SPD-RAID4: Splitting Parity Disk for RAID4 Structured Parallel SSD Arrays
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
VIA RAID Configurations
VIA RAID configurations The motherboard includes a high performance IDE RAID controller integrated in the VIA VT8237R southbridge chipset. It supports RAID 0, RAID 1 and JBOD with two independent Serial ATA channels. RAID 0 (called Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup. RAID 1 (called Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive. JBOD (Spanning) stands for Just a Bunch of Disks and refers to hard disk drives that are not yet configured as a RAID set. This configuration stores the same data redundantly on multiple disks that appear as a single disk on the operating system. Spanning does not deliver any advantage over using separate disks independently and does not provide fault tolerance or other RAID performance benefits. If you use either Windows® XP or Windows® 2000 operating system (OS), copy first the RAID driver from the support CD to a floppy disk before creating RAID configurations. -
D:\Documents and Settings\Steph
P45D3 Platinum Series MS-7513 (v1.X) Mainboard G52-75131X1 i Copyright Notice The material in this document is the intellectual property of MICRO-STAR INTERNATIONAL. We take every care in the preparation of this document, but no guarantee is given as to the correctness of its contents. Our products are under continual improvement and we reserve the right to make changes without notice. Trademarks All trademarks are the properties of their respective owners. NVIDIA, the NVIDIA logo, DualNet, and nForce are registered trademarks or trade- marks of NVIDIA Corporation in the United States and/or other countries. AMD, Athlon™, Athlon™ XP, Thoroughbred™, and Duron™ are registered trade- marks of AMD Corporation. Intel® and Pentium® are registered trademarks of Intel Corporation. PS/2 and OS®/2 are registered trademarks of International Business Machines Corporation. Windows® 95/98/2000/NT/XP/Vista are registered trademarks of Microsoft Corporation. Netware® is a registered trademark of Novell, Inc. Award® is a registered trademark of Phoenix Technologies Ltd. AMI® is a registered trademark of American Megatrends Inc. Revision History Revision Revision History Date V1.0 First release for PCB 1.X March 2008 (P45D3 Platinum) Technical Support If a problem arises with your system and no solution can be obtained from the user’s manual, please contact your place of purchase or local distributor. Alternatively, please try the following help resources for further guidance. Visit the MSI website for FAQ, technical guide, BIOS updates, driver updates, and other information: http://global.msi.com.tw/index.php? func=faqIndex Contact our technical staff at: http://support.msi.com.tw/ ii Safety Instructions 1. -
Designing Disk Arrays for High Data Reliability
Designing Disk Arrays for High Data Reliability Garth A. Gibson School of Computer Science Carnegie Mellon University 5000 Forbes Ave., Pittsbugh PA 15213 David A. Patterson Computer Science Division Electrical Engineering and Computer Sciences University of California at Berkeley Berkeley, CA 94720 hhhhhhhhhhhhhhhhhhhhhhhhhhhhh This research was funded by NSF grant MIP-8715235, NASA/DARPA grant NAG 2-591, a Computer Measurement Group fellowship, and an IBM predoctoral fellowship. 1 Proposed running head: Designing Disk Arrays for High Data Reliability Please forward communication to: Garth A. Gibson School of Computer Science Carnegie Mellon University 5000 Forbes Ave. Pittsburgh PA 15213-3890 412-268-5890 FAX 412-681-5739 [email protected] ABSTRACT Redundancy based on a parity encoding has been proposed for insuring that disk arrays provide highly reliable data. Parity-based redundancy will tolerate many independent and dependent disk failures (shared support hardware) without on-line spare disks and many more such failures with on-line spare disks. This paper explores the design of reliable, redundant disk arrays. In the context of a 70 disk strawman array, it presents and applies analytic and simulation models for the time until data is lost. It shows how to balance requirements for high data reliability against the overhead cost of redundant data, on-line spares, and on-site repair personnel in terms of an array's architecture, its component reliabilities, and its repair policies. 2 Recent advances in computing speeds can be matched by the I/O performance afforded by parallelism in striped disk arrays [12, 13, 24]. Arrays of small disks further utilize advances in the technology of the magnetic recording industry to provide cost-effective I/O systems based on disk striping [19]. -
Disk Array Data Organizations and RAID
