Price Research Center North

Total Page:16

File Type:pdf, Size:1020Kb

Price Research Center North PRICE RESEARCH CENTER NORTH The Most Extensive and Technologically Advanced Research and Development Air Distribution Test Lab in the HVAC Industry. www.price-hvac.com PRICE RESEARCH CENTER NORTH OVERVIEW PRCN at a Glance: 18,500 square feet 3 Fan Rooms 9 Testing Rooms 2 Sound Rooms The only one of its kind in North America, the PRCN (Price Research Center North) is a world class laboratory and testing facility that houses more than 18,500 square feet of state-of-the-art testing rooms, equipment and facilities! The newly expanded We have built a cutting-edge facility that gives our and upgraded PRCN is the customers the capability to customize test conditions latest example of Price’s continued and products in a real-time environment, resulting in commitment to research and development, accurate, reliable test data and interactive product providing the most reliable and accurate test data experiences. to the industry. It is Price’s ongoing commitment to the customer that PRCN is an excellent place for engineers, contractors, has driven this facility to become what it is today, architects and owners to view Price products operating the most advanced, extensive and comprehensive under a variety of installation and operating conditions. Research Center in North America! 2 CONTENTS 04 LAB LAYOUT LAB LAYOUT 06 CONTROLS DISPLAY & TRAINING ROOM TRAINING CONTROLS/ 10 TERMINALS & FAN COIL TESTING COIL TESTING TERMINAL/FAN TERMINAL/FAN 12 MOCK-UP ROOM 1 ROOM 1 MOCK-UP 14 FLOW VISUALIZATION ROOM FLOW FLOW VISUALIZATION 16 MOCK-UP ROOM 2 / THROW ROOM ROOM 2 MOCK-UP 18 REVERBERANT SOUND ROOM 1 SOUND ROOM REVERBERANT REVERBERANT 20 MECHANICAL EQUIPMENT EQUIPMENT MECHANICAL MECHANICAL 22 RADIANT TEST CHAMBER CHAMBER RADIANT TEST RADIANT TEST 26 NOISE CONTROL SOUND LAB LAB NOISE CONTROL www.price-hvac.com 3 PRICE RESEARCH CENTER NORTH LAB LAYOUT Mechanical Equipment Radiant Room Test Chamber Noise Control Sound Lab Controls Display 4 y &Training www. Mock-Up Room1 price-hvac .com Terminals & Fan Coil Testing &Fan Terminals Reverberant SoundRoom1 Room Flow Visualization Mock-Up Room2 5 NOISE CONTROL RADIANT TEST MECHANICAL REVERBERANT MOCK-UP FLOW MOCK-UP TERMINAL/FAN CONTROLS/ LAB LAYOUT SOUND LAB CHAMBER EQUIPMENT SOUND ROOM ROOM 2 VISUALIZATION ROOM 1 COIL TESTING TRAINING CONTROLS DISPLAY & TRAINING ROOM Price Controls The industry leader in custom controls, Price manufactures Benefi ts and Features: a comprehensive line of control solutions incorporating the latest BACnet technologies ranging from rooftop controls Controls solutions from rooftop to zone controls to motor controls to multiple zone controls. Whether your Industry leader in custom controls building is large or small, Price controls will meet the demands of your facility! Latest BACnet technologies available giving optimal system control Custom development of control solutions allow for the ultimate in fl exibility, giving customers exactly what they End to end solutions for optimal occupant comfort need for optimal performance for their specifi c requirements. Allows for customizable sequences resulting in the The use of BACnet technologies enables open system best possible performance strategy at all levels and ensures an end to end solution designed to deliver the ultimate in occupant comfort. What is BACnet? Price has chosen BACnet, the ASHRAE building automation and control networking protocol, for its products since it has many benefi ts. Some of the benefi ts of BACnet include: Low cost hardware allows networking almost any device Supports multiple LAN technologies (Ethernet/MSTP) BACnet is an ANSI/ASHRAE standard All networked Price products use the BACnet standard for communication, meaning all products will work together as a system without any special programming or protocol converters (gateways). This ensures reliable operation in the fi eld and allows the building owner to expand their system around a standard communication protocol. 