The Control Panel Monodraught Cylon control panels can provide the control features described overleaf, to serve several zones or rooms independently. For Putting the wind and sun to work -based control, one or more temperature sensors are positioned in each control zone or room to provide an for free natural ventilation average input. The manual override buttons are incorporated on the temperature sensors themselves.

The controls package normally includes all sensors and Advantages commissioning. Maintenance – Virtually zero maintenance, since Each Cylon control panel measures 400mm x 300mm x systems are manufactured in GRP, which will last 200mm deep and can be located in a separate room to the the life of the building and requires no continual area to be controlled, such as a plant control room. The power maintenance as compared to metal or timber requirement is 230V AC, isolated to a 5A fused spur. products.

The Cylon control panel does have the facility for other various Running and Energy Costs – Virtually zero. The only options, such as CO2 sensors or air quality sensors and power required is for operating the modulating generally, the panel incorporates a relay and dampers. interlock but, as you can appreciate, everything revolves on price. We, therefore, try to offer the most cost effective Night Time – Provides all the benefits of automatic control system commensurate with low cost. free night time cooling without compromising the security of the building. These settings are recommended for our standard temperature based control approach but can be reprogrammed to suit Environmentally Friendly – Since individual sites and we would always be pleased to discuss utilise the wind and thermal buoyancy, they are the individual requirements on a Project by Project approach. very epitome of . Semi-automatic and manual based controls Design Freedom – Monodraught offer a wide range Daimler , Milton Keynes A separate leaflet has been produced for semi-automatic and of exciting, standard designs but can also offer manual based control systems. bespoke systems to suit the building We do hope the above points have been of assistance in Health – Many people dislike Monodraught forming a better understanding of the Monodraught systems, which they claim produces dry air and Advantages of the natural ventilation system. If you require any can circulate germs. further information, please contact our Technical Design Department. Healthier – Windcatcher systems take their air from above roof level, which is considered to be relatively Natural Ventilation System free from dust, dirt and traffic pollution, as compared to low level air intakes. Interior view of We have often been asked to set out More Space – Since Windcatchers eliminate the Daimler Chrysler the advantages of the Windcatcher offices. systems as compared to air need for air conditioning, this frees up space usually conditioning systems. required for . Many of the points that we make may Security – No-one can break in through a be considered by some as rather Windcatcher system! contentious and their relevance will Windows – In summer months, openable windows apply in varying degrees to your will always add to the cross ventilation but can be particular Project. closed and made secure during night time, since the We also recognise that there are Windcatcher system will provide all necessary limitations on the application of any night time cooling. natural ventilation system, which must SunCatchers – Monodraught Windcatchers can be also be taken into account in this presentation. combined with the remarkable SunPipe system to provide natural ventilation and natural daylight in In general terms, natural ventilation one complete package. has been welcomed as a cost effective, energy saving and Guarantee – 25-year guarantee on Monodraught environmentally friendly approach, to systems with a life expectancy of 35 years. provide an alternative to mechanically After Sales Service – Monodraught provide a free driven air conditioning systems. 12 month operational check and cleaning service We do hope that the following points Halifax House, Cressex Business Park, High Wycombe, within a 300 miles radius of High Wycombe. will be of assistance in forming a Nov 2004 Buckinghamshire HP12 3SE Thereafter, a ten year annual maintenance contract better understanding of the Tel: 01494 897700 Fax: 01494 532465 is provided at a nominal cost. Monodraught Windcatcher natural email: [email protected] www.monodraught.com ventilation systems. Although there may be limitations on the application of natural ventilation Advantages of Natural Ventilation Systems Control of Natural Ventilation Systems Control Settings (based on temperature) systems, in general terms we consider they offer considerable advantages Three settings are provided for automatic operation to cover •Where Windcatcher systems are used, fresh air is drawn from Whereas natural ventilation has seen tremendous increase in over the application of air conditioning systems. applications over the last ten years, one of the early criticisms the following 'seasons':- above roof level, which is relatively clean and free from Summer June - August contamination, as compared to the dust, dirt and pollutants from Architects and Clients was that the principles of design and application were fine but they generally felt disappointed Winter November - March Some of the Disadvantages of Air Conditioning that are more prevalent at ground level. Spring/Autumn April - May Systems as compared to Natural Ventilation that the explanation of the control of natural ventilation was either too complicated, too sophisticated or conversely, in September - October • In some cases, people have complained that air conditioned •It is generally considered by most staff that the down flow many cases, was non-existent at all! Where there have been offices can lead to soreness of the eyes, dryness in the of fresh air from the Windcatcher system can be very Summer Program changes of staff or personnel in a building and indeed, when Up to 16°C Dampers remain closed throat, and other forms of mild discomfort. refreshing and welcome on a hot summer’s day and highlights the building is initially occupied, it is vital that the responsibility At 17°C Dampers 20% open the Monodraught principle of ‘bringing the outdoors, indoors’. for this information passes from the Contractor to the Client. • In severe cases, this has lead to SBS (). At 18°C Dampers 40% open The end user, therefore, requires a control system that provides The exact causes of SBS are still not fully understood but it At 19°C Dampers 60% open •Where openable windows are installed, staff can still open a refined control yet is simple to use and understand. is considered it is probably a combination of several factors windows if they wish, since this does not have any detri- At 20°C Dampers 80% open At 21°C Dampers fully open of the recirculation of stale air; the implicit need for the mental effect on the operation of the Windcatcher systems. We recognise that there can sometimes be quite a difference regular cleaning of all filters, both on the fresh air intake and between the design usage of a building (which is often Night time cooling is incorporated in the