Guest Lecture for 15-440 Disk Array Data Organizations and RAID October 2010, Greg Ganger © 1 Plan for today Why have multiple disks? Storage capacity, performance capacity, reliability Load distribution problem and approaches disk striping Fault tolerance replication parity-based protection “RAID” and the Disk Array Matrix Rebuild October 2010, Greg Ganger © 2 Why multi-disk systems? A single storage device may not provide enough storage capacity, performance capacity, reliability So, what is the simplest arrangement? October 2010, Greg Ganger © 3 Just a bunch of disks (JBOD) A0 B0 C0 D0 A1 B1 C1 D1 A2 B2 C2 D2 A3 B3 C3 D3 Yes, it’s a goofy name industry really does sell “JBOD enclosures” October 2010, Greg Ganger © 4 Disk Subsystem Load Balancing I/O requests are almost never evenly distributed Some data is requested more than other data Depends on the apps, usage, time, … October 2010, Greg Ganger © 5 Disk Subsystem Load Balancing I/O requests are almost never evenly distributed Some data is requested more than other data Depends on the apps, usage, time, … What is the right data-to-disk assignment policy? Common approach: Fixed data placement Your data is on disk X, period! For good reasons too: you bought it or you’re paying more … Fancy: Dynamic data placement If some of your files are accessed a lot, the admin (or even system) may separate the “hot” files across multiple disks In this scenario, entire files systems (or even files) are manually moved by the system admin to specific disks October 2010, Greg -
Identify Storage Technologies and Understand RAID
LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals IdentifyIdentify StorageStorage TechnologiesTechnologies andand UnderstandUnderstand RAIDRAID LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Lesson Overview In this lesson, you will learn: Local storage options Network storage options Redundant Array of Independent Disk (RAID) options LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Anticipatory Set List three different RAID configurations. Which of these three bus types has the fastest transfer speed? o Parallel ATA (PATA) o Serial ATA (SATA) o USB 2.0 LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Local Storage Options Local storage options can range from a simple single disk to a Redundant Array of Independent Disks (RAID). Local storage options can be broken down into bus types: o Serial Advanced Technology Attachment (SATA) o Integrated Drive Electronics (IDE, now called Parallel ATA or PATA) o Small Computer System Interface (SCSI) o Serial Attached SCSI (SAS) LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Local Storage Options SATA drives have taken the place of the tradition PATA drives. SATA have several advantages over PATA: o Reduced cable bulk and cost o Faster and more efficient data transfer o Hot-swapping technology LESSON 4.1_4.2 98-365 Windows Server Administration Fundamentals Local Storage Options (continued) SAS drives have taken the place of the traditional SCSI and Ultra SCSI drives in server class machines. SAS have several -
6 O--C/?__I RAID-II: Design and Implementation Of
f r : NASA-CR-192911 I I /N --6 o--c/?__i _ /f( RAID-II: Design and Implementation of a/t 't Large Scale Disk Array Controller R.H. Katz, P.M. Chen, A.L. Drapeau, E.K. Lee, K. Lutz, E.L. Miller, S. Seshan, D.A. Patterson r u i (NASA-CR-192911) RAID-Z: DESIGN N93-25233 AND IMPLEMENTATION OF A LARGE SCALE u DISK ARRAY CONTROLLER (California i Univ.) 18 p Unclas J II ! G3160 0158657 ! I i I \ i O"-_ Y'O J i!i111 ,= -, • • ,°. °.° o.o I I Report No. UCB/CSD-92-705 "-----! I October 1992 _,'_-_,_ i i I , " Computer Science Division (EECS) University of California, Berkeley Berkeley, California 94720 RAID-II: Design and Implementation of a Large Scale Disk Array Controller 1 R. H. Katz P. M. Chen, A. L Drapeau, E. K. Lee, K. Lutz, E. L Miller, S. Seshan, D. A. Patterson Computer Science Division Electrical Engineering and Computer Science Department University of California, Berkeley Berkeley, CA 94720 Abstract: We describe the implementation of a large scale disk array controller and subsystem incorporating over 100 high performance 3.5" disk chives. It is designed to provide 40 MB/s sustained performance and 40 GB capacity in three 19" racks. The array controller forms an integral part of a file server that attaches to a Gb/s local area network. The controller implements a high bandwidth interconnect between an interleaved memory, an XOR calculation engine, the network interface (HIPPI), and the disk interfaces (SCSI). The system is now functionally operational, and we are tuning its performance. -
Data Storage and High-Speed Streaming