6 www. price-hvac Features: industry. technologies andinnovations available intheHVAC available when itcomestoindustry fundamentalsandthelatest our expertswillensureyouexperiencethemostadvanced training multimediaandhands-onproductsamples, cutting edgevideo, Using Price ResearchCenterNortharegenuinelyworldclass. thepresentations andtrainingavailable at the in theindustry, With themostknowledgeable designandapplication engineers Room Training the industry The mostknowledgeable designandapplication engineersin innovations training onindustry fundamentalsandthelatest class World technology andproductdemonstrations The latest multimedia, .com 7 NOISE CONTROL RADIANT TEST MECHANICAL REVERBERANT MOCK-UP FLOW MOCK-UP TERMINAL/FAN CONTROLS/ LAB LAYOUT SOUND LAB CHAMBER EQUIPMENT SOUND ROOM ROOM 2 VISUALIZATION ROOM 1 COIL TESTING TRAINING CONTROLS DISPLAY & TRAINING ROOM PDRC (Price Digital Rooftop Controller) Price ECM Motor Controls The Price Digital Rooftop Controller is Standard Model designed for use with packaged rooftop Price ECM controls standard model is the equipment. This controller comes pre- economical choice. It is outfi tted with a local programmed and ready to use, eliminating dial adjust and a BAS (Building Automation the need for fi eld programming. System) built in, allowing for remote control It has a number of fi eld selectable control of the motors. A diagnostic LED blinks out strategies. This provides the fl exibility to modify the control strategy codes to tell the user what mode the speed controller is operating. post installation, ensuring optimal results. Deluxe Model The deluxe model comes with an illuminated digital display. The display supports easier fi eld adjustment, allowing the motor speed to be increased or decreased in 1% increments. This model also houses a BAS and an RPM output reading, allowing you to read the RPM of the motor. This is very benefi cial to identify problems that may be occurring BACnet ROUTER with the system, allowing for quick and effi cient trouble shooting. The BACnet Router allows the user to access systems all over the world from a remote location. This is an excellent tool for troubleshooting, remote monitoring The PIC (Price Intelligent Controller) and remote management for the system. This router can be used with any BACnet The PIC (Price Intelligent Controller) is device, it isn’t limited to rooftop controllers only, but can be used for Price’s own controller that supports the any BACnet system and controller. BACnet option, and soon to support pressure independent control. The PIC has several outputs to support virtually any control sequence. Each output has a pluggable terminal block for easier fi eld wiring and a diagnostic PEDC (Price Electronic Digital Control) LED to let the user know when the output is active. Thermostat hookup is quick and error proof with a standard RJ-45 cable. This reduces wiring errors and results in a quicker installation. The Price Electronic Digital Control is a To allow integration into a BACnet system, the PIC supports a plug and pressure independent zone controller play BACnet module. The BACnet module allows sharing data on a MS/TP with an LCD thermostat. system. It also allows the user to remotely adjust set points, trigger night setback for energy savings and monitor dozens of variables in the controller for easy troubleshooting and setup. For better airfl ow control the PIC supports a plug and play VAV module. The VAV module uses a MEMS (micro electromechanical system) fl ow sensor that is not sensitive to position and designed to survive dusty environments with no degradation in performance. Price Prodigy Smart Diffuser The prodigy smart diffuser is a pressure dependant modulating diffuser, available UMCII (Underfl oor Modulation Controller II) with the BACnet option. It has dual outputs for drone units and supports The Price UMCII has the ability to control an auxiliary reheat output allowing for up to 30 underfl oor dampers, making it the the control of any local hot water valve, largest capacity of any underfl oor controller radiant panels or electric heat. The in the industry. Diagnostic LED provides feedback on the status of reheat and It uses a thermostat signal to modulate all network communication. underfl oor dampers to control the fl ow of cool air The Prodigy has a PI (Proportional Integral) controller that constantly into the space. The UMCII is an excellent choice adjusts the damper and reheat to maintain optimal comfort. for cooling only applications. All outputs also have overload protection. 