Aprilaire Automatic Whole-House Humidifiers.Pdf What You Should Look for in a Humidifier Automatic Whole-Home Humidifiers Aprilaire Humidifier Specifications Sq

Total Page:16

File Type:pdf, Size:1020Kb

Aprilaire Automatic Whole-House Humidifiers.Pdf What You Should Look for in a Humidifier Automatic Whole-Home Humidifiers Aprilaire Humidifier Specifications Sq Minnesota Heating & Air Conditioning - Aprilaire Automatic Whole-House Humidifiers.pdf What you should look for in a humidifier Automatic Whole-Home Humidifiers Aprilaire Humidifier Specifications Sq. Ft. Area A. Unit Size (inches) Water Electrical Data (air changes/hr.) B. Plenum Opening (inches) Evap Rate Feed Rate Model 700*/700M** 1,050 loose house (2) A. 15-29/32W x 18H x 10-11/32D 0.75 gph 6 gph 120V-60Hz Powered Unit – 2,100 avg. house (1) B. 14-3/4W x 14-5/16H 0.8 AMP Built-in fan that pulls 4,200 tight house (1/2) heated air directly from the furnace. Model 600*/600M** 1,000 loose house (2) A. 15-3/8W x 15-3/4H x 10-1/4D 0.70 gph 3 gph 24V-60Hz CONTINUOUS AUTOMATIC CONTROL – 24/7 Bypass Unit – Uses 2,000 avg. house (1) 6” dia. round opening 0.5 AMP 1 the furnace blower to 4,000 tight house (1/2) B. 10W x 12-3/4H The optimum levels of relative humidity in your home move air through a Cure indoor dryness Water Panel.® fluctuate with the changes in outdoor temperature. An Model 400*/400M** 1,000 loose house (2) A. 15-3/8W x 15-3/4H x 10-1/4D 0.70 gph N/A 24V-60Hz Aprilaire automatic humidifier continually monitors and Bypass Unit – Uses 2,000 avg. house (1) 6” dia. round opening 0.5 AMP 100% of water and 4,000 tight house (1/2) B. 10W x 12-3/4H and get the very best responds to both outdoor temperatures and indoor evaporative ^NOTE: Heat pumps – Model 400 can be installed in heat pump applications. However, due to the fact that heat pumps deliver lower temperature air to relative humidity, delivering optimum levels of humidity technology that the home than gas furnaces, evaporation will be approximately 60 % of rated capacity. (With other Aprilaire models hot water can be used instead of cold eliminates the need to maximize evaporation. However, due to the nature of the wicking water panel in the Model 400 hot water provides no extra benefit.) As such, your throughout your home. You never have to monitor your dealer will need to take the size and age of your home into consideration to ensure the Model 400 will provide satisfactory comfort and protection through for a drain. adequate humidification. whole-home comfort. settings or wait until you feel uncomfortable. The Model 500*/500M** 750 loose house (2) A. 15-5/8W x 13H x 10-1/4D 0.50 gph 3 gph 24V-60Hz Economy Unit – 1,500 avg. house (1) 6” dia. round opening 0.5 AMP automatic set-it-and-forget-it control keeps your home’s Designed for smaller 3,000 tight house (1/2) B. 9-1/2W x 9-1/2H humidity level exactly where you want it. homes. 1,100 loose house (2) A. 13-3/4W x 12-3/4H x 12-1/2D** 0.50 gph 6 gph 120V-60Hz Model 350/360 Self-contained 2,250 avg. house (1) Note: Model 350 is 15D 0.7 AMP Humidifiers – Designed 4,500 tight house (1/2) B. N/A Note: Model 350 is to bring all the benefits 0.9 AMP of Aprilaire humidification to homes with radiators 2 WHOLE-HOME CAPACITY or baseboard heat. Model 350/360 An installed whole-home humidifier adds Self-contained * = Automatic Digital Control (shown) the right amount of soothing moisture to Humidifiers **M = Manual Control For those rare occurrences where an automatic control is not practical, Aprilaire digital control can be installed in manual mode, while still delivering the your entire home. To achieve the same accuracy and information you need for optimum performance. effect with a portable unit, you would need Warranty – All Aprilaire models are warranted for five (5) years from date of installation for parts. Heat Pumps – Plumbing the humidifier to hot water is recommended on all heat