AZR Transformer Specification

Total Page:16

File Type:pdf, Size:1020Kb

AZR Transformer Specification GE Prolec Transformers Inc. ISO 9001 CERTIFIED Industrial Transformers Rodolfo Reyes GE Prolec Transformers Inc. 1223 Ph. 52 (81) 8030 2000 Ext 7802 Customer Support Engineer Fairgrove Church Road Conover, NC 28613 e-mail: [email protected] Date: 8/28/2019 Rev. 0 To: Patrick Presto Quote #: 137159 Customer: STOKES ELECTRICAL SUP GE Prop#: 151-17510 I. GENERAL DESCRIPTION AND PRICE ITEM No. 1- BU: OS002330-OPT QUANTITY: 1 GENERAL DATA SECTION DATA HIGH VOLTAGE LOW VOLTAGE STANDARD COMPLIANCE Capacity: 7500KVA Rating: 66000 V 6600 V STANDARD ANSI-C57-12 Liquid: Mineral Oil II BIL: 350 KV 75KV DOE NA Temperature Rise: 55 Material: CU CU UL No Cooling Class: ONAN Coordination: No No PIP No Impedance: 11.70% Connection: Delta Wye Class 1 DIV No 2 Frequency: 60Hz Bushing Material: Porcelain Porcelain NemaTR1 No Ambient Temperature: 30/40 °C Bushing Location: On Cover Side Wall Type of Paint Standard Altitude: 3300 ft Taps: 2; 2.5 -2; 2.5 Arrangement: Reverse Location: Outdoor Operation: Step Down Unit Price $217,800 USD Lot Price $217,800USD SHIP TO Pennsylvania Lead time (after-release) 14 - 16 ACCESSORIES Liquid Level Gauge without contacts De-energized HV Tap Changer Liquid Temperature Gauge without contacts Tank Lifting Provisions Pressure Vacuum Gauge without contacts & with bleeder Combination Drain and Filtering Valve with Sampling Pressure Test Valve Stainless Steel Ground Pads on Each End One Inch Upper Fill and Filter Press Valve Detachable Radiators with Valve Pressure Relief Device without contacts Manhole Xo on Cover Gray ANSI 61 Paint, 5 MIL Thick Flexible Conduit Provision for Hydran Aluminum Nameplate APPROXIMATE VOLUME (gallons), WEIGHTS (pounds), DIMENSIONS (inches) Shipping Dimensions (in) Height = 162 Width = 143 Length = 118 Tank Weight = 52,958 Liquid = 2,245 Gal. GE Prolec Transformers Inc. ISO 9001 CERTIFIED Industrial Transformers STOKES ELECTRICAL SUPPLY RRE http://www.prolecge.com 151-17510 CSE II. GENERAL COMMENTS Secondary substation transformers are built with rectangular windings; we take exception to circular windings as they are out of our scope. Features not specifically documented in above bill of materials should not be assumed to be included. If required, please clarify with your Customer Support Engineer properly. If a Conservator Tank is requested in the quote, please considerer that we ship conservator tank relay un-assembled. If you need the installation of these items, please let us know so we can considerer a charge adder. Spare Parts and Installation: Unless specifically stated otherwise, this quotation does not include any field related labor or materials such as but not limited to delivery, storage, handling, installation, grounding, field testing, cleaning, adjusting, training/demonstration, coordination studies, startup, special tools, spare parts, etc. Transformers are tested according to ANSI Standard Test Code for Transformers C57.12.90 This opportunity was quoted based on SST Form, we are not considering any other document which may exist. Standard accessories are being provided. We are not guaranteeing the IZ provided. GENERAL COMMENTS.- ANSI C57.12.90 includes as routine test as follow: • Resistance measurements • Ratio • Polarity and phase relation • No-load losses and excitation current • Load losses and Impedance voltage • Low frequency test (Applied and Induced potential) • Lighting impulse • Efficiency at ¼, ½, ¾, and fully load. • Voltage Regulation at 1.0 and 0.8 power factor. If you require special tests consider the next adders per transformer: Temperature each stage of cooling $2,500 Full wave impulse $1,200 Audible sound $2,000 DGA Oil Sample (each individual unit) $500 Oil PCB $100 Sweep frequency (Do not apply for pad mounted units) Not performed Zero Phase sequence impedance $500 RIV $2,500 Power factor <0.5 % (Do not apply for pad mounted units) Not performed Leak Test 6 hours $200 Telephone Influence Factor (TIF) Out of our scope Corona test Out of our scope Short circuit test Not performed *For witness test or inspection Prolec GE will charge $1,850 USD per transformer. The customer agent (Maximum 3) is responsible for furnishing his own transportation, lodging and food expense. Prolec GE will provide standard submittal package (Drawings, Certified Test Reports and O&M Manuals). STOKES ELECTRICAL SUPPLY RRE http://www.prolecge.com 151-17510 CSE Prolec GE is supplying delivery. Installation & maintenance packages shall be supplied by others Prolec GE will provide its standard domestic packing/marking that is adequate to protect the material during and after handling, stacking and shipment in a container. If you require special packing, it must be separately contracted at the port of shipment. 