8 LAB LAYOUT TRAINING CONTROLS/ COIL TESTING TERMINAL/FAN TERMINAL/FAN ROOM 1 MOCK-UP FLOW FLOW VISUALIZATION ROOM 2 MOCK-UP SOUND ROOM UMCB (Underfl oor Modulating Controller Box) Price Silent Guard Heater Controller REVERBERANT Price’s UMCB is built for use with This controller comes with quiet underfl oor terminal units. It functions PCB (printed circuit board) relays the same way as the UMCII, but has instead of the typical standard EQUIPMENT a capacity of up to 12 dampers. It magnetic contactors. This makes MECHANICAL differentiates itself from the UMCII as the unit much quieter, resulting in it can be used with a fan and reheat greater occupant comfort. coils, because it has extra IO outputs to handle this. It has a diagnostic LED light that blinks out codes, communicating The UMCB’s plug & play damper connections are useful because the type of error or function it is experiencing. It also has an onboard there is no need for fi eld wiring with a screw driver. Instead of digitally fi ltered air board switch, resulting in reliable airfl ow CHAMBER
Recommended publications
  • Air Compressor Noise Control Air Compressor Noise Control
    AIR COMPRESSOR BY NOISE CONTROL USA AIR COMPRESSOR NOISE CONTROL AIR COMPRESSOR NOISE CONTROL Compressor are often noisy an effective solution is often required to suppress the noise emitted from them. Compressor noise is usually a nuisance because they are sitting on comparatively lightweight structures. The best way to soundproof and to reduce any noise from a compressor regardless of size is to enclose it within a Floor Mounted 4-Sided Soundproofing Acoustic blanket Enclosure. For best results the enclosure should be as large as possible to allow less heat buildup and also to be more effective at reducing the noise output from reaching other areas and acoustically isolating the Compressor to contain structure borne sound being transmitted from where it is mounted. Depending on the current sound levels of the Compressor and your noise reduction goals, an abatement solution can be determined. In most applications a soundproofing blanket enclosure will meet your sound reduction needs. This is a two to four sided soundproofing enclosure with or without a roof. Typically a frame and track is constructed to suspend the soundproofing curtain panels. The soundproofing blankets material is a composite material bonding mass loaded vinyl with an acoustical absorber and faced with a vinyl diamond stitched facing. Using our Soundproofing Acoustic Blankets to construct a 4-sided noise control solution will significantly reduce sound. The noise reduction to be expected is a range of 20 to 40 decibels. The better the construction, weight of blankets and amount of soundproofing acoustic blankets used (the surface area) all factor into your sound reduction numbers.
    [Show full text]
  • Suburban Noise Control with Plant Materials and Solid Barriers
    Suburban Noise Control with Plant Materials and Solid Barriers by DAVID I. COOK and DAVID F. Van HAVERBEKE, respectively professor of engineering mechanics, University of Nebraska, Lin- coln; and silviculturist, USDA Forest Service, Rocky Mountain Forest and Range Experiment Station, Fort Collins, Colo. ABSTRACT.-Studies were conducted in suburban settings with specially designed noise screens consisting of combinations of plant inaterials and solid barriers. The amount of reduction in sound level due to the presence of the plant materials and barriers is re- ported. Observations and conclusions for the measured phenomenae are offered, as well as tentative recommendations for the use of plant materials and solid barriers as noise screens. YOUR$50,000 HOME IN THE SUB- relocated truck routes, and improved URBS may be the object of an in- engine muffling can be helpful. An al- vasion more insidious than termites, and ternative solution is to create some sort fully as damaging. The culprit is noise, of barrier between the noise source and especially traffic noise; and although it the property to be protected. In the will not structurally damage your house, Twin Cities, for instance, wooden walls it will cause value depreciation and dis- up to 16 feet tall have been built along comfort for you. The recent expansion Interstate Highways 35 and 94. Al- of our national highway systems, and though not esthetically pleasing, they the upgrading of arterial streets within have effectively reduced traffic noise, the city, have caused widespread traffic- and the response from property owners noise problems at residential properties. has been generally favorable.
