SLES 12 SP1 6.7.x No SUSE SLES 12 SP1 7.1.x No SUSE SLES 12 SP1 7.2.x No SUSE SLES 12 SP1 7.3.x No SUSE SLES 12 SP1 7.4.x No SUSE SLES 12 SP4 7.5.x No SUSE SLES 15 7.3.x No SUSE SLES 15 7.4.x No SUSE SLES 15 SP1 7.5.x Yes Ubuntu 18.4 7.3.x No Ubuntu 18.4 7.4.x Yes Ubuntu 20.04 7.5.x Yes VMware ESXi 5.5 6.7.x Yes VMware ESXi 5.5 7.1.x Yes VMware ESXi 5.5 7.2.x Yes

78 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Software iSCSI initiators (SC and SCv Series)

Operating System SC Version BfS Notes VMware ESXi 5.5 7.3.x Yes VMware ESXi 6.0 6.7.x Yes VMware ESXi 6.0 7.1.x Yes VMware ESXi 6.0 7.2.x Yes VMware ESXi 6.0 7.3.x Yes VMware ESXi 6.5 6.7.x No VMware ESXi 6.5 7.1.x No VMware ESXi 6.5 7.2.x Yes VMware ESXi 6.5 7.3.x No VMware ESXi 6.5 7.4.x No VMware ESXi 6.7 7.2.x No VMware ESXi 6.7 7.3.x No VMware ESXi 6.7 7.4.x No VMware ESXi 6.7 7.5.x No VMware ESXi 7.0 7.4.x No VMware ESXi 7.0 7.5.x No Note: Support for VMware ESXi 7.0 includes 7.0 Update 2

79 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (PS Series)

4.3.3 iSCSI converged network and host bus adapters (PS Series) Configurations listed in this section are supported at Level 1 (as described previously) for the listed switch firmware/array firmware combinations. Switch validation reflects only those switches that connect directly to the array ports. There is no validation for other upstream switches. Feature and other support levels are indicated where they differ from the default Level 1 support.

Note: Unless otherwise noted, the OS-provided native multipath IO functionality is used for all validations listed.

Vendor OS Version CNA Model Driver Boot Code Firmware Array BfS DCB Notes Vendor OS Microsoft Windows Server Broadcom BRCM570x 5.2.14.0 N/A N/A 4.0.x L1 N/A 2008 R2 Microsoft Windows Server Broadcom 6.2.7.0 N/A N/A 6.0.x L1 N/A 2008 R2 Microsoft Windows Server Broadcom 7.10.0.0 7.10.0 7.10.18 8.1.x L1 N/A 2008 R2 Microsoft Windows Server QLogic BCM577xx 5.2.11.0 N/A N/A 4.0.x L1 N/A 2008 R2 Microsoft Windows Server QLogic 7.2.5.0 N/A N/A 6.0.x L1 N/A 2008 R2 Microsoft Windows Server QLogic BCM578xx 7.2.12.0 N/A N/A 6.0.x L1 L3 2008 R2 Microsoft Windows Server QLogic 7.0.x L1 L1 2008 R2 Microsoft Windows Server QLogic 7.1.x L1 L1 2008 R2

80 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (PS Series)

Vendor OS Version CNA Model Driver Boot Code Firmware Array BfS DCB Notes Vendor OS Microsoft Windows Server QLogic BCM578xx 7.2.12.0 N/A N/A 8.x L1 L1 2008 R2 Microsoft Windows Server QLogic 7.10.0.0 7.10.0 7.10.18 8.x L1 L1 2008 R2 Microsoft Windows Server QLogic QLx405x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A 2008 R2 Microsoft Windows Server Broadcom BCM570x 7.12.0.0 7.12.1 7.12.19 9.x L1 N/A 2012 R2 Microsoft Windows Server Broadcom BCM570x 7.12.0.0 7.12.1 7.12.19 10.0.x L1 N/A 2012 R2 Microsoft Windows Server Broadcom BCM577xx 7.12.0.0 7.12.1 7.12.19 9.x L1 N/A 2012 R2 Microsoft Windows Server Broadcom BCM571xx 7.12.0.0 7.12.1 7.12.19 10.x L1 N/A 2012 R2 Microsoft Windows Server Broadcom BCM578xx 7.12.0.0 7.12.1 7.12.19 10.x L1 N/A 2012 R2 Microsoft Windows Server Broadcom BCM578xx 7.13.57.103 7.12.1 8.07.25 10.x L1 2016 Microsoft Windows Server Emulex OCx1410x 10.6.116.0 10.6.133.10 10.6.144.21 9.x L1 L1 2012 R2 Microsoft Windows Server QLogic BCM578xx 7.8.76.0 7.8.51 7.8.53 7.0.x L1 L1 HP 534 2012 R2 Microsoft Windows Server QLogic BCM578xx 7.1.x L1 L1 2012 R2 Microsoft Windows Server QLogic BCM578xx 8.x L1 L1 2012 R2

81 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (PS Series)

Vendor OS Version CNA Model Driver Boot Code Firmware Array BfS DCB Notes Vendor OS Microsoft Windows Server QLogic BCM578xx 7.10.0.0 7.10.0 7.10.18 8.1.x L1 L1 2012 R2 Microsoft Windows Server QLogic QLx82xx 2.1.5.38 2.0.1.35 2.10.37 9.x L1 L1 2012 R2 SUSE SUSE Linux Ent. Broadcom BRCM570x 2.0.4 N/A N/A 5.2.x L3 N/A SRV 11 SUSE SUSE Linux Ent. Broadcom 2.1.11 N/A N/A 6.0.x L3 N/A SRV 11 SUSE SUSE Linux Ent. Broadcom BRCM570x 2.7..10.1b 7.10.0 7.10.18 8.0 L3 N/A SRV 11 SUSE SUSE Linux Ent. Broadcom BRCM570x 2.7..10.1b 7.10.0 7.10.18 10.0.x L3 N/A SRV 11 SP3 SUSE SUSE Linux Ent. Broadcom BRCM570x 2.7..10.1b 7.10.0 7.10.18 10.0.x L3 N/A SRV 11 SP3 SUSE SUSE Linux Ent. Emulex OCx1410x 10.6.133.15 10.6.133.10 10.6.133.18 9.x L1 L1 SRV 11 SUSE SUSE Linux Ent. Emulex OCx1410x 10.6.133.15 10.6.133.10 10.6.133.18 10.x L1 L1 SRV 11 SP3 SUSE SUSE Linux Ent. QLogic BRCM577xx 2.1.11 N/A N/A 6.0.x L3 N/A SRV 11 SUSE SUSE Linux Ent. QLogic 2.7.6.2 7.10.0 7.10.18 7.0.x L1 N/A SRV 11 SUSE SUSE Linux Ent. QLogic 7.1.x L1 N/A SRV 11 SUSE SUSE Linux Ent. QLogic 7.12.19 9.x L1 L1 SRV 11

82 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (PS Series)

Vendor OS Version CNA Model Driver Boot Code Firmware Array BfS DCB Notes Vendor OS SUSE SUSE Linux Ent. QLogic BRCM578xx 1.78.00 7.12.5 7.12.19 9.x L1 L1 SRV 11 SUSE SUSE Linux Ent. QLogic BRCM578xx 2.7.10.1b 7.10.11 7.10.18 8.0 L3 N/A SRV 11 SUSE SUSE Linux Ent. QLogic BRCM578xx 2.7.6.2 7.10.0 7.10.18 8.1.x L1 L1 SRV 11 SUSE SUSE Linux Ent. QLogic BRCM578xx 7.12.5 7.12.19 9.x L1 L1 SRV 11 SUSE SUSE Linux Ent. QLogic BRCM570x 2.7.6.2 7.12.5 7.12.19 10.x L1 L1 SRV 11 SUSE SUSE Linux Ent. QLogic BRCM578x 2.7.6.2 7.12.5 7.12.19 10.x L1 L1 SRV 11 SUSE SUSE Linux Ent. QLogic QLx82xx 5.04.01.09. 2.0.1.35 2.10.37 9.x L1 L3 SRV 11 00.00-k0 SUSE SUSE Linux Ent. QLogic QLx82xx 5.04.01.09. 2.0.1.35 2.10.37 10.x L1 L3 SRV 11 SP3 00.00-k0 SUSE SUSE Linux Ent. QLogic QLx82xx 5.04.01.09. 2.0.1.35 2.10.37 10.x L1 L3 SRV 11 SP4 00.00-k0 SUSE SUSE Linux Ent. QLogic BCM578xx 2.7.6.2 7.10.0 7.10.18 8.1.x L1 L1 SRV 12 SUSE SUSE Linux Ent. QLogic 7.12.5 7.12.19 9.x L1 L1 SRV 12 SUSE SUSE Linux Ent. QLogic BCM578xx 1.712.36 7.12.5 8.07.25 10.x L1 L1 SRV 12 SUSE SUSE Linux Ent. QLogic BCM571xx 1.712.36 7.12.5 8.07.25 10.x L1 L1 SRV 12

83 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (PS Series)

Vendor OS Version CNA Model Driver Boot Code Firmware Array BfS DCB Notes Vendor OS Oracle Linux Server (UEK) QLogic BCM578xx 2.11.2.0 7.12.5 7.12.19 8.1.x L1 L3 6.6 Oracle Linux Server (UEK) QLogic 9.x L1 L3 6.6 Oracle Linux Server (UEK) QLogic BRCM570x 2.11.2.0 7.12.5 7.12.19 10.x L1 L3 6.7 Oracle Linux Server (UEK) QLogic BRCM571x 2.11.2.0 7.12.5 7.12.19 10.x L1 L3 6.7 Oracle Linux Server (UEK) QLogic BRCM578x 2.11.2.0 7.12.5 7.12.19 10.x L1 L3 6.7 Oracle Linux Server (UEK) QLogic BCM578xx 2.11.2.0 2.8.25 7.12.17 9.x L1 L3 7.0 Oracle Solaris 9-SPARC QLogic QLx405x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A Oracle Solaris 9-SPARC QLogic QLx406x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A RedHat Enterprise Linux QLogic BCM577xx 2.7.6.2 7.8.51 7.8.53 7.0.x L1 N/A 6.5 RedHat Enterprise Linux QLogic 7.1.x L1 N/A 6.5 RedHat Enterprise Linux Broadcom BRCM570x 2.7.10.1 7.10.0 7.10.18 8.1.x L1 N/A 6.6 RedHat Enterprise Linux QLogic BCM578xx 2.7.10.1 7.10.0 7.10.18 8.1.x L1 L1 6.6 RedHat Enterprise Linux QLogic BRCM570x 2.7.10.1 7.10.0 7.10.18 10.x L1 L1 6.7

84 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (PS Series)

Vendor OS Version CNA Model Driver Boot Code Firmware Array BfS DCB Notes Vendor OS RedHat Enterprise Linux QLogic BCM578xx 2.7.10.1 7.10.0 7.10.18 10.x L1 L1 6.8 RedHat Enterprise Linux QLogic BRCM570x 2.7.10.1 7.10.0 7.10.18 10.x L1 L1 6.8 RedHat Enterprise Linux QLogic BCM578xx 2.7.6.2 7.10.0 7.10.18 8.1.x L1 L1 7.0 RedHat Enterprise Linux QLogic BCM578xx 2.11.0.0 7.12.5 7.12.19 9.x L1 L1 7.0 RedHat Enterprise Linux QLogic BCM578xx 1.712.51 7.12.5 7.12.19 10.x L1 L1 7.1 RedHat Enterprise Linux QLogic BCM578xx 1.712.51 7.12.5 7.12.19 10.x L1 L1 7.3 VMware ESX/ESXi 5.5 Emulex OCe1410x 10.2.309.6 10.2.506.19 10.2.506.19 8.1.x L1 L2 VMware ESX/ESXi 5.5 QLogic BCM578xx 1.78.11v55. N/A N/A 7.0.x L3 L2 4 VMware ESX/ESXi 5.5 QLogic 7.1.x L1 N/A

VMware ESX/ESXi 5.5 QLogic QxE82xx 634.55.23.0 2.19 4.16.17 7.0.x L1 L3 -1OEM VMware ESX/ESXi 5.5 QLogic 7.1.x L1 N/A VMware ESX/ESXi 6.0 QLogic QxE82xx 634.55.23.0 2.19 4.16.17 10.x L1 N/A -1OEM VMware ESX/ESXi 6.0 Broadcom BRCM570x 2.78.76.v60 7.10.0 7.10.18 7.0.x L1 N/A .8-1 VMware ESX/ESXi 6.0 Broadcom 7.1.x L1 N/A VMware ESX/ESXi 6.0 Broadcom 8.0.x L1 N/A

85 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM iSCSI converged network and host bus adapters (PS Series)

Vendor OS Version CNA Model Driver Boot Code Firmware Array BfS DCB Notes Vendor OS VMware ESX/ESXi 6.0 Broadcom BCM578xx 2.78.76.v60 7.10.0 7.10.18 10.x L1 N/A .8-1 VMware ESX/ESXi 6.0 Emulex OCe1410x 10.2.309.6 10.2.506.19 10.2.506.19 8.1.x L1 L2 VMware ESX/ESXi 6.0 Emulex OCe1410x 10.2.309.6 10.2.506.19 10.2.506.19 10.x L1 L2 VMware ESX/ESXi 6.0 QLogic BCM578xx 2.78.76.v60 7.10.11 7.10.18 7.0.x L1 N/A .8-1 VMware ESX/ESXi 6.0 QLogic 7.1.x L1 N/A VMware ESX/ESXi 6.0 QLogic 8.0.x L1 N/A VMware ESX/ESXi 6.5 Emulex OCe1410x 10.2.309.6 10.2.506.19 10.2.506.19 10.x L1 L2 VMware ESX/ESXi 6.5 QLogic BCM578xx 2.713.10.v6 7.10.11 8.07.25 10.0.x L1 N/A 0.4

86 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Network interface cards for boot from SAN and DCB support for iSCSI (PS Series)

4.3.4 Network interface cards for boot from SAN and DCB support for iSCSI (PS Series) Network interface controllers (NIC) are the simplest class of host connectivity interfaces and provide basic Ethernet and TCP/IP functionality to the server. For storage solutions, this class of Adapters must be paired with special software within the host server operating system called a storage initiator. Dell will support any industry standards based NIC with the software iSCSI initiators listed in section 4.