pump installations or if it is installed to operate independently of a call for heat. (See ^NOTE for Model 400) to place one in every room of your house. Bypass humidifiers can be installed on the supply or return plenum. APRILAIRE WHOLE-HOME PORTABLE UNITS HUMIDIFIER Aprilaire offers a full line of comfort accessories that improve indoor air quality throughout your home. For over 60 years, we’ve developed best-in-class innovations 3 MINIMAL MAINTENANCE, TOTAL CONVENIENCE for the ultimate in quality, performance, reliability and sustainability, including: To maintain the performance of a portable unit, you must continually monitor the tank levels and clean and fill them regularly. TM A whole-home system is installed out of your living space as part of your heating system, providing quiet operation without Humidifiers, Dehumidifiers, Air Cleaners, Zoned Comfort Control , Thermostats and Ventilation. the messy tank. And, Aprilaire’s Automatic Digital Control provides all of the information necessary for easy maintenance. There’s no need to experience the discomfort, health problems or damage to your home and furnishings caused by air that is too dry. Install an Aprilaire whole-home humidifier with Automatic Digital Control and you’ll never worry about proper humidity levels in your home again. The bottom line.... whole home + automatic digital control = peace of mind. Form No. 186 5.09 Printed in USA P.O. Box 1467 Madison, WI 53701-1467 www.aprilaire.com © 2009 Research Products Corporation www.aprilaire.com 800-334-6011 • fax: 608-257-4357 Minnesota Heating & Air Conditioning - Aprilaire Automatic Whole-House Humidifiers.pdf Every home needs a humidifier. Trust your comfort—and your home—to Aprilaire. Get information no other humidifier delivers Digital control provides more accuracy Professionally Installed…Designed and Engineered for Unsurpassed Performance. and information—exclusively from Aprilaire Humidified Air (Vapor) The air inside your home is drier than you think. Aprilaire Humidifiers provide Automatically delivers proper amounts of humidity regardless of temperature or conditions – 24/7 Duct humidity in the form of pure water Water Supply Heating your home dries out the air. The resulting dry air absorbs moisture from vapor to prevent minerals from Water DIGITAL CONTROL PANEL entering the air stream. Distribution Tray you and everything inside your home. Even newer, tighter built homes will DELIVERS PEACE OF MIND Water is supplied to the distribution succumb to the negative effects of air that is too dry. Get all of the information you tray and flows evenly across the need at a glance. Water Panel®. Heat from the heating Trust Aprilaire, the industry leader in whole-home Drain system causes the water to evaporate. Know your humidifiers. Since 1954, millions of Aprilaire humidifiers Properly humidified air (vapor) is Water relative humidity. ® have been installed to maintain comfortable, healthy then distributed throughout your Panel Backlit display provides the Forced Air Heat homes during the long, cold days of winter. entire home. Dry Air current humidity level in your home. Install an Aprilaire whole-home humidifier today Know when your system is running. IRRITATION AND UNHEALTHY AIR: HOME DAMAGE: HIGHER ENERGY COSTS: —enjoy unparalleled comfort tonight! The green light clearly shows that Know when to DISCOMFORT: Viruses thrive in low humidity When heated air isn’t Dry air robs the moisture PROVIDE TOTAL comfort Preserve YOUR HOME AND FURNISHINGS your humidifier is up, running and replace the water panel. Know immediately when conditions and can actually properly humidified, it from your skin, making you service is needed. When you heat your Proper humidity eliminates the irritations and annoyances of Your home and its furnishings make up what is likely your largest protecting your home, comfort The “smart” feature measures causes walls