FYS3240 PC-based instrumentation and microcontrollers Data storage and high-speed streaming Spring 2013 – Lecture #8 Bekkeng, 8.1.2013 Data streaming • Data written to or read from a hard drive at a sustained rate is often referred to as streaming • Trends in data storage – Ever-increasing amounts of data – Record “everything” and play it back later – Hard drives: faster, bigger, and cheaper – Solid state drives – RAID hardware – PCI Express • PCI Express provides higher, dedicated bandwidth Overview • Hard drive performance and alternatives • File types • RAID • DAQ software design for high-speed acquisition and storage Streaming Data with the PCI Express Bus • A PCI Express device receives dedicated bandwidth (250 MB/s or more). • Data is transferred from onboard device memory (typically less than 512 MB), across a dedicated PCI Express link, across the I/O bus, and into system memory (RAM; 3 GB or more possible). It can then be transferred from system memory, across the I/O bus, onto hard drives (TB´s of data). The CPU/DMA-controller is responsible for managing this process. • Peer-to-peer data streaming is also possible between two PCI Express devices. PXI: Streaming to/from Hard Disk Drives RAM – Random Access Memory • SRAM – Static RAM: Each bit stored in a flip-flop • DRAM – Dynamic RAM: Each bit stored in a capacitor (transistor). Has to be refreshed (e.g. each 15 ms) – EDO DRAM – Extended Data Out DRAM. Data available while next bit is being set up – Dual-Ported DRAM (VRAM – Video RAM). Two locations can be accessed at the same time – SDRAM – Synchronous DRAM. -
RAID Technology
RAID Technology Reference and Sources: y The most part of text in this guide has been taken from copyrighted document of Adaptec, Inc. on site (www.adaptec.com) y Perceptive Solutions, Inc. RAID stands for Redundant Array of Inexpensive (or sometimes "Independent") Disks. RAID is a method of combining several hard disk drives into one logical unit (two or more disks grouped together to appear as a single device to the host system). RAID technology was developed to address the fault-tolerance and performance limitations of conventional disk storage. It can offer fault tolerance and higher throughput levels than a single hard drive or group of independent hard drives. While arrays were once considered complex and relatively specialized storage solutions, today they are easy to use and essential for a broad spectrum of client/server applications. Redundant Arrays of Inexpensive Disks (RAID) "KILLS - BUGS - DEAD!" -- TV commercial for RAID bug spray There are many applications, particularly in a business environment, where there are needs beyond what can be fulfilled by a single hard disk, regardless of its size, performance or quality level. Many businesses can't afford to have their systems go down for even an hour in the event of a disk failure; they need large storage subsystems with capacities in the terabytes; and they want to be able to insulate themselves from hardware failures to any extent possible. Some people working with multimedia files need fast data transfer exceeding what current drives can deliver, without spending a fortune on specialty drives. These situations require that the traditional "one hard disk per system" model be set aside and a new system employed. -
Techsmart Representatives
Wave TechSmart representatives RAID BASICS ARE YOUR SECURITY SOLUTIONS FAULT TOLERANT? Redundant Array of Independent Disks (RAID) is a Enclosure: The "box" which contains the controller, storage technology used to improve the processing drives/drive trays and bays, power supplies, and fans is capability of storage systems. This technology is called an "enclosure." The enclosure includes various designed to provide reliability in disk array systems and controls, ports, and other features used to connect the to take advantage of the performance gains offered by RAID to a host for example. an array of mulple disks over single-disk storage. Wave RepresentaCves has experience with both high- RAID’s two primary underlying concepts are (1) that performance compuCng and enterprise storage, providing distribuCng data over mulple hard drives improves soluCons to large financial instuCons to research performance and (2) that using mulple drives properly laboratories. The security industry adopted superior allows for any one drive to fail without loss of data and compuCng and storage technologies aGer the transiCon without system downCme. In the event of a disk from analog systems to IP based networks. This failure, disk access will conCnue normally and the failure evoluCon has created robust and resilient systems that will be transparent to the host system. can handle high bandwidth from video surveillance soluCons to availability for access control and emergency Originally designed and implemented for SCSI drives, communicaCons. RAID principles have been applied to SATA and SAS drives in many video systems. Redundancy of any system, especially of components that have a lower tolerance in MTBF makes sense. -
Memory Systems : Cache, DRAM, Disk