The devices below have each been tested and are supported for boot from SAN functionality

Vendor OS Version NIC Vendor Model Features Notes BfS DCB Microsoft Windows Server 2008 R2 Broadcom BRCM570x L1 N/A Microsoft Windows Server 2008 R2 BRCM577xx L1 N/A Microsoft Windows Server 2008 R2 Intel i350 L1 N/A Microsoft Windows Server 2008 R2 Pro1000 L1 N/A Microsoft Windows Server 2008 R2 X5xx Family L1 L1 Microsoft Windows Server 2008 R2 QLogic BRCM578xx L1 L1 HP 534 Microsoft Windows Server 2012 Broadcom BRCM570x L1 N/A Microsoft Windows Server 2012 BRCM577xx L1 N/A Microsoft Windows Server 2012 Intel X5xx Family L1 L1 Microsoft Windows Server 2012 i350 L1 N/A Microsoft Windows Server 2012 QLogic BRCM578xx L1 L3 HP 534 Microsoft Windows Server 2012 R2 Broadcom BRCM570x L1 N/A Microsoft Windows Server 2012 R2 BRCM577xx L1 N/A Microsoft Windows Server 2012 R2 Emulex OCx1410x L1 L3 Microsoft Windows Server 2012 R2 X5xx Family L1 L1

87 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Network interface cards for boot from SAN and DCB support for iSCSI (PS Series)

Vendor OS Version NIC Vendor Model Features Notes BfS DCB Microsoft Windows Server 2012 R2 Intel i350 L1 N/A Microsoft Windows Server 2012 R2 QLogic QLx82xx L1 L3 SUSE SUSE Linux Ent. SRV 11 Broadcom BRCM570x L1 N/A SP3 SUSE SUSE Linux Ent. SRV 11 Intel X5xx Family L1 L3 SP3 SUSE SUSE Linux Ent. SRV 11 QLogic BRCM578xx L1 L3 SP3 SUSE SUSE Linux Ent. SRV 12 Broadcom BRCM570x L1 N/A SUSE SUSE Linux Ent. SRV 12 Intel X5xx Family L1 L3 SUSE SUSE Linux Ent. SRV 12 QLogic BRCM578xx L1 L3 Oracle Linux (UEK) 6.4 Broadcom BRCM570x L1 N/A Oracle Linux (UEK) 6.4 BRCM578xx L1 N/A HP 534 Oracle Linux (UEK) 6.5 BRCM570x L1 N/A Oracle Linux (UEK) 6.5 BRCM577xx L1 N/A Oracle Linux (UEK) 6.6 BRCM570x L1 N/A Oracle Linux (UEK) 6.6 QLogic BRCM578xx L1 N/A RedHat Enterprise Linux 6.4 Broadcom BRMC578xx L1 L1 HP 534 RedHat Enterprise Linux 6.5 Intel i350 L1 L3 RedHat Enterprise Linux 6.5 X5xx Family L1 L3 RedHat Enterprise Linux 7.0 Broadcom BRCM570x L1 N/A RedHat Enterprise Linux 7.0 Intel X5xx Family L1 L3 RedHat Enterprise Linux 7.0 QLogic BRCM578xx L1 N/A

88 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Network interface cards for boot from SAN and DCB support for iSCSI (PS Series)

Vendor OS Version NIC Vendor Model Features Notes BfS DCB VMware ESX/ESXi 5.5 Broadcom BRCM57xx L1 N/A VMware ESX/ESXi 5.5 BRCM577xx L1 L3 VMware ESX/ESXi 5.5 Intel X5xx Family L1 N/A VMware ESX/ESXi 5.5 QLogic BRCM578xx L1 N/A HP 534 VMware ESX/ESXi 6.0 Broadcom BRCM570x L1 N/A VMware ESX/ESXi 6.0 Intel X5xx Family L1 N/A VMware ESX/ESXi 6.0 QLogic BRCM578xx L1 N/A

89 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Software iSCSI initiators (PS Series)

4.3.5 Software iSCSI initiators (PS Series) Software iSCSI initiators are typically provided by the host OS vendor and can be used with any industry-standards-based network interface controller (NIC). The following table provides guidance on which software iSCSI initiators have been tested with each platform and the support level for advanced features, such as boot from SAN and data center bridging (DCB) functionality. It should be noted that Microsoft Windows and Red Hat Enterprise Linux provide some level of software DCB functionality, but it has not been tested by Dell and is supported on an L3 basis. If DCB is needed to allow for a converged SAN/LAN network, it is preferable that an iSCSI CNA with iSCSI Hardware Offload capability be used.

If boot from SAN functionality is desired, it is advised that the design include one of the Adapters listed in section 4 to ensure the indicated support level.

Vendor iSCSI Initiator/ Operating System Initiator Version PS Series OS Version DCB BfS Citrix XenServer 6.x 6.0.2 6.0.x N/A L3 Citrix XenServer 6.x 6.2.x 6.0.x, 7.0.x, 7.1.x N/A L3 Microsoft Windows Server 2008 R2 6.1.7600.16385 3.2.8+, 4.x, 5.x, 6.0.x N/A L1 Microsoft Windows Server 2008 R2 6.1.7601.17514 3.2.8+, 4.x, 5.x, 6.0.x, 7.0.x, 7.1.x, N/A 8.0, 8.1, 9.x L1 Microsoft Windows Server 2012 6.2.8370.0 5.2.x2, 6.0.x, 7.0.x L3 L1 Microsoft Windows Server 2012 6.2.9200.16451 6.0.x, 7.0.x, 7.1.x, 8.0, 8.1, 9.x, 10.x L3 L1 Microsoft Windows Server 2012 R2 6.3.9600.16384 6.0.x, 7.0.x, 7.1.x, 8.0.x, 8.1, 9.x, L3 L1 10.x SUSE SUSE Linux Enterprise Server 11 2.0-870 3.2.8+, 4.x, 5.x N/A L3 SUSE SUSE Linux Enterprise Server 11 2.0-873 7.0.x, 8.0.x, 8.1, 9.x, 10x. N/A L3 SUSE SUSE Linux Enterprise Server 12 2.0-873 7.0.x, 7.1.x, 8.0.x, 8.1, 9.x, 10.x N/A L3 Oracle Enterprise Linux Server 6 6 5.0.2+ N/A L3 Oracle Enterprise Linux Server 6 6.2.0-873.13.0.1 8.0, 8.1, 9.x N/A L1 Oracle Linux Server UEK 6.5 6.2.0-873.10.0.0 7.0.x, 7.1.x N/A L1

90 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Software iSCSI initiators (PS Series)

Vendor iSCSI Initiator/ Operating System Initiator Version PS Series OS Version DCB BfS Oracle Linux Server UEK 6.5 6.2.0-873.13.0.1 8.0, 8.1, 9.x N/A L1 Oracle Linux Server UEK 7.0 6.2.0.873-14 8.0, 8.1, 9.x N/A L3 RedHat Enterprise Linux Server 6 6.2.0.872-10 4.x, 5.x, 6.x N/A L1 RedHat Enterprise Linux Server 6 6.2.0.872-33 4.x, 5.x, 6.x L3 L1 RedHat Enterprise Linux Server 6 6.2.0.872-41 4.x, 5.x, 6.x L3 L1 RedHat Enterprise Linux Server 6 6.2.0.873-2 4.x, 5.x, 6.x L3 L1 RedHat Enterprise Linux Server 6 6.2.0.873-13 8.0.x, 8.1.x L3 L1 RedHat Enterprise Linux Server 7 6.2.0.873-21 7.0.x, 7.1.x, 8.0.x, 8.1, 9.x, 10.x L3 L1 VMware ESX/ESXi 5.5 In-Box 6.0.x, 7.0.x, 7.1.x, 8.1, 9.x N/A L1 VMware ESX/ESXi 6.0 In-Box 7.0.x, 7.1.x, 8.0.x, 8.1.x, 9.x, 10.x N/A L1

91 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM SAS Adapters (SC and SCv Series)

4.4 SAS Adapters (SC and SCv Series) The following table lists serial attached SCSI (SAS) HBAs that have been tested with the SC and SCv Series of array products. SAS HBAs, other than those listed below, are NOT supported by Dell at this time. Boot from SAN (BfS) is not supported.

Note: Windows Storage Server 2012 and higher follow the same characteristics and support of Windows Server 2012 and higher.

Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes Microsoft 2008 Windows Dell 12G SAS Adapter 2.50.75.01 03.00.08.00 6.7.x Not Server R2 SP1 Supported Microsoft 2008 Windows Dell 12G SAS Adapter 2.50.92.0 09.00.09.00-IT 7.1.x Not Dell fw kit: Server R2 SP1 Supported 9.17.20.07,A01 Microsoft 2008 Windows Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.2.x Not Dell fw kit: Server R2 SP1 Supported 13.17.03.00_A03 Microsoft 2008 Windows Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.3.x Not Dell fw kit: Server R2 SP1 Supported 13.17.03.00_A03 Microsoft 2008 Windows Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.1.x Not Dell fw kit: Server R2 SP1 Supported 9.17.20.07,A01 Microsoft 2008 Windows Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.2.x Not Dell fw kit: Server R2 SP1 Supported 9.17.20.07,A01 Microsoft 2008 Windows LSI 9300-8e 2.50.80.0 03.00.08.00 7.2.x Not Server R2 SP1 Supported Microsoft 2008 Windows LSI 9300-8e 2.50.80.0 13.00.00.00-IT 7.2.x Not Server R2 SP1 Supported Microsoft 2008 Windows LSI 9300-8e 2.50.80.0 13.00.00.00-IT 7.3.x Not Server R2 SP1 Supported Microsoft 2008 Windows LSI 9300-8e 2.50.80.0 15.00.00.00-IT 7.2.x Not Server R2 SP1 Supported Microsoft 2008 Windows LSI 9300-8e 2.50.80.0 15.00.00.00-IT 7.4.x Not Server R2 SP1 Supported Microsoft 2012 Windows Dell 12G SAS Adapter 2.50.75.01 03.00.08.00 6.7.x Not Server Supported Microsoft 2012 Windows Dell 12G SAS Adapter 2.50.75.01 09.00.09.00-IT 7.1.x Not Dell fw kit: Server Supported 9.17.20.07,A01

92 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM SAS Adapters (SC and SCv Series)

Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.2.x Not Dell fw kit: Server Supported 13.17.03.00_A03 Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.3.x Not Dell fw kit: Server Supported 13.17.03.00_A03 Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.1.x Not Dell fw kit: Server Supported 9.17.20.07,A01 Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.2.x Not Dell fw kit: Server Supported 9.17.20.07,A01 Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.15.0 15.17.09.06 7.3.x Not Dell fw kit: Server Supported 15.17.09.06_A07 Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.15.0 16.17.00.03 7.4.x Not Server Supported Microsoft 2012 Windows Dell 12G SAS Adapter 2.50.75.01 03.00.08.00 6.7.x Not Server R2 Supported Microsoft 2012 Windows Dell 12G SAS Adapter 2.50.75.01 09.00.09.00-IT 7.1.x Not Dell fw kit: Server R2 Supported 9.17.20.07,A01 Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.2.x Not Dell fw kit: Server R2 Supported 13.17.03.00_A03 Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.1.2 13.00.00.00-IT 7.3.x Not Dell fw kit: Server R2 Supported 13.17.03.00_A03 Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.1.x Not Dell fw kit: Server R2 Supported 9.17.20.07,A01 Microsoft 2012 Windows Dell 12G SAS Adapter 2.51.1.2 09.00.09.00-IT 7.2.x Not Dell fw kit: Server R2 Supported 9.17.20.07,A01 Microsoft 2012 Windows LSI 9300-8e 2.50.80.1 03.00.08.00 7.2.x Not Server R2 Supported Microsoft 2012 Windows LSI 9300-8e 2.50.80.1 13.00.00.00-IT 7.2.x Not Server R2 Supported Microsoft 2012 Windows LSI 9300-8e 2.50.80.1 13.00.00.00-IT 7.3.x Not Server R2 Supported Microsoft 2012 Windows LSI 9300-8e 2.50.80.1 15.00.00.00-IT 7.2.x Not Server R2 Supported Microsoft 2012 Windows LSI 9300-8e 2.50.80.1 15.00.00.00-IT 7.4.x Not Server R2 Supported

93 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM SAS Adapters (SC and SCv Series)

Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes Microsoft 2012 Windows LSI 9300-8e 2.50.80.1 17.00.10.00 7.5.x Not Server R2 Supported Microsoft 2016 Windows Dell 12G SAS Adapter 2.51.15.0 13.00.00.00-IT 7.1.x Not Dell fw kit: Server Supported 13.17.03.00_A03 Microsoft 2016 Windows Dell 12G SAS Adapter 2.51.15.0 13.00.00.00-IT 7.2.x Not Dell fw kit: Server Supported 13.17.03.00_A03 Microsoft 2016 Windows Dell 12G SAS Adapter 2.51.15.0 13.00.00.00-IT 7.3.x Not Dell fw kit: Server Supported 13.17.03.00_A03 Microsoft 2016 Windows Dell 12G SAS Adapter 2.51.21.1 15.17.09.06 7.3.x Not Dell fw kit: Server Supported 15.17.09.06_A07 Microsoft 2016 Windows Dell 12G SAS Adapter 2.51.25.1 16.17.00.03 7.4.x Not Server Supported Microsoft 2016 Windows Dell 12G SAS Adapter 2.51.25.1 16.17.01.00 7.5.x Not Server Supported Microsoft 2016 Windows LSI 9300-8e 2.51.12.80 03.00.08.00 7.2.x Not Server Supported Microsoft 2016 Windows LSI 9300-8e 2.51.12.80 13.00.00.00-IT 7.2.x Not Server Supported Microsoft 2016 Windows LSI 9300-8e 2.51.12.80 13.00.00.00-IT 7.3.x Not Server Supported Microsoft 2016 Windows LSI 9300-8e 2.51.12.80 15.00.00.00-IT 7.2.x Not Server Supported Microsoft 2016 Windows LSI 9300-8e 2.51.12.80 15.00.00.00-IT 7.4.x Not Server Supported Microsoft 2016 Windows LSI 9300-8e 2.51.12.80 17.00.10.00 7.5.x Not Server Supported Microsoft 2019 Windows Dell 12G SAS Adapter 2.51.24.80 16.17.00.03 7.3.x Not Server Supported Microsoft 2019 Windows Dell 12G SAS Adapter 2.51.24.80 16.17.00.03 7.4.x Not Server Supported Microsoft 2019 Windows Dell 12G SAS Adapter 2.51.24.80 16.17.00.03 7.5.x Not Server Supported Red Hat RHEL 6.x Dell 12G SAS Adapter 04.100.00.00-rh 13.00.00.00-IT 7.2.x Not Dell fw kit: Supported 13.17.03.00_A03

94 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM SAS Adapters (SC and SCv Series)

Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes Red Hat RHEL 6.x Dell 12G SAS Adapter 04.100.00.00-rh 09.00.09.00-IT 7.1.x Not Dell fw kit: Supported 9.17.20.07,A01 Red Hat RHEL 6.x Dell 12G SAS Adapter 04.100.00.00-rh 09.00.09.00-IT 7.2.x Not Dell fw kit: Supported 9.17.20.07,A01 Red Hat RHEL 6.x Dell 12G SAS Adapter 14.101.00.00-rh 13.00.00.00-IT 7.2.x Not Dell fw kit: Supported 13.17.03.00_A03 Red Hat RHEL 6.x Dell 12G SAS Adapter 14.101.00.00-rh 13.00.00.00-IT 7.3.x Not Dell fw kit: Supported 13.17.03.00_A03 Red Hat RHEL 6.x Dell 12G SAS Adapter OS Built-In 03.00.08.00 6.7.x Not Supported Red Hat RHEL 6.x Dell 12G SAS Adapter 22.00.04.00 15.17.09.06 7.3.x Not Dell fw kit: Supported 15.17.09.06_A07 Red Hat RHEL 6.x Dell 12G SAS Adapter 27.00.01.00 15.17.09.06 7.3.x Not Dell fw kit: Supported 15.17.09.06_A07 Red Hat RHEL 6.x Dell 12G SAS Adapter 27.00.01.00 16.17.00.03 7.4.x Not Supported Red Hat RHEL 6.x LSI 9300-8e 09.102.00.00-rh 03.00.08.00 7.2.x Not Supported Red Hat RHEL 6.x LSI 9300-8e 09.102.00.00-rh 13.00.00.00-IT 7.2.x Not Supported Red Hat RHEL 6.x LSI 9300-8e 09.102.00.00-rh 13.00.00.00-IT 7.3.x Not Supported Red Hat RHEL 6.x LSI 9300-8e 09.102.00.00-rh 15.00.00.00-IT 7.2.x Not Supported Red Hat RHEL 6.x LSI 9300-8e 14.101.00.00-rh 13.00.00.00-IT 7.3.x Not Supported Red Hat RHEL 6.x LSI 9300-8e 14.101.00.00-rh 15.00.00.00-IT 7.4.x Not Supported Red Hat RHEL 7.x Dell 12G SAS Adapter 04.100.00.00-rh 13.00.00.00-IT 7.2.x Not Dell fw kit: Supported 13.17.03.00_A03 Red Hat RHEL 7.x Dell 12G SAS Adapter 04.100.00.00-rh 09.00.09.00-IT 7.1.x Not Dell fw kit: Supported 9.17.20.07,A01 Red Hat RHEL 7.x Dell 12G SAS Adapter 04.100.00.00-rh 09.00.09.00-IT 7.2.x Not Dell fw kit: Supported 9.17.20.07,A01

95 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM SAS Adapters (SC and SCv Series)

Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes Red Hat RHEL 7.x Dell 12G SAS Adapter 15.100.00.00 13.00.00.00-IT 7.2.x Not Dell fw kit: Supported 13.17.03.00_A03 Red Hat RHEL 7.x Dell 12G SAS Adapter 15.100.00.00 13.00.00.00-IT 7.3.x Not Dell fw kit: Supported 13.17.03.00_A03 Red Hat RHEL 7.x Dell 12G SAS Adapter OS Built-In 03.00.08.00 6.7.x Not Supported Red Hat RHEL 7.x Dell 12G SAS Adapter 16.100.00.00 15.17.09.06 7.3.x Not Dell fw kit: Supported 15.17.09.06_A07 Red Hat RHEL 7.x Dell 12G SAS Adapter 16.100.00.00 16.17.00.03 7.4.x Not Supported Red Hat RHEL 7.x Dell 12G SAS Adapter 27.00.01.00 15.17.09.06 7.3.x Not Dell fw kit: Supported 15.17.09.06_A07 Red Hat RHEL 7.x LSI 9300-8e 13.100.00.00-rh 03.00.08.00 7.2.x Not Supported Red Hat RHEL 7.x LSI 9300-8e 13.100.00.00-rh 13.00.00.00-IT 7.2.x Not Supported Red Hat RHEL 7.x LSI 9300-8e 13.100.00.00-rh 13.00.00.00-IT 7.3.x Not Supported Red Hat RHEL 7.x LSI 9300-8e 13.100.00.00-rh 15.00.00.00-IT 7.2.x Not Supported Red Hat RHEL 7.x LSI 9300-8e 16.100.00.00 13.00.00.00-IT 7.3.x Not Supported Red Hat RHEL 7.x LSI 9300-8e 16.100.00.00 15.00.00.00-IT 7.4.x Not Supported Red Hat RHEL 7.x Dell 12G SAS Adapter 16.00.11.00 18.00.03.00 7.5.x Not Supported Red Hat RHEL 7.x LSI 9300-8e 16.100.00.00 15.00.00.00-IT 7.5.x Not Supported Red Hat RHEL 8.x Dell 12G SAS Adapter 32.100.00.00 16.17.01.00 7.5.x Not Supported Red Hat RHEL 8.x LSI 9300-8e 32.100.00.00 17.00.10.00 7.5.x Not Supported VMware ESXi 5.5 Dell 12G SAS Adapter mpt3sas 03.00.08.00 6.7.x Not Dell fw kit: 04.00.00.00.1vmw Supported 13.17.03.00_A03

96 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM SAS Adapters (SC and SCv Series)

Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes VMware ESXi 5.5 Dell 12G SAS Adapter mpt3sas 13.00.00.00-IT 7.2.x Not Dell fw kit: 10.00.02.00 - 5.5 Supported 9.17.20.07,A01 VMware ESXi 5.5 Dell 12G SAS Adapter mpt3sas 09.00.09.00-IT 6.7.x Not Dell fw kit: 10.00.02.00 - 5.5 Supported 9.17.20.07,A01 VMware ESXi 5.5 Dell 12G SAS Adapter mpt3sas 09.00.09.00-IT 7.1.x Not Dell fw kit: 10.00.02.00 - 5.5 Supported 9.17.20.07,A01 VMware ESXi 5.5 Dell 12G SAS Adapter mpt3sas 09.00.09.00-IT 7.2.x Not Dell fw kit: 10.00.02.00 - 5.5 Supported 13.17.03.00_A03 VMware ESXi 5.5 Dell 12G SAS Adapter mpt3sas 13.00.00.00-IT 7.2.x Not Dell fw kit: 13.00.00.00 Supported 13.17.03.00_A03 VMware ESXi 5.5 Dell 12G SAS Adapter mpt3sas 13.00.00.00-IT 7.3.x Not 13.00.00.00 Supported VMware ESXi 5.5 LSI 9300-8e mpt3sas 03.00.08.00 7.2.x Not 04.00.00.00.1vmw Supported VMware ESXi 5.5 LSI 9300-8e mpt3sas 13.00.00.00-IT 7.2.x Not 04.00.00.00.1vmw Supported VMware ESXi 5.5 LSI 9300-8e mpt3sas 13.00.00.00-IT 7.3.x Not 04.00.00.00.1vmw Supported VMware ESXi 6.0 Dell 12G SAS Adapter mpt3sas 03.00.08.00 6.7.x Not Dell fw kit: 04.00.00.00.1vmw Supported 13.17.03.00_A03 VMware ESXi 6.0 Dell 12G SAS Adapter mpt3sas 13.00.00.00-IT 7.2.x Not Dell fw kit: 10.00.02.00 - 6.0 Supported 9.17.20.07,A01 VMware ESXi 6.0 Dell 12G SAS Adapter mpt3sas 09.00.09.00-IT 6.7.x Not Dell fw kit: 10.00.02.00 - 6.0 Supported 9.17.20.07,A01 VMware ESXi 6.0 Dell 12G SAS Adapter mpt3sas 09.00.09.00-IT 7.1.x Not Dell fw kit: 10.00.02.00 - 6.0 Supported 9.17.20.07,A01 VMware ESXi 6.0 Dell 12G SAS Adapter mpt3sas 09.00.09.00-IT 7.2.x Not Dell fw kit: 10.00.02.00 - 6.0 Supported 13.17.03.00_A03 VMware ESXi 6.0 Dell 12G SAS Adapter mpt3sas 13.00.00.00-IT 7.2.x Not Dell fw kit: 13.00.00.00 Supported 13.17.03.00_A03 VMware ESXi 6.0 Dell 12G SAS Adapter mpt3sas 13.00.00.00-IT 7.3.x Not 13.00.00.00 Supported lsi_msgpt3 16.00.01.00- Not VMware ESXi 6.0 Dell 12G SAS Adapter 1vmw 15.17.09.06 7.3.x Supported

97 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM SAS Adapters (SC and SCv Series)

Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes lsi_msgpt3 16.00.01.00- Not VMware ESXi 6.0 Dell 12G SAS Adapter 1vmw 16.17.00.03 7.4.x Supported mpt3sas Not VMware ESXi 6.0 LSI 9300-8e 04.00.00.00.1vmw 03.00.08.00 7.2.x Supported mpt3sas Not VMware ESXi 6.0 LSI 9300-8e 04.00.00.00.1vmw 13.00.00.00-IT 7.2.x Supported mpt3sas Not VMware ESXi 6.0 LSI 9300-8e 04.00.00.00.1vmw 13.00.00.00-IT 7.3.x Supported mpt3sas Not Dell fw kit: VMware ESXi 6.0 LSI 9300-8e 04.00.00.00.1vmw 15.00.00.00-IT 7.4.x Supported 13.17.03.00_A03 lsi_msgpt3 12.00.02.00- Not Dell fw kit: VMware ESXi 6.5 Dell 12G SAS Adapter 11vmw 13.00.00.00-IT 7.2.x Supported 13.17.03.00_A03 lsi_msgpt3 12.00.02.00- Not VMware ESXi 6.5 Dell 12G SAS Adapter 11vmw 13.00.00.00-IT 7.3.x Supported lsi_msgpt3 16.00.01.00- Not VMware ESXi 6.5 Dell 12G SAS Adapter 1vmw 15.17.09.06 7.3.x Supported lsi_msgpt3 16.00.01.00- Not VMware ESXi 6.5 Dell 12G SAS Adapter 1vmw 16.17.00.03 7.4.x Supported lsi_msgpt3 12.00.02.00- Not VMware ESXi 6.5 LSI 9300-8e 11vmw 03.00.08.00 7.2.x Supported lsi_msgpt3 12.00.02.00- Not VMware ESXi 6.5 LSI 9300-8e 11vmw 13.00.00.00-IT 7.2.x Supported lsi_msgpt3 12.00.02.00- Not VMware ESXi 6.5 LSI 9300-8e 11vmw 13.00.00.00-IT 7.3.x Supported lsi_msgpt3 12.00.02.00- Not VMware ESXi 6.5 LSI 9300-8e 11vmw 15.00.00.00-IT 7.4.x Supported

98 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM SAS Adapters (SC and SCv Series)

Operating System SAS Host Adapter Driver Firmware SC Version BfS Notes lsi_msgpt3 16.00.01.00- Not VMware ESXi 6.7 Dell 12G SAS Adapter 3vmw 15.17.09.06 7.3.x Supported lsi_msgpt3 16.00.01.00- Not VMware ESXi 6.7 Dell 12G SAS Adapter 3vmw 16.17.00.03 7.4.x Supported LSI 9300-8e lsi_msgpt3 17.00.10.00 7.5.x Not 17.00.02.00- Supported VMware ESXi 6.7 1vmw lsi_msgpt3 17.00.10.00- Not VMware ESXi 7.0 Dell 12G SAS Adapter 1vmw 16.17.00.05 7.4.x Supported lsi_msgpt3 17.00.02.00- Not VMware ESXi 7.0 LSI 9300-8e 1vmw 13.00.00.00 7.4.x Supported lsi_msgpt3 17.00.10.00- Not VMware ESXi 7.0 LSI 9300-8e 1vmw 13.00.00.00 7.5.x Supported Note: Support for VMware ESXi 7.0 includes 7.0 Update 2

* Adapter only supported in Dell PowerEdge 13th Generation and above server products

99 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)

4.5 Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)

4.5.1 FCoE converged network and host bus adapters (SC, SCv Series)

Operating System FCoE Host Adapter Driver BootCode Firmware SC Version BfS Notes Microsoft 2008 Windows Cisco VIC-12xx 2.1.0.29 2.2(4b) 2.2(4b) 6.7.x Yes Server R2 SP1 Microsoft 2008 Windows QLogic QxE826x 9.1.12.10 3.28 4.18.04 6.7.x Yes Dell fw kit: 2.10.29 Server R2 SP1 Microsoft 2008 Windows QLogic QxE826x 9.1.13.10 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37 Server R2 SP1 Microsoft 2008 Windows QLogic QxE826x 9.1.13.10 3.31 4.18.04 6.7.x Yes Dell fw kit: 02.10.38 Server R2 SP1 Microsoft 2008 Windows QLogic QxE826x 9.1.13.10 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38 Server R2 SP1 Microsoft 2008 Windows QLogic QxE826x 9.1.13.10 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38 Server R2 SP1 Microsoft 2008 Windows QLogic QxE826x 9.1.13.10 3.44 4.20.21 7.2.x Yes Dell fw kit: 09.00.03 Server R2 SP1 Microsoft 2008 Windows QLogic QxE826x 9.1.13.10 3.44 4.20.21 7.3.x Yes Dell fw kit: 09.00.03 Server R2 SP1 Microsoft 2012 Windows Cisco VIC-12xx 2.4.0.9 2.2(4b) 2.2(4b) 6.7.x Yes Server R2 Microsoft 2012 Windows Emulex OCx1410x 10.6.114.0 10.6.133.18 10.6.133.18 6.7.x Yes Server R2 Microsoft 2012 Windows Emulex OCx1410x 11.0.247.0 11.0.270.15 11.0.270.15 7.1.x Yes Dell fw kit: 02.00.01 Server R2 Microsoft 2012 Windows Emulex OCx1410x 11.0.247.0 11.0.270.4 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04 Server R2 Microsoft 2012 Windows Emulex OCx1410x 11.0.247.0 11.0.270.4 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04 Server R2 Microsoft 2012 Windows Emulex OCx1410x 11.2.1135.0 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01 Server R2

100 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)