and ceilings feel colder, which means The red light indicates that service home, indoor humidity increase the likelihood of excessively dry air. Aprilaire whole-home humidifiers provide investment. By providing constant humidity control, Aprilaire and health. usage of your water panel, and is needed, while the digital display levels fall below the getting colds, flu and other to crack and wood floors you turn up the heat. Dry maximum comfort throughout your entire home—every hour, humidifiers help to keep them in good condition, maintaining lets you know when it’s time provides the service code that your optimum range. This upper respiratory ailments. and trim to separate. air also shrinks the framing every day, all season long, without the mess and inconvenience for replacement. their value and extending their life. contractor can use to isolate the causes you to experience The American Society of Expensive musical around doors and windows, of portables. cause, saving time and money. the discomforts of too dry Otolaryngology advises instruments can go out resulting in gaps that let in SAVE MONEY ON energy BILLS itchy skin, annoying static the importance of preventing of tune and electronic cold air from the outside, HELP PROTECT YOUR FAMILY’S health An Aprilaire whole-home humidifier allows you to feel warmer shocks and being “too cold” an overly dry environment equipment can fall victim making your home less Proper humidity is key to staying healthy in winter. By at lower thermostat settings. The U.S. Environmental Protection at normal temperatures. because it significantly to static electric charges, energy efficient. Get green keeping your sinuses and airways moist, you reduce the Agency reports that you can save up to 4% on your heating bill increases susceptibility requiring expensive repair with greater comfort potential for bacteria and viruses to enter your body. Aprilaire for every degree you lower your thermostat. to infection. or replacement. humidifiers are proven most effective at providing optimum from Aprilaire levels of humidity.
Recommended publications
  • Wind- Chimney
    WIND-CHIMNEY Integrating the Principles of a Wind-Catcher and a Solar-Chimney to Provide Natural Ventilation A Thesis presented to the Faculty of California Polytechnic State University, San Luis Obispo In Partial Fulfillment of the Requirements for the Degree Master of Science in Architecture by Fereshteh Tavakolinia December 2011 WIND-CHIMNEY Integrating the Principles of a Wind-Catcher and a Solar-Chimney to Provide Natural Ventilation © 2011 Fereshteh Tavakolinia ALL RIGHTS RESERVED ii COMMITTEE MEMBERSHIP TITLE: WIND-CHIMNEY Integrating the Principles of a Wind-Catcher and a Solar-Chimney to Provide Natural Ventilation AUTHOR: Fereshteh Tavakolinia DATE SUBMITTED: December 2011 COMMITTEE CHAIR: James A. Doerfler, Associate Department Head COMMITTEE MEMBER: Jacob Feldman, Professor iii WIND-CHIMNEY Integrating the principles of a wind-catcher and a solar chimney to provide natural ventilation Fereshteh Tavakolinia Abstract This paper suggests using a wind-catcher integrated with a solar-chimney in a single story building so that the resident might benefit from natural ventilation, a passive cooling system, and heating strategies; it would also help to decrease energy use, CO2 emissions, and pollution. This system is able to remove undesirable interior heat pollution from a building and provide thermal comfort for the occupant. The present study introduces the use of a solar-chimney with an underground air channel combined with a wind-catcher, all as part of one device. Both the wind-catcher and solar chimney concepts used for improving a room’s natural ventilation are individually and analytically studied. This paper shows that the solar-chimney can be completely used to control and improve the underground cooling system during the day without any electricity.