    [Show full text]
  • Construction Noise Control Products and Vendors Guidance Sheet
    Construction Noise Control Products and Vendors Guidance Sheet Revised: 16 July 2018 Distributed by: New York City Department of Environmental Protection (NYC DEP) The following is intended to provide guidance to construction contractors with respect to finding and selecting suitable construction noise control products. These products and vendors may be helpful to contractors for achieving compliance with the New York City Noise Code, and more specifically, with the Construction Noise Rules found in Local Law 113, Section 24-219, Chapter 28, Title 15 of the Rules of New York City which went into effect in July 2007. While there are similarities in the approach to construction noise control for all work sites, the specific measures and solutions need to be carefully selected and implemented correctly. In general, noise control measures can be applied at the noise source, along the pathway, or at the receiver (listener) directly. For these reasons, it is highly recommended that contractors discuss their situation with a qualified acoustical consultant as early as possible. It is always more cost-effective to design for good acoustics from the beginning rather than to rely on retrofit solutions when noise becomes a problem later. To aid in the selection of an acoustical consultant, links to several national professional societies are provided. The NYC DEP can also provide a list of consultants. This information is not an exhaustive list of noise control products and vendors. It is intended for guidance and informative purposes only, and should not be construed as an official endorsement of any product, vendor, or consultant by the City of New York.
    [Show full text]
  • Advanced Air and Noise Pollution Control VOLUME 2 HANDBOOK of ENVIRONMENTAL ENGINEERING
    Advanced Air and Noise Pollution Control VOLUME 2 HANDBOOK OF ENVIRONMENTAL ENGINEERING Advanced Air and Noise Pollution Control Edited by Lawrence K. Wang, PhD, PE, DEE Zorex Corporation, Newtonville, NY Lenox Institute of Water Technology, Lenox, MA Krofta Engineering Corp., Lenox, MA Norman C. Pereira, PhD Monsanto Corporation (Retired), St. Louis, MO Yung-Tse Hung, PhD, PE, DEE Department of Civil and Environmental Engineering Cleveland State University, Cleveland, OH Consulting Editor Kathleen Hung Li, MS © 2005 Humana Press Inc. 999 Riverview Drive, Suite 208 Totowa, New Jersey 07512 humanapress.com All rights reserved. No part of this book may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, microfilming, recording, or otherwise without written permission from the Publisher. All authored papers, comments, opinions, conclusions, or recommendations are those of the author(s), and do not necessarily reflect the views of the publisher. For additional copies, pricing for bulk purchases, and/or information about other Humana titles, contact Humana at the above address or at any of the following numbers: Tel.: 973-256-1699; Fax: 973-256-8341; E-mail: [email protected] This publication is printed on acid-free paper. h ANSI Z39.48-1984 (American Standards Institute) Permanence of Paper for Printed Library Materials. Cover design by Patricia F. Cleary. Photocopy Authorization Policy: Authorization to photocopy items for internal or personal use, or the internal or personal use of specific clients, is granted by Humana Press Inc., provided that the base fee of US $25.00 is paid directly to the Copyright Clearance Center at 222 Rosewood Drive, Danvers, MA 01923.