Operating System FCoE Host Adapter Driver BootCode Firmware SC Version BfS Notes Microsoft 2012 Windows Emulex OCx1410x 11.2.1135.0 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01 Server R2 Microsoft 2012 Windows QLogic QxE826x 9.1.12.10 3.28 4.18.04 6.7.x Yes Dell fw kit: 2.10.29 Server R2 Microsoft 2012 Windows QLogic QxE826x 9.1.13.10 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37 Server R2 Microsoft 2012 Windows QLogic QxE826x 9.1.13.10 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38 Server R2 Microsoft 2012 Windows QLogic QxE826x 9.1.13.10 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38 Server R2 Microsoft 2012 Windows QLogic QxE826x 9.1.13.10 3.44 4.20.21 7.2.x Yes Dell fw kit: 09.00.03 Server R2 Microsoft 2012 Windows QLogic QxE826x 9.1.13.10 3.44 4.20.21 7.3.x Yes Dell fw kit: 09.00.03 Server R2 Microsoft 2012 Windows Broadcom 578xx 7.12.1.0 7.12.4 7.12.17 6.7.x Yes Server R2 Microsoft 2012 Windows Broadcom 578xx 7.12.42.0 7.12.4 7.12.19 7.1.x Yes Server R2 Microsoft 2012 Windows Broadcom 578xx 7.14.14.0 7.15.0 10.01.00 7.2.x Yes Server R2 Microsoft 2012 Windows Broadcom 578xx 7.14.14.0 7.15.0 10.01.00 7.3.x Yes Server R2 Microsoft 2012 Windows Broadcom 578xx 7.14.3.0 7.13.60.0 7.13.60.0 6.7.x Yes Dell fw kit: 08.07.25 Server R2 Microsoft 2012 Windows Broadcom 578xx 7.14.3.0 7.13.60.0 7.13.60.0 7.1.x Yes Dell fw kit: 08.07.25 Server R2 Microsoft 2012 Windows Broadcom 578xx 7.14.3.0 7.13.60.0 7.13.60.0 7.2.x Yes Dell fw kit: 08.07.25 Server R2 Microsoft 2016 Windows QLogic QL41xxx 8.24.3 - 14.07.05 7.3.x No Server Microsoft 2016 Windows QLogic QL41xxx 8.24.3 - 14.07.07 7.1.x No Server Microsoft 2016 Windows QLogic QL41xxx 8.24.3 - 14.07.07 7.3.x No Server

101 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)

Operating System FCoE Host Adapter Driver BootCode Firmware SC Version BfS Notes Microsoft 2016 Windows QLogic QL41xxx 8.24.3 - 14.07.07 7.4.x No Server Microsoft 2016 Windows QLogic QL41xxx 8.55.3.0 - 14.07.07 7.5.x No Server Red Hat RHEL 7.x Cisco VIC-12xx 1.6.0.18 2.2(4b) 2.2(4b) 6.7.x Yes VMware ESXi 5.5 Cisco VIC-12xx 1.6.0.17a 2.2(4b) 2.2(4b) 6.7.x Yes VMware ESXi 5.5 Emulex OCx1410x 10.6.126.0 10.6.133.18 10.6.133.18 6.7.x Yes Dell fw kit: 01.06.01 VMware ESXi 5.5 Emulex OCx1410x 10.6.126.0 11.0.270.4 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04 VMware ESXi 5.5 Emulex OCx1410x 11.0.237.0 10.6.133.18 10.6.133.18 7.1.x Yes Dell fw kit: 01.06.01 VMware ESXi 5.5 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2007 6.7.x Yes Dell fw kit: 02.00.04 VMware ESXi 5.5 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04 VMware ESXi 5.5 Emulex OCx1410x 11.1.145.18 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 5.5 Emulex OCx1410x 11.1.145.18 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 5.5 QLogic QxE826x 1.1.55.0 3.28 4.18.04 6.7.x Yes Dell fw kit: 2.10.29 VMware ESXi 5.5 QLogic QxE826x 1.1.55.0 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37 VMware ESXi 5.5 QLogic QxE826x 1.1.55.0 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38 VMware ESXi 5.5 QLogic QxE826x 1.1.70.0 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37 VMware ESXi 5.5 QLogic QxE826x 1.1.70.0 3.31 4.18.04 6.7.x Yes Dell fw kit: 02.10.38 VMware ESXi 5.5 QLogic QxE826x 1.1.70.0 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38 VMware ESXi 5.5 QLogic QxE826x 1.1.70.0 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38 VMware ESXi 5.5 QLogic QxE826x 1.1.70.0 3.44 4.20.21 7.2.x Yes Dell fw kit: 09.00.03 VMware ESXi 5.5 QLogic QxE826x 1.1.70.0 3.44 4.20.21 7.3.x Yes Dell fw kit: 09.00.03 VMware ESXi 5.5 Broadcom 578xx 1.712.30.v55.2 7.12.4 7.12.17 6.7.x Yes VMware ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.4 08.07.25 6.7.x Yes VMware ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.4 08.07.25 7.1.x Yes VMware ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.4 08.07.25 7.2.x Yes VMware ESXi 5.5 Broadcom 578xx 1.712.70.v55.5 7.12.5 7.12.19 7.1.x Yes VMware ESXi 5.5 Broadcom 578xx 1.713.10.v55.4 7.15.0 10.01.00 7.2.x Yes Dell fw kit: 10.01.00 VMware ESXi 5.5 Broadcom 578xx 1.713.10.v55.4 7.15.0 10.01.00 7.3.x Yes Dell fw kit: 10.01.00 VMware ESXi 6.0 Emulex OCx1410x 10.6.126.0 10.6.133.18 10.6.133.18 7.1.x Yes Dell fw kit: 01.06.01 VMware ESXi 6.0 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2002 7.1.x Yes Dell fw kit: 02.00.04

102 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)

Operating System FCoE Host Adapter Driver BootCode Firmware SC Version BfS Notes VMware ESXi 6.0 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2007 7.1.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.0 Emulex OCx1410x 11.1.145.18 11.0.270.4 11.0.270.2007 7.2.x Yes Dell fw kit: 02.00.04 VMware ESXi 6.0 Emulex OCx1410x 11.2.156.20 11.2.1197.13 11.2.1197.13 7.2.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.0 Emulex OCx1410x 11.4.142.11 11.2.1197.13 11.2.1197.13 7.3.x Yes Dell fw kit: 02.01.01 VMware ESXi 6.0 QLogic QxE826x 2.1.20.0 3.28 4.18.04 6.7.x Yes Dell fw kit: 2.10.29 VMware ESXi 6.0 QLogic QxE826x 2.1.24.0 3.29 4.18.04 7.1.x Yes Dell fw kit: 02.10.37 VMware ESXi 6.0 QLogic QxE826x 2.1.24.0 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38 VMware ESXi 6.0 QLogic QxE826x 2.1.24.0 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38 VMware ESXi 6.0 QLogic QxE826x 2.1.43.0 3.31 4.18.04 6.7.x Yes Dell fw kit: 02.10.38 VMware ESXi 6.0 QLogic QxE826x 2.1.43.0 3.31 4.18.04 7.1.x Yes Dell fw kit: 02.10.38 VMware ESXi 6.0 QLogic QxE826x 2.1.43.0 3.31 4.18.04 7.2.x Yes Dell fw kit: 02.10.38 VMware ESXi 6.0 QLogic QxE826x 2.1.50.0 3.44 4.20.21 7.2.x Yes Dell fw kit: 09.00.03 VMware ESXi 6.0 QLogic QxE826x 2.1.57.0 3.44 4.20.21 7.3.x Yes Dell fw kit: 09.00.03 VMware ESXi 6.0 Broadcom 578xx 1.712.10.v55.2 - N/A 7.1.x No Dell fw kit: 08.07.25 VMware ESXi 6.0 Broadcom 578xx 1.712.10.v55.2 - N/A 7.2.x No Dell fw kit: 08.07.25 VMware ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - 08.07.25 7.1.x No VMware ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - 08.07.25 7.2.x No VMware ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - N/A 6.7.x No Dell fw kit: 7.12.17 VMware ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - 7.12.4 6.7.x No Dell fw kit: 7.12.17 VMware ESXi 6.0 Broadcom 578xx 1.712.30.v55.2 - 7.12.4 7.1.x No Dell fw kit: 7.12.19 VMware ESXi 6.0 Broadcom 578xx 1.712.70.v55.5 - N/A 6.7.x No Dell fw kit: 08.07.25 VMware ESXi 6.0 Broadcom 578xx 1.712.70.v55.5 - N/A 7.1.x No Dell fw kit: 08.07.25 VMware ESXi 6.0 Broadcom 578xx 1.712.70.v55.5 - N/A 7.2.x No Dell fw kit: 08.07.25 VMware ESXi 6.0 Broadcom 578xx 1.713.10.v60.4 - 08.07.25 7.1.x No VMware ESXi 6.0 Broadcom 578xx 1.713.10.v60.4 - 08.07.25 7.2.x No VMware ESXi 6.0 Broadcom 578xx 1.713.30.v60.3 - 10.01.00 7.2.x No Dell fw kit: 10.01.00 VMware ESXi 6.0 Broadcom 578xx 1.713.30.v60.3 - 10.01.00 7.3.x No Dell fw kit: 10.01.00 VMware ESXi 6.0 Broadcom 578xx 1.713.30.v60.6 - 10.01.00 7.3.x No Dell fw kit: 10.01.00 VMware ESXi 6.5 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.3.x No VMware ESXi 6.5 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.4.x No

103 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)

Operating System FCoE Host Adapter Driver BootCode Firmware SC Version BfS Notes VMware ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.3.x No VMware ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.50 7.3.x No VMware ESXi 6.7 QLogic QL41xxx 1.2.24.6 - 14.07.07 7.4.x No VMware ESXi 6.7 QLogic QL41xxx 2.2.9.0 15.15.11 15.15.11 7.5.x No VMware ESXi 7.0 QLogic QL41xxx 2.2.8.0 15.15.11 15.15.11 7.5.x No Note: Support for VMware ESXi 7.0 includes 7.0 Update 2

104 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Fibre Channel over Ethernet (FCoE) Adapters (SC, SCv Series)

4.5.2 Software FCoE initiators (SC and SCv Series) Software FCoE initiators may be provided by the host OS vendor and can be used with any industry-standards-based network interface controller (NIC) that supports software-based FCoE. The following table provides guidance on which software FCoE initiators have been tested with each platform and the support level for advanced features, such as boot from SAN.

If boot from SAN functionality is desired, it is advised that the design include one of the Adapters listed ensure the indicated support level. Always verify OS support by SC Series product.

Operating System SC Version BfS Notes VMware ESXi 5.5 6.7.x No VMware ESXi 5.5 7.1.x No VMware ESXi 5.5 7.2.x No VMware ESXi 5.5 7.3.x No VMware ESXi 6.0 6.7.x No VMware ESXi 6.0 7.1.x No VMware ESXi 6.0 7.2.x No VMware ESXi 6.0 7.3.x No VMware ESXi 6.5 7.3.x No VMware ESXi 6.5 7.4.x No VMware ESXi 6.7 7.3.x No VMware ESXi 6.7 7.4.x No

105 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Other support matrices

5 Other support matrices

5.1 Cisco UCS support In cooperation with Cisco, Dell is now certified for certain UCS configurations. UCS certifications can be found in the Cisco UCS Interoperability Matrix.

5.2 Storage virtualization appliances Dell does not directly test or validate third-party storage virtualization appliances in front of Dell storage products. Dell does work with various third-party vendors of such appliances to ensure that our arrays have been validated with these vendor’s devices and to ensure that our storage products are listed in each vendor’s respective certification matrices. Please reference the vendor specific sites to verify product interoperability support.

5.3 KMS solutions SC Series supports 3rd party external key management with Thales.

Vendor KMS solution KMS version SCOS version Thales Physical Appliance 1.9.x 7.3.20 CipherTrust Key - K470 7.4.10 Manager - K570 Virtual Appliance - K170v 1.10.x 7.5.x - K470v 2.0.x 7.5.x Thales KeySecure Virtual Appliance -K150v 8.0.x 6.5.x, 6.6.x, 6.7.x, 7.1.x (formally Gemalto- SafeNet).

Now EOL and not recommended for new designs.

8.5.0, 8.7.x, 8.10.x 6.5.x, 6.6.x, 6.7.x, 7.1.x, 7.3.x, 7.4.x, 7.5.x

Physical Appliance - K250, 6.6.x 6.5.x, 6.6.x, 6.7.x, 7.1.x without HSM 8.1.x, 8.7.x, 8.10.x 6.5.x, 6.6.x, 6.7.x, 7.1.x, 7.3.x, 7.4.x, 7.5.x

Physical Appliance - K460, 6.6.x 6.5.x, 6.6.x, 6.7.x, 7.1.x with HSM 8.7.x, 8.10.x 6.5.x, 6.6.x, 6.7.x, 7.1.x, 7.3.x, 7.4.x, 7.5.x

106 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Other support matrices

5.4 Data Protection SC Series snapshot integration support with 3rd party data protection solutions.

Vendor Software Version Plug-in Version SCOS version CommVault Simpana 11 SP13 CVSE 3.2 7.3.x, 7.4.x

Veeam 9.5 u4A, u4B, 10.0 P1 1.0.210 7.4.x, 7.5.x

107 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A Required Adapter and Server OS Settings

Server host bus adapters and converged network adapters (hereafter called adapters) require specific configuration settings in order to maintain IO during Storage Center controller failovers and network/fabric path failovers. Some of these settings are identical for all supported operating systems and others vary by operating system. The information below identifies adapter settings that are identical for all supported operating systems. If the adapter is not listed below, default settings are acceptable.

A.1 Adapter Settings

A.1.1 Cisco Fibre Channel Adapters

Field Setting

Flogi Retries 60

Plogi Retries 60

A.1.2 Emulex Fibre Channel Adapters

Field Settings

Topology LPe16xxx and earlier: 1 (point to point)

VMware ESXi: Set topology to 2 for Auto Topology (point to point first)

LPe31xxx and later: N/A, value does not exist

NodeTimeOut Node Time Out field, lpfc_devloss_tmo 60 (formerly nodev_tmo)

108 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.1.3 QLogic Fibre Channel Adapters (and re-branded adapters based on QLogic)

Field Settings

Connection option QLe25xx and earlier: 1 (point-to-point)

QLe26xx and later: Default

Login retry count 60

Port down retry count 60

Link down timeout 30

109 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2 Server OS Settings

A.2.1 Windows Server 2008r2

A.2.1.1 Recommended updates and hotfixes for Windows Server 2008r2

See the Microsoft Update Catalog at https://www.catalog.update.microsoft.com/Home.aspx to locate specific KB downloads.