1) At this point we take exception to any additional specs or drawings which may exist 2) We are not considering any special commercial terms and conditions. At this point, we are quoting as per our standard Terms and Conditions of sale ES104 Rev4, unless other terms have been previously negotiated. Price and lead-time may/will change if other terms are finally agreed or negotiated 3) No liquidated damages are being considered for this quotation 4) Warranty quoted is 12 months from energization or 18 months from date of shipment, whichever occurs first. As an option, for an extended warranty of 24/30 months please ADD 2% to the quoted price and then a 1% price adder per year to a maximum of 5 years 5) Lead-time: the shipments of the transformers will start 12-14 weeks after the drawings are approved as submitted (NOT after receipt of the order) by the customer. If the order quantity Is 6-8 units or more we will evaluate shipping the units at a pre-negotiated weekly volume rate of approximately 5-10 units per week, based on the project’s requirements and factory load. When possible, we will strive to ship all transformers together, however, the final schedule will be informed via our order acknowledgment. 6)Drawings for approval: allow Prolec GE 2-4 weeks from order ACCEPTANCE (NOT from receipt of the order) to provide the approval drawings package (outline and nameplate drawings only). The drawings will be e-mailed to the customer 7)Upon return of the approval drawings the customer must clearly indicate if the drawings are “Approved for manufacturing” and/or if changes or adjustments need to be done to the drawings 8) Changes or adjustments to the contract: Any change, technical or commercial, in addition to the specific change or modification requested, a fixed administrative charges will be applicable for all contract’s or purchase order changes and modifications as follows: 1) after the order has been entered and up until 7 days from the approval drawings submittal date, a fixed charge of 1% of the transformer’s units price will be applied plus the price of the modification requested, 2) For changes requested within 7 days from the approval drawings submittal date, a charge of 3% of the transformer’s units price will be applied plus the price of the modification requested. Any changes may affect the drawings and/or shipment dates previously negotiated. Any changes requested within 7 days from the approval drawings submittal date will affect such date and must be re-scheduled at the next available drawings date 9) If changes or comments to the approval drawings are done by the customer they will need to be reviewed by Prolec GE and the price and/or lead-time of the product is subject to review and they may change STOKES ELECTRICAL SUPPLY RRE http://www.prolecge.com 151-17510 CSE GE Prolec Transformers Inc. ISO 9001 CERTIFIED Industrial Transformers III. DRAWING AND SHIPMENT CYCLES Description For Record Drawings For Approval Drawings Mailing of Drawings (Weeks) 4 4 2* Customer Drawings Return (Weeks) N/A * If Buyer exceeds the drawing approval cycle time allowed, the shipment will extend at least accordingly to the extra time taken. Actual shipment and drawings cycle will depend on factory backlog at the time of the purchase order acceptance. Shipment dates are approximate and are based upon prompt receipt of all necessary information from Buyer. IV. TERMS, CONDITIONS This proposal will remain valid for a period of 30 days after submittal. The Buyer may not make any public announcement in relation to the Contract (including to any purchase orders or related contractual documents), including the fact that it exists, without the prior written approval of Seller on such terms and conditions as All items are sold FCA (Incoterms 2010) Laredo, TX, USA, with transportation allowed to the carrier delivery point listed in this quotation within the confines of the continental United States, excluding Alaska or Hawaii. Terms of payment are 100% net cash within 30 days from date of shipment for C customers. For International and LATAM customers terms of payment are 100% net cash before shipment or letter of credit at time of order. There will be a 1.5% charge per month of the total invoice price beginning 30 days after the date of the invoice, but the amount shall not be in excess of the applicable usurious rate. Terms and conditions EM104 <http://prolecge.com/wp-content/uploads/2019/02/EM104-Grid-28Oct2015.pdf> Cancelation of Order The Buyer may cancel his order only upon a written notice and upon payment to Prolec GE of reasonable and proper cancellation charges. Cancellation Charges: % of selling price 1 week after order 10 3 weeks after order 15 Before factory release 20 1 week after release 65 2 weeks after release 70 3 weeks after release 90 4 weeks after release 100 The sale of any product or service by Prolec GE is expressly conditioned upon Buyer's assent to the terms (GE PROLEC ES104 Rev.4) contained herein. Any additional or different terms proposed by Buyer are expressly objected to and will not be binding upon Prolec GE unless specifically agreed in writing by Prolec GE's authorized representative.