    [Show full text]
  • Solar Heating and Cooling & Solar Air-Conditioning Position Paper
    Task 53 New Generation Solar Cooling & Heating Systems (PV or solar thermally driven systems) Solar Heating and Cooling & Solar Air-Conditioning Position Paper November 2018 Contents Executive Summary ............................................................. 3 Introduction and Relevance ................................................ 4 Status of the Technology/Industry ...................................... 5 Technical maturity and basic successful rules for design .............. 7 Energy performance for PV and Solar thermally driven systems ... 8 Economic viability and environmental benefits .............................. 9 Market status .................................................................................... 9 Potential ............................................................................. 10 Technical potential ......................................................................... 10 Costs and economics ..................................................................... 11 Market opportunities ...................................................................... 12 Current Barriers ................................................................. 12 Actions Needed .................................................................. 13 This document was prepared by Daniel Neyer1,2 and Daniel Mugnier3 with support by Alexander Thür2, Roberto Fedrizzi4 and Pedro G. Vicente Quiles5. 1 daniel neyer brainworks, Oberradin 50, 6700 Bludenz, Austria 2 University of Innsbruck, Technikerstr. 13, 6020 Innsbruck, Austria
    [Show full text]
  • Air Conditioning and Refrigeration Systems
    AAS (60 SCH*) ® Air Conditioning *Semester Credit Hour 8/2020 First Semester - 15 SCH Second Semester - 15 SCH COSC 1301 - Introduction to Computing HART 1341 - Residential Air Conditioning HART 1301 - Basic Electricity for HVAC HART 1345 - Gas and Electric Heating HART 1307 - Refrigeration Principles HART 2341 - Commercial Air Conditioning HART 1310 - HVAC Shop Practices and Tools HART 2349 - Heat Pumps PSYC 1300 - Learning Framework SPCH 1321 - Business & Professional Communication Third Semester - 15 SCH Fourth Semester - 15 SCH HART 2331 - Advanced Electricity for HVAC HART 2334 - Advanced Air Conditioning Controls HART 2336 - Air Conditioning Troubleshooting HART 2343 - Industrial Air Conditioning HART 2338 - Air Conditioning Installation & Startup HART 1356 - EPA Recovery Certification Preparation HART 2345 - Residential Air Conditioning Systems Design MATH 1332 - Contemporary Mathematics ENGL 1301 - Composition I DRAM 1310 - Introduction to Theater Marketable Skills Program Outcomes Math Skills; manage time and materials; acquire and evaluate • Install, troubleshoot and repair refrigerators, freezers, and information; interpret and communicate information; oral and window air conditioners. written communications skills; computer skills; teamwork; cultural • Install, troubleshoot and repair split or package residential diversity; apply technology to work; creative thinking; decision air conditioning systems, including electric furnaces, gas making; problem solving; self-management; construction and furnaces and heat pumps. industrial
    [Show full text]
  • Wind Catchers
    Journal of Sustainable Development Vol. 3, No. 2; June 2010 Wind Catchers: Remarkable Example of Iranian Sustainable Architecture Amirkhani Aryan (Corresponding author's address) Department of Architecture, Faculty of Art, University of Tarbiat Modares, Jalal Ale Ahmad St, Tehran, Iran Tel/Fax: 98-21-4441-6537 E-mail: [email protected] Zamani Ehsan Department of Architecture, Faculty of Art, University of Tarbiat Modares, Jalal Ale Ahmad St, Tehran, Iran Tel/Fax: 98-21-4427-2493 E-mail: [email protected] Saidian Amin Department of Architecture, Faculty of Art, University of shahid beheshti, velenjak St, Tehran, Iran Tel/Fax: 98-21-6601-9587 E-mail: [email protected] Khademi Masoud Department of Urban design, Faculty of Art, University of Tarbiat Modares, Jalal Ale Ahmad St, Tehran, Iran Abstract As scientists we tend to view technology as a scientific system but in fact the success of a particular technology at a particular time may rest less on its efficient performance and more on its 'social' relevance and impact. We now need to identify sustainable design investments for a very uncertain future of expanding populations, scarcer resources and climate change. Buildings in the Iranian desert regions are constructed according to the specific climatic conditions and differ with those built in other climates. Desert buildings are equipped with air traps, arched roofed, water reservoirs with arched domes and ice stores for the preservation of ice. The operation of modern coolers is similar to the old Iranian air traps which were built at the entrance of the house over underground water reservoirs or ponds built inside the house.