KB number Title

KB3125574 Convenience rollup update for Windows 7 SP1 and Windows Server 2008 R2 SP1 (May 2016) msdsm.sys version 6.1.7601.23403 (3/25/16) mpio.sys version 6.1.7601.23403 (3/25/16) msiscsi.sys version 6.1.7601.23403 (3/25/16) storport.sys version 6.1.7601.23403 (3/25/16)

A.2.1.2 Recommended MPIO registry settings for Windows Server 2008r2

The recommend registry settings listed in this section can be applied using the registry editor (regedit.exe) or through PowerShell. The registry editor can be used on all versions of Windows Server Desktop (Windows Server with a GUI).

MPIO Registry Settings: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters Default Recommended Setting name Description value value PDORemovePeriod This setting controls the number 20 120 of seconds that the multipath pseudo-LUN remains in system memory, even after losing all paths to the device. When this timer value is exceeded, pending I/O operations will be failed, and the failure is exposed to the application rather than attempting to continue to recover active paths. The maximum time allowed is MAXULONG (49,000 seconds). PathRecoveryInterval This represents the period after 40 25 which PathRecovery is attempted. This setting is only used if it is not set to 0 and UseCustomPathRecoveryInterval is set to 1.

110 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

MPIO Registry Settings: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters Default Recommended Setting name Description value value UseCustomPathRecoveryInterval If this key exists and is set to 1, it 0 1 allows the use of PathRecoveryInterval. PathVerifyEnabled This flag enables path verification 0 1 by MPIO on all paths every N seconds (where N depends on the value set in PathVerificationPeriod).

This Boolean function must be filled with either 0 (disable) or 1 (enable). By default, it is disabled. PathVerificationPeriod This setting is used to indicate 30 no change the number of seconds with which MPIO has been requested to perform path verification. This field is only honored if PathVerifyEnabled is TRUE. This timer is specified in seconds. The default is 30 seconds. The maximum allowed is MAXULONG. RetryCount This setting specifies the number 3 no change of times a failed I/O if the DSM (FC or iSCSI determines that a failing request systems) must be retried. This is invoked when DsmInterpretError() returns 15 (front-end Retry = TRUE. The default SAS systems setting is 3. only) RetryInterval This setting specifies the interval 1 no change of time (in seconds) after which a failed request is retried (after the DSM has decided so, and assuming that the I/O has been retried a fewer number of times than RetryCount). This value is specified in seconds. The default is 1 second. DiskPathCheckEnabled If the DiskPathCheckEnabled key - 1 is set to a nonzero value, the MPIO component creates a path recovery worker.

111 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

MPIO Registry Settings: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters Default Recommended Setting name Description value value DiskPathCheckInterval If the DiskPathCheckInterval key - 25 is set to 0, or if the key does not exist, the MPIO component uses a default time interval. The default time interval is half of the time that is set in the PDORemovePeriod parameter.

112 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2.1.3 Recommended Disk registry settings for Windows Server 2008r2

Disk registry settings location: HKLM\SYSTEM\CurrentControlSet\Services\disk

Setting Description Default Recommended name value value

TimeoutValue Disk time-out is a registry setting that 60 no change defines the time that Windows will wait for a hard disk to respond to a command. Installing host bus adapters (HBA) or other storage controllers can cause this key to be created and configured.

A.2.1.4 iSCSI initiator settings for Windows Server 2008r2

These settings apply to single-path and MPIO configurations that use iSCSI to connect to SC Series storage.

Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1- 08002BE10318}\\Parameters Default Recommended Setting name Description value value MaxRequestHoldTime This is the maximum number of 60 90 seconds that requests are queued if connection to the target is lost and the connection is being retried. After this hold period, requests will be failed with error no device and device (disk) will be removed from the system. LinkDownTime This value determines how long 15 35 requests will be held in the device queue and retried if the connection to the target is lost. If MPIO is installed this value is used. If MPIO is not installed MaxRequestHoldTime is used instead. TCPConnectTime Timeout given to TCP when a Connect 15 no change request is sent. TCPDisconnectTime Timeout given to TCP when a 15 no change Disconnect request is sent. WMIRequestTimeout Timeout value set for WMI requests 30 no change such as LoginToTarget or LogoutFromTarget, SendTargets.

113 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1- 08002BE10318}\\Parameters Default Recommended Setting name Description value value DelayBetweenReconnect If a connection is dropped while it is in 5 no change FullFeature phase, the driver will attempt to re-login. This parameter sets the delay between each re-login attempts. MaxConnectionRetries Maximum number of times a lost TCP 4294967295 no change connection will be retried. (indefinitely) MaxPendingRequests This setting controls the maximum 255 no change number of outstanding requests allowed by the initiator. At most this many requests will be sent to the target before receiving response for any of the requests. EnableNOPOut If set to 1, the initiator will send NOP 0 1 OUT PDUs to target if there is no activity for 2 minutes. MaxTransferLength This is maximum data size of an I/O 262144 no change request. (256KB) MaxBurstLength This is the negotiated Max Burst 262144 no change Length. (256KB) FirstBurstLength This is the negotiated First Burst 65536 no change Length. (64KB) MaxRecvDataSegmentLength This is the negotiated 65536 no change MaxRecvDataSegmentLength. (64KB) IPSecConfigTimeout This timeout value is used when the 60 no change driver calls the discovery service to configure\release IPsec for an iSCSI connection. InitialR2T If set to Non-Zero value, initiator will 0 no change request InitialR2T (InitialR2T=Yes). Else initiator will not request InitialR2T (InitialR2T=No). ImmediateData If set to Non-Zero value, initiator will 1 (Yes) no change request ImmediateData (ImmediateData=Yes). Else initiator will not request ImmediateData (ImmediateData=No). PortalRetryCount This value is used to determine how 5 no change many times a connect request to a target portal should be retried if the portal is down.

114 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1- 08002BE10318}\\Parameters Default Recommended Setting name Description value value NetworkReadyRetryCount This value is used to determine how 10 no change many times initiator should retry getting the IP address of NIC corresponding to the PortNumber specified in the login request. ErrorRecoveryLevel Error recovery level that the initiator will 2 no change request.

Enable RFC1323 Timestamps

Enable RFC1323 timestamps (TCP High Performance Extensions) to prevent sequence number wrap under high load, known as Prevention Against Wrapped Sequence (PAWS). High-load iSCSI connections are prone to this issue, particularly at 10GbE or higher. Run this command at elevated CMD prompt to add a registry key (set to value of 2 by default; this is the desired value):

netsh int tcp set global timestamps=enabled

The registry setting can be checked and confirmed as shown below:

• HKLM\SYSTEM\CurrentControlSet\Services\TCPIP\Parameters\Tcp1323Opts • Values: 0 = Timestamps + windows scaling disabled 1 = Windows Scaling Enabled 2 = Timestamps enabled ✓ 3 = both enabled

Disable Nagle’s Algorithm

To disable delayed ACK and Nagle’s algorithm, create the following DWORD 32-bit entries for each SAN interface subkey in the Windows Server registry:

HKLM\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters\Interfaces\ Create or verify these DWORD 32-bit entries. Set them to a value of 1 (disabled) TcpAckFrequency TcpNoDelay

Note: A reboot is required for any registry changes to take effect. Alternatively, unloading and reloading the initiator driver will also cause the change to take effect. In the Device Manager GUI, under Storage controllers, right-click Microsoft iSCSI Initiator, and select Disable to unload the driver. Then, select Enable to reload the driver.

115 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2.2 Windows Server 2012 and Later

A.2.2.1 Recommended updates and hotfixes for Windows Server 2012 and Later

See the Microsoft Update Catalog at https://www.catalog.update.microsoft.com/Home.aspx to locate specific KB downloads.

Windows KB number Title Version

2012 3018489 “No host bus adapter is present” error when querying SAS cable issues in Windows Server 2012 R2 or Windows Server 2012 storport.sys version 6.2.9200.17188 (11/19/14)

3046101 Server may freeze during startup when ALUA- capable storage is used in Windows Server 2012 R2 or Windows Server 2012 mpio.sys version 6.2.9200.17071 (8/5/14) msdsm.sys version 6.2.9200.17362 (5/6/15)

3102997 Data is corrupted after iSCSI sessions or paths recover in Windows Server 2012 R2 or Windows Server 2012 msiscsi.sys version 6.2.9200.21687 (11/8/15)

2012R2 N/A Microsoft publishes updates for Windows Server 2016 2012 R2, Windows Server 2016, and Windows 2019 Server 2019 cumulatively. Any updates for storage- related files are included in the monthly cumulative updates. Apply the latest monthly cumulative update from Microsoft to ensure that the storage-related files msdsm.sys, mpio.sys, msiscsi.sys and storport.sys stay current.

A.2.2.2 Recommended MPIO registry settings for Windows Server 2012 and Later

The recommend registry settings listed in this section can be applied using the registry editor (regedit.exe) or through PowerShell. The registry editor can be used on all versions of Windows Server Desktop (Windows Server with a GUI).

116 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

MPIO Registry Settings: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters Default Recommended Setting name Description value value PDORemovePeriod This setting controls the number 20 120 of seconds that the multipath pseudo-LUN remains in system memory, even after losing all paths to the device. When this timer value is exceeded, pending I/O operations will be failed, and the failure is exposed to the application rather than attempting to continue to recover active paths. The maximum time allowed is MAXULONG (49,000 seconds). PathRecoveryInterval This represents the period after 40 25 which PathRecovery is attempted. This setting is only used if it is not set to 0 and UseCustomPathRecoveryInterval is set to 1. UseCustomPathRecoveryInterval If this key exists and is set to 1, it 0 1 allows the use of PathRecoveryInterval. PathVerifyEnabled This flag enables path 0 1 verification by MPIO on all paths every N seconds (where N depends on the value set in PathVerificationPeriod).

This Boolean function must be filled with either 0 (disable) or 1 (enable). By default, it is disabled. PathVerificationPeriod This setting is used to indicate 30 no change the number of seconds with which MPIO has been requested to perform path verification. This field is only honored if PathVerifyEnabled is TRUE. This timer is specified in seconds. The default is 30 seconds. The maximum allowed is MAXULONG.

117 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

MPIO Registry Settings: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters Default Recommended Setting name Description value value RetryCount This setting specifies the number 3 no change of times a failed I/O if the DSM (FC or iSCSI determines that a failing request systems) must be retried. This is invoked when DsmInterpretError() returns Retry = TRUE. The default setting is 3. 15 (front-end SAS systems only) RetryInterval This setting specifies the interval 1 no change of time (in seconds) after which a failed request is retried (after the DSM has decided so, and assuming that the I/O has been retried a fewer number of times than RetryCount). This value is specified in seconds. The default is 1 second. DiskPathCheckDisabled If the DiskPathCheckDisabled 0 no change key is set to zero, the MPIO component creates a path recovery worker. DiskPathCheckInterval If the DiskPathCheckInterval key 10 25 is set to 0, or if the key does not exist, the MPIO component uses a default time interval. The default time interval is half of the time that is set in the PDORemovePeriod parameter.

118 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2.2.3 Recommended Disk registry settings for Windows Server 2012 and Later

Recommended disk registry settings location: HKLM\SYSTEM\CurrentControlSet\Services\disk

Setting Default Recommended Description name value value

TimeoutValue Disk time-out is a registry setting that defines the 60 no change time that Windows will wait for a hard disk to respond to a command. Installing host bus adapters (HBA) or other storage controllers can cause this key to be created and configured.

A.2.2.4 iSCSI initiator settings for Windows Server 2012 and Later

These settings apply to single-path and MPIO configurations that use iSCSI to connect to SC Series storage.

Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1- 08002BE10318}\\Parameters Default Recommended Setting name Description value value MaxRequestHoldTime This is the maximum number of seconds 60 90 that requests are queued if connection to the target is lost and the connection is being retried. After this hold period, requests will be failed with error no device and device (disk) will be removed from the system. LinkDownTime This value determines how long requests 15 35 will be held in the device queue and retried if the connection to the target is lost. If MPIO is installed this value is used. If MPIO is not installed MaxRequestHoldTime is used instead. TCPConnectTime Timeout given to TCP when a Connect 15 no change request is sent. TCPDisconnectTime Timeout given to TCP when a Disconnect 15 no change request is sent. WMIRequestTimeout Timeout value set for WMI requests such 30 no change as LoginToTarget or LogoutFromTarget, SendTargets. DelayBetweenReconnect If a connection is dropped while it is in 5 no change FullFeature phase, the driver will attempt to re-login. This parameter sets the delay between each re-login attempts.

119 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

Recommended iSCSI initiator registry settings location: HKLM\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1- 08002BE10318}\\Parameters Default Recommended Setting name Description value value MaxConnectionRetries Maximum number of times a lost TCP 4294967295 no change connection will be retried. (indefinitely) MaxPendingRequests This setting controls the maximum number 255 no change of outstanding requests allowed by the initiator. At most this many requests will be sent to the target before receiving response for any of the requests. EnableNOPOut If set to 1, the initiator will send NOP OUT 0 1 PDUs to target if there is no activity for 2 minutes. MaxTransferLength This is maximum data size of an I/O 262144 no change request. (256KB) MaxBurstLength This is the negotiated Max Burst Length. 262144 no change (256KB) FirstBurstLength This is the negotiated First Burst Length. 65536 no change (64KB) MaxRecvDataSegmentLength This is the negotiated 65536 no change MaxRecvDataSegmentLength. (64KB) IPSecConfigTimeout This timeout value is used when the driver 60 no change calls the discovery service to configure\release IPsec for an iSCSI connection. InitialR2T If set to Non-Zero value, initiator will 0 no change request InitialR2T (InitialR2T=Yes). Else initiator will not request InitialR2T (InitialR2T=No). ImmediateData If set to Non-Zero value, initiator will 1 (Yes) no change request ImmediateData (ImmediateData=Yes). Else initiator will not request ImmediateData (ImmediateData=No). PortalRetryCount This value is used to determine how many 5 no change times a connect request to a target portal should be retried if the portal is down. NetworkReadyRetryCount This value is used to determine how many 10 no change times initiator should retry getting the IP address of NIC corresponding to the PortNumber specified in the login request. ErrorRecoveryLevel Error recovery level that the initiator will 2 no change request.

120 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

Enable RFC1323 Timestamps

Enable RFC1323 timestamps (TCP High Performance Extensions) to prevent sequence number wrap under high load, known as Prevention Against Wrapped Sequence (PAWS). High-load iSCSI connections are prone to this issue, particularly at 10GbE or higher. Run this command at elevated CMD prompt to add a registry key (set to value of 2 by default; this is the desired value):

netsh int tcp set global timestamps=enabled

The registry setting can be checked and confirmed as shown below:

• HKLM\SYSTEM\CurrentControlSet\Services\TCPIP\Parameters\Tcp1323Opts • Values: 0 = Timestamps + windows scaling disabled 1 = Windows Scaling Enabled 2 = Timestamps enabled ✓ 3 = both enabled

Disable Nagle’s Algorithm

To disable delayed ACK and Nagle’s algorithm, create the following DWORD 32-bit entries for each SAN interface subkey in the Windows Server registry:

HKLM\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters\Interfaces\ Create or verify these DWORD 32-bit entries. Set them to a value of 1 (disabled) TcpAckFrequency TcpNoDelay

Disable NIC Interrupt Modulation:

1. Click Adapter Settings. 1. Right-click the adapter and select Properties. 2. Under the Networking tab, click Configure. 3. Under the Advanced tab, select Interrupt Moderation and choose Disabled.