Recommended publications
  • The Overall Power Factor Test: In-Depth
    The Overall Power Factor Test: In-Depth © OMICRON Page 1 Copyrighted 2019 by OMICRON electronics Corp USA All rights reserved. No part of this presentation may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or any information storage or retrieval system or method, now known or hereinafter invented or adopted, without the express prior written permission of OMICRON electronics Corp USA. © OMICRON © OMICRON Page 2 Author Biography © OMICRON Page 3 Transformer Testing Support Contacts Brandon Dupuis Fabiana Cirino Logan Merrill Charles Sweetser Primary Application Engineer Application Engineer Primary Application Engineer PRIM Engineering Services Manager OMICRON electronics Corp. USA OMICRON electronics Corp. USA OMICRON electronics Corp. USA OMICRON electronics Corp. USA 60 Hickory Drive 60 Hickory Drive 3550 Willowbend Blvd. 60 Hickory Drive Waltham MA 02451 | UNITED STATES Waltham MA 02451 | USA Houston, TX 77054 | USA Waltham MA 02451 | USA T +1 800 OMICRON T +1 800 OMICRON T +1 800 OMICRON T +1 800 OMICRON T +1 781 672 6214 T +1 781 672 6230 T +1 713 212 6154 T +1 781 672 6216 M +1 617 901 6180 M +1 781 254 8168 M +1 832 454 6943 M +1 617 947 6808 [email protected] [email protected] [email protected] [email protected] www.omicronusa.com www.omicronenergy.com www.omicronenergy.com www.omicronenergy.com © OMICRON Page 4 2019 OMICRON Academy Transformer Trainings January 30th and 31st – Houston, TX https://www.omicronenergy.com/en/events/training/detail/electrical-diagnostic-
    [Show full text]
  • 132Kv Oil Impregnated Paper Bushing Transformer - Design by CAD, Analysed by FEM
    Universal Journal of Electrical and Electronic Engineering 6(5A): 86-93, 2019 http://www.hrpub.org DOI: 10.13189/ujeee.2019.061510 132kV Oil Impregnated Paper Bushing Transformer - Design by CAD, Analysed by FEM N. Abd. Rahman1,*, M. Isa1, M. N. K. H. Rohani1, H A. Hamid1, Mohd Mustafa Al Bakri Abdullah2 1Center for Electrical System Engineering Studies, Universiti Malaysia Perlis, Malaysia 2Centre of Excellence Geopolymer and Green Technology, University Malaysia Perlis, Malaysia Received September 4, 2019; Revised December 12, 2019; Accepted December 24, 2019 Copyright©2019 by authors, all rights reserved. Authors agree that this article remains permanently open access under the terms of the Creative Commons Attribution License 4.0 International License Abstract The Electric Field and Voltage Distribution value is, the higher the price of transformer is. Transformer (EFVD) are an important parameter for assessing high used to step up the value of voltage or vise versa. voltage bushing transformer performance. However, Stepping up transformer or power transformer normally used at generation station increases the value of voltage conducting laboratories experiment is dangerous, difficult before transmitting it to many places. Normally, the and expensive due to several aspects. Therefore, Finite values of voltage practices by Tenaga Nasional Berhad Element Method (FEM) software is the best option used (TNB) for their transmission are 132kV, 275kV and 500kV. as a tool for the assessment of bushing transformer's On the other hand, stepping down transformer or performance in terms of EFVD. But, before an assessment distribution transformer is used to reduce the value of of analysis could be carried out, an accurate model of voltage depending on consumer requirement.