    [Show full text]
  • Reducing Exposure to Lead and Noise at Indoor Firing Ranges
    Reducing Exposure to Lead and Noise at Indoor Firing Ranges Several studies of firing ranges have shown that exposure to lead and noise Summary can cause health problems associated Workers and users of indoor with lead exposure and hearing loss, firing ranges may be exposed particularly among employees and in- to hazardous levels of lead and structors. Lead exposure occurs main- noise. The National Institute ly through inhalation of lead fumes or for Occupational Safety and ingestion (e.g., eating or drinking with Health (NIOSH) recommends contaminated hands) (see Figure 2) steps for workers and employ- [NIOSH 2009]. ers to reduce exposures. Exposure Limits Description of Lead Exposure OSHA has established limits for air- borne exposure to lead (see 29 CFR According to the Bureau of Justice Figure 1. Law enforcement officers 1910.1025*). The standard creates during shooting practice. Statistics, more than 1 million Fed- the action level and the permissi- eral, State, and local law enforce- ble exposure limit (PEL). The action ment officers work in the United below 60 µg lead/100g of whole blood level for airborne lead exposure is 30 [NIOSH 2009]. States [DOJ 2004]. They are re- micrograms per cubic meter of air quired to train regularly in the use of (µg/m3) as an 8-hour time weighted firearms. Indoor firing ranges are -of average (TWA). The OSHA PEL for Noise ten used because of their controlled airborne exposure to lead is 50 µg/m3 conditions (see Figure 1). In addition as an 8-hour TWA, which is reduced For noise exposure, the OSHA lim- to workers, more than 20 million ac- for shifts longer than 8 hours.
    [Show full text]
  • Technical Guide For: Noise Control – Engineering Controls, Work Practices, & Administrative Controls
    Technical Guide for: Noise Control – Engineering Controls, Work Practices, & Administrative Controls Table of Contents Noise Control Basics ..................................................................................................................................... 2 There are four basic principles of noise control: ........................................................................................... 2 Noise controls from OTI class 521 ............................................................................................................... 3 Noise controls from NIOSH ......................................................................................................................... 7 Noise Control: A guide for workers and employers ................................................................................... 13 Case Studies of Successful Engineering Control and Work Practices ...................................................... 138 Pallet Manufacturer Noise Controls Case Study ................................................................................... 138 Pallet Disassembly & Repair Facility Noise Controls Case Study ....................................................... 145 Metal Recycler Shaker Table Noise Controls Case Study .................................................................... 157 Case Study – Vacuum Pump Noise ...................................................................................................... 160 Edge Bander and Wood Grinder Noise Control Case Study ...............................................................
    [Show full text]
  • Dust and Noise Environmental Impact Assessment and Control in Serbian Mining Practice
    minerals Article Dust and Noise Environmental Impact Assessment and Control in Serbian Mining Practice Nikola Lilic *, Aleksandar Cvjetic, Dinko Knezevic, Vladimir Milisavljevic and Uros Pantelic Faculty of Mining and Geology, University of Belgrade, Djusina 7, 11000 Belgrade, Serbia; [email protected] (A.C.); [email protected] (D.K.); [email protected] (V.M.); [email protected] (U.P.) * Correspondence: [email protected]; Tel.: +381-11-321-9131 Received: 30 November 2017; Accepted: 15 January 2018; Published: 23 January 2018 Abstract: This paper presents an approach to dust and noise environmental impact assessment and control in Serbian mine planning theory and practice. Mine planning defines the model of mining operations, production and processing rates, and ore excavation and dumping scheduling, including spatial positioning for all these activities. The planning process then needs to assess the impact of these mining activities on environmental quality. This task can be successfully completed with contemporary models for assessment of suspended particles dispersion and noise propagation. In addition to that, this approach enables verification of the efficiency of suggested protection measures for reduction or elimination of identified impact. A case study of dust and noise management at the Bor copper mine is presented, including the analysis of the efficiency of planned protection measures from dust and noise, within long-term mine planning at the Veliki Krivelj and Cerovo open pits of the Bor copper mine. Keywords: dust and noise impact assessment and control; air dispersion modeling; AERMOD; noise mapping; SoundPLAN; mine planning 1.
    [Show full text]
  • EPA 450/2-77-022 Control of Volatile Organic Emissions from Solvent Metal Cleaning
    EPA-450/2-77-022 November 1977 (OAQPS NO. 1.2-079) OAQPS GUIDELINES CONTROL OF VOLATILE ORGANIC EMISSIONS FROM SOLVENT METAL CLEANING I U.S. ENVIRONMENTAL PROTECTION AGENCY 1 Office of Air and Waste Management Office of Air Quality Planning and Standards I,\ a0- Research Triangle Park, North Carolina 2771 1 328 1 I, RADIAN LIBRARY DURHAM, N.C. II i. This report is issued by the Environmental Protection Agency to report technical data of interest to a limited number of readers. Copies are available free of charge to Federal employees, current contractors anc! grantees, and nonprofit organizations - in limited quantities - from the Library Services Office (MD-35). Research Triangle Park, North Carolina 27711; or, for a fee, from the National Technical Information Service, 5285 Port Royal Road, Springfield, Virginia 22161. Publ ication No. EPA-45012-77-022 PREFACE The purpose of this document is to inform regional, State, and local air pol 1ution control agencies of the different techniques available for reducing organic emissions from solvent metal cleaning (degreasing) . Solvent metal cleaning includes the use of equipment from any of three broad categories: cold cleaners , open top vapor degreasers , and conveyori zed degreasers. A1 1 of these employ organic solvents to remove soluble impurities from metal surfaces. The diversity in designs and applications of degreasers make an emission 1imi t approach inappropriate; rather, regulations based on equipment specifications and operating requirements are recomnended. Reasonably available control technology (RACT) for these sources entails implementation of operating procedures which minimize solvent bss and retrofit of applicable control devices. Required control equipment can be as simple as a manual cover or as complex as a carbon adsorption system, depending on the size and design of the degreaser.
    [Show full text]
  • Quietzone® Quietzone® Acoustic Batts Acoustic Batts
    QuietZone® QuietZone® Acoustic Batts Acoustic Batts Product Data Sheet Product Data Sheet Sliding doors should be avoided Owens Corning offers a variety • Uniform Building Code (ICBO) performance desired. The STC • Lightweight and pre-cut where optimum noise control of duct systems, wraps and liners building types III, IV, and V performance data for various wall to 93" or 105" lengths for is desired. Doors opening on that effectively reduce noise. constructions can be found on quick installation and hallways should not open across • National Building Code pages 3 and 4. easy transportation. from one another. Fire Safety (BOCA) building types Kraft facing will burn. Do not 3, 4, and 5 Durable Composition • Faced batts are easily identifi ed Electrical leave exposed. Facing must be QuietZone acoustic batts: by attractive, PINK-kraft facing Light switches and outlets should • Standard Building Code featuring large images of the installed in substantial contact (SBCCI) building types • Are dimensionally stable. not be located back-to-back. with an approved ceiling, fl oor PINK PANTHER™. Ceiling fi xtures should be surface III, V, and VI. or wall material. Keep open • Will not slump over time. • Easily stapled and cleanly mounted and openings around fl ame and other heat sources Always check with your local boxes should be sealed airtight. • Are composed of inorganic fabricated to allow for away from facing. Do not place building code offi cial regarding improved workmanship and insulation within 3” of light local requirements affecting glass fi bers which do not Circuit breaker boxes, telephone absorb water. acoustical performance. outlets and intercom systems fi xtures or similar electrical installation of all building devices unless device is labeled should be located on well- components.