Note: A reboot is required for any registry changes to take effect. Alternatively, unloading and reloading the initiator driver will also cause the change to take effect. In the Device Manager GUI, under Storage controllers, right-click Microsoft iSCSI Initiator, and select Disable to unload the driver. Then, select Enable to reload the driver.

121 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2.3 Linux (Red Hat, SuSE, Oracle, Ubuntu)

A.2.3.1 FC PortDown timeout

The HBA PortDown timeout parameter dictates how long a Linux system waits before destroying a connection after being losing its connectivity with the port. The PortDown timeout is generally set to 60 seconds for the SC Series storage system.

To configure the PortDown timeout in the HBA driver module, add or append the following options to the appropriate HBA driver module configuration file and reload the driver module.

A. For Qlogic, add in /etc/modprobe.d/qla2xxx.conf

options qla2xxx qlport_down_retry=60

Reload the module

# modprobe –r qla2xxx # modprobe qla2xxx

B. For Emulex, add in /etc/modprobe.d/lpfc.conf

options lpfc lpfc_devloss_tmo=60

Reload the module

# modprobe –r lpfc # modprobe lpfc

A.2.3.2 Verifying parameters

To verify that the configuration changes have taken effect, examine the driver module parameter values in their respective files.

A. For QLogic:

# cat /sys/module/qla2xxx/parameters/qlport_down_retry

B. For Emulex:

# cat /sys/module/lpfc/parameters/lpfc_devloss_tmo

# cat /sys/class/scsi_host/hostX/lpfc_devloss_tmo #where X is the HBA no.

A.2.3.3 FC/iSCSI volume multipath configuration

A basic template can be copied from /usr/share/doc/device-mapper-multipath- /multipath.conf to /etc/multipath.conf as a starting point. Any settings that are not defined explicitly in the file would assume the default values. The full list of these settings can be obtained using the following command. Specific SC Series storage system settings can be found by searching for COMPELNT from the output.

122 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

# multipathd –k"show config"

To avoid confusion and as a best practice, it is recommended to always explicitly define the SC Series storage in /etc/multipath.conf. The following example show multipath configuration for SC Series volumes on RHEL 6 and newer. Please note that these configurations apply only in FC and iSCSI implementations. The SAS multipath configuration is discussed in section A.2.3.5 and should be used instead in SAS implementations.

defaults { user_friendly_names yes find_multipaths yes }

devices { device { vendor "COMPELNT" product "Compellent Vol" path_grouping_policy multibus path_selector "service-time 0" # See note below path_checker tur features "0" hardware_handler "0" prio const failback immediate rr_weight uniform no_path_retry queue } }

Note: "round-robin 0" is the default for RHEL 6 and older. "service-time 0" is the default for RHEL 7 and newer. Both are acceptable values for SC Series FC/iSCSI volumes.

Once the configuration file is in place, reload multipathd with the updated configuration.

# multipath -r # multipath –ll

A.2.3.4 iSCSI timeout for multipath environments

The pre-configured iSCSI settings, defined in /etc//iscsi.conf, work with SC Series storage system when the Linux system is also configured to use dm-multipath. It is a best practice to use dm- multipath for path redundancy and failover. It is important to note the following timeout settings because they directly affect the storage availability and failure recovery for a SAN storage system. When a SC Series storage system controller fails, services and volumes fail over to the surviving controller and this failover might take up to 60 seconds. Therefore ensure the iSCSI timeout settings are sufficient to accommodate this kind of events. These pre-configured timeout settings, listed below, work well with SC Series storage systems.

• node.conn[0].timeo.noop_out_interval = 5 • node.conn[0].timeo.noop_out_timeout = 5

123 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

• node.session.timeo.replacement_timeout = 120

A.2.3.5 SAS volume multipath configuration

SAS connectivity to a Linux system requires specific configuration schema in the /etc/multipath.conf file. Add the following device section to /etc/multipath.conf used exclusively for SAS-connected Linux systems. The following example define the configuration parameters for all devices identified by vendor="COMPELNT" and product="Compellent Vol".

devices { device { vendor COMPELNT product "Compellent Vol" path_checker tur prio alua path_selector "service-time 0" path_grouping_policy group_by_prio no_path_retry 24 hardware_handler "1 alua" failback immediate rr_weight priorities } }

A properly configured SAS volume will return the following multipath -ll output. This SC Series volume is discovered as a multipath ALUA-capable volume, where each path is capable of I/O. The path represented by prio=50 (active/optimized path) is used for all active I/O requests. The path represented by prio=1 (standby path) is a highly available, redundant path and is used when the active/optimized path becomes unavailable.

# multipath -ll Compelnt_0016 (36000d31000feb3000000000000000016) dm-3 COMPELNT,Compellent Vol size=100G features='1 queue_if_no_path' hwhandler='1 alua' wp=rw |-+- policy='service-time 0' prio=50 status=active | `- 1:0:0:1 sdb 8:16 active ready running `-+- policy='service-time 0' prio=1 status=enabled `- 1:0:1:1 sdc 8:32 active ready running Compelnt_001a (36000d31000feb300000000000000001a) dm-4 COMPELNT,Compellent Vol size=100G features='1 queue_if_no_path' hwhandler='1 alua' wp=rw |-+- policy='service-time 0' prio=50 status=active | `- 1:0:1:2 sdd 8:48 active ready running `-+- policy='service-time 0' prio=1 status=enabled `- 1:0:2:2 sde 8:64 active ready running

124 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2.4 VMware

A.2.4.1 SAS HBA settings

For SC Series arrays that have SAS front-end ports, use the following recommendations.

For the mpt3sas, use all the default driver module settings.

For the lsi_msgpt3, change the following module parameter setting as recommended by the Dell KB article Driver Compatibility with Front End SAS Connectivity.

esxcli system module parameters set -p issue_scsi_cmd_to_bringup_drive=0 -m lsi_msgpt3

A.2.4.2 Setting round robin to be the default path selection policy

The round robin path selection policy (PSP) should be set to the default using the following command. After creating the claim rule and rebooting, all SC Series volumes and protocol endpoints will acquire this policy.

esxcli storage nmp satp rule add -s VMW_SATP_ALUA -V COMPELNT -P VMW_PSP_RR -o disable_action_OnRetryErrors -e "Dell EMC SC Series Claim Rule"

A.2.4.3 Fibre Channel adapter driver settings by vendor

Fibre Channel: QLogic driver module settings for queue depth and controller failover

esxcli system module parameters set -m qlnativefc -p "ql2xmaxqdepth=255 ql2xloginretrycount=60 qlport_down_retry=60"

Fibre Channel: Emulex driver module settings for queue depth and controller failover

esxcli system module parameters set -m lpfc820 -p "lpfc_devloss_tmo=60 lpfc_lun_queue_depth=254"

A.2.4.4 Setting ARPRedirect on specified hardware iSCSI adapter

esxcli iscsi physicalnetworkportal param set --option ArpRedirect –v=1 -A vmhbaXX

A.2.4.5 Set software based iSCSI login timeout

esxcli iscsi adapter param set –A=vmhbaXX –k=LoginTimeout –v=5

A.2.4.6 Set software based iSCSI Queue Depth

esxcli system module parameters set -m iscsi_vmk -p iscsivmk_LunQDepth=255

A.2.4.7 Setting ALUA mode for FCoE based volumes

esxcli storage nmp satp rule add -R fcoe -s VMW_SATP_ALUA

125 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2.5 Oracle Solaris

A.2.5.1 QLogic settings set in /kernel/drv/qlc.conf

login-retry-count=60;

port-down-retry-count=60;

link-down-timeout=30;

connection_options=1;

A.2.5.2 Emulex settings in /kernel/drv/emlxs.conf

topology=2;

A.2.5.3 Solaris 10 & 11 Timeouts (reboot required)

In /kernel/drv/fcp.conf

fcp_offline_delay=60;

In /kernel/drv/fp.conf

fp_offline_ticker=90;

126 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2.6 IBM AIX

A.2.6.1 Dell EMC MPIO ODM Path Control Module

The Dell EMC MPIO ODM Path Control Module must be installed on the AIX server for proper operation with the Storage Center.

A.2.6.2 Dynamic Tracking

Dynamic tracking must be enabled on fibre channel adapters. Dynamic tracking is enabled by default on all systems Running AIX 7.1 and higher. Dynamic tracking is also enabled on all VFC adapters in LPARs and cannot be disabled.

1. Determine fibre channel adapter names a. lsdev | grep fscsi 2. Determine if Dynamic Tracking is enabled a. lsattr -El fscsi[n] | grep dyntr 3. Enabled Dynamic Tracking for all fibre channel adapters where it’s not a. chdev -l fscsi[n] -a dyntrk=yes –P 4. Set fast_fail when Dynamic Tracking is enabled (-P applies after reboot) a. chdev -l fscsi0 -a fc_err_recov=fast_fail –P

127 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2.7 Citrix Hypervisor (XenServer)

A.2.7.1 XenServer Versions 5.x to 6.2

For Citrix XenServer versions 5.x through 6.2, to ensure that XenServer volumes will persist after a Storage Center controller failover, apply the following timeout values. These settings are located in the mpathHBA •le located in the /opt/xensource/sm/ directory. When fnished, save the file and reboot the server.

Citrix XenServer HBA Settings for Versions 5.x to 6.2

Field Setting

DEFAULT_TIMEOUT 60

MPATH_TIMEOUT 60

A.2.7.2 XenServer Version 6.5 and Later

For Citrix XenServer version 6.5 and later, the multipath configuration file has been relocated. To ensure that XenServer volumes will persist after a Storage Center controller failover, apply the following timeout value. This setting is located in the defaults section of the multipath.conf configuration file located in the /etc directory. When •nished, save the •le and reboot the server.

The following code provides an example:

defaults { user_friendly_names no replace_wwid_whitespace yes dev_loss_tmo 30 }

Note: The default value for the dev_loss_tmo timeout setting is 30. However, Dell EMC recommends that the default is set to 60.

Citrix XenServer HBA Settings for Version 6.5 and Later

Field Setting

dev_loss_tmo 60

128 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Required Adapter and Server OS Settings

A.2.8 HP-UX 11i

Configure the HP-UX environment to match the following configurations based on the version of HP-UX running on the server.

A.2.8.1 V 2 and Earlier

HP-UX version 11.21 and earlier does not require changes. However, a Cisco fabric with Persistent FCID enabled is required to survive a Dell Storage Center failover or port rebalance.

A.2.8.2 V 3

HP-UX version 11.31 works best with Storage Center when Agile Addressing is enabled. With HP-UX version 11.31, Storage Center requires that Agile Addressing be enabled for proper failover of Storage Center storage systems.

129 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM SC and SCv Fibre Channel Zoning

B SC and SCv Fibre Channel Zoning

Front-end zoning on a Fibre Channel fabric can be configured using either (WWN) zoning or Brocade Peer Zoning.

Storage Center zones when using WWN zoning: • Include all Storage Center virtual WWPNs in a single zone. • Include all Storage Center physical WWPNs in a single zone.

Server zones when using WWN zoning: • For each server HBA port, create a zone that includes the HBA port WWPN and multiple Storage Center virtual WWPNs in the same FC fabric.

Storage Center zone when using Peer Zoning: • Include all Storage Center physical WWPNs in a single standard WWN zone.

Server zone when using Peer Zoning: • Include all Storage Center virtual WWPNs as the Principal Members of the Peer Zone. • Include all server HBA port WWPNs as the Peer Members of the Peer Zone.

NOTE: Brocade FOS 8.1 or greater is required to include aliases in Peer Zones.

SC to SC replication zoning on a Fibre Channel fabric can be configured with WWN zoning.

Storage Center replication zones when using WWN zoning: • Include all designated physical WWPNs from system A and system B in a single zone. • Include all designated physical WWPNs of system A and the virtual WWPNs of system B in a single zone. • Include all designated physical WWPNs of system B and the virtual WWPNs of system A in a single.

Note: Not all SC ports must be used or dedicated for SC replication, however ports that are used must be in these zones and in the same FC fabric.

Note: Do not use Brocade Peer Zoning for Fibre Channel Replication zones.

130 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

C Deprecated devices

C.1 Host configurations

The host configurations listed below have been previously tested for use with Dell Storage products, but they are no longer tested by Dell. These configurations are supported at Level 2 if the vendor is actively providing support, or at Level 3 if vendor support is no longer available.