    [Show full text]
  • Distribution Transformers–Medium and High Voltage Section 21
    Distribution Transformers–Medium and High Voltage Section 21 com . Secondary Substation – SST .....................................................21-2 Three-phase Padmounted – PADS ..........................................21-4 Single-Phase Pole-Mounted – POLES......................................21-6 Network Transformers ..............................................................21-9 Voltage Regulators VR-1 .............................................................................................................21-10 Bushing Potential Devices......................................................21-13 ElectricalPartManuals . Publications and Reference: See Section 22 for a complete list of additional product-related publications Rev. 1/08 ® 21-1 Prices and data subject www.geelectrical.com BuyLog Catalog wwwto change without notice Distribution Transformers–Medium and High Voltage Section 21 GE-PROLEC® Liquid Filled Secondary Substation Transformers-SST GE-PROLEC® Secondary Substation Transformers will meet all of your industrial applications for power distribution. These transformers have a robust construction and are designed with the capability to coordinate with a wide diversity of equipment such as switchboards, LIS, MCCs, etc. com Applications Industrial . —Oil and Gas —Chemical Industry —Paper Industry —Steel Industry —Cement Industry Commercial —Airports —Stadiums —Office Building —Waste Water General Construction Features —Stores —The liquid insulated, secondary type substation transformer Utility is designed, manufactured
    [Show full text]
  • Diagnostics of HV Bushings Through Oil Sampling and Analysis
    DIAGNOSTICS Bushings are a critical part of the transform- er, and their failures often have destructive consequences for the transformer, with a high risk of fire ABSTRACT Bushings are highly stressed parts Diagnostics of HV of power transformers and their failures can lead to a transformer breakdown. The diagnostics and predictive surveillance of bushings bushings through is essential for uninterrupted oper- ation of transformers. Diagnostic tools applied include electrical tests, oil sampling and thermography and, to a minor extent, oil analysis for oil-impregnated bush- ings. This paper gives a short review of bushing types and related appli- analysis cations, including procedures for in field inspection and oil sampling. Dissolved Gas Analysis (DGA) issues Experience with GSU transformers in bushings’ mineral oil are briefly discussed and diagnostic criteria for 1. Introduction DGA interpretation are given, com- Bushings are extremely stressed equip­ ment, subject to a strong electric field in­ paring the experience of the authors Bushings are essential accessories of tensity with great difference of electrical with the available literature and stan- powe r transformers, circuit breakers potential and close distances. dards. and other electrical equipment, making the connection between high voltage A significant percentage of all transformer KEYWORDS wind ings and inlet or outlet conductors. failures is caused by defective bushings They allow the high voltage conductor and such failures can destroy a transform­ mineral oil, SF6, bushings, transform- to pass through the tank walls, which are er. A recent survey by CIGRE [1] conclu­ er, DGA, diagnosis ground ed. ded that 30 % of all bushing faults resulted 142 TRANSFORMERS MAGAZINE | Special Edition: Bushings, 2017 Riccardo ACTIS, Riccardo MAINA, Vander TUMIATTI in transformer fire and 10 % in burst or er dissipation factors than OIP and RIP transformer tank, during outage periods, explosion.