programming, so as to on filtering the recirculation of • Windcatchers can be used to designed at a quite early stage) and the actual usage, which drive the dampers fully open from midnight to 6am. polluted air, plus concerns on the advantage throughout the year, even can be somewhat different to original design of the system, during the winter months, when it is the original Designer’s Spring/Autumn Program which can vary from one firm to generally recommended that the thoughts. Accordingly, we Up to 19°C Dampers remain closed another. Windcatcher dampers remain consider that with all natural At 20°C Dampers 20% open 5% open, so as to allow background ventilation Projects, provision At 24°C Dampers fully open • Whereas air conditioning systems trickle ventilation. This allows warm, should be made within the require regular maintenance, the Contract, to ‘revisit’ the site Note: Night time cooling does not form part of stale air to escape but also brings a general consensus is that it must or Project, say three months the spring/autumn program. constant supply of fresh air into the be preferable to bring in fresh air after occupation has been working space. The separate section Winter Program from outside rather than recirculate completed, to ‘fine tune’ the We recognise that far less natural ventilation the internal air. on controls details the wide scope of control strategy in accordance is required in the winter and, therefore, the the control strategy for Windcatcher with the end user’s wishes. • Some people consider that the systems, which can bring air quality, following settings are recommended. recirculation of air within an office , and a variety of other The control of the natural Up to 22°C Dampers remain closed or can can give rise to the spread of control options into play. ventilation systems can, of be set to 5% open to provide germs and infections although this course, be linked to the trickle ventilation is not proven. Night Time Cooling building's BEM system but At 23°C Dampers 20% open otherwise, control of the • Many people find that the ‘thermal • This is probably the most important system is via our own The Override Facility shock’ of working in an artificially aspect of natural ventilation systems, separate control panel. which air conditioning systems do The override facility is designed to enable the cooled space, having walked in end user to open the dampers fully when not possess. from a warm summery day, can Monodraught's Controls additional ventilation is required. The end user lead to summer colds and minor Philosophy may also wish to close the dampers if there is • At midnight, regardless of ailments. The control system installed too much ventilation. temperature, the dampers open fully to allow any build up of provides a fully automatic One distinct push on the override will drive • The imposition of air conditioned offices results in a ‘one size warm stale air to rise up through the Windcatcher segments system and is not dependent the dampers fully open. The dampers will fits all’ scenario with some people feeling too cold and others and be expelled to the outside air. At the same time, the cool on input from the end user remain open for one hour in the Summer, finding it not cool enough! As a result, this can sometimes night air will descend to replace the warm air that rises up during day-to-day use. At the 40 minutes in the Spring/Autumn, and lead to personal irritation and discomfort. through the Windcatcher system. same time, we recognise that 20 minutes in the Winter. At the end of that the system must allow the designated period, the dampers will • Air conditioning systems use certain , which •This incoming air is also assisted by any external air end user to be involved (by automatically revert to their programmed in the long term have been considered harmful to our movement, which is encapsulated by the air intakes of the the use of manual overrides) position, normally based on temperature. environment and there is therefore a general government Windcatcher system, slightly pressurising the space below and then for the system to revert to its pre-programmed policy to reduce the use of such by at least and encouraging the outflow of the warmer stale air from the settings, so as to comply with the overall control strategy. The principle of the Spring/Autumn override facility is to take 20% over the forthcoming years. building. account of unusual weather conditions, such as an 'Indian For smooth temperature control, the natural ventilation system Summer' or a warm spring day. • Air conditioning systems are energy dependent, using up •The night time cooling program is based on BSRIA Technical needs to provide a proportional response to conditions within . If for any reason, the air conditioning systems Note TN11/95. This allows the building's structure and fabric the room. This is usually achieved by the dampers opening Two distinct pushes will fully close the dampers for the should break down or the power supply should fail, there is override period. If the end user wishes to cancel the override to be saturated with cool air during the night time period, progressively as the increases and no back up procedure and the buildings will then instruction, then a third distinct push will send a signal to the thereby increasing the building's capacity to absorb proportionately closing as the room temperature decreases. automatically overheat. Furthermore, the space required for control panel to take the dampers back to their original pre- during the day. the chillers and equipment itself impacts on the building Each of the seasons requires a slightly different approach, programmed position. design and layout, often taking up valuable space that can although it has to be stressed that the main application and •This downwash of the cool night air continues throughout the Note: Once the override button is pushed, the Belimo motor is be used and put to better purposes. benefit of natural ventilation is during the summer months. night, purging the building of any stale air, leaving the quite slow in operation and it takes approximately two minutes Nevertheless, we do recognise that in mid-season (spring and for the dampers to fully operate. The end user should, • Many of the older air conditioning systems are relatively building feeling fresh and clean the following day. autumn) natural ventilation is also desirable and, of course, in therefore, be instructed not to keep pushing the button! noisy and create their own headaches and noise problems. winter months, trickle ventilation is recommended. We also •A sensor will close the dampers automatically should the recognise that there can be ‘freak’ temperature conditions, If the Project is fitted with air quality sensors, the air quality • Air conditioning systems must be properly and regularly internal temperature drop to below 15°C. The controls reset where natural ventilation is required and it is for these reasons, sensors will always override the temperature sensors and will maintained; they eventually wear out and must be replaced. themselves for normal operation from 6am onwards. we have considered that a range of options should be provided. drive the dampers fully open if the air quality deteriorates.