    [Show full text]
  • Indoor Air Quality in Commercial and Institutional Buildings
    Indoor Air Quality in Commercial and Institutional Buildings OSHA 3430-04 2011 Occupational Safety and Health Act of 1970 “To assure safe and healthful working conditions for working men and women; by authorizing enforcement of the standards developed under the Act; by assisting and encouraging the States in their efforts to assure safe and healthful working conditions; by providing for research, information, education, and training in the field of occupational safety and health.” This publication provides a general overview of a particular standards-related topic. This publication does not alter or determine compliance responsibili- ties which are set forth in OSHA standards, and the Occupational Safety and Health Act of 1970. More- over, because interpretations and enforcement poli- cy may change over time, for additional guidance on OSHA compliance requirements, the reader should consult current administrative interpretations and decisions by the Occupational Safety and Health Review Commission and the courts. Material contained in this publication is in the public domain and may be reproduced, fully or partially, without permission. Source credit is requested but not required. This information will be made available to sensory- impaired individuals upon request. Voice phone: (202) 693-1999; teletypewriter (TTY) number: 1-877- 889-5627. Indoor Air Quality in Commercial and Institutional Buildings Occupational Safety and Health Administration U.S. Department of Labor OSHA 3430-04 2011 The guidance is advisory in nature and informational in content. It is not a standard or regulation, and it neither creates new legal obligations nor alters existing obligations created by OSHA standards or the Occupational Safety and Health Act.
    [Show full text]
  • Solar Cooling Used for Solar Air Conditioning - a Clean Solution for a Big Problem
    Solar Cooling Used for Solar Air Conditioning - A Clean Solution for a Big Problem Stefan Bader Editor Werner Lang Aurora McClain csd Center for Sustainable Development II-Strategies Technology 2 2.10 Solar Cooling for Solar Air Conditioning Solar Cooling Used for Solar Air Conditioning - A Clean Solution for a Big Problem Stefan Bader Based on a presentation by Dr. Jan Cremers Figure 1: Vacuum Tube Collectors Introduction taics convert the heat produced by solar energy into electrical power. This power can be “The global mission, these days, is an used to run a variety of devices which for extensive reduction in the consumption of example produce heat for domestic hot water, fossil energy without any loss in comfort or lighting or indoor temperature control. living standards. An important method to achieve this is the intelligent use of current and Photovoltaics produce electricity, which can be future solar technologies. With this in mind, we used to power other devices, such as are developing and optimizing systems for compression chillers for cooling buildings. architecture and industry to meet the high While using the heat of the sun to cool individual demands.” Philosophy of SolarNext buildings seems counter intuitive, a closer look AG, Germany.1 into solar cooling systems reveals that it might be an efficient way to use the energy received When sustainability is discussed, one of the from the sun. On the one hand, during the time first techniques mentioned is the use of solar that heat is needed the most - during the energy. There are many ways to utilize the winter months - there is a lack of solar energy.