    [Show full text]
  • Pcore® Electric Capacitance-Graded Bushings, Test Terminals and Services
    REV. - 05/2018 ® PCORE® ELECTRIC CAPACITANCE-GRADED BUSHINGS, TEST TERMINALS AND SERVICES CA02038E_PCORE CAT_2018.indd 1 12/21/18 9:56 AM ABOUT US PCORE® Electric, an affiliate of Hubbell Power Systems Inc., is North America’s only company 100% focused on the manufacturing of capacitance-graded bushings—and related components— for transformers and oil circuit breakers in the ANSI and CSA marketplace. In addition to our wide range of precision products, we offer in-factory diagnostic services and bushing repairs that enable our customers to maximize their equipment investment. Formerly the Bushing Division of Lapp Insulator Company LLC, PCORE Electric is an ISO 9001-2015 certified supplier that continues to support all bushing products and remains committed to providing the highest quality and most reliable products supported by the outstanding level of service our customers have come to expect. That’s The Power To Serve™. For more information about PCORE, visit us today at hubbellpowersystems.com. ©2019 Hubbell Incorporated | PCORE® Electric | hubbellpowersystems.com 2 CA02038E_PCORE CAT_2018.indd 2 12/21/18 9:56 AM TABLE OF CONTENTS PAGE NO. REPLACEMENT BUSHINGS OVERVIEW 4 POC BUSHINGS POC Description 5 POC 88 Series Guide 6 POC Series II Guide (115kV-230kV) 8 POC Series II Guide (345kV-500kV) 10 CSA Standard POC Bushings 12 QUICK LINK BUSHINGS 14 PRC BUSHINGS PRC Description 17 PRC 89 Series (Oil-Filled) and Oil-Free PRC Guide 18 CSA Standard PRC Bushings 20 TEST TERMINALS 22 BUSHING REPAIR 24 DB-3 BUSHING QUICK SELECTION GUIDE 26 ©2019 Hubbell Incorporated | PCORE® Electric | hubbellpowersystems.com 3 CA02038E_PCORE CAT_2018.indd 3 12/21/18 9:56 AM REPLACEMENT BUSHINGS Equipment life extension is a key consideration for utility companies.
    [Show full text]
  • Bushing Services Trench France Sas
    BUSHING SERVICES Trench France SAS THE PROVEN POWER. WHO IS TRENCH FRANCE SAS ? Our proposal – Your beneFIT Trench France is manufacturing bushings & includes transformers bushings from 24kV up instruments transformers for more than 60 to 550kV, with rated current 800A to 5000A, years. generator bushings, current transformers & Previously known under the name of Haefely, voltage transformers. since 2004, the company belongs to the Siemens With more than 250 000 bushings in service Group. around the world, and a yearly production of As the global leader in Oil Impregnated 10 000 units, Trench is a leading player in the Paper technology (OIP), the products portfolio energy market. WHY SHOULD YOU BE CONCERNED ABOUT BUSHINGS? Transformer bushings are a critical component of a transformer and often the most forgotten one. The bushing allows the electrical power to flow from the source through the transformer and connect to the distribution network and finally to the end user. Transformer failures can result in unplanned outages which effect customers, reduce revenue and create a substantial cost to repair/rebuild the substation equipment. Several investigations of transformer failures have been done in the past, e.g. by CIGRE Transformer Reliability Survey reference WG A2.37 dated April 2012. According to these investigations bushing failures caused 17% of transformer failures. 2 THE PROVEN POWER. HOW DOES A BUSHING AGE ? The Oil Impregnated Paper (OIP) active part of the bushing, gaskets and O-rings are the key components of the bushings which will have the greatest impact on its lifetime. WHAT ARE THE FACTORS INFLUENCING THE BUSHING LIFETIME ? The high voltage OIP bushings have an average lifetime of 30 years depending on service conditions.
    [Show full text]
  • HV Transformer Installation and Maintenance Oct
    9/24/2013 TRANSFORMER INSTALLATION AND MAINTENANCE IEEE Training, Houston, Texas , Oct.8-9, 2013 Overview • Review of Basic Accessories • Installation of transformer • Transformer Maintenance 1 9/24/2013 ACCESSORIES Commonly supplied accessories are: 1. Bushings (e.g. PCORE-Lapp, ABB, HSP). 2. Winding Temperature Indicator. 3. Oil Temperature Indicator. 4. Oil Level Indicator. 5. Gas detector relay (e.g. ABB Model 11 or Buchholz). 6. Silica gel breather. 7. Fans. 8. Pumps. 9. Pressure Relief Device. 10. On-line monitors (ETM, DGA, PD, etc.). In the next few slides photos of the above accessories and construction details of some accessories are shown. PCORE Lapp POC (paper-oil-capacitor) bushing 1.Gaskets - Cork-nitrile rubber gaskets are designed to provide oil-tight seals 2. High Compression Coil Springs -provide uniform, active compressive loading on gaskets. 3. Clear-View Oil Reservoir (Medium and High Voltage Bushings) 4. Magnetic Oil Gauge (Extra High Voltage Bushings) 5. Porcelain Housing - to provide the required leakage and strike distance and has ground surfaces on top and bottom ends for oil-tight gasket seals. 6. Name Plate Data - identifies the bushing by catalog number, serial number and year of manufacture with electrical ratings and factory measurement data. 7. Power Factor Test Tap (Medium Voltage Bushings) - 25 kV through 69 kV . The test tap is connected to the ground layer of the capacitor core. 8. Voltage Tap or Capacitance Tap (High and Extra High Voltage Bushings) - Bushings rated at 115 kV and above have a permanent internal ground. In addition, an insulated tap is connected to a floating capacitor layer.
