Infortrend RAID Controller Manual
Total Page:16
File Type:pdf, Size:1020Kb
Infortrend External RAID Controller Generic Operation Manual Revision 1.4 Firmware Revision: 3.21 Infortrend Infortrend Corporation Infortrend Technology, Inc. 131 Stony Circle, Suite 300 Technology, Ltd. 8F, No. 102, Chung-Shan Santa Rosa, CA 95401 Beijing Office Rd., Sec. 3 USA Room 1236-1237, Tower C; Chung-Ho City, Taipei Hsien Corporate Square Taiwan www.infortrend.com No. 35 Financial Street, ftp.infortrend.com Xicheng District, www.infortrend.com.tw Beijing, China 100032 ftp.infortrend.com.tw www.infortrend.com.cn Copyright © 2001 This Edition First Published 2001 All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written consent of Infortrend Technology, Inc. Disclaimer Infortrend Technology makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Infortrend Technology reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation to notify any person of such revisions or changes. Product specifications are also subject to change without notice. Trademarks Infortrend and the Infortrend logo are registered trademarks and IFT-3101, IFT-3102, IFT-3102U2, IFT-3101U2G, IFT-3102U2G, SentinelRAID, EonRAID, RAIDWatch, and other names prefixed with IFT are trademarks of Infortrend Technology, Inc. PowerPC is a registered trademark of International Business Machines Corporation and Motorola Inc. DEC and Alpha are registered trademarks of Compaq Computer Corp. (formerly of Digital Equipment Corporation). Microsoft, Windows, Windows NT and MS-DOS are registered trademarks of Microsoft Corporation in the U.S. and other countries. Novell and NetWare are registered trademarks of Novell, Inc. in the U.S. and other countries. SCO, OpenServer, and UnixWare are trademarks or registered trademarks of The Santa Cruz Operation, Inc. in the U.S. and other countries. Solaris is a trademark of SUN Microsystems, Inc. ii UNIX is a registered trademark of The Open Group in the U.S. and other countries. All other names, brands, products or services are trademarks or registered trademarks of their respective companies. RMA Policy Please visit our websites (www.infortrend.com/www.infortrend.com.tw/ww.infortrend.com.cn/w ww.infortrend-europe.com) where our RMA policy is given a detailed explanation. Printed in Taiwan iii Table of Contents About This Manual......................................................................................xiii Functional Table of Contents ...................................................................xv Chapter 1 Introduction Chapter 2 Functional Description 2.1 Logical Drive .......................................................................................2-1 2.2 Logical Volume ...................................................................................2-1 2.3 RAID Levels ........................................................................................2-2 NRAID................................................................................................2-3 JBOD .................................................................................................2-3 RAID 0 ...............................................................................................2-3 RAID 1 ...............................................................................................2-4 RAID (0+1)..........................................................................................2-4 RAID 3 ...............................................................................................2-5 RAID 5 ...............................................................................................2-5 2.4 Spare Drives .......................................................................................2-6 2.4.1 Global and Local Spare Drive ................................................................2-6 2.4.2 Identifying Drives .................................................................................2-7 Flash Selected SCSI Drive ...................................................................2-7 Flash All SCSI Drives...........................................................................2-8 Flash All but Selected Drives ................................................................2-8 2.4.3 Automatic Rebuild and Manual Rebuild..................................................2-9 Automatic Rebuild ...............................................................................2-9 Manual Rebuild ................................................................................. 2-10 2.4.4 Concurrent Rebuild in RAID (0+1)........................................................ 2-10 2.5 Logical Volume (Multi-Level RAID)....................................................... 2-11 Limitations:....................................................................................... 2-13 Partitioning ....................................................................................... 2-14 Multi-level RAID systems ................................................................... 2-15 Chapter 3 RAID Planning 3.1 Considerations ....................................................................................3-1 3.2 Configuring the Array: ..........................................................................3-3 3.2.1 Starting a RAID System.......................................................................3-3 3.3 Operation Theory .................................................................................3-4 3.3.1 I/O Channel, SCSI ID, and LUN.............................................................3-4 3.3.2 Understanding Step by Step.................................................................3-5 3.3.3 Preparing the Array..............................................................................3-7 Chapter 4 Out-of-Band via Serial Port and Ethernet 4.1 By RS-232..........................................................................................4-1 4.1.1 Configuring RS-232 Connection via Front Panel ......................................4-1 4.1.2 Starting RS-232 Terminal Emulation......................................................4-3 4.2 Out-of-Band via Ethernet ......................................................................4-4 4.2.1 Requirements......................................................................................4-4 4.2.2 Configuration Procedure .......................................................................4-4 iv Chapter 5 LCD Screen Messages 5.1 The Initial Screen.................................................................................5-1 5.2 Quick Installation Screen......................................................................5-1 5.3 Logical Drive Status .............................................................................5-2 5.4 Logical Volume Status .........................................................................5-3 5.5 SCSI Drive Status ................................................................................5-4 5.6 SCSI Channel Status ...........................................................................5-5 5.7 Controller Voltage and Temperature.......................................................5-6 5.8 Cache Dirty Percentage .......................................................................5-7 5.9 View and Edit Event Logs .....................................................................5-7 Chapter 6 Front Panel Operation 6.1 Power on RAID Enclosure....................................................................6-1 6.2 Caching Parameters ............................................................................6-1 6.3 View Connected Drives: .......................................................................6-4 6.4 Creating a Logical Drive .......................................................................6-6 6.5 Creating a Logical Volume ...................................................................6-8 6.6 Partitioning a Logical Drive/Logical Volume............................................6-9 6.7 Mapping a Logical Volume/Logical Drive to Host LUN ...........................6-10 6.8 Assigning Spare Drive and Rebuild Settings.........................................6-11 6.9 Viewing and Editing Logical Drives and Drive Members .........................6-13 6.10 Viewing and Editing Host LUNs ..........................................................6-17 6.11 Viewing and Editing SCSI Drives.........................................................6-18 6.12 Viewing and Editing SCSI Channels....................................................6-20 6.13 System Functions .............................................................................6-27 6.14 Controller Parameters ........................................................................6-30 6.15 SCSI Drive Utilities.............................................................................6-31 Chapter 7 Terminal Screen Messages 7.1 The Initial Screen.................................................................................7-1 7.2 Main Menu..........................................................................................7-2 7.3 Quick Installation.................................................................................7-2