    [Show full text]
  • Air Conditioning and Refrigeration Chronology
    Air Conditioning and Refrigeration C H R O N O L O G Y Significant dates pertaining to Air Conditioning and Refrigeration revised May 4, 2006 Assembled by Bernard Nagengast for American Society of Heating, Refrigerating and Air Conditioning Engineers Additions by Gerald Groff, Dr.-Ing. Wolf Eberhard Kraus and International Institute of Refrigeration End of 3rd. Century B.C. Philon of Byzantium invented an apparatus for measuring temperature. 1550 Doctor, Blas Villafranca, mentioned process for cooling wine and water by adding potassium nitrate About 1597 Galileo’s ‘air thermoscope’ Beginning of 17th Century Francis Bacon gave several formulae for refrigeration mixtures 1624 The word thermometer first appears in literature in a book by J. Leurechon, La Recreation Mathematique 1631 Rey proposed a liquid thermometer (water) Mid 17th Century Alcohol thermometers were known in Florence 1657 The Accademia del Cimento, in Florence, used refrigerant mixtures in scientific research, as did Robert Boyle, in 1662 1662 Robert Boyle established the law linking pressure and volume of a gas a a constant temperature; this was verified experimentally by Mariotte in 1676 1665 Detailed publication by Robert Boyle with many fundamentals on the production of low temperatures. 1685 Philippe Lahire obtained ice in a phial by enveloping it in ammonium nitrate 1697 G.E. Stahl introduced the notion of “phlogiston.” This was replaced by Lavoisier, by the “calorie.” 1702 Guillaume Amontons improved the air thermometer; foresaw the existence of an absolute zero of temperature 1715 Gabriel Daniel Fahrenheit developed mercury thermoneter 1730 Reamur introduced his scale on an alcohol thermometer 1742 Anders Celsius developed Centigrade Temperature Scale, later renamed Celsius Temperature Scale 1748 G.
    [Show full text]
  • Operating and Maintenance Manual Slope Or Flat Top Console Unit
    Operating and Maintenance Manual CHPW Slope or Flat Top Console Unit Water Source Heat Pump (WSHP) Unit Contents Welcome Welcome........................................................ 2 Congratulations on your selection of the ICE AIR Water Source Heat Consumer Safety Information/Guidelines ... 3 Pump (WSHP). The WSHP is a combination cooling and heating Components and Parts View ........................ 4 unit that provides an efficient room by room source for comfort Nomenclature ............................................... 5 conditioning of your living environment. Controls ......................................................... 6 ICE AIR WSHP Console units are built to a high standard of quality LCD Programmable Operation..................7-9 and reliability, employing commercial grade components and heavy Maintenance ..........................................10-11 duty, galvanized sheet metal casings. With proper maintenance and Troubleshooting .......................................... 12 usage, ICE AIR WSHPs should provide many years of efficient, quiet Warranty/Contact Information ................... 16 and trouble-free comfort. To enhance the use of your ICE AIR equipment, you will want to read and carefully follow all of the instructions contained in this Operating and Maintenance Manual. We recommend that you pay special attention to the Safety and Warning Information section at the beginning of this Manual, and to the various safety advisories throughout this Manual. Please retain this Manual for your future reference. We suggest that you keep it with other important documents and product manuals. If your unit has optional features, they will be explained in a separate instruction sheet specific to that option. On behalf of ICE AIR, and our network of distributors and dealers, we are happy to welcome you to our base of satisfied customers! We recommend that you record the following information about your ICE AIR product(s).
    [Show full text]
  • Solutions for Air Humidification and Evaporative Cooling
    Solutions for air humidication and evaporative cooling Control Solutions and Humidification Systems for HVAC/R high efficiency solutions Can protecting the environment be reconciled with our industrialised society? Yes, today this is possible. Indeed, this is the concept of sustainable development: improving the quality of the life, without overloading the supporting ecosystems that it depends on, now made possible by progresses in technology. While until recently sustainable development was simply a desire, a cost and an obligation defined by legislators so as to bequeath a healthy planet to future generations, today it is the only plausible choice. Changing public awareness continues to focus on the more worthy companies, rewarding these with higher sales. A need has thus become an opportunity, a chance not to be missed to unite the need to develop products and services that save energy with the possibility to effectively reduce environmental impact. To encourage sustainable development, many activities are underway as concerns both the environmental policies of individual nations and international organisations (above all the European Union), and specific research and development work. Today, then, solutions to combat global warming and pollution, to live a sustainable existence, to make our cities more liveable and our factories more efficient and virtuous all exist: the technology is here. control energy respect for the consumption environment CAREL has always developed and promoted evolved control systems, proposing innovative solutions in the HVAC/R sector. These are our “high efficiency solutions”, a clear response for environmental protection through optimised and integrated control systems, capable of bringing significant energy savings and consequently reducing environmental impact.
