Product Manual: Ultrastar DC HC620 (Hs14) SAS OEM

Total Page:16

File Type:pdf, Size:1020Kb

Product Manual: Ultrastar DC HC620 (Hs14) SAS OEM Hard disk drive specifications Ultrastar® DC HC620 (previously known as Ultrastar Hs14 14TB/15TB) 3.5 inch Serial Attached SCSI hard disk drive Model: HSH721414AL52M0/4 HSH721414AL42M0/4 HSH721415AL52M0/4 HSH721415AL42M0/4 Revision 1.6 31 January 2020 1 Hard Disk Drive Specification Publication Disclaimer Information One MB is equal to one million bytes, one GB is equal to one billion bytes and one TB equals 1,000GB (one trillion bytes) when referring to storage capacity. Accessible capacity will vary from the stated capacity due to formatting and partitioning of the drive, the computer’s operating system, and other factors. The following paragraph does not apply to any jurisdiction where such provisions are inconsistent with local law: THIS PUBLICATION IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. There may be improvements or changes in any products or programs described in this publication at any time. It is possible that this publication may contain reference to, or information about, Western Digital products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Western Digital Corporation intends to announce such Western Digital products, programming, or services in your country. Technical information about this product is available by contacting your local Western Digital product representative or on the Internet at: [email protected]. Western Digital Corporation may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not give you any license to these patents. © 2020 Western Digital Corporation or its affiliates. Western Digital, the Western Digital logo and Ultrastar are registered trademarks or trademarks of Western Digital Corporation or its affiliates in the US and/or other countries. All other marks are the property of their respective owners. References in this publication to Western Digital-branded products, programs, or services do not imply that they will be made available in all countries. Product specifications provided are sample specifications and do not constitute a warranty. Actual specifications for unique part numbers may vary. Please visit the Support section of our website, [email protected], for additional information on product specifications. Pictures shown may vary from actual products. 2 Hard Disk Drive Specification Table of contents 1 General ................................................................................................................................................................ 18 Introduction ..................................................................................................................................... 18 Glossary ........................................................................................................................................... 18 General caution ............................................................................................................................... 19 References ........................................................................................................................................ 19 2 General features .................................................................................................................................................. 20 Part 1. Functional specification ....................................................................................................................... 21 3 Fixed disk subsystem description ....................................................................................................................... 22 Control Electronics ......................................................................................................................... 22 Head disk assembly ........................................................................................................................ 22 Actuator ........................................................................................................................................... 22 4 Drive characteristics ............................................................................................................................................ 23 Default logical drive parameters ................................................................................................... 23 Data sheet ........................................................................................................................................ 25 World Wide Name Assignment ...................................................................................................... 25 Drive organization .......................................................................................................................... 25 Drive Format ............................................................................................................................ 25 Cylinder allocation................................................................................................................... 25 Zone Layout .............................................................................................................................. 26 Performance characteristics ........................................................................................................... 28 Command overhead ................................................................................................................. 28 Mechanical positioning ............................................................................................................ 29 Drive ready time ...................................................................................................................... 29 Operating modes ...................................................................................................................... 30 5 Defect flagging strategy ....................................................................................................................................... 31 Shipped format ................................................................................................................................ 31 6 Specification ........................................................................................................................................................ 32 Electrical interface .......................................................................................................................... 32 Connector location ................................................................................................................... 32 29 pin Serial Attached SCSI (SAS) Connector Definition .................................................... 33 Voltage and Ground Signals ................................................................................................... 34 Ready LED output ................................................................................................................... 34 Environment .................................................................................................................................... 35 Temperature and humidity ..................................................................................................... 35 Storage Requirements ............................................................................................................. 36 Corrosion test ........................................................................................................................... 36 Atmospheric condition ............................................................................................................. 36 DC power requirements.................................................................................................................. 37 Input voltage ............................................................................................................................ 37 Power supply current (typical1) .............................................................................................. 38 Power line noise limits ............................................................................................................ 39 Power Consumption Efficiency ............................................................................................... 39 Reliability ........................................................................................................................................ 40 Data integrity ........................................................................................................................... 40 Cable noise interference .......................................................................................................... 40 Load/Unload ............................................................................................................................. 40 Start/stop cycles ....................................................................................................................... 40 Preventive maintenance
Recommended publications
  • Clustered Data ONTAP® 8.3 SAN Configuration Guide
    Updated for 8.3.1 Clustered Data ONTAP® 8.3 SAN Configuration Guide NetApp, Inc. Telephone: +1 (408) 822-6000 Part number: 215-10114_A0 495 East Java Drive Fax: +1 (408) 822-4501 June 2015 Sunnyvale, CA 94089 Support telephone: +1 (888) 463-8277 U.S. Web: www.netapp.com Feedback: [email protected] Table of Contents | 3 Contents Considerations for iSCSI configurations .................................................... 5 Ways to configure iSCSI SAN hosts with single nodes .............................................. 5 Ways to configure iSCSI SAN hosts with HA pairs ................................................... 7 Benefits of using VLANs in iSCSI configurations ..................................................... 8 Static VLANs .................................................................................................. 8 Dynamic VLANs ............................................................................................. 9 Considerations for FC configurations ...................................................... 10 Ways to configure FC SAN hosts with single nodes ................................................. 10 Ways to configure FC with HA pairs ........................................................................ 12 FC switch configuration best practices ..................................................................... 13 Supported number of FC hop counts ......................................................................... 13 Supported FC ports ...................................................................................................
    [Show full text]
  • FICON Native Implementation and Reference Guide
    Front cover FICON Native Implementation and Reference Guide Architecture, terminology, and topology concepts Planning, implemention, and migration guidance Realistic examples and scenarios Bill White JongHak Kim Manfred Lindenau Ken Trowell ibm.com/redbooks International Technical Support Organization FICON Native Implementation and Reference Guide October 2002 SG24-6266-01 Note: Before using this information and the product it supports, read the information in “Notices” on page vii. Second Edition (October 2002) This edition applies to FICON channel adaptors installed and running in FICON native (FC) mode in the IBM zSeries procressors (at hardware driver level 3G) and the IBM 9672 Generation 5 and Generation 6 processors (at hardware driver level 26). © Copyright International Business Machines Corporation 2001, 2002. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Notices . vii Trademarks . viii Preface . ix The team that wrote this redbook. ix Become a published author . .x Comments welcome. .x Chapter 1. Overview . 1 1.1 How to use this redbook . 2 1.2 Introduction to FICON . 2 1.3 zSeries and S/390 9672 G5/G6 I/O connectivity. 3 1.4 zSeries and S/390 FICON channel benefits . 5 Chapter 2. FICON topology and terminology . 9 2.1 Basic Fibre Channel terminology . 10 2.2 FICON channel topology. 12 2.2.1 Point-to-point configuration . 14 2.2.2 Switched point-to-point configuration . 15 2.2.3 Cascaded FICON Directors configuration. 16 2.3 Access control. 18 2.4 Fibre Channel and FICON terminology.
    [Show full text]
  • Fibre Channel and Iscsi Configuration Guide for the Data ONTAP® 8.0 Release Family
    Fibre Channel and iSCSI Configuration Guide for the Data ONTAP® 8.0 Release Family NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web: www.netapp.com Feedback: [email protected] Part number: 215-08164_A0 August 2013 Table of Contents | 3 Contents iSCSI configurations .................................................................................... 6 Single-network HA pair in an iSCSI SAN .................................................................. 6 Multi-network HA pair in an iSCSI SAN ................................................................... 7 Direct-attached single-controller configurations in an iSCSI SAN ............................ 8 VLANs for iSCSI configurations ................................................................................ 9 Static VLANs ................................................................................................ 10 Dynamic VLANs ........................................................................................... 10 Fibre Channel configurations .................................................................... 11 FC onboard and expansion port combinations .......................................................... 11 Fibre Channel supported hop count .......................................................................... 12 Fibre Channel supported speeds ................................................................................ 13 Fibre Channel switch
    [Show full text]
  • IT Acronyms.Docx
    List of computing and IT abbreviations /.—Slashdot 1GL—First-Generation Programming Language 1NF—First Normal Form 10B2—10BASE-2 10B5—10BASE-5 10B-F—10BASE-F 10B-FB—10BASE-FB 10B-FL—10BASE-FL 10B-FP—10BASE-FP 10B-T—10BASE-T 100B-FX—100BASE-FX 100B-T—100BASE-T 100B-TX—100BASE-TX 100BVG—100BASE-VG 286—Intel 80286 processor 2B1Q—2 Binary 1 Quaternary 2GL—Second-Generation Programming Language 2NF—Second Normal Form 3GL—Third-Generation Programming Language 3NF—Third Normal Form 386—Intel 80386 processor 1 486—Intel 80486 processor 4B5BLF—4 Byte 5 Byte Local Fiber 4GL—Fourth-Generation Programming Language 4NF—Fourth Normal Form 5GL—Fifth-Generation Programming Language 5NF—Fifth Normal Form 6NF—Sixth Normal Form 8B10BLF—8 Byte 10 Byte Local Fiber A AAT—Average Access Time AA—Anti-Aliasing AAA—Authentication Authorization, Accounting AABB—Axis Aligned Bounding Box AAC—Advanced Audio Coding AAL—ATM Adaptation Layer AALC—ATM Adaptation Layer Connection AARP—AppleTalk Address Resolution Protocol ABCL—Actor-Based Concurrent Language ABI—Application Binary Interface ABM—Asynchronous Balanced Mode ABR—Area Border Router ABR—Auto Baud-Rate detection ABR—Available Bitrate 2 ABR—Average Bitrate AC—Acoustic Coupler AC—Alternating Current ACD—Automatic Call Distributor ACE—Advanced Computing Environment ACF NCP—Advanced Communications Function—Network Control Program ACID—Atomicity Consistency Isolation Durability ACK—ACKnowledgement ACK—Amsterdam Compiler Kit ACL—Access Control List ACL—Active Current
    [Show full text]
  • Metroha Administration Guide
    MetroHA Administration Guide Date: May, 2016 Subject: MetroHA Administration Guide Software: NexentaStor Software Version: 4.0.4 Part Number: 3000-nxsmetro-000001-A Copyright © 2016 Nexenta Systems, ALL RIGHTS RESERVED www.nexenta.com MetroHA Administration Guide Copyright © 2016 Nexenta SystemsTM, ALL RIGHTS RESERVED Notice: No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose, without the express written permission of Nexenta Systems (hereinafter referred to as “Nexenta”). Nexenta reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. Nexenta products and services only can be ordered under the terms and conditions of Nexenta Systems’ applicable agreements. All of the features described in this document may not be available currently. Refer to the latest product announcement or contact your local Nexenta Systems sales office for information on feature and product availability. This document includes the latest information available at the time of publication. Nexenta, NexentaStor, NexentaEdge, and NexentaConnect are registered trademarks of Nexenta Systems in the United States and other countries. All other trademarks, service marks, and company names in this document are properties of their respective owners. This document applies to the following product versions: Product Versions supported NexentaStor 4.0.4-FP5 or later ATTO FibreBridge 6500 1.18 or later Copyright © 2016 Nexenta Systems, ALL RIGHTS RESERVED ii www.nexenta.com MetroHA Administration Guide Contents 1 MetroHA Overview . .1 What is MetroHA? .
    [Show full text]
  • Intrepid 3800 Enterprise
    2.5” Solid -State Intrepid 3800 Drive Enterprise SSD IT3RSK41ET3XX-xxxx The OCZ 2.5” Intrepid 3000 Series of Solid State Drives are designed specifically to address Enterprise storage and computing applications where demanding performance, reliability, and the total cost of SSD Datasheet ownership (TCO) are major factors. Intrepid 3800 2.5 Inch Solid-State Drive OCZ Intrepid 3800 SATA Solid State Drive Part Number Description UPC IT3RSK41ET330-0100 OCZ Intrepid 3800 2.5” SATA III 100GB 842024034407 IT3RSK41ET330-0200 OCZ Intrepid 3800 2.5” SATA III 200GB 842024034414 IT3RSK41ET340-0400 OCZ Intrepid 3800 2.5” SATA III 400GB 842024034421 IT3RSK41ET350-0800 OCZ Intrepid 3800 2.5” SATA III 800GB 842024034445 2 Released December , 2014 OCZ Storage Solutions reserves the right to change products or spe cifications without notice. OCZ CONFIDENTIAL 2014 OCZ Storage Solutions - A Toshiba Group Company All rights reserved. Intrepid 3800 2.5 Inch Solid-State Drive Product Specifications Available in 2.5” Form Factor Temperature SATA III / 6Gb/s Interface – Operating 6: 0°C to 70°C Capacity: 100GB, 200GB, 400GB and 800GB – Non-Operating: -45°C to 85°C Components: 19nm eMLC NAND Flash Memory – Temperature monitoring and logging Security: AES 256-bit Encryption Reliability Bandwidth Performance Specifications 1,3,4 – Mean Time Between Failures (MTBF) – Sustained Sequential Read: 500 MB/s 2 Million Hours – Sustained Sequential Write: 450 MB/s Endurance Rating – 4 DWPD Read and Write IOPS specifications (Full LBA Range, – 100GB: 730 TBW Iometer*Queue
    [Show full text]
  • 8.2 Data ONTAP SAN Configuration Guide for 7-Mode
    Data ONTAP® 8.2 SAN Con®guration Guide For 7-Mode July 2016 | 215-08974_C0 [email protected] Updated for 8.2.2 Table of Contents | 3 Contents iSCSI configurations .................................................................................... 5 Single-network and multi-network single-controller configuration in an iSCSI SAN ....................................................................................................................... 5 Single-network HA pair in an iSCSI SAN .................................................................. 6 Multi-network HA pair in an iSCSI SAN ................................................................... 6 Direct-attached single-controller configurations in an iSCSI SAN ............................ 7 VLANs for iSCSI configurations ................................................................................ 8 Static VLANs .................................................................................................. 9 Dynamic VLANs ............................................................................................. 9 Fibre Channel configurations .................................................................... 10 Recommended number of paths to avoid single points of failure ............................. 10 FC supported hop counts ........................................................................................... 10 FC supported speeds .................................................................................................. 11 FC switch configuration
    [Show full text]
  • Configuring Fibre Channel Storage Arrays
    Dell PowerVault MD Series Fibre Channel Storage Array Configuring Fibre Channel With Dell MD3600f/3620f/ MD3660f Series Storage Arrays Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2012 Dell Inc. Trademarks used in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are trademarks of Dell Inc. Intel®, Pentium®, Xeon®, Core® and Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD® is a registered trademark and AMD Opteron™, AMD Phenom™ and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, Internet Explorer®, MS-DOS®, Windows Vista® and Active Directory® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat® and Red Hat® Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® and SUSE® are registered trademarks of Novell Inc. in the United States and other countries. Oracle® is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware®, Virtual SMP®, vMotion®, vCenter® and vSphere® are registered trademarks or trademarks of VMware, Inc.
    [Show full text]
  • Pm871b M.2 SSD Datasheet V1.1 for General.Book
    SAMSUNG CONFIDENTIAL Rev. 1.01. Jul. 2017 MZNLN1T0HALR-00000/07 MZNLN512HAJQ-00000/07 MZNLN256HAJQ-00000/07 MZNLN128HAHQ-00000/07 M.2 SATA 6Gbps PM871b SAMSUNG Solid State Drive datasheet SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE. Products and specifications discussed herein are for reference purposes only. All information discussed herein is provided on an "AS IS" basis, without warranties of any kind. This document and all information discussed herein remain the sole and exclusive property of Samsung Electronics. No license of any patent, copyright, mask work, trademark or any other intellectual property right is granted by one party to the other party under this document, by implication, estoppel or other- wise. Samsung products are not intended for use in life support, critical care, medical, safety equipment, or similar applications where product failure could result in loss of life or personal or physical harm, or any military or defense application, or any governmental procurement to which special terms or provisions may apply. For updates or additional information about Samsung products, contact your nearest Samsung office. All brand names, trademarks and registered trademarks belong to their respective owners. ⓒ 2017 Samsung Electronics Co., Ltd. All rights reserved. - 1 - SAMSUNG CONFIDENTIAL MZNLN1T0HALR-00000/07 Rev. 1.01 MZNLN512HAJQ-00000/07 MZNLN256HAJQ-00000/07 datasheet MZNLN128HAHQ-00000/07 SSD Revision History Revision No. History Draft Date Remark Editor Review by 0.1 1. Initial release. Mar. 22, 2017 Target S.J. Oh S.W. Park 1. TCG Opal compliant (-00007 only). 2. Unused commands removed at Table 12, Table 15, ID Data, Informa- tion changed.
    [Show full text]
  • Storage Area Network (SAN) Security and Performance
    MASTER THESIS Evaluation of Storage Area Network (SAN) Security and Performance Master Thesis in Computer Network Engineering November 2013 Author: Siavash Hajirostam Supervisor: Tony Larsson Examiner: Tony Larsson __________________________________ School of Information Science, Computer and Electrical Engineering Halmstad University PO Box 823, SE-301 18 HALMSTAD Sweden Evaluation of Storage Area Network (SAN) Security and Performance Siavash Hajirostam © Copyright Siavash Hajirostam, 2013. All rights reserved. Master thesis report IDE 1325 School of Information Science, Computer and Electrical Engineering Halmstad University Preface I would like to express my appreciation to my supervisor, Professor Tony Larsson, for the many useful discussions, comments and suggestions on this thesis and also my thanks go to the staff of Halmstad University for giving me the opportunity to study in the computer network engineering program. Finally, my special thanks to my family for their encouragement and support during my stud ies. Siavash Hajirostam Halmstad, November 2013 i Abstract Due to growing the number of Information Technology (IT) users all around the world, consequently the amount of data that needs to be stored is increasing day by day. Single attached disks and old storage technologies cannot manage the storing these amounts of data. Storage Area Network (SAN) is a distributed storage technology to manage the data from several nodes in centralize place and secure. This thesis investigates how SAN works, the file system and protocols that are used in implementation of SAN. The thesis also investigate about other storages technologies such as Network Attached Storage (NAS) and Direct Attached Storage (DAS) to figure out the advantages and disadvantages of SAN , The main focus of the thesis project is on identifying the security vulnerabilities in SAN such as possible attacks in different SAN protocols.
    [Show full text]
  • Mac OS X Fibre Channel Connectivity to the HP Storageworks Enterprise Virtual Array Storage System Configuration Guide
    Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Part number: 5697-0025 Third edition: July 2009 Legal and notice information © Copyright 2007, 2009 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Intel is a trademark of Intel Corporation or its subsidiaries in the U.S. and other countries. Apple and the Apple logo are trademarks of Apple Computer, Inc., registered in the U.S. and other countries. Java is a US trademark of Sun Microsystems, Inc. Contents About this guide ................................................................................... 7 Intended audience ...................................................................................................................... 7 Related documentation ...............................................................................................................
    [Show full text]
  • SCSI Commands Reference Manual
    SCSI Commands Reference Manual Fibre Channel (FC) Serial Attached SCSI (SAS) 100293068, Rev. J October 2016 © 2016 Seagate Technology LLC. All rights reserved. Publication number: 100293068, Rev. J October 2016 Seagate, Seagate Technology and the Spiral logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. SeaTools is a trademarks of Seagate Tech- nology LLC or one of its affiliated companies in the United States and/or other countries. All other trademarks or registered trademarks are the property of their respective owners. No part of this publication may be reproduced in any form without written permission of Seagate Technology LLC. Call 877-PUB-TEK1 (877-782-8351) to request permission. Contents 1. Definitions, Symbols, Abbreviations, Keywords, And Conventions. 24 1.1 Definitions . .25 1.2 Symbols and abbreviations . .33 1.3 Keywords . .35 1.4 Conventions. .36 2. General Concepts . 37 2.1 Command Descriptor Block (CDB) . .37 2.1.1 CDB usage and structure . .37 2.1.2 The fixed length CDB formats. .38 2.1.3 The variable length CDB formats. .40 2.2 Common CDB fields . .42 2.2.1 Operation Code. .42 2.2.2 SERVICE ACTION . .42 2.2.3 Logical block address . .43 2.2.4 TRANSFER LENGTH. .43 2.2.5 PARAMETER LIST LENGTH . .43 2.2.6 ALLOCATION LENGTH . .43 2.2.7 CONTROL . .44 2.2.8 Grouping function . .44 2.3 Parameter Rounding. .45 2.4 Sense data . .46 2.4.1 Sense data introduction . .46 3. Direct Access Block commands (SPC-5 and SBC-4) .
    [Show full text]