Clinical & Diagnostic Practices Serving Audiologists Standard for over & Custom 65 Engineered YEARS Solutions

Audiology Rooms Toll-free 1-800-563-3574 | International +1-613-543-2967 | www.audiologyrooms.com IS0 9001:2015 and ISO 14001:2015 Due to High Traffic Corridors Many Insist on Double Wall Examination Rooms...

Noise Control Never looked so good. Best-in-class Eckel Audiometric Rooms & Suites are the first choice of Audiologists.

Audiology Audiology Room floor while the exterior walls are placed on the floor of the building. Each double wall Audiology Room is provided Work Spaces with a combination in-swing and Eckel Clinical Audiometric Rooms & Suites out-swing, flush sill, magnetic seal Your Practice Reflects Your Standard of Patient Care doors. Suitable for clinical and research applications Single Wall Rooms turn rests on “air cushion” vibra- CL10/ HL10 Series tion isolator rails. Ideal for sound Ideal for industry and private clin- field measurements, brain stem au- Single Wall Suite ics. The smaller models have an diometry, hearing aid evaluation. ​Two single wall examination inlet silencer in the rear wall and rooms can be united to form an an exhaust silencer integrated in Double Wall Rooms audiology suite. The reduc- the ceiling. In the larger models, C20 / H20 Series tion characteristics correspond to both silencers are in the ceiling Features higher the attenuation of a single wall panels. All models have a clinical characteristics which are a must in room. However, the attenuation jack panel for greater versatility. areas where the ambient noise lev- of one room with regards to the The wall panels are mounted on els are excessively high. The interi- other resembles the attenuation the audiology room floor which in or wall panels are mounted on the characteristics of a double wall.

2 Eckel Noise Control Technologies Clinical Audiology Rooms & Suites

The audiology suites are equipped ner (walking) surfaces. The floor els are supplied with twelve .25” with a wide 762mm (30”) window panels are supplied with heavy (6.3mm) phone jacks, two USB as are the majority of our rooms. duty framing members and inner connections and one 1” (25mm) This offers a particular advantage surface to support consistent use diameter pass-thru. Non-standard when testing young children, so and accommodation for clients configurations are available to suit they can see their parents during requiring wheelchair accessibility. unique or specific jack require- testing. These suites are ideal Acoustic insulation is consistent ments. for applications requiring strict with that of the wall and ceiling acoustic control in both test and panels. All floors are installed CSA Approved Electrical – control environments. on isolation mounts to protect C22.2 601.1 Medical Equip- against structure borne noise ment Single Wall Control sources. Overall step up height is ​All rooms are supplied with CSA approximately 7” (175mm) from Double Wall Exam Rooms approved, pre-wired 120 volts re- outside. Many hospitals insist on this suite. cessed internal electrical, includ- The double wall examination ing internal and external facing room assures maximum patient Doors recessed grade duplex cooperation while the single Standard door clear openings are receptacles. Power is supplied via wall control room permits live 32” (810mm) W x 73 ¾” (960mm) a power cord connected to the voice speech testing without any H. The doors are designed to pro- customer’s 120 volts source or interference from outside noise. vide similar acoustic performance may be hard wired upon request. The control room has a single door as the walls and to sit flush when Country specific electric and cord and the examination room has a installed. Hardware consists of configurations are available for double door system. These audio- chrome plated hinges with a cam international customers (240v metric suites are available with rise mechanism to ensure both option also available). or without a floor in the control proper seating of the door and room. ease of closing. A 1” (25mm) door Ceiling Integrated Silencer pull handle is used, assuring ease Systems of operation and ADA compliance. Wall & Ceiling Construction Door windows from small to full The integrated silenced ventila- Wall panels are 4” (100mm) and size are available as an option. Al- tion system consists of factory fabricated of galvanized solid ternate door sizes can be accom- installed extract air fans and a steel outer surface and perfo- modated. passive intake air flow. The fans rated steel inner surface. Ceiling are quiet, low power consumption, panels include an integrated Observation Window fans. For customers wanting to silenced ventilation system and connect to their existing HVAC Observation windows are pro- 6” (150mm) thick with galvanized system optional vent collars are vided, typical nominal size 24” solid steel outer surface and available. (610mm) W x 30” (750mm) H, perforated steel inner surface. fabricated from two layers of Acoustic insulation is dependent laminated safety glass set in an Paint Finish on panels and designed to provide extruded PVC window frame. Al- Rooms supplied in a polyurethane independently tested transmis- ternate sizes are available to suit enamel low gloss paint finish in sion loss of selected panel system Eckel White, Beige, or Warm Grey. specific needs. (C or CL). Custom color matching and fabric finishes are available on request. Isolated Floor Construction Jack Panels Floor panels are available in 2”, Jack panels are installed on all 3” and 4” (50.8mm, 76.2mm, (Jack Panels continued) 101.6mm) thick fabricated from rooms and suites both single and galvanized steel outer and in- double wall. Standard jack pan-

Eckel Noise Control Technologies 3 CL/HL Series 11 - 13 Standard Audiology Rooms Specifications

CL 11 - 13 / HL 11 - 13 Cam-Lock & H Batten Economical Single Wall All rooms and suites are available in An affordable selection of audio Audiology Rooms Cam-Lock or H Batten configurations. rooms and suites are ideal for many locations. Optional Features: HVAC Collars (1 set) Single Wall Rooms (Includes Internal Utility Box For by Others ) 7” (178mm) Total Rise Isolated Floor 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb kg

4’4” x 3’5” x 7’9” 3’8” x 2’9” x 6’6” 14.00 sq ft 1102 lb CL-11 / HL-11 1321mm x 1041mm x 2362mm 1118mm x 838mm x 1981mm 1.30 sq m 500 kg

4’4” x 4’4” x 7’9” 3’8” x 3’8” x 6’6” 18.75 sq ft 1276 lb CL-11A / HL-11A 1321mm x 1321mm x 2362mm 1118mm x 1118mm x 1981mm 1.74 sq m 579 kg

5’3” x 4’4” x 7’9” 4’7” x 3’8” x 6’6” 22.73 sq ft 1451 lb CL-12 / HL-12 1600mm x 1321mm x 2362mm 1397mm x 1118mm x 1981mm 2.11 sq m 658 kg

6’2” x 4’4” x 7’9” 5’6” x 3’8” x 6’6” 26.72 sq ft 1625 lb CL-12B / HL-12B 1880mm x 1321mm x 2362mm 1676mm x 1118mm x 1981mm 2.48 sq m 737 kg

CL-13 / HL-13 6’2” x 5’3” x 7’9” 5’6” x 4’7” x 6’6” 32.38 sq ft 1836 lb 1880mm x 1600mm x 2362mm 1676mm x 1397mm x 1981mm 3.01 sq m 833 kg

Eckel’s CL Series of audiology rooms are ideal for medium noise, high traffic areas.