C.1.1 SC Series

C.1.1.1 HBA and CNA HW initiators

Vendor Operating System OS HBA Model Last Driver Last Last FW Last Bf Protoco Version Vendor Boot Adapter Arra S l Code y OS Apple OS X 6.8 LSI 7x02EP 2.5.0 N/A 1.2.18.0 6.1.x L3 FC Apple OS X 7x04EP N/A N/A 1.3.23.0 6.2.x L3 FC Apple OS X 8.2 LSI 7x04EP Built-in N/A 1.3.23.0 6.5.x L3 FC Apple OS X 9.5 LSI 7x04EP Built-in N/A 1.3.23.0 6.6.x L3 FC Citrix XenServer 5.6 QLogic QxE25xx N/A N/A N/A 6.3.x L3 FC Citrix XenServer QLx406x Built-in N/A N/A 5.5.x L3 iSCSI Citrix XenServer 6.0 Emulex LPx1200x 8.3.5.77.1p 2.12a6 2.00a4 6.2.x L1 FC Citrix XenServer 6.1 Emulex LPx1200x 8.3.5.77.1p 2.12a10 2.01a10 6.4.x L1 FC Citrix XenServer 6.2 Emulex LPx1200x 8.3.7.14 5.13a3 2.01a12 6.6.x L1 FC Citrix XenServer QLogic QxE25xx 8.5.0.3.55.6-k 3.27 7.04.0 6.6.x L1 FC HP HP-UX 11i v2 Emulex LP900x 4.32.03 N/A 3.93a0 5.2.x L3 FC

131 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Operating System OS HBA Model Last Driver Last Last FW Last Bf Protoco Version Vendor Boot Adapter Arra S l Code y OS HP HP-UX 11i v2 HP A6795A B.11.23.0709 1.37 N/A 6.4.x L3 FC HP Tru-64 5.1A HP FCA2684 2.14 N/A 1.90a4 6.3.x L3 FC HP OpenVMS 8.3 HP FCA2354 N/A N/A N/A 6.2.x L1 FC IBM AIX 5.2 Cambex PC200x 2.5.10.39 N/A 3.3.19 5.5.x L3 FC IBM AIX 5.3 Cambex PC400x 3.0.0.9 N/A 4.00.29 4.x.y L3 FC IBM AIX IBM 575x 5.3.90 1.50a4 10x8 6.0.x L1 FC IBM AIX 577D 6.1.6.0 3.10a3 2.00x7 6.2.x L1 FC IBM AIX 6.1 QLogic QLx405x Built-in N/A N/A 5.3.x L3 iSCSI Microsoft Windows Server 2003 QLogic QLx405x 2.1.4.26 N/A 3.0.1.53 6.0.x L3 iSCSI Microsoft Windows Server QLx406x 2.1.4.26 2.09 3.0.1.75 6.6.x L1 iSCSI Microsoft Windows Server 2003 R2 Emulex LPx1100x 7-2.10a7 5.03a0 2.80a4 5.0.x L3 FC Microsoft Windows Server 2003 R2 LPx1200x 5.2.70.018 5.13a3 2.01a12 6.7.x L1 FC Microsoft Windows Server 2003 R2 7.2.50.007 2.12a6 2.00a4 6.0.x L1 FC Microsoft Windows Server 2003 R2 QLogic QLA23xx 9.1.7.16 1.43 3.3.25 4.x.y L1 FC Microsoft Windows Server 2003 R2 QxE24xx 9.1.9.27 3.00 5.4.4 6.0.x L1 FC Microsoft Windows Server 2003 R2 QxE25xx 9.1.9.27 3.13 5.4.4 6.4.x L3 FC Microsoft Windows Server 2003 R2 QxE81xx 9.1.7.18 N/A 5.1.3 4.x L1 FCoE Microsoft Windows Server 2008 Emulex LPx1100x 7.230.016 5.03a0 2.82a4 5.4.x L3 FC Microsoft Windows Server 2008 LPx1200x 7.2.70.014 2.12a6 2.00a4 6.2.x L1 FC Microsoft Windows Server 2008 QLogic QLA23xx 9.1.7.18 1.54 3.3.25 5.2.x L1 FC

132 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Operating System OS HBA Model Last Driver Last Last FW Last Bf Protoco Version Vendor Boot Adapter Arra S l Code y OS Microsoft Windows Server 2008 QxE24xx 9.1.9.27 3.00 5.4.4 6.0.x L1 FC Microsoft Windows Server 2008 QxE25xx 9.1.10.26 3.13 5.6.5 6.4.x L1 FC Microsoft Windows Server 2008 QLx405x 2.1.4.19 N/A 3.0.1.53 5.2.x L3 iSCSI Microsoft Windows Server 2008 QLx406x 2.1.5.25 3.0.1.53 3.0.1.53 5.5.x L2 iSCSI Microsoft Windows Server 2012 Emulex LPx1600x 10.2.370.8 KT8.03a1 10.0.803.2 6.6.x L1 FC 5 5 Microsoft Windows Server OCE1010x- 10.2.421.0 2.0.1.35 4.16.17 6.6.x L1 iSCSI i Microsoft Windows Server QLogic QxE25xx 9.1.12.21 3.27 7.4.0 6.6.x L1 FC Microsoft Windows Server QxE266x 9.1.12.21 3.27 7.4.1 6.6.x L1 FC QLE267x QLE267x Microsoft Windows Server BRCM578x 7.8.12.0 7.85 7.8.57.0 6.4.x L1 FCoE x Microsoft Windows Server QxE82xx 9.1.11.12 3.23 4.16.17 6.4.x L1 FCoE Microsoft Windows Server 2.1.6.10 2.0.1.35 4.16.17 6.6.x L1 iSCSI Microsoft Windows Server QLx406x 2.1.4.27 2.09 3.0.1.75 6.6.x L1 iSCSI Novell Netware 6.5-SP6 QLogic QLx24xx 6.90o 1.24 4.00.26 4.x.y L3 FC Novell Netware 6.5-SP7 QLogic QLA23xx 6.90o 1.24 3.03.20 5.3.x L1 FC Novell Netware 6.5-SP8 QLogic QLA23xx 6.90o 1.5 3.03.21 6.4.x L1 FC SUSE SUSE Linux Enterprise 10 Emulex LPx1200x 8.2.0.92.1p 5.13a0 2.01a12 6.5.x L1 FC Server SUSE QLogic QLx405x 5.01.03.03.10.03-d4 N/A 3.0.1.53 6.0.x L3 iSCSI

133 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Operating System OS HBA Model Last Driver Last Last FW Last Bf Protoco Version Vendor Boot Adapter Arra S l Code y OS SUSE QLx406x 5.03.01.11.10.4-d0 N/A 3.0.1.75 6.5.x L3 iSCSI Oracle Linux Server (UEK) 6.3 QLogic QLx24xx 8.2.0.10.10.3-k4 1.29 4.4.9 6.3.x L1 FC Oracle Linux Server (UEK) 6.4 QLogic QxE25xx 8.04.00.11.39.o-k 3.20 5.8.0 6.4.x L1 FC Oracle Linux Server (UEK) QxE266x 8.04.00.11.39.o-k 3.20 6.4.0 6.4.x L3 FC QLE267x Oracle Oracle Virtual Machine 3.2.x QLogic QxE25xx 8.05.00.03.39.0-k1 3.20 5.9.0 6.5.x L3 FC Oracle QxE266x 8.05.00.03.39.0-k1 3.19 6.6.3 6.5.x L3 FC QLE267x/Q LE267x Oracle Solaris (SPARC) 9 QLogic QLA23xx 2.19 1.43 3.3.119 6.1.x L3 FC Oracle QLogic QLx401x 5.00 N/A 3.0.0.04 4.x.y L3 iSCSI RedHat Enterprise Linux 5.0 QLogic QLA23xx 8.01.07-k7 1.43 3.3.20 4.x.y L1 FC RedHat Enterprise Linux 5.1 QLogic QLA23xx 8.01.07-k7 1.43 3.3.20 4.x.y L1 FC

RedHat Enterprise Linux QLx406x 5.01.01.04 N/A 3.0.1.24 4.x.y L3 iSCSI RedHat Enterprise Linux 5.2 Emulex LPx1200x 8.2.0.29 5.03a2 1.10a5 4.x.y L3 FC RedHat Enterprise Linux QLogic QLA23xx 8.02.00-k5 1.43 3.3.26 5.0.x L3 FC RedHat Enterprise Linux QLx406x 5.01.00-k8 N/A 3.0.1.24 5.0.x L3 iSCSI RedHat Enterprise Linux 5.3 QLogic QxE24xx 8.02.00.06.05.03-k 1.29 4.4.5 4.x.y L1 FC RedHat Enterprise Linux QLx406x 5.01.03.04 N/A 3.0.1.53 4.x.y L3 iSCSI RedHat Enterprise Linux 5.4 QLogic QLA23xx 8.03.00.10.05.04-k 1.43 3.3.26 5.2.x L1 FC RedHat Enterprise Linux QxE24xx 8.03.00.10.05.04-k 1.29 4.4.9 5.4.x L1 FC

134 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Operating System OS HBA Model Last Driver Last Last FW Last Bf Protoco Version Vendor Boot Adapter Arra S l Code y OS RedHat Enterprise Linux QLx406x 8.03.00.10.05.04-k N/A 3.0.3.26 5.2.x L3 iSCSI RedHat Enterprise Linux 5.5 QLogic QxE24xx 8.03.01.04.05.05-k 1.29 4.4.9 6.0.x L1 FC RedHat Enterprise Linux QLx406x 5.01.00.01.05.04-k9 N/A 3.0.1.53 6.0.x L3 iSCSI RedHat Enterprise Linux 5.7 QLogic QxE24xx 8.03.07.03.05.07-k 3.00 5.3.16 5.5.x L1 FC RedHat Enterprise Linux QLx406x 5.02.15.01.05.07-k0 N/A 3.0.1.53 5.5.x L3 iSCSI RedHat Enterprise Linux 5.8 QLogic QxE25xx 8.3.7.9.5.8-k 3.13 5.7.0 6.3.x L1 FC RedHat Enterprise Linux QLx406x 5.02.15.01.05.07-k0 N/A 3.0.1.53 6.3.x L3 iSCSI RedHat Enterprise Linux 5.9 QLogic QxE25xx 8.3.7.15.5.9-k 3.20 5.9.0 6.4.x L1 FC RedHat Enterprise Linux QLx406x 5.02.04.05.05.09-d0 N/A 3.0.1.75 6.4.x L3 iSCSI RedHat Enterprise Linux 5.10 Emulex LPx1200x 8.2.0.128.3p 5.13a0 2.01a12 6.5.x L1 FC RedHat Enterprise Linux QLogic QxE25xx 8.03.07.15.05.09-k 3.24 7.1.0 6.5.x L1 FC RedHat Enterprise Linux QLx406x 5.02.04.06.05.10-d0 N/A 3.0.1.75 6.5.x L3 iSCSI RedHat Enterprise Linux 5.11 Emulex LPx1200x 8.2.0.128.3p 5.13a3 2.01A12 6.6.x L1 FC RedHat Enterprise Linux QLogic QLx25xx 8.03.07.15.05.09-k 3.27 7.4.0 6.6.x L1 FC RedHat Enterprise Linux QLx406x 5.02.04.06.05.10-d0 N/A 3.0.1.75 6.6.x L3 iSCSI RedHat Enterprise Linux 6.0 Emulex LPx1200x 8.3.5.17 5.03a2 1.10a5 6.0.x L1 FC RedHat Enterprise Linux 6.2 Emulex LPx1200x 8.3.5.68.5p 5.12a9 2.01a10 6.3.x L1 FC RedHat Enterprise Linux QLogic QLx406x 5.2.15.5.5.6-c0 N/A 3.0.1.53 6.2.x L3 iSCSI RedHat Enterprise Linux 6.3 Cisco VIC-1280 1.5.0.1 2.2(1c) 2.2(1c) 6.5.x L1 FCoE RedHat Enterprise Linux Emulex LPx1200x 8.3.5.68.5p 5.12a9 2.01a10 6.3.x L1 FC

135 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Operating System OS HBA Model Last Driver Last Last FW Last Bf Protoco Version Vendor Boot Adapter Arra S l Code y OS RedHat Enterprise Linux QLx406x 5.2.0.0.6.3-k4 N/A 3.0.1.53 6.3.x L3 iSCSI RedHat Enterprise Linux 6.4 Emulex LPx1200x 8.3.5.68.5p 2.12a11 2.01a11 6.4.x L1 FC RedHat Enterprise Linux QLogic QxE25xx 8.04.00.08.06.4-k 3.20 5.9.0 6.4.x L1 FC RedHat Enterprise Linux QLx406x 5.02.0.00.06.03-k4 N/A 3.0.1.75 6.4.x L3 iSCSI VMware ESX/ESXi 4.0 Emulex LP2100x 8.2.0.30.53 N/A 1.00 5.5.x L1 FC VMware ESX/ESXi LPx1200x 8.2.0.30.53 2.12a6 2.00a4 6.0.x L1 FC VMware ESX/ESXi QLogic QxE24xx 8.02.01-k1-vmw43 1.29 4.04.09 5.4.x L1 FC VMware ESX/ESXi QxE25xx 8.02.01-k1-vmw48 3.00 4.04.09 6.0.x L1 FC VMware ESX/ESXi QxE81xx 841.k1.28.1-1vmw 2.13 5.01.03 6.0.x L1 FCoE VMware ESX/ESXi QLx406x 5.01.03.1-9vmw N/A 3.00.01.24 5.4.x L3 iSCSI VMware ESX/ESXi 4.1 Emulex LPx1200x 8.2.1.141.55 2.12a11 2.01a11 6.5.x L1 FC VMware ESX/ESXi LPe12xx 8.2.1.141.55 6.03x1 2.01a10 6.4.x L1 FC VMware ESX/ESXi LPx1600x 8.2.1.141.55 1.1.21.4 1.1.21.4 6.4.x L1 FC VMware ESX/ESXi OCx1010x 8.2.1.141.55 N/A 4.2.324.30 6.3.x L1 FCoE VMware ESX/ESXi OCx1110x 8.2.1.151.65 4.6.142.1 4.6.142.10 6.5.x L1 FCoE 0 VMware ESX/ESXi QLogic QxE24xx 841.k1.50.1-1vmw 3.20 5.09.00 6.4.x L1 FC VMware ESX/ESXi QxE25xx 841.k1.61.1-1vmw 3.20 5.09.00 6.5.x L1 FC VMware ESX/ESXi QxE266x 841.k1.50.1-1vmw 3.24 7.00.01 6.4.x L1 FC QLE267x

136 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Operating System OS HBA Model Last Driver Last Last FW Last Bf Protoco Version Vendor Boot Adapter Arra S l Code y OS VMware ESX/ESXi BR-M1741- 3.2.0.0 3.2.1.0 3.2.0.0 6.4.x L3 FCoE k VMware ESX/ESXi QxE81xx 841.k1.61.1-1vmw 3.23 7.00.02 6.5.x L1 FCoE VMware ESX/ESXi QxE82xx 841.k1.50.1-1vmw 3.23 4.16.17 6.4.x L1 FCoE VMware ESX/ESXi QLx406x 534.4.7.0-1vmw 2.09 3.00.01.75 6.5.x L3 iSCSI VMware ESX/ESXi QxE82xx 534.4.7.0-1vmw 2.19 4.16.17 6.5.x L1 iSCSI VMware ESX/ESXi 5.0 Emulex LPx12xx 8.2.4.141.55 6.03x1 2.01a10 6.3.x L1 FC VMware ESX/ESXi LPx1200x 8.2.4.141.55 2.12a10 2.01a10 6.3.x L1 FC VMware ESX/ESXi LPx1600x 8.2.4.141.55 1.1.21.4 1.1.21.4 6.3.x L1 FC VMware ESX/ESXi OCe1010x 8.2.4.141.55 4.2.324.3 5.2.324.30 6.3.x L1 FCoE 0 VMware ESX/ESXi OCe1110x 8.2.1.141.55 4.4.249.3 4.4.249.3 6.3.x L1 iSCSI VMware ESX/ESXi QLogic QxE25xx 934.5.6.0-1vmw 3.13 5.06.05 6.3.x L1 FC VMware ESX/ESXi QxE266x 934.5.6.0-1vmw 3.17 6.04.00 6.3.x L1 FC QLE267x QLE267x VMware ESX/ESXi BR-M1741- 3.2.0.0 3.2.0.0 3.2.0.0 6.3.x L1 FCoE k VMware ESX/ESXi QxE81xx 934.5.6.0-1vmw 3.13 5.7.0 6.3.x L1 FCoE VMware ESX/ESXi QxE82xx 934.5.6.0-1vmw 3.14 4.12.10 6.3.x L1 FCoE VMware ESX/ESXi 634.5.7.0-1vmw 2.12 4.10.8 6.3.x L1 iSCSI VMware ESX/ESXi QLx406x 634.5.7.0-1vmw N/A 3.00.01.53 6.3.X L3 iSCSI