    [Show full text]
  • Speciality Organic Chemicals Sector (EPR 4.02)
    How to comply with your environmental permit Additional guidance for: Speciality Organic Chemicals Sector (EPR 4.02) Published by: Environment Agency Rio House Waterside Drive, Aztec West Almondsbury, Bristol BS32 4UD Tel: 0870 8506506 Email: [email protected] www.environment-agency.gov.uk © Environment Agency All rights reserved. This document may be reproduced with prior permission of the Environment Agency. March 2009 GEHO0BPIV-E-E Contents Introduction ............................................................................................................................2 Installations covered .............................................................................................................3 Key issues ............................................................................................................................5 1. Managing your activities ...................................................................................................9 1.1 Environmental performance indicators ...........................................................................9 1.2 Accident management ....................................................................................................9 1.3 Energy efficiency ............................................................................................................9 1.4 Efficient use of raw materials and water .......................................................................10 1.5 Avoidance, recovery and disposal of wastes................................................................11
    [Show full text]
  • Acoustic Design Criteria in Naturally Ventilated Residential Buildings: New Research Perspectives by Applying the Indoor Soundscape Approach
    applied sciences Concept Paper Acoustic Design Criteria in Naturally Ventilated Residential Buildings: New Research Perspectives by Applying the Indoor Soundscape Approach Simone Torresin 1,2,* , Rossano Albatici 1 , Francesco Aletta 3 , Francesco Babich 2 , Tin Oberman 3 and Jian Kang 3,* 1 Department of Civil Environmental and Mechanical Engineering, University of Trento, Via Mesiano 77, 38123 Trento, Italy; [email protected] 2 Institute for Renewable Energy, Eurac Research, A. Volta Straße/Via A. Volta 13/A, 39100 Bolzano, Italy; [email protected] 3 UCL Institute for Environmental Design and Engineering, The Bartlett, University College London (UCL), Central House, 14 Upper Woburn Place, London WC1H 0NN, UK; [email protected] (F.A.); [email protected] (T.O.) * Correspondence: [email protected] (S.T.); [email protected] (J.K.); Tel.: +39-0471055692 (S.T.) Received: 9 October 2019; Accepted: 6 December 2019; Published: 10 December 2019 Featured Application: Providing a new research perspective for the development of acoustic requirements in naturally ventilated buildings and of façade control strategies enabling NV. Abstract: The indoor-outdoor connection provided by ventilation openings has been so far a limiting factor in the use of natural ventilation (NV), due to the apparent conflict between ventilation needs and the intrusion of external noise. This limiting factor impedes naturally ventilated buildings meeting the acoustic criteria set by standards and rating protocols, which are reviewed in this paper for residential buildings. The criteria reflect a general effort to minimize noise annoyance by reducing indoor sound levels, typically without a distinction based on a ventilation strategy.
    [Show full text]
  • SIDERISE Marine Noise Control NC-2330 TDS V1 Nov15
    MARINE : NC-2330 MARINE NOISE CONTROL DATASHEET VERSION 1 : NOVEMBER 2015 SIDERISE® NC-2330 MARINE NOISE CONTROL A lightweight, moisture resistant, non-flammable acoustic treatment for marine engine rooms, delivering exceptional noise reduction bringing comfort to all on board. Application For marine vessels there is typically the following challenging requirements for insulation treatments: • Reduced weight • Confined space • Shallow depth partitions • High levels of low frequency noise • High aesthetic finish SIDERISE has over 40 years expertise in insulation solutions, including acoustics and noise control, thermal insulation and passive fire protection. SIDERISE NC-2330 Marine Noise Control has been engineered for minimum weight and thickness whilst still delivering sound reduction performance. Features Benefits • Excellent acoustic performance • Optimised for performance, weight and space saving • High aesthetic finish • Reduces noise issues on board, promoting comfort and protecting passengers and crew • Slim profile • Fire safety protecting lives and preserving vessels • Moisture resistance • Environmental protection, through fire safety, noise control • Lightweight core and thermal efficiency • Mechanical strength SIDERISE insulation solutions Rw 48dB • Over 40 years of expertise in insulation solutions EN ISO 717-1 : 2013 • Compliance and quality assurance • Bespoke solutions and advice • Design and specification service Acoustic, fire and thermal insulation specialists MARINE : NC-2330 MARINE NOISE CONTROL Acoustic performance
    [Show full text]