4 Eckel Noise Control Technologies CL/HL Series 11 - 13 Standard Audiology Rooms Specifications

Eckel’s high quality audiology Certified Plug n’ Play Standard Features rooms and suites provide Comes fully operational. outstanding acoustic perfor- All that is required is to plug it in. f 4” (100mm) Cam-Lock mance in an environment Panel System comfortable to my patients. f 4” (100mm) Flush Mount H-Batten System f 32” W x 73 3” H (813mm x 1873mm) Clear Open- ing Door f 24” (610mm) W x 762mm (30”)H Double Glazed Window f Built in Attenuated Venti- lation System f Separate Switches for In- ternal Light and with Speed Controllers f Vibration Isolators f Color : Standard Eckel White, Beige, Warm Grey (additional colors avail- able on request) f Fully Demountable f Supplied Flat Pack (easily installed onsite) f Wide Range of Models f Low profile options are available for all models f Jack Panel is complete with 12 x 1/4” Phone Jacks, 2 USB, and a 1” (25mm) pass-through f Pre-wired Plug and Play Electrics

Eckel H Batten OCTAVE BAND FREQUENCY (HZ) ROOM MODEL 125 250 500 1K 2K 4K NIC In addition to Cam-Lock Systems, available options include the NOISE REDUCTION (dB) industry leading Eckel H Batten CL SINGLE WALL 19 30 39 50 58 59 41 Panel Connection System with a C SINGLE WALL 24 32 44 53 58 61 45 unique offset panel edge design STANDARD to fully engage top and bottom C SINGLE WALL 31 44 57 63 68 67 51 trims, creating acoustically ADVANCED sealed enclosures. H SINGLE WALL 28 36 46 53 58 62 49

Eckel Noise Control Technologies 5 CL/HL Series 12A - 17 Standard Audiology Rooms Specifications

CL 12A - 17 / HL 12A - 17 Cam-Lock & H Batten Optional Features Single Wall All rooms and suites are available in HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms Cam-Lock or H Batten Internal Utility Box For Thermostat by Others ) configurations. 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door 7” (178mm) Total Rise Isolated Floor Sprinkler Access Hole Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

7’1” x 4’4” x 7’9” 6’5” x 3’8” x 6’6” 30.67 sq ft 1799 lb CL-12A / HL-12A 2159mm x 1321mm x 2362mm 1956mm x 1118mm x 1981mm 2.85 sq m 816 kg

7’1” x 6’2” x 7’9” 6’5” x 5’6” x 6’6” 43.48 sq ft 2249 lb CL-14 / HL-14 2159mm x 1880mm x 2362mm 1956mm x 1676mm x 1981mm 4.04 sq m 1020 kg

7’1” x 7’1” x 7’9” 6’5” x 6’5” x 6’6” 50.17 sq ft 2473 lb CL-14A / HL-14A 2159mm x 2159mm x 2362mm 1956mm x 1956mm x 1981mm 4.66 sq m 1122 kg

7’1” x 8’0” x 7’9” 6’5” x 7’4” x 6’6” 56.66 sq ft 2698 lb CL-15 / HL-15 2159mm x 2438mm x 2362mm 1956mm x 2235mm x 1981mm 5.26 sq m 1224 kg

8’0” x 8’0” x 7’9” 7’4” x 7’4” x 6’6” 64.00 sq ft 2939 lb CL-15A / HL-15A 2438mm x 2438mm x 2362mm 2235mm x 2235mm x 1981mm 5.95 sq m 1333 kg

8’11” x 8’0” x 7’9” 8’3” x 7’4” x 6’6” 71.73 sq ft 3182 lb CL-16 / HL-16 2718mm x 2438mm x 2362mm 2515mm x 2235mm x 1981mm 6.66 sq m 1443 kg

9’10” x 8’11” x 7’9” 9’2” x 8’3” x 6’6” 87.68 sq ft 3699 lb CL-17 / HL-17 2997mm x 2718mm x 2362mm 2794mm x 2515mm x 1981mm 8.15 sq m 1678 kg

6 Eckel Noise Control Technologies CL/HL Series 12A - 17 Standard Audiology Rooms Specifications

Standard Features Eckel’s high quality audiology rooms are specially engineered to provide f Outstanding Noise outstanding acoustic performance in Control f Isolated from Structure a very attractive package. Borne Noise f 32” W x 73 3” H (813mm x 1873mm) Clear Opening Door f 24” x 30” (609.6mm x 762mm) Glazed Glass Win- dow Set in a Polycarbonate Frame f Excellent Visibility f Universal Jack Panel f Silenced Ventilation f Lighting Fixtures f High Density Carpeting f Easy Install, Take Down, and Moving f Acoustical Rubber Seals f Universal Door System (Left Side/Right Side Hing- es) f Colour : Standard Eckel White, Beige, Warm Grey (additional colours available on request) f Versatile range of diagnostic measurement f Comfortable and Accessible f Jack Panel is complete with 12 x 1/4” Phone Jacks, 2 USB, and a 1” (25mm) pass- through f Plug and Play Electrical

OCTAVE BAND FREQUENCY (HZ) ROOM Fully Customizable MODEL 125 250 500 1K 2K 4K NIC Eckel’s team of experts supplies customized NOISE REDUCTION (dB) rooms to meet the requirements of our valued

CL SINGLE WALL 19 30 39 50 58 59 41 audiologist clientele and their customers C SINGLE WALL 24 32 44 53 58 61 45 STANDARD C SINGLE WALL 31 44 57 63 68 67 51 ADVANCED H SINGLE WALL 28 36 46 53 58 62 49

Eckel Noise Control Technologies 7 CL/HL Series 66 - 88 Standard Audiology Rooms Specifications

CL 66 - 88 / HL 66 - 88 Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door 7” (178mm) Total Rise Isolated Floor Sprinkler Access Hole Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

6’6” x 6’6” x 7’9” 5’10” x 5’10” x 6’6” 29.75 sq ft 2045 lb CL-66 / HL-66 1981mm x 1981mm x 2362mm 1778mm x 1778mm x 1981mm 2.76 sq m 928 kg

8’0” x 8’0” x 7’9” 7’4” x 7’4” x 6’6” 45.60 sq ft 2757 lb CL-88 / HL-88 2438mm x 2438mm x 2362mm 2235mm x 2235mm x 1981mm 4.24 sq m 1250 kg

Optional Upgrades 20” x 60” (508mm x 1524mm) Window in Door & 36” (914mm) Clear Opening Door

8 Eckel Noise Control Technologies CL/HL Series 11 - 13 LP Standard Audiology Rooms Specifications

CL 11 - 13 LP / HL 11 - 13 LP Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door 1 9/16 ” (14mm) Rise - Low Profile (LP) Rubber Floor Sprinkler Access Hole Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

4’4” x 3’5” x 7’3” 3’8” x 2’9” x 6’6” 14.00 sq ft 952 lb CL-11 LP / HL-11 LP 1321mm x 1041mm x 2210mm 1118mm x 838mm x 1981mm 1.30 sq m 432 kg

4’4” x 4’4” x 7’3” 3’8” x 3’8” x 6’6” 18.75 sq ft 1086 lb CL-11A LP / HL-11A LP 1321mm x 1321mm x 2210mm 1118mm x 1118mm x 1981mm 1.74 sq m 493 kg

5’3” x 4’4” x 7’3” 4’7” x 3’8” x 6’6” 22.73 sq ft 1221 lb CL-12 LP / HL-12 LP 1600mm x 1321mm x 2210mm 1397mm x 1118mm x 1981mm 2.11 sq m 554 kg

6’2” x 4’4” x 7’3” 5’6” x 3’8” x 6’6” 26.72 sq ft 1354 lb CL-12B LP / HL-12B LP 1880mm x 1321mm x 2210mm 1676mm x 1118mm x 1981mm 2.48 sq m 614 kg

CL-13 LP / HL-13 LP 6’2” x 5’3” x 7’3” 5’6” x 4’7” x 6’6” 32.38 sq ft 1508 lb 1880mm x 1600mm x 2210mm 1676mm x 1397mm x 1981mm 3.01 sq m 684 kg

Eckel’s CL LP Series of audiology rooms are ideal for medium noise, low traffic areas.

Eckel Noise Control Technologies 9 CL/HL Series 12A - 17 LP Standard Audiology Rooms Specifications

CL 12A - 17 LP / HL 12A - 17 LP Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 1 9/16 ” (14mm) Rise - Low Profile (LP) Rubber Floor Extra Duplex Outlets

Model Outside Dimensions Inside Dimensions Floor Area Weight Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg 7’1” x 4’4” x 7’3” 6’5” x 3’8” x 6’6” 30.67 sq ft 1488 lb CL-12A LP / HL-12A LP 2159mm x 1321mm x 2210mm 1956mm x 1118mm x 1981mm 2.85 sq m 675 kg 7’1” x 6’2” x 7’3” 6’5” x 5’6” x 6’6” 43.48 sq ft 1808 lb CL-14 LP / HL-14 LP 2159mm x 1880mm x 2210mm 1956mm x 1676mm x 1981mm 4.04 sq m 820 kg 7’1” x 7’1” x 7’3” 6’5” x 6’5” x 6’6” 50.17 sq ft 1967 lb CL-14A LP / HL 14A LP 2159mm x 2159mm x 2210mm 1956mm x 1956mm x 1981mm 4.66 sq m 892 kg 7’1” x 8’0” x 7’3” 6’5” x 7’4” x 6’6” 56.66 sq ft 2126 lb CL-15 LP / HL 15 LP 2159mm x 2438mm x 2210mm 1956mm x 2235mm x 1981mm 5.26 sq m 964 kg 8’0” x 8’0” x 7’3” 7’4” x 7’4” x 6’6” 64.00 sq ft 2293 lb CL-15A LP / HL-15A LP 2438mm x 2438mm x 2210mm 2235mm x 2235mm x 1981mm 5.95 sq m 1040 kg 8’11” x 8’0” x 7’3” 8’3” x 7’4” x 6’6” 71.73 sq ft 2462 lb CL-16 LP / HL-16 LP 2718mm x 2438mm x 2210mm 2515mm x 2235mm x 1981mm 6.66 sq m 1117 kg 9’10” x 8’11” x 7’3” 9’2” x 8’3” x 6’6” 87.68 sq. ft. 2815 lb CL-17 LP / HL-17 LP 2997mm x 2718mm x 2210mm 2794mm x 2515mm x 1981mm 8.15 sq. m. 1277 kg

Eckel Audiology Booths, Rooms & Suites Definitive Noise Control.

10 Eckel Noise Control Technologies CL/HL Series 66 - 88 LP Standard Audiology Rooms Specifications

CL 66 - 88 LP / HL 66 - 88 LP Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 1 9/16 ” (14mm) Rise - Low Profile (LP) Rubber Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

6’6” x 6’6” x 7’3” 5’10” x 5’10” x 6’6” 29.75 sq ft 1618 lb CL-66 LP / HL-66 LP 1981mm x 1981mm x 2210mm 1778mm x 1778mm x 1981mm 2.76 sq m 734 kg

8’0” x 8’0” x 7’3” 7‘4” x 7’4” x 6’6” 45.60 sq ft 2112 lb CL-88 LP / HL-88 LP 2438mm x 2438mm x 2210mm 2235mm x 2235mm x 1981mm 4.24 sq m 958 kg

Noise Controlled Environments for Accurate Hearing Assessment & Sound Solutions

Eckel Noise Control Technologies 11 CL/HL Series 11 - 13 LP2 Standard Audiology Rooms Specifications

CL 11 - 13 LP2/ HL 11 - 13 LP2 Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 2” (51mm) Total Rise Isolated Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb kg

4’4” x 3’5” x 7’4” 3’8” x 2’9” x 6’6” 14.00 sq ft 1102 lb CL-11 LP2 /HL-11 LP2 1321mm x 1041mm x 2235mm 1118mm x 838mm x 1981mm 1.30 sq m 500 kg

4’4” x 4’4” x 7’4” 3’8” x 3’8” x 6’6” 18.75 sq ft 1276 lb CL-11A LP2 /HL-11A LP2 1321mm x 1321mm x 2235mm 1118mm x 1118mm x 1981mm 1.74 sq m 579 kg

5’3” x 4’4” x 7’4” 4’7” x 3’8” x 6’6” 22.73 sq ft 1451 lb CL-12 LP2 /HL-12 LP2 1600mm x 1321mm x 2235mm 1397mm x 1118mm x 1981mm 2.11 sq m 658 kg

6’2” x 4’4” x 7’4” 5’6” x 3’8” x 6’6” 26.72 sq ft 1625 lb CL-12B LP2 /HL-12B LP2 1880mm x 1321mm x 2235mm 1676mm x 1118mm x 1981mm 2.48 sq m 737 kg

CL-13 LP2 /HL-13 LP2 6’2” x 5’3” x 7’4” 5’6” x 4’7” x 6’6” 32.38 sq ft 1836 lb 1880mm x 1600mm x 2235mm 1676mm x 1397mm x 1981mm 3.01 sq m 833 kg

Eckel’s CL LP2 Series of audiology rooms are ideal for medium noise, high traffic areas.

12 Eckel Noise Control Technologies CL/HL Series 12A - 17 LP2 Standard Audiology Rooms Specifications

CL 12A - 17 LP2 / HL 12A - 17 LP2 Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 2” (51mm) Total Rise Isolated Floor Extra Duplex Outlets

Model Outside Dimensions Inside Dimensions Floor Area Weight Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg 7’1” x 4’4” x 7’4” 6’5” x 3’8” x 6’6” 30.67 sq ft 1799 lb CL-12A LP2 / HL-12A LP2 2159mm x 1321mm x 2235mm 1956mm x 1118mm x 1981mm 2.85 sq m 816 kg 7’1” x 6’2” x 7’4” 6’5” x 5’6” x 6’6” 43.48 sq ft 2249 lb CL-14 LP2 / HL-14 LP2 2159mm x 1880mm x 2235mm 1956mm x 1676mm x 1981mm 4.04 sq m 1020 kg 7’1” x 7’1” x 7’4” 6’5” x 6’5” x 6’6” 50.17 sq ft 2473 lb CL-14A LP2/ HL 14A LP2 2159mm x 2159mm x 2235mm 1956mm x 1956mm x 1981mm 4.66 sq m 1122 kg 7’1” x 8’0” x 7’4” 6’5” x 7’4” x 6’6” 56.66 sq ft 2698 lb CL-15 LP2/ HL 15 LP2 2159mm x 2438mm x 2235mm 1956mm x 2235mm x 1981mm 5.26 sq m 1224 kg 8’0” x 8’0” x 7’4” 7’4” x 7’4” x 6’6” 64.00 sq ft 2939 lb CL-15A LP2/ HL-15A LP2 2438mm x 2438mm x 2235mm 2235mm x 2235mm x 1981mm 5.95 sq m 1333 kg 8’11” x 8’0” x 7’4” 8’3” x 7’4” x 6’6” 71.73 sq ft 3182 lb CL-16 LP2 / HL-16 LP2 2718mm x 2438mm x 2235mm 2515mm x 2235mm x 1981mm 6.66 sq m 1443 kg 9’10” x 8’11” x 7’4” 9’2” x 8’3” x 6’6” 87.68 sq. ft. 3699 lb CL-17 LP2 / HL-17 LP2 2997mm x 2718mm x 2235mm 2794mm x 2515mm x 1981mm 8.15 sq. m. 1678 kg

Ductwork is a frequent pathway of unwanted sound. Eckel takes measures to reduce noise transfer through ducts and conduits.

Eckel Noise Control Technologies 13 Cornered Room

Make best use of Your Clinic’s Corner Space with a CL/HL or C/H 66-88 Corner Room with: • Standard 7” (178mm) Rise Floor (as pictured) • LP: 1 9/16” (40mm)Rise Floor • LP2: Floor with 2” (51mm) Rise Floor

14 Eckel Noise Control Technologies CL/HL 66 - 88 LP2 Standard Audiology Rooms Specifications

CL 66 - 88 LP2 / HL 66 - 88 LP2 Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 2” (51mm) Total Rise Isolated Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

6’6” x 6’6” x 7’4” 5’10” x 5’10” x 6’6” 29.75 sq ft 2045 lb CL-66 LP2 / HL-66 LP2 1981mm x 1981mm x 2235mm 1778mm x 1778mm x 1981mm 2.76 sq m 928 kg

8’0” x 8’0” x 7’4” 7‘4” x 7’4” x 6’6” 45.60 sq ft 2757 lb CL-88 LP2 / HL-88 LP2 2438mm x 2438mm x 2235mm 2235mm x 2235mm x 1981mm 4.24 sq m 1251 kg

Economical CL/HL Series Eckel Rooms & Suites Sound Solutions for Your Audiology Clinic

Eckel Noise Control Technologies 15 C/H Series

Advanced Audiology Rooms & Suites Specifications

Ease of Access The flush-mounted entry door with continuous magnetic seal allows test subjects to enter and exit easily.

C/H Series The noise control standard of the Audiology Industry, Eckel’s C/H Series represents the latest state of the art technological advancements in acoustic engineering.

16 Eckel Noise Control Technologies C/H Series 11 - 13 Advanced Audiology Rooms & Suites Specifications

C 11 - 13 / H 11 - 13 Cam-Lock & H Batten Optional Features Single Wall All rooms and suites are available in HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms Cam-Lock or H Batten Internal Utility Box For Thermostat by Others ) configurations. 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 7” (178mm) Total Rise Isolated Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg 4’4” x 3’5” x 7’9” 3’8” x 2’9” x 6’6” 14.00 sq ft C-11 / H-11 1518 lb 1321mm x 1041mm x 2362mm 1118mm x 838mm x 1981mm 1.30 sq m 689 kg 4’4” x 4’4” x 7’9” 3’8” x 3’8” x 6’6” 18.75 sq ft C-11A/H-11A 1754 lb 1321mm x 1321mm x 2362mm 1118mm x 1118mm x 1981mm 1.74 sq m 796 kg 5’3” x 4’4” x 7’9” 4’7” x 3’8” x 6’6” 22.73 sq ft C-12 / H-12 1993 lb 1600mm x 1321mm x 2362mm 1397mm x 1118mm x 1981mm 2.11 sq m 904 kg 6’2” x 4’4” x 7’9” 5’6” x 3’8” x 6’6” 26.72 sq ft C-12B/H-12B 2229 lb 1880mm x 1321mm x 2362mm 1676mm x 1118mm x 1981mm 2.48 sq m 1011 kg 6’2” x 5’3” x 7’9” 5’6” x 4’7” x 6’6” 32.38 sq ft C-13/H-13 2515 lb 1880mm x 1600mm x 2362mm 1676mm x 1397mm x 1981mm 3.01 sq m 1141 kg

Visit Eckel’s ALL NEW Audiology Website www.audiologyrooms.com Designed for Audiologists & the Audiology Market.

Eckel Noise Control Technologies 17 C/H Series 12A - 17 Advanced Audiology Rooms & Suites Specifications

C 12A - 17 / H 12A - 17 Cam-Lock & H Batten Optional Features Single Wall All rooms and suites are available in HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms Cam-Lock or H Batten Internal Utility Box For Thermostat by Others ) configurations. 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 7” (178mm) Total Rise Isolated Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg 7’1” x 4’4” x 7’9” 6’5” x 3’8” x 6’6” 30.67 sq. ft. 2466 lb C-12A / H-12A 2159mm x 1321mm x 2362mm 1956mm x 1118mm x 1981mm 2.85 sq. m. 1119 kg 7’1” x 6’2” x 7’9” 6’5” x 5’6” x 6’6” 43.48 sq. ft. 3074 lb C-14 / H-14 2159mm x 1880mm x 2362mm 1956mm x 1676mm x 1981mm 4.04 sq. m. 1394 kg 7’1” x 7’1” x 7’9” 6’5” x 6’5” x 6’6” 50.17 sq. ft. 3377 lb C-14A / H-14A 2159mm x 2159mm x 2362mm 1956mm x 1956mm x 1981mm 4.66 sq. m. 1532 kg 7’1” x 8’0” x 7’9” 6’5” x 7’4” x 6’6” 56.66 sq. ft. 3680 lb C-15 / H-15 2159mm x 2438mm x 2362mm 1956mm x 2235mm x 1981mm 5.26 sq. m. 1670 kg 8’0” x 8’0” x 7’9” 7’4” x 7’4” x 6’6” 64.00 sq. ft. 4005 lb C-15A / H-15A 2438mm x 2438mm x 2362mm 2235mm x 2235mm x 1981mm 5.95 sq. m. 1817 kg 8’11” x 8’0” x 7’9” 8’3” x 7’4” x 6’6” 71.73 sq. ft. 4333 lb C-16 / H-16 2718mm x 2438mm x 2362mm 2515mm x 2235mm x 1981mm 6.66 sq. m. 1965 kg 9’10” x 8’11” x 7’9” 9’2” x 8’3” x 6’6” 87.68 sq. ft. 5030 lb C-17 / H-17 2997mm x 2718mm x 2362mm 2794mm x 2515mm x 1981mm 8.15 sq. m. 2282 kg

Eckel’s C Series of audiology rooms are ideal for high noise, high traffic areas.

18 Eckel Noise Control Technologies C/H Series 66 - 88 Advanced Audiology Rooms & Suites Specifications

C 66 - 88 / H 66 - 88 Cam-Lock & H Batten Optional Features Single Wall All rooms and suites are available in HVAC Collars (1 set) Single Wall Rooms (Includes Audiology RoomS Cam-Lock or H Batten Internal Utility Box For Thermostat by Others ) configurations. 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 7” (178mm) Total Rise Isolated Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg 6’6” x 6’6” x 7’9” 5’10” x 5’10” x 6’6” 29.75 sq ft 2791 lb C-66 / H-66 1981mm x 1981mm x 2362mm 1778mm x 1778mm x 1981mm 2.76 sq m 1266 kg 8”0” x 8’0” x 7’9” 7’4” x 7’4” x 6’6” 45.60 sq ft 3751 lb C-88 / H-88 2438mm x 2438mm x 2362mm 2235mm x 2235mm x 1981mm 4.24 sq m 1701 kg

Eckel Booths, Rooms & Suites Noise Control for Audiometric Testing & Analysis

Eckel Noise Control Technologies 19 C/H Series 11 - 13 LP Advanced Audio Rooms Specifications

C 11 - 13 LP / H 11 - 13 LP Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology RoomS or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 1 9/16 ” (14mm) Rise - Low Profile (LP) Extra Duplex Outlets Rubber Floor

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

4’4” x 3’5” x 7’3” 3’8” x 2’9” x 6’6” 14.00 sq ft 1320 lb C-11 LP / H-11 LP 1321mm x 1041mm x 2210mm 1118mm x 838mm x 1981mm 1.30 sq m 599 kg 4’4” x 4’4” x 7’3” 3’8” x 3’8” x 6’6” 18.75 sq ft 1504 lb C-11A LP / H-11A LP 1321mm x 1321mm x 2210mm 1118mm x 1118mm x 1981mm 1.74 sq m 682 kg 5’3” x 4’4” x 7’3” 4’7” x 3’8” x 6’6” 22.73 sq ft 1689 lb C-12 LP / H-12 LP 1600mm x 1321mm x 2210mm 1397mm x 1118mm x 1981mm 2.11 sq m 766 kg 6’2” x 4’4” x 7’3” 5’6” x 3’8” x 6’6” 26.72 sq ft 1873 lb C-12B LP / H-12B LP 1880mm x 1321mm x 2210mm 1676mm x 1118mm x 1981mm 2.48 sq m 850 kg 6’2” x 5’3” x 7’3” 5’6” x 4’7” x 6’6” 32.38 sq ft 2083 lb C-13 LP / H-13 LP 1880mm x 1600mm x 2210mm 1676mm x 1397mm x 1981mm 3.01 sq m 945 kg

Noise Reduction Coefficient (NRC) ratings measure materials for their sound absorptive quality. An NRC value of 0.40 is the minimum threshold of material considered to be sound absorptive.

20 Eckel Noise Control Technologies C/H Series 12A - 17 LP Advanced Audio Rooms Specifications

C 12A - 17 LP / H 12A - 17 LP Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 1 9/16 ” (14mm) Rise - Low Profile (LP) Rubber Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg 7’1” x 4’4” x 7’3” 6’5” x 3’8” x 6’6” 30.67 sq. ft. 2057 lb C-12A LP / H-12A LP 2159mm x 1321mm x 2210mm 1956mm x 1118mm x 1981mm 2.85 sq. m. 933 kg 7’1” x 6’2” x 7’3” 6’5” x 5’6” x 6’6” 43.48 sq. ft. 2493 lb C-14 LP / H-14 LP 2159mm x 1880mm x 2210mm 1956mm x 1676mm x 1981mm 4.04 sq. m. 1131 kg 7’1” x 7’1” x 7’3” 6’5” x 6’5” x 6’6” 50.17 sq. ft. 2710 lb C-14A LP / H-14A LP 2159mm x 2159mm x 2210mm 1956mm x 1956mm x 1981mm 4.66 sq. m. 1229 kg 7’1” x 8’0” x 7’3” 6’5” x 7’4” x 6’6” 56.66 sq. ft. 2928 lb C-15 LP / H-15 LP 2159mm x 2438mm x 2210mm 1956mm x 2235mm x 1981mm 5.26 sq. m. 1328 kg 8’0” x 8’0” x 7’3” 7’4” x 7’4” x 6’6” 64.00 sq. ft. 3156 lb C-15A LP / H-15A LP 2438mm x 2438mm x 2210mm 2235mm x 2235mm x 1981mm 5.95 sq. m. 1432 kg 8’11” x 8’0” x 7’3” 8’3” x 7’4” x 6’6” 71.73 sq. ft. 3386 lb C-16 LP / H-16 LP 2718mm x 2438mm x 2210mm 2515mm x 2235mm x 1981mm 6.66 sq. m. 1536 kg 9’10” x 8’11” x 7’3” 9’2” x 8’3” x 6’6” 87.68 sq. ft. 3866 lb C-17 LP / H-17 LP 2997mm x 2718mm x 2210mm 2794mm x 2515mm x 1981mm 8.15 sq. m. 1754 kg

Eckel’s C LP Series of audiology rooms are ideal for high noise, high traffic areas.

Eckel Noise Control Technologies 21 C /H Series 66 - 88 LP Advanced Audio Rooms Specifications

C 66 - 88 LP / H 66 - 88 LP Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 1 9/16 ” (14mm) Rise - Low Profile (LP) Rubber Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area 1316Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

6’6” x 6’6” x 7’3” 5’10” x 5’10” x 6’6” 29.75 sq. ft. 2229 lb C-66 LP / H-66 LP 1981mm x 1981mm x 2210mm 1778mm x 1778mm x 1981mm 2.76 sq. m. 1011 kg 8’0” x 8’0” x 7’3” 7’4” x 7’4” x 6’6” 45.60 sq. ft. 2902 lb C-88 LP / H-88 LP 2438mm x 2438mm x 2210mm 2235mm x 2235mm x 1981mm 4.24 sq. m. 1316 kg

Audiologists Rely on Eckel Booths, Rooms & Suites to Perform & Provide Ideal Environments For Accurate Audiometric Testing & Analysis

22 Eckel Noise Control Technologies C/H Series 11 - 13 (4) LP2 Advanced Audio Rooms Specifications

C 11 - 13 (4) LP2 / H 11 - 13 (4) LP2 Cam-Lock & H Batten Optional Features Single Wall - 4" Thick All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 2” (51mm) Total Rise Isolated Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

C-11 (4) LP2 4’4” x 3’5” x 7’4” 3’8” x 2’9” x 6’6” 14.00 sq ft 1320 lb H-11 (4) LP2 1321mm x 1041mm x 2235mm 1118mm x 838mm x 1981mm 1.30 sq m 599 kg C-11A (4) LP2 4’4” x 4’4” x 7’4” 3’8” x 3’8” x 6’6” 18.75 sq ft 1504 lb H-11A (4) LP2 1321mm x 1321mm x 2235mm 1118mm x 1118mm x 1981mm 1.74 sq m 682 kg C-12 (4) LP2 5’3” x 4’4” x 7’4” 4’7” x 3’8” x 6’6” 22.73 sq ft 1689 lb H-12 (4) LP2 1600mm x 1321mm x 2235mm 1397mm x 1118mm x 1981mm 2.11 sq m 766 kg C-12B (4) LP2 6’2” x 4’4” x 7’4” 5’6” x 3’8” x 6’6” 26.72 sq ft 1873 lb H-12B (4) LP2 1880mm x 1321mm x 2235mm 1676mm x 1118mm x 1981mm 2.48 sq m 850 kg C-13 (4) LP2 6’2” x 5’3” x 7’4” 5’6” x 4’7” x 6’6” 32.38 sq ft 2083 lb H-13 (4) LP2 1880mm x 1600mm x 2235mm 1676mm x 1397mm x 1981mm 3.01 sq m 945 kg

Eckel introduces a new Low Profile floor option the LP2 low profile floor featuring a 2” (51mm) Total Rise

Eckel Noise Control Technologies 23 C/H Series 12A - 17 (4) LP2 Advanced Audio Rooms Specifications

C 12A - 17 (4) LP2 / H 12A - 17 (4) LP2 Cam-Lock & H Batten Optional Features Single Wall - 4" Thick All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 2” (51mm) Total Rise Isolated Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg C-12A (4) LP2 7’1” x 4’4” x 7’4” 6’5” x 3’8” x 6’6” 30.67 sq. ft. 2057 lb H-12A (4) LP2 2159mm x 1321mm x 2235mm 1956mm x 1118mm x 1981mm 2.85 sq. m. 933 kg C-14 (4) LP2 7’1” x 6’2” x 7’4” 6’5” x 5’6” x 6’6” 43.48 sq. ft. 2493 lb H-14 (4) LP2 2159mm x 1880mm x 2235mm 1956mm x 1676mm x 1981mm 4.04 sq. m. 1131 kg C-14A (4) LP2 7’1” x 7’1” x 7’4” 6’5” x 6’5” x 6’6” 50.17 sq. ft. 2710 lb H-14A (4) LP2 2159mm x 2159mm x 2235mm 1956mm x 1956mm x 1981mm 4.66 sq. m. 1229 kg C-15 (4) LP2 7’1” x 8’0” x 7’4” 6’5” x 7’4” x 6’6” 56.66 sq. ft. 2928 lb H-15 (4) LP2 2159mm x 2438mm x 2235mm 1956mm x 2235mm x 1981mm 5.26 sq. m. 1328 kg C-15A (4) LP2 8’0” x 8’0” x 7’4” 7’4” x 7’4” x 6’6” 64.00 sq. ft. 3156 lb H-15A (4) LP2 2438mm x 2438mm x 2235mm 2235mm x 2235mm x 1981mm 5.95 sq. m. 1432 kg C-16 (4) LP2 8’11” x 8’0” x 7’4” 8’3” x 7’4” x 6’6” 71.73 sq. ft. 3386 lb H-16 (4) LP2 2718mm x 2438mm x 2235mm 2515mm x 2235mm x 1981mm 6.66 sq. m. 1536 kg C-17 (4) LP2 9’10” x 8’11” x 7’4” 9’2” x 8’3” x 6’6” 87.68 sq. ft. 3866 lb H-17 (4) LP2 2997mm x 2718mm x 2235mm 2794mm x 2515mm x 1981mm 8.15 sq. m. 1754 kg

Eckel’s C LP2 Series of audiology rooms are ideal for high noise, high traffic areas.

24 Eckel Noise Control Technologies C/H Series 66 - 88 LP2 Advanced Audiology Rooms Specifications

C 66 - 88 LP2 / H 66 - 88 LP2 Cam-Lock & H Batten Optional Feature Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms or H Batten configurations. Internal Utility Box For Thermostat by Others ) 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 2” (51mm) Total Rise Isolated Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area 1316Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

6’6” x 6’6” x 7’4” 5’10” x 5’10” x 6’6” 29.75 sq. ft. 2229 lb C-66 LP2 / H-66 LP2 1981mm x 1981mm x 2235mm 1778mm x 1778mm x 1981mm 2.76 sq. m. 1011 kg 8’0” x 8’0” x 7’4” 7’4” x 7’4” x 6’6” 45.60 sq. ft. 2902 lb C-88 LP2 / H-88 LP2 2438mm x 2438mm x 2235mm 2235mm x 2235mm x 1981mm 4.24 sq. m. 1316 kg

Trusted Audiologists Trust Eckel for Providing Noise Control Performance Reliable & Comfortable Testing Environments

Eckel Noise Control Technologies 25 C/H Series 11 - 13 (6) LP2 Advanced Audiology Rooms Specifications

C 11-13 (6) LP2 / H 11-13 (6) LP2 Cam-Lock & H Batten Optional Features Single Wall - 6" Thick All rooms and suites are available in HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms Cam-Lock or H Batten Internal Utility Box For Thermostat by Others ) configurations. 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 2” (51mm) Total Rise Isolated Floor Extra Duplex Outlets

OCTAVE BAND FREQUENCY (HZ) ROOM NEW 125 250 500 1K 2K 4K NIC 6" Thick MODEL Walls NOISE REDUCTION (dB) C/H Series 11 - 13 (6) LP2 37 51 57 66 73 82 57

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg C-11 (6) LP2 4’4” x 3’5” x 7’4” 3’4” x 2’5” x 6’6” – 28 Clear Open 14.00 sq ft 1697 lb H-11 (6) LP2 1321mm x 1041mm x 2235mm 1016mm x 736mm x 1981mm 1.30 sq m 770 kg C-11A (6) LP2 4’4” x 4’4” x 7’4” 3’4” x 2’5” x 6’6” – 28 Clear Open 18.75 sq ft 1953 lb H-11A (6) LP2 1321mm x 1321mm x 2235mm 1016mm x 736mm x 1981mm 1.74 sq m 886 kg C-12 (6) LP2 5’3” X 4’4” x 7’4” 4’3” X 3’4” x 6’6” 22.73 sq ft 2212 lb H-12 (6) LP2 1600mm x 1321mm x 2235mm 1295mm x 1016mm x 1981mm 2.11 sq m 1003 kg C-12A (6) LP2 7’1” x 4’4” x 7’4” 6’1” X 3’4” x 6’6” 30.67 sq. ft. 2724 lb H-12A (6) LP2 2159mm x 1321mm x 2235mm 1854mm x 1016mm x 1981mm 2.85 sq. m. 1236 kg C-12B (6) LP2 6’2” X 4’4” x 7’4” 5’2” X 3’4” x 6’6” 26.72 sq ft 2468 lb H-12B (6) LP2 1880mm x 1321mm x 2235mm 1575mm x 1016mm x 1981mm 2.48 sq m 1119 kg C-13 (6) LP2 6’2” X 5’3” x 7’4” 5’2” X 4’3” x 6’6” 32.38 sq ft 2773 lb H-13 (6) LP2 1880mm x 1600mm x 2235mm 1575mm x 1295mm x 1981mm 3.01 sq m 1258 kg

Discover the superior sound absorption of Eckel's new audiology rooms featuring 6" Thick Walls.

26 Eckel Noise Control Technologies C/H Series 14 - 17 (6) LP2 Advanced Audiology Rooms Specifications

C 14-17 (6) LP2 / H 14-17 (6) LP2 Cam-Lock & H Batten Optional Features Single Wall - 6" Thick All rooms and suites are available in HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms Cam-Lock or H Batten Internal Utility Box For Thermostat by Others ) configurations. 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 2” (51mm) Total Rise Isolated Floor Extra Duplex Outlets

OCTAVE BAND FREQUENCY (HZ) ROOM NEW 125 250 500 1K 2K 4K NIC 6" Thick MODEL Walls NOISE REDUCTION (dB) C/H Series 14 - 17 (6) LP2 37 51 57 66 73 82 57

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg C-14 (6) LP2 7’1” x 6’2” x 7’4” 6’1” x 5’2” x 6’6” 43.48 sq. ft. 3370 lb H-14 (6) LP2 2159mm x 1880mm x 2235mm 1854mm x 1575mm x 1981mm 4.04 sq. m. 1529 kg C-14A (6) LP2 7’1” x 7’1” x 7’4” 6’1” x 6’1” x 6’6” 50.17 sq. ft. 3691 lb H-14A (6) LP2 2159mm x 2159mm x 2235mm 1854mm x 1854mm x 1981mm 4.66 sq. m. 1674 kg C-15 (6) LP2 7’1” x 8’0” x 7’4” 6’1” x 7’ x 6’6” 56.66 sq. ft. 4012 lb H-15 (6) LP2 2159mm x 2438mm x 2235mm 1854mm x 2134mm x 1981mm 5.26 sq. m. 1820 kg C-15A (6) LP2 8’0” x 8’0” x 7’4” 7’ x 7’ x 6’6” 64.00 sq. ft. 4355 lb H-15A (6) LP2 2438mm x 2438mm x 2235mm 2134mm x 2134mm x 1981mm 5.95 sq. m. 1975 kg C-16 (6) LP2 8’11” x 8’0” x 7’4” 7’11” x 7’ x 6’6” 71.73 sq. ft. 4701 lb H-16 (6) LP2 2718mm x 2438mm x 2235mm 2413mm x 2134mm x 1981mm 6.66 sq. m. 2132 kg C-17 (6) LP2 9’10” x 8’11” x 7’4” 8’10” x 7’11” x 6’6” 87.68 sq. ft. 5434 lb H-17 (6) LP2 2997mm x 2718mm x 2235mm 2692mm x 2413mm x 1981mm 8.15 sq. m. 2465 kg

Because Bigger is Better, we've designed new audiology rooms with 6" Thick Walls for outstanding acoustic performance.

Eckel Noise Control Technologies 27 Double-Wall Room within a Room

Audiology Booths, Rooms & Suites Quality engineering, unique design and superb acoustic characteristics are the hallmarks of Eckel’s Audiology Products & Systems

28 Eckel Noise Control Technologies C/H Series 24 - 27 Advanced Audiology Rooms Specifications

C 24 - 27 / H 24 - 27 Series Cam-Lock & H Batten Optional Features Double - Wall Clinical All rooms and suites are available in HVAC Collars (1 set) Single Wall Rooms (Includes Audiology Rooms Cam-Lock or H Batten Internal Utility Box For Thermostat by Others ) configurations. 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 7” (178mm) Total Rise Isolated Floor Extra Duplex Outlets

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg 8’5” x 7’5” x 8’5” 6’5” x 5’5” x 6’6” 62.43 sq ft 3562 lb C-24 / H-24 2565mm x 2261mm x 2565mm 1956mm x 1651mm x 1981mm 5.80 sq m 1616 kg 9’4” x 8’5” x 8’5” 7’4” x 6’5” x 6’6” 78.53 sq ft 4078 lb C-25 / H-25 2845mm x 2565mm x 2565mm 2235mm x 1676mm x 1981mm 7.30 sq m 1850 kg 10’3” x 9’4” x 8’5” 8’3” x 7’4” x 6’6” 95.63 sq ft 4634 lb C-26 / H-26 3124mm x 2845mm x 2565mm 2515mm x 2235mm x 1981mm 8.88 sq m 2102 kg 11’2” x 10’3” x 8’5” 9’2” x 8’3” x 6’6” 114.4 sq ft 5189 lb C-27 / H-27 3404mm x 3124mm x 2565mm 2794mm x 2515mm x 1981mm 10.63 sq m 2354 kg

OCTAVE BAND FREQUENCY (HZ) ROOM MODEL 125 250 500 1K 2K 4K NIC NOISE REDUCTION (dB) C DOUBLE WALL 44 58 75 86 91 95 67 STANDARD H DOUBLE WALL 48 64 79 81 79 >95 70 STANDARD H DOUBLE WALL 48 67 95 >95 >95 >95 71 ADVANCED

Eckel’s Double Wall C Series of audiology rooms are ideal for high noise, high traffic areas.

Eckel Noise Control Technologies 29 ADA C/H 14 - 17 LP ADA Audiology Rooms Specifications

ADA C 14 - 17 LP / H 14 - 17 LP Cam-Lock & H Batten Optional Features: Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes ADA Compliant or H Batten configurations. Internal Utility Box For Thermostat by Others ) Audiology Rooms 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 1 9/16 ” (14mm) Rise - Low Profile (LP) Extra Duplex Outlets Rubber Floor

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg 7’1” x 6’2” x 7’9” 6’5” x 5’6” x 7’ 43.48 sq. ft. 2646 lb ADA C-14 LP / H-14 LP 2159mm x 1880mm x 2372mm 1956mm x 1676mm x 2134mm 4.04 sq. m. 1200 kg 7’1” x 7’1” x 7’9” 6’5” x 6’5” x 7’ 50.17 sq. ft. 2874 lb ADA C-14A LP / H-14A LP 2159mm x 2159mm x 2372mm 1956mm x 1956mm x 2134mm 4.66 sq. m. 1303 kg 7’1” x 8’0” x 7’9” 6’5” x 7’4” x 7’ 56.66 sq. ft. 3102 lb ADA C-15 LP / H-15 LP 2159mm x 2438mm x 2372mm 1956mm x 2235mm x 2134mm 5.26 sq. m. 1407 kg 8’0” x 8’0” x 7’9” 7’4” x 7’4” x 7’ 64.00 sq. ft. 3340 lb ADA C-15A LP / H-15A LP 2438mm x 2438mm x 2372mm 2235mm x 2235mm x 2134mm 5.95 sq. m. 1515 kg 8’11” x 8’0” x 7’9” 8’3” x 7’4” x 7’ 71.73 sq. ft. 3581 lb ADA C-16 LP / H-16 LP 2718mm x 2438mm x 2372mm 2515mm x 2235mm x 2134mm 6.66 sq. m. 1624 kg 9’10” x 8’11” x 7’9” 9’2” x 8’3” x 7’ 87.68 sq. ft. 4083 lb ADA C-17 LP / H-17 LP 2997mm x 2718mm x 2372mm 2794mm x 2515mm x 2134mm 8.15 sq. m. 1852 kg

The Americans with Disabilities Act prohibits discrimination and guarantees that people requiring accommodation have the same rights to opportunities and services as everyone else.