137 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Operating System OS HBA Model Last Driver Last Last FW Last Bf Protoco Version Vendor Boot Adapter Arra S l Code y OS VMware ESX/ESXi 5.1 Emulex LPx12xx 10.2.459.0 6.03X1 2.01A12 6.6.x L1 FC VMware ESX/ESXi LPx1500x 10.0.727.24 1.1.21.4 10.2.506.1 6.6.x L1 FC 9 VMware ESX/ESXi LPx1600x 10.0.727.24 1.1.21.4 10.2.506.1 6.6.x L1 FC 9 VMware ESX/ESXi OCx1110x 8.2.4.146.62 4.6.142.1 4.6.142.10 6.5.x L1 FCoE 0 VMware ESX/ESXi QLogic QxE25xx 934.5.45.0 3.24 7.03.00 6.6.x L1 FC VMware ESX/ESXi QxE266x 934.5.20.0-1vmw 3.24 7.00.01 6.5.x L1 FC QLE267x VMware ESX/ESXi BR-M1741- 3.2.1.0 3.2.1.0 3.2.1.0 6.4.x L1 FCoE k VMware ESX/ESXi BRCM578x 1.711.10.v50.3 N/A 7.10.18 6.6.x L3 FCoE x VMware ESX/ESXi QxE81xx 934.5.20.0-1vmw 3.23 7.0.2 6.5.x L1 FCoE VMware ESX/ESXi QxE82xx 934.5.45.0 3.23 4.16.101 6.6.x L1 FCoE VMware ESX/ESXi 5.1 644.5.35 2.19 4.16.101 6.6.x L1 iSCSI

138 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

C.1.1.2 SW initiators

Vendor iSCSI Initiator/ Last Initiator Version SCOS iSCSI Boot Operating System Citrix XenServer 5.x 6.2.x (2.0-871) 6.5.x, 6.6.x L3 Hewlett-Packard HP-UX 11i B.11.31.03 5.4.2, 5.5.2, 5.5.3, 5.5.4, 6.0.1, 6.0.2, 5.5.10, L3 6.2.1, 6.3.1 IBM AIX 5.3 5.3.0.50 4.1.x, 4.2.x, 4.5.x, 5.0.x, 5.1.x, 5.2.x, 5.3.x, L3 5.4.x, 5.5.x, 6.2.x 4.2.x, 4.5.x, 5.0.x, 5.1.x 5.2.x, 5.3.x, 5.4.x, Microsoft Windows 2003 R2 5.2.3790.3825 5.5.x, L3 6.0.x, 6.1.x, 6.2.x, 6.3.x, 6.4.x, 6.5.x, 6.6.x Windows 2008 6.1.6002.18005 5.5.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, 6.4.x L3 Novell Netware 6.5 1.06.03 4.1.x, 4.2.x L3 SUSE SUSE Linux Enterprise Server 10 2.0-868 5.5.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, 6.4.x, 6.5.x L3 Oracle Solaris 10 (SPARC) 20121113-0 7.0.x, 7.1.x L3 Solaris 10(x86) 20120627-0 6.3.x, 6.4.x, 6.5.x, 6.6.x, 6.7.x, 7.0.x, 7.1.x L3 Linux Server UEK 6.3 6.2.0-872.41 5.5.x, 6.3.x L3 Linux Server UEK 6.4 6.2.0-873.-2.0.2 6.4.x L3 RedHat RHEL 5 6.2.0.872-16 6.4.x, 6.5.x, 6.6.x, 6.7.x L3 VMware ESX 3.5 3.5U5 4.1.x, 4.2.x, 4.5.x, 5.0.x, 5.1.x, 5.2.x, 5.3.x, L3 5.4.x, 5.5.x, 6.0.x vSphere 4.0 In-Box 4.5.x, 5.0.x, 5.1.x, 5.2.x, 5.3.x, 5.4.x, 5.5.x, L3 6.0.x

139 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor iSCSI Initiator/ Last Initiator Version SCOS iSCSI Boot Operating System vSphere 4.1/ESXi 4.1 In-Box 5.3.x, 5.4.x, 5.5.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, L3 6.4.x, 6.5.x vSphere 5.0 In-Box 5.5.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x L3 vSphere 5.1 In-Box 5.5.x, 6.3.x, 6.4.x, 6.5.x L3

140 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

C.1.2 PS Series

C.1.2.1 CNA HW initiators

Vendor Operating OS CNA Model Last Vendor Driver Last Boot Last PS OS Array Bf DCB System Version Vendor Code OS S Microsoft Windows Server 2003 Broadcom BRCM570x 5.2.11.0 N/A N/A 4.0.x L1 N/A QLogic BCM577xx 5.2.11.0 N/A N/A 4.0.x L1 N/A QLx405x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A QLx406x 2.1.4.26 N/A 3.0.1.53 3.2.8 L1 N/A 2008 Broadcom BRCM570x 5.2.11.0 N/A N/A 4.0.x L1 N/A QLogic BCM577xx 5.2.11.0 N/A N/A 4.0.x L1 N/A QLx405x 2.1.4.19 N/A 3.0.1.53 3.2.8 L1 N/A 2012 Broadcom BCM570x 7.12.0.0 7.12.1 7.12.19 9.0.x L1 N/A BCM577xx 7.12.0.0 7.12.1 7.12.19 9.0.x L1 N/A Emulex OCE1010x-i 4.2.281.0 2.0.42.0 4.2.324.11 7.1.x L1 L3 OCx1410x 10.6.116.0 10.6.133.10 10.6.144.21 9.0.x L1 L1 QLogic QLx406x 2.1.5.37 N/A 7.1.x L1 N/A QLx8262 2.1.5.38 2.0.1.35 2.10.37 9.0.x L1 L3 BCM577xx 7.6.51.0 N/A N/A 6.0.x L1 N/A BCM578xx 7.4.1.0 N/A N/A 6.0.x L1 L1 RedHat Enterprise Linux 5.7 Broadcom BRCM570x 2.6.23 N/A N/A 4.3.6 L3 N/A 5.8 Broadcom BRCM570x 2.7.4.1f N/A N/A 6.0.x L3 N/A QLogic BRMC577xx 2.7.0.3 N/A N/A 6.0.x L3 L3

141 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Operating OS CNA Model Last Vendor Driver Last Boot Last PS OS Array Bf DCB System Version Vendor Code OS S 5.9 Broadcom BRCM5709 2.7.2.2 N/A N/A 7.1.x L1 N/A QLogic BMC578xx 2.7.2.2 N/A N/A 7.1.x L1 N/A 6.1 Emulex OCE10102-i 4.0.323.0 N/A N/A 6.0.x L3 L3 6.2 Broadcom BRCM570x 2.1.11 N/A N/A 6.0.x L3 N/A QLogic BCM577xx 2.1.11 N/A N/A 6.0.x L3 N/A 6.3 QLogic QxE82xx 5.03.01.11 N/A N/A 7.1.x L1 N/A VMware ESX/ESXi 4.0 Broadcom BRCM570x 2.70.1k.v50.2 N/A N/A 6.0.x L3 N/A QLogic BMC577xx 1.8.11t5rc2.8.1-3vmw N/A N/A 6.0.x L3 N/A Emulex OCE10102-i 2.102.525.9 N/A N/A 5.1.x L3 L3 OCE11102-i 2.102.525.9 N/A N/A 5.1.x L3 L3 4.1 Broadcom BRCM570x 2.70.1k.v50.2 N/A N/A 6.0.x L3 N/A

142 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Operating OS CNA Model Last Vendor Driver Last Boot Last PS OS Array Bf DCB System Version Vendor Code OS S VMware QLogic BMC577xx 1.8.11t5rc2.8.1-3vmw N/A N/A 6.0.x L3 N/A Emulex OCx1010x-i 2.102.525.9 N/A N/A 5.1.x L3 N OCx1110x-i 2.102.525.9 N/A N/A 5.1.x L3 L3 5.0 Broadcom BRCM570x 2.72.10.v50.2 N/A N/A 6.0.x L3 N/A QLogic BCM577xx 2.70.1k.v50.2 N/A N/A 6.0.x L3 N/A BCM578xx 2.70.1k.v50.2 N/A N/A 6.0.x L3 L3 Emulex OCe1010x 2.102.525.9 N/A N/A 5.2.x L3 N/A OCe1110x 2.102.525.9 N/A N/A 5.2.x L3 L2 5.1 QLogic BCM578xx 2.710.30.v50.4 7.10.11 7.10.18 8.0.x L1 N/A

C.1.2.2 SW initiators

Vendor iSCSI Initiator/ Operating System Initiator Version PS Series OS Version DCB BfS Microsoft Windows 7 RTM 3.2.8+, 4.x, 5.x, 6.0.x N/A L3 Microsoft Windows Vista RTM 3.2.8+, 4.x, 5.x, 6.0.x N/A L3 Microsoft Windows 2003 2.08 3.2.8+, 4.x, 5.x, 6.0.x N/A L3 Microsoft Windows 2003 R2 5.2.3790.3825 3.2.8+, 4.x, 5.x, 6.0.x N/A L3 Microsoft Windows 2008 6.1.6002.18005 3.2.8+, 4.x, 5.x, 6.0.x N/A L3 SUSE SUSE Linux Enterprise Server 10 2.0-870 3.2.8+, 4.x, 5.x N/A L3 Novell Netware All Versions L3 Oracle Enterprise Linux 5 5.5 4.x, 5.x N/A L3

143 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor iSCSI Initiator/ Operating System Initiator Version PS Series OS Version DCB BfS RedHat RHEL 5 6.2.0.872-13 4.x, 5.x, 6.x N/A L3 VMware ESX 3.5 3.5U5 3.2.8+, 4.x N/A L3 VMware vSphere 4.0 In-Box 4.0.6+, 5.1.x, 5.2.x, 6.0.x N/A L3 VMware vSphere 4.1/ESXi 4.1 In-Box 4.0.6+, 5.1.x, 5.2.x, 6.0.x N/A L3 VMware vSphere 5.0 In-Box 5.1.x, 5.2.x, 6.0.x N/A L3 VMware vSphere 5.1 In-Box 5.1.x, 5.2.x, 6.0.x, 7.0.x, 8.0.x N/A L3

144 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

C.2 Deprecated switches

The switches listed below have been previously tested for use with Dell Storage products, but they are no longer tested by Dell. These switches are supported at Level 2 if the vendor is actively providing support, or at Level 3 if vendor support is no longer available.

C.2.1 SC Series and PS Series

Vendor Model Type Last FW Validated Arista 7148SX Eth EOS4.5.1 Brocade 5100 FC 6.3.0c Brocade B8000/8000e Conv 7.1.x Brocade RX Eth 2.8.x Brocade FGS648P-STK Eth 05.0.1T7e11 Brocade FESX648 Eth 04.2.00T73e2 Brocade FCX648S Eth 06.0.00T7f12 Cisco Catalyst 3750E Family Eth 12.2(35)SE51 Cisco Catalyst 4900M Eth 12.2(40)SG2 Cisco MDS 9124 FC 5.01a Cisco MDS 9128 FC 5.0.4 Cisco M3130G Eth 12.2(50)SE Cisco M3130X Eth 12.2(50)SE Cisco Nexus 50x0 Conv 5.2.x Dell PowerConnect 5424 Eth 2.0.0.43 Dell PowerConnect 5448 Eth 2.0.0.43

145 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Model Type Last FW Validated Dell PowerConnect 62xx Eth 3.3.7.x Dell PowerConnect 8024 Eth 5.1.x Dell PowerConnect 8024F Eth 5.1.x Dell PowerConnect M6220 Eth 5.1.x Dell PowerConnect B-Series 8000/8000e Conv 7.1.x Dell PowerConnect B-Series RX Eth 2.8.x Dell PowerConnect J-Series EX4200 Eth 12.0R1.x Dell PowerConnect J-Series EX4500 Eth 12.0R9.x Dell PowerConnect M8024 Eth 5.1.0.x Extreme Networks X450a-48T Eth 1.0.3.11 HP 3500yl-48G Eth K12.122 Juniper EX4200 Eth 12.0R1.x Juniper EX4500 Eth 12.0R9.x McData 4300 FC 9.9.6.2 McData Sphereon 4400 FC 09.01.00.50 McData Sphereon 4500 FC 9.9.0.16 McData Sphereon 4700 FC 9.01.00.50 McData Intrepid 6064 FC 9.01.00.50 Nortel/Avaya ERS5510-48T Eth 5.0.0.21 QLogic 1400 FC 5.0.1.10.0 QLogic SANBox 5600 FC 7.4.0.16.0

146 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Deprecated devices

Vendor Model Type Last FW Validated QLogic SANBox 5800 FC 7.4.0.16.0

C.2.2 FS Series

Vendor Model Switch FW EqualLogic (FS7xxx) Compellent (FS8600)

Type FS OS Version PS OS Version FS OS Version SCOS Version Dell PowerConnect 62xx Eth 3.3.x 1.0.402 5.2.1 3.0.x 6.4.x Dell PowerConnect 8024/8024F Eth 5.1.x 3.0.8501 7.0.x 3.0.x 6.1.x

147 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM Technical support and additional resources

D Technical support and additional resources

Dell.com/support is focused on meeting customer needs with proven services and support.

Storage technical documents and videos provide expertise that helps to ensure customer success on Dell EMC storage platforms.

D.1 Related documentation

See the following referenced or recommended resources related to this document.

• SC Series, PS Series, and FS Series white papers and videos • SC Series Partner Portal (login required) • PS Series and FS Series configuration guide • PS Series Rapid Configuration Portal

D.2 RPQ process

• The Request for Product Qualification (RPQ) service is a request for approval and support for a non- standard configuration. This service applies specifically to Dell EMC product implementations into non-standard environments. See RPQ Homepage for additional details. https://inside.dell.com/docs/DOC-190638

148 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM