1922

Products by Technometal Hellas Information, Warranty, Transportation, Storage, installation, Use & Maintenance instructions.

CERTIFICATION

The Factory Production Control Certificate Number DOP - 1922-CPR-0953 From 21/12/2007 to 21/12/2017 Materialprüfungsamt Nordrhein-Westfalen Marsbruchstrabe 186 (Notified Body No. 1922)

Ch. Chaviaris - D. Papadios & Co Metal Products Industry 1922 Construction of Chimneys and Components Factory: 20th km , P.O. 127, P.C. 57200, Langadas Thessaloniki Phone: +30 23940 61275, +30 23940 61504, Fax: +30 23940 61094 www.technometalhellas.gr e-mail: [email protected]

DECLARATION OF CONFORMITY & PRODUCT INFORMATION

Requirements for metal chimneys Part 1: System chimney products DIN EN 1856-1:2009 Commercial name: TechnoGas CE®

Person in change: Dimitris Papadios

Number Certificate: 1922 - CPR - 0953

Date of Publication: 21.12.2017

Product: Double Wall, Chimney System and Fittings, Stainless Steel 1.4301 - AISI 304 BA - Thicknesses ≥ 0,40 mm

Identification of accompanying documentation to EN 1856-1

Metal chimneys, with silicone gasket: EN 1856-1, T200, P1, W, V2, L20 (40-50), G(50), Ø80/130-300/350 Metal chimneys, without silicone gasket: EN 1856-1, T600, N1, D, V2, L20 (40-50), G(70), Ø80/130-300/350

Product

Standard Number

Temperature Lavel

Pressure Lavel (N1-Negative, P1-Positive)

Condensate Resistance (W: wet - D: dry)

Corrocion Resistance Class

Flue Liner Material Specification and Thickness in (mm)

Sootfire Resistance (G: yes - O: no) Distance to combustible material in (mm)

Nominal diameter (Ø) (inner tube) in mm

Properties of a multi-wall metal chimney system

Compressive strength: Maximum load (Installing instructions) Flow resistance: Average roughness: 1,0 mm, Zeta-values according to DIN EN 13384-1 (Installing instructions) Thermal resistance: 0,501 m²K/W Flexural strength angular assembly: Maximum length between two supports: 3m at 90° Tensile strength: (Installing instructions) Wind load: free standing end above last fixation: ≤ 2m up to Ø500 mm (Installing instructions) Maximum distance between vertical supports: 2m Freeze-thaw resistance: Yes Cleaning: The chimney system may only be cleaned by a SPECIALIZED PERSONNEL.

Page: 1 Ch. Chaviaris - D. Papadios & Co Metal Products Industry 1922 Construction of Chimneys and Components Factory: 20th km Thessaloniki – Serres, P.O. 127, P.C. 57200, Langadas Thessaloniki Greece Phone: +30 23940 61275, +30 23940 61504, Fax: +30 23940 61094 www.technometalhellas.gr e-mail: [email protected]

DECLARATION OF CONFORMITY & PRODUCT INFORMATION

Requirements for metal chimneys Part 1: System chimney products DIN EN 1856-1:2009 Commercial name: TechnoGas CE®

Person in change: Dimitris Papadios

Number Certificate: 1922 - CPR - 0953

Date of Publication: 21.12.2017

Product: Double Wall, Chimney System and Fittings, Stainless Steel 1.4404 - AISI 316 L - Thicknesses ≥ 0,40 mm

Identification of accompanying documentation to EN 1856-1

Metal chimneys, with silicone gasket: EN 1856-1, T200, P1, W, V2, L50 (40-50), G(50), Ø80/130-300/350 Metal chimneys, without silicone gasket: EN 1856-1, T600, N1, D, V2, L50 (40-50), G(70), Ø80/130-300/350

Product

Standard Number

Temperature Lavel

Pressure Lavel (N1-Negative, P1-Positive)

Condensate Resistance (W: wet - D: dry)

Corrocion Resistance Class

Flue Liner Material Specification and Thickness in (mm)

Sootfire Resistance (G: yes - O: no) Distance to combustible material in (mm)

Nominal diameter (Ø) (inner tube) in mm

Properties of a multi-wall metal chimney system

Compressive strength: Maximum load (Installing instructions) Flow resistance: Average roughness: 1,0 mm, Zeta-values according to DIN EN 13384-1 (Installing instructions) Thermal resistance: 0,501 m²K/W Flexural strength angular assembly: Maximum length between two supports: 3m at 90° Tensile strength: (Installing instructions) Wind load: free standing end above last fixation: ≤ 2m up to Ø500 mm (Installing instructions) Maximum distance between vertical supports: 2m Freeze-thaw resistance: Yes Cleaning: The chimney system may only be cleaned by a SPECIALIZED PERSONNEL.