30 Eckel Noise Control Technologies ADA C/H 88 LP ADA Audiology Rooms Specifications

ADA C 88 LP / H 88 LP Cam-Lock & H Batten Optional Features Single Wall All rooms are available in Cam-Lock HVAC Collars (1 set) Single Wall Rooms (Includes ADA Compliant or H Batten configurations. Internal Utility Box For Thermostat by Others ) Audiology Rooms 20” BY 60” (508mm x 1524mm) Window in Door Upgrade TO 36” Clear Opening Door Sprinkler Access Hole 1 9/16 ” (14mm) Rise - Low Profile (LP) Extra Duplex Outlets Rubber Floor

Outside Dimensions Inside Dimensions Floor Area Weight Model Width (W) x Depth (D) x Height (H) Width (W) x Depth (D) x Height (H) sq ft / sq m lb / kg

8’0” x 8’0” x 7’9” 7’4” x 7’4” x 7’ 45.60 sq ft 3066 lb ADA C-88 LP / H-88 LP 2483mm x 2483mm x 2362mm 2235mm x 2235mm x 2134mm 4.24 sq m 1391 kg

Eckel ADA Compliant Booths, Rooms & Suites Provide Wheelchair Access & Accomodation for People with Disabilities.

Eckel Noise Control Technologies 31 Audiology Business

My clients deserve respect, privacy and a high level of comfort above all...

Your Practice Made Perfect Your professionalism and the environment you provide for your clients together ensure your practice is successful. Audiologists Grow Their Business By Providing Client-focused Environments I never want my you present to your valued satisfaction. patients to feel clientele or patients. A modern and well-appointed environ- Successful claustrophobic or ment creates a clear path to audiologists put uncomfortable during repeat business and to building the needs and hearing aid tests... a portfolio of satisfied clients. accommodations of their patients A number of elements come You are the reflection of first. together to determine whether your high standards and your an audiology career or busi- audiology clinic is a reflection An attractive ness is ultimately successful. of your commitment to your audiology booth, clientele. room or suite In addition to an audiologist’s from Eckel is a professionalism, proficient Eckel engineered noise control sound investment in your career. skill-set and a controlled noise products and systems create Eckel Noise Control products and environment - perhaps the custom environments condu- systems are the true standard of the most important factor to stay- cive to privacy, accommodation audiology industry. ing competitive is the setting and end-user comfort and

32 Eckel Noise Control Technologies Custom Finishes

Custom finishes help to comfort children and families

Limitless Possibility Eckel has a wide variety of customized panel, room and suite treatments to make your audiology environment a reflection of you and the clients you serve. ckel’s engineered present your audiology noise control prod- business ahead of the ucts and systems are competition. Children and strong to the finish adults alike are thrilled to with a wide variety find brilliant pictures and of custom treatments colours over the expected eto appeal to the style sterility of traditional and tastes of your valued workplace environments. clientele.

Dream it! Push the limits of your A finish of greens and white make a state of the art imagination! Eckel Design audiology system in Ireland shine. Eckel’s customized Teams deliver a variety of approach to end-user satisfaction allows our clients creative custom finishes, and their customers to enjoy a wide array of attractive corporate branding, bright color and image overlay treatments. imagery and memorable An audiologist and her hot pink color combinations to suite bring joy to a child.

Eckel Noise Control Technologies 33 Audiology Booths, Rooms & Suites

Custom Designs Custom Designed Engineered Noise Control Products and Professionalism Systems are available from AUDIOLOGY Eckel. We are up to any design A growing seniors market has led the challenge. Speak with an demand for audiological services.. Eckel representative to out- With fierce competition audiologists line your customized must take measures to ensure their specialty requirements. clinic presents a welcoming and professional environment. Eckel Provides a Variety of Audiology Solutions Audio Booths, Rooms and Suites for Diverse Clinical Applications

AB Series Booths C/H & CL/HL Series S Series M Series MINI-BOOTHS ROOMS SUITES MULTI Pre-assembled and Eckel’s C/H and CL/HL Superb acoustic control Multi-station suites are ready to use AB Series Series rooms are the is attained through high ideal for group testing audiology booths offer gold standard of the performance double environments. The high performance in a audiology industry. walls, ceiling and floor series features high small package. Ideal for These premium quality, panels providing performance acoustic small footprint applica- innovative rooms offer a outstanding noise doors, fully isolated tions including medical wide range of options control. Suites are floors, custom interior offices clinical laborato- designed for precise available in double-wall wall coverings, carpeting ries, schools, business audiometric measure- designs for high ambi- and low noise ventila- and industrial settings. ment applications, ent noise applications. tion and air-condition- Booths are small enough including audiology, Flush sill acoustic doors ing systems. Options to fit through a standard medical offices, research feature a continuous include multi-glazed doorway while large institutes and more. The magnetic seal to main- observation windows enough to conduct series is ideal for tain acoustical integrity. and Low Profile door- testing. Unique in the industry and private Custom audiology ways. Designed for market for mini-size, clinics. All models have rooms can be tailored to multi-person testing, the acoustic integrity, a clinical jack panel for specific space require- Eckel M-series is appli- durability and utility. greater versatility. Ideal ments, and generally cable for baseline group Cam-Lock models are for sound field measure- include “Room within a testing and found in fully demountable. ments, brain stem Room” designs, which military and recruitment Choose from Cam-Lock audiometry, and hearing provide optimal acoustic offices, fire stations and & Fully Welded models. aid evaluation. isolation. various industries.

Eckel’s Unique Cam-Lock offers No other audiometric Did you Cam-Lock system flexibility in moving, room or booth on the connects and storing, and shipping market features this ? know? secures panels audiology systems. innovative design.

34 Eckel Noise Control Technologies Innovative Technologies to Better the Human Experience

Eckel USA Eckel Product Inquiries Eckel Canada 100 Groton-Shirley Rd. 1-800-563-3574 • 1-613-543-2967 35 Allison Avenue PO Box 776 Ayer, Massachusetts 01432 [email protected] Morrisburg, Ontario KOC 1XO [email protected] www.audiologyrooms.com Audiology Rooms

Find Your Local e3 Equipment Expert Toll-free 1-800-323-4371 [email protected] www.e3diagnostics.com

e3 Rep:

Eckel Noise Control Technologies • V:20200226