    [Show full text]
  • Air Conditioning Fans One of the Equipment Series
    Air Conditioning Clinic Air Conditioning Fans One of the Equipment Series February 2012 TRG-TRC013-EN Air Conditioning Fans One of the Equipment Series A publication of Trane Preface Air Conditioning Fans A Trane Air Conditioning Clinic Figure 1 Trane believes that it is incumbent on manufacturers to serve the industry by regularly disseminating information gathered through laboratory research, testing programs, and field experience. The Trane Air Conditioning Clinic series is one means of knowledge sharing. It is intended to acquaint a nontechnical audience with various fundamental aspects of heating, ventilating, and air conditioning. We’ve taken special care to make the clinic as uncommercial and straightforward as possible. Illustrations of Trane products only appear in cases where they help convey the message contained in the accompanying text. This particular clinic introduces the concept of air conditioning fans. © 2004 Trane. All rights reserved ii TRG-TRC013-EN Contents Introduction ........................................................... 1 period one Fan Performance .................................................. 2 Fan Performance Curves ....................................... 11 System Resistance Curve ...................................... 17 Fan – System Interaction ....................................... 19 period two Fan Types .............................................................. 27 Forward Curved (FC) Fans ..................................... 28 Backward Inclined (BI) Fans ..................................
    [Show full text]
  • The Future of Air Conditioning for Buildings
    The Future of Air Conditioning for Buildings July 2016 W. Goetzler, M. Guernsey, J. Young, J. Fuhrman Navigant Consulting, Inc. O. Abdelaziz, PhD Oak Ridge National Laboratory (This page intentionally left blank) NOTICE This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government, nor any agency thereof, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency, contractor or subcontractor thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. Available electronically at www.osti.gov/home/ Prepared for: U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Building Technologies Office eere.energy.gov/buildings Prepared by: Navigant Consulting, Inc. 77 South Bedford Street, Suite 400 Burlington, MA 01803 William Goetzler Matt Guernsey Jim Young Jay Fuhrman Oak Ridge National Laboratory
    [Show full text]
  • Improving Ventilation and Indoor Air Quality During Wildfire Smoke Events Recommendations for Schools and Buildings with Mechanical Ventilation
    Improving Ventilation and Indoor Air Quality during Wildfire Smoke Events Recommendations for Schools and Buildings with Mechanical Ventilation Overview • Smoke is a complex mixture of carbon dioxide (CO2), water vapor, carbon monoxide (CO), hydrocarbons, other organic chemicals, nitrogen oxides (NOX), trace minerals, and particulate matter. o Particulate matter consists of solid particles and liquid droplets suspended in the air. Particles with diameters less than 10 microns (PM10) are upper respiratory tract and eye irritants. o Smaller particles (PM2.5) are the greatest health concern – they can be inhaled deep into the lungs, and can affect respiratory and heart health. o Carbon monoxide, a colorless, odorless gas produced by incomplete combustion, is a particular health concern and levels are highest during the smoldering stages of a fire. • Outdoor (ambient) air pollutants, including smoke, enter and leave buildings in three primary ways: 1. Mechanical ventilation systems, which actively draw in outdoor air through intake vents and distribute it throughout the building. 2. Natural ventilation (opening of doors or windows). 3. Infiltration, the passive entry of unfiltered outdoor air through small cracks and gaps in the building shell. • Tightly closed buildings reduce exposure to outdoor air pollution. Upgrading the filter efficiency of the heating, ventilating, and air-conditioning (HVAC) system and changing filters frequently during smoke events greatly improves indoor air quality. Supplementing with HEPA filters, particularly those with activated charcoal or other adsorbents, improves air quality even more. • During long-term smoke events, take advantage of periods of improved air quality (such as during rain or shifts in wind) to use natural ventilation to flush-out the building.
    [Show full text]