Page: 2

Product Information According to EN 1856-1

Declaration of performance (DOP)

DOP - No. 1922-CPR-0953/ 21.12.2017

1. Unique identification code of the product-type: Multi-wall chimney system type TechnoGas 304 CE® or TechnoGas 316 CE® according EN 1856-1:2009

2. Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4): Twin wall chimney Gas system type. TechnoGas 304 CE® Internal wall material: Stainless Steal No: 1.4301 (304), Thicknesses ≥ 0,40 mm Metal chimneys, with silicone gasket Model 1: (Ø80/130-300/350) EN 1856-1, T200, P1, W, V2, L20 (40-50), G(40) Manufacturer product identification. Metal chimneys, without® silicone gasket Model 1: (Ø80/130-300/350) EN 1856-1, T600, N1, D, V2, L20 (40-50), G(70) Manufacturer product identification. TechnoGas 316 CE Internal wall material: Stainless Steal No: 1.4404 (316), Thicknesses ≥ 0,40 mm nternal wall material: Stainless Steal No: 1.4301 (304), Thicknesses ≥ 0,40 mm Metal chimneys, with silicone gasket Model 1: (Ø80/130-300/350) EN 1856-1, T200, P1, W, V2, L50 (40-50), G(40) Manufacturer product identification. Metal chimneys, without silicone gasket Model 1: (Ø80/130-300/350) EN 1856-1, T600, N1, D, V2, L50 (40-50), G(70) Manufacturer product identification.

3. Intended use or uses of the construction product, in accordance with the applicable harmonised Technical specification, as foreseen by the manufacturer: Convey the products of combustion from heating appliances to the outside atmosphere.

4. Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5): Ch. Chaviaris - D. Papadios & Co Metal Products Industry Construction of Chimneys and Components Factory: 20th km Thessaloniki – Serres, P.O. 127, P.C. 57200, Langadas Thessaloniki Greece Phone: +30 23940 61275, +30 23940 61504, Fax: +30 23940 61094 www.technometalhellas.gr e-mail: [email protected]

5. Where applicable, name and contact address of the authorised representative whose mandate covers he tasks specified in Article 12 (2): Not applicable

6. System or systems of assessment and verification of constancy of performance of the construction product as set out in CPR, Annex V: System 2+ and System 4

7. In case of the declaration of performance concerning a construction product for which a European Technical Assessment has been issued: Notified factory production control certification body no.1922 performed the initial Inspection of the manufacturing plant and of factory production control and the continuous surveillance, assessment and evaluation of factory production control and issued the certificate of conformity 1922-CPR-0953/21.12.2017 the factory production control.

Page: 3

Product Information According to EN 1856-1

8. Essential Characteristics Performance Harmonized technical specification

8.1 Compressive strength Sections and fittings: EN 1856-1:2009 Model 1 to 2 DN (80/130-300/350): up to 38 m Chimney sections, fittings and supports Model 1 to 2 DN (350/400-400/450): up to 32 m Supports: n.p.d. For further information see the installation instruction Chimney

8.2 Resistance to fire (Resistance to fire from inside to outside) Model EN 1856-1:2009 1 to 2 DN (80/130-300/350): T200 – G(50) Tested without fully enclosed and with ventilated floors.

8.3 Gas tightness/leakage Model 1 DN DN (80/130-300/350): P1 EN 1856-1:2009 Model 2 DN DN (80/130-300/350): P1

8.4 Flow resistance of chimney sections, According to EN 13384-1 EN 1856-1:2009 fittings and terminals Component: (Zeta-value) Single resistance Pipe tee 87°: 1,14 Pipe tee 45°: 0,35 Pipe bend 87°: 0,40 Pipe bend 45°: 0,28 Pipe bend 30°: 0,20 Pipe bend 15°: 0,10 Terminals: (only for operation in negative pressure) Rain cap: 1,0 Fin cap type „Hubo“: ≤ Ø140 mm 0,1/ ≥ Ø150 mm 0,2 Wind deflector: ≤ Ø140 mm 0,1/ ≥ Ø150 mm 0,2 Hurrican: 0,1

8.5 Thermal resistance Model 1 to 2 DN (80/130-300/350): 0,501m²K/W EN 1856-1:2009 tested at 200°C

Thermal shock resistance Model 1 to 2 DN DN (80/130-300/350): EN 1856-1:2009

8.6 Soot fire resistance No2) Because designated O

8.7 Thermal performance under normal Model 1 to 2 DN DN (80/130-300/350): T200 operating conditions

8.8 Flexural tensile strength Model 1 to 2 DN (80/130-300/350): up to 13m EN 1856-1:2009

(only for means of connection for chimney sections and fittings)

8.9 Non vertical installation Model 1 to 2 DN (80/130-300/350): EN 1856-1:2009 Maximum offset between supports 3m at 90° (maximum distance between two fixations, supports at non vertical installation)

8.10 Components subject to wind load Model 1 to 2 DN (80/130-300/350): EN 1856-1:2009 Free standing height 2m above last support. Maximum spacing between lateral supports: 2m.

Page: 4

Product Information According to EN 1856-1

Essential Characteristics Performance Harmonized technical specification

Durability: EN 1856-1:2009

8.11 Water and vapour diffusion resistance Model 1 to 2 DN (80/130-300/350): Yes (*)

8.12 Condensate penetration resistance Model 1 to 2 DN (80/130-300/350): Yes(*)

8.13 Against corrosion Model 1 to 2 DN (80/130-300/350): V2(*)

8.14 Freeze thaw resistance Model 1 to 2 DN (80/130-300/350): Yes(*)

9. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 8. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4.

Signed for and on behalf of the manufacturer by:

Thessaloniki, 09 July 2019 Head Manager CEO: Dimitris Papadios

Page:: 513 Chr. Chaviaris - Dim. Papadios & CO. G.P. Metal Products Industry Construction of Air Ducts, Chimneys and Components Factory: 20th km Thessaloniki - Serres 57200, P.O. BOX 127 Langadas, Thessaloniki Greece Phone: +30 23940 61275, +30 23940 61504 Fax: +30 23940 61094 e-mail: [email protected] - www.technometalhellas.gr