    [Show full text]
  • Polychlorinated Biphenyl (PCB) Inspection Process
    PCB Inspection Manual Disclaimer The purpose of this manual is to provide inspectors with an in- depth knowledge of the Toxic Substances Control Act (TSCA) Polychlorinated Biphenyl (PCB) inspection process. The mention of trade names, commercial products, or organizations does not imply endorsement by the U.S. Government. Table of Contents Table of Contents Page Glossary of Terms ............................................................. v Foreword ................................................................... ix Chapter One PCBs: Facts 1.0 PCBs: Facts ........................................................ 1-1 1.1 Background ......................................................... 1-1 1.2 Overview of TSCA Section 6 ............................................ 1-3 1.3 Overview of TSCA Confidential Business Information ......................... 1-7 Chapter Two Pre-Inspection Activities 2.0 Pre-Inspection Activities ................................................. 2-1 2.1 Inspection Authority .................................................... 2-1 2.2 Preparation ........................................................... 2-1 2.3 Confidential Business Information Clearance ................................ 2-3 2.4 Equipment Preparation ................................................. 2-5 Chapter Three Inspection Procedures 3.0 Inspection Procedures .................................................. 3-1 3.1 Entry ................................................................ 3-1 3.2 Opening Conference ..................................................
    [Show full text]
  • Experimental Investigations on the Dissolved Gas Analysis Method (DGA) Through Simulation of Electrical and Thermal Faults in Transformer Oil
    Experimental Investigations on the Dissolved Gas Analysis Method (DGA) through Simulation of Electrical and Thermal Faults in Transformer Oil Dissertation zur Erlangung des akademischen Grades eines Doktors der Naturwissenschaften Dr. rer. nat. vorgelegt von Jackelyn Aragon´ Gomez´ geboren in Sogamoso, Kolumbien Institute fur¨ Angewandte Analytische Chemie Fakultat¨ Chemie der Universitat¨ Duisburg-Essen 2014 Approved by the examining committee on: 27thJune; 2014 Advisor: Prof. Dr. rer. nat. Oliver Schmitz Reviewer: Prof. Dr.-Ing. Holger Hirsch Chair: Prof. Dr. rer. nat. Karin Stachelscheid This research work was developed during the period from June 2005 to Octo- ber 2008 at the Institute of Power Transmission and High Voltage Technology (IEH), University of Stuttgart, under the supervision of Prof. Dr.-Ing. Stefan Tenbohlen. I declare that this dissertation represent my own work, except where due ac- knowledgement is made. ———————- Jackelyn Aragon´ Gomez´ “Reach high, for stars lie hidden in you. Dream deep, for every dream precedes the goal.” ― Rabindranath Tagore Acknowledgment I am greatly thankful of Prof. Dr. Oliver Schmitz, Head Director of the Insti- tute of the Applied Analytical Chemistry and Prof. Dr.-Ing. Holger Hirsch, Head Director of the Institute of Electrical Power Transmission at the Uni- versity of Duisburg-Essen, for their willingness to review and examine my dissertation in spite of the time constraints and giving worth to my efforts of years. I deeply appreciate their professional and constructive approach towards my research work. I would like to mention very special thanks to Prof. Dr. Mathias Ulbricht, Head Director of Institute of Technical Chemistry for his encouragement, trust and support.
