Keysight Infiniivision 3000 X-Series Oscilloscopes User's Guide Infiniivision 3000 X-Series Oscilloscopes—At a Glance
Total Page:16
File Type:pdf, Size:1020Kb
Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide Notices © Keysight Technologies, Inc. 2005-2013 Warranty ment users will receive no greater than Lim- ited Rights as defined in FAR 52.227-14 No part of this manual may be reproduced in The material contained in this docu- any form or by any means (including elec- (June 1987) or DFAR 252.227-7015 (b)(2) ment is provided “as is,” and is subject (November 1995), as applicable in any tech- tronic storage and retrieval or translation into to being changed, without notice, in nical data. a foreign language) without prior agreement future editions. Further, to the maxi- and written consent from Keysight Technolo- mum extent permitted by applicable Safety Notices gies, Inc. as governed by United States and law, Keysight disclaims all warranties, international copyright laws. either express or implied, with regard to this manual and any information con- Manual Part Number tained herein, including but not limited CAUTION 75019-97073 to the implied warranties of merchant- ability and fitness for a particular pur- A CAUTION notice denotes a hazard. Edition pose. Keysight shall not be liable for It calls attention to an operating errors or for incidental or consequential procedure, practice, or the like that, Eighth edition, April 2013 damages in connection with the fur- if not correctly performed or Printed in Malaysia nishing, use, or performance of this document or of any information con- adhered to, could result in damage Published by: tained herein. Should Keysight and the to the product or loss of important Keysight Technologies, Inc. user have a separate written agreement data. Do not proceed beyond a 1900 Garden of the Gods Road with warranty terms covering the mate- Colorado Springs, CO 80907 USA rial in this document that conflict with CAUTION notice until the indicated these terms, the warranty terms in the conditions are fully understood and separate agreement shall control. met. Print History 75019-97000, January 2011 Technology Licenses 75019-97013, February 2011 The hardware and/or software described in this document are furnished under a license WARNING 75019-97014, June 2011 and may be used or copied only in accor- 75019-97027, October 2011 dance with the terms of such license. A WARNING notice denotes a haz- ard. It calls attention to an operat- 75019-97040, February 2012 Restricted Rights Legend 75019-97051, March 2012 ing procedure, practice, or the like If software is for use in the performance of a that, if not correctly performed or 75019-97062, July 2012 U.S. Government prime contract or subcon- adhered to, could result in personal 75019-97073, April 2013 tract, Software is delivered and licensed as injury or death. Do not proceed “Commercial computer software” as defined Trademarks in DFAR 252.227-7014 (June 1995), or as a beyond a WARNING notice until the “commercial item” as defined in FAR 2.101(a) indicated conditions are fully Java is a U.S. trademark of Sun Microsys- or as “Restricted computer software” as understood and met. tems, Inc. defined in FAR 52.227-19 (June 1987) or any Sun, Sun Microsystems, and the Sun Logo equivalent agency regulation or contract are trademarks or registered trademarks of clause. Use, duplication or disclosure of Sun Microsystems, Inc. in the U.S. and other Software is subject to Keysight Technologies’ countries. standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Govern- 2 Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide InfiniiVision 3000 X-Series Oscilloscopes—At a Glance Table 1 3000 X-Series Model Numbers, Bandwidths, Sample Rates Band wid th 100 MHz 200 MHz 350 MHz 500 MHz 1GHz Sample Rate (interleaved, 4 GSa/s, 4GSa/s, 4GSa/s, 4GSa/s, 5 GSa/s, non-interleaved) 2 GSa/s 2GSa/s 2GSa/s 2GSa/s 2.5 GSa/s 2-Channel + 16 Logic MSO-X 3012A MSO-X 3032A MSO-X 3052A MSO-X 3102A Channels MSO 4-Channel + 16 Logic MSO-X 3014A MSO-X 3024A MSO-X 3034A MSO-X 3054A MSO-X 3104A Channels MSO 2-Channel DSO DSO-X 3012A DSO-X 3032A DSO-X 3052A DSO-X 3102A 4-Channel DSO DSO-X 3014A DSO-X 3024A DSO-X 3034A DSO-X 3054A DSO-X 3104A The Keysight InfiniiVision 3000 X-Series oscilloscopes deliver these features: • 100 MHz, 200 MHz, 350 MHz, 500 MHz, and 1 GHz bandwidth models. • 2- and 4-channel digital storage oscilloscope (DSO) models. Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide 3 • 2+16-channel and 4+16-channel mixed-signal oscilloscope (MSO) models. An MSO lets you debug your mixed-signal designs using analog signals and tightly correlated digital signals simultaneously. The 16 digital channels have a 1 GSa/s sample rate (1.25 GSa/s for the 1 GHz models), with a 50 MHz toggle rate. • 8.5 inch WVGA display. • Interleaved 2 Mpts or non-interleaved 1 Mpts MegaZoom IV memory for the fastest waveform update rates, uncompromised. Upgradeable to 4Mpts/2Mpts. • All knobs are pushable for making quick selections. • Trigger types: edge, edge then edge, pulse width, pattern, OR, rise/fall time, Nth edge burst, runt, setup & hold, video, and USB. • Serial decode/trigger options for: CAN/LIN, FlexRay, I2C/SPI, I2S, UART/RS232, and MIL-STD-1553/ARINC 429. Lister for serial decode • Math waveforms: add, subtract, multiply, FFT, d/dt, integrate, and square root. With the DSOX3ADVMATH option, you get these additional math waveforms: Ax+B, square, absolute value, common logarithm, natural logarithm, exponential, base 10 exponential, low pass filter, high pass filter, magnify, measurement trend, chart logic bus timing, and chart logic bus state. • Reference waveform locations (2) for comparing with other channel or math waveforms. • Many built-in measurements and a measurement statistics display. • Built-in license-enabled waveform generator with: arbitrary, sine, square, ramp, pulse, DC, noise, sine cardinal, exponential rise, exponential fall, cardiac, and gaussian pulse. • USB ports make printing, saving and sharing data easy. • Optional LAN/VGA module for connecting to a network and displaying the screen on a different monitor. • Optional GPIB module. • A Quick Help system is built into the oscilloscope. Press and hold any key to display Quick Help. Complete instructions for using the quick help system are given in “Access the Built-In Quick Help" on page 44. For more information about InfiniiVision oscilloscopes, see: "www.keysight.com/find/scope" 4 Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide In This Guide This guide shows how to use the InfiniiVision 3000 X-Series oscilloscopes. When unpacking and using the • Chapter 1, “Getting Started,” starting on page 23 oscilloscope for the first time, see: When displaying waveforms and • Chapter 2, “Horizontal Controls,” starting on page 47 acquired data, see: • Chapter 3, “Vertical Controls,” starting on page 61 • Chapter 4, “Math Waveforms,” starting on page 71 • Chapter 5, “Reference Waveforms,” starting on page 99 • Chapter 6, “Digital Channels,” starting on page 103 • Chapter 7, “Serial Decode,” starting on page 121 • Chapter 8, “Display Settings,” starting on page 127 • Chapter 9, “Labels,” starting on page 133 When setting up triggers or changing • Chapter 10, “Triggers,” starting on page 139 how data is acquired, see: • Chapter 11, “Trigger Mode/Coupling,” starting on page 173 • Chapter 12, “Acquisition Control,” starting on page 181 Making measurements and analyzing • Chapter 13, “Cursors,” starting on page 199 data: • Chapter 14, “Measurements,” starting on page 209 • Chapter 15, “Mask Testing,” starting on page 237 • Chapter 16, “Digital Voltmeter,” starting on page 249 When using the built-in license • Chapter 17, “Waveform Generator,” starting on page enabled waveform generator, see: 253 When saving, recalling, or printing, • Chapter 18, “Save/Recall (Setups, Screens, Data),” see: starting on page 269 • Chapter 19, “Print (Screens),” starting on page 281 When using the oscilloscope's utility • Chapter 20, “Utility Settings,” starting on page 287 functions or web interface, see: • Chapter 21, “Web Interface,” starting on page 307 Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide 5 For reference information, see: • Chapter 22, “Reference,” starting on page 323 When using licensed serial bus • Chapter 23, “CAN/LIN Triggering and Serial Decode,” triggering and decode features, see: starting on page 343 • Chapter 24, “FlexRay Triggering and Serial Decode,” starting on page 359 • Chapter 25, “I2C/SPI Triggering and Serial Decode,” starting on page 369 • Chapter 26, “I2S Triggering and Serial Decode,” starting on page 387 • Chapter 27, “MIL-STD-1553/ARINC 429 Triggering and Serial Decode,” starting on page 397 • Chapter 28, “UART/RS232 Triggering and Serial Decode,” starting on page 413 NOTE Abbreviated instructions for pressing a series of keys and softkeys Instructions for pressing a series of keys are written in an abbreviated manner. Instructions for pressing [Key1], then pressing Softkey2, then pressing Softkey3 are abbreviated as follows: Press [Key1]> Softkey2 > Softkey3. The keys may be a front panel [Key] or a Softkey. Softkeys are the six keys located directly below the oscilloscope display. 6 Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide Contents InfiniiVision 3000 X-Series Oscilloscopes—At a Glance / 3 In This Guide / 5 1Getting Started Inspect the Package Contents / 23 Install the Optional LAN/VGA or GPIB Module / 26 Tilt the Oscilloscope for Easy Viewing