CHAPTER 24 Storage Subsystems Up to this point, the discussions in Part III of this with how multiple drives within a subsystem can be book have been on the disk drive as an individual organized together, cooperatively, for better reliabil- storage device and how it is directly connected to a ity and performance. This is discussed in Sections host system. This direct attach storage (DAS) para- 24.1–24.3. A second aspect deals with how a storage digm dates back to the early days of mainframe subsystem is connected to its clients and accessed. computing, when disk drives were located close to Some form of networking is usually involved. This is the CPU and cabled directly to the computer system discussed in Sections 24.4–24.6. A storage subsystem via some control circuits. This simple model of disk can be designed to have any organization and use any drive usage and confi guration remained unchanged of the connection methods discussed in this chapter. through the introduction of, fi rst, the mini computers Organization details are usually made transparent to and then the personal computers. Indeed, even today user applications by the storage subsystem presenting the majority of disk drives shipped in the industry are one or more virtual disk images, which logically look targeted for systems having such a confi guration. like disk drives to the users. This is easy to do because However, this simplistic view of the relationship logically a disk is no more than a drive ID and a logical between the disk drive and the host system does not address space associated with it. -
6Gb/S SATA RAID TB User Manual
6Gb/s SATA RAID TB T12-S6.TB - Desktop RM12-S6.TB - Rackmount User Manual Version: 1.0 Issue Date: October, 2013 ARCHTTP PROXY SERVER INSTALLATION 5.5 For Mac OS 10.X The ArcHttp proxy server is provided on the software CD delivered with 6Gb/s SATA RAID controller or download from the www.areca. com.tw. The firmware embedded McRAID storage manager can configure and monitor the 6Gb/s SATA RAID controller via ArcHttp proxy server. The Archttp proxy server for Mac pro, please refer to Chapter 4.6 "Driver Installation" for Mac 10.X. 5.6 ArcHttp Configuration The ArcHttp proxy server will automatically assign one additional port for setup its configuration. If you want to change the "archttp- srv.conf" setting up of ArcHttp proxy server configuration, for example: General Configuration, Mail Configuration, and SNMP Configuration, please start Web Browser http:\\localhost: Cfg As- sistant. Such as http:\\localhost: 81. The port number for first con- troller McRAID storage manager is ArcHttp proxy server configura- tion port number plus 1. • General Configuration: Binding IP: Restrict ArcHttp proxy server to bind only single interface (If more than one physical network in the server). HTTP Port#: Value 1~65535. Display HTTP Connection Information To Console: Select “Yes" to show Http send bytes and receive bytes information in the console. Scanning PCI Device: Select “Yes” for ARC-1XXX series controller. Scanning RS-232 Device: No. Scanning Inband Device: No. 111 ARCHTTP PROXY SERVER INSTALLATION • Mail (alert by Mail) Configuration: To enable the controller to send the email function, you need to configure the SMTP function on the ArcHttp software. -
University of California Santa Cruz Incorporating Solid
UNIVERSITY OF CALIFORNIA SANTA CRUZ INCORPORATING SOLID STATE DRIVES INTO DISTRIBUTED STORAGE SYSTEMS A dissertation submitted in partial satisfaction of the requirements for the degree of DOCTOR OF PHILOSOPHY in COMPUTER SCIENCE by Rosie Wacha December 2012 The Dissertation of Rosie Wacha is approved: Professor Scott A. Brandt, Chair Professor Carlos Maltzahn Professor Charlie McDowell Tyrus Miller Vice Provost and Dean of Graduate Studies Copyright c by Rosie Wacha 2012 Table of Contents Table of Contents iii List of Figures viii List of Tables xii Abstract xiii Acknowledgements xv 1 Introduction 1 2 Background and Related Work 6 2.1 Data Layouts for Redundancy and Performance . 6 RAID . 8 Parity striping . 10 Parity declustering . 12 Reconstruction performance improvements . 14 iii Disk arrays with higher fault tolerance . 14 2.2 Very Large Storage Arrays . 17 Data placement . 17 Ensuring reliability of data . 19 2.3 Self-Configuring Disk Arrays . 20 HP AutoRAID . 21 Sparing . 22 2.4 Solid-State Drives (SSDs) . 24 2.5 Mitigating RAID’s Small Write Problem . 27 2.6 Low Power Storage Systems . 29 2.7 Real Systems . 31 3 RAID4S: Supercharging RAID Small Writes with SSD 32 3.1 Improving RAID Small Write Performance . 32 3.2 Related Work . 38 All-SSD RAID arrays . 39 Hybrid SSD-HDD RAID arrays . 40 Other solid state technology . 41 3.3 Small Write Performance . 41 3.4 The RAID4S System . 43 3.5 The Low Cost of RAID4S . 46 3.6 Reduced Power Consumption . 48 iv 3.7 RAID4S Simulation Results . 52 Simulated array performance . 56 3.8 Experimental Methodology & Results .