    [Show full text]
  • Using the Analysis of the Gases Dissolved in Oil in Diagnosis of Transformer Bushings with Paper-Oil Insulation—A Case Study
    energies Article Using the Analysis of the Gases Dissolved in Oil in Diagnosis of Transformer Bushings with Paper-Oil Insulation—A Case Study Tomasz Piotrowski 1 , Pawel Rozga 1,* , Ryszard Kozak 2 and Zbigniew Szymanski 3 1 Institute of Electrical Power Engineering, Lodz University of Technology, Stefanowskiego 18/22, 90-924 Lodz, Poland; [email protected] 2 Zrew Transformers S.A., Rokicinska 144, 92-412 Lodz, Poland; [email protected] 3 Energopomiar-Elektryka, Swietokrzyska 2, 44-100 Gliwice, Poland; [email protected] * Correspondence: [email protected]; Tel.: +48-42-631-2676 Received: 27 November 2020; Accepted: 18 December 2020; Published: 19 December 2020 Abstract: The article describes a case study when the voltage collapse during lightning impulse tests of new power transformers was noticed and when the repeated tests finished with a positive result. The step-by-step process of reaching the conclusion on the basis of dissolved gas analysis (DGA) as a key method of the investigations was presented. The considerations on the possible source of the analysis showed that the Duval triangle method, used in the analysis of the concentration of gases dissolved in oil samples taken from bushings, more reliably and unambiguously than the ratio method recommended in the IEC 60599 Standard, indicated a phenomenon which was identified in the insulation structure of bushings analyzed. Additionally, the results from DGA were found to be consistent with an internal inspection of bushings, which showed a visible trace of discharge on the inside part of the epoxy housing, as a result of the lightning induced breakdown.
    [Show full text]
  • Analysis of Partial Discharge in OIP Bushing Models
    Analysis of Partial Discharge in OIP Bushing Models ZEESHAN AHMED Degree project in Electical Engineering Electromagnetic Engineering Stockholm, Sweden 2011 XR-EE-ETK 2011:008 Analysis of Partial Discharge in OIP Bushing Models Zeeshan Ahmed Stockholm 2011 ________________________________________________________________ Electromagnetic Engineering School of Electrical Engineering Kungliga Tekniska Högskolan XR-EE-ETK 2011:008 Abstract A high voltage bushing is a very important accessory of power transformers. Bushings are used to insulate high voltage conductors where they feed through steel tank of a power transformer. There are different sources of electric stress that may result in degradation of bushing. Partial discharges (PDs) are one of the main sources of electrical degradation. PDs occur due to defects in electrical insulations, and can lead to insulation failure. This thesis is composed of two parts. The first part deals with design of a 145 kV oil impregnated paper (OIP) bushing by using capacitive radial grading technique. In capacitive grading the foils of calculated length are placed at predetermined radial distance between the paper layers in order to distribute voltage and electric field uniformly between high voltage conductor and ground potential. A 145kV OIP bushing was designed according to dimensions of ABB GOE type bushing. After calculations, the 145 kV bushing geometry was modeled in COMSOL Multiphysics in order to analyze the voltage and electric field distribution in the bushing. In the second part of this thesis a scaled down model was designed using the capacitive radial grading technique. After designing, the scale down model was implemented in COMSOL in order to ensure that the voltage and electric field distribution should be similar to the full scale model of bushing.
    [Show full text]
  • Amran's Bushing Current Transformers Brochure
    BUSHING CURRENT TRANSFORMERS www.amranit.com Bushing CTs Applications: Medium and High voltage circuit breakers, Large Power Transformers • For Gas insulated or Oil-immerse Applications • Various construction options available – Tape insulated CTs with polyester file / Cotton tape / fiber glass tape etc. • Wide range or ratios - single or Multi Ratios available • Various secondary options – leads, terminals etc. • High accuracies possible for metering application using nanocrystalline cores • Single core or multi core designs possible • Collapsable, returnable plastic container shipping options are available • Custom solutions to suite end application BUSHING CURRENT TRANSFORMERS BUSHING CURRENT TRANSFORMERS BUSHING CURRENT TRANSFORMERS www.amranit.com www.amranit.com Core Insulation Amran Bushing Current Transformer Amran specializes in manufacturing broad range • Cores are insulated with electrical grade Amranof Bushing specializes Current in manufacturing Transformers broadfor medium range press-pan and/or polyester film to ensure ofto Bushinghigh voltage Current circuit Transformers breakers, largefor medium power that the winding is separated from the core. generatorsto high and voltage power circuit transformers breakers, applications.large power generatorsAmran and Bushing power transformers Current Transformers applications. are • Epoxy varnish is applied on the core to producedAmran withBushing the Currenthighest qualityTransformers standards are prevent moisture ingress. andproduced they are with designed the highest